Instrukcja Prolift EN.cdr
Contents
1. Electric projector lift Avers Prolift User s manual Read these instructions carefully before operating the screen N Dear Customer Thank you very much for the purchase of our product The manual booklet contains all operation information you may require to install properly and operate the lift We hope it will help you to get the most performance and enjoyment of your new projector lift Enjoy time with the Avers Screens product SAFETY INFORMATION NOTICE Important safety information Follow the instructions described in the operating manual for safety reasons After reading the manual please store it in a safe place just in case you need it in the future NOTICE THE DEVICE HAVE TO BE EARTHED WARNING 1 Disconnect the device from the power supply if it will not be used within longer period of time 2 Do not open the casing of the device in order to avoid possible electric shock There are not any user operated parts inside the case of the screen All service work can be done by Avers Authorized Service Center personnel only 3 Do not remove the Ground pin from the power outlet neither connect the device to the socket without the Ground pin If you can t put the plug to the power outlet please ask electrician for assistance Table of contents 1 Safety rules 1 1 Declaration of Conformity CE 2 Product specification 2 1 Contents of package 2 2 Technical data 3 Lift installa
2. Diameter of the anchors used to fix the lift mechanism to the ceiling should be 8 mm or more Fix the projector universal installation bracket to the horizontal lift arm Check and correct if needed levelling of the projector installed at the lift arm Check and correct if needed if the roll installed at the bottom of the lift column is located at the same side as the Prolift flap hinges are located The roll must be fixed at the position so it will roll without any problems along the line perpendicular to the edge of the flap with the hinges In case the optional Prolift Flap will not be used to mask the hole in the false ceiling it is possible to fix part of the false ceiling to the bottom of the lift column If so the roll located at the bottom of the lift column must be deinstalled before Total weight of the installed projector and part of the false ceiling fixed to the bottom of the column should not exeed 15kg In case the false ceiling has segmented design with metallic profiles the potential locations of the lift installation place are determnied by the false ceiling construction The lift must be installed over the single false ceiling tile located in front of the screen at the distance similar to the required projection distance We recomend to install the optional Prolift Flap instead the false ceiling tile located below The part of the false ceiling tile can be placed in the moving part of the flap so it will not differ
3. Check carefully after lift installation and before first operation nor the lift elements nor the installed projector will not collide with the recessed ceiling hole during lift operation 3 2 Lift installation at the ceiling Define location of the hole in the recessed ceiling Projector installed at the lift will be ejected through during projection Dimensions of the hole must follow the dimensions of the installed projector and or the dimensions of the flap mechanism Distance between the screen and the hole is determined by the planned projection distance see picture 1 oe D Projection distance S Picture width Pic 1 Mapping out location of the lift phase 1 Fix the projector to the lifts universal bracket use screws supplied with the lift Decide the point universal bracket will be fixed to the lift column arm see picture 2 Measure distance between the lens optical axis and the lift column see picture 3 o000 000 Q 000 8000 Q Q GOOD GOOD WRONG Pic 2 Recommended projector installationmethod II CAUTION Projector should be installed at the lift arm so the projector lens will be located as clos to the lift column as possible most important in case of projectors with non central lens design Pic 3 Lens optical axis to Lift column distance measure Determine final location of the lift hole at the false ceiling Shifting of the hole positi
4. 60 months 3 Surety commits to fix free of charge any failures component or production defects of the product which appear during warranty period 4 Warranty exclusions a the failures caused by the usage of the lift against the rules described in operation manual b the failures caused by improper storage or transportation c mechanical defects of the lift other than mentioned at point 3 d damages caused with overvoltage at power network e deinstallation and reinstallation of the lift 5 Avers Screens Service department will remove all defects within 21 days after receiving the demaged product 6 Warranty claims should be passed to the lift supplier dealer Appendix Prolift mechanism installation plate Dimensions and location of installation holes All dimensions are in metric standard 170 12 73 200 Manufactured after 13 08 2005 This symbol on the products and or accompanying documents means that used electrical and electronic products should not be mixed with general household waste Disposing of this product correctly will help to save valuable resources and prevent any potentialnegative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point
