Home

Instruction leaflet digital furniture lock M300

image

Contents

1. OPERATING INSTRUCTIONS M300 SV SimonsVoss G2 Contents General description and mode of operation Information on operation and care Page 2 Components needed pack contents meer Page 3 Getting started changing batteries function check Page 4 Advice OM INSIANALON zu cs sa eseme Aka aaa Page 5 Advice on removal and technical information Page 6 Light indicators and signals u be 4 00 ww au wd tw we a ew a oe Page 7 Safety precautions The bolts can produce a maximum force of 5 10 N Exceeding this load may permanently damage the system Do not press the extended main bolt back into the casing by mechanical means This may cause damage to the lock motor On changing the batteries ensure correct battery polarity and position Dispose of spent batteries in the proper manner Do not heat batteries take them apart or short circuit them Never throw batteries into fire The batteries must not be charged Keep batteries out of children s reach Any person swallowing batteries must seek immediate medical advice Damaged and or leaking batteries may cause acid burns and or poisoning Page 1 BDA M300 SV GB Rev 02 23 06 2014 General description The M300 electronic locking system is an electronic furniture lock It is intended for indoor use in the home and office Using the system in applications for which it is not intend
2. abrasives or solvents such as glass thinner alcohol benzene or ammonia as they may react adversely with the enclosure Treating any of the electronic and mechanical components improperly or in any way other than described in this user manual may lead to malfunctions Page 2 BDA M300 SV GB Rev 02 23 06 2014 Components needed pack contents E Box M300 SV 3x 1 5V AA M Box M300 Indicator unit Operating instructions 3 point with cable nn i i d Re f 4 2x Spax 3x13 2x Spax 3x30 i System components Dimensions 145 8 28 5 Fixierung Page 3 BDA M300 SV GB Rev 02 23 06 2014 Getting started installation The motor unit electronics and indicator unit are not interconnected on leaving the factory To obtain a functional unit please carry out steps 1 to 3 see below one after the other After establishing proper working order disconnect the indicator unit picture 2 from the system again so that the system can easily be installed in furniture Q D tm Before installing the system insert the batteries into the control electronics and program the furniture lock as described in the system manual from SimonsVoss AG After programming make sure the system works properly Only install the furniture lock in furniture in an unlocked state In in hangin ri serting changing batteries Change batteries Make sure they are fitted the right way round Undo screw y Close lid g y gpen b
3. attery compartment lid Fit fixing screw Battery type ey Pv LR6 AA alkaline NOTE NiCd NiMH or other rechargeable batteries as well as zinc carbon or lithium batteries must not be used Checking for proper operation with an authorised transponder l Press button to unlock t Press button to lock Bolts extend Bolts retract Page 4 BDA M300 SV GB Rev 02 23 06 2014 Advice on installation This M300 is a motor driven lock with 3 point locking system This means that three bolts simultaneously move out of the casing The two side push bolts are normally connected to push bars This makes it possible to re position the locking points See installation drawing The accessories required push bars bar guides striker plates and fixing material are not included in the set and may be obtained from your fittings retailer To determine push bar lengths please use the length calculation method shown in the drawing This example shows a side hung door for furniture Installation dimensions Stangenlangenberechnung All dimensions in mm 4 554 A 5 4 Stangeniange A bar length Lichbes Innermall internal height B 53 B 53 B Slangenl nge bar length The indicator unit should be installed in such a way as to provide a good line of vision If you install the indicator unit physically separated from the control electronics the cable connecting these system compon
4. cess to specific items of furniture As a result entire locking systems with different access levels can be configured without a problem Each electronic control unit in the M300 system works autonomously without being connected by cable to other control electronics or the power supply system You can program different transmitters with ease in each electronic control unit In normal operation the control electronics only respond to the transponders programmed Please note The distance between the furniture locks must be at least 50 cm To operate the system you will also need a transponder from SimonsVoss AG that is already in your possession or which you may purchase from your supplier or retailer Note Our locks and locking systems can basically be used together with mechanisms made by other manufacturers but their compatibility must be checked by the processor in each individual case We cannot accept any liability for damage or losses due to incompatibility Advice on operation and care Do not pour any liquids into or over any of the system s components and never immerse the components in liquids Transmission reception range as well as reception quality may be affected by the building s structure sources of electronic interference or superimposed frequencies The receiver should not be exposed to direct sunlight Clean the system with a clean soft damp cloth only Do not use any cleaning products containing
