B800-1 Series Frequency Inverter
Contents
1. F 07 Rapid linear Decel time 0 0 to 25s 0 0s s when power cut off Disabled when 0 0s i F 08 Motor rated current Motor rated current 10 to 100 100 F 09 Motor rated frequency to 500Hz 50Hz F 10 Motor output voltage 0 100 of motor rated output 100 voltage F 11 Motor pole pairs 0 1 2 3 4 5 2 F 12 Voltage boost 0 to 28 of max output voltage 8 0 Terminal control 1 kevboard control Fwd only Y control speed 2 kevboard control Fwd Rev Y control speed 3 keyboard control Fwd only Terminal or Keypad Potentiometer control speed F 13 4 keyboard control Fwd Rev 3 control select Potentiometer control speed 5 Reserve Modbus RS485 6 Potentiometer control speed Terminal control Start Stop 7 Y control speed Terminal control Start Stop 8 Terminal control speed Keyboard control Start Stop F 14 Trip log Last four trips stored a only F 15 Extended menu access Code 0 to 3999 0 EXTENDED PARAMETER Menu F 16 Drive Capacity 0 13 Read only 16 B800 Series frequency inverter user manual Voltage 0 OV 10V 1 10V 0V Analog input format ON E V mA B Current 3 4 20mA 4 0 20mA 5 20 4mA F 18 Carrier wave selection KH ae ASKE 2 0 Drive enabled 1 Drive fault or External trip F 19 er 2 At set speed 1 3 motor stop Speed zero 4 Motor at max speed F 01 Multi function termina
2. Parameters have already been set when ex work please don t adjust it casually B800 Series frequency inverter user manual 6 Keyboard Operation 6 1 LCD and operation Key B800 KEYBOARD 6 code Digital 8 8 8 8 8 8 UP KEY ENTER KEY Q 4 RUN KEY Function Key D i POTENTIOMETER STOP KEY wa DOWN KEY 6 2 Utility for operation key When inverter ex work standard parameters are set as default Press Enter key one second then enter into check modify standard parameter group Press or Y key to check the parameter group from F 01 to F 51 Press Enter key again which can read parameter value or Y key modify parameter value Press Press Enter key again Back to parameter group If press Enter key more one second or standby more20 seconds Back to initial status prior to standard parameter group modification If want to enter into extended menu access F 16 F 51 set F 15 to 10 and press Enter key 10 B800 Series frequency inverter user manual 7 Test operation 7 1 Master some relevant functions which may help you acquire more ideal use effects Maximum and minimum output frequency F 01 amp F 02 The maximum and minimum speed limitations are set according to actual individual requirements Acce
3. Make sure inverter is same as you purchase b Make sure inverter is in good condition which don t get damaged during transportation if damaged please don t connect with AC main power c Make sure the S N on warranty is same as inverter Please inform our salesperson ASAP if you find the above problems 3 2 Model explanation BEDFORD B800 2 001 1 B800 1 Series Matched motor h 001 IHP 0 75KW motor Series Voltage Level 2 200 4 400V Brand B800 Series frequency inverter user manual 4 Installation 4 1 Exterior Size 888888 e oo 5 8 u L _ 400V 1 2HP 3 5HP 7 10HP 200V 1 2HP 3 5HP 7 10HP H 165mm 214 255 WwW 120mm 151 180 D 123mm 160 180 4 2 Operating environment To ensure proper performance and long operation life Follow the recommendations below when choosing a location for installing B800 series frequency inverter Make sure the B800 series frequency inverter is protected from the following conditions Ambient temperature hanging type 10 45 C Tank closed type 10 40 C Rain Moisture For enclosed wall mounted type Oil fog salt spray B800 Series frequency inverter user manual Direct sunlight Avoid use outdoors Corrosive gases or liquid Dust or metallic particles in the air Physical shock Vibration Magnetic noise Example welding machine power devices etc High humidity Radioactive materials Combustibles thinner
