CONTROLS ZONE STATION II

image

Contents

1. dim n X 6 METRE BEIGE CABLE IL n X 24V GREY MOTOR DENOTES NUMBER OF ow ZONES DUE I 0 ZA E 32 O A d xt re 2 a 4 J 55 O A ON E 4 7 136 O A Ten Bo Pe v 125 96 REVISION 28 08 03 I ZSII 1 ZONE STATION Il CONTROLS ZONE STATION Il INSTALLATION INSTRUCTIONS AdvantageAir 1 Ensure A C system is running correctly and switched off Mount the Control Panel s at the desired locations Connect the system as per DIAGRAM 1 Do not power up the system at this stage 4 Connect the zone motors using the Beige cables provided starting from Zone 1 If Programmed Con stant Zones feature is used ensure that the first constant zone motor is connected to Zone 1 and the second constant zone is connected to Zone 2 if applicable 5 Connect the Control Panel into the Primary Wall Panel Port using the red cable provided Connect the second Control Panel into the Secondary Wall Panel port if applicable 6 Set the number of active zones dipswitch in accor dance with the number of zones installed l e if 4 zones system is installed ACTIVATE ON DOWN dipswitch 4 ONLY Dipswitches 1 2 3 5 and 6 need to be in the OFF UP position T If necessary set the Number of Programmed Con stant Zones 0 Programmed Constant 1 The system will ensure ther
2. II ics CLIP IN CONTROLLER ar DAMPER MOTOR BEDROOM 2 BEIGE CABLE RED CABLE RED CABLE SECOND WALL CONTROL PANEL OPTIONAL ee SET NUMBER OF ACTIVE ZONES ees PROGRAMMED CONSTANTS 10I 2 S uoz RDC PROTECTED SWITCHED SOCKET UP TO 6 POWER SUPPLY ZONES p DIAGRAM 1 ZONE STATION 2 CONNECTION SCHEMATICS REVISION 28 08 03 I ZSII 3 ZONE STATION CONTROLS ZONE STATION II USER MANUAL AdvantageAir TYPICAL 6 ZONES CONTROL PANEL LIGHTS LOUNGE DINING KITCHEN GAMES BEDROOM 1 l BEDROOM 2 RESET GETTING STARTED 1 On the CONTROL PANEL select the zones which require air conditioning by pressing the appropriate buttons Zones which are ON are indicated by illuminated LIGHT S 2 Switch OFF zones which do not require air conditioning 3 Not all zone switches are available for use If 4 zones system is installed only the first 4 switches will be activated by the system REVISION 28 08 03 ZONE SWITCHES OPERATION Depending the setup of the system mini mum number of ON zones may need to be maintained for safe operation of the A C system If the minimum number of ON zone s are not maintained the system will automatically over ride the appropriate zone s e If the system does not respond to a command due to a power surge reinitialise the system by pressing the RESET switch lt 5 ZONE STATION II
3. ZONE STATION Advantage Air TYPICAL DAMPER ACTUATOR TYPICAL CONTROL PANEL TYPICAL CONTROL BOX TYPICAL CABLE m FEATURES l APPLICATIONS l e Provides occupant with independent zoning Suitable for all ducted reverse cycle heating e Up to 6 zones can be installed on one system and evaporative air conditioning systems which e Simple to use touch pad control panel are designed with more zones than the A C unit e Up to 2 control panels can be connected for two Capacity allows storey application or large home e Lights on control panel indicate which zones are switched on e Printed labels are provided for easy customization of zone labeling OPTIONS e Can be set to automatically maintain the minimum number of open zones which can eliminate the e Additional control panel and red cable need to be need for constant zone ordered separately Uses clip in 24V damper actuators Can be set on site to facilitate nil one or two All damper motors are pre installed and tested on constant zones Advantage Air Exact Air fittings e Nominated constants can easily be changed e Can be easily retrofitted to an existing system e Can be configured to run Day Night mode using only 1 motor PACKING LIST When ordering Zone Station II kit contains the a 610 A B TYPICAL CONTROL fp s 1 X 252 CONTROL BOX PANEL i 1 1 252 CONTROL PANEL 1 12 METRE RED CABLE 1 X POWER SUPPLY LOW
4. e is at least 1 zone opened at anytime Will utilise zone no 1 2 The system will ensure there are at least 2 zones opened at anytime Will utilise zone no 1 and 2 8 Power up the system 9 Checklist If 4 zones system is installed a The first 4 lights on the control panel s will illuminate b All 4 zone motors will drive to the default fully open position C Green System OK LED inside the Control Box will flash approximately every second d owitch the zones on off to ensure the mo tors operate correctly Label the zones with e f the stickers provided If Number of Programmed Constant is 1 constant switch all zones off en sure Zone 1 is automatically activated after 3 seconds 2 constants switch all zones off en sure Zone 1 and 2 are automatically activated after 3 seconds If necessary press the RESET button to re initialise the system 10 Label the zones on the control panel using the labels provided 11 Optional DAY NIGHT Setting A On the Control Box set the Number of Active Zones to 1 DOWN Ensure all other switches are OFF UP Connect motor onto Zone 1 Press Reset on the Control Panel On the Control Panel label Zone 1 and 2 with Day and Night accordingly REVISION 28 08 03 I ZSII 2 ZONE STATION CONTROLS ZONE STATION II INSTALLATION INSTRUCTIONS ZONE STATION II LOUNGE KITCHEN 24V GREY ZONE STATION

Download Pdf Manuals

image

Related Search

Related Contents

User Manual    1 はじめに  Le nouveau spa professionnel de Jacuzzi avec hydromassage  Harbor Freight Tools Palm Air Nailer Product manual  411ZA/811ZA/611ZA Quick Start Guide  Remington CI52W0 hair curler  LOBE PUMP    dentronix - Aurum Group  

Copyright © All rights reserved.
Failed to retrieve file