Home

User`s Manual

image

Contents

1. 1 Dimensions of X when mounted the GOT 8 15 69 s 30 5 meg 180 12 1 O71 Unit mm inch 19 0 75 Description Connector for RGB Connector for connecting a 9 core output combined cable 2 Interface connector Connector connected to the GOT Connector for connecting an extension 3 Extension connector unit Screw for fixing the extension interface 4 Board fixing screw relay board 5 Mounting screw Screw for fixing the RGB output unit 6 Rating plate 3 2 Extension Interface Relay Board O O 64 2 52 24 0 94 b 27 5 1 08 Unit mm inch CAUTION Always secure the cables connected to the unit e g run them in conduits or clamp them Not doing so can cause unit or cable damage due to dangling moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault Do not hold the cable part when unplugging any cable connected to the unit Doing so can cause unit or cable damage or a malfunction due to a cable contact fault Always make sure to touch the grounded metal to discharge the electricity charged in the body etc before touching the unit Failure to do so may cause a failure or malfunctions of the unit DISPOSAL PRECAUTIONS CAUTION Dispose
2. Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 I 20041 Agrate Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 South Africa Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 928 2000 Hong Kong Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road North Point Hong Kong Tel 852 2887 8870 China Mitsubishi Electric Automation Shanghai Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Taiwan Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Korea Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Singapore Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2460 Thailand Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 Indonesia P T Autotekni
3. of this product as industrial waste TRANSPORTATION PRECAUTIONS CAUTION Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the GT16 User s Manual as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation Manuals The following shows manuals relevant to this product Detailed Manual Manual Number Manual name Model code GT16 User s Manual SH 080778ENG Sold separately 1D7M23 GOT1000 Series Connection Manual 1 3 to 3 3 SH 080532ENG Sold separately 1D7M88 GT Designer2 Version2 Screen Design Manual For GOT1000 Series 1 3 to 3 3 Sold separately SH 080530ENG 1D7M25 Relevant Manuals For relevant manuals refer to the PDF manuals stored in the GT Designer2 CD ROM 2008 MITSUBISHI ELECTRIC CORPORATION 4 INSTALLATION PROCEDURE 1 Turn off the GOT 2 Remove two extension unit covers of the GOT 3 Connect the extension interface relay board to the extend I F 2 on the GOT Remove the connector cover from the board 4 Fit the RGB output unit in the GOT case Remove the connector cover 5 Tighten four mounting screws with a torque of 0 36 to 0 48 Nem to fix the unit 6 Tighten two boar
4. MITSUBISHI GT16 RGB Output Unit User s Manual GT16M ROUT Thank you for purchasing the GOT1000 Series Prior to use please read both this manual and detailed manual thoroughly to fully understand the product MODEL GT16M ROUT U MODEL CODE 1D7M86 IB NA 0800430 A 0808 MEE GRAPHIC OPERATION TERMINAL GOTioo9o0 SAFETY PRECAUTIONS Always read these precautions before using this equipment Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this prod uct In this manual the safety precautions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause O DANGER hazardous conditions resulting in death or severe injury l I l I l I Indicates that incorrect handling may cause l A CAUTION hazardous conditions resulting in medium or l slight personal injury or physical damage j Note that the A CAUTION level may lead to a serious accident according to the circumstances Always follow the precautions of both levels because they are impor tant to personal safety Please save this manual to make it accessible when required and always forward it to the end user DESIGN PRECAUTIONS CAUTION Do not bunch the control wires or communicatio
5. d fixing screws with a torque of 0 36 to 0 48 Nem to fix the board 7 For mounting any extension unit on the RGB output unit remove the connector cover and the stickers For mounting no extension unit on the RGB output unit cover over four mounting screws with the accessory stickers to avoid static electricity Keep the connector cover fixed Keep all the stickers fixed Connector cover Accessory sticker Accessory sticker Point Remove the screws that fixes the extension interface relay board before removing the unit Above 6 Packing List After unpacking the box check that the following products are included Model Product Quantity RGB output unit 1 GT16M ROUT Mounting screw set 4 screws 4 1 stickers Extension interface relay board 1 1 OVERVIEW This User s Manual describes the GT16M ROUT RGB output unit referred to as the RGB output unit hereinafter When mounting RGB output unit with GT16 unit can external display screens on GOT M the RGB output GOT GT16M ROUT External display To use the RGB output unit set the communication settings For the settings and system configurations refer to GOT1000 Series Connection Manual For RGB output functions refer to GT Designer2 VersionO Screen Design Manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause
