Home

RPC-6010G Rackmount LCD Workstation Page i

image

Contents

1. Figure 5 1 PSU External Retention Screws Step 7 Remove the two internal retention screws that secure the PSU assembly to the right side panel of the workstation Figure 5 2 nn o Figure 5 2 PSU Internal Retention Screws RPC 6010G Rackmount LCD Workstation Step 8 tO Corp Remove the retention screws on the PSU mounting bracket Figure 5 3 Figure 5 3 PSU Mounting Bracket Retention Screws Step 9 Step 10 Step 11 Step 12 Step 13 Step 14 Step 15 Reattach the PSU mounting bracket to the new PSU with the two previously removed retention screws Install the new PSU into the workstation making sure the PSU power connector and PSU cooling fan are facing out of the workstation Reinsert the two previously removed internal retention screws that secure the PSU assembly to the right side panel of the workstation Reinsert the four previously removed external retention screws that secure the PSU assembly to the rear panel of the workstation Reinstall the CPU card clamp Reinstall the top cover of the workstation Reinstall the workstation into the rack Refer to Section 4 6 for complete mounting instructions lechnology Corp RPC 6010G Rackmount LCD Workstation 5 6 Cooling Fan Replacement To replace a cooling fa
2. Level 0 1 Value Main Display Features Menu Brightness 0 to 100 Contrast 0 to 100 Horizontal Size 0 to 100 Phase 0 to 100 H Position 0 to 100 V Position 0 to 100 Sharpness 1to5 Speaker Volume This menu is currently disabled Mute and will be implemented with models equipped with speakers Color Menu 9300 Preset NTSC value 7500 Preset NTSC value User RGB values from 0 to 100 Language Menu English Select French German Spanish Italian Japanese Russian Traditional Chinese Simplified Chinese OSD Menu OSD Time Out to 60 sec OSD Position 1105 050 0 10 100 Auto Setting On or Off Recall No or Yes Aspect Ratio 4 3 or 5 4 e RPC 6010G Rackmount LCD Workstation Table 6 1 OSD Menus 6 2 Using the OSD OSD menu options are described below 6 2 1 Main Display Features Main display features are shown in Figure 6 2 Brightness Contrast Clock Phase H Position V Position Sharpness Figure 6 2 Main Display Features Level 0 Level 1 Value Signal Menu Digital Select Analog Backlight Menu Light Enable On or Off Light Contrast 0 to 100 Light Brightness 0 to 100 Light H Start 0 to 100 Light H Width 0 to 100 Light V Start 0 to 100 Light V Height 0 to 100 1 RIechnology Corp RPC 6010G Rackmount LCD Workstation m Br
3. 18 4 1 2 Installation 18 2 2 UNPACKING tt ecieece a 19 LN 19 4 2 2 Unpacking Procedure 19 lechnology Corp 423 Packing D M PHOT REN 20 4 3 PRE INSTALLATION PREPARATION REP CE 22 4 3 1 System Planning 22 22 4 4 INSTALLATION PROCEDURES 23 4 4 1 Preinstalled Components esses esent enne nnne 23 4 4 2 User Installed 23 4 4 3 PV LC 23 4 5 INSTALLING COMPONENTS INTO THE 60100 eee 24 4 5 1 Remove the 25 4 5 2 Remove the CPU 26 4 5 3 Remove the Dual CPU Card Clamp amp Drive Bay Stabilizer Bracket 26 4 5 4 Remove the Drive 28 4 5 5 Remove the Drive Slot Blank Plate sss 28 4 3 6 Install Driv MM TNT TENSION 29 4501522 Disk Dii 29 4 56 23 57 Disk Driyeana 5 257 oen 30
4. 16 Packing List 21 OSD MONS CE 62 lt a Corp RPC 6010G Rackmount LCD Workstation Chapter 1 Introduction lechnology Corp 1 1 RPC 6010G Overview RPC 6010G Rackmount LCD Workstation The RPC 6010G is a PC AT compatible computer designed for industrial applications It has a rugged steel chassis specially designed to work under harsh environmental conditions while also being high reliability The RPC 6010G supports 14 slot passive backplanes ATX motherboards and a full line of dependable AC DC power supplies The RPC 6010G can withstand shock vibration dust and a wide range of temperatures in industrial environments A lockable door protects drive bays and switches from unauthorized misuse and dust The RPC 6010G also has two removable cooling fans installed in the front panel for optimum cooling of the system 1 2 RPC 6010G Features Some of the features of the RPC 6010G include m 8 4 TFT LCD with fully functional OSD and membrane keypads m Flexible driver combination m Lockable front door USB x2 on the front panel m PICMG 1 3 backplane and Redundant power supply support m Advanced air flow design 1 3 Model Variations The RPC 6010G comes in a variety of models The models have special features as identified by their
5. J IEI Technology Corp 8 4 TFT LCD AU 14 slot Rackmount LCD Workstation User Manual Rev 1 0 December 2006 I Technology Corp RPC 6010G Rackmount LCD Workstation Revision MODEL RPC6010G Rackmount Workstation Revision Number Description Date of Issue 1 0 Initial release December 2006 RPC 6010G Rackmount LCD Workstation Corp Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior notice in order to improve reliability design and function and does not represent a commitment on the part of the manufacturer In no event will the manufacturer be liable for direct indirect special incidental or consequential damages arising out of the use or inability to use the product or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copyright rights are reserved No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of the manufacturer TRADEMARKS IBM PC is a registered trademark of International Business Machines Corporation INTEL is a registered trademark of INTEL Corporation Other product names mentioned herein are used for identification purposes only and may be trademarks and or registered trademarks
6. lt Back Cancel Figure 7 9 Program Icon Directory 26 RPC 6010G Rackmount LCD Workstation Step 13 The program then starts installing Figure 7 10 Setup Status TouchKit Setup is performing the requested operations Now copying files C Program Files T ouchkit xT ouchMon exe InstallShield Cancel Figure 7 10 Installing IEI RIechnology Corp RPC 6010G Rackmount LCD Workstation Step 14 Once the program is finished installing the user is prompted to restart the computer now or to restart the computer later Figure 7 11 Select when the computer should be restarted and click FINISH to complete the driver installation procedure Setup Complete Setup has finished installing TouchKit on your computer No will restart my computer later The TouchkKit driver has been installed To ensure proper operation the computer needs to be restarted Figure 7 11 Installation Complete 7 3 Touch Screen Driver Configuration To configure the touch screen driver options refer to the TouchKit user manual located on the driver installation CD O gt RJ Technology Corp RPC 6010G Rackmount LCD Workstation THIS PAGE IS INTENTIONALLY LEFT BLANK Page 80 m TN lt a RIechnology Corp RPC 6010G Rackmount LCD Workstation Appe
7. Digital Figure 6 6 Signal Menu e RPC 6010G Rackmount LCD Workstation 6 2 6 Backlight The Backlight menu in Figure 6 7 enables users to configure the LCD backlight Brightness Light Contrast Light Brightness Light H Start Light H Width Light V Start Light V Height Figure 6 7 Backlight Menu Backlight Menu options are described below m Light Enabled Turns backlight on or off m Light Contrast Adjusts the backlight contrast m Light Brightness Adjusts the backlight brightness m Light H Start Adjusts the backlight projection area in the horizontal direction m Light H Width Adjusts the width of the backlight projection area m Light V Start Adjusts the backlight projection area in the vertical direction m Light V Height Adjusts the height of the backlight projection area lt a RIechnology Corp RPC 6010G Rackmount LCD Workstation Chapter T Software Driver lechnology Corp The following information is provided for workstations with touch screens RPC 6010G Rackmount LCD Workstation 7 1 Touch Screen Driver The touch screen controller enables analog resistive touch screens for four wire five wire amp eight wire models The controller directly communicates with the PC system through the touch screen communications interface The controller design is superior in s
