1. Application files axx Firmware files fw Language files s Licence file key System files VivaSystem zip 73 Viva TPS Uploading System Files 74 Appendix B Uploading System Files Tips and Tricks e Uploading objects can take some time Ensure that the battery is at least 75 full before beginning the upload and do not remove the battery during the upload process e Applications will be installed in English and in any other language that is already loaded onto the instrument If a new language is loaded after an application has been installed the application will need to be reinstalled to become available in the new language e It is not possible to have more than three language files stored on the instru ment English is always available as the default language and cannot be deleted o Copy the object to upload into the SYSTEM directory of the data storage device and insert the device into the instrument Firmware files use the extension fw application files use the extension axx and language files use an extension that is individual to each language Uploading firmware applica tions or languages step by step Job fixpoint job Go to Work i Jobs amp Data Instrument ENESA EB Work settings Field to office B Format data storage devices View contents of ASCII files 0 010m Fn abc 14 17 Language SD card German
2. 9 489m_ Fn abc ew System language upload was successful Do you wish to use this language Support ID 103 15 023m 1DCQ 12 24m Fn abc 14 16 Viva TPS Uploading System Files From the Main Menu select User Tools amp other utilities Load firmware amp Apps Object to transfer Select the type of object to upload From Select the data storage device where the object is located App Firmware Language Select the file name of the object Select OK to upload the object onto the instru ment The upload process can take some time A message will appear when the upload is complete 75 Viva TPS Leica Geo Office 76 Appendix C Description Transferring files to LGO step by step Leica Geo Office Leica Geo Office LGO is an office software consisting of a suite of standard and extended programs for the viewing exchange and management of data Jobs codelists and other related files can be transferred from the instrument or data storage device to LGO for post processing In LGO the Data Exchange Manager enables data to be transferred between an instrument and a computer The Import Raw Data function in LGO imports the data from the computer or data storage device into an LGO project Step Description l e f data is located on a data storage device insert the device into the appropriate slot or port of the computer Go to step 7 e f data is located on the instrument connect the
3. 2 2 Operating Principles Accessing wi Description Illustration option There are three ways to access a menu option EMMAA 1 Using the touchscreen functionality Tap on OLIES ma the menu item using the stylus provided E View amp edit data 3 Job properties 4 Choose working job 2 Using the up and down navigation arrows E Choose control job Import data Move the focus to the menu item Select OK Export amp copy di or press the OK 8 button or the ENTER L button 3 Using the numbered keypad Select the number that corresponds to the menu item For example press 1 from the Jobs amp Data menu to access the New job screen Accessing a f Description selectable list A downward arrow beside a field indicates there are more choices available in a selectable list A box and a downward arrow beside a field indi cates that there are more choices and function ality available in a separate screen To access the list or screen use the touchscreen functionality to tap on the icon or move the focus to the field and press the ENTER gt button Illustration Device CF card Ed Customer1_v3 Accessing a page A Description within a screen To access another page within a screen either e Tap on the page tab for the page to be displayed or e Select Page until the page is displayed Illustration New Job General Codeli
4. Version 1 0 English Leica Viva TPS Getting Started Guide when it has to be right Seica Geosystems Viva TPS Introduction 2 Introduction To use the products in a permitted manner please refer to the detailed safety instructions in the Leica CS10 CS15 User Manual Leica GS10 GS15 User Manual and Leica TPS1200 User Manual S For detailed descriptions of all functions and settings of the product and applications please refer to the Leica Viva Series Technical Reference Manual Purpose of this This Getting Started Guide is intended as a quick field reference manual for immedi manual ately getting started with your Leica Viva Series equipment The manual explains what you can find in your container how everything fits together and how to get started on the basic applications Quick references mae Topic Refer to to specific topics What s in my container Chapter 1 1 How does the equipment all fit together Chapter 1 2 What is this first screen see when I turn on my instrument Chapter 2 1 How do I get to the Main Menu Chapter 2 1 How do I select things and move around the screens Chapter 2 2 What are wizards Chapter 2 2 Topic Refer to How do get started with jobs and codelists Chapter 3 How to use the applications Chapter 4 m world myWorld Leica Geosystems https myworld leica geosystems com offers a Leica Geosystems wide range of services
5. from the context menu 13 Select the Assign button to import the data into the selected project Viva TPS Leica Geo Office 79 Total Quality Management Our commitment to total customer satisfaction Leica Geosystems AG Heerbrugg Switzerland has been certified as being equipped with a quality system which meets the International Standards of Quality Management and Quality Systems ISO standard 9001 and Environmental ISO 9001 1SO 14001 Management Systems ISO standard 14001 Ask your local Leica Geosystems dealer for more information about our TQM program Leica Geosystems AG Heinrich Wild Strasse CH 9435 Heerbrugg Switzerland Phone 41 71 727 3131 www leica geosystems com when it has to be right C REV mE Cass O S s 5 AA TOF Bh CO z E N F N g M lt Ww E w T A O w UO E Or O O N Geosystems
