HUNTER-PRO RSA Intruder Alarm System LCD
Contents
1. HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads 4 1 2 6 Programming User Partitions E Set user s arion C This feature links a user to a partition s When creating subsystems there is also a keypad linked to each split done by the technician therefore the user can only arm disarm and view the linked partition using the designated keypad To enable a user to control his partitions from any keypad the option K on the authorization bar should be set to With standard system installation i e no partitions all users are assigned by default to all partitions 4 1 3 Programming Door Code This code controls the system s relay for opening and closing electric gates activating video cameras and more The relay can be controlled manually directly pressed on keypad and remotely via telephone see section 3 4 Remote Controlling via Telephone Each entering of a Relay Code changes the relay s status ON to OFF and vise versa OR the technician can program to activate it according to a preset time When the relay is ON the letter R appears on the display left to the time The Code is between 4 to 6 digits EF Master Code Enabled User Code long press User Code 2 The following screen will appear Ce Back cer nrn Enter new code 4 to 6 digits Eur to save new relay code press lt S to exit HUNTER PRO RSA Intruder Alarm System Us
2. GE ime in which the system will be armed HH MM NOTE Sy To cancel Auto Arming the Automatic Arming programming needs to be repeated and the time to be set as 00 00 Press to save programming and move to the next screen 4 3 2 Programming Auto Arming after Silent Time Terminated PROG S7 Master Code Enabled User Code long press User Code So ENTR eo eam In the following screen enter the Silent Time period in minutes after the system commences auto arming call 250 minutes max ad ENTR PER mark with the partitions designated for RESE automatic arming silent time use key in order to change mark from HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads SERVICE NN to and vise versa and partitions 4 4 Private Dialer Telephone Numbers HUNTER PRO RSA system has four private dialer telephone numbers The dialer will dial each phone number in two sets i e total of 8 attempts and trigger an alarm warning sound when the call is picked After the warning sound is over the system awaits for remote controlled commands that can be transmitted via the telephone used by the system The system Shall hang up after a minute of not receiving any command Remote Control via Touch tone Phone on page 17 NOTE S In case a Voice Unit is connected to the system once the call is picked up there is a recorded message and not a warning sound The dialer aborts
3. 10102 10103 etc will display an error message 4 1 1 Programming Master Code The default Master Code is 5555 The Master Code can ONLY be changed with the master code The Master Code is used for accessing memory and programming different function as described further It is also possible to arm and disarm the system with the Master Code A 4 A IMPORTANT Pay attention that the code need to be between 4 and 6 digits HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads CODE ENTR rage oe 25 Eveline TN For better protection change the default code after installation 4 1 2 Programming Users The User Codes are mainly for arming and disarming but depending on the user s authorization level the user can also go into the User Menu and perform various tasks as viewing memory changing other users settings program telephone numbers etc HUNTER PRO RSA holds up to 24 different User Codes 4 to 6 digits each See Entering User Menu on page 11 for a description on how to access the User Menu with User Code S gt NOTE A name can be programmed for each user a time frame in which he will be able to disarm the system allocated to one partition or more and specific authorizations CODE GE Master Code Enabled User Code long press User Code S The following screen will appear Master Code SERVICE Enter user number 1 24 NOTE
4. 3 2 Arming DisarMing with Key ar 16 333 Disarming the System 16 3 4 Remote Control via Touch tone Phone 17 CH 4 PROGRAMMING amp OPERATIONN 20 4 1 Programming Codes arrrrnrnrrnrnrnnrnennnnrnnnnennnnrnensvnensnnnnensnnensnnene 20 42 Programming Time and Date a r 26 43 Automatic Armind a arrrrsrnrrsssrssrsssssssssaa 27 4 4 Private Dialer Telephone Numbers 29 15 II EEE NE 30 DN 31 4 7 Smoke and Fire Detectors Alarm r 31 4 8 System Tests EEE EE EEE 31 4 9 Canceling Keypad BUzzer 32 4 10 Bypassing ZOon S uuu usa raian wakquaqakus 32 TAL VENN NG 33 4 12 System Display 34 CH 5 TROUBLESHOOTING uu u uu uuu usus 36 51 ZONES NGIWIGS2u NN 38 HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads CH 1 INTRODUCTION Congratulations on your purchase of the HUNTER PRO RSA Intruder Alarm System Much care has been taken in developing the HUNTER PRO RSA Intruder alarm system which will provide you with unprecedented peace of mind The HUNTER PR