8. 61 6 2 USING THE ER Fe 62 6 2 1 Main Display 62 64 PEE DU CH H 65 6 2 4 OSD Configurations 66 TU S THEE 67 TH Tern 68 7 SOFTWARE 69 7 1 TOUCH SCREEN 70 7 2 DRIVER 4000000000000 71 7 3 TOUCH SCREEN DRIVER 0 00000 0 79 Ux UO Uo Ua in 81 ROHS COMPLIANT 82 B RECOMMENDED IEI BACKPLANES MOTHERBOARDS AND PSUS 83 RECOMMENDED BACKPLANES AND MOTHERBOARDS eene 84 B 2 RECOMMENDED POWER SUPPLY 8 85 INDEX 87 Page vii Page viii lechnology Corp RPC 6010G Rackmount LCD Workstation List of Figures Figure 2 1 RPC 6010G Front 6 Figure 2 2 RPC 6010G Front Panel Door Open eene 7 Figure 2 3 RPC 6010G 14 Slot Rear Panel 8 Figure 2 4 RPC 6010G ATX Motherboard Rear 9 Figure 2 5 RP
9. Power 300W PFC Active Hold up Time 17ms minimum Efficiency 65 50 000hrs Temperature 0 50 C Operating 20 80 C Storage Dimensions 140 x 150 x 86mm Table 3 3 ACE 832AP PSU Specifications 3 4 Recommended IEI Backplanes Motherboards and PSUs Refer to Appendix B for recommended IEI backplanes motherboards and power supply units for the RPC 6010G rackmount workstation lt a Corp RPC 6010G Rackmount LCD Workstation Chapter 4 Installation lechnology Corp RPC 6010G Rackmount LCD Workstation 4 1 Installation Considerations 4 1 1 Installation Precautions When installing the RPC 6010G please follow the precautions listed below Read the user manual The user manual provides a complete description of the RPC 6010G rackmount workstation installation instructions and configuration options Turn Off Power When installing the RPC 6010G rackmount workstation make sure the power is off Failing to turn off the power may cause severe injury to the user and or damage the system Certified Engineers Only certified engineers and technicians should install and modify the RPC 6010G rackmount workstation Non certified engineers or technicians should not attempt to install the RPC 6010G rackmount workstation Mounting The RPC 6010G rackmount workstations are heavy devices When
10. Remove the dual CPU card clamp and drive bay stabilizer bracket See Section 4 5 3 Disconnect all cabling from every hard drive Remove the drive bracket see Section 4 5 4 Remove the retention screws that secure the 3 5 disk drive to the drive bracket and slide the drive out of the bracket Install the new 3 5 disk drive See Section 4 5 6 3 Reinstall the drive bracket to the workstation See Section 4 5 7 Reconnect all disk drive cabling Close the top cover of the workstation and reinstall the workstation into the cabinet or rack in which it was previously installed Refer to Section 4 6 for complete mounting instructions lechnology Corp 5 7 2 5 25 Disk Drive Replacement RPC 6010G Rackmount LCD Workstation To replace a 5 25 disk drive please follow the instructions below 4 Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 Step 11 Step 12 NOTE These instructions are also applicable for replacement of a 3 5 disk drive mounted in a 5 25 disk drive adapter bracket Refer to Section 4 5 6 2 for instructions on installing a 3 5 disk drive into a 5 25 drive bay slot Turn off and disconnect the workstation from all power sources Remove the workstation from the rack in which it is installed Open the top cover of the RPC 6010G rackmount workstation See Section 4 5 1 Remove the CPU card clamp See Section
11. e RPC 6010G Rackmount LCD Workstation Step 4 Once the OS system is selected the touch kit setup will prepare the install shield wizard Figure 7 2 which will quide you through the rest of the setup E TouchKit Setup is preparing the InstallShield Wizard process Please wait Figure 7 2 Install Shield Wizard Preparation Step 5 After the Install Shield Wizard is ready a welcome screen appears Figure 7 3 Welcome to TouchKit Setup This program will install TouchKit on your computer It is strongly recommended that you exit all Windows programs before running this Setup program Cancel Figure 7 3 Welcome Screen Step 6 To continue the installation process click NEXT RIechnology Corp RPC 6010G Rackmount LCD Workstation Step 7 An Install PS 2 interface driver screen appears Figure 7 4 It is not necessary to install the PS 2 interface driver To continue click NEXT setup j x Setup Type Choose the setup type that best suits your needs Extra PS 2 interface driver for TouchKit controller Please check the check for PS 2 touch controller InstallShield lt Back Cancel Figure 7 4 Install PS 2 Interface Driver Step 8 Four point calibration options are then selected Figure 7 5 Four point calibrations can be done every time a user boots up during the next time the sy
12. 30 Front Panel es 6 5 25 inch Disk Drive 29 Left Side 10 Backplane ss etre 33 Right Side 9 Connect the Cables 39 Model Variations 2 CPU sed cene 35 Mournitlrigi deerat ee RN 40 Page 88 Packing List 20 Pixel ess 15 Recommended IEI Backplanes and Motherboards 84 Recommended IEI Power Supply Units 85 Resolutiori 15 Response 15 RPC 6010G Rackmount LCD Workstation RITechnology Corp SNOCK d 14 14 Touch Screen Driver 70 Touch Screen Driver Configuration 79 19 Vibra 14 VIEWANGI6 15 16
13. Before closing the top cover make sure the following items have been completed m The backplane is properly installed m The CPU card is properly installed m The PCI ISA expansion cards are properly installed m The disk drives are properly installed into the drive bracket m drive bracket is properly reinstalled into the workstation m All cables are properly connected If all of the above listed items have been properly installed close the top cover and reinsert the previously removed retention screws 4 6 Mounting the RPC 6010G Rackmount Workstation The RPC 6010G workstation can be mounted to the posts of a standard 19 rack cabinet Adequate rails rack tray or side brackets should also be available for supporting the weight of the workstation Make sure that all cabling is correctly attached and carefully routed when installing the workstation NOTE At least two people are required to mount the workstation The rack or cabinet into which the workstation is installed should provide adequate and sufficient ventilation grounding power source and stability features 1 RIechnology Corp RPC 6010G Rackmount LCD Workstation This section gives generic description of the rack mounting process for the RPC 6010G rackmount workstation Alternate rack mounting systems may require different mounting procedures Be sure to follow the manufacturer s instructions when mounting the
14. 4 5 2 Remove the dual CPU card clamp and drive bay stabilizer bracket See Section 4 5 3 Disconnect all cabling from every hard drive Remove the drive bracket see Section 4 5 4 Remove the retention screws that secure the 5 25 disk drive to the drive bracket and slide the drive out of the bracket Install the new 5 25 disk drive See Section 4 5 6 3 Reinstall the drive bracket to the workstation See Section 4 5 7 Reconnect all disk drive cabling Close the top cover of the workstation and reinstall the workstation into the cabinet or rack in which it was previously installed Refer to Section 4 6 for complete mounting instructions Lar RPC 6010G Rackmount LCD Workstation Chapter 6 On Screen Display OSD Controls Page 59 I Technology Corp 6 1 User Mode OSD Structure RPC 6010G Rackmount LCD Workstation 6 1 1 OSD Buttons There are several on screen display OSD control buttons on the front panel of the workstation Figure 6 1 shows a typical arrangement of OSD controls Figure 6 1 OSD Control Buttons Pressing the direction keys LEFT or RIGHT can bring out simple menu adjusts the LCD screen brightness and contrast values 6 1 2 OSD Menu Structure RPC 6010G Rackmount LCD Workstation Table 6 1 shows the OSD menu structure Corp
