WARNING-Read instruction before operating this equipment
Contents
1. CALL CERVICE on the control panel When unit is on green light for POWER will be on and yellow light for LOW O2 PURITY will be on for several minutes before off Then green lights for NORMAL O2 PURITY will be on Description for purity indicating lights on the display as follow 1 Green light for NORMAL O2 PURITY on with LCD information Normal Oxygen output oxygen purity is normal and with purity higher than 85 2 Yellow light for LOW O2 PURITY on with LCD information Low Oxygen output oxygen purity is lower than acceptable 85 purity Once output oxygen purity is lower than acceptable 85 purity then green light for NORMAL O2 PURITY will be off and yellow light for LOW 02 PURITY will be on In this case switch to your alternate reserve oxygen sources Warning If purity keeps going down continuous siren alarms occur In this case contact your dealer Nebulization Instruction FOR NEBULIZATION TYPE ONLY Infuse liquid medicine into nebulization cup before starting nebulization Figure 5 a Connect the accessory tube with the output oxygen connector Liquid medicine in the nebulization cup starts to be nebulized although it is not very obvious enough Caution nebulization cup must be connected to output oxygen connector and it is prohibited to be connected with humidifier bottle Figure 5 b Press the nebulization button at the right side of the unit top for 5 seconds Fig
2. SPA treatment mode 2 2Press the SPA button nebulization button then the LCD shows Treatment mode Runtime 0000hr 2 3Adjust the flowmeter knob for suitable output pressure you need 2 4Now you can enjoy the skin oxygen SPA treantment 3 Pressure the SPA button again then the unit switched to Normal Mode again Circuit breaker reset button Your oxygen concentrator is equipped with a circuit breaker reset button to protect the electrical circuits from overload next to the power switch In the event of an overload the circuit breaker button will pop out To reset the circuit breaker please push down the button Turning the Concentrator off After using the concentrator for the time prescribed by your physician move the concentrator s power switch to the OFF position to turn off concentrator power Unplug the concentrator s AC connector from the power outlet 6 Transport the oxygen Concentrator The OXYBELL Oxygen Concentrator is equipped with a luggage handle and casters for transportation To transport the concentrator 1 Remove and store any accessories such as tubing cannulas masks and humidifier bottle if equipped 2 Fold and wrap the power cord and attach it to the concentrator cabinet using the strap Using the luggage handle Extend the luggage handle Pull the handle up completely Ensure that the handle is completely extended and securely in place Retract the luggage handle Lower the handle completely Ensure t
3. carton 2 Carefully remove all the components from the carton 3 Examine exterior of the oxygen concentrator for nicks dents scratches or other damages Inspect all components Note Unless the oxygen concentrator is to be used immediately retain containers and packing materials for storage until usage is required Caution To avoid any damage during transportation the compressor in the concentrator is fastened with belts Before using operate as follow 1 Upside down the machine gently 2 Cut off the fastening belts then pull them out and make sure no remains in the machine Storage Store the repackaged oxygen concentrator in a dry area DO NOT place anything on top of the repackaged concentrator Always store the concentrator upright to prevent damage Caution Ensure that the temperature at the concentrator s location during storage does not fall below 5 r exceed 70 C 4 Installation Installation location safety Information Select a well ventilated fume free room in your house where using the oxygen concentrator would be most convenient The concentrator can be easily moved from room to room on its casters To reduce the risk of electrocution fire explosion burns serious Personal Injury and or Property damage WARNING Keep the oxygen concentrator away from flammable and explosive areas WARNING To reduce the risk of fire special care must be taken when using an oxygen concentrator DO NOT SMOKE while using this devi