5. 1 31 Expander siren and 12 Siren 22 Output no 2 no 1 dialer 13 Relay output 01 Arm 14 SMOKE i 32 Expander 02 Disarm detector no 2 04 Home1 15 ON OFF Ourpul 07 Home 2 output 33 Expander no 3 08 Listen in 16 ALARM output 28 Output no 8 output During communication time HSS KE ang gay the following display will appear If the system receives no command within a minute it will disconnect from the line and return to normal operation Examples Disarm the system Dial and wait for confirmation tone and wait for confirmation tone E on telephone keys E Activate output No 5 on output card OUT 1000 Dial and wait for confirmation tone and wait for confirmation tone on telephone keys e E HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads CH 4 PROGRAMMING amp OPERATION 4 1 Programming Codes A code is a combination of numbers that allows programming arming disarming the system and more During the programming process the keypad s display will show the name of the code you want to program At any stage of the programming it is possible to return to the main menu by IMPORTANT Pay attention that HUNTER PRO RSA has a code control feature that does not allow entering identical codes For example if one of the user or master codes is programmed as 1010 any attempt to program a new code as 1010 or starting with 1010 e g 10101
6. 34 how to change displays 2 1 1 PIMA User Friendly Display All events and zones displayed in a single screen using signs and abbreviations r se status 22 es o Zone Status and Events Upper Line Display when there are up to 16 zones Time date and system status if system has 16 zones or less see upper line display description in section 2 1 2 Lower Line Display when there are up to 16 zones Or both lines display when there are more than 16 zones The following signs appear next to the zone number partitions that encircle the LCD screen Closed zone HHH Opened zone Bypassed zone Alarm zone zone triggering alarm Chime zone HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads x x Shortcut zone zone is shortcut a Failed zone disconnected Tamper event in a wireless detector z Low battery in wireless detector L Supervision signal Wireless detector did nor report test to system Zone is in Soak test 2 1 2 Scrolling The zone and event screens automatically interchange and display their status in a chronological order ET aerate 23 24 25 2 29 30 31 32 1 2 3 4 Upper Line Display Time and date System status displayed between time and date i System communicating or testing PSTN line Siren ON Relay ON System reporting to Monitoring Station via radio transmitter Lower Line Display Event alerts and faults Alarmed zones ii HUN
7. the dialing attempts in the following cases The system s status changes from ON to OFF A Stop Dialer command was received via telephone The first Private Dialer User that gives an abort command causes the other Private Dialer Users in the phone list will not receive the system s report All Private Dialer Telephone Numbers have been dialed twice 4 4 1 Programming Telephones It is possible to combine the process of entering deleting changing programmed telephone numbers once in the Telephone Menu HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads er Master Code Enabled User Code long press User Code E Enter Telephone number no 1 SENTRE Enter telephone number no 2 ar Ente ar Enter Telephone number noe ENTRI E Enter Telephone number no 4 co Ena a en to exit 4 4 2 Deleting a Programmed Telephone Number To delete a programmed telephone number press the key instead of the telephone number Programming the Chime feature enables to control opening closing doors and windows by activating the keypad s buzzer for two seconds each time a door window is opened This feature is especially useful when there are small children in the house or in shops NOTE The Chime feature is only enables when system is disarmed 4 5 1 Programming Chime Zone GE Master Code Enabled User Code long press User Code GE or to release On the display the letter
