1. AF 92 HEATER MODULE AF 93 CHEMICAL FILTER MODEL AF 92 HEATER MODULE HEATER INSTALLATION 1 Remove coupling from heater cap 2 If 1 diameter heater is to be used remove smaller rubber gasket if 34 diameter heater is used use both gaskets small inside the large Slide coupling over heater tube Insert heater through gasket and clear cap Screw on coupling to clear cap and tighten Screw clear cap with heater installed onto heater module HAND TIGHTEN ONLY Start water flow through module Turn on heater and adjust oO oR OW CON CAUTION AT NO TIME OPERATE HEATER WITHOUT MODULE FULL OF WATER DAMAGE WILL RESULT TO BOTH HEATER AND HEATER MODULE IF HEATER IS OPERATED WHEN DRY DO NOT LUBRICATE GASKETS MODEL AF 93 CHEMICAL FILTER HOW TO CHARGE THE CHEMICAL CHAMBER 1 Unscrew module cap 2 Remove cup spring and cartridge plug 3 Remove chamber from module 4 Fill chamber with coarse granular carbon or other media that will not pass through the chamber screen Rinse carbon by letting water run down chamber through open end until clear 6 Install chamber in filter module Make sure chamber fits onto center hub in bottom of filter module Chamber should protrude about As above module Replace cartridge plug Install cup spring large end over cartridge plug Before replacing module cap make sure O ring is clean lubricated with Lifegard Silicone and is in place HAND TIGHTEN ONLY
2. O1 O CO N HOW TO CLEAN AND RECHARGE Shut off pump Shut off inlet and outlet valve installed below the level of the module cap Remove cap from module Remove cup spring cartridge plug and chamber from module Empty carbon or other media from chamber Fill chamber with new carbon or other media Make sure filtering media will not pass through the chamber screen Rinse carbon by letting water run down chamber through open end until clear 8 Before replacing module cap remove the O ring and thoroughly clean it and lubricate the O ring with Lifegard silicone and replace cap on the module and HAND TIGHTEN ONLY 9 Open inlet and outlet valve and start pump OouahkAND N REDUCER BUSHINGS AF Modular Series units have option of connection to 3 4 MPT or 1 MPT using reducer bushings included in package 11 4 x 3 4 1 x 1 1 x 3 4 or 11 2 x 1 Bushing of your choice should be glued using a PVC ABS compatible glue R174000 11 4 x 3 4 Lifegard Reducer Bushing R174001 11 4 x 1 Lifegard Reducer Bushing R174002 1 4 x 3 4 Lifegard Reducer Bushing R174003 1 4 x 1 Lifegard Reducer Bushing DOO AF 94 MECHANICAL FILTER HEATER R175022 COUPLING aoe Ys FOR COUPLING e R175023 GASKET FOR COUPLING R175021 3 CLEAR HEATER CAP W COUPLING CD 220001 CAP O RING p R270313 34 CLOSE NIPPLE R270484 1 CLOSE NIPPLE R172008 3 FILT
3. www lifegardaquatics com R172045B PRESSURE GAUGE R172045A GAUGE ADAPTER amp AIR BLEED R172012 3 CAP WITH 14 HOLE 220001 CAP O RING R172014 CARTRIDGE PLUG R172043 CUP SPRING R175028 PLEAT RETAINER R175024 COMBINATION CARTRIDGE COMPLETE SEE BELOW FOR MODELS AE 94 19 AND AF 94 29 R175026 PLEAT ONLY STANDARD R175028 PLEAT RETAINER Model AF 94 19 and AF 94 29 do not use the combination cartridge When cleaning remove center stand pipe clean and replace refer to drawing R270313 34 CLOSE NIPPLE R270484 1 CLOSE NIPPLE MODELS AF 94 19 AF 94 29 ONLY R175025 AQUARIUM CARTRIDGE COMPLETE HAS NO CARBON RETAINER AF 94 19 2 REQUIRED AF 94 29 3 REQUIRED PLEATS ARE SAME AS MODULE AF 94 CENTER STAND PIPE R172018 FOR AF 94 19 R172017 FOR AF 94 29 COMPLETE MODULAR To SYSTEM Aquarium Mechanical Chemical Heater Ultraviolet Quiet One Pump Filter Filter Module Sterilizer
