ACD-10 Pro and ACD-10 TRMS Pro Product Manual

image

Contents

1. uw I W CAUTION Measuring Resistance Continuity Diode or Capacitance function on a live circuit will produce false results and may damage the instrument In many cases the suspected component must be disconnected from the circuit to obtain an accurate measurement reading 8 Q Resistance and Continuity functions Inputs are made through the test leads terminals Slide switch on defaults at Q Press SELECT button momentarily to select Continuity function which is convenient for checking wiring connections and operation of switches A continuous beep tone indicates a complete wire Diode test function Inputs are made through the test leads terminals Slide switch on defaults at Q Press SELECT button momentarily 2 times to select gt Diode test function Normal forward voltage drop forward biased for a good silicon diode is between 0 400V to 0 900V A reading higher than that indicates a leaky diode defective A zero reading indicates a shorted diode defective An OL indicates an open diode defective Reverse the test leads connections reverse biased across the diode The digital display shows OL if the diode is good Any other readings indicate the diode is resistive or shorted defective Capacitance function Inputs are made through the test leads terminals Slide switch on defaults at Q Press SELECT button momentarily 3 times to select Capacitanc
2. reading digits number of digits or otherwise specified at 23 C 5 C amp less than 75 R H Model ACD 10 PRO TRMS True RMS accuracy of ACV is specified from 5 to 100 of range and ACA is specified from 10 to 100 of range or otherwise specified Maximum Crest Factor lt 1 75 1 at full scale amp lt 3 5 1 at half scale with frequency components within the specified frequency bandwidth for non sinusoidal waveforms DC Voltage ACD 10 PRO TRMS PRO Accuracy 0 3 4d 0 5 3d NMRR gt 50dB 50 60Hz CMRR gt 120dB DC 50 60Hz Rs 1kQ Input Impedance 10MQ 30pF nominal 1000MQ for 400 0mV range AC Voltage ACD 10 PRO TRMS PRO OHZ 500Hz 1 5 5d 2 0 5d CMRR gt 60dB DC to 60Hz Rs 1kQ Input Impedance 10MQ 30pF nominal Max Hold where applicable Specified accuracy 50 digits for changes gt 2oms in duration Audible Continuity Tester Audible threshold between 20Q 1200 Capacitance ACD 10 PRO TRMS PRO RANGE 500 0nF 5 000pF 3 5 6d 50 00uF 500 0uF 3000uF Additional 50 00nF range accuracy is not specified Accuracies with film capacitor or better Specified with battery voltage above 2 8V approximately half full battery Accuracy decreases gradually to 12 at low battery warning voltage of approximately 2 4V 13 AC CURRENT ACD 10 PRO TRMS PRO Accuracy 1 1 9 8d Accuracy specified to 350A continuous and 4
3. 00A for 60 second max with 5 minutes cool down interval Added range to indicate instantaneous over range current values OHMS ACD 10 PRO TRMS PRO RANGE Accuracy 400 0Q 0 8 6d 4 000 40 00kQ 0 6 4d 400 0kQ 40 00MQ 2 0 4d Open Circuit Voltage 0 4VDC typical Diode Tester ACD 10 PRO TRMS PRO Open Circuit Voltage Test Current Typical lt 1 6 VDC 0 25mA Hz Frequency ACD 10 PRO TRMS PRO Sine RMS 00 0mV 150 10Hz 2kHz 000V 5Hz 40kHz 100kHz SHz 100kHz SHz 5 2 Display counts 5000 Best resolution 0 001Hz Accuracy 0 5 4d 14 LIMITED WARRANTY Your AMPROBE instrument has a limited warranty against defective materials and or workmanship for one year from the date of purchase provided that in the opinion of the factory the instrument has not been tampered with or taken apart Should your instrument fail due to defective materials and or workmanship during this one year period please have your dated bill of sale which must identify the instrument model number and serial number and call the number listed below Repair Department ATP AMPROBE MIRAMAR FL Tel 800 327 5060 www amprobe com SPX G Advanced Test Products Miramar FL Tel 954 499 5400 Fax 954 499 5454 ED PRINTED ON RECYCLABLE PAPER PLEASE RECYCLE COPYRIGHT MMII Btc ALL RIGHTS RESERVED P N 7M1C 0461 0000 PRINTED IN TAIWAN
4. Frequency functions Inputs are made through the test leads terminals Slide switch on defaults at DC voltage Press SELECT button momentarily to select AC voltage Press the Hz push button momentarily to activate Hz Frequency function in the following slide switch functions DCV amp ACV via the test leads ACA via the jaw clamp 6 Note DC 400 0mV range is designed with 1000MQ high input impedance for least current drain in measuring small signals and can cope better with most commercially available voltage output transducers adapters The non zero display reading is normal when the meter inputs are open circuit which will not affect actual measurement accuracy The meter will show close to zero reading when the inputs are shorted Open input is actually a floating condition which is not a zero volt input condition Note Hz input sensitivity varies automatically with function range selected while activating the Hz function Lowest range has the highest sensitivity and the highest range has the lowest sensitivity Activating the Hz function while measuring the specific function signal auto ranging can automatically select the best sensitivity range to avoid electrical noise which may cause unstable Hz reading However if the Hz reading shows zero due to insufficient sensitivity activate the Hz function BEFORE measuring the specific function signal The meter is then in the lowest range and can select the highest sensitivity