8. An asterisk placed to the right of the user s name means that the user has valid code programming Following are the different options with user programming HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads 4 1 2 1 Changing adding new User Code Use Ja and number E gt ENTR I User Code 4 to 6 digits SET to reach i user press user s 4 1 2 2 Deleting User 4 1 2 3 Entering User Name Use F lt and to reach designated user press user s SE jo FE ex ver ENTER HES END E Enter name er Ena How to Select and Enter Characters Each numeric code entry key has characters associated with it the same as with standard cell phone letters The number of key depressions you make determines which character is selected e g the numeric key represents MNO6 To select M press the key once to select O press the key three times See bellow for all keys and their associated characters Pressing the Next key moves the cursor forward one character Pressing the key moves the cursor backwards one character HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads Pressing the key saves the data RESET Pressing the 2 key clears the display User Name includes up to 8 characters letters or digits Each arming disarming will enter the memory along with the user name date and time see section Memory Display on p
9. It is possible to arm the system with open zones but these zones should be bypassed for the system to be armed see Arming with Open Zones on page 13 3 1 Arming amp Disarming via Keypad 3 1 1 System Messages During Arming 3 1 1 1 Arming with Closed Zones normal arming Before arming the system make sure all zones except exit delayed zones usually zones on exit route are closed make sure that in the keypad display above below all the LCD zones numbers there is not a sign blinking or an opened zone indication The system can be activated using one of the following codes User Code Short Code and Master Code HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads After entering one of these codes the green control LED shall begins to blink a beep will be heard from the keypad and the display will show the exit delay message At the end of the exit delay the green control LED shall stop to blink and stay on me l will a ane the display will show the following message appo biome 3 1 1 2 Arming with Open Zone s When activating the system with one or more opened zones that are not on the exit route i e exit delayed zones the keypad will produce a fast beep and the ea will show Scrolling line Open Zones amp Events To bypass open zones er 23 open zones are bypassed amp system armed To cancel arming system returns to normal operation mode 3 1 2 Arming with Mast
10. Menu can be fully accessed by the system administrator owner when using the Master Code Other users can also access the User Menu but are limited to the number of available functions according to their authorization level programmed by the system administrator owner To learn more about authorization levels and how to change them see Programming Codes on page 20 2 3 1 Entering User Menu with Master Code To access the User Menu E Master Code ee E Function key see page 10 2 3 2 Entering User Menu with User Code If user is enabled by technician to enter the User Manu E Haane du S Function key see page 10 If user is not enabled by technician to enter the User Menu i e User Code arms disarms the system the menu can still be accessed as follows When user selects a function i e the corresponding key is pressed that he or she does not authorized to the system displays the following see HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads CH 3 ARMING amp DISARMING THE SYSTEM The system can be armed and disarmed using one of four methods Keypad Remote control or keyfob Automatically arming only Remotely via touchtone telephone COMAX software Internet and GSM As a rule the system should be armed ONLY when all zones but those on the exit route are closed and there are no faults e g battery mains etc and or events e g fire panic etc
11. O RSA user friendly operation and advanced features will professionally protect your home or business HUNTER PRO RSA Intruder Alarm System contains numerous features that allow it to befit the customer s individual needs and yet remain easy to program and use both by the customer and the technician Therefore it is important to read this manual from cover to cover in order to familiarize yourself with the system and take full advantage of its features To assure optimal safety and security you should test the HUNTER PRO RSA Intruder Alarm System once a week For any further questions please do not hesitate to contact your local PIMA distributor or PIMA directly at PIMA Electronic Systems Ltd Tel 972 3 558 7722 Fax 972 3 550 0442 Email support pima alarms com Up to date literature is available to download from our website www pima alarms com HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads 1 1 Main Features HUNTER PRO RSA 9 zones in control panel Zone doubling for control panel on board zones total 16 zones Expanded up to 32 zones with wireless add on local and remote bus expanders Supports a wide range of partition options Up to 16 partitions each with its own Account ID and Users Up to 8 subsystems each with different keypads IDs etc Full supervision data of wireless detectors Supervision low battery tamper Comprehensive Zone Tests for flawless installation