6. Devices From the Main Menu select User Tools amp other utilities Format data storage devices Memory Device Select the device to format Select OK to continue with the formatting Select Yes to complete the formatting of the memory device OR Select No to cancel formatting of the memory device and return to Format Data Storage Device Once the formatting of the memory device is completed the system returns to the Main Menu 71 Viva TPS Working with Memory Devices 72 A 2 Directory Structure of the Memory Device Directory structure CODE e Codelists various files I CONFIG e Working style files xfg I CONVERT e Format files frt DATA e ASCII DXF LandXML files for import export to from job e Report sheets created from applications GPS I CSCS e CSCS field files csc GEOID e Geoid field files gem RINEX e RINEX files DBX e DTMjobs various files e Coordinate system file Trfset dat JOB DOWNLOAD GPS GSI SYSTEM Viva TPS Working with Memory Devices Job files various files Jobs are stored ina folder per job Various files downloaded by Field to office application Antenna file List ant GSM Modem station list fil Server list fil GSI files gsi ASCII files for export from job
7. ESC Entry mode Fn Can be used with touch screen Same functionality as the fixed key ESC The last operation will be undone The caps mode for upper case letters is active The caps mode is activated and deactivated by pressing the CAPS key Switches between the first and second level of function keys Softkeys Commands can be ran using F1 F6 keys only applicable for CS15 field controller The commands assigned to the softkeys are screen dependent Can be used directly with touch screen Common softkeys The softkeys following are used commonly in the Leica SmartWorx Viva software across all applications Softkey Function Key Description OK F1 To select the highlighted option and to continue with the subsequent screen Page F6 To change to another page on the current screen Help Fn F1 To open the Leica SmartWorx Viva online help Home Fn F2 To move the focus to the top of the list shown in the current screen End Fn F3 To move the focus to the bottom of the list shown in the current screen Quit Fn F6 To exit the current application and return to the screen from where the application was accessed Viva TPS SmartWorx Viva and Principles 27 Viva TPS SmartWorx Viva and Principles 28 2 1 2 Description ee Icon bar TPS Mode Icons The screen icons display the status information of the instrument The icons provide information related to basic instrum
8. Information and training material With direct access to myWorld you are able to access all relevant services whenever it is convenient for you 24 hours a day 7 days per week This increases your effi ciency and keeps you and your equipment instantly updated with the latest informa tion from Leica Geosystems Service Description myProducts Simply add all Leica Geosystems products that you and your company own View detailed information on your products buy additional options or Customer Care Packages CCPs update your products with the latest software and keep up to date with the latest documentation Viva TPS Introduction Viva TPS Introduction Service Description myService mySupport myTraining View the service history of your products in Leica Geosystems Service Centers and detailed information on the services performed on your products For your products that are currently in Leica Geosystems Service Centers view the current service status and the expected end date of service Create new support requests for your products that will be answered by your local Leica Geosystems Support Team View the complete history of your Support and view detailed information on each request in case you want to refer to previous support requests Enhance your product knowledge with the Leica Geosystems Campus Information Knowledge Training Study the latest online training material or download trainin
9. Near HdnPt Page 59 Viva TPS Applications Select Code Code description Traffic Sign Pt Traffic Sign Brd Traffic Sgn Post Survey Code Map Point ID Code Diameter 0 016m Fn abc 14 21 HdnPt Page Meas Near Enter Mandatory Attribute __ hay EL Description Light Pole 0 02im 2DCQ 0 01im 1DCQ 0 0i7m Last Default Fn abc 14 22 60 Selecting the code e Highlight Code and select the code EL for Elec tric Light pole To select the code EL toggle to the code or type in the letters to open the drop down list and search for the code gt You have to enter capitals Measuring the point object e When the code is selected press Meas to measure the point object e After the measurement has been stopped the Enter Mandatory Attribute screen will appear since the attribute Diameter is mandatory and is currently blank e Enter a diameter of 300 mm and press OK to store the point Survey Customer 1 You have finished measuring your first IED Code GE point object eae Once the point is stored then the code and Diameter attribute value that was stored are displayed 3DC 20 Fn abc 14 23 Meas Near HdnPt Page Viva TPS Applications 61 Viva TPS Applications 4 3 Objective Staking out point objects step by step 62 Stakeout Staking out point objects To make your life ea
10. Stakeout a Aen Stake to ref line 0 015m_ Fn abc 14 29 e Select Measure to ref line and continue OK 0 015m_ Fn abc 14 30 67 Viva TPS Applications 68 Reference Line Startup wm Define the Reference line task Reference line task ESO e Set Reference line task Measure to line and Measure points relative to a defined line while continue OK constantly viewing your position relative to the line 0 009m 1DCQ 0 016m Fn abc 14 30 Choose Control Job Choose Control Job Height touse stort poit e Select the job which contains the points used to define the reference line e Press OK to access Reference Line To Use screen Choose control job 0 017m Fn abc 14 31 Define the reference line to be used om e Set Create line using 2 points Point0001 e Select a Start point Point0002 Line length 22 361m Select an End point e Press OK to access Measure Points screen 0 008m 1DCQ 0 012m_ Fn abc 14 33 Measure Points Ref Line Map Point ID Antenna height A offset Aline A ht start of line Elevation 2 000 0 003m 0 005m 1 995m 467 742m 0 008m 1DCQ 0 012m Fn abc 14 35 Line Stake Page Viva TPS Applications Measure the point object relative to the refer ence line e In the Measure Points screen press Meas to measure the point CS You have fini