15. Figure 6 4 Language Menu This menu provides options for selecting ODS screen legends in a preferred language e 6 2 4 OSD Configurations RPC 6010G Rackmount LCD Workstation The OSD configurations are shown in Figure 6 5 OSD Time Out LCA OSD Position 2 34 6 OSD Transparency Jo Auto Setting Off Recall Yes Aspect Ratio 5 4 Figure 6 5 OSD Configurations Menu OSD Configurations are described below m OSD Time Out Determines how many seconds the OSD screen stays on screen before it disappears when OSD is left unattended m OSD Position Adjusts the OSD position on the screen Position 1 is in the upper left of the screen position 2 in the upper right and position 3 in the center OSD Transparency Determines the opacity of OSD background m Auto Setting This function automatically adjusts the LCD screen position in situations such as connecting the LCD to a different host computer m Restores the default OSD settings Note that this will restore all default display settings 2 S KT 1d 2 Corp RPC 6010G Rackmount LCD Workstation m Aspect Ratio Adjusts the display ratio referring to the width of the screen and then to the height of the screen 6 2 5 Signal The Signal menu in Figure 6 6 enables manual selection of the type of graphic source input i e analog 15 pin VGA or digital DVI D ere s
16. Rack Handle Bracket Assembly and Installation 41 Figure 4 17 Remove Rack Slide eese nnn nnn 42 Figure 4 18 Workstation Slide Installation eese 43 Figure 4 19 Rack Slide Bracket Assembly eere 44 Figure 4 20 Rack Slide Bracket Installation eese 45 RPC 6010G Rackmount LCD Workstation RITechnology Corp Figure 4 21 Install Workstation into Rack 46 Figure 5 1 PSU External Retention 5 52 Figure 5 2 PSU Internal Retention Screws 52 Figure 5 3 PSU Mounting Bracket Retention 53 Figure 5 4 Cooling Fan Bracket External Screws eene 55 Figure 5 5 Cooling Fan Bracket Bottom Panel 55 Figure 5 6 Fan Retention Screws 56 Figure 6 1 OSD Control 5 60 Figure 6 2 Main Display 5 62 Figure 6 3 Color 5 64 Figure 6 4 Language Menu 65 Figure 6 5 OSD Configurations 66 Figure 6 6 Signal 6
17. describe the physical layout of the RPC 6010G rackmount workstation 2 1 1 Front Panel The RPC 6010G rackmount workstation has the following front panel items m Plastic frame m 84 panel TFT LCD screen m Lockable drive bay access door with 62 key membrane keypad and OSD controls conceals Three 5 25 drive bays One 3 5 drive bay Power switch 2 USB connectors Power and HDD LEDs Reset button 8 FO F10 2 596 o iT Ti 1 5 Figure 2 1 RPC 6010G Front Panel __ 1 Corp RPC 6010G Rackmount LCD Workstation Figure 2 2 RPC 6010G Front Panel Door Open Drives Not Included 2 1 2 Rear Panel The RPC 6010G rackmount workstation is available with either a 14 slot rear panel bracket or an ATX motherboard rear panel bracket The following sections list the 14 slot rear panel bracket and ATX motherboard rear panel bracket items 2 1 2 1 14 Slot Rear Panel The 14 slot rear panel has the following rear panel items m Internal PSU m 14 expansion slots m VGA connector m 5 2 mouse connector m Optional Touch Screen connector I Technolog
18. rack mounting the RPC 6010G rackmount workstation please ensure that at least two people are assisting with the procedure Anti static Discharge Electronic components like CPU cards and backplanes must be installed into the RPC 6010G rackmount workstation Follow proper grounding procedures before installing these components 4 1 2 Installation Prerequisites Prepare the following before installing the RPC 6010G rackmount workstation Completely installed CPU card The RPC 6010G rackmount workstation CPU card is separately purchased Before installing the RPC 6010G rackmount workstation a CPU card should be properly installed The following components may also have to be installed refer to the user manual that came with the CPU card O CPU Heatsink and cooling fan O O Memory modules DIMMs Compact flash disks I RIechnology Corp m Backplane Motherboard The backplane or motherboard installed the RPC 6010G Rackmount LCD Workstation RPC 6010G rackmount workstation is separately purchased m Disk Drives Disk drives installed into the RPC 6010G rackmount workstation are separately purchased Disk drive support is CPU card dependent Before purchasing a CPU card or disk drives please check the CPU card disk drive support 4 2 Unpacking 4 2 1 Packaging When shipped the RPC 6010G rackmount workstation is wrapped in a plastic bag Two polystyrene ends are placed on either side of the RPC 6010G rac
19. touch kit controller is installed Figure 7 8 The default directory is Files Touchkit If a different folder must be used select browse and then select the folder Once the folder is selected click NEXT to continue setup j x Choose Destination Location Select folder where Setup will install files Setup will install Touchkit in the following folder To install to this folder click Next To install to a different folder click Browse and select another folder Destination Folder C Program ouchKit Browse InstallShield Figure 7 8 Controller Installation Directory RPC 6010G Rackmount LCD Workstation OT 6 1 RIechnology Corp Step 12 The user is then prompted to select a file directory in which the program icons are saved Figure 7 9 The default folder is TouchKit If a different folder must be used select a folder from the list shown Once the folder is selected click to continue setu X j x Select Program Folder Please select a program folder InstallShield Setup will add program icons to the Program Folder listed below may type new folder name or select one from the existing folders list Click Next to continue Program Folders TouchKi Existing Folders Systems Administrative Tools AutoCAD 2002 Autodesk CorelDRAW Graphics Suite IDEUtil Inkscape LanFlow
20. 11 Place the new fan into the bracket Align the retention screw holes in the new fan with those in the bracket and reinsert the four retention screws Step 12 Connect the new cooling fan to the PSU Step 13 Reinstall the three retention screws that secure the cooling fan bracket to the bottom of the workstation Step 14 Reinstall the two external retention screws that secure the cooling fan bracket to the left side panel of the workstation Step 15 Reinstall and reconnect all CPU cards and PCI ISA expansion cards Step 16 Reinstall the dual CPU card clamp and drive bay stabilizer bracket See Section 4 5 3 Step 17 Reinstall the CPU card clamp See Section 4 5 2 RPC 6010G Rackmount LCD Workstation Step 18 Step 19 O I RIechnology Corp Reinstall the top cover of the workstation Reinstall the workstation into the rack Refer to Section 4 6 for complete mounting instructions 5 7 Disk Drive Replacement 5 7 1 3 5 Disk Drive Replacement To replace a 3 5 disk drive please follow the instructions below Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 Step 11 Step 12 Turn off and disconnect the workstation from all power sources Remove the workstation from the rack in which it is installed Open the top cover of the RPC 6010G rackmount workstation See Section 4 5 1 Remove the CPU card clamp See Section 4 5 2
21. 7 Figure 6 7 Backlight Menu 68 Figure 7 1 Driver CD Pop Up 71 Figure 7 2 Install Shield Wizard Preparation esee 72 Figure 7 3 Welcome Screen 72 Figure 7 4 Install PS 2 Interface 73 Figure 7 5 Install PS 2 Interface Driver 74 Figure 7 6 Touch Monitor USB Touch Controller Confirmation 74 Figure 7 7 Controller Installation 75 Figure 7 8 Controller Installation 76 Figure 7 9 Program ICON 77 Figure 7 10 Installirig innt 78 Figure 7 11 Installation Complete 79 I Technology Corp RPC 6010G Rackmount LCD Workstation List of Tables Table 1 1 Table 2 1 Table 3 1 Table 3 2 Table 3 3 Table 4 1 Table 6 1 RPC 6010G Model 3 General Physical 10 RPC 6010G Specifications 14 Specifications 2 iiit ii ete ce nex eR ERR ERR 15 ACE 832AP PSU 8 5
