Contents
1. 2 std and 2 none std 36 mm mushroom 2 1001 478 Printer paper 1 roll MOV applies 4 rolls supplied if printer configured 25995 001 UK UNITED STATES OTHER TECHNICAL SALES OFFICES CERTIFICATION ISO Archcliffe Road Dover 4271 Bronze Way Valley Forge USA College Station USA Registered to ISO 9001 2000 Cert no Q 09290 CT17 9EN England Dallas TX 75237 1019 USA Sydney AUSTRALIA T by SWEDEN Ontario Registered to ISO 14001 1996 Cert no EMS 61597 T 44 0 1304 502101 T 800 723 2861 USA only CANADA Trappes FRANCE Oberursel F 44 0 1304 207342 T 1 214 333 3201 GERMANY Aargau SWITZERLAND Kingdom OTS80PB_OTS60PB_DS_EN_V01 UKsales megger com F 1 214 331 7399 of BAHRAIN Mumbai INDIA Johannesburg www megger com USsales megger com SOUTH AFRICA Chonburi THAILAND Megger is a registered trademark
2. power lead NiMH battery IEC electrode set internal printer lid stirrer and carry bag mode ots PBs b b 80 kV Select Model 60 kV Se EU Lead UK Lead Select V Power i Cord US Lead Australian p Di Lead Sealed Lead Acid OPB Select Battery 0 8 kg Option Select Electrode m Internal Printer Printer Option IN 0 08 kg Stirrer Lid Select Assembly Stirrer Fitted Option Stirrer Lid Assembly Not Fitted Carry Case Option gt lt No Carry X Case Vi eg g er OTS80PB OTS60PB Portable oil test sets ORDERING INFORMATION Product Order Code Product Order Code Included Accessories Full electrode set ASTM and IEC electrodes 1001 479 Vessel 400 ml assembly Vessel lid mounted impeller ASTM D1816 for use 12 V vehicle charger lead supplied only on instruments with 400 ml vessel 1001 102 configured with a battery Carry bag padded OTS80PB 1001 476 Magnetic bead stirrers 2 off Carry bag padded OTS60PB 1001 480 Magnetic bead retriever Optional accessories Feeler gauge set 1 2 2 5 2 54 mm Transport case with wheels 1001 475 User manual Vessel 400 ml assembly Configured accessories to order additional or spares no electrodes supplied 1001 473 IEC60156 Electrode Set 12 7 mm spherical 2 Vessel 150 ml assembly 36 mm mushroom 2 1001 477 no electrodes supplied 1001 474 ASTM D877 1816 electrode set 25 4 mm cylindrical VCMD Digital calibration meter 1001 105
3. Megger OTS80PB OTSGOPB Portable oil test sets OTS80PB and OTS60PB Portable oil test sets DESCRIPTION Megger s automatic portable oil test sets perform accurate breakdown voltage tests on mineral ester and silicon insulating liquids Moulded test vessels give repeatable results in the field and laboratory with lock in precision electrode gap set ting adjustment wheels The transparent shielded lid is a key feature enabling users to see what is happening within the test chamber Megger portable 60 kV and 80 kV oil test sets are the lightest on the market ranging from 16 kg to 23 5 kg depending on model and configuration They come complete with optional carry bag and transport case The carry bag has pouches for electrode accessory pack leads quick user guide paper roll etc The units are mains powered with optional lead acid or NiMH batteries In addition an internal 12 V DC charger and vehicle adaptor cable is standard with either battery option Test standards are preloaded in the instrument and new versions can be uploaded via USB flash drive Both portable instruments support the creation of user defined custom tests Test results are identified either by a serial number or asset ID and are time and date stamped An optional internal printer provides a hard copy of results Ink based printout ensures durability at all temperatures USB interfaces x3 support PC connection USB flash drive external USB print