12. PA FOR BETTER PROTECTION HUNTER PRO RSA Intruder Alarm System LCD Keypads User Guide PIMA Electronic Systems Ltd 5 Hatzoref Street Holon 58856 Israel 972 3 5587722 Lan a 972 3 5500442 z Support pima alarms com ay http www pima alarms com HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads PIMA Electronic Systems Ltd does not represent that its Product may not be compromised and or circumvented or that the Product will prevent any death personal and or bodily injury and or damage to property resulting from burglary robbery fire or otherwise or that the Product will in all cases provide adequate warning or protection The User understands that a properly installed and maintained equipment may only reduce the risk of events such as burglary robbery and fire without warning but it is not insurance or a guarantee that such will not occur or that there will be no death personal damage and or damage to property as a result PIMA Electronic Systems Ltd shall have no liability for any death personal and or bodily injury and or damage to property or other loss whether direct indirect incidental consequential or otherwise based on a claim that the Product failed to function Warning The user should follow the installation and operation instructions and among other things test the Product and the whole system at least once a week For various reasons including but not limi
13. TER PRO RSA Intruder Alarm System User Manual for LCD keypads Operating and programming the system commences by first entering the Master Code and then pressing any further required keys However a number of keys enable certain actions by a single long press without the Master Code After entering Master User Secondary Function Code short press long press my System Arming Disarming Fast arming the system 1 if enabled by technician Display arming alarm and fault histories nm Arming the system to mode Home 1 Fast arming the system to Home partial arming 1 mode if enabled by technician gt Display menu see section Zone Status 3 Display a Programming telephone numbers pa nom2 Arming the system to mode Home 2 Fast arming the system to Home partial arming 2 mode if enabled by technician Programming zones for Chime feature Enabling Disabling the Chime feature Programming automatic arming and silent time per partition 9 Programming key Smoke detector reset Programming key Clearing alarmed zone indication Programming key Display service Provider information Programming key Test siren battery AC and tel line HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads Programming key Display system s name and version 2 3 Entering User Menu In order to program and change data in the user level you must first enter the User Menu User
14. Walk Test Soak Test etc Two options for viewing system status Detailed Scrolling events zones and system s status PIMA Style Status of all 32 zones is displayed simultaneously Four Subscriber dialing numbers with optional voice message Four Monitoring Stations phone numbers PIMA unique Integrated Digital Communicator telephone long range radio Supports split and double reporting to two monitoring stations with different account IDs LCD keypad with multilingual Menu Driven screens for easy programming and operation as well as budget LED keypads Many alternatives for easy programming Keypad Fast Programmer Local Remote download software Up to 24 users with various authorization levels Various accessories mic voice unit etc Memory Log up to 410 events 128 non volatile Automatic Arming at a preset time and or after a preset silence time System remote control via any touchtone telephone Sirens monitored and reported for wires cut to CMS Various test options for zones and devices f f f x x x HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads 1 2 Signs and Abbreviations Key P Regular key press Long key press until confirmation beep is heard Press this key at any programming stage in order to return to root screen Default Master Code 5555 Enabled User Code A code enabled by Master Code to enter User Menus LCD Zone Numbers Re
15. age 33 The order of the ABC letters is identical to that in a cellular phone 1 ABC2 DEF3 Cancel ON OFF MEMO BYPASS 1 2 2 e GHI4 JKL5 MNO6 Next char HOME 1 ZONE PHONE SERVICE 4 Us 6 eg PQRS7 TUV8 WXYZ9 Prev char J 2 2 ey Space 0 Save CHIME RESET 2 a em The following example illustrates writing the word 7PIR Character Key Pressed Follow Key KE 7 O 7 EN O 4 Zz mn wa G c lp HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads 4 1 2 4 Modifying User Access SERVICE NEXT To scroll on Access Bar use NEXT and Marking a under a parameter s letter authorizes the user to program this parameter Marking a denies this possibility wn In order to change the mark from to and vise versa press To save data press User Access Bar parameter letters U User can program User Codes T User can program phone numbers C User can program time and date M User can view the Memory Log B User can bypass zones K User can operate partition via any keypad when using partitions A User can program auto arming parameter 4 1 2 5 Programming Users Disarming Time Period SERVICE Eur ope y4 EF Enter time EE This feature sets the time frame start and end time in which the user can disarm the system By default the user time is not limited i e start 00 00 end 23 59