11. instrument to the computer This connection can be via the docking station a USB cable a Bluetooth connection or for TPS via a RS232 serial cable Go to step 2 2 Select Tools Data Exchange Manager to open the Data Exchange Manager window Step Description Right click in the Data Exchange Manager window and select Settings e For a USB connection ensure that the USB port settings are config ured for the instrument type being connected e Fora Bluetooth or RS232 serial cable connection ensure the instru ment interface settings and the computer COM settings are config ured correctly Select OK to close the Setting window In the folder directory on the left of the Data Exchange Manager window open the Serial Ports or USB COM node to which the instrument is connected Highlight the object to transfer In the folder directory on the right open the My Computer Files folder location Select a folder on the computer hard drive where the object can be transferred to and saved Drag and drop or copy and paste the object from the directory on the left side to the selected folder on the right side All object specific files will be copied to the selected folder on the computer hard drive To import the files into LGO select Import Raw Data or select the Sa icon from the toolbar Viva TPS Leica Geo Office 77 Viva TPS Leica Geo Office Step 78 Description 8 In
12. 6 50 CS You have completed importing ASCII data into your current working job G Applications Getti ng started Working Style Wizard Choose the working style to use Working Style Customer 1 Eag customer 1 Description Default Creator 0 016m_ 2DCQ 0 009m 1DCQ 0 013m Fn abc _ 14 20 Choose working job CF card Customer 1 10 020m 2DCQ 0 0i1im 1DCQ 0 017m Fn abc 14 18 OK New Edit Delete Data SD card Viva TPS Applications Check that the correct working style see User Working style wizard is being used Check that the correct working Job see Jobs amp Data Choose working job is being used 51 Viva TPS Applications 52 4 1 Setup Objective Determine the station coordinates and the orientation of your TPS instrument using TPS measurements and or GNSS measurements Setting up with Job fixpoint job Starting Setup SmartStation step aS e In the Go to Work menu select Setup by step e Choose one of the following setup methods Known backsight and select OK Station is known i Measure to 1 known Set orientation target point to set E orientation Known backsight Multiple backsights Transfer height These are the only methods applicable for a setup with SmartStation Set Station Point Station point from GPS SmartStation Y Instrument height 800 Survey fixpoint job Survey Cod
13. Jobs amp Data and press OK e Select New job from the Jobs amp Data menu and press OK 41 Viva TPS Jobs amp Data General Codelist CAD files Coord system TPS scale Name MEE Description sedis Creator Leica Customer Device CF card Use with System1200 0 011m 2DCQ 0 006m 1DCQ 0 009m Fn abc 15 27 Job My first job Go to Work 1 a Survey amp stake pts Jobs amp Data ey Point management Start base station Import amp export gO 2 Settings amp status c 3 Software settings a Connections W Screen amp audio 3 Instrument 4 e User 0 011m_ 2DCQ 0 006m 1DCQ 0 009m Fn abc _ 15 26 42 e Enter a name for the Job e Use Page to toggle between the pages to set the proper Codelist CAD files Coord system TPS scale and Averaging e Press Store to save the job CS You have finished creating your first job which is selected as current working job You will automatically return to the Main Menu and are ready to start the next activity 3 2 Creating a Codelist Creating a codelist Generals steps to create your first codelist in SmartWorx Viva Step by step Job My first job Creating your first codelist Go to Work Jobs amp Data e From the Main Menu select Jobs amp Data and A Survey amp stake pts ey Point management Import amp export Dress OK Start base station ou Instrument User JO 2 Settin
14. e Annot Map Point ID PS000 Antenna height 1 5800 3 9566m Fn abc 14 40 Meas Near HdnPt Page Viva TPS Applications Setting the station point e Station point from Select GPS SmartStation e Instrument height Enter the height of the instrument station Ensure that the GS15 instrument is connected to the CS field controller and the correct antenna type is set This will ensure the vertical offset between the TPS and GS15 instrument is accounted for e OK to access the GPS Survey screen Measuring the station point e Meas to start the point measurement e Stop to end the point measurement e Store to store the point information 53 Viva TPS Applications Local to enter local coordinates for the setup point CrdSys to select an existing coordinate system Support ID 482 V CoordSys Name Station ID Easting Northing Elevation My coord system GPS0003 500 0000 500 0000 20 0000 Fn abc 14 44 54 Selecting a coordinate system If a coordinate system has not been selected OR Local to access One Pt OneStep CrdSys to access Coordinate Systems to select an existing coordinate system On this screen the creating and editing of coordinate systems is also available CoordSys Name Enter a name for the local coordinate system Enter local coordinates for the setup point OK to set t