5. INSTRUCTION MANUAL ACD 10 PRO amp TRMS PRO AN 1 Congratulations You are now the owner of an AMPROBE Instrument It has been quality crafted according to quality standards and contains quality components and workmanship This instrument has been inspected for proper operation of all of its functions It has been tested by qualified factory technicians according to the long established standards of AMPROBE 1 SAFETY This manual contains information and warnings that must be followed for operating the instrument safely and maintaining the instrument in a safe operating condition If the instrument is used in a manner not specified by the manufacturer the protection provided by the instrument may be impaired The meter meets the requirements for double insulation to IEC61010 2 032 1994 EN61010 2 032 1995 UL3111 2 032 1999 ACD 10 PRO TRMS PRO Category 11 600 Volts ac and dc Category 111 300 Volts ac and dc PER IEC61010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY II Equipment of OVERVOLTAGE CATEGORY Il is energy consuming equipment to be supplied from the fixed installation Note Examples include household office and laboratory appliances OVERVOLTAGE CATEGORY III Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations Note Examples include switches the fixed installation and some equipment for industrial use with permanent connection to the fixed instal
6. as the reference value The display will now show readings relative to the stored reference value That is display reading stored value Press the A button momentarily to activate and to exit relative zero mode Auto ranging Where there is more than one measuring range under a selected meter function the LCD annunciator turns on The meter will automatically switch to the best resolution range when making measurements No manual ranging selection is required Auto Power Off APO When the meter is on the Auto Power Off APO feature will switch the meter into a sleep mode automatically to extend battery life after approximately 30 minutes of the last front panel activity To wake up the meter from APO press the buttons momentarily or set the Slide switch to the OFF position and then slide back on again Always set the slide switch to the OFF position manually when the meter is not in use 5 MAINTENANCE WARNING To avoid electrical shock disconnect the meter from any circuit remove the test leads from the input jacks and turn OFF the meter before opening the case Do not operate with open case 11 Trouble Shooting If the instrument fails to operate check batteries and test leads etc and replace as necessary Double check operating procedure as described in this user s manual If the instrument voltage resistance input terminal has been subjected to high voltage transient caused by lightning or switching surge to th
7. e function Relative zero A mode can be used to zero out the parasitic capacitance of the leads and the internal protection circuitry of the meter when measuring low capacitance in the order of Pico Farad pF CAUTION Discharge capacitors before making any measurement Large value capacitors should be discharged through an appropriate resistance load ACA Current clamp on function Inputs are made through the jaws clamps for non invasive ACA current measurements CAUTION Press the jaw trigger and clamp the jaws around only one single conductor of a circuit for load current measurement Make sure the jaws are completely closed or else it will introduce measurement errors Enclosing more than one conductor of a circuit will result in differential current like identifying leakage current measurement Strong Electro magnetic field environments such as high current transformers motors and conductors may affect measurement accuracy 10 HOLD The hold feature freezes the display for later viewing Press the HOLD button momentarily to activate or exit this feature MAX The max feature compares and displays the measured maximum value as fast as 30ms with auto ranging capability Press the MAX button for 1 second or more to activate or exit the max feature in the following functions DCV ACV amp ACA Relative zero A mode Relative zero A mode allows the user to offset the meter consecutive measurements with the displaying reading
