Home
Data Sheet - Valiant Communications Limited
Contents
1. Framing Transparent PCM30 and PCM31 Bit Rate 2048 Kbps 50 ppm Line Code HDB3 Nominal Impedance 120 Ohms balanced Peak Voltage of a mark 3 0V 0 3V For 120 Balanced interface Peak Voltage of a space OV 0 3V For 120 Balanced interface Nominal Pulse Width 244 ns Pulse Mask As per ITU CCITT Rec G 703 Output Jitter lt 0 05 UI in the frequency range of 20Hz to 100 Khz Permissible Attenuation 6 dB at 1 Mhz Return Loss at 51 2 KHz to 102 4 KHz 102 4 KHz to 2048 KHz 2048 KHz to 3072 KHz gt 12dB gt 18dB gt 14dB Jitter Tolerance As per ITU CCITT G 823 Connectors 64 x RJ 45 F connectors 19 Inch 3U shelf version Connectors 64 Port 8 x DB37 F connectors 19 Inch 2U shelf version System Management and Access e Windows XP and Windows 7 compatible Graphical User Interface GUI e Telnet CLI Command Line Interface SNMP V2 MIB File provided with the equipment Managementand Control Port e Serial Management Port RS232 COM Port USB Serial Port 10 100BaseT for remote management over a LAN TCP IP network Command Language e Command Line Interface english text commands Copyright Valiant Communications Limited 5 Management VCL XC 64 E1 Electronic Patch Panel Network interface RJ 45 Ethernet 10BaseT or 100BaseTx auto sensing MDI X Compatibility Ethernet Version 2 0 IEEE802 3 Protocols supported ARP UDP IP T
2. 64 E1 Electronic Patch Panel can easily be integrated into any standard existing customer s NMS An MIB file is provided with the equipment for easy integration Copyright Valiant Communications Limited 2 VCL XC 64 E1 Electronic Patch Panel An Intelligent Patch Panel VCL XC 64 Port E1 Electronic Patch Panel keeps the user informed of potential problems by generating SNMP V2 alarms VCL XC 64 Port E1 Electronic Patch Panel generates SNMP V2 alarms and is supplied with an MIB file which allows the user to easily integrate the VCL XC 64 Port E1 Electronic Patch Panel into their NMS Network Management Software for faster trouble shooting and fault rectification This results in more efficient network control and fault management VCL XC 64 Port E1 Electronic Patch Panel also maintains a log of the 200 most recent time stamped events as they occur in real time by storing them in the system memory These events may be viewed at any time by a user The system event log is maintained in addition to SNMP V2 traps which the equipment sends out to a centralized NMS when such events or alarms occur User friendly the equipment may be assessed remotely using Telnet GUI Graphical User Interface or SNMP over an Ethernet link through the system s 10 100BaseT Ethernet Port The equipment may be also accessed locally through either an RS232 DB9 serial ora USB COM Port Highlights e 64circuit E1 to E1 electronic remotely manageable pat
3. Converter Panel 19 Metal case 1U High Rack Mount Version Includes DB37M DB37M Cables BNC cables not included Technical specifications are subject to changes without notice Revision 12 March 10 2015 U K Valiant Communications UK Ltd 1 Acton Hill Mews 310 328 Uxbridge Road London W3 9QN United Kingdom E mail go gt valiantcom com U S A INDIA Valcomm Technologies Inc Valiant Communications Limited 4000 Ponce de Leon Suite 470 Coral Gables FL 33146 U S A E mail us valiantcom com Copyright Valiant Communications Limited 71 1 Shivaji Marg New Delhi 110015 India E mail mail valiantcom com
4. systems NMS or for easy integration with standard SNMP browsers Where itshould be used who should use itand in which applications VCL XC 64 E1 Electronic Patch Panel is designed to be used in Central Offices Data Centers Command and Control Centers Remote Cell Sites Utilities and Dealing Rooms seeking to eliminate the jungle of external patch cords and loosely hanging wires which usually exists in locations where E1 patch panels are installed Why itshould be used VCL XC 64 E1 Electronic Patch Panel eliminates the use of patch cords and the maze of loosely hanging inter connect wires Easier Management VCL XC 64 E1 Electronic Patch Panel allows easier management of the E1 cross connects since all cross connects can be made and managed from a central location over TCP IP or UDP Network using either CLI text commands or a GUI Efficient Management VCL XC 64 E1 Electronic Patch Panel allows a more efficient management since a log database of all circuit patches cross connects can be saved and archived as a MS Microsoft Access database file and retrieved and re loaded whenever required VCL XC 64 E1 Electronic Patch Panel eliminates the need for labeling the patch cords and inter connected wires since all inter connection records are automatically retained in the system s non volatile memory Additionally the same can also be saved and archived as a MS Microsoft Access database file from the system s GUI VCL XC