16. er Code Ep En S MA NN NOTE The The system s default Master Code is 5555 S default Master Code is 5555 3 1 3 Arming with User Code and or Short Code Pressing the code shall arm the system immediately Se Short Code E HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads 3 1 4 Arming the System to HOME Mode Arming to HOME 1 pLa GE Short Code or User Code Arming to HOME 2 PL E Short Code or User Code After long pressing the HOME key i e short user master code the following message is displayed x according to the pressed key 3 1 5 Fast Arming To quickly arm the system if enabled by technician ON OFF Full Arming p k Arming Home PAI Arming HOME 2 p 7 S gt NOTE Exit delays in HOME 1 and HOME 2 can be disabled by technician 3 1 6 Arming via the User Menu If user is enabled ey technician to enter the User Manu If user is not enabled by technician to enter the User Menu it can still be accessed as follows PLO p ON OFF HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads 3 1 7 Arming with Keyfob Indication LED lit when keyfob buttons pressed VISONIC s keyfob is designed for PIMA s IO W wireless receiver The keyfob remote Relay control includes 4 buttons Arming that allow 5 actions arming disarming HOME1 relay Panic pressing control and panic Up to 24 simultaneously HOME1 ue l A ar
17. er Manual for LCD keypads 4 1 4 Programming Short Code This two digit code can only arm the system E Master Code Enabled User Code long press User Code 9 E X2 EER hisi En er Ent Enter new code 2 digits GE to save Press DENE 4 1 5 Programming Duress Code This code is useful when the system is connected to a security station The Duress code will disarm the system if armed and trigger the Silent Alarm sending a duress signal to the security station without activating the sirens Note the code is between 4 to 6 digits GE Master Code Enabled User Code long press User Code 23 The following screen will appear gt Bact x3 digits co Eta to save Press to exit 4 2 Programming Time and Date Time and date are constantly displayed on screen used for the User Code s time frames and are included in the system s memory log Make sure the time and date remain accurate because of the memory log and automatic arming HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads CLOCK E Master Code Enabled User Code long press User Code es The following screen will appear Enter time in 24 00 HH MM format and date in day month year format The system will not accept meaningless data such as 25 25 time In such a case an error message will appear To correct press the key and enter time again 4 3 Automatic Arming The system can be automatically armed with one
18. er Master Code note NOT to enter the code before the end of the confirmation tone 4 Wait a few seconds until the alarm system confirms its status using one of the two following tones Continuous tone System disarmed Beep System armed HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads S gt NOTES The system will not identify commands from the telephone while sounding the confirmation tone It is important to wait until to confirmation tone is over before pressing the telephone keys that control the system The alarm system confirms the command was received by two short beeps There are two modes for controlling the system as set by the technician 3 4 1 MODE A One touch control 5 Execute command by pressing a key on the phone The following table includes system s commands by phone keys Phone key Function Arm the system Disarm the system Arm the system in Home 1 mode Switch on the Relay Switch off the Relay Arm the system in Home 2 mode Listen in only available with a MIC 200 Disables siren and dialer in case of an alarm OOnN DD UI BN 3 4 2 MODE B Enhanced control IMPORTANT To activate each of the outputs amp allocated phone keys To deactivate each of the outputs EN amp allocated phone keys HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads General Controlpanel Output card 00 Disable 11 Siren 21 Output no