5. ed may result in irreparable damage to it and render any claims null and void The user manual tells you how to install and operate the M300 system in the proper manner To program the furniture lock you will need the management software as well as the requisite hardware from SimonsVoss Technologies AG in Munich The M300 system can be tailored to your personal requirements as it is very easy to use It can be upgraded from a stand alone system into a complex convenient locking system and integrated into existing locking systems from SimonsVoss Technologies AG Wording and graphics have been prepared for you with care We are however unable to accept any liability for any errors that may nevertheless have occurred Copyright 2014 by LEHMANN Vertriebsgesellschaft mbH D 32429 Minden All rights reserved These instructions must not be reproduced in any way print photocopy microfilm or other process or processed duplicated or distributed using electronic systems either in whole or in part without written consent from LEHMANN Vertriebsgesellschaft mbH The scope of items included by the manufacturer in the system as well as technical specifications are subject to change without notice Operating description The M300 electronic locking system provides you with a convenient means of locking and unlocking your furniture electronically The 300 system allows you to issue selective access authorisations so that only authorised personnel is given ac
6. ents must not be longer than 1 m Please refer to the fitting instructions from the manufacturer of your furniture for the correct way to attach the M300 system to your furniture If you have any questions concerning system installation contact a firm of cabinetmakers or your supplier before commencing installation Page 5 BDA M300 SV GB Rev 02 23 06 2014 Advice on removing the M300 At some time or other it may be necessary to remove the M300 To do this please proceed as follows 1 Remove the fixing screws from the motor unit 2 Release the motor unit and electronics as shown and described below 3 Open the battery compartment lid take out the batteries and remove the fixing screws Push in T stick and hold in place Pull motor unit in direction of arrow Technical specifications To operate the system there must be a line of vision between transponder and receiver The distance between the furniture locks must be at least 50 cm Frequency 25KHz Be sure to observe national legislation on permissible wireless frequencies Reach approx 30 cm Transmission reception range may be affected by the building s structure To program and start the system please refer to the system manual from Firma SimonsVoss Technologies AG Power supply for control electronics battery type 3x AA mignon cell alkaline 1 5V NiCd NiMH or other rechargeable batteries as well as zinc carbon or lithium batteries must not be used Tempe
7. rature range operation 5 C to 40 C in 30 to 80 relative air humidity non condensing In storage 25 C to 70 C in 30 to 80 relative air humidity non condensing Mechanical load limits The front main bolt has a maximum thrust of 10N The two side push bolts have a maximum thrust of 5N each when evenly loaded All other aspects are subject to the technical information and regulations issued by SimonsVoss Technologies AG in Munich Page 6 BDA M300 SV GB Rev 02 23 06 2014 Light indicators and signals flashingt flashing Light indicators in normal operation on locking and unlocking EEE i Indicator Indicator Pause of Lock approx 1 Lock is engaged second Pause of Unlock approx 1 Lock is opened second Lock is opened but transponder battery is spent Contact q D GED WS amp Sarvice Warning indicators on locking The transponder is not Unauthorised authorised at transponder this lock and is rejected No locking C action takes place Locking action Bolt does not could not be reach end position completed Lock bolt is blocked Lock is Low battery engaged but warning level 1 batteries in lock are virtually spent Based on Change the atte of _ CL SS CD batteries soon ocking Lock cannot Low battery be engaged warning level 2 any more The ba
8. tteries in the loc Based on are spent example of Change the unlocking GSD batteries Page 7 BDA M300 SV GB Rev 02 23 06 2014 LEHMANN Vertriebsgesellschaft mbH amp Co KG Postfach 2620 D 32429 Minden Page 8 BDA M300 SV GB Rev 02 23 06 2014