22. C 6010G Right Side Panel eene 9 Figure 2 6 RPC 6010G Left Side Panel 10 Figure 2 7 RPC 6010G Physical Dimensions eene 11 Figure 4 1 Top Cover Left Side Retention Screws esee 25 Figure 4 2 Remove Top Cover from Chassis eene 25 Figure 4 3 CPU Card Clamp Right Side Retention Screws 26 Figure 4 4 Dual CPU Card Clamp Retention 27 Figure 4 5 Dual CPU Card Clamp Fan Bracket Retention Screws 27 Figure 4 6 Drive Bracket Retention Screws 28 Figure 4 7 Drive Slot Blank Plate Retention Screws 29 Figure 4 8 5 25 Disk Drive Retention Screws eese 30 Figure 4 9 3 5 to 5 25 Drive Bay Rack Retention 31 Figure 4 10 3 5 Disk Drive Retention Screws eene 32 Figure 4 11 Install Copper Pillars and Plastic Spacers 33 Figure 4 12 Backplane Retention Screws eene 34 Figure 4 13 Slot Cover Retention Screw 36 Figure 4 14 Install the CPU 37 Figure 4 15 Installing a Short Card eene 39 Figure 4 16
23. RIATIONS eR Eee ED Ee EET 2 1 4 3 MECHANICAL OVERVIEW 3 oic aseo ccec vea s sese esse ee veia eo se ie so ee vaa ice a ve Ge daa 5 2 1 EXTERNAL OVERVIEW 00 0 2 660610 61010 000000000 EET 6 2 front Panels seo 6 2 4 2 Rear Panel 7 2 1 2 1 14 Slot Rear 1 20 0 00200000000000000000 eene 7 2 1 2 2 ATX Motherboard Rear 0780 8 2 1 3 Right Side Tr 9 ER Em 10 2 2 PHYSICAL DIMENSIONS cccccccccccccsssssscecceccesessesseeccecceseaueusescceccessuueuseescecesseeauenens 10 2 2 1 General Physical 10 2 2 2 RPC 6010G Physical Dimensions 11 DETAILED SPECIFICATIONS 13 3 1 RPC 6010G 5 6 00000 14 3 2 LCD SPECIFICATIONS a c eden 15 3 3 ACE 832AP PSU 8 16 3 4 RECOMMENDED BACKPLANES MOTHERBOARDS 08 16 INSTALLATION 17 4 1 INSTALLATION CONSIDERATIONS 000000000 00000 18 4 1 1 Installation
24. Specifications 16 Preinstalled Components 23 Active iic tete 15 18 Remove the CPU Clamp 26 Remove the Drive Bracket 28 Backliglit 5 15 Remove the Drive Slot Blank Plate 28 Brightness 15 Remove the Dual CPU Card Clamp amp Drive Bay Stabilizer 26 secet 25 User Installed Components 23 Certifications 2 2 1 81 Contrast 15 Touch Screen 70 Maintenance 47 Backplane Replacement 50 Cooling Fan Replacement 54 Features eite eee 2 nM M _ Disk Drive 57 d PCI ISA Expansion Card Replacement 49 PSU 51 liput Current tette eto tes 16 Mechanical 5 Inrush 16 14 Slot Rear 7 Installation then 17 ATX Motherboard Rear Panel 8 3 5 inch Disk Drive 31 Dimensions oie 10 3 5 inch Disk Drive in a 5 25 inch Slot
25. TIATX PCI 14S2 RS R30 PICMG 1 0 4 8 0 0 0 PCI 14S3 RS R30 PICMG 1 0 4 9 0 0 0 PX 14S3 RS R30 PICMG 1 0 12 2 0 0 0 AT ATX PX 14S5 RS R30 PICMG 1 0 7 6 0 0 0 AT ATX BP 14S RS R30 ISA 0 14 0 0 0 AT PXAGP 13S3 RS R30 PIAGP 11 0 0 0 0 AT ATX PE 13SD PICMG 1 3 4 0 5 0 2 ATX PXE 13S PICMG 1 3 8 0 3 0 1 1352 1 3 4 0 7 0 1 1383 1 3 3 0 0 8 1 Table B 1 Recommended IEI Backplanes and Motherboards RPC 6010G Rackmount LCD Workstation B 2 Recommended IEI Power Supply Units Corp The following table lists the recommended IEI power supply units for the RPC 6010G rackmount workstation Type Model No Watt AT ACE 935AL RS 300W ACE 940AP RS 390W ATX ACE 832AP RS 250W ACE 841AP RS 480W ACE 850AP RS 500W Redundant ATX ACE R4130AP RS 300W ACE R4140AP RS 400W Table B 2 Recommended IEI Power Supply Units O gt RJ Technology Corp RPC 6010G Rackmount LCD Workstation THIS PAGE IS INTENTIONALLY LEFT BLANK Page 86 A zo RIechnology Corp RPC 6010G Rackmount LCD Workstation Index e lechnology Corp Installation Steps 23 PCI ISA Expansion 37 18 ACE 832AP PSU
26. andle brackets are flush against the rack See Figure 4 21 I Technology Corp N a y mM Y Figure 4 21 Install Workstation into Rack Step 7 If necessary secure the workstation handle brackets to the rack with the fasteners that came with the workstation lt a Corp RPC 6010G Rackmount LCD Workstation Chapter 5 Maintenance RPC 6010G Rackmount LCD Workstation 5 1 Maintenance Overview Maintaining the RPC 6010G rackmount workstation is essential for the smooth operating of system applications Maintaining the system might mean replacing failed components during the lifetime of the workstation The following RPC 6010G components can be replaced m CPU m PCI ISA expansion card m m Power supply unit PSU Cooling fans m Disk drives 3 5 5 25 WARNING Never attempt to remove the external panels or access any internal components of the workstation while it is connected to a power source Always be sure to turn off and disconnect the workstation from all power sources before attempting to access the internal components Failure to do so may seriously injury to the user or cause irreparable damage the internal components of the workstation 5 2 CPU Card Replacement To replace a CPU card please follow the in
27. ate number of retention screws into each side of the 3 5 disk drive through the 3 5 drive bracket Figure 4 10 Figure 4 10 3 5 Disk Drive Retention Screws 4 5 7 Reinstall the Drive Bracket After the drives have been installed reinstall the drive bracket into the chassis It might be easier to connect the disk drive IDE SATA connectors to the ribbon cables and the disk drive power connectors to the PSU before the drive bracket is reinstalled into the chassis Step 1 Remount the drive bracket in the original position it was removed from Step 2 Make sure all drive bracket retention screw holes are properly aligned with the corresponding retention screw holes in the workstation Step 3 Reinsert all drive bracket retentions screws 4 2 1 RIechnology Corp RPC 6010G Rackmount LCD Workstation 4 5 8 Install the Backplane To install a backplane follow the instructions below Step 1 Install the correct amount of copper pillars and plastic spacers into the base of the chassis Figure 4 11 backplane shown Figure 4 11 is an example for reference only location and number of copper pillars and plastic spacers depends on the backplane being used 16 RPC 6010G Rackmount LCD Workstation Step 2 Mount the backplane into the chassis Make sure the backplane is positioned so that when the CPU
28. card and PCI ISA expansion cards are installed both the CPU card and the PCI ISA card I O connectors face the I O brackets on the rear panel Step 3 Align the retention screw holes in the backplane with the copper pillars installed in Step 1 Step 4 Insert retention screws to secure the backplane to the chassis Figure 4 12 Figure 4 12 Backplane Retention Screws Corp RPC 6010G Rackmount LCD Workstation 4 5 9 Install the CPU Card Before a CPU card is inserted into backplane make sure the CPU has been correctly prepared and that all the CPU card jumper settings are configured correctly For CPU card component installation procedures please refer to the user manual that came with the CPU card CAUTION Depending on the location of the CPU card the disk drive ribbon cable connectors and other peripheral device cable connectors may have to be connected to the CPU card before it can be installed To install a CPU card onto the backplane follow the instructions below Step 1 Remove the slot bracket from the chassis rear panel by removing the slot cover retention screw Figure 4 13 RPC 6010G Rackmount LCD Workstation Figure 4 13 Slot Cover Retention Screw Step 2 Remove the CPU card clamp See Section 4 5 2 Step 3 Remove the dual CPU card clamp an