4. instruction Outlet connector Switch Flow regulating button o Flow meter Circuit breaker Indicating light for POWER Indicating light for NORMAL O2 PURITY For purity monitoring type only 9 Indicating light for LOW O2 PURITY For purity monitoring type only O N O O Oo o o a 9030 10 Indicating light for Maintenance Alarm 11 LCD screen 12 Nebulization cup For nebulization type only 13 Nebulization button For nebulization type only Figure 1 Back view Figure2 14 Maintenance entrance with Intake filter inside 15 Exhaust 16 External air filter 17 Power cord 5 Operation WARNING Read the safety section and operating instructions in this manual before use Preparation Attach appropriate accessories to the oxygen outlet Tubing Connection Figure 3 1 Thread the oxygen output connector onto the outlet 2 Directly attach the oxygen tubing to the connector Figure 3 Tubing Connection with Humidifier bottle Figure 4 WARNING The use of a humidifier bottle with a concentrator must be prescribed by a physician If you are prescribed to use a humidifier bottle as part of your therapy please follow these steps 1 Fill the humidifier bottle with distilled water up to the top mark pr WARNING DO NOT overfill the humidifier bottle pr 2 Thread the wing nut on the top of the bottle to the oxygen outlet e
5. of usage It is available from your local dealer Bacteria Filter HEPA The bacteria filter inside the oxygen concentrator micro disc should be replaced after each 15000 hours use Contact your dealer after this period Failure to follow above maintenance rules may result in damage of the oxygen concentrator and void the warranty 8 Troubleshooting The following troubleshooting chart can help you analyze and correct oxygen concentrator malfunctions If below suggested procedures do not work please switch to an alternate reserve oxygen source and contact dealer AX WARNING AGAIN DO NOT REMOVE THE CABINET UNLESS YOU ARE A QUALIFIED TECHNICIAN CHART OF TROUBLESHOOTING Symptoms Possible Causes Remedies ae i Cut off belts fastened the compressor When the switch is on unit Belts fastened the compressor are not i See operation in Section vibrates fiercely with loud noise cut off 3 Handling Unpacking Caution 1 Ensure that power cord is connected to the wall outlet 2 Ensure that there is power in the wall outlet 3 Ensure that an extension cord is not Concentrator power switch is on used but concentrator will not turn on 4 If the wall outlet is connected to a light Red LED illuminates No power to the device switch ensure that the light switch is nonflashing in the ON position Audible alarm sounds 5 Ensure that circuit breaker reset button is not popped out if so push it down 6 If conditio
6. so that the bottle is suspended Make sure it is firmly tightened i I i 3 Attach the oxygen tubing to the outlet of the bottle Figure 4 WARNING DO NOT reverse the oxygen inlet and output connections or water from the humidifier bottle will travel through the oxygen hose back to the patient Setup 1 Before proceeding ensure that all instructions in Section 4 Installation have been followed and that you have read the SAFETY section of this manual 2 Ensure that the concentrator power switch is in the OFF position Plug the concentrator s AC connector into the power outlet Turning the Concentrator on 1 Press the power switch to ON position The system starts running and the power light will illuminate 2 Turn the flowmeter knob to center the flowmeter ball on the LPM prescribed The flowmeter can be adjusted only after the unit is powered on NOTE Your supplier might have preset the flowmeter so you can skip this step 3 Now your oxygen concentrator is running Please choose the using time as prescribed A WARNING Improper use to the power cord and plug can cause buming fire or other electric shock hazards A WARNING Oxygen is flammable No smoking near the working oxygen concentrator 8 Purity Indicating FOR PURITY MONITORING TYPE ONLY Unique purity indicating function is available for purity monitoring type unit only There are four lights POWER NORMAL O2 PURITY LOW 02 PURITY