5. Operation of the lift with damaged power cord can result with electric shock electric short circuit and fire e Do not touch the power cable wall switch nor the power plug with wet hands e Always follow the instructions described in the operating manual 1 1 Declaration of Conformity CE AVERS SCREENS Manufacturer s Declaration of ConformityCE AVERS Screens Sp z 0 0 Under it s own responsibility declares All screensand accessories mentioned below are manufactured in Polandaccording to the essential safety requirements of Council Directive 98 79 WE Projection screens Stratus AkuStratus Focus Cumulus X Solar Solaris Contour Altus Cirrus CL Cirrus X Cirrus X crank Projector mount brackets Alumount Promount SimpleMount Prolift The above mentioned products are in conformity with the European Directives and especially with the norms PN EN 55014 1 2007 U PN EN 50082 1 1997 PN EN 60335 1 2004 PN EN 61000 3 2 2007 PN EN 61000 3 3 1997 C IEC 60335 2 97 2007 2 Product specification Electrically operated projector lift designed for fixed installation at projection systems for business presentations and or home cinema applications Allows hidden projector installation in rooms with recessed false ceiling Available in three versions with different operating ranges Compatible with dedicated self closing masking ceiling flap model Avers Prolift Flap
6. and remote control systems for comfortable operation 2 1 Contents of packaging Please check carefully if any physical damage of the screen has not happened during transportation Please inspect the package for all accessories presented below M4x40 x2 comma M8x30 x1 M5x35 x2 wml M4x35 x2 a x1 M5x40 x2 do Lift x 1 Installation accessories Installation accessories Installation accessories Regulation wrench x 1 Wall switch x 1 Operation manual x 1 2 2 Technical Data Dimensions of projector lifts Total height Lift dimensions Covered range of Lift Model Operating range mm Lift in upper excl projector projector fixing position mm bracket mm wholes mm Prolift 300 300 325 Prolift 400 400 425 500 x 407 200 400 Prolift 500 500 525 Projector weight up to 15 kg Engine Electric tubular engine Voltage 220 240V AC 50 Hz 125 W Power consumption 0 52A Rotation speed 28 rot min Torque 3Nm max operation time 4 min Engine single cycle operation time operation cycle can be repeated in 20 minutes intervals 3 Lift installation 3 1 Installation precautions Installation work should be carried out by a qualified technician in accordance with the instructions described below Fixed installation of the lift should be done with use of the screws and anchors suitable for the ceiling s construction materials at the installation place
7. if so the rope would tangle and the lift will be blocked 4 Lift operation Projector lift AVERS Prolift can be operated manually or automatically if the additional Avers or 3 rd party control system will be installed 4 1 Manual operation Manual lift operation is possible with the wall control switch Push button v the lift will begin to move down and stop automatically at the bottom stop position Push button 4 the lift will begin to move up and stop automatically at the upper stop position 4 2 Lift maintenence Pojector lift Avers Prolift do not require periodical service maintenance Clean dust from the lift with dry soft cloths If needed use moisturized cloth with soft detergent to remove stains After stain removal dry the cleaned surface with cloth carefully 4 3 Before calling the service Symptoms Reasons Remedy The lift does not operate Power failure Check the lift s circuit fuse and the power up down cable The lift stops operation in the The lift steel control rope is blocked Unlock the bocked rope Check the proper middle position lift programing Power failure Check the propriety of electric installation and the state of the power wires At other cases please contact service 5 Warranty conditions 1 Avers Screens warranty period is 24 months from the date of purchase confirmed with the original purchase invoice 2 Extended warranty period for electric engine is
8. on to the left or right side would be required depending on the design of installed projector The lift hole localization at the false ceiling must provide that the installed projector lense optical axis will be perpendicular to the screen surface and will cross the screen at the middle of screen width see picture 4 A Lift hole location Phase1 Phase 2 Screen Axis Lens Optical Axis BS Prolift Flap A B 59 5cm D AB L 1 cm a Lift hole location Phase1 Phase 2 Screen Axis Lens Optical Axis BS Prolift Flap A B 59 5cm Dicm L m Pic 4 Mapping out location of the lift phase 1 Cut off the hole in the false ceiling Appoint the location of holes for the anchors used to fix the lift mechanism to the real ceiling Lift must be fixed at the right position The optical axis of the projector installed at the lift must be perpendicular to the screen surface and must cross the screen in the middle of it s width In case the optional Prolift Flap will be used during lift installation to mask the hole in the false ceiling we recommend that the front side of the projector installed with the lift will move as close to the front edge of flap as possible Fix the lift mechanism with the installation anchors I I CAUTION