15. ed e Press OK to return to the New Codelist screen 0 01im 2DCQ 0 006m 1DCQ 0 009m Fn abc 17 18 OK New Edit Delete More Viva TPS Jobs amp Data 45 Viva TPS Jobs amp Data 46 New Codelist Storing the codelist os e Press Store to save your codelist You will auto D iption My ist codelist a a matically return to the Codelists screen Creator User Fn abc 17 07 Store Codelists e Press OK to return to Job Properties Codelist page User Couelist e Press Store to save your job and to return to the Main Menu Job My first job gt You have created your first codelist with a Go to Work rs Jobs amp Data code and a code group and attached it to 1 jen Survey amp stake pts Point management Start base station Import amp export your current working job wy Instrument User JO a2 Settings amp status g Software settings a Connections Screen amp audio 0 006m 1DCQ 0 009m Fn abc 15 26 3 3 Objective Se Import ASCII data step by step Importing ASCII Data into a Job Importing point objects into the working job by using the Import ASCII data function ality At least one ASCII file with any file extension must be stored in the DATA directory of the internal memory or data storage device Job My first job Starting the ASCII Importer e From the Main Menu select Jobs amp Data Go to Work Jobs amp Data 5 Survey a
16. ent functions The icons that appear depend upon which instrument is used and the current instrument configu ration bD c d i ho Il O m ome eg d SYS13_026 a Automatic aiming f Camera b Prism g Line area auto points c Measure mode h Memory storage SD card Compact d Instrument face I amp II Compensator Flash card USB stick internal level memory e Current active instrument i Battery level field controller instru ment Icons Icon Automatic aiming DOK Prism QEA Measure mode Description Displays the current automatic aiming or PowerSearch settings Displays the selected prism Displays the selected measurement mode The red laser icon will display when the red laser is active Compensator level and instrument face or II SKA T Displays the compensator is off or out of range icons or the instrument face I or Il icon Viva TPS SmartWorx Viva and Principles 29 Viva TPS SmartWorx Viva and Principles Icon 30 Description Current active instru ment Ell Kel B Jal ET Displays the instruments that are currently configured and active When more than one instrument is configured the instrument at the front of the icon is the active instrument Camera TO Select this icon to begin the camera function Data management o moO aL TE Memory storage wanne Battery es e Gs Select this icon to open the data mana
17. eturn to the Import ASCII Data screen OK e Enter the Define Ht Type amp Easting Import screen Fn Hts 0 014m 2DCQ 0 008m 1DCQ 0 011m Fn abc 14 43 Import ASCII Data From CF card Data From file Point obje To job My first job Header lines None type to import ASCII data 014 0 012m 2DCQ 0 007m 1DCQ 0 010m Fn abc 14 42 Config View Import ASCII Data From Data From To jo Head Information Import of data completed 1000 points imported 0 records skipped Do you wish to import any more data Support ID 1070 0 011m 2DCQ 0 006m 1DCQ 0 009m Fn abc _ 14 43 Viva TPS Jobs amp Data Define height type and Easting import e Define how heights Orthometric or Ellip soidal and how the Easting is imported e Confirm the configuration settings and return to the Import ASCII Data screen OK Importing the ASCII data Import the ASCII data to the working job OK After importing the ASCII data to the working job complete the import No and return to the Main Menu or import another ASCII data Yes 49 Viva TPS Jobs amp Data Job My first job t Go to Work Jobs amp Data A Survey amp stake pts fa Point management Start base station Import amp export 3 Software settings Screen amp audio Instrument 4 e User JO Settings amp status ss Connections 0 006m 1DCQ 0 009m Fn abc 15 2
18. eys F7 F12 CAPS Lock Function keys F1 F6 Favourites ESC ENTER Backspace Volume Alpha keys ENTER SPACE 23 Viva TPS SmartWorx Viva and Principles Start using Smart SmartWorx StartUp Wizard i Li Worx Viva Welcome to SmartWorx Viva feica Geosystems when it has to be right O Don t show this panel during StartUp Fn abc 09 12 Turn on your CS field controller and start SmartWorx Viva Turn on your GS GNSS or TPS instrument For information about wizards refer to Wizards 24 2 1 1 Screen Screen CS15 field a _ T gt controller Q B Ja i ha E b PARTAA 9 i Go to Work 2 Jobs amp Data gt Setup total station Point management Survey amp stake pts Import amp export a Icons b Title C c Screen area gt Instrument Dao User d Message line 2 Settings amp status g Software settings ok Connections Display amp audio g e Softkeys h f ESC d M Pac Fn abe 1628 g Fn h Entry mode SYS13_028 i Ti me Elements Element Description Time The current local time is shown Title Name of the screen is shown Screen area The working area of the screen Message line Messages are shown for 10 s Viva TPS SmartWorx Viva and Principles 25 Viva TPS SmartWorx Viva and Principles Element 26 Description Icons Shows status information of the instrument Refer to 2 1 2 Icons Can be used with touch screen
19. g material on your products Keep up to date with the latest News on your products and register for Seminars or Courses in your country Table of Contents In this manual Chapter Page 1 Equipment 7 1 1 Container Contents 7 1 2 Setting Up the TPS Instrument 11 1 3 Setting Up SmartStation 13 1 4 Setting Up SmartPole 15 1 5 Setting up for Remote Control with the RadioHandle 16 1 6 Setting up for Remote Control with the TCPS28 17 1 7 Fixing the CS to a Holder and Pole 19 2 SmartWorx Viva and Principles 23 2 1 SmartWorx Viva 23 2 1 1 Screen 25 2 1 2 Icons 28 2 1 3 Main Menu 33 2 2 Operating Principles 36 2 3 Connecting TPS instrument and CS field controller 40 Viva TPS Table of Contents 5 Viva TPS Table of Contents 3 Jobs amp Data 41 3 1 Creating a New Job 41 3 2 Creating a Codelist 43 3 3 Importing ASCII Data into a Job 47 4 Applications 51 4 1 Setup 52 4 2 Survey 59 4 3 Stakeout 62 4 4 Reference Line 67 Appendix A Working with Memory Devices 70 A 1 Formatting a Memory Device 70 A 2 Directory Structure of the Memory Device 72 Appendix B Uploading System Files 74 Appendix C Leica Geo Office 76 1 1 1 Container for instrument and delivered accesso ries part 1 of 2 Viva TPS Equipment Equipment Container Contents GHT196 tribrach bracket for height metre Data transfer cable GFZ3 or GOK6 diagonal eyepiece Counterweight for diagonal eyepiece Ins