4. NAL ITEMS m Factory fitted lead acid OTS80PB only or NiMH battery with 12 V charger and vehicle lead m Internal printer Motorised lid impeller m Voltage check unit VWCM100D m Carry bag m Iransport case APPLICATION Monitoring and maintenance of oil quality is essential in ensuring the reliable operation of oil filled electrical equipment Codes of practice have been established in many countries that include several different types of test on insulating oils One of the fundamental tests of oil quality is the breakdown voltage test which is a measure of the oil s ability to with stand electric stress A low breakdown voltage can indicate the presence of contaminants such as water or conducting particles Megger Care should be taken to ensure the process of sampling oil and subsequent testing does not in any way contaminate it with foreign objects Cleaning vessels between oil tests should be a rinse with the next sample never clean with fibrous materials To ensure an accurate reading set gap carefully and lock adjusting wheels SPECIFICATIONS Test voltage OTS 60PB OTS 80PB Voltage resolution Programmed test sequences 30 to 30 kVrms 40 to 40 kVrms 0 1 kV 1 2 digits ASTM D 1816 04 ASTM D 8774 02 ASTM D 877B 02 IEC 60156 95 Vessels 400 ml standard 150 ml option Nylon 12 chamber provides precision electrode alignment and adjustment wheels lock electrodes in position
5. er and barcode scanner User safety is paramount and Megger have designed independent and dual redundant high voltage cut off circuitry to ensure safety During a test the operator can terminate by pressing any button on the keyboard which will remove high voltage immediately and abort the test The transparent lid provides ample visibility within the chamber yet is protected and electrically shielded by a screen with E Light weight rugged portable instruments for measuring insulating oil breakdown voltage Lock in precision oil vessel with lockable adjustment Bright 3 5 inch colour display visable out doors Suitable for mineral ester and silicon oils Trip detection circuit with direct measure ment of voltage and current Ultra fast lt 10 us HV switch off time multiple links to instrument ground FEATURES AND BENEFITS m Test voltages up to 60 kV or 80 kV m Lock in precision oil vessel lockable gap setting m Flat electrode gap gauges that will not damage electrodes m Automatic oil temperature measurement m QVGA colour display with backlight m Easy clean chamber with oil drain m Safe operation with dual redundant micro switch HV cut off zero volt touch bar and screened lid m Transparent lid results in highly visable test chamber and vessel m Intuitive user interface supports fully automatic operation with preloaded international test standards plus user configurable test sequences OPTIO
6. option of 150 ml vessel for low volume oil samples Temperature sensor resolution Power supply Batteries option Interfaces Internal Printer option External printer Protection Display Dimensions OTS 60PB OTS 80PB Weight OTS 60PB OTS 80PB Test vessels Environmental Operating temperature Storage temperature LG Line voltage 85 to 265 VAC Line frequency 50 60 Hz Lead acid 2x 12 V4 Ah or NiMH 24 V 2 Ah USB 2 0 compatible 2 x USB type A memory stick 1 x USB type B printer or PC Matrix impact printer Paper 57 5 mm wide Any printer with USB interface and PCL3 driver Safety interlock on cover 320 x 240 QVGA colour display with backlight 520 mm x 340 mm x 250 mm 520 mm x 380 mm x 250 mm 16 kg printer no battery 16 8 kg printer NiMH battery 20 kg printer no battery 20 8 kg printer NiMH battery 23 2 kg printer lead acid batteries 1 1 kg 400 ml and 150 ml 0 C to 50 C 30 C to 65 C OTSSOPB OTS60PB Portable oil test sets Humidity 80 RH at 40 C operation 95 RH at 40 C storage Safety Designed in accordance with IEC61010 EMC Light industrial IEC 61326 1 Class B CISPR 22 CISPR 16 1 and CISPR 16 2 VCM100D 400 ml vessel assembly electrodes fitted Vi eg g er OTSSOPB OTS60PB Portable oil test sets ORDERING CONFIGURATION Example of an ordering configuration OTS80PB EU2 EP 4C This order is for an OTS80PB with EU