19. ess zone the letter W will appear along with the zone name HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads CH 5 TROUBLESHOOTING If more then one failure is detected the display will scroll the failure list one after the other If more than one keypad is connected to the HUNTER PRO and you are Progr anne me zo momy one e Wen the display on all other keypad will display Lr This will also be displayed Are someone is in Re of the HUNTER PRO RSA via telephone The following table describes the possible Alarm System Faults Displayed Fault What can I do Wait approximately 24 hours for the indication to disappear If the fault indication persists longer then one day the back up battery should be replaced Usually appears during a power failure If other electrical appliances in the house are operating check the switch or fuse to which the alarm system is connected If the cause of the fault is unclear call the technician Appears following a prolonged power failure during which the backup battery was completely discharged Set time and date see section 4 2 Perform system self test see section4 8 Verify during the test that other instruments connected to the Alarm System s telephone line i e telephone sets facsimiles etc are not active If the fault persists call the technician Tamper switch 1 is open Call the technician Tamper switch 2 is open Call the tech
20. ferring to the frame of zones engraved above and below the LCD display window indicating the zones numbers HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads CH 2 KEYPADS HUNTER PRO RSA works with PIMA s LCD keypads RXN 400 and RXN 410 especially designed for maximum simplicity durability and decorative design The keypad is used for arming disarming and programming the system as well as displaying time and date system status information events and defaults memory log and more Both keypad models are identical except for the size of the display screen RXN 410 Large screen 23 x 97 mm RXN 400 Small screen 15 x 60 mm Up to eight keypads can be connected to the system System display System display Date amp Time Be nee A Zones Status NPS TL TT III ee ee Sat lu p ee iS l Le TTF Num amp Function ARM LED green keys Fault LED Navigation amp red Programming keys Drawing 1 PIMA LCD RXN 410 keypad with PIMA Display HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads 2 1 Display Screen The display screen has two lines with 16 characters each The upper line displays the time and the date The lower line displays data regarding the system such as events faults and zone status The user can choose between two display types scrolling fast zone display and PIMA display See section 4 12 on page
21. for LCD keypads Partition Zone Name No P N 4410211 Rev A Sep 2005 lt
22. ming keyfobs can be added to fap 3 seconds HUNTER PRO RSA Intruder Alarm System 3 1 7 1 Allocating Keyfob to User FLEET ne first user allocated to the system will appear for example scroll with te and keys until designated user or enter the user s number 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 GE Toul dan a 12345678910111213 141516 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 12345678910111213 141516 er press one of the keyfob s buttons and wait 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 confirmation 12345678910111213 14 15 16 to exit To allocate a different keyfob to a different user repeat this operation with the new designated user and keyfob After allocating keyfob to user the letter K will appear on the user code screen Sy NOTE Up to 24 user code can be programmed and in addition 24 keyfobs HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads 3 1 7 2 Canceling Keyfob for User Z Master Code allocated to the system will appear for example x and acd I keys until designated user or enter the user s number or the 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 designated code ENTR Back 123456789410 111213 1415 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 1234567891011 12 13 14 15 16 wait for confirmation 123456789101112 13 14 15 16 to exi
23. nician HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads Appears before the back up battery is completely discharged usually after a prolonged power failure Follow instruction for low battery failure One of the protected zones is faulty Call the technician Software failure Call the technician System failure Call the technician Failure to communicate with Monitoring Station Call the technician Detector power supply Call the technician No communication between the keypad and the HUNTER PRO motherboard Call the technician GSM unit not connected operating properly Call the technician Bad reception or blocking of GSM channel Call the technician No SIM card detected Call the technician Wireless receiver unit not connected working properly Call the technician Check that wireless receiver box is properly closed If problem remains call technician The wireless receiver is jammed Call the technician No connection between panel and external Bell Call the technician Fault in communication between GSM and MS Try to initiate another dial If doesn t work call the technician No connection between panel and internal Bell Call the technician d HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads 5 1 Zones Names Partition Zone Name No r 2 3l 4 o s 6 7 8 io a 32 gt 3 a as i6 HUNTER PRO RSA Intruder Alarm System User Manual
