Home
FASTCAM NI DAQ software option
Contents
1. ww N ha o N Les 4 frame Chapter 3 Using the FASTCAM NI DAQ software option 3 8 1 Settings for Graphic Display of Waveform Data After download of waveform input data or by right clicking on the graph and clicking Graph Setup the Graph Setup dialog box appears In the Graph Setup dialog box parameters such as the width color and gradient for the graph can be set Graph Setup Window No 01 Ju Analog Digital Select All Channel Color Scheme Y Unit Channel Line Style Slope Y Intercept Device On Off Camera No 1 Analog A M 1 000000 0 000000 On Off Camera No 1 Analog B N 1 000000 0 000000 On Off Camera No 1 Analog C o 110 1 000000 0 000000 M 1 000000 0 000000 On off Camera No 1 Analog D Axis T Unit Legends Min Max frame MV On off T 1818 Y Auto Scaling Iv Y Current Current Bar 7 Y Axis Min Y 0 01 01 V Auto Scaling Center Y Axis Max T Axis Min Sets Hide Unhide for the recorded data Shows the name of the camera that has recorded waveform data The name can be changed by double clicking on it Shows the style of lines to display graph color type width etc of lines A right click can change line styles A right click can change units A right click can change slope values Y Intercept Shows the Y intercept of displayed data A right
2. oooccccccccooncnncccnoooo 4 Chapter 2 Installing the FASTCAM NI DAQ software option 5 2 1 Installing the FASTCAM NI DAQ software option ccccccccccccccccccconnncccnnnnnnnncnnnononnnnnnnnnos 6 2 2 Installing USB driver software for NI DAQ oooooooccccccnccncccccccnncconnnnnanancnnnnnnnnnnnnnononnnnnnnnnnos 9 Chapter 3 Using the FASTCAM NI DAQ software option 15 3 1 Recording work TOW saciar dotan 16 3 2 Connecting PO and NI DAQ issicinnoiasositni isidro 17 3 3 Connecting FASTCAM and NI DAQ Manual Trigger occcccccccccocnnonnnncnnnnnnnnnncncnononnos 20 3 4 Connecting FASTCAM and NI DAQ Level Trigger cccccccccccooococcconanoccncnnnnnonononnnnnnnos 21 33 FACCOLCINIG MAJE earn pida da ita 22 3 5 1 Setting the Frame Rate occoooonncnccccconcncoccnonconcnonnnncnnnononancnnnononnnnnnnnnnnnnnnnnnnnnnnnnnnnnanens 22 3 5 2 Setting the Shutter Speed oooccccccccccconnccnnncccccnooonncnnnonononnonanennnononnnannnnnnnnnnnnnnnanennnns 23 Jas SONG me IMOger ModE cociccocsnianecinca loo aa a a ia A EE 24 3 5 4 Trigger Mode Ty DCS vemos tanicnccia aorta diia 27 3 6 Setting the Wave input board bar ooocccccccccccococcnnncnnnncononononncnnnnnnonnnnncnnnnnononnnaannnnnnnnnnos 30 3 7 Inputting a Rec Start trigger ccccccccocononcconnnccoconoonncnnnnnnononnnennnnnononnonancnnnnnonnnnnnnnnnnnnnons 36 3 8 Graphic Display of Waveform Input Data oonccnccccocccnncccconcnnncnonancnnncnnnancnnonnnnnennn
3. m Axis T Unit m Legends Min Max frame 7 M on off T fo 1818 I Auto Scaling IV Y Current E Current Bar 7 Y Axis Min Y 0 01 fo 01 V Auto Scaling Center Y Axis Max T T Axis Min OK Cancel TT Axis Max 2 Click Line style and select a color style and width from the displayed list Setting can also be made by right clicking on the Line style column of selected channels Graph Setup Window No 01 ed an JIE Device Channel Line Style E sini Style Camera No 1 Analog B Width o 0 000000 Camera No 1 Analog C 0 000000 Camera No 1 Analog D 1 000000 0 000000 Axis T Unit Legends Min Max frame y M On Off T fo 1818 V Auto Scaling IV Y Current Current Bar TY Axis Min Y 0 01 0 01 I Auto Scaling Center Y Axis Max T T Axis Min OK Cancel T T Axis Max 42 3 8 4 Setting Display Unit Gradient and Segment 4 Click the Conversion factor button Graph Setup Window No 01 o h oy io Select Device Channel E i Analog A v On Off Camera No 1 Analog B a 1 000000 0 000000 On Off Camera No 1 Analog C oe 1 000000 0 000000 On Off Camera No 1 Analog D 1 000000 0 000000 m Axis T Unit Legends Mn Max frame y M On Off T fo 1818 MV Auto Scaling MV Y Current Current Bar A Y Axis Min Y 0 01 0 01 IV Auto Scaling 7 Center 7
4. Chapter 2 Installing the FASTCAM NI DAQsoftware option 3 Specify the installation location The default setting for the installation location is as follows C Program Files National Instruments If necessary click Browse and specify another location Click Next Wl NI DAQmx 9 3 5 tination Directory i Y Wy NATIONAL lect the primary installation directory y INSTRUMENTS To change the default folder for installing National Instruments software click the Browse button and select another folder ou can select individual component locations in the next dialog Destination Directory C Program Files National Instruments TO Ge ET 4 Select an install option Select Typical and click Next Lal NI DAQ mx 9 3 5 ct Installation Option y B Wir NATIONAL lect one of the following options INSTRUMENTS 5 Custom Select the individual features to install ale Oo Caa cle TA 10 Confirmation process of product information begins If your PC is connected to an outside network there may be a case where certain relevant information is displayed Li NI DAOmx 9 3 5 uct Notifications Y NATIONAL taller will now check for new notifications P INSTRUMENTS Contacting notification server l License agreement window is displayed Check the content and select I accept the above 4 License Agreement s and click Next La NEDAQmx9 3 5 at accept the licenses displayed be
5. APFIO 0 32 1 Sampling Sets options related to sampling Samples frame Select from the list how many points of data to acquire in 1 frame The sampling frequency is set according to this value and the camera s frame rate When setting a desired sampling frequency select Off Clock Type Select the clock type Internal Internal clock operates with waveform input board s internal clock External External clock operates with the rise or fall of an externally input clock signal When using an external clock you must also set the sampling frequency of the signal to input When setting the external clock s sampling frequency matched to the camera s V Sync output frequency check Sync Camera V Sync For normal operation it is recommended to select External and check Sync with camera V sync Number of Sampling Sets the number of samplings If Auto Setup is checked this setting is automatically calculated from the sampling frequency frame rate and recording frame count If an alert is displayed adjust manually Inout Method Indicates the connection method for analog input signal Choose one from Referenced Single Ended Non referenced Single Ended and Differential e f the waveform input board is set to a sampling frequency that is not possible in the specification it is automatically set to an approximate value Y Supplement e If Samples frame is set to