7. HIS DEVICE IS NOT INTENDED FOR LIFE SUPPORT Power interruption could prevent the device from operating User who requires continuous oxygenation must plan for alternate reserve sources of power and oxygen in the event of a failure or loss of power and oxygen Failure to observe the safety statements in this manual can result in severe fire property damage physical injury and or DEATH A Under certain diagnoses oxygen therapy can be hazardous use this concentrator only as prescribed by a physician A There are different accessories such as accessories include oxygen tubing humidifiers cannulas and masks that can be used with an oxygen concentrator Your physician or provider will recommend different types of accessories to be equipped with your oxygen concentrator OXYBELL accessories are available and recommended for use with the OXYBELL Oxygen Concentrator 2 Safety Information The safety statements presented in this chapter refer to the basic safety information the operator of the oxygen concentrator shall pay attention to and abide by There are additional safety statements in other chapters or sections which may be the same as or similar to the following or specific to the operations Please note the following special statements used throughout this manual and their significance DANGER Indicates an imminent hazard situation that if not avoided will result in death or serious personal injury WARNING Indicates a potential hazard
8. WARNING Read instruction before operating this equipment Oxy Bell K55 Oxygen Concentrator User Manual C WARNING Read instruction before operating this equipment CONTENTS Introduction 0xnnnnnnnnnnnnnnnnnnereernnnnnnerevevvnnnnnnnerevvvvnnnnnneeernnvnnnnnnnnernnnnnnnnnenenn 3 intended use Se ASA Adair 3 Safety Information xx xxnn00nnnnnnnnnnnnnrnnnervnnnnervvnnnrvnnnervnnnennvnnnrrvvnnnennnnevvnnnnnnnnnnn 4 Handling vannunnnnnunnvnunnnvnunnvnunnnvnunnvnnnnnnnnnnnnunnnnnnnunnnnnnunnnnnunnunnnnnnnnnnunnnnnnnnvnunnnnnnnnnnunnnnnnn 5 Transportation vannavarnanavnanavnnnanuvnanvannenannnnnnavnnnnnnnnnnannnnanannananannrnennenenevnnnennnnennnnnnenennnnn 5 Unpacking vannunnnnanannanannrnenennunnnnnnenavnrnanarnenennenennvnnnnnn nn enn nn nn er eer cree cere ee rrr errr err rrr rrr 5 Storage SrOCTCCLOCTOLeCSeTOCeererereererereer er ereer errr eer er erate rte rere ere rer eere rer rere rere errr ee ree er ee eee ee re eee ey 5 Installation xxsaa000000nnnnnnennnvnnnnnnnrernnnnnnnnerevnnnnnnnerevevnnnnnnrervvnnnnnnnrernnnnnnnnnnnnnn 5 Installation location safety informationoeveevevevevevenenennereneeereunnen 5 Radio frequency interference gt gt gt gt gt gt s tsrrrerrrrr nere trenere rer kreert keen 6 Product description vareranvenenunnnnvannnunnnnnnnennanevnnnennnnennnnennnnenannennnnenn uvnnnnnnnennnrnnnnvenner 7 Operation ree Pee O ORO e terre reer errr etre r rrr ererrer
9. ce Keep all matches lighted cigarettes and other sources of ignition out of the room in which this concentrator is located In public settings or when used in hospital or long term care environments prominently display NO SMOKING signs WARNING A spontaneous and violent ignition could occur if oil grease or greasy substances come in contact with oxygen under pressure ALWAYS keep these substances away from the oxygen concentrator and all other oxygen equipment WARNING Textiles and materials that normally would not easily burn can ignite and burn with great intensity in oxygen enriched air ALWAYS keep these materials away from the oxygen concentrator and all other oxygen equipment WARNING The oxygen concentrator is intended to be rolled from room to room Do not place the oxygen concentrator in surroundings where its airflow is obstructed WARNING Be certain to place the concentrator so that all sides are at least 30cm away from walls draperies furniture or other obstructions Do not place the concentrator in a confined area WARNING The oxygen concentrator MUST be kept away from heat fire flammable and explosive areas and excessive water sources and conditions Keep all oxygen tubing cords and oxygen concentrator away from heated or hot surfaces including space heaters blankets stoves and similar electrical appliances WARNING Do not use a household extension cord if the AC cord does not reach the power outlet Use of an extensio