24. of the following three options 1 At a preset time 2 After silent time period 3 Silent time can be programmed per partition by technician At the preset time or after silent time period the system will commence auto arming unless it was armed before that time This feature is valid for all weekdays The system can detect movement in the protected area via its connected detectors and sensors therefore it can identify no movement hence there is no one in the protected area The silence no movement timer will start counting down ONLY if no immediate zone are open and after the last zone to close is the exit delayed zone i e the exit door Any immediate zone opening will terminate the countdown When the system starts auto arming the display will show Automatic Arming and a 45 seconds warning countdown will start indicating the arming countdown is to follow Note that during the warning countdown the keypad will beep During the warning countdown any disarming code can cancel the auto arming process HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads After the warning countdown is over the system will begin regular arming process including exit delay and beeps from the keypad 4 3 1 Programming Auto Arming at Preset time PROG er Master Code Enabled User Code long press User Code eLo The following screen will appear Press and move to the next screen UA
25. shall appear above below the zone programmed to trigger the chime and the screen will move to the next zone E Enter zone number aaki to confirm HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads 4 5 2 Temporary Cancellation of Chime Temporary cancellation of chime is valid for all zones PEJ Press and hold the key to enable disable the chime feature according to the state in which the system is in the display will show one of the following messages Chime ON Chime OFF 4 6 Panic To activate panic press and hold simultaneously the for two seconds You can customize your system s response to a panic event for example calling the Monitoring Station or your private telephone number activate a relay video camera activate siren etc Consult your installer about programming the appropriate Panic Response for your needs 4 7 Smoke and Fire Detectors Alarm In case an alarm is triggered due to smoke fire detectors press and hold the _ key until a confirmation sound in order to reset and release the detector 4 8 System Tests This feature tests that the back up battery siren and telephone line are in order er Master Code Enabled User Code long press User Code Follow the test process displayed on the screen in case fault messages appear HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads 4 9 Canceling Keypad Buz
26. t To cancel a different keyfob to a different user repeat this operation with the new designated user and keyfob After canceling keyfob for user the letter K will disappear from the user code screen 3 2 Arming Disarming with Key HUNTER PRO RSA can be armed disarmed with a key Turn to the technician in order to install this feature NOTE Sy It is possible for the technician to program the system to produce a short beep when the system is armed disarmed with the key 3 3 Disarming the System 3 3 1 Disarming the System with User Code ON OFF GE Master Code Enabled User Code long press User Code En HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads If the system does not turn to Disarm state make sure that the time is included in the preset time frame that enables disarming the system see section 4 1 2 5 in Programming User Codes 3 3 2 Disarming the System with Master Code ON OFF fy 3 4 Remote Control via Touch tone Phone The alarm system can be remote controlled via any touch tone telephone including cellular phone The system can be controlled from the moment there is communication between the system and the telephone whether the system called the telephone or when initiated by the user as following described 1 Dial the telephone number the system is connected to 2 Wait for the system s confirmation tone a long tone followed with two beeps 3 Ent