6. g chart Refer to 2 2 Refer to 2 3 Connector for external i D Sub15 pin female connection Internal current 3 3VDC 0 13A consumption 5 0VDC O11A Weight 0 17 kg 0 34 Ib 2 2 GT1695M X Timing Chart Horizontal synchronizing timing Vertical synchronizing timing Video signal 15 754 us Video signal RGB RGB 15 880ms analog saad gt 0 7Vp p O7Vep HSYNC VSYNC Vertical sync width 2 462 us fef0 369 us 0 12am Tot 0 800msHe 0 062ms 2 082 Hs Horizontal sync Vertical sync_ 20 677 us Horizontal sync width Vertical synchronizing timing Horizontal synchronizing timing 2 3 GT1685M S Timing Chart Horizontal synchronizing timing Vertical synchronizing timing Video signal Vid I R 20 000 us a 16 840m5 le k analog analog 0 7Vp p PRR VSYNC HSYNC Vertical sync width Horizontal gt 1 0 607ms gt 0 026ms sync width 0 106ms Vertical sync 2 200 us j4 gt 1 000 us 16 579ms 3 200 us Horizontal syne 26 400 us Vertical synchronizing timing Horizontal synchronizing timing 3 PART NAMES AND EXTERNAL DIMENSIONS 3 1 RGB Output Unit 3 5 133 5 24 3 GOT main unit 105 4 13 Ti x
7. n cables with the main circuit or power wires or lay them close to each other As a guide separate the lines by a distance of at least 100 mm 3 94 inch Otherwise malfunctions may occur due to noise INSTALLATION PRECAUTIONS lt gt DANGER Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to from the GOT Not doing so can cause a unit failure or malfunction Before connecting the Bus connection cable to this unit always shut off GOT power and PLC CPU power externally in all phases Not doing so can cause a malfunction CAUTION Use this unit in the environment given in the general specifications of the GT16 User s Manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration Do not drop the unit or subject it to string shock A unit damage may result When installing this unit to the GOT fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range Undertightening can cause a drop failure or malfunction Overtightening can cause a drop failure or malfunction due to screw or unit damage WIRING PRECAUTIONS lt gt DANGER Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions CAUTION Exercise care to avoid foreig
8. n matter such as chips and wire offcuts entering the unit Not doing so can cause a fire failure or malfunction Make sure to securely connect the cable to the connector of unit Incorrect connection may cause malfunctions STARTUP AND MAINTENANCE PRECAUTIONS gt DANGER Before starting cleaning always shut off GOT power externally in all phases Not doing so can cause a unit failure or malfunction Undertightening can cause the GOT to drop short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit Do not disassemble or modify any unit This will cause failure malfunction injuries or fire Do not touch the conductive areas and electronic parts of this unit directly Doing so can cause a unit malfunction or failure 2 SPECIFICATIONS The following shows the performance specifications of the the RGB output unit The general specifications of the RGB output unit are the same as those of the GOT For the general specifications of the GOT refer to GT16 User s Manual 2 1 RGB output unit Specifications GT1695M X GT1685M S RGB output format Analog RGB XGA SVGA Display size dot 1024 x 768 800x 600 Number of RGB output 1 channel channels Dot clock 65 000 MHz 40 000 MHz Horizontal scanning fi 48 400 kHz requency 37 900 kHz Vertical scanning fi 60 004 Hz 60 317 Hz requency Timin
9. ndo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 India Messung Systems Pvt Ltd Electronic Sadan NO III Unit No15 M I D C Bhosari Pune 411026 India Tel 91 20 2712 3130 Australia Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 xMITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice Printed in Japan
10. of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties Z For safe use This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel USA Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Germany Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 U K Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100

Download Pdf Manuals

image

Related Search

Related Contents

User Manual EDK 350 (868 MHz) EDK 350U (902 MHz)  KIT III Installation Guide Guía de instalación del KIT III KIT  Manuel d`utilisation Industry Mall  Troy-Bilt 42051 Snow Blower User Manual  IFU Delta-Domino_LR-HR-STEAM-D NEW.fm  Instrucciones para el acceso de los padres a  Gfan version 0.5: A User's Manual    BenQ PB2120 Multimedia Projector  2.0 USB - Verbatim  