20. gement pages for Points Lines or Areas If there are open lines or areas a symbol will appear in the icon Displays the status of the internal memory or data storage device Displays the status and location of the battery GNSS specific icons Icon Position status Oo Number of visible Satellites wW Contributing satellites BD eD E d 0 Description Displays the status of the current position As soon as this icon becomes visible the instrument is in a stage where practical operation can commence Displays the number of theoretically visible satellites above the configured cut off angle according to the current almanac Displays the number of satellites that are contributing to the currently computed position solution E The number of contributing satellites can differ from the number of visible satellites This differ ence can be because satellites cannot be viewed or because the observations to these satellites are considered too noisy to be used Real time device dn d O Viva TPS SmartWorx Viva and Principles Displays the real time device configured to be used 31 Viva TPS SmartWorx Viva and Principles 32 Icon Description Real time status Displays the status of the real time device configured to be used f F 2 1 3 Main Menu Main Menu Job My first job OK Go to Work 2 Jobs amp Data To select the highlighted option and Survey amp stake
21. gs amp status g Software settings a Connections Screen amp audio 0 006m 1DCQ 0 009m Fn abc 15 26 Job My first job e Select Job properties from the Jobs amp Data 2 lr Jobs amp Data zi E New job ele Ee Sri Instrument i User menu and press OK 2 View amp edit data 4 Choose working job Choose control job B Import data gt Export amp copy data 0 006m 1DCQ 0 009m Fn abc 15 59 Viva TPS Jobs amp Data 43 Viva TPS Jobs amp Data 44 Job Properties My first job e Press Page to change to the Codelist page e Tap on the selectable list to open the Codelists screen 0 006m 1DCQ 0 009m Fn abc 15 59 Data Page e Press New to create a codelist e Type in a Name Description and Creator are optional Description My ist codelist e Press Codes to open the Codes screen Creator User 0 006m 1DCQ 0 009m Fn abc 16 15 Creating a code e Press New to create a code Code description 0 006m 1DCQ 0 009m Fn abc 16 32 e Type in a Code EL and a Description Light n TAT Pole select the Code group Electric the Code group Eledric Code type Point and the Linework None Code type Point and create an attribute Diameter ee e Press Store to save the new code Diameter 0 009m Fn abc 16 43 The Code group has to be created first before it can be select
22. hand strap to your CS field controller or fix your CS field controller to a holder and pole 3 Turn on your TPS instrument and your CS field controller gt Ensure that your TPS instrument is ready for remote control The RCS mode is only available for the CS15 field controller while the GeoCOM mode is available for all CS field controllers 4 Start the SmartWorx Viva software Refer to 2 1 SmartWorx Viva 5 Select Main Menu Instrument Instrument connections TPS connection wizard to start the TPS connection wizard For detailed descriptions please refer to the Viva Series Technical Reference Manual 6 Follow the TPS connection wizard and connect your TPS instrument to your CS field controller 3 1 Creating a job step by step Viva TPS Jobs amp Data Jobs amp Data Creating a New Job General steps to create your first Job in SmartWorx Viva Job My first job __ Go to Work Survey amp stake pts Start base station 1 3 JO 2 Settings amp status Connections i Jobs amp Data Point management Import amp export Instrument 3 User Software settings W Screen amp audio A view amp edit data 3 Job properties 4 Choose working job Choose control job import data Export amp copy data 0 009m gt gt Fn abc 15 26 0 011m_ 2DCQ 0 006m 1DCQ 0 009m Fn abc 15 24 Creating your first job e From the Main Menu select
23. he coordinate system Set Station Orientation Setting the station orientation ae aE e Backsight ID Select the relevant point id for Target height 1 5670 the backsight point Computed direction e Dist to measure the point ene e Set to set the station orientation and return to the Main Menu V g Fn abc 14 45 Set Dist GPS More Page gt Now you have completed your setup with SmartStation Setting up with Job fixpoint job Starting Setup SmartPole step by e In the Go to Work menu select Setup step stakeout coco Roads Fn abc 14 20 Viva TPS Applications 55 Viva TPS Applications Total Station Setup Resection y Station is not known Measure to 2 or more known target points to compute station coordinates amp orientation Station ID Instrument height Point code Job Current scale x Use control job for the target points Fn abc 14 34 5001 1 5000 E fixpoint job Dd 1 000000000000 Hz 357 3657 V 99 9346 Fn abc 14 36 56 e Choose one of the following setup methods and select OK Multiple backsights Resection Known backsight These methods are the only methods applicable for a setup with SmartPole e The process for Setup method Resection is shown here Enter station information e Station ID Enter a name for the station e Instrument height E
24. height of all points being staked and set Height offset to 0 000 m 63 Viva TPS Applications 64 Configuration Graphics page Set Navigate direction ea aN Graphics EEE Following arrow and Navigate using In out left right Press OK to return to the Stakeout screen Navigate direction Tonorth Navigate using In out left right v Switch to bulls eye when 0 5m from target Beep faster when getting close to point 0 016m 2DCQ 0 009m 1DCQ 0 013m Fn abc 14 59 Stakeout Setting up filters Stake Map Point ID Tap on the box with the downward arrow right of the Point ID to open the Data screen All aree a i points stored in the control job are shown Antenna ht 2 000 0 011m_2DCQ 0 006m_1DCQ 0 010m Meas Near Revers Fn abc 15 52 Survy Page Data Customer 1 e Press Fn Filter to access Sorts amp Filters Points Map Point Point code screen Point0001 0 018m 2DCQ 0 010m 1DCQ Help Home End Log Filter Quit Wabe 15 02 Sorts amp Filters Points Sort by Ascending point ID Filter by 7 Fn abc 14 40 Group Use None Sorts amp Filters Sort by Ascending point ID Filter by en ee 0 012m 2DCQ 0 007m 1DCQ 0 010m Fn abc 15 00 Codes Stake Viva TPS Applications Set Filter by Point code Press Codes to access Point C