29. ckplane Install the CPU card Install the PCI or ISA expansion cards optional RPC 6010G Rackmount LCD Workstation Step 10 Connect all required cables Step 11 Reinstall the dual CPU card clamp and drive bay stabilizer bracket Step 12 Reinstall the CPU card clamp Step 13 Close the top cover Step 14 Mount the workstation 4 5 Installing Components into the RPC 6010G This section gives a generic description of the component installation process for the RPC 6010G rackmount workstation WARNING Failure to follow the installation procedures outlined in this section may cause severe damage to the RPC 6010G rackmount workstation Please follow the installation instructions carefully 1 RIechnology Corp RPC 6010G Rackmount LCD Workstation 4 5 1 Remove the Top Cover The top cover is secured to the RPC 6010G rackmount workstation with six screws three each on the left and right panels To remove the top cover please follow the steps below Step 1 Remove the six top cover retention screws three each on the left and right panels See Figure 4 1 umm MTM gt 3 D D D Figure 4 1 Top Cover Left Side Retention Screws Right Side Similar Step 2 Remove the top cover from the chassis to reveal the internal components See Figure 4 2 Figure 4 2 R
30. ct all internal and external peripheral device connections from the PCI ISA expansion card Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 Step 11 Step 12 Step 13 RPC 6010G Rackmount LCD Workstation Remove the CPU card clamp See Section 4 5 2 Remove the dual CPU card clamp and drive bay stabilizer bracket See Section 4 5 3 Remove the retention screw that secures the PCI ISA expansion card to the slot on the rear panel Slide the PCI ISA expansion card out of the workstation Install a new PCI ISA expansion card See Section 4 5 10 Reinstall the CPU card clamp Reinstall the dual CPU card clamp and drive bay stabilizer bracket Reinstall the top cover of the workstation Reinstall the workstation into the rack Refer to Section 4 6 for complete mounting instructions 5 4 Backplane Replacement To replace a backplane please follow the instructions below Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Turn off and disconnect the workstation from all power sources Remove the workstation from the rack in which it is installed Open the top cover of the RPC 6010G rackmount workstation See Section 4 5 1 Remove the CPU card clamp See Section 4 5 2 Remove the dual CPU card clamp and drive bay stabilizer bracket See Section 4 5 3 Disconnect and remove all CPU cards see Section 4 5 9 and PCI ISA expansion ca
31. d drive bay stabilizer bracket See Section 4 5 3 Step 4 Slide the CPU card into the reserved PCI ISA socket on the backplane Make sure the back edge of the CPU card slides into the plastic guide rails at the front end of the chassis SSG gt ESTO 3 X em ZN 73 RPC 6010G Rackmount LCD Workstation ZZO 4444s Figure 4 14 Install the CPU Card Step 5 To secure the CPU card reinsert the previously removed slot cover retention screw Step 6 PCI ISA expansion card is not being installed reinstall the dual CPU card clamp and drive bay stabilizer bracket and the CPU card clamp If expansion card is being installed proceed to the next section 4 5 10 Install the PCI ISA Expansion Card To install a PCI expansion card or an ISA expansion card please follow the instructions below Step 1 Remove the slot cover retention screw to remove the slot bracket from the chassis rear panel Figure 4 13 Step 2 Step 3 Step 4 Step 5 Step 1 Step 2 RPC 6010G Rackmount LCD Workstation If necessary remove the CPU card clamp See Section 4 5 2 If necessary remove the dual CPU card clamp and drive bay stabilizer bracket See Section 4 5 3 Slide the PCI ISA expansion card into the reserved PCI ISA soc
32. dic 31 4 5 7 Reinstall the Drive FPEM FEX DATED p ert RE 32 CAPUT HUN E 33 4 3 9 Install th CPU Cari 35 4 5 10 Install the PCI ISA Expansion Card sss 37 4 5 11 Installing Short Cards 38 4 5 12 Connect the 39 4 5 13 Close the Cove PR TETTE 40 4 6 MOUNTING THE RPC 6010G RACKMOUNT WORKSTATION 40 5 2s 47 3 1 MAINTENANCE OVERVIEW E 48 5 2 CPU CARD 5 48 5 3 PCI ISA EXPANSION CARD REPLACEMENT 49 5 4 BACKPLANE REPLACEMENT iriser nate bsc a a 50 3 9 PSU REPLACEMENT ssc T 51 5 6 COOLING PAN REPLACEMENT 54 5 7 DISE DRIVE REPLACEMENT 57 1 O I RIechnology Corp RPC 6010G Rackmount LCD Workstation 5 7 1 3 5 Disk Drive Replacement 57 5 7 2 5 25 Disk Drive 58 6 SCREEN DISPLAY OSD 8 59 6 1 USER MODE OSD 5 004 400 60 6 1 1 OSD 60 6 1 2 OSD Menu Structure
33. e physical dimensions of the RPC 6010G 2 2 1 General Physical Dimensions General physical dimensions for the RPC 6010G are shown in Table 2 1 Width Height Depth mm mm mm 431 177 528 Table 2 1 General Physical Dimensions 1 RIechnology Corp RPC 6010G Rackmount LCD Workstation 2 2 2 RPC 6010G Physical Dimensions The physical dimensions of the RPC 6010G are shown in Figure 2 1 O gt RJ Technology Corp RPC 6010G Rackmount LCD Workstation THIS PAGE IS INTENTIONALLY LEFT BLANK Page 12 TN lt Corp RPC 6010G Rackmount LCD Workstation Chapter 3 Detailed Specifications lechnology Corp 3 1 RPC 6010G Specifications Table 3 1 shows the RPC 6010G specifications LCD Type 8 4 TFT Input Interface VGA Max Resolution 800 x 600 Backlight MTBF 20 000 Hrs Contrast 500 1 LCD Color 262K Brightness cd m2 220 Chassis Heavy duty steel View Angle H V 130 110 050 function Yes Mounting 19 Rack Mount Rack Height 4U Cooling Fan 1 12cm Expansion Slots 14 for RPC 6010G 7 for RPC 6010GATX Dimensions WxHxD mm 431 177 528 Weight 55 15kg 18kg Color White 5 17 Hz 0 1 double amplitude displacement Vibration 17 640 Hz 1 56 acceleration peak to peak S
34. emove Top Cover from Chassis lechnology Corp RPC 6010G Rackmount LCD Workstation 4 5 2 Remove the CPU Card Clamp The CPU card clamp is secured to the RPC 6010G rackmount workstation with four retention screws To remove the CPU card clamp please follow the steps below Step 1 Remove four retention screws two each on the left and right sides of the workstation that secure the CPU card clamp to the chassis Figure 4 3 gt 4 4 amp amp Figure 4 3 CPU Card Clamp Right Side Retention Screws Left Side Similar Step 2 Remove the CPU card clamp from the chassis 4 5 3 Remove the Dual CPU Card Clamp amp Drive Bay Stabilizer Bracket The dual CPU card clamp and drive bay stabilizer bracket is secured to the RPC 6010G rackmount workstation with 10 retention screws To remove the dual CPU card clamp and drive bay stabilizer bracket please follow the steps below Step 1 Remove the six retention screws that secure the dual CPU card clamp and drive bay stabilizer bracket to the sides of the workstation chassis Figure 4 4 RITechnology Corp RPC 6010G Rackmount LCD Workstation 2 _ lt DANSE 14 9 gt o 2 Figure 4 4 Dual CPU Card Clamp and Drive Bay Stabilizer Bracket Right Side Retention Screws Lef
35. ensitivity accuracy and friendly operation The touch screen driver emulates the left mouse button and the right mouse button functions The touch screen driver supports the following operating systems Microsoft Windows versions Microsoft Windows 95 Microsoft Windows 98 Microsoft Windows ME Microsoft Windows 2000 Microsoft Windows NT Microsoft Windows XP Microsoft Windows XP Tablet PC Edition Microsoft Windows CE versions O Microsoft Windows CE 2 12 O Microsoft Windows CE 3 0 O Microsoft Windows CE NET O O O O m Linux m m DOS Driver installation is described below 4 2 1 Corp RPC 6010G Rackmount LCD Workstation 7 2 Driver Installation To install the touch screen software driver please follow the steps below Step 1 Insert the TouchKit driver CD that came with the RPC 6010G rackmount workstation into the CD drive Step 2 Once the CD drive is installed the screen in Figure 7 1 appears Figure 7 1 Driver CD Pop Up Screen Step 3 Select the operating system installed on the system from the menu on the left side of the screen NOTE The following description is for driver installation using a Windows 2000 OS If a different OS is installed please refer to the driver user manual for the relevant OS The driver user manuals can be accessed by selecting User Manual from the menu on the left side of the Driver CD Pop Up Screen
