Home
225IR108V01002 LPC2 IR1V UsrMan
Contents
1. SMARTEH LIVING SYSTEMS USER MANUAL Longo programmable controller LPC 2 IR1V special module Version 2 SMARTEH d o o Trg tigrovcev 1 5220 Tolmin Slovenia Tel 386 0 5 388 44 00 e mail info smarteh si www smarteh si _ a Longo programmable controller LPC 2 IR1V special module SMARTER LIVING SYSTEMS Written by SMARTEH d o o Copyright 2012 SMARTEH d o o User Manual Document Version 002 July 1 2012 e a ongo programmable controller LPC 2 IR1V special module SMARTER LIVING SYSTEMS STANDARDS AND PROVISIONS Standards recommendations regulations and provisions of the country in which the devices will operate must be considered while planning and setting up electrical devices Work on 230 VAC network is allowed for authorized personnel only DANGER WARNINGS Devices or modules must be protected from moisture dirt and damage during transport storing and operation WARRANTY CONDITIONS For all modules LONGO LPC 2 if no modifications are performed upon and are correctly connected by authorized personnel in consideration of maximum allowed connecting power we offer warranty for 24 months from date of sale to end buyer In case of claims within warranty time which are based on material malfunctions the producer offers free replacement The method of return of malfunctioned module together with description can be arranged with our authorized represent
2. A Data receive send line A K1 4 Standard RS485 B Data receive send line B Table 3 LEDs amp Buttons Rx Serial comm status On RS 485 data receive aan color green Off no data present Tx serial comm status On RS 485 data transmit LED2 color tree Off no transmit LED3 IR comm status On correct IR request present color orange Off no IR request incorrect IR request Table 4 S1 RS485 ADDRESS Switch 1 Switch 2 0 OFF OFF 1 OFF ON 2 ON OFF 3 ON ON Module connects to the MCU unit on its RS485 port using interconnection cable e g SSK 7 When more special modules e g LPC 2 I1D1V LPC 2 ID2V LPC 2 P01V are connected to MCU splitter is also required e g SPL 2 Interconnection cable can ordered from Smarteh or terminated on site considering wiring scheme bellow Cable AWG26 4C flat __ SS ook WN Rj12 6pin M plastic notch faced Figure 4 Interconnection 6 cable SSK Rj12 6pin M pin faced NOTE Signal wires must be installed separately from power and high voltage wires in accordance with general industry electrical installation standard _ a ongo programmable controller LPC 2 IR1V special module SMARTER 7 3 LIVING SYSTEMS 3 2 Mounting frame selection Frame suitable for IR1V module insertion should be modular one at least 1 gang wide Be careful to have corresponding
3. ariable name Heart bit IR1V_x_HEART IR Code IR1V_x_IR_CODE IR Data IR1V_x_IR_DATA Heartbeat bit is reserved for checking that the device is still communicating correctly with the controller bit toggles on off every successful communication cycle with controller IR Code is the code received from remote control unit IR Data describes which button was pressed on the given remote control unit IR transceiver accepts commands from remote control unit only if IR Code and IR Data both match with the code and data stored in transceivers EEPROM When command is accepted red LED is lit for a short period of time 4 3 Transmit mode In this mode the device can transmit data over IR communication to some other IR receiver Data to be transmitted must be present on variables IR1Vx_IR_CODE and IR1Vx_IR_DATA Data is sent only if both variables are different than zero Same data is sent over and over again until at least one of these two variables is equal to zero 4 4 Universal Remote control unit programming The easiest way to program the remote control unit to work with IR transceiver is to start the automatic search mode refer to your remote control unit user manual for instructions on how to do this and point the remote in the direction of IR transceiver Automatic search will try to communicate with IR transceiver using all possible protocols When the correct protocol is used red LED on the IR transceiver lits up otherwise the LED is o
4. ative Warranty does not include damage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection scheme in this manual Misconnections may result in device damage fire or personal injury Hazardous voltage in the device can cause electric shock and may result in personal injury or death NEVER SERVICE THIS PRODUCT YOURSELF This device must not be installed in the systems critical for life e g medical devices aircrafts etc If the device is used in a manner not specified by the manufacturer the degree of protection provided by the equipment may be impaired ST Waste electrical and electronic equipment WEEE must be collected separately LONGO LPC 2 complies to the following standards e EMC EN 61000 6 2 EN 50082 EN 61000 6 4 EN 50081 e LVD IEC 61131 2 e Vibrations and climatic mechanical EN 60068 2 6 EN 60068 2 27 EN 60068 2 29 Smarteh d o o operates a policy of continuous development Therefore we reserve the right to make changes and improvements to any of the products described in this manual without any prior notice MANUFACTURER SMARTEH d o o Trg tigrovcev 1 5220 Tolmin Slovenia _ a _ Longo programmable controller LPC 2 IR1V special module SMARTER LIVING SYSTEMS Index Longo programmable controller LPC 2 IR1V special module T ABBREVIATION Satine acc