6. Off sampling frequencies that fulfill the below conditions are displayed in the Sampling Frequency list Integral multiple of the frame rate Input board specification 33 FASTCAM NI DAQ software option Chapter 3 Using the FASTCAM NI DAQ software option 2 Alert An alert is issued here when a problematic setting has been made Use the displayed information for problem soving and or asking Photron for help 3 Channel Selects channels to use Beware of the decrease in measurable sampling speed as the number of channels increases 4 Option Sets a collaborative method with the camera Use RecPos Signal Check this item to use the camera start signal issued by camera to control the measurement sequence of NI DAQ system This item is mutually exclusive against Use Analog trigger to trigger the camera Auto Setup Most of other settings are automatically made by checking this item Basically it is recommended to keep this item always checked Use Analog trigger Check this item if you wish to have the camera triggered by sending a start to trigger the camera signal issued at detection of a trigger based on input voltage to NI DAQ This item is mutually exclusive against Use RecPos Signal 5 External Output Use this item when you wish to have various signals output by NI DAQ If Trigger camera with analog trigger signal is chosen at Option Trigger output PF15 will be
7. e 6 7 n center mode In end mode Memory 26 3 5 4 Trigger Mode Types Camera Data Save Fle View View styles C Cameratree Standard style Start Center End Manual shading Lew tight gt i Camera Option gt Save Setup j Record Option C Variable e Display Snapshot Comment 3 Live Stop Live Memory Record Eare e Trigger modes available and displayed are dependent on the camera model e An error will result if a trigger mode that is NOT supported is chosen for shooting E Start Mode In start mode recording starts at the same time the trigger is input This mode is suitable for recording a high speed phenomenon where the events start point is known in advance This mode records until the maximum recordable frame count camera memory capacity Example For a camera that can record 2 seconds in total 2 seconds of high speed images are recorded directly after the Trigger In button is clicked Record Trigger In el FASTCAM NI DAQ software option Chapter 3 Using the FASTCAM NI DAQ software option E Center Mode In center mode the content directly before and after when the trigger is input is recorded This mode is suitable for recording before and after an important moment This mode records until the maximum recordable frame count camera memory capacity The before and after fram
8. Select All Delete All Sampling Frequency 20000 00 Hz Channel Name Live v _ Dev 1 si0 Dev 1 ai0 10000 Hz JDevijait Dewifail O Dev 1 ai2 Dev 1 ai2 Clock Type Internal x O Devi ai3 Dew1 ai3 7 Syne Camera Y Sync O Dev1 ai4 Devi ai4 Number of Sampling 27270 ODevi ai5 Devi ais DJ Devij ai6 Devijaid Input Method Differential kd ODev1 aiz Dev 1 ai7 Input Range 10 to 10V Live Start Option External Cut I Use RecPos Signal V Auto Setup I Trigger Out FT Sync Out 7 Use Analog trigger to trigger the camera PFIS PFI4 External In Terminal Stop Trigger In PFIO 31 FASTCAM NI DAQ software option Chapter 3 Using the FASTCAM NI DAQ software option 6 Settings for the waveform input board are shown below Channel Samples frame 10 Channel Select All Delete All Sampling Frequency 10000 00 Hz ChannelName Live v Devifai0 Devifai0 10000 Hz E Q Devi ail Dev1 ail l Dev 1 ai2 Devifai2 Clock Type Internal x Q Dev1 ai3 Devifai3 PO Sync Camera Y Sync DJ Devifai4 Devi ai4 Mumber of Sampling 27270 O Dev 1 ai5 Dey 1 ai5 Dev1 ai6 Dey 1 ai6 Ciia Method Differential C Dev1 ai7 Dev 1 ai Upton e Use RecPos Signal Auto Setup Trigger Out Syne Out Use Analog trigger to trigger the camera PFIS PFI4 Stop Trigger In PFIO Level Channel start Software 3 vI APFIO Post Trigger Delay stop External Down 3 v
9. Update Service 2 0 NI I D Trace 3 0 NI Measurement amp Automation Explorer 5 0 HI Network Browser 5 0 0 Click the Mest button to begin installation Click the Back button to change the installation settings Installation of driver software begins It may take around 30 minutes to install depending on the PC s performance HI NEDAQmx 9 3 5 Y NATIONAL E INSTRUMENTS Overall Progress 56 Complete cir ne 13 FASTCAM NI DAQ software option Chapter 2 Installing the FASTCAM NI DAQsoftware option 4 Below window appears when driver software installation is finished Li NI DAQms 9 3 5 allation Complete le Y NATIONAL 9 P INSTRUMENTS The features in this installation have been successfully updated You may be prompted to reboot after dismissing this dialog lt lt Back Finish 2 Below window appears prompting reboot of the PC Click Restart to restart the PC NI DAQrmx 9 3 5 You must restart your computer to complete this operation ff you need to install hardware now shut down the computer If you choose to restart later restart your computer before running any of this sofware e To use FASTCAM NI DAQ software option to control NI DAQ USB driver software included on the NI DAQGmx X X X installation DVD or the latest USB driver software downloaded from the National instruments web site must be used The latest USB driver software for NI DAQ and installation
10. Y Axis Max TT Axis Min OK Cancel T Axis Max 2 Seta unit from the Y Unit list and click the OK button Select user and set any value User Y Unit Y Y A Slope x 80 Intercept e Slope and Y Intercept can be set to each channel independently A unit cannot be set independently on each channel One same unit is set and reflected on all channels 43 FASTCAM NI DAQ software option Chapter 3 Using the FASTCAM NI DAQ software option 3 8 5 Setting Range of Graphic Display Axis scale or calibrations A range of display can be set Check the Auto Scaling checkbox of T field and the time axis range of the displayed graph is interlocked with the playback range on the play control panel Check the Auto Scaling checkbox of Y field the Y axis range is automatically controlled and readjusted so that all the data in the Y direction can be displayed Graph Setup Window No 01 a Ea Camera No 1 Analog B Camera No 1 Analog C Camera No 1 Analog D 1 0 0 000000 1 000000 0 000000 1 000000 0 000000 MAXIS T Unit q Legends Min Max frame y V on off UT fo 1818 Auto Scaling z L Y Y Current Current Bar TY Axis Min Y 0 01 0 01 Auto Scaling 7 Center Y Axis Max TT Axis Min Cancel T Axis Max 9 T Unit The unit for the time axis set is set