5. CP IP Telnet ICMP SNMP LEDs 10Base T and 100Base TX Activity Full half duplex Management SNMP Serial login Telnet login EMI Compliance Radiated and conducted emissions complies with Class B limits of EN55022 1998 Direct and Indirect ESD complies with EN55024 1998 RF Electromagnetic Field Immunity complies with EN55024 1998 Electrical Fast Transient Burst Immunity complies with EN55024 1998 Power Frequency Magnetic Field Immunity complies with EN55024 1998 RF Common Mode Conducted Susceptibility complies with EN55024 1998 Power Supply Specifications Input DC Voltage 48V DC nominal Range of Input Voltage 18V DC to 72V DC Input Voltage Reversal Protection Protected Over Current Protection 3 Amperes Short Circuit Protection Current limit up to 3 Amperes recovers on removal of short circuit Efficiency at Full Load gt 93 Ripple at Full Load lt 5mVrms Spike at Full Load lt 50mV Power Supply Power supply 48V DC 18V DC to 72V DC Power supply Redundant 1 1 Protected Inputs Power consumption 14 watts maximum Environmental Temperature and Humidity 0 C to 50 C 90 R H Non condensing Altitude Upto 9 000 feet Compliance e FCCPart68 Class B e CE Copyright Valiant Communications Limited Chassis e Option 1 3U high rack mount
6. able RJ 45 F 19 inch shelf e Option 2 2U high rack mountable DB 37 F 19 inch shelf VCL XC 64 E1 Electronic Patch Panel Dimensions Particulars 3U high rack mountable 2U high rack mountable RJ 45 F 19 inch shelf DB 37 F 19 inch shelf Depth 292 mm 260 mm Width 485 mm 485 mm Height 3U 133 33 mm 2U 90 mm Ordering Information S No PartNo Product Description 1 VCL XC 1466_1467 ELE E1 120 RJ45F 64 VCL XC 64 E1 Electronic Patch Panel VCL XC 64 Port 64xRJ45F Electronic Intelligent Patch Panel E1 to E1 19 Shelf 3U High Rack Mount Version Supports 64 x E1 interface 120 Ohms 64 x RJ45 F Connectors 2 x 48V DC Power Supply Input 1 x System Core Cables Installation Accessories Documentation System User Manual Disk etc OAM SNMP Telnet RJ45 Port and Serial Port USB and DB 9 COM port 2 VCL XC 1466_1468 ELE E1 120 DB37F 64 VCL XC 64 E1 Electronic Patch Panel VCL XC 64 Port 08xDB37F Electronic Intelligent Patch Panel E1 to E1 19 Shelf 2U High Rack Mount Version Supports 64 x E1 interface 120 Ohms 8 x DB37 F Connectors 2 x 48V DC Input Power Supply 1 x System Core Cables Installation Accessories Documentation System User Manual Disk etc OAM SNMP Telnet RJ45 Port and Serial Port USB and DB 9 COM port 3 VCL 1514 1513 CON 120 DB37F 75 BNCF 16 16 x E1 120 2xDB37F to 75 82xBNCF
7. ch panel Allows the user to cross connect between any E1 portto any E1 port or any E1 port to Multiple E1 Ports ina broadcast mode only electronically Eliminates the use of the messy loose hanging inter connect wires Host of alarms for trouble shooting and maintenance SNMP V2 Traps Alarms Telnet and GUI based remote management features Dual power inputs 1 1 to connect the equipment to two separate 48V DC power sources for power source redundancy e Compact Available in 19 inch 2U shelf DB37 connector version and a 19 inch 3U shelf RJ45 connector version Indications and Alarm Monitoring Loss of incoming signal at any E1 Port Configuration error alarm 64 LED indicators to indicate the status of each E1 link System s internal 3 Volts power supply present External 48V DC input present System Self Test Error Programmable Features e Enabling or disabling E1 channels masking alarms of the E1 channels that are un connected and not in use e Creating across connect between E1s using the Windows based easy to use GUI e _Telnetinterface for remote programming by using text commands Copyright Valiant Communications Limited 3 VCL XC 64 E1 Electronic Patch Panel Status Monitoring Status of alarms Enabled Disabled status of E1 ports Monitoring of the VCL XC 64 Port E1 Electronic Patch Panel status and configuration SNMP V2 Traps Alarms Dual Power Inputs e The system provides dual 48V DC
8. oe Val LIANT Poe COMMUNICATIONS Sh OMI Ka ALTTO s eeqee VCL XC 64 Port Electronic Intelligent Patch Panel El to El Patch Panel Product Brochure amp Data Sheet U K Valiant Communications UK Ltd 1 Acton Hill Mews 310 328 Uxbridge Road London W3 9QN United Kingdom E mail go gt valiantcom com U S A Valcomm Technologies Inc 4000 Ponce de Leon Suite 470 Coral Gables FL 33146 U S A E mail us valiantcom com INDIA Valiant Communications Limited 71 1 Shivaji Marg New Delhi 110015 India E mail mail valiantcom com VCL XC 64 E1 Electronic Patch Panel Product Description The VCL XC 64 E1 Electronic Patch Panel allows the user to cross connect any E1 port to any E1 port electronically through user executable software commands without having to use any patch cords or loosely hanging inter connect cables VCL XC 64 E1 Electronic Patch Panel also provides the user with the capability to uni directionally broadcast a E1 input to multiple E1 destinations The patch panel may be accessed remotely over a TCP IP link using Telnet This allows the user to create patch new circuits remotely and make new E1 cross connections on the fly SNMP V2 Traps are also generated over a UDP link which allows the user to monitor the patch panel and all E1 circuits remotely for any alarms An MIB file is provided with the patch panel to allow easy integration with customer s network management
9. power inputs for connecting the equipment to two separate 48V DC power sources for added security and power backup Rear View Option 1 with 3U high rack mountable RJ 45 F 19 inch shelf 22 21 20 19 18 160 15 14 13 5 i E OE E E Ce O kJ P22 P21 P20 P19 P18 P16 P15 P14 P13 P5 44 43 4244 1 40 3 36 35 2 OOOOOOOCD P44 P43 P42 P41 P40 P38 P37 P36 P27 64 63 62 6 1 60 59 58 49 ee ae e O Ld P64 P63 P62 P61 P60 P59 P58 NO COM NC ALARM E1 PORT Copyright Valiant Communications Limited 4 VCL XC 64 E1 Electronic Patch Panel Technical Specifications E1 Interface Maximum Number of Interfaces 64 E1 Interfaces Conformity Electrical ITU T G 703