36. ention screws into each side of the 3 5 disk drive through the 3 5 to 5 25 drive bay rack Figure 4 9 EJ a RPC 6010G Rackmount LCD Workstation 1 RIechnology Corp Figure 4 9 3 5 to 5 25 Drive Bay Rack Retention Screws Other Side Similar Step 3 Step 4 Step 5 Step 6 Remove the dual CPU card clamp and drive bay stabilizer bracket from the RPC 6010G rackmount workstation see Section 4 5 3 Remove the drive bracket from the RPC 6010G rackmount workstation see Section 4 5 4 Remove the appropriate drive slot blank plate see Section 4 5 5 Install the 3 5 to 5 25 drive bay rack into the drive bracket see Section 4 5 6 1 4 5 6 3 3 5 Disk Drive To install a 3 5 disk drive follow the instructions below Step 1 Step 2 Step 3 Remove the dual CPU card clamp and drive bay stabilizer bracket from the RPC 6010G rackmount workstation see Section 4 5 3 Remove the drive bracket from the RPC 6010G rackmount workstation see Section 4 5 4 If installing a floppy disk drive remove the 3 5 drive slot blank plate see Section 4 5 5 RPC 6010G Rackmount LCD Workstation Step 4 Slide a 3 5 disk drive into one of the 3 5 drive brackets Make sure the connectors of the drive are facing the rear of the drive bracket Step 5 Insert the appropri
37. hock 10G acceleration peak to peak 11ms Humidity 5 95 relative Operation Temperature 0 50 C Table 3 1 RPC 6010G Specifications RPC 6010G Rackmount LCD Workstation RTechnology Corp RPC 6010G Rackmount LCD Workstation 3 2 LCD Specifications Table 3 2 lists the RPC 6010G LCD specifications Size 8 4 MFR Model AUO G084SNO03 Resolution SVGA 800 x 600 Active Area mm 170 4 x 127 8 Pixel Pitch mm 0 213 Number of Colors 262K View Angle H V 130 110 Brightness cd m2 220 Contrast Ratio 500 1 Response Time ms at 25C 35 Power Consumption W 3 3 Interface ich LVDS Supply Voltage V 3 3 Backlight 1 CCFL Lamp Life hrs 20 000 Table 3 2 LCD Specifications lechnology Corp 3 3 ACE 832AP PSU Specifications RPC 6010G Rackmount LCD Workstation Table 3 3 lists the ACE 832AP power supply specifications INPUT Voltage 90 264VAC Full Range Frequency 50 60Hz Input Current 6A RMS 115VAC 3A RMS 230VAC Inrush Current 60A Max for 115VAC 90A Max for 230VAC OUTPUT Voltage Min load load Ripple amp Noise 3 3V 0 3A 28A 50mV 5V 0 1A 30A 50mV 12V 15 120mv 0 3A 100mv 12V 0A 0 8A 120mv 5Vsb 2 100mv Total Current of 3 3V amp 5 amp 12 lt 280W GENERAL
38. ify the system before the system is installed This ensures that prudent selections can be made when the system is being developed 4 3 2 Tools Before installing the RPC 6010G rackmount workstation make sure the following tools are on hand m Philips crosshead screwdriver All the retention screws on the system are Philips screws m Soft working mat When installing the RPC 6010G rackmount workstation the screen should be placed face down on a soft working mat RPC 6010G Rackmount LCD Workstation O I RIechnology Corp 4 4 Installation Procedures 4 4 1 Preinstalled Components The following components are preinstalled in the RPC 6010G rackmount workstation m Power supply unit PSU m Cooling fan module m Drive bracket m LCD screen 4 4 2 User Installed Components The following user supplied components need to be installed into the RPC 6010G rackmount workstation m Disk drives m Backplane and CPU or motherboard m PCI or ISA expansion cards optional 4 4 3 Installation Steps Complete the following steps to properly install the workstation Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Open the top cover Remove the CPU card clamp Remove the dual CPU card clamp and drive bay stabilizer bracket Remove the disk drive bracket Install the disk drives Reinstall the disk drive bracket with the installed disk drives Install the ba
39. ightness The brightness option adjusts the brightness of screen This function adjusts the offset value of ADC Setting this value too high or too low will affect the quality of image Contrast This function adjusts the gain value of ADC Adjusting this value too high or too low will worsen the quality of image m Horizontal Size This item adjusts the screen size in the horizontal direction m Phase This option adjusts the input signal and dot clock position Analog only m H Position Adjusts the horizontal position of the display screen m Position Adjusts the vertical position of the display screen m Sharpness Adjusts the sharpness level to one of the 5 preset values This option may help reducing the softening edges around displayed objects 6 RPC 6010G Rackmount LCD Workstation 6 2 2 Color Color options are shown in Figure 6 3 Figure 6 3 Color Options The Color menu fine tunes the palette of color hues for the LCD m 9300 NTSC standard Kelvin m 7500 NTSC standard Kelvin m 6500 NTSC standard Kelvin m User This item allows fine tuning the balance among Red Green and Blue color hues if images look garish or unrealistic 2 S KT 1d 2 Corp RPC 6010G Rackmount LCD Workstation 6 2 3 Language The Languages are shown in Figure 6 4 H RE Fran ois Deutsch NACH Italiano
40. ket on the backplane To secure the PCI ISA expansion card reinsert the previously removed slot cover retention screw If necessary reinstall the CPU card clamp If necessary reinstall the dual CPU card clamp and drive bay stabilizer bracket 4 5 11 Installing Short Cards When installed some cards may still fall short below the CPU card clamp To better secure the CPU card or expansion cards use the short card clamps that came with the workstation Step 3 Step 4 Step 5 Locate the screw hole on the CPU card clamp closest to the target card Adjust the short card clamp in a vertical direction until the shock absorber part of the clamp secures the expansion card Fasten a screw to secure the card clamp 1 RIechnology Corp RPC 6010G Rackmount LCD Workstation Figure 4 15 Installing a Short Card 4 5 12 Connect the Cables The following cables may have to be connected depending on the CPU card and the backplane installed in the system m PSU cables must be connected to the following components if installed CPU card O Backplane FDD HDD O Optical drive m Disk drive ribbon cables must be connected to the corresponding CPU card disk drive connectors Other connections may have to be made please refer to the documentation that came with the CPU card lechnology Corp 4 5 13 Close Top Cover RPC 6010G Rackmount LCD Workstation
41. kmount workstation The workstation is then placed into a first internal cardboard box This box is then sealed and placed into a second external cardboard box The second box is also sealed A small box containing accessory items is placed within the internal first box 4 2 2 Unpacking Procedure To unpack the RPC 6010G rackmount workstation follow the steps below NOTE The front side LCD screen has a protective plastic cover stuck to the screen Remove the plastic cover only after the RPC 6010G rackmount workstation has been properly installed This ensures the screen is protected during the installation process Step 1 Use box cutters a knife or a sharp pair of scissors to open the top of the external second box Step 2 Open the external second box lechnology Corp Step 3 Step 4 Step 5 Step 6 Step 7 RPC 6010G Rackmount LCD Workstation Use box cutters a knife or a sharp pair of scissors to open the top of the internal first box Lift the workstation out of the boxes Remove both polystyrene ends from each side Pull the plastic cover off the workstation Make sure all the components listed in the packing list are present 4 2 3 Packing List IN NOTE If some of the components listed in the checklist below are missing please do not proceed with the installation Contact the IEI reseller or vendor you purchased the AC KIT 883HD audio module from or contac