11. click can change intercept values 40 3 8 2 Changing the Channel Name 4 Select the channel to change and click the Channel button Graph Setup Window No 01 a aaa Analog Digital Select All Channel Line Style Co Color Scheme Device Channel Line Style Y Unit Slope Y Intercept Analog A a 1 000000 0 000000 Analog B Sa 1 000000 0 000000 1 000000 0 000000 1 000000 0 000000 Camera No 1 Camera No 1 Camera No 1 Analog C Camera No 1 Analog D T Unit m Legends Min Max frame Y On off T fo 1818 IV Auto Scaling Y Y Current Current Bar TY Axis Min Y 0 04 UnA Iv Auto Scaling E Center E Y Axis Max 1 T Axis Min Axis 2 Enter the desired name in Channel Name and click the OK button The channel name is reset to the original channel name displayed in Channel by clicking the Reset button All the channel names are reset by clicking the Reset All button Channel name editor poe So Channel Channel Name Analog A Analog A Reset Reset All m 41 FASTCAM NI DAQ software option Chapter 3 Using the FASTCAM NI DAQ software option 3 8 3 Setting Style of Displayed Graph 4 Click on the channel where setting should take place Graph Setup Window No 01 ms Analog Digital Select All Camera No 1 Analog C 1 000000 0 000000 Camera No 1 Analog D 1 000000 0 000000
12. option Install the FASTCAM NI DAQ software option using the following procedure e Before installing the FASTCAM NI DAQ software option it is necessary to install PFV e FASTCAM NI DAQ software option supports PFV Ver 3 3 6 or later HA Reference e For the PFV installation procedure see 1 2 Setup of the PHOTRON FASTCAM Viewer User Manual 4 Place the FASTCAM NI DAQ software option installation CD in the CD or DVD drive and then open the CD or DVD drive from the computer 2 Onthe CD or DVD drive open the Setup32 folder and then double click the file Setup exe The setup program starts and then the following dialog box appears Click Next Photron FASTCAM NI DAQ option software InstallShield Wizard Welcome to the InstallShield Wizard for Photron FASTCAM NI DAQ option software The InstallShield Wizard will install Photron FASTCAM NI DAG option software on your computer To continue click Next install Shield lt Back Next gt e For 64 bit OS start Setup exe in the Setup64 folder 3 The user license agreement appears Confirm the contents and then click Yes License Agreement Please read the following license agreement carefully Press the PAGE DOWN key to see the rest of the agreement BOUND BY THE TERMS OF THIS LICENSE This Software License Agreement A4greement hereinafter is lawfully made between Photron Limited
13. unit Connecting terminals are located on the top Connect the power adapter cable to 11 30VDC 20W terminal on the main unit Turn the outer shell clockwise to lock i 17 FASTCAM NI DAQ software option Chapter 3 Using the FASTCAM NI DAQ software option 3 Plug the male connector B type on the attached USB cable into female USB receptacle B type on the main unit 4 Plug the male connector A type on the attached USB cable into female USB receptacle A type on PC Connect the AC adapter power cable to NI DAQ unit Plug the AC cord from the adapter to AC outlet Turn on power switch of NI DAQ unit Green LED lights on upper right corner of the main unit The NI DAQ should be detected by PC at this point Installation of the NI DAQ will automatically be completed if the driver software is properly installed by 2 2 Installing USB driver software for NI DAQ 1 Driver Software Installation Your device is ready to use NI Ethernet Device Enumerator Sez rching preconfigured driver folders USB 6251 BNC y Ready to use 19 FASTCAM NI DAQ software option Chapter 3 Using the FASTCAM NI DAQ software option 3 3 Connecting FASTCAM and NI DAQ Manual Trigger This section discusses settings for manual shooting using the REC button on the PFV Connect between your F
14. warnings necessary for using the FASTCAM NI DAQ software option Please read the entire manual before using the software If any part of this manual is unclear contact Photron using the contact information printed at the back of this manual Manual Notation The following icons and symbols are used in the explanations in this manual Icon Symbol Description a Supplement This symbol indicates supplementary items to be aware of when using the software This symbol indicates the location of a reference 0 Important This symbol indicates content that should always be read This symbol indicates instructions that should always be 0 Caution followed when using the software or things to be careful of when using the software This symbol indicates a space for you to use for making notes os This symbol is used to indicate the names of items on a screen references dialog names and keyboard keys e This symbol is used to indicate screen names button names and menu names This symbol is used to explain operating procedures in lt gt diagrams and supplementary items La Table of Contents Chapter 1 Overview of the FASTCAM NI DAQ software option 1 1 1 Overview of the FASTCAM NI DAQ Software Option ooooooonnnnnccccnnnncccccnononnannnnnnnnnnnnnnos 2 1 2 Operating environment of the FASTCAM NI DAQ software Option ccccccoooonccnncccccccom o 3 1 3 Included accessories of the FASTCAM NI DAQ software Option
15. 07 Fax 81 3 3238 2109 E mail image photron co jp 96 Photron FASTCAM Viewer for High Speed Digital Imaging FASTCAM NI DAQ software option User s Manual Revision 1 01E Publication Date January 2013 Publisher PHOTRON LIMITED Chiyoda Fujimi Bldg Fujimi 1 1 8 Chiyoda ku Tokyo 102 0071 2013 PHOTRON LIMITED All rights reserved Printed in Japan No J130111U
16. 9 Option xX_ o 48 4 Specify a frame range to be stored using the Output frame range window Export data E Output data type ls CsvTypeA CSVTypeB Camera List Camera No 1 export OK For TEMA gt Select source e Analog A e Analog B M Analog W Analog D Output frame range I Digital El z 1818 O 1BIT Separate GBIT value 1 879000 18195 Option gp o Select an output format by Output data type check data type checkboxes and click the Export button Export data p Sov Output data type CsvTypeA CSVTypeB Camera List Camera No 1 export OK For TEMA m Select source e Analog A e Analog B V Analog IW Analog D Output frame range T Digital E 0 1815 O IBT Separate 6617 value 1 879000 18195 Option ao D HA Reference e For the CSV output format refer to 8 9 CSV File Structure in the PFV User s Manual 49 FASTCAM NI DAQ software option Chapter 3 Using the FASTCAM NI DAQ software option Specify the file name and the storage to store the file in and click the Save button sue A E Save in E Documents 7 ey Ed Name Date modif Type Size Tags Lo Photron File name cam_001_McdiData Save as type CSV File csv CSW After export is done click the OK button Click the Close button of the Graph dat