8. e system by accident or abnormal conditions of operation the series fusible resistors will be blown off become high impedance like fuses to protect the user and the instrument Most measuring functions through this terminal will then be open circuit The series fusible resistors and the spark gaps should then be replaced by qualified technician Refer to the LIMITED WARRANTY section for obtaining warranty or repairing service Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent do not use abrasives or solvents If the meter is not to be used for periods of longer than 60 days remove the batteries and store them separately Battery replacement The meters use standard 3V alkaline button battery ANSI NEDA 5004LC IEC CR2032 In models ACD 10 PRO amp ACD 10 TRMS PRO one battery are used Loosen the two screws from the case bottom and remove the bottom case Slide the battery out the side of the holder and replace with a new battery observe polarity Replace the bottom case Re fasten the screws 6 Specifications General Specifications Display 3 3 4 digits 4000 counts LCD display s Update Rate 3 per second nominal Polarity Automatic Low Battery Indication Below approx 2 4V Operating Temperature 0 C to 40 C Relative Humidity Maximum relative humidity 80 for temperature up to 31 C decreasing linearly to 50 relative humidity at 40 C Altitude Operating below 2000m Storage Te
9. eads from the test points before changing meter functions INTERNATIONAL ELECTRICAL SYMBOLS Caution Refer to the explanation in this Manual Caution Risk of electric shock Earth Ground Double Insulation or Reinforced insulation Fuse AC Alternating Current DC Direct Current otep 2 CENELEC Directives The instruments conform to CENELEC Low voltage directive 73 23 EEC and Electromagnetic compatibility directive 89 336 EEC 3 PRODUCT DESCRIPTION 4 This user s manual uses only representative model s for illustrations Please refer specification details for function availability to each model AX SELECT 1 Transformer Jaw Clamp for AC current magnetic field pick up 2 Hand Finger Barrier to indicate the limits of safe access of the meter during measurement 3 Push buttons for special functions amp features 4 Push buttons for special functions amp features on Slide switch Selector functions 5 Input Jack for all functions EXCEPT non invasive ACA current function 6 Common Ground reference Input Jack for all functions EXCEPT non invasive ACA current function 7 Slide switch Selector to turn the display power ON OFF and Select a function 8 3 3 4 digits 4000 counts LCD display 9 Jaw trigger for opening the transformer clamp jaw 4 OPERATION JA AMPROBE SELECT JE DC Voltage AC Voltage Hz
10. lation OVERVOLTAGE CATEGORY IV Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation Note Examples include electricity meters and primary over current protection equipment 2 TERMS IN THIS MANUAL WARNING identifies conditions and actions that could result in serious injury or even death to the user CAUTION identifies conditions and actions that could cause damage or malfunction in the instrument WARNING To reduce the risk of fire or electric shock do not expose this product to rain or moisture The meter is intended only for indoor use To avoid electrical shock hazard observe the proper safety precautions when working with voltages above 60 VDC or 30 VAC RMS These voltage levels pose a potential shock hazard to the user Inspect test leads connectors and probes for damaged insulation or exposed metal before using the instrument If any defects are found replace them immediately Do not touch test lead tips or the circuit being tested while power 1 applied to the circuit being measured To avoid accidental short circuit of bare uninsulated hazardous live conductors or busbars switch them off before insertion and removal of the current clamp jaws Contact with the conductor could result in electric shock Keep your hands fingers behind the hand finger barriers that indicate the limits of safe access of the meter and the test leads during measurement CAUTION Disconnect the test l
11. mperature 20 C to 60 C lt 80 R H with battery removed Temperature Coefficient nominal 0 15 x specified accuracy C 0 C 18 C or 28 C 40 C or otherwise specified 12 Sensing Average sensing for ACD 10 PRO True RMS for ACD 10TRMS PRO Safety Meets IEC61010 2 032 1994 EN61010 2 032 1995 UL3111 2 032 1999 For ACD 10 PRO TRMS PRO Category II 600 Volts AC amp DC and Category 300 Volts AC amp DC Transient protection 6 5kV 1 2 50us surge for all models Pollution degree 2 E M C Meets EN61326 1997 1998 A1 EN61000 4 2 1995 and EN61000 4 3 1996 In an RF field of 3V m Capacitance function is not specified Other function ranges Total Accuracy Specified Accuracy 45 digits Performance above 3V m is not specified Overload Protections ACA Clamp on jaws AC 400A RMS continuous amp COM terminals all functions 600VDC VAC RMS Power Supply 3V alkaline button battery ANSI NEDA 5004LC IEC CR2032 One battery for ACD 10 PRO amp ACD 10 TRMS PRO Power Consumption 2 5 mA typical APO Timing Idle for 30 minutes APO Consumption 0 8uA typical on all functions except on ACD 10 TRMS PRO Amps and Volts where it is 25uA Dimension L 7 8 X W 2 48 X H 1 25 Weight 0 412 Lb approx Jaw opening amp Conductor diameter 1 02 max Accessories Test leads pair battery installed user s manual amp soft carrying pouch Electrical Specifications Accuracy is

Download Pdf Manuals

image

Related Search

Related Contents

Mac OS X Server File Services Administration  Beko D1 5102 B Washer User Manual  Atdec TH-3070-CTL flat panel ceiling mount  N - Achatplus    cedoC-Tech.fr  INSTRUCTIVO DE INSTALACION Y MANUAL DEL PROPIETARIO  こちらをクリック※PDFファイルが開きます。  E44286_Ultrasonic Cleaner_CH_IM - GT  Sony CDX-FW700 Operating Instructions  