27. t Date amp Time A Zone type Event Zone Number Note that at a time of an alarm in addition to the screen above another screen automatically appears with the zone s name HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads Example 2 Zone name Example 3 HUNTER PRO RSA has two system status displays and seven types of zone Status display The two system status displays are Fast Display All the zones and their status appear in a single screen Scrolling Display A detailed description of the zones and their status each zone in a different screen and automatically appearing one after the other In order to choose display types 4 12 1 Fast Zone Display E Master Code Enabled User Code long press User Code E ENTR sjeer display changes to PIMA Fast Display HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads 4 12 2 Scrolling Zone Display E Master Code Enabled User Code long press User Code E ZONE SERVICE cc NEXT Ger display changes to Scrolling Display 4 12 3 Zone Status Display E Master Code Enabled User Code long press User Code ZONE SERVICE fen SERVICE Spey SERVICE SERVICE Sked SERVICE SERVICE Sked SERVICE Sked IMPORTANT Pressing in All Zones Bypassed Zones Soak Zones Chime Zones screens gives a detailed description of the zones in this category For wirel
28. ted to changes in environment conditions electric or electronic disruptions and tampering the Product may not perform as expected The user is advised to take all necessary precautions for his her safety and the protection of his her property This document may not be duplicated circulated altered modified translated reduced to any form or otherwise changed unless PIMA s prior written consent is granted All efforts have been made to ensure that the content of this manual is accurate Pima retains the right to modify this manual or any part thereof from time to time without serving any prior notice of such modification Please read this manual in its entirety before attempting to program or operate your system Should you misunderstand any part of this manual please contact the supplier or installer of this system Copyright 2005 by PIMA Electronic Systems Ltd All rights reserved You can contact us at PIMA Electronic Systems Ltd 5 Hatzoref Street Holon 58856 Israel http www pima alarms com SAFETY INSTRUCTIONS Your HUNTER PRO RSA alarm system has been registered in accordance with EN60950 and its rules EN 60950 requires us to advise you the following information 1 In this alarm system exists hazards of fire and electric shock To reduce the risk of fire or electric shock do not expose this alarm system to rain or moisture Pay attention Telephone cords could be a good conductor for lightings energy Do not open
29. the door of the alarm system Dangerous high voltages are present inside of the enclosure Refer servicing to qualified personnel only This alarm system should be used with AC 230V50Hz protected by anti electric shock breaker To prevent electric shocks and fire hazards do NOT use any other power source Do not spill liquid of any kind onto the unit If liquid is accidentally spilled onto the unit immediately consult a qualified service Install this product in a protected location where no one can trip over any line or power cord Protect cords from damage or abrasion Disconnect all sources of power supply before proceeding with the installation Pay attention do not install low voltage wires near by AC power wires they should be separated Connect the AC transformer output to the terminal block on the control panel as marked Connect the AC line cord to line power terminals as marked GND N L HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads TABLE OF CONTENTS CHid INTRODUCTION arve 4 1 1 Main Features HUNTER PRO RSA J 1 2 Signs and Abbreviations Key 6 CHi2e KEV PADS uuu uuu uuu ua 7322 7 ZA Dip SN 8 22 K Oy EE EE EE 10 2 3 Entering User MEN 11 CH 3 ARMING amp DISARMING THE SYSTEM 12 3 1 Arming amp Disarming via Keypad 12
30. zer The keypad produces a variety of sounds at times of pressing a key confirming a long press during countdown disarming the system and so on Simultaneously pressing the J keys activates cancels this feature NOTE Sy When the buzzer is cancelled no sounds will be produced from this specific keypad 4 10 Bypassing Zones This feature is used for temporary bypassing of zone s for example in case of a fault EG Master Code Enabled User Code long press User Code er gt re to confirm or In PIMA Display the letter B will appear above below the bypassed zone s and display will continue to the next screen The technician can limit the time window for a bypassed zone before the system is armed HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads 4 11 Memory Log The system memorizes up to past 410 events and operations in a chronological order IMPORTANT The last 128 events are non volatile 4 11 1 Accessing Memory Log Manually GE Master Code Enabled User Code long press User Code GE 2 scroll events using NEXT and Press EZ to jump 10 next events in one key press Press to jump 10 events back in one key press 4 11 2 Memory Log Display Includes arming and disarming along with user name and code and any zones bypassed prior to arming The list of the bypassed zones is presented before those of the arming Example 1 Event Number Even