4. F 39 DC injection braking 0 to 600s 0s time when stop 40 DC injection braking 0 to 600s Os time before start F 41 DC injection select 0 Inactive 0 1 Enabled 42 resistor function 1 2 Enable with overload protect p 43 Frequency instruction to 500 100 adjustment factor F 44 Drive address s comms 0 to 63 1 F 45 Enter Extended menu 0 to 3999 10 access code 0 Parameters can be changed auto save when power cut off Hele Parameteraccess lock 1 Parameter changes not saved 0 When power cut off 2 Read only No changes allowed 18 B800 Series frequency inverter user manual F 47 Hours run meter 0 to 9999 hours us F 48 PID samples cycle 0 1S 400 0S 0 2 F 49 PID proportional factor 0 1 400 0 0 1 F 50 PID integral constant 1 4000 0 integral disable 100 F 51 Analog output gain F 09 1 500 90 Parameter explanation to only read window Parz S icon Monitor content explanation il Default No Range H output frequency HZ L Terminal analog setting frequency HZ P Keypad analog setting frequency HZ F Keypad Up amp Down key setting freq HZ A Drive output current A U Motor Voltage VAC d DC bus voltage VDC t Interior thermal resistor NTC Value 0 1024 n motor rpm display RPM r Motor slip display 19 B800 Series frequency inverter user manual Multi function Contact input menu F
5. voltage 1 Main circuit DC voltage is U Volt Maag voltage one DE lower than detected voltage 2 check power voltage amp wire Brake resistor short 1 Check cable Oen circuit 2 Check braking resistor Overload 1 Check motor loading and OL trp 150 current gt 1 min reduce loading 31 B800 Series frequency inverter user manual Internal power module Pls contact Bedford PS Fit fault Distributor 1 Check heatsink fan 2 Check ambient temperature DERE Heatsinkoverheat 3 Additional space or cooling needed Try again UN FIt Fault source not found If not Pls refer to your BEDFORD distributor IN Flt External input fault Pls check status of terminal 3 EEPROM fault Try again EE Flt Parameters not saved If not Pls refer to your Keep default BEDFORD distributor 10 3 Notice on running Acceleration deceleration Too short ramp time may cause over current gt 150 or rated current which may cause accel decel not to be achieved and or O C fault Overload protection When drive work with full loading current and over current 150 of overloading current gt Imin the drive should occur fault LCD should be twinkling 230 B800 Series frequency inverter user manual 11 BEDFORD B800 1 200V series standard specification BEDFORD B800 1 2001 2002 2003 2005 2007 2010 Voltage lor 39200V 240V 39200V 240V Capacity KW 0 75 15 2
6. would return to initial status if without any operation over 60 seconds Press Enter Key over 1 second we can switch the status between monitor mode and Parameter F 01 when we switch to monitor mode we can use UP and DOWNY Key to read the relevant parameter contents 14 8 The symbol explanation on LCD B800 Series frequency inverter user manual Symbol Symbol on LCD Explanation on LCD Explanation H50 00 Frequency output 50HZ d 300 DC bus voltage 300VDC L50 00 Remote control terminal 345 Interior thermal set frequency 50 00Hz resistor value Keypad i 50 00 ee n1350 RPM 1350 set frequency 50 00 Keypad U d d F50 00 Pro vp down 1 05 Motor slip 1 05Hz key set frequency 50 00 A4 5 Output current 4 5A Stop Drive stop work M ltag U300 D MESI F 01 Parameter F 01 300VAC Radix Point Drive overload P SET Resume default value twinkling 9 Parameter and datasheet 9 Parameter list STANDARD PARAMETER Par Description Range Default F 01 Maximum speed F 02 to 5 F 09 max 500Hz 50Hz F 02 Minimum speed 0 to F 01 max 545Hz 0Hz F 03 Linear Accel time s 0 1 to 3 0005 5s F 04 Linear Decel time s 0 1 to 3 000s 5s 0 2 linear stop ramp stop From a inertia stop coast to stop 9 F 06 V F characteristic 0 Constant torque 15 B800 Series frequency inverter user manual 1 Variable torque
7. 0mA 0 20mA 20 4mA 6 types of standard signals No of V F Patterns Random V F curve Location Indoor protected from corrosive gases and dust Ambient temperature 10 40 C If beyond the allowable degree one degree will derogate 596 output current Storage temperature 40 60 C Environmental 95 without dew gather temperature Vibration 2M S 0 28 Protection rate IP20 B800 Series frequency inverter user manual BEDFORD AC MOTOR SPEED CONTROLLER BEDFORD QUANZHOU ELECTRONIC CO LTD AGENT
8. 2 37 5 5 7 5 Rated output vol V 3 220V 240V Rated output current A 43 70 105 14 19 6 26 6 Control mode Sine wave PWM control Output frequency range Maximum 500Hz Frequency resolution Analog input volume 0 1Hz Overloading capacity Rated output current 150 1 minute 175 2 seconds Analog signal input 0 10V 10 0 10 10V 4 20mA 0 20mA 20 4mA 6 types of standard signals No of V F Patterns Random V F curve Location Indoor protected from corrosive gases and dust Ambient temperature 10 40 C If beyond the allowable degree one degree will derogate 596 output current Storage temperature 40 60 C Environmental 95 without dew gather temperature Vibration 2M S 0 26 Protection rate IP20 0 37kw amp 0 55kw also are available 33 12 BEDFORD B800 1 400V series standard specification BEDFORD B800 1 4001 4002 4003 4005 4007 4010 Voltage 3o 380V 440V Capacity KW 0 75 15 22 3 7 5 5 7 5 Rated output vol V 39 380V 440V Rated output current A 2 2 41 5 8 9 5 13 16 Control mode Sine wave PWM control Output frequency range Maximum 500Hz Frequency resolution Analog input volume 0 1Hz Overloading capacity Rated output current 150 1 minute 175 2 seconds Analog signal input 0 10V 10 0 10 10V 4 2
9. 20 Multi function Multi function Multi function Multi function contact 1 contact 2 contact 3 Contact 4 Open Stop Open Stop Open FA Open NO Close FWD Close REV PUN Ree i Close NO Trip reset E al Open NO Open FWD P st Open Stop Close RUN Close REV Close NO Close NO Open STOP Multi stage Multi stage Multi stage 2 Close RUN speed 1 speed 2 speed 3 Open STOP External Open NO 3 Open FWD trip input Close Close REV Cl NO Close PID Enable Trip reset Open NO Open Stop Open FWD Open External 1 Close Run Close REV trip input Close Trip Close NO reset We define FWD as motor rotary along clockwise direction When F 20 0 which means two wire initialization controlling analog input signal specification can be set through parameter F 17 When F 20 1 which means three wires initialization controlling Terminal 1 is for START Terminal 2 is for FWD REV Terminal 4 is for STOP 20 B800 Series frequency inverter user manual Bem 1 START 2 Go FWDIREV 4 olo STOP 3 Wire system controlling diagram When F 20 2 which means multi stage speed controlling Terminal 1 is for START STOP Preset speed Terminal2 Terminal3 Terminal4 Speed given 1 Speed Open Open Open F 21 2 Speed Close Open Open F 22 3 Speed Open Close Open F 23 4 Speed Close Close Open F 24 5 Speed
10. 4 F 12 F 02 F 33 F 35 F 09 F 01 F 07 Decelerate time when power cut off Linear deceleration time F 05 2 when AC main power cut off Refer to F 20 F 08 motor rated current Motor rated current Drive rated current 10 100 When the capacity of drive is over motor capacity properly adjust Parameter F 08 can avoid motor run with overload F 09 motor rated frequency The rated current value marks on the nameplate of motor if parameter F 09 be changed pls reset parameter F 02 F 33 and F 35 to make sure F 01 gt F 09 gt F 35 gt F 33 gt F 02 23 B800 Series frequency inverter user manual F 10 motor output rated voltage Correspondence output voltage of rated RPM 9 If Parameter F 10 be change pls reset parameter F 36 F 34 F 12 to make sure F 10 gt F 36 gt F 34 gt F 12 Note when the parameters we set do not satisfy with the above relationship drive parameter would be resumed to default value F 11 Motor pole pairs For example Motor rated frequency is 50HZ RPM range can be set from 600 3000RPM min When F 1120 LCD show the speed with RPM unit otherwises LCD display 0 F 12 Low speed voltage compensation boost Application of compensation function make frequency inverter get adjustment compensation when low speed runs thus ensure the motor start steadily F 13 Terminal or keyboard controlling select controlling mode Set motor Start Stop controlling via termi
11. B800 Series frequency inverter user manual BEDFORD AC MOTOR SPEED CONTROLLER B800 1 Series Frequency Inverter BEDFORD