5. avior is needed For further information on adapting preprogrammed actions contact manufacturer Switching between the two ports is done automatically by the circuit and requires no user interaction Module works with universal remote control unit which support Infra red Protocol Sanyo 7461 carrier 38 kHz coding Pulse position modulation Power is supplied from LPC 2 MC7 LPC 2 MC8 controller through RS 485 cable therefor no additional power supply is needed lt 1 Longo programmable controller LPC 2 IR1V special module 5 2 FEATURES Table 1 Features SMARTTEH Figure 1 LPC 2 IR1V module LIVING SYSTEMS Programmable IR Transceiver Compatible with universal remote control unit Provides additional direct connection with PC RS 232 Store for 15 different predefined keys codes DIP switch configurable RS485 address Status LEDs for IR and RS 485 communication Modular frame mounting SMARTTEH LIVING SYSTEMS lt lt 1 ongo programmable controller LPC 2 IR1V special module 3 INSTALLATION 3 1 Connection scheme Figure 2 Connection scheme wees UNIVERSAL REMOTE 77 CONTROL Figure 3 Layout of LEDs Pushbuttons connectors a ongo programmable controller LPC 2 IR1V special module SMARTER Table 2 K1 LIVING SYSTEMS K1 1 GND Ground K1 2 9 VDC Power supply input K1 3 Standard RS485
6. ble 5 Technical specifications Power supply from MCU Interconnection connector type RJ12 6 6 Power consumption 0 5 W Dimensions W x H x D 24 x 48 x 34 mm Weight 15 g Maximum altitude 2000 m Mounting position all directions Ambient temperature 0 to 50 C Ambient humidity max 95 no condensation Transport and storage temperature 20 to 60 C Protection class IP 20 10 Longo programmable controller LPC 2 IR1V special module SMARTER 3 LIVING SYSTEMS 7 CHANGES The following table describes all the changes to the document Date V Description 1 7 2012 002 CGP General update 28 2 2008 001 The initial version issued as LPC 2 IR1V special module UserManual 11 lt Longo programmable controller LPC 2 IR1V special module SMARTER LIVING SYSTEMS 8 NOTES
7. e to the provided leveled place on the wall 2 Fasten 2 screws DIN 7981 or similar 3 mm max head height 3 mm to fix LPC 2 P01 module to its place 3 Connect interconnection cable to the interconnection connector K1 Max allowed tractive force is 30 N Set the correct RS485 address S1 switch for LPC 2 IR1V refer to the Table 4 Power PWR green LED should switch on according to the Table 5 Mount LPC 2 P01 module front plate to the back plate oe eS Fasten the screw in the bottom carefully not too strong to fix the front plate to the back plate e _ a ongo programmable controller LPC 2 IR1V special module SMARTER LIVING SYSTEMS 4 HOW TO USE 4 1 Addressing Depending on number of additional devices attached to 485 port of MCU corresponding address must be set properly as advised by LPC Composer application Address is set using DIP switches on the back side of module Refer to Table 4 for finding the corresponding position of slides advised by LPC Composer When address is changed device must be disconnected from the power supply and then reconnected again for changes to take effect After successful address configuration device is ready to communicate with controller 4 2 Receive mode In this mode the device accepts commands from remote control unit and forwards them to the controller over RS 485 network By default the following buttons on universal remote are recognized by the device numerica
8. ff At that time stop the auto search and store the last used protocol so that it will be used for all further communication The other way is to manually enter the correct code in the remote control unit Search your remote control unit user manual for protocol code which corresponds to general Samsung DVD device Enter that code in the remote and the unit should start communicating with IR transceiver _ a ongo programmable controller LPC 2 IR1V special module SMARTER LIVING SYSTEMS 5 MODULE LABELING Figure 7 Labels LPC 2 IR1V P N 2251R108V01001 D C 40 08 S N IR1V S9 0800000003 Label description LPC 2 IR1V is the full product name P N 225IR108V01001 is the part number 225 general code for LPC 2 product family IR1 short product name 08 year of code opening V denotes flush frame mounting module 01 derivation code 001 version code reserved for future HW and or SW firmware upgrades D C 40 08 is the date code 40 week and 08 year of production S N IR1V S9 0800000003 is the serial number IR1V short product name S9 user code test procedure e g Smarteh person xxx 08 year last two cyphers 00000003 current stack number previous module would have the stack number 00000002 and the next one 00000004 ongo programmable controller LPC 2 IR1V special module SMARTER 5 LIVING SYSTEMS 6 TECHNICAL SPECIFICATIONS Ta