10. d tap water If washed allow the filter to air dry before reinstalling it in the concentrator 4 Reinstall filter in concentrator Caution Do not operate the concentrator without the cabinet filter installed or while the filter is wet These actions could permanently damage the concentrator WARNING The cabinet filter shall be cleaned two times in the month or more often if it gets dirty Failure to follow this caution may cause permanent damage of the unit which results in the loss of warranty Cleaning the cabinet Clean the cabinet monthly or more often if it gets dirty or your environment is very dirty 1 Ensure that the power cord is unplugged and the power switch is at the OFF position 2 Clean the cabinet with a mild household cleanser and a clean non abrasive cloth or sponge WARNING Do not immerse the concentrator in water or other liquid Do not pour liquids on the concentrator while cleaning Do not allow any liquid to enter the concentrator Caution Many cleansers must be diluted before use Follow the manufacturer s directions carefully to avoid damaging the cabinet Replacement Parts Below replacement parts and accessories are available through your distributor or medical stores I Cannula tubing I Humidifier bottle Ill Oxygen mask Cannula Mask and Tubing Clean and replace the cannula mask and tubing as dealer s instruction Intake Filter The intake filter should be replaced after each 12 months
11. e prescription of a physician and this user manual DO NOT make adjustments to the flow rate unless prescribed by a physician WARNING If at any time you feel that you are not receiving the correct amount of oxygen contact your provider and or physician immediately WARNING DO NOT allow any powder or powder like substance near the oxygen concentrator and or its tubing the powder could cause contamination of the device and the possible resulting device malfunction could cause oxygen to drop to ineffective levels WARNING Supervise use of this device closely when it is used by on or near children or those who require extra care WARNING Always unplug this device immediately after use WARNING Do not leave this device unattended when it is plugged in Caution To reduce the risk of minor personal injury and or product property damages Caution During transport always keep the concentrator upright to prevent damage If the concentrator is transported in the trunk of a car ensure that the concentrator is secured so that it will remain upright Caution Ensure that the temperature at the concentrator s location during transport does not fall below 5 r exceed 70 C 3 Handling Transportation The oxygen concentrator should ALWAYS be kept in the upright position to prevent damage during transportation The OXYBELL packaging has been designed to assure maximum protection of the concentrator Unpacking 1 Remove all loose packing from the
12. hat the handle is completely retracted and securely in place Caution Do not lift oxygen concentrator by the luggage handle 7 Maintenance Clean the housing once in the month I Nasal cannula should be replaced every 3 months Ill Use only distilled water to the humidifier bottle All repairs and regular maintenance can be performed only by authorized OxyBell service Once a year the oxygene concentrator should go through periodic inspection in accordance with the manufacturer s service operation User maintenance DANGER The concentrator was specifically designed to minimize routine preventive maintenance Preventive maintenance or adjustments to the concentrator are to be performed only by authorized service personnel the performance of such maintenance or adjustment by any other personnel could void the warranty and create a hazardous condition or serious personal injury WARNING Ensure that the concentrator is unplugged from the AC power source and the power switch is at the OFF position before performing maintenance on the concentrator Cleaning the cabinet filter Clean the cabinet filter two times in the month or more often if it gets dirty or your environment has high dust or pollutant levels 1 Ensure that the power cord is unplugged and the power switch is at the OFF position 11 2 Remove the filter carefully from the rear of the cabinet 3 Vacuum the filter carefully or wash it with a mild detergent an