9. tion 3 1 Installation directions 3 2 Lift installation at the ceiling 3 3 Electric installation 3 4 Programming 4 Lift operation 4 1 Manual operation 4 2 Before asking for service 5 Warranty conditions 1 SAFETY RULES SAFETY INFORMATION NOTICE Important safety information It is important for the safety of persons to follow these instructions After reading the manual please save it just in case of need in the future e Do not allow children to play with the fixed controls remote control e Keep the remote control unit out of reach of children e Frequently examine the lift installation for imbalance and signs of wear or damage to cables Do not use if repair or adjustment is necessary e Watch the moving lift and keep the people away until the lift is completely rolled in out It will help to avoid injuries caused with moving screen e Do not attach any objects to the lifts column Lift damage and or person injury danger e All installation work should be carried out by the qualified technician e Improper installation of the lift can cause device damage or health breakdown Do not do anything that may damage the power cable or power plug e Do not damage the power cable The following operations with the power cable are not allowed making any modifications by your own puting it near the hot objects bending it strongly twisting it pulling it out putting the heavy objects on it wrapping it into the bundle e
10. uring the lift operation c wall switch operator cannot stay in reach of any of the lifts moving parts during the lift operation d the wall switch must be visible from the each part of the room irrespective of the lift position 3 5 Lift programming Avoid lift programming without important reason The lift upper and bottom stop points were set at the factory to cover the maximum lift operating range The lift must be re programmed if you intend to lower the upper stop point or upgrade the bottom stop point Programming of the lift bottom stop position Programming knob 2 red allows programming of the lift bottom stop position t turn the knob this direction to lower the lift bottom stop position the lift is programmed at the factory at the lowest possible bottom stop position turn the knob this direction to move up lifts bottom position Programming of the lift upper stop position Programming knob 1 white allows programming of the lift bottom stop position turn the knob this direction to lower the lift upper stop position turn the knob this direction to move up lifts upper position the lift is programmed at the factory at the highest possible upper stop position Avoid to overstress the lift steel rope during when programming the lift upper stop position it could cause the lift damage Avoid to leave the lift steel rope slack after programming of the lift bottom stop position
11. with the other tiles of the false ceiling Projection screen should be installed at the position determined by the lift installation place to provide best possible picture quality I I ATTENTION Space between the false ceiling and real ceiling must be kept clean and tidy to guarantee long term and reliable operation of the projector installed at the lift Dust and remains of the construction work must be removed from there before the projector installation and operation 3 4 Electric installation Caution Electric installation of the lift should be performed by an authorized electrician Lead out the power cables to the place of installation of the wall switch and between wall switch and lift Lift power line should be fused with 1A fuse Switch off the lift power line during installation work Lift bl blue common br brown up direction yg yellow green protective bk black down direction F 30 br LIE Power line L1 brown live G L N blue neutral G yellow green protective 1 2 230 V Picture 9 Lift electric installation Picture10 Lift Programming Manual wall steering switch should be installed at the place meeting the following conditions a installation150 180 cm above the floor level b the lift should be visible by the wall switch operator d
Download Pdf Manuals
Related Search
Related Contents
Garmin 190-00864-01 User's Manual Trust Digital TV & Radio Samsung Blu-Ray BD-E5300 Manual de Usuario Yaesu FL-2100Z user manual Guida dell`utente per i sistemi Polycom HDX CL-1500 Copy Lathe Panas。m。 取扱説明書 保管用 acculaders ladegeräte battery chargers Manuel d`installation PDF ESC Datalog Manual - BMI Copyright © All rights reserved.