25. ltaneously pressing and holding in the two press clips 1 4 SmartPole setup Viva TPS Equipment Setting Up SmartPole TS_061 GS15 instrument Port 3 GRZ122 360 prism GLS12 cm GLS12F ft pole with snap lock positions CS field controller GHT62 holder and GHT63 clamp RH15 RadioHandle Communication side cover TPS instrument Tripod 15 Viva TPS Equipment 16 1 5 Setting up for Remote Control with the RadioHandle TPS CS setup for remote control with RadioHandle a 2 a 360 prism d u b Prism pole c CS field controller d GHT62 holder and GHT63 clamp e RH15 RadioHandle f Communication side cover g TPS instrument h Tripod TS_063 1 6 Setting up for Remote Control with the TCPS28 TPS CS setup for remote control with TCPS28 a 360 prism b Prism pole c CS field controller d GHT62 holder and GHT63 clamp e TPS instrument f Tripod g TCPS28 h External battery i Y cable TS_062 Viva TPS Equipment 17 Viva TPS Equipment Mount base radio to tripod step by step 18 Description The GHT43 tripod adapter is used to mount the TCPS28 to all Leica standard tripods and to optimise the radio transmission performance Attach the TCPS28 to the adapter and then attach the adapter to the tripod leg Adjust the angle of TCPS28 until it is vertical Adjust the location of the adapter on the tripod leg so that there are
26. mp stake pts fa Point management Start base station Import amp export JO Settings amp status Software settings ars Connections Screen amp audio Instrument a e User e Inthe Jobs amp Data menu select Import data E New job then Import ASCII data and access the Import view amp edit data ASCII Data screen 3 Job properties 4 Choose working job B Choose control job Viva TPS Jobs amp Data 47 Viva TPS Jobs amp Data Import ASCII Data 7 see From Data type to import From file To job Header lines CF card ASCII data My first job eae Point ID position Easting position Northing position Height position Code position Multi Spaces Import ASCII Data __ Data type to import From file To job Header lines ASCII data Point objects txt My first job None 9 0 008 Help Hts 48 e Select the data storage device the data type ASCII data the file to be imported the working job into which the data has to be imported and define whether header lines have to be considered e Enter the Configuration screen Config Configuring the ASCII Importer e Select the Delimiter e Define the position for Point ID Easting Northing Height and Code if applicable e Confirm the configuration settings and r
27. ng to the Measure Target screen then Meas to measure to each target point with TPS K When enough target points have been measured to calculate the station location the softkey Cale will appear Measure Target 3 e Calc to calculate the position of the station Point ID 020 Target height 1 5670 Hz angle 308 5820g V angle 100 0248g Slope distance Meas Dist Store GPS Calc Station Results Setting the station Results Station Quality Targets Plot Eusing A ease e Review the results of the station setup Northing 253120 9323m e Set to set the station position and return to Elevation 400 3878m the Main Menu New orientation 308 5822g i Apply the computed elevation for this station CS You have completed your setup with SmartPole Fn abc 15 41 Trgt Page 4 2 Objective Surveying point objects step by step Viva TPS Applications Survey Surveying point objects fire hydrants light poles etc by choosing codes manually Job Customer 1 Sta rting Su rvey Coe iS Jobs amp D Teaver eee e Inthe Go to Work menu select Survey and 7 Stakeout access Survey Survey E stakeout B coco Roads Switch to Base menu 0 010m 1DCQ 0 015m Fn abc 14 21 Survey Customer 1 d Switch to the Code page Survey Code Map Point ID Point000 Code lt None gt 0 008m 1DCQ 0 013m Fn abc 14 26 Meas
28. no metallic objects in the horizontal plane around the antenna CS Metallic objects near the antenna disturb radio transmissions gt To achieve the best performance from the TCPS28 mount it ina vertical position on the tripod leg approximately 30 cm from the top Cs Ifthe adapter is no longer able to retain its angle position the adjust ment bolt at the hinge can be tight ened slightly TS_065 1 7 Fixing the CS to a Holder and Pole Components of the The GHT62 holder consists of some components as shown in the diagram GHT62 holder GHT63 clamp a Plastic sleeve b Pole clamp c Clamp bolt GHT62 holder d Locking pin e Top clip Ye tte f Mounting plate extendable g Bottom clip h Tightening screw i Mounting arm Fixing the CS field controller and GHT62 to a pole step by step Description If you use the CS15 field controller extend the mounting plate of the holder first For an aluminium pole fit the plastic sleeve to the pole clamp Insert the pole into the clamp hole Viva TPS Equipment 19 Viva TPS Equipment 20 Step Description A Attach the holder to the clamp using the clamp bolt ce Adjust the angle and the height of the holder on the pole to a comfortable position 4 Tighten the clamp with the clamp bolt 5 Before the CS field controller is placed onto the mounting plate E ensure that the locking pin is pu
29. nter the height of the instrument station e Ifall your control points will come from GPS leave Use control job for the target points unselected Ensure that the GS15 instrument is connected to the CS field controller and the correct antenna type is set e OK to access the measure target points screens Measure Target 1 Point ID Target height 1 5670 Hz angle V angle 357 3656g 99 9343g Slope distance Meas Fn abc 14 37 Dist Store GPS Survey fixpoint job Survey Code Annot Map Point ID Antenna height 0000 GPS0009 4 0049m Fn abc 14 39 HdnPt Page 1 9410 357 3661g 99 9344g Viva TPS Applications Fn abc 14 40 Dist Store GPS Measuring the target points Target height Enter your prism height When moving to GPS Survey the correct vertical offset will be applied so you automatically have the correct antenna height GPS to first enter GPS Survey before returning to this screen Meas to start the point measurement Stop to end the point measurement Store to store the point information and auto matically return to Measure Target 1 in TPS mode Meas to measure to target point 1 with TPS Screen automatically updates to Measure Target 2 57 Viva TPS Applications 58 e Repeat the previous steps to measure the other target points GPS to first enter GPS Survey before returni