42. model name The RPC 6010G model variations are listed in Table 1 1 Touch Expansion Model SBC Form Factor Screen Slots ACE 832AP RS ATX Power Supply RPC 6010GW ACE 832AP No Full size CPU card 14 RPC 6010GW ACE 832AP T R Yes Full size CPU card 14 RPC 6010GWATX ACE 832AP No microATX 7 RPC 6010GWATX ACE 832AP T R Yes ATX microATX 7 Page 2 Corp RPC 6010G Rackmount LCD Workstation Touch Expansion Model SBC Form Factor Screen Slots ACE R4140AP Redundant Power Supply RPC 6010GWR ACE R4140AP No Full size CPU card 14 RPC 6010GWR ACE R4140AP T R Yes Full size CPU card 14 RPC 6010GWATXR ACE R4140AP No ATX microATX 7 RPC 6010GWATXR ACE R4140AP T R Yes ATX microATX 7 Table 1 1 RPC 6010G Model Variations 1 4 Certifications All RPC 6010G rackmount workstations comply with the following international standards m RoHS For a more detailed description of this standard please refer to Appendix A O gt RJ Technology Corp RPC 6010G Rackmount LCD Workstation THIS PAGE IS INTENTIONALLY LEFT BLANK lt RIechnology Corp RPC 6010G Rackmount LCD Workstation Chapter 2 Mechanical Overview e 2 1 External Overview RPC 6010G Rackmount LCD Workstation The following sections
43. n please follow the instructions below CAUTION Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Carefully note the direction and orientation of the existing cooling fan prior to replacement Turn off and disconnect the workstation from all power sources Remove the workstation from the rack in which it is installed Open the top cover of the RPC 6010G rackmount workstation See Section 4 5 1 Remove the CPU card clamp See Section 4 5 2 Remove the dual CPU card clamp and drive bay stabilizer bracket See Section 4 5 3 Disconnect and remove all CPU cards and PCI ISA expansion cards Disconnect the cooling fan from the PSU Remove the two external retention screws that secure the cooling fan bracket to the left side panel of the workstation See Figure 5 4 4 2 RIechnology Corp RPC 6010G Rackmount LCD Workstation 7 1 gt 2 n Cmm 4 Figure 5 4 Cooling Fan Bracket External Screws Step 9 Remove the three retention screws that secure the cooling fan bracket to the bottom of the workstation See Figure 5 5 TT Figure 5 5 Cooling Fan Bracket Bottom Panel Screws e RPC 6010G Rackmount LCD Workstation Step 10 Remove the fan from the bracket by removing the four retention screws See Figure 5 6 Figure 5 6 Fan Retention Screws Step
44. ndix A Certifications RPC 6010G Rackmount LCD Workstation A 1 RoHS Compliant All RPC 6010G rackmount workstations comply with the Restriction of Hazardous Materials RoHS Directive This means that all components used to build the industrial workstations and the workstation itself are RoHS compliant The RoHS Directive bans the placing on the EU market of new electrical and electronic equipment containing more than agreed levels of lead cadmium mercury hexavalent chromium polybrominated biphenyl PBB and polybrominated diphenyl ether PBDE flame retardants RPC 6010G Rackmount LCD Workstation Appendix B Recommended IEI Backplanes Motherboards and PSUs Page 83 lechnology Corp RPC 6010G Rackmount LCD Workstation The following IEI backplanes motherboards and power supply units are recommended for the RPC 6010G rackmount workstation For more information about these backplanes please contact an IEI sales representative or visit the IEI website www ieiworld com Recommended IEI Backplanes and Motherboards The following table lists the recommended IEI backplanes and motherboards for the RPC 6010G rackmount workstation PCle PSU Model No SBC Type ISA X1 X4 X16 Connector PCI 13SD RS R30 PICMG 1 0 3 4 3 3 0 0 0 A
45. of their respective owners Page iii lechnology Corp RPC 6010G Rackmount LCD Workstation Packing List IN NOTE If any of the components listed in the checklist below are missing please do not proceed with the installation Contact the IEI reseller or vendor you purchased the RPC 6010G rackmount workstation from or contact an IEI sales representative directly To contact an IEI sales representative please send an email to sales iei com tw The items listed below should all be included in the RPC 6010G Rackmount Workstation package 1 x RPC 6010G Rackmount LCD Workstation 1 x Backplane to SBC connector cable 2 x Door keys 2 x Handles 2 x Handle brackets 1 x Mini DIN 6 PS 2 connector cable 1 x Power cable EU 1 x Screw kit 7 x Short card clamps 2 x 4 pin USB cable 1 x VGA cable For Touch Panel T R Models only 1 x RS 232 cable 1 x TouchKit Driver CD 1 x Touch Pen Images of the above items are shown in Section 4 2 3 RPC 6010G Rackmount LCD Workstation 1 RIechnology Corp Table of Contents 1 2 INTRODUCTION i isssscscessssctesccsccsnsecasetetsciccccossssedecscssecacusteedeasceseceosssccdecssssesacssssesecees 1 1 1 RPC 6010G 2 1 2 RPC 6010G 4 00000000 2 1 3 MODEL VA
46. rds see Section 4 5 10 RPC 6010G Rackmount LCD Workstation Step 7 Step 8 Step 9 Step 10 Step 11 Step 12 Step 13 O I RIechnology Corp Remove the retention screws that secure the backplane to the workstation see Section 4 5 8 Install a new backplane into the chassis Reinstall and reconnect all CPU cards see Section 4 5 9 and PCI ISA expansion cards see Section 4 5 10 Reinstall the CPU card clamp Reinstall the dual CPU card clamp and drive bay stabilizer bracket Reinstall the top cover of the workstation Reinstall the workstation into the rack Refer to Section 4 6 for complete mounting instructions 5 5 PSU Replacement To replace a PSU please follow the instructions below Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Turn off and disconnect the workstation from all power sources Remove the workstation from the rack in which it is installed Open the top cover of the RPC 6010G rackmount workstation See Section 4 5 1 Remove the CPU card clamp See Section 4 5 2 Disconnect all the PSU cables from their devices Remove the four external retention screws that secure the PSU assembly to the rear panel of the workstation Figure 5 1 RPC 6010G Rackmount LCD Workstation I T
47. rive bracket 4 5 6 Install Drives 4 5 6 1 5 25 Disk Drive The drive bracket supports three 5 25 disk drives To install a 5 25 disk drive follow the instructions below Step 1 Remove the dual CPU card clamp and drive bay stabilizer bracket from the RPC 6010G rackmount workstation see Section 4 5 3 Step 2 Remove the drive bracket from the RPC 6010G rackmount workstation see Section 4 5 4 Step 3 Remove the appropriate drive slot blank plate see Section 4 5 5 Step 4 Slide the 5 25 disk drive into the drive bracket Make sure the IDE SATA connector and the power connector of the drive are facing the rear of the bracket e RPC 6010G Rackmount LCD Workstation Step 5 Insert the appropriate number of retention screws into each side of the 5 25 disk drive through the drive bracket Figure 4 8 Figure 4 8 5 25 Disk Drive Retention Screws Other Side Similar 4 5 6 2 3 5 Disk Drive in a 5 25 Slot With the use of 3 5 to 5 25 drive bay rack a standard 3 5 disk drive can be installed into a 5 25 drive bay slot To install a 3 5 hard disk drive into a 5 25 slot of the drive bracket follow the instructions below Step 1 Slide a 3 5 disk drive into a 3 5 to 5 25 drive bay rack Make sure the IDE SATA connector and the power connectors of the drive are facing the rear of the rack Step 2 Insert the appropriate number of ret