17. ASTCAM and NI DAQ as shown below before using the FASTCAM NI DAQ software option 7 el pl ed Proton FAST CAM Pier USB cable Gigabit LAN cable Control PC Trigger Signal PFIO General Out RecPos Sync Signal PFI General Out2 Sync Pos DAQ High speed camera NI USB 6251 BNC FASTCAM i _ ition i e When connecting FASTCAM and PC to the NI DAQ use either the cables included with FASTCAM and NI DAQ or the BNC and USB cables included with the FASTCAM NI DAQ software option e For the above Gigabit LAN connection use network terminals compatible with 1000Base T Gigabit Ethernet and cables compatible with Enhanced category 5 CAT5e or higher only e START CENTER END and MANUAL trigger modes can only be used for manual shooting No other modes are available for use e To use a manual trigger a pre trigger period of 2 frames or more is needed 20 0 3 4 Connecting FASTCAM and NI DAQ Level Trigger This section discusses settings for shooting that uses the input level difference of waveform data acquired by NI DAQ higher or lower than a predetermined voltage level as a trigger Connect between your FASTCAM and NI DAQ as shown below before using the FASTCAM NI DAQ software option USB cable ela Gigabit LAN cable Pianina DEI Viewer la i k A Controll PC 2500 4000 20 16 Trigger Signal loo PFI5 TRIGGER TTL IN 99 Sync Signal PFI General
18. C features operation of up to 1 25M samples s its operation in FASTCAM NI DAQ software option is limited to 1M samples s 1 2 Operating environment of the FASTCAM NI DAQ software option T FASTCAM NI DAQ software option can be run with the following OS environments high speed cameras and waveform measuring instruments e OS gt Windows XP 32 bit or 64 bit version gt Windows Vista 32 bit or 64 bit version gt Windows 7 32 bit or 64 bit version e High speed camera gt VVVVVVV VV VV FASTCAM SA X FASTCAM SA1 FASTCAM SA1 1 FASTCAM SA2 FASTCAM SA3 FASTCAM SA4 FASTCAM SA5 FASTCAM SA6 FASTCAM SA7 FASTCAM MH4 10K FASTCAM MC2 FASTCAM MC2 1 Waveform measuring instrument gt PFV NI USB 6251 BNC National Instruments gt Ver 3 3 6 32 bit 64 bit version or later FASTCAM NI DAQ software option Chapter 1 Overview of the FASTCAM NI DAQ softawre option 1 3 Included accessories of the FASTCAM NI DAQ software option E The FASTCAM NI DAQ software option includes the following accessories FASTCAM NI DAQ software option installation CD One FASTCAM NI DAQ software option User s Manual this manual One 3 Photron FASTCAM Viewer Installation DVD One 4 BNC cable 1 5m Two Chapter 2 Installing the FASTCAM NI DAQ software option 9 FASTCAM NI DAQ software option Chapter 2 Installing the FASTCAM NI DAQsoftware option 2 1 Installing the FASTCAM NI DAQ software
19. FASTCAM NI DAQ software option User s Manual Revision 1 01E Photron e The copyright of this manual is held by Photron Limited e Product specifications and manual contents can change without advanced notification e This manual was created taking every possible measure to ensure the accuracy of its contents However if you find a section which is unclear a mistake or an omission please contact Photron Limited using the contact information provided at the end of the manual e Photron Limited bears no responsibility for the results of using the product or from following the instructions in this manual e The official name of Windows is the Microsoft Windows Operating System e Microsoft Windows Windows XP Windows Vista Windows 7 are registered trademarks or trademarks in the United States and other countries of Microsoft Corporation of the United States e Pentium is a registered trademark of Intel Corporation of the United States e National Instruments NI ni com are the registered trademark of National Instruments in the United States US and in other countries e Other company names and product names listed in this manual are trademarks of their respective companies e Product specifications and features can change for the purpose of improvement without notification is Introduction Thank you for purchasing your FASTCAM NI DAQ software option This manual contains the operating instructions and
20. Graph Setup Window No 01 Line Style Y Unit Analog A Camera No 1 Analog B Camera No 1 Analog C Camera No 1 Analog D 1 000000 0 000000 1 000000 0 000000 1 000000 0 000000 Axis Legends gt Y On Off Min Max T fo 1818 Y Auto Scaling V Y Current E 7 TY Axis Min Y 0 01 0 01 I Auto Scaling 7 Y Axis Max T Axis Min ox Cancel T Axis Max 44 9 Display of current bar Check the Center checkbox and the current bar is fixed in the center of the display screen In usual playback operations the image display screen and the current bar on the graph are displayed interlocked with each other When Center is checked only the maximum value of the time axis can be changed the minimum value is fixed at 0 Graph Setup Window No 01 pi analog C Digital seectal Chamel Line Style Conversion factor Color Scheme Device Channel Line Style Y Unit Slope Y Intercept Camera No 1 Ni 1 000000 Camera No 1 Analog B m 1 000000 0 000000 Camera No 1 Analog C D 1 000000 0 000000 Camera No 1 Analog D E 1 000000 0 000000 Axis Legends Y on off Min Max UT o 1618 Auto Scaling V Y Current p rent Bar T Y Axis Min Y 0 01 0 01 Auto Scaling IV Center 7 Y Axis Max TT Axis Min OK Cancel T Axis Max Legends When On Off is checked the legend window i
21. Out2 Sync Pos DAQ High speed camera NI USB 6251 BNC APFIO FASTCAM Reference Signal e When connecting FASTCAM and PC to the NI DAQ use either the cables included with FASTCAM and NI DAQ or the BNC and USB cables included with the FASTCAM NI DAQ software option e For the above Gigabit LAN connection use network terminals compatible with 1000Base T Gigabit Ethernet and cables compatible with Enhanced category 5 CAT5e or higher only e For a Level Trigger shooting use a signal input to APF 10 or Dev1 ai0 15 terminal to determine the level difference However if a signal to one of Dev1 ai0 15 terminals is used no other terminals cannot be used So the use of APF10 terminal is recommended e CENTER END and MANUAL trigger modes can only be used for Level trigger shooting No other modes are available for use e To use input level triggering a pre trigger period of 2 frames or more is needed 21 FASTCAM NI DAQ software option Chapter 3 Using the FASTCAM NI DAQ software option 3 5 Recording Image 3 5 1 Setting the Frame Rate The conditions for the shot such as the frame rate shutter and resolution must be set before recording the subject Shot conditions for the camera are set from the Camera tab on the control panel PPP IOCU pa frame sec 1024 1024 To set the frame rate or the resolution disp
22. Photron hereinafter and the customer User hereinafter who has purchased a software product sold by Photron Software hereinafter to which this Agreement is attached In this Agreement this Software means the computer software and the media containing it land all related documentation manuals in printed and or electronic forms Only if the User has agreed to the terms and conditions presented in this Agreement the User may use this Software As soon as the User has installed this Software in PC the User is deemed to have lagreed to this Agreement f1 Intelectual Property Rights BT hem ilone PA PA deme blo wk these M a AAA AAA of lomme AAA Do you accept all the terms of the preceding License Agreement If you select No the setup will close To install Photron FASTCAM NI DAG option software you must accept this agreement Install 4 Specify the installation location The default setting for the installation location is as follows C Program Files PHOTRON Photron FASTCAM Viewer 3 If necessary click Browse and specify another location Click Next Photron FASTCAM NI DAQ option software InstallShield Wizard l Choose Destination Location Select folder where setup will install files Setup will install Photron FASTCAM NI DAQ option software in the following folder To install to this folder click Next To install to a different folder click Browse and select another fol