30. ode Filter screen Press None to set all codes to No Highlight code EL and press Use to activate it Press OK to return to the Sorts amp Filters screen Press Stake to access Stakeout Filter screen 65 Viva TPS Applications Stakeout Filter Stakeout Current height 467 735m Antenna ht Point0001 Current height 467 734m Antenna ht 66 e Set View Points to stake e Press OK three times to return to the Stakeout screen Staking out your first point object e Which is the closest point to you to stake out first Press Near to select the nearest point e Navigate to the point and press Meas e While measuring the point you still can see the differences between the coordinates of the design point and the coordinates of the point you measured e The next point in the list to be staked out is displayed after the point was stored CS You finished staking out your first point 4 4 Objective Measuring point objects relative to a reference line step by step Viva TPS Applications Reference Line Measuring or staking point objects fire hydrants light poles etc relative to a refer ence line Job Customer 1 Starting Measure to ref line eee Mal e In the Go to Work menu select Survey and E Stakeout access Survey menu 2 een CE Staking a reference line can also be B coco accessed under Go to Work
31. pts F Point management j j amp sahil orga Aiape to continue with the subsequent screen Fn Mode 9 Settings amp status Q Software settings modes Connections W Screen amp audio Fn Exit 0 006m 1DCO 0 009m Fn abc 15 18 To close Leica SmartWorx Viva soft ware Main Menu func Description tions Go to Work e To select and start an application Viva TPS SmartWorx Viva and Principles 33 Viva TPS SmartWorx Viva and Principles 34 Main Menu function Description 2 Jobs amp Data e To manage jobs data codelists GNSS antennas reflec fa tors and coordinate systems e To export data from a job on the instrument to a file on the memory device in a customised ASCII format or in DXF format e To import ASCII GSI or DXF data from a file on the memory device to a job on the instrument e To copy points between jobs 3 Instrument e To access all configuration parameters related to a a survey the instrument and the interfaces Ar Main Menu function Description User e To format the memory device e To upload files relevant for the instrument functionality for example firmware files language files and licence keys e To transfer data between the memory device anda Standard and simple FTP server e To view files on the memory device or the internal memory Viva TPS SmartWorx Viva and Principles 35 Viva TPS SmartWorx Viva and Principles 36
32. shed measuring your first point object relative to a reference line 69 Viva TPS Working with Memory Devices 70 Appendix A A 1 General Working with Memory Devices Formatting a Memory Device Formatting a memory device before storing data on it is required if the device is new or if all data on the device must be deleted By activating the format command all data will be lost Make sure that all important data on the device has been backed up before formatting If formatting the internal memory make sure that all important data is first transferred to the computer Formatting the memory device will make it incompatible with System 1200 instru ments To become usable with System 1200 again the device would need to be reformatted on a System 1200 instrument To exit the screen without formatting the memory device press the ESC key This returns to the previous screen without running the format command Fo rmatting a Job fixpoint job T Go to Work Jobs amp Data Instrument memory device E Work settings step by step Memory Device ard 3DCQ 0 024m_ 2DCQ 0 013m 1DCQ 0 020m Fn abc _ 14 23 g App Format Data Storage Device 8 CF card will be formatted amp all data will be lost Note that this card will then NOT be able to be used in System1200 instruments The card must be re formatted on a 0 019m Fn abc 14 21 No Viva TPS Working with Memory
33. sier you will define a filter before Staking out the point object The filter will be defined the way that only points with a certain code and those points which have not yet been staked will be available to be staked out gt To accelerate the working example skip the steps regarding the filters and proceed directly with staking out the point object Job Customer 1 Starti ng Stakeout Go to Work 6 Jobs amp Data Instrument i User E survey e Inthe Go to Work menu select Stakeout and access Stakeout B Survey E stakeout B coco 6 Roads Switch to Base menu Choose Control Job Choose Control Job Select the job which contains your point objects to be staked out Press OK to enter the Stakeout screen Control job Customer 1 e 0 008m 1DCQ 0 0i1im Fn abc 14 46 Stakeout Configuring Stakeout Press Fn Config to access the Configuration screen Point ID Point000 a Current height 467 737m Antenna ht Quit Configuration General Quality control Graphics Report sheet Allow height of point being staked to be edited Offset height of all points being staked Height offset 0 000 m 0 008m 1DCQ 0 012m Fn abc 14 59 Viva TPS Applications Configure the following settings General page Quality control page and Report sheet page Leave all settings unchanged Heights page Check Offset