48. stem boots or never Select if and when a four point calibration should be done Click NEXT to continue Setup Choose setup type that best suits your needs Do 4 point calibration Every system boot up C Next system boot up InstallShield lt Back Cancel Figure 7 5 Install PS 2 Interface Driver Step 9 The user is then prompted to ensure the touch monitor the USB for the touch controller is plugged into the system Figure 7 6 Once the touch controller is plugged into the system click OK IMC ij x d If you are trying to install the USB touch device please make sure that your touch monitor or touch controller s USB cable is plugged into the computer now Figure 7 6 Touch Monitor USB Touch Controller Confirmation Technology Corp RPC 6010G Rackmount LCD Workstation Step 10 The user is then prompted to select multi monitor system support Figure 6 7 Make the appropriate selection and click NEXT to continue Setup Type Choose the setup type that best suits your needs If you want to use Mulit Monitor please check the InstallShield lt Back Cancel Figure 7 7 Controller Installation Directory RPC 6010G Rackmount LCD Workstation Step 11 The user is then prompted to select a file directory in which the
49. structions below Step 1 Turn off and disconnect the workstation from all power sources Step 2 Remove the workstation from the rack in which it is installed RPC 6010G Rackmount LCD Workstation Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 Step 11 Step 12 Step 13 O I RIechnology Corp Open the top cover of the RPC 6010G rackmount workstation See Section 4 5 1 Disconnect all internal and external peripheral device connections from the CPU card Remove the CPU card clamp See Section 4 5 2 Remove the dual CPU card clamp and drive bay stabilizer bracket See Section 4 5 3 Remove the retention screw that secures the CPU card to the slot on the rear panel Slide the CPU card out of the workstation Install a new CPU card See Section 4 5 9 Reinstall the CPU card clamp Reinstall the dual CPU card clamp and drive bay stabilizer bracket Reinstall the top cover of the workstation Reinstall the workstation into the rack Refer to Section 4 6 for complete mounting instructions 5 3 PCI ISA Expansion Card Replacement To replace a PCI ISA expansion card please follow the instructions below Step 1 Step 2 Step 3 Step 4 Turn off and disconnect the workstation from all power sources Remove the workstation from the rack in which it is installed Open the top cover of the RPC 6010G rackmount workstation See Section 4 5 1 Disconne
50. t Side Similar Step 2 Remove the four retention screws that secure the dual CPU card clamp and drive bay stabilizer bracket to the fan bracket Figure 4 5 Tija Figure 4 5 Dual CPU Card Clamp and Drive Bay Stabilizer Bracket to Fan Bracket Retention Screws lechnology Corp RPC 6010G Rackmount LCD Workstation Step 3 Remove the CPU card clamp and drive bay bracket from the chassis 4 5 4 Remove the Drive Bracket The drive bracket is secured to the RPC 6010G rackmount workstation with four retention screws To remove the drive bracket please follow the steps below Step 1 Remove four retention screws that secure the drive bracket to the chassis Figure 4 4 E Me T ees 4 e 2 s Figure 4 6 Drive Bracket Retention Screws Step 2 Remove the drive bracket from the chassis 4 5 5 Remove the Drive Slot Blank Plate The drive bracket has three 5 25 and one 3 5 drive slot blank plates To remove the drive slot blank plates please follow the steps below Step 1 Remove the retention screws from each side of the drive bracket that secure the drive slot blank plates to the drive bracket Figure 4 5 RIechnology Corp RPC 6010G Rackmount LCD Workstation Figure 4 7 Drive Slot Blank Plate Retention Screws Other Side Similar Step 2 Remove the drive slot blank plate from the d
51. t an IEI sales representative directly To contact an IEI sales representative please send an email to sales iei com tw When the RPC 6010G rackmount workstation is received make sure all the components listed below are present Quantity Description Image Door key Backplane to SBC connector cable Mae 4 Handle RPC 6010G Rackmount LCD Workstation 1 RIechnology Corp Quantity Description Image g 2 Handle bracket 4 ES d 1 Mini DIN 6 PS 2 connector cable 1 Power cable 1 Screw kit 7 Short clamp ec i3 4 1 cable e 2 4 pin USB wire cable P For Touch Panel T R Models only 1 RS 232 cable C 1 Touchkit Driver CD 1 Touch pen Table 4 1 Packing List RPC 6010G Rackmount LCD Workstation 4 3 Pre installation Preparation 4 3 1 System Planning User supplied CPU cards and backplanes or motherboards need to be installed in the system before installing the RPC 6010G rackmount workstation The backplane determines the following system parameters m CPU card type m The CPU card determines the following system parameters m CPU m Embedded graphics m System memory m and optical drive connectivity and capacity m Speed It is therefore proper to correctly spec
52. workstation To rack mount the workstation please follow the steps below Step 1 The left and right side panels of the workstation each have four screw holes for rack handle bracket installation Assemble the rack handle brackets and secure them to the workstation See Figure 4 16 Figure 4 16 Rack Handle Bracket Assembly and Installation I Technology Corp RPC 6010G Rackmount LCD Workstation Step 2 Remove the rack slides from the rack slide brackets See Figure 4 17 Figure 4 17 Remove Rack Slide Step 3 The left and right side panels of the workstation each have five screw holes for rack slides Attach one slide section each to the left and right side panel of the workstation See Figure 4 16 OT 6 1 RIechnology Corp RPC 6010G Rackmount LCD Workstation Figure 4 18 Workstation Slide Installation Other Side Similar Step 4 Assemble the slide brackets per the manufacturer s instructions See Figure 4 19 I Technology Corp Figure 4 19 Rack Slide Bracket Assembly Step 5 Attach the slide brackets to the rack per the manufacturer s instructions See Figure 4 20 1 RIechnology Corp RPC 6010G Rackmount LCD Workstation 107 207 Figure 4 20 Rack Slide Bracket Installation Step 6 Insert the workstation with the attached slides into the rack slide brackets until the h
53. y Corp RPC 6010G Rackmount LCD Workstation PS 2 VGA Optional Touch Screen PSU Expansion Slot Typ Figure 2 3 RPC 6010G 14 Slot Rear Panel 2 1 2 2 ATX Motherboard Rear Panel The RPC 6010G rackmount workstation is available with two types of rear panel brackets The ATX motherboard rear panel has the following rear panel items m Internal PSU m 7 expansion slots connector m PS 2 mouse connector m Optional Touch Screen connector m Motherboard connector area mme I RIechnology Corp PS 2 VGA Optional Mouse Touch Screen RPC 6010G Rackmount LCD Workstation 00L1fdNI OW PSU ATX Expansion Slot Motheroard Figure 2 4 RPC 6010G ATX Motherboard Rear Panel 2 1 3 Right Side Panel The RPC 6010G rackmount workstation has the following right side panel items m Cooling vents Cooling Vents Figure 2 5 RPC 6010G Right Side Panel lechnology Corp RPC 6010G Rackmount LCD Workstation 2 1 4 Left Side Panel The RPC 6010G rackmount workstation has the following left side panel items m Cooling vents Cooling Vents Figure 2 6 RPC 6010G Left Side Panel 2 2 Physical Dimensions The following sections describe th

Download Pdf Manuals

image

Related Search

Related Contents

Bedienungsanleitung  Bedienungsanleitung - WilTec Wildanger Technik  Philips 7000 series BDP7500S2  DVIGear: DVI-7315 / User Guide r2  USER MANUAL - Wolf Laboratories  Samsung Màn hình LED 19" với chất lượng hình ảnh sắc nét Hướng dẫn sử dụng  CATA 02197410 cooker hood  製品マニュアル  SEED-DEC138  

Copyright © All rights reserved.
Failed to retrieve file