13. n cord could result in fire and electric shock WARNING DO NOT connect the concentrator in parallel or series with other oxygen concentrators or oxygen therapy devices WARNING DO NOT plug the concentrator into the same outlet as any other major appliance WARNING Always place the concentrator on a hard surface Never place the concentrator on a surface such as a bed or couch where the concentrator could tip or fall WARNING Do not place items on top of the concentrator WARNING NEVER block the concentrator s air openings WARNING Keep the concentrator openings free from lint hair etc Caution The concentrator should be appropriately placed to keep it from falling strong vibration or other mechanical damage Caution Only use stable and safe electrical power sources Caution Do not pull the oxygen concentrator by the power cord Caution If the oxygen concentrator has been subjected to sub freezing temperatures for an extended period of time allow it to warm up to the stated operating temperatures before power up Failure to do so could result in improper performance and or alarm conditions until the device reaches normal operating temperatures Radio frequency Interference Most electronic equipment is influenced by Radio Frequency Interference RFI ALWAYS exercise caution with regard to the use of portable communication equipment in the area around the oxygen concentrator Product description Front view Figure1 Operating
14. n persists contact your OXYBELL authorized distributor for repair 1 Inspect tubes and cannula to ensure that they are not kinked or blocked Smooth tubes to unblock 2 Check humidifier bottle if so equipped for Concentrator works but little or i yen Possible blockage leaks or jamming Remove humidifier bottle no oxygen from outlet i clean with warm soapy water rinse reinstall and tighten 3 If condition persists contact your OXYBELL authorized distributor for repair Flowmeter ball located on 0 Adjust flowmeter knob If condition persists position or flowmeter float is Possible flowmeter problem Contact your OXYBELL authorized unstable distributor for repair 9 Specifications Power Consumption 300 W Applied Voltage AC 230V 50 60Hz Size Weight Outlet Outlet Pressure Flow Rate Oxygen Purity Noise Storage Condition 305x300x610 LxWxH mm 14 5 kg 1 0 04 0 06 MPa 0 5 LPM 93 3 40dB A temperature 5 C to 70 C humidity lt 80
15. r ttt eee t deretter 11 Cleaning the cabinet varesnnnavnanentvnnnnanvenennnnannennnnnnnnnennnnennnvnnnenannannnrennnvannennnnenner 12 Replacement parts Perro reer errr Terre reer rere Terre reer reer eer cere ere ere ere rere errr er eer reer er eee ree rere eee 1 2 Cannula mask and tubing vavavnnvannnnannennnnnnnenannennnnnnnnnnnnennnvannenannnnnevannennnvannennnr 12 Intake Filter varesnnnenavnnnnnnnnvannnnnnnnnvanenennnnnnnnnnnnnnvannannanannannnrnnnnnennnnnnnenn eee eee ere 12 Bacteria Filter Peer reece reer er eer eee rere reer reer cere creer reer er eer ee ere eee eee eee e rece ee eee eer er ere 12 Troubleshooting Prete eter ere re tree er ererrrerrr rer rrrerrererrertrererr rier rier ere rrr tr rere terre trite 13 Specifications ree ee Creer ere terre errr re terete rer tr rrerrrrertrrrerrrrrrertrrrerrrrertrtretirerrrer retiree 14 1 Introduction This user manual contains important information and safety precautions for the OXYBELL Oxygen Concentrator Before using your oxygen concentrator please read and understand this entire user manual Save this user manual for future reference Intended use of this device The OXYBELL Oxygen Concentrator is intended for being used as an oxygen supplement device in household or care facility Use the concentrator only as prescribed by a physician This user manual serves as a reference for your oxygen concentrator Take special note of all safety precautions marked DANGER and WARNING WARNING A T
16. rrerrererrrrrrerrerererrtrerrrrrrererrerrrrrrererr rrr rirerr 8 Preparation eee Oe eee eter erate rer er eter errerrrrrrerererrirerrrererrerererrrrrrrrerrirr tre rirere 8 Tubing connection OPEC PPPT PLCC e eee eee ee reece eee ere eT ee reece errr ere rece e rere eee ere cere ee eee eee ere eee 8 Tubing connection with humidifier bottle if needed 8 Setup POPP PC eee eCecer errr eee r rere rere rr eer rrr er rere r errr r errr ere reer eer reer er ee eer eee rere reer rere eee ree eer ee eee 8 Turning the concentration ON OTTO EE 8 Purity indicating for purity monitoring type Only se 9 Nebulization instruction for nebulization type only jevvvvevevevenevennnnenennnnun 9 SPA Treatment for SPA type only eee eee eee eee eee ee eee rey 10 Circuit breaker reset button Perr er eee reer errr ree rere rere errr errr ee reer eee rere eee reer errr re ere eee ere eee 10 Turning the concentrator off Perr eer errr rere reer errr rere reer ere ere rer eer ere reer reer eee eee ee eee rere er er ery 10 Transport the oxygen Concentrator srrrrrrrrrrsrssssssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 11 Using the luggage Handle rr rrr ies 11 MaintenancCe xs0000n0nnnnnnnrnnnnnerernnnnrervnnnervvnnnrrvnnnnnrvnnnnnenvnnnnenvvnnnernnnnnrennnnnnnnnnr 11 User Maintenance varsvrnanenannanvanvnnnnavnnnnnvnnnnnnnnnnnensnnnnnnnnannanvarnnrnrannnvvnnnevnr nn nrenvansener 11 Cleaning the cabinet filter gt gt gt gt gt seessrrreeeer
17. situation or unsafe practice that if not avoided could result in death or serious personal injury Caution Indicates a potential hazard or unsafe practice that if not avoided could result in minor personal injury or product property damage DANGER _ To reduce the risk of electrocution fire and or explosion DANGER Do not use this device while bathing If continuous usage is required by the direction of a physician the concentrator must be located in another room at least 3m from the bath DANGER Do not place or store this device where it can fall or be pulled into a tub or sink DANGER Do not place this device in or drop it into water or other liquid DANGER Do not reach for a device that has fallen into water unplug it immediately DANGER DO not contact with the oxygen concentrator when you are wet DANGER The oxygen concentrator contains no serviceable parts do not open the cabinet Opening of the concentrator cabinet by anyone other than authorized service personnel could void the warranty and create a hazardous condition which could result in death or serious personal injury DANGER Avoid creation of any spark near the oxygen concentrator This includes sparks from static electricity created by any type of friction WARNING __To reduce the risk of burns and or serious personal injury WARNING Use this device only for its intended use as described in this manual WARNING This device is to be used only in accordance with th
18. ure 6 and then release when you hear a beep Now the nebulization is on with LCD nebulization indication Figure 7 and the visual effect is obvious The ball in the flow meter will drop to the bottom Figure 6 Figure 7 C Once the potion in the nebulization cup runs out press the nebulization button as well for a few seconds and release after a beep sound Now nebulization is off Remove the nebulization cup and make the unit running in normal condition CAUTION The nebulization Mode must be used with a nebulization cup The output pressure will be higher when the nebulization Mode starts so please do not inhale oxygen directly without nebulization cup SPA Treatment FOR SPA TYPE ONLY For SPA type unit it has two functions of normal mode oxygen inhalation mode and SPA treatment mode cosmetic SPA treatment 1 Normal Mode When you switch on the unit the LCD shows Oxybell 02 concentrator After 3 seconds it shows NORMAL MODE Runtime 0000hr 1 1 thread the humidifier bottle or oxygen outlet connector to the unit oxygen outlet port 1 2 connect the oxygen inhalation tubing with the humidifier bottle or oxygen outlet connector 1 3 put on the oxygen inhalation tubing and enjoy the oxygen inhalation 2 SPA Treatment Mode The unit also has the function of cosmetic skin oxygen SPA treatment If you need this just do as following 2 1Connect the SPA tubing with the unit and airbrush Caution do not use the humidifier bottle for
Download Pdf Manuals
Related Search
Related Contents
mesdocs2.rpn.ch - Service informatique du S2 Delta 9959-AR-DST Installation Guide 5RFWS1 iiyama ProLite B2209HDSD-B1 C-Series User's Guide - Bottomline Technologies DMV-1600 NTSC 取扱説明書 3. Stoccaggio, preparazione, montaggio Type 1872 a b a b a b a a b a b ENGLISH en Operating Instructions Manual de instruções Copyright © All rights reserved.