34. st CAD files Coord system TPS scale Codelist ome Viva TPS SmartWorx Viva and Principles 37 Viva TPS SmartWorx Viva and Principles 38 Exiting a screen without making a change To exit a screen without making a change either Description Illustration e Tap on the return icon or e Press the ESC s gt button Wizards The wizards following are available to make your daily work easier Each of them lead you through a serious of steps performing tasks in a specific sequence For detailed descriptions of the wizards please refer to the Leica Viva Series Technical Reference Manual Wizard Description SmartWorx StartUp Define the behaviour of your instrument for a general Wizard Start up RTK rover wizard Set up your real time rover TPS connection wizard Connect your CS field controller with your TPS instrument Wizard Description Working style wizard Configure the parameters and functions of SmartWorx Viva so that it suits to your preferred method of working and save the settings in a working style Viva TPS SmartWorx Viva and Principles 39 Viva TPS SmartWorx Viva and Principles 40 2 3 Connecting TPS instrument and CS field controller setup step by step Connecting TPS instrument and CS field controller Step Description l Set up your TPS instrument Refer to 1 2 Setting Up the TPS Instrument 2 Fix either a
35. t into the unlocked position To unlock the locking pin push the locking pin to the left 6 Hold the CS field controller above the holder and lower the end of the CS field controller into the mounting plate Viva TPS Equipment Step Description Apply slight pressure in a downward direction and then lower the top part of the CS field controller until the unit is clicked into the holder The guides of the mounting plate aid in this action After the CS field controller is placed onto the mounting plate ensure that the locking pin is put into the locked position To lock the locking pin push the locking pin to the right TS_054 21 Viva TPS Equipment Detaching the CS from a pole step by step 22 Description Unlock the locking pin by pushing the locking pin to the left of the mounting plate Place palm over the top of the CS until fingers grip the bar of the holder underneath Push from the top of the CS toward the bar of the holder While in this position lift the top of the CS from the holder SmartWorx Viva and Principles 2 1 SmartWorx Viva Keyboard display CS15 I waaAdDanTmlA OW OOM 0 0 0 oloo FY 00 0 00 OH W W wO H CS 006 Viva TPS SmartWorx Viva and Principles o 3 3 Ta Home Arrow keys OK ON OFF Fn key Numeric keys Brightness Function k
36. temperatures around the instrument Extend the tripod legs to allow for a comfortable working posture Position the tripod over the marked ground point centring it as well as possible Viva TPS Equipment 11 Viva TPS Equipment 12 Step Description 2 Fasten the tribrach and instrument onto the tripod 3 Turn on the instrument by pressing PROG for 2 s Press SHIFT F12 to access STATUS Level amp Laser Plummet activating the laser plummet 4 Move the tripod legs 1 and use the tribrach footscrews 6 to centre the plummet 4 over the ground point 5 Adjust the tripod legs to level the circular level 7 6 By using the electronic level turn the tribrach footscrews 6 to level the instrument precisely 7 Centre the instrument precisely over the ground point 4 by shifting the tribrach on the tripod plate 2 8 Repeat steps 6 and 7 until the required accuracy is achieved 1 3 Setting Up SmartStation SmartStation setup step by step Step Description l Place the adapter for the GS15 instrument onto the instrument by simulta neously pressing and holding in the four push buttons E Ensure that the interface connection on the underside of the adapter is on the same side as the Communication side cover Viva TPS Equipment 13 Viva TPS Equipment TS_060 Step 14 Description Place the GS15 instrument onto the adapter by simu
37. the Import Raw Data window select the type of data to be imported in the Files of type drop down list Values are e Viva raw data e System 1200 raw data e GSI Observations e GSI Points only e Database points DBX GeoDB e LandXML K When importing GSI data click the Settings button to define addi tional import settings for how the TPS raw data will be imported to a project Browse through the folder directory and select the file or folder to import The file or folder can be on the computer hard drive or on the inserted data storage device 10 Select Import to proceed to the Assign window Step 11 12 Description In the Assign window before assigning the data to a project the following functionality is available e Select the TPS tab to preview the raw data On this page it is possible to select or deselect which data is assigned to the project e Select the Settings tab to modify the assign settings The settings available depend on the type of data to be imported e Select the Backup button to save if desired the raw data from a data storage device to the computer hard drive Select a directory from the browser and select OK to confirm e Select the Fieldbook button to generate a Fieldbook Report on the jobs to be imported To import the data to a project e In the General tab select an existing project from the list OR e Create a new project by right clicking and selecting New
38. trument with tribrach and standard handle or RadioHandle Protective cover for instrument and sunshade for objective lens Tip for mini prism GEB221 battery GMP101 mini prism Viva TPS Equipment Container for instrument and delivered accesso ries part 2 of 2 TS_053 Pocket knife Spare stylus Manuals 2 x CompactFlash cards and covers Allen key GKL211 battery charger Car adapter power plug for battery charger stored under battery charger Container for SmartPole Smart Station and deliv ered accessories part 1 of 2 Viva TPS Equipment GS15 instrument GEB211 GEB212 battery GRZ4 GRZ122 prism Radio antennas GRZ101 mini prism and GAD103 adapter Spare stylus Allen key GAD31 adapter CS10 field controller GHT62 holder GHT62 holder extended CS15 field controller SD card CompactFlash card and covers Viva TPS Equipment Container for SmartPole Smart Station and deliv ered accessories part 2 of 2 a b c d e f g h i j 10 RH15 RadioHandle Instrument carry handle GHT63 clamp Cables GDC221 car adapter for CS field controller GAD108 arm GAD110 adapter for GS15 instrument Manuals amp DVD GMP101 mini prism Mini prism spike 1 2 Setting Up the TPS Instrument TPS setup step by step Description Shield the instrument from direct sunlight and avoid uneven