4. ER CAP 220001 CAP O RING R172014 R172043 CUP SPRING CARTRIDGE PLUG R175056 CAP RETAINER CHAMBER R175029 RETAINER CHAMBER AF 93 ONLY R175054 RETAINER CHAMBER AF 93 19 ONLY R175055 RETAINER CHAMBER AF 93 29 ONLY a R270313 34 CLOSE NIPPLE R270484 1 CLOSE NIPPLE LiFEGARD EAR ALISS www lifegardaquatics com MODEL AF 94 MECHANICAL FILTER HOW TO CHARGE THE COMBINATION AQUARIUM CARTRIDGE 1 Unscrew module cap 2 Remove cup spring and cartridge plug 3 Remove cartridge from module 4 Fill inner cartridge core with coarse granular carbon or other media that will not pass through the inner retainer screen 5 Rinse carbon by letting water run down through open end of cartridge until clear 6 Install cartridge in filter module Make sure cartridge fits onto center hub in bottom of filter module Cartridge should protrude about As above module 7 Replace cartridge plug 8 Install cup spring large end over cartridge plug 9 Before replacing module cap make sure O ring is clean and lubricated with Lifegard Silicone and in place START UP INSTRUCTIONS 1 o1 amp W PO Thread gauge adapter and air bleed into cap Gauge adapter is sufficiently tightened with 1 or 2 threads showing on inside of cap Over tightening will break gauge adapter or interfere with cartridge Do not over tighten FINGER TIGHTEN ONLY Open air bleeder beneath the pressure gauge Begin water flow t
5. all threads Coat the O ring with Lifegard Silicone and replace cap on the module and HAND TIGHTEN ONLY Open inlet and outlet valve open the bleed valve on the pressure gauge until a few drops of water are expelled then close air bleed valve and start pumping WARRANTY POLICY Warranty period starts from date of purchase and must be validated with copy of original purchase receipt Warranty requests by phone will not be honored Warranty items returned without copy of original purchase receipt will not be honored Products purchased from EBay Craig s List etc cannot be honored for warranty unless returned by original purchaser with proof of purchase All items must first be returned to Lifegard Aquatics for inspection evaluation and processing to determine if product qualified for warranty replacement or repair No warranty repair replacement or credit will be issued prior to inspection of products Please contact us first for warranty assistance Many times the product can be repaired without the cost and time involved in sending it back to us If absolutely necessary return product freight prepaid to the following address for warranty evaluation and processing One year warranty on all Lifegard Modules Lifegard Aquatics 13911 Struikman Road Cerritos CA 90703 Tel 562 404 4129 Fax 562 404 4159 Email info lifegardaquatics com LAFEGARD AQUATICS Sas gt ANC Pond amp Aquaculture Products
6. hrough module Close air bleeder when a few drops of water are expelled To pre determine the pressure at which to change the filter pleats shut off outlet valve so that no water is allowed to flow back to the aquarium then record the pressure indicated maximum pump output The pleat change pressure will be one or two psi less than the maximum reading just obtained It is recommended that the change pressure be marked with a piece of tape as it may be quite some time before this pressure is reached WHEN TO CLEAN THE FILTER i When the gauge reaches the change pressure and or when the water flow has decreased considerably HOW TO CLEAN THE FILTER ROD O1 Shut off pump Shut off inlet and outlet valve installed below the level of the module cap Remove cap from module Remove cartridge retainers from pleats and pleats from cartridge Carbon or other media may be changed at this time Install new pleats by starting at the bottom of the cartridge and inserting one pleat into each of the 30 V shaped sections in the filter cartridge When the bottom of the filter pleats are completely seated simply run your hand up the filter pleats and the pleats will seat themselves along the entire cartridge Make sure the pleat retainers are seated properly To re charge cartridge refer to numbers 1 9 Before replacing module caps remove the O ring and thoroughly clean it as well as the O ring seat and