9. flush mounting box provided on the place where module will be positioned Smarteh has verified following lines to be compatible with LPC 2 IR1V module Bticino Living Light Gewiss Playbus System Vimar Plana Idea Tem Master Frames of other vendors most probably suits as well but they were not verified by Smarteh Before installation verify compatibility of non listed frames Module housing has a fin on each side which can be easily removed with knife cutter or pliers This adaptation enables housing to be inserted in various frame formats With regard to frame used you may remove fin for housing to fit in Figure 5 Fin removing Longo programmable controller LPC 2 IR1V special module SMARTER LIVING SYSTEMS 3 3 Mounting instructions Figure 6 Housing dimensions EN wee PE TT Tooo oP ata 24 m B EPR e Dimensions in millimeters All connections module attachments and assembling must be done while module is not connected to the main power supply room It is advised to avoid direct sunlight or position near heating cooling source object Round flush mounting box e g Gewiss GW 24232 60 mm is recommended for installation A box must be installed with screw holes in the horizontal position The LPC 2 IR1V module should be positioned on the wall inside the Mounting instructions 1 Mount LPC 2 IR1V module back plat
10. l buttons from 0 to 9 program up and program down buttons reverse and forward buttons and power button Actions on these buttons are mapped to the LPC Composer variable in the way that is shown in the following table Table 5 Button mapping Remote control Default variable name Numerical button 1 IR1V_x_NUM_1 Numerical button 2 IR1V_x_NUM_2 Numerical button 3 IR1V_x_NUM_3 Numerical button 4 IR1V_x_NUM_4 Numerical button 5 IR1V_x_NUM_5 Numerical button 6 IR1V_x_NUM_6 Numerical button 7 IR1V_x_NUM_7 Numerical button 8 IR1V_x_NUM_8 Numerical button 9 IR1V_x_NUM_9 Numerical button 0 IR1V_x_NUM_0O Power on off button IR1V_x_PWR Program up button IR1V_x_P_UP Program down button IR1V_x_P_DOWN Reverse button IR1V_x_REV Forward button IR1V_x_FWD letter x can be any valid RS 485 address number between 0 and 3 When a button is pressed on the remote corresponding variable is set and send to the controller If e a _ Longo programmable controller LPC 2 IR1V special module SMARTER LIVING SYSTEMS the communication is successful the variable is automatically cleared after the answer is received from controller If a button is pressed and held corresponding variable is set and remains set until the button is released Beside actual buttons state IR transceiver also sends some other data to controller Table 6 Other sent received data Data Default v
11. us den seen ea den cs see ae aies 1 Z DESCRIPTION ae E 2 BOP EA ORE 3c a a ET 3 A INSTALLATION eee neee nennen ed en cs E E 4 Al CONNECTION SCHEIN G jenccescostswcuasoeessscasanustaccteesesenss nennen 4 4 2 Mounting frame selection ccc cece cece ccc ses 6 4 3 Mounting INStFUCTIONS sore srasvsrverrnserrevversseseerderseonssinnde neten 7 SHOW OUSE ennen en de ae ee en a EE 8 De ACCESS INS ne oo es ane ee a ee as ae Dee ce ee Ce cn cine co 8 DZ ROCOIN Gr MOGEN er ene 8 De TFANSIIC AA CIO LE PP PP ys cosauee E A EE E 9 5 4 Universal Remote control unit programming 9 SO MOUULE LABELING soensennbenrrsberei benee sc ERE antes 10 7 TECHNICAL SPECIFICATION S etste theses eed 11 o CHANGES ee 12 I NOTE ea a E E E E E E E A E E os 13 7 3 jii e a ongo programmable controller LPC 2 IR1V special module SMARTER LIVING SYSTEMS 1 DESCRIPTION LPC 2 IR1V is infra red IR transceiver module It enables remote controlling of various devices connected to LPC configuration Module accepts commands from remote control unit RC and forwards them to the controller It is then the application loaded in the MCU where logic is carried out e g button Up triggers light dimming Module communicates to the controller by RS 485 protocol Module features additional RS 232 port for communication with PC This port enables binding and Storing desired IR commands buttons to application variables when custom beh
Download Pdf Manuals
Related Search
Related Contents
Haier HB22FWRSSAA side-by-side refrigerator Integral INSSD64GP18MXZ solid state drive Q-Logic SANBOX User's Manual 415-CE ADITIVO REDUCTOR DE AGUA - kleer Denver MT-758, 7" portable DVD player Teledyne 6750 User's Manual TP-Link TL-SG3216 V1 Declaration of Conformity Technical manual for Multi Apartment Gateway 1456B Manual de Usuario Copyright © All rights reserved.