23. a output dialog box to close it 50 Chapter 4 Alert Display 91 FASTCAM NI DAQ software option Chapter 3 Using the FASTCAM NI DAQ software option When there is an error in a waveform input board setting the Alert button on the waveform input board bar is displayed in red If you click the Alert button a message box is displayed and you can confirm the content of the alert This error is also displayed in Alert on the Analog Board Setup dialog box When Auto Setup is checked an alert may be displayed when the frame rate or resolution is changed Open Sampling Frequency Live Close 62500 000000 hz E Setup Error Display Error Content Frequency Over The sampling frequency exceeds the range that can be set Samples frame not integer error The sampling frequency is not an integral multiple of the frame rate Frequency change Error The intended sampling frequency was not set The sampling frequency has been set with the nearest possible value Number of Sampling Over The number of samples exceeds the value that can be set Camera Trigger mode Error The present trigger mode cannot be synchronized with the waveform input board Channel Error The number of channels that can be set has been exceeded 92 Chapter 5 Specifications 53 FASTCAM NI DAQ software option Chapter 5 Specifications Product specification serves as the following 10V 5V 2V 1V 05V 0 2V 0 1V S
24. ampling rate 1 00 MS s It divides at two or more times of ch use 286 W x 170 H x 69 D mm Excluding protrusions 42 302 1 2kg Operating temperature 0 to 45 C Storage temperture 20 to 70 C Humidity 10 to 90 No Condensation Pollution degree 2 Overvoltage category 94 Chapter 6 Contacting Photron 99 FASTCAM NI DAQ software option Chapter 6 Contacting Photron For inquires related to PFV contact Photron at the contact information listed below Additionally the following items will be verified when inquiring so please prepare them in advance Contact Information Product Name Company school or organization name customer contact name contact phone number contact e mail The Photron FASTCAM Viewer version number and the high speed camera name For the version number check the version information Condition of the system and what is known about it In Americas and Antipodes In Europe Africa and India In other areas PHOTRON USA INC 9520 Padgett Street Suite 110 San Diego CA 92126 4426 USA Phone 800 585 2129 or 858 684 3555 Fax 858 684 3558 E mail image photron com www photron com PHOTRON EUROPE LIMITED The Barn Bottom Road West Wycombe Buckinghamshire HP14 4BS U K Phone 44 0 1494 48 1011 Fax 44 0 1494 48 7011 E mail image photron com www photron com PHOTRON LIMITED Fujimi 1 1 8 Chiyoda Ku Tokyo 102 0071 Japan Phone 81 3 3238 21
25. cheked automatically 6 External Input Indicates which signal should best be input to which terminal 7 Trigger Conditions Settings to have camera work in collaboration with NI DAQ When both Auto setup and Use RecPos Signal are checked no display is made because all items are atutomatically set e Touse Use Analog trigger to trigger the camera be sure to make a test shooting to confirm proper operation This is vitally important because the camera fails to start shooting if there is even the slightest error in setting 34 Start Sets the recording start and stop conditions Software Input the trigger in conjunction with the PFV Record button External Down External trigger falls External Up External trigger rises Stop When the specified number of samples is obtained stop trigger only voltage level set in Level in the rising direction Level Down When the voltage input to the channel passed the voltage level set in Level in the falling direction Channel When Level Up or Level Down is specified for trigger condition Start or Stop a channel is assigned to accept input analog signal which is to be used as analog trigger signal For a Level Trigger shooting either APF10 or Dev1 ai0 15 may be specified However the use of APF 10 terminal is recommended basically Post Trigger Deley Enter the delay count From the input of the trigger start end the actual sam
26. clicked 0 5 seconds before and 1 5 seconds after the input 2 seconds of high speed images are recorded lf frame rate is 1000 If frame rate is 1000 frame sec frame sec The specified 1 5s 1500 frames recorded the specified 0 5s 1500 frames recorded Record Ready Recording When recording in manual mode the settings below must be made in prior to beginning the recording 1 Click the Trigger Mode button and select Manual Camera Data Save File View View styles C Camera tree Standard style Camera Camera No 1 V Show info oo Edit info Y Start Head eac Setup Staph Center Frame Rate Shutter End Shading OW ie Random Partition Update Random Reset Camera Option Save Setup Random Center Record Option Variable Random Manual Display Snapshot Comment Two Sta ge 1 2 live Stop Live Memory Two Sta ge 1 4 Record Two Stage 1 8 2 Specify the frame count to record before and after the trigger input Drag the Total Frames slider or enter the frame count directly When the setting is finished click the Close button Total Frames 5457 7 Before trigger 1364 frame p5 00 After trigger 4093 frame 75 00 29 FASTCAM NI DAQ software option Chapter 3 Using the FASTCAM NI DAQ software option 3 6 Setting the Wave input board bar a Set up the PFV waveform port bar Before starting PFV make sure that FASTCAM NI DAQ and co
27. der Destination Folder C Program Files Photron Photron FASTCAM Viewer 3 InstallShield lt Back Cancel e For directory for installation be sure to specify a folder where Photron FASTCAM Viewer 3 has been installed 7 FASTCAM NI DAQ software option Chapter 2 Installing the FASTCAM NI DAQsoftware option Installation starts When installation is finished the following screen appears Click Finish mere tron FASTCAM NI DAQ option software InstallShield Wiz InstallShield Wizard Complete The InstallShield Wizard has successfully installed Photron FASTCA4M NI DAQ option software Click Finish to exit the wizard InstallShield 2 2 Installing USB driver software for NI DAQ To use FASTCAM NI DAQ software option to control NI DAQ USB driver software must be installed in advance Install the USB driver software using the following procedure Y The NI DAQmx X X X DVD comes with NI DAQ Place the DVD in the DVD drive 2 Setup program starts up and the below dialog appears Click Install NI DAQmx X X X ni com dataacquisition NI DAQ Data Acquisition Driver Software View Device Documentation Explore the Media AA NATIONAL 52011 National Instruments All rights reserved INSTRUMENTS a Supplement e X X X in the above description indicates the version number 9 FASTCAM NI DAQ software option
28. e count are equal Example For a camera that can record 2 seconds in total After clicking Trigger In the system is in the record loop state when Endless Rec is clicked 1 second before and 1 second after the trigger is input a total of 2 seconds of high speed images is racnrdad Record Trigger In Endless Rec 1000 frames sec 1000 frames sec lf frame rate is 1000 frames sec then 2000 frames recorded E End Mode In end mode the content directly before the trigger is input is recorded This mode is suitable for recording an important phenomenon for which it is difficult to predict when the event will begin and end This mode records until the maximum recordable frame count camera memory capacity Example For a camera that can record 2 seconds in total After clicking Trigger In the system is in the record loop state when Endless Rec is clicked 2 seconds of high speed images before the input are recorded Endless Rec 28 m Manual Mode Similar to center mode this mode records the content directly before and after when the trigger is input In center mode the proportion of the recording before and after the trigger input is equal but in manual mode the proportion Seconds or frames recorded before and after the important moment can be set to the desired value Example For a camera that can record 2 seconds in total After clicking Trigger In the system is in the record loop state when Endless Rec is
29. ed data for display Graph Setup Window No 01 Rh Y eism Analog Digital Select All Channel Line Style Conversion Factor Device Channel i i Slope Y Intercept Camera No 1 Analog A a 1 000000 0 000000 Camera No 1 Analog B ES 1 000000 0 000000 Camera No 1 Analog C A 1 000000 0 000000 Camera No 1 Analog D 1 000000 0 000000 Axis pT Unit Legends Min Max frame ad v On Off T 0 1818 Y Auto Scaling V Y Current Current Bar TY Axis Min 0 01 fo 01 V Auto Scaling Center 7 Y Axis Max L T T Axis Min Cancel T Axis Max 38 Select channels to display Check the desired channels in the Select column and click the OK button Graph Setup Window No 01 esm Conversion Factor _Slope Analog A 1 000000 0 000000 Analog B a 1 000000 0 000000 Analog C Sonn 1 000000 0 000000 Analog D 1 000000 0 000000 T Unit Legends frame y Y On off IV Y Current Bar 7 Y Axis Min I Center 7 Y Axis Max TT Axis Min 7 T Axis Max Graph is displayed An example of graphically displayed analog waveform data 1 A 4 I gt YOKOGAWA CH1 Y Current 5 17333 YOKOGAWA CH2 Y Current 5 02667 v T O frame O index 4 5 4 3 5 3 2 5 2 1 5 39 FASTCAM NI DAQ software option
30. hreshold input level to the NI DAQ system or by START STOP buttons Features of the FASTCAM NI DAQ software option 1 Integrated adjustment of both high soeed cameras and waveform measuring instruments The FASTCAM NI DAQ software option was designed to be used as a plug in for Photron FASTCAM Viewer hereafter referred to as PFV the camera control software for FASTCAM From this plug in software it is possible to perform integrated adjustment of both FASTCAM and NI DAQ The FASTCAM NI DAQ software option imports the image recording settings of FASTCAM and then automatically sets NI DAQ so that it matches with the image recording time of FASTCAM Furthermore by saving FASTCAM image data and NI DAQ waveform data at a discretionary location with the same name it is possible to view data after recording 2 Includes cables and connectors for simultaneous operation The product is packaged with the cables and connectors necessary for the simultaneous operation of FASTCAM and NI DAQ This means that even new users can easily perform setup Y Supplement e For information regarding applications involving FASTCAM NI DAQ software option please send your request to Photron or to your nearby Photron dealer e If you have any questions regarding NI DAQ please contact National Instruments e FASTCAM NI DAQ software option is plug in software and cannot be run in isolation PFV must be acquired separately e Though the NI USB 6251 BN
31. ist The list displayed differs depending on the camera model AutoExposure Y 1 frame sec 1 2000 sec 1 3000 sec 1 4000 sec 1 5000 sec 1 6000 sec 1 7000 sec 1 8000 sec 1 9000 sec 1 10000 sec 1 12000 sec 1 15000 sec 1 17000 sec 1 20000 sec 1 25000 sec 1 30000 sec 1 34000 sec 1 39000 sec 1 50000 sec 1 57000 sec 1 62000 sec 1 74000 sec 1 82000 sec 1 92000 sec 1 104000 sec 1 178000 sec 1 333000 sec 1 593000 sec 1 1000000 sec 1 2700000 sec 23 FASTCAM NI DAQ software option Chapter 3 Using the FASTCAM NI DAQ software option 3 5 3 Setting the Trigger Mode Depending on the trigger mode set the timing of the frames when they are recorded and the number of frames recorded on the camera when the trigger signal is input will differ e Trigger modes that FASTCAM NI DAQ software option supports are START CENTER END and MANUAL a total of four trigger modes e When using a level triggering method START trigger mode is NOT available for use e When using CENTER END or MANUAL mode an error is issued if a pre trigger period is not used completely Relationship Diagram for the Trigger Modes and Recorded Frames Trigger Signal gt B z pi pala e B Frame Ki Start mode Center mode Manual mode End mode lt gt Recorded frames 24 Record Button Use the Record button on the control panel to start recording The name of the Record button change
32. l CHAN Ec se Agreement le PA rs NATIONAL INSTRUMENTS SOFTWARE LICENSE AGREEMENT 4 NSTALLATION NOTICE THIS IS A CONTRACT BEFORE YOU DOWNLOAD THE SOFTWARE AND OR COMPLETE THE INSTALLATION PROCESS CAREFULLY READ THIS AGREEMENT BY DOWNLOADING THE SOFTWARE AND OR CLICKING THE APPLICABLE BUTTON TO COMPLETE THE INSTALLATION PROCESS YOU CONSENT TO THE TERMS OF THIS AGREEMENT AND YOU AGREE TO BE BOUND BY THIS AGREEMENT IF YOU DO NOT WISH TO BECOME A PARTY TO THIS AGREEMENT AND BE BOUND BY ALL OF ITS TERMS AND CONDITIONS CLICK THE APPROPRIATE BUTTON TO CANCEL THE INSTALLATION PROCESS DO NOT INSTALL OR USE THE SOFTWARE AND RETURN THE SOFTWARE WITHIN THIRTY 30 DAYS OF RECEIPT OF THE SOFTWARE WITH ALL ACCOMPANYING WRITTEN MATFRIALS Al ONG WITH THEIR CONTAINERS TO THF PLACE YOU ORTAINED The software to which this National Instruments license applies 12 NI DAGms 9 3 5 do not accept all these License Agreements AO cee ET 11 FASTCAM NI DAQ software option Chapter 2 Installing the FASTCAM NI DAQsoftware option License agreement widow is displayed again Check the content and select I accept the above 2 Licenses Agreement s and click next 15 NI DAQmx 9 3 5 Agreement y wy NATIONAL ust accept the licenses displayed below to h INSTRUMENTS Microsoft Silverlight EULA MICROSOFT SOFTWARE LICENSE TERMS MICROSOFT SILVERLIGHT 4 These license terms are an agreement between Microsoft Corporation for based on where yo
33. lay the Camera tab on the control panel The frame rate setting can be selected from the list by clicking the Frame Rate button The resolution setting can be selected from the list by clicking the Resolution button The list displayed varies depending on camera model vaihe Verible Y IO iD 60 fps 1024 306 151 50 7 10H 752 0 ips Camera Data Save File View eerie S as vf a Vi styles A IH 512 2000 fps ne 2506 1 AG 20004 106175 2000 tps Cameratree Standard style at elo 164 ed Camera Camera No 1 gt I Showinfo sil ip ak Edit info Tis T 400 tps eed fa 1641640 6250 fps Setup arapi AA BOO fps ono 5000 ips Frame Rate Shutter PAE 10000 fps a 6 12000 ft Resolution ld S120 512 15000 fps S12 5 a 16000 fips Shading Low Light S120 352 0000 ipe e Lint S120 128 20000 fps Partition Update don fips 3 Wii WHH Ee 9 e Camera Option Save Setup Wix PAD lps PA oe a BOO fra 5 7 Record Option Variable dn 286 100000 fps z T fps 156 1 135 7 Snapshot Comment ae 180000 pa Display 153 108 50000 4 i i E C live Stop Live Memory 128100 300000 fps ep find 450000 fet PSN peace imi 300000 fps sisal Bix i 673000 fps 5416 22 3 5 2 Setting the Shutter Speed Display the Camera tab on the control panel and click on the Shutter button a list of shutter speeds that can be set on the connected camera will be displayed Select the desired speed from the l
34. manuals can be acquired from the following website http www ni com support Chapter 3 Using the FASTCAM NI DAQ software option 15 FASTCAM NI DAQ software option Chapter 3 Using the FASTCAM NI DAQ software option 3 1 Recording work flow EEE Use the following procedure to use the FASTCAM NI DAQ software option to record and save FASTCAM image data and NI DAQ waveform data or playback graphs and images in synchronization Connect PCand NI DAQ using the specified connection method See 3 2 Connecting PC and NI DAQ Connect FASTCAM and NI DAQ using the specified connection method See 3 3 Connecting FASTCAM and NI DAQ Manual Trigger or 3 4 Connecting FASTCAM and NI DAQ Level Trigger Using PFV set the various image recording settings including FASTCAM frame rate shutter speed and trigger mode See 3 5 Recording Image Using the Synchronized Navigater Window of the FASTCAM NI DAQ software option set NI DAQ to match the FASTCAM image recording settings See 3 6 Setting the Wave input board bar Recording by FASTCAM and NI DAQ See 3 7 Inputting a Rec Start trigger After completion of recording by FASTCAM and NI DAQ the image data recorded by FASTCAM can be played back using PFV See 3 8 Graphic Display of Waveform Input Data 3 2 Connecting PC and NI DAQ o Before using the FASTCAM NI DAQ software option connect PC and NI DAQ using the following method 4 Prepare the NI USB 6251 USB main
35. nal is sent to the camera from the waveform input board appropriately set up to certain conditions at Trigger setting The camera should be set in advance for Trigger In or for Endless Rec by REC button Camera Data Save File View View styles y C Camera tree Standard style Y Show info Edit info Camera Camera No 1 Head Head No 1 v Setup Graph s Frame Rate Shutter l Resolution l if EE Made j e N e Partition Ii Update ENEE Orton Save Setup l RECT Option l Wariable Display Snapshot Comment Live Stop e Live Prema endless RS Rec Done 36 3 8 Graphic Display of Waveform Input Data This step sets the camera to graphically display external data at a recording After recording have the Camera tab displayed on the control panel and within the Camera tab select the camera that has recorded the waveform input data to be replayed 37 FASTCAM NI DAQ software option Chapter 3 Using the FASTCAM NI DAQ software option 3 Click the Graph button Note however if waveform input data has not been recorded during the recording this button is grayed out ea O LLD rr Am A AS 3 The desired data is downloaded and Graph Setup dialog box is displayed The camera name or waveform input board name that captured the waveform input data is displayed in Device Check Analog to select the record
36. nss 37 3 8 1 Settings for Graphic Display of Waveform Data oocccnccccconccnccccccnnncnonannnnncnonanonns 40 3 8 2 Changing the Channel Name oocccnccccnccccnccnnncccncnonccnnnnnnonononnncnnnnnononannnnnnnnnnnnnonanenenss 41 3 8 3 Setting Style of Displayed Graph oooooccccnncccccconccnnnnnononnnonncnnnnnonononanncnnnnnnononanennnss 42 3 8 4 Setting Display Unit Gradient and SegMent oooooonccnccccncnnoncccnnncnnnnonanncnnnnnconananenenos 43 3 8 5 Setting Range of Graphic Display ccccccccoccnnccnonocononononncnnnnnononnnanncnnnnnnonononennnss 44 3 8 6 Graph View WindO0W occcccccconncnncccnooncnncocnnconnconnnncnnnonnnnnnnnnonnnnnrnnnnnnnnnrnnnnnnnnnnnnnonanenns 46 J67 Onno GO VOTA Cestas biie lala 48 Chapter 4 Alert Display 51 Chapter 5 Specifications 53 Chapter 6 Contacting Photron 55 Chapter 1 Overview of the FASTCAM NI DAQ software option nn 1 FASTCAM NI DAQ software option Chapter 1 Overview of the FASTCAM NI DAQ softawre option 1 1 Overview of the FASTCAM NI DAQ software option LLL EEK KO With the FASTCAM NI DAQ software option it is possible to use NI USB 6251 BNC waveform measuring instruments by National Instruments hereafter referred to as NI DAQ to simultaneously record analog signals along with images from FASTCAM high speed digital cameras by Photron hereafter referred to as FASTCAM and playback graphs and images in synchronization The camera may be operated by using a t
37. ntrol PC are properly connected and powered up 4 Press START button then All programs Photron FASTCAM Viewer 3 and PFV Ver 3 Or double click PF Y button on the desktop 2 PFV starts up Input waveform board bar is displayed if FASTCAM NI DAQ software option is installed properly 2909 2999GIH99DIVIVOSIIOI Q Coma ta Soe Ple View aoe atla Cop F rd a u ESAS sce i piris Teup Froma Pinte Thier 1 Wes a Input Board Feiler Tagger Meds sadn LW Uae Paros a a i Corea Oper Sere Ses Record Opari Trabe Y Supplement e f the waveform input board bar is not displayed click View Waveform Input Board Bar on the menu 3 Click the Open button on the waveform input board fy y Photron FASTCAM Viewer File View Option Window Help PRE PERE 30 4 With Select Device select the NIDAQ Select a board to use from the list displayed in Device Name and click the OK button Select Device x Select Device NIDAQ Device Name rename Devi Cancel a Supplement e The name to be displayed in Device name should be the same as what is shown in Measurement amp Automation To change the device name see the relevant section in NI DAQ manual Analog Board Setup dialog is displayed Make necessary settings on NI DAQ Channel Samples frame 10 Channel
38. pling of data delayed by the amount of the delay count entered here e When Auto Setup is checked the settings change in conjunction with changes in the camera settings e APF10 or terminals Dev1 ai0 15 may be specified as a channel for input level detection However if one of Dev1 ai0 15 terminals is specified ONLY that specified channl can be used for measuring input voltage 35 FASTCAM NI DAQ software option Chapter 3 Using the FASTCAM NI DAQ software option 3 7 Inputting a Rec Start trigger To start a recording on the FASTCAM camera in collaboration with NI DAQ there are two different ways 4 To start measurement on NI DAQ at a start trigger signal issued by the camera by pressing the Record button on the PFV The whole operation starts going on when the Record button is pressed on PFV The NI DAQ system automatically starts and ends its measurement cycle Camera Data Save Fie View View styles Cameratres Standard style Camera Camera No 1 Iv Show info _ Edit info Graph _ Frame Rate Shutter Resolution Trigger Mode shading Lew Light Partition Update Camera Option 1 Save Setup Record Option Variable Display Snapshot Comment C Live Stop Live C Memory Re rd f Cancel 2 To trigger camera for shooting at an input level trigger issued by the NI DAQ A trigger sig
39. raph can move the position of the current bar A mouse drag in the vertical or horizontal direction along the Y axis or T axis respectively changes the display area Ei Graph Window No 01 Al b Camera No cu sCurrent 5 47 Camera No4JCurrent bar rrent 3 05 Camera No HTETO drrent 1 Camera No 1 Metal D Current 1 TAM Me N AA ti amen in im i Mt i nt a 0 WA 47 FASTCAM NI DAQ software option Chapter 3 Using the FASTCAM NI DAQ software option 3 8 7 Storing in CSV format 4 Graphically display the waveform input data that you wish to store in the PC 2 Right click on the graph and select Export Data B Graph Window No 01 al alali Camera No 1 Analog amp Y Current 1 88 Camera No 1 Analog B Y Current 3 97 Camera No 1 Analog Y Current 1 Camera No l Analog D Y Current 1 Y T 2 frame 5lindex ii Se fa re E Graph Setup TAH lift MUU TE LITT AS i rin LA a i Y NR A AAA Bl EA AS 400 500 frame 3 The Export data dialog box is displayed From Camera List select the camera or waveform input board that captured the data to save Export data muero Camera List Output data type Camera No 1 export OK CSVTypeA CSVTypeB For TEMA Close r Select source W Analog A V Analog B V Analog E M Analog D Output frame range Digital H 0 S 1815 EST O 1BIT Separate 6BIT value 1 819000 181
40. s according to the camera s state The button name indicates the current state Record Trigger In Endless Rec RECA Ready Recording Endless Record ARRE Record Enters the record ready standby state when clicked Recording does not start Trigger In Starts recording when clicked The system enters the endless recording state and continues recording until the trigger is input When the storage capacity is surpassed it overwrites and continues recording The trigger is input when clicked The scene is recorded according to the trigger mode set using when the trigger was input as the baseline Endless Rec The trigger is input with the Trigger In button in standard mode 25 FASTCAM NI DAQ software option Chapter 3 Using the FASTCAM NI DAQ software option m Endless Record When the images directly before the trigger signal input are recorded recording with center mode manual mode end mode endless recording is performed When the memory capacity is surpassed the frames are overwritten An example for a camera that can record four frames Endless record starts i Trigger input y 51316 Frames recorded in memory Endless record starts Memory Camera 6 i E KK BBE XXX X Ke When the memory capacity is surpassed the old frames are overwritten and the new frames are recorded X is an overwritten frame After the trigger signal is input the frames that are ultimately recorded de 4
41. s displayed The information provided by legend covers the maximum and minimum values and the current value Graph Setup Window No 01 UN i i Y 1 000001 Camera No 1 Analog B o 1 000000 0 000000 Camera No 1 Analog C a 1 000000 0 000000 Camera No 1 Analog D gram 1 000000 0 000000 Axis T Unit f Legends Min Max frame M On Off T o 1818 Auto Scaling Y Y Current p rent Bar T Y Axis Min Y 0 01 0 01 Auto Scaling IV Center 7 Y Axis Max 7 T Axis Min OK Panal i l T Axis Max 45 FASTCAM NI DAQ software option Chapter 3 Using the FASTCAM NI DAQ software option 3 8 6 Graph View Window Graph View Window Button Functions You can set the following with the buttons on the graph view window A Graph Window No 01 H A 4 le Camera No 1 Analog Y Current 0 88 Camera No l Analog E Y Current 2 95 Camera No l dnalog Y Current 1 Camera No l Analog D Y Current 1 T Olframe Olindex Area Zoom After clicking this button drag the cursor drawing a rectangle over the portion of the graph area to display and the specified area is enlarged Frame Rewind Rewinds the frame by the data point unit index unit when clicked Frame Advance Advances the frame by the data point unit index unit when clicked 46 9 Adjustment display area A mouse drag in the horizontal direction on the g
42. u live one of its affiliates and you Please read them They apply to the software named above which includes the media on which you received it if any The terms also apply to any Microsoft updates including but not limited to bug fixes patches updates upgrades enhancements new versions and successors to the software collectively called undated The software to which this third party license applies i distributed with NI DAG ms 9 3 5 5 do not accept all these License Agreements Trust confirmation window toward the driver software is displayed Check the content and select Always trust software from National Instruments Corporation and click Next Lal NI DAOmx 9 3 5 er Software Installation 3 Wir NATIONAL ways trust software from National Instruments l INSTRUMENTS This installer includes driver software signed by National Instruments Leave the box below checked for an uninterupted installation f you uncheck the box your installation may be intemupted by one or more Microsoft Windows secunty dialogs Always trust software from National Instruments Corporation 12 A group of software applications being installed are displayed Click Next La NEDAQmx 9 3 5 Installation E Wir NATIONAL view the Following summary before continuing INSTRUMENTS Adding or Changing NI DA0ms 9 3 5 NI M s Configuration Support Application Development Support NI LabVIEW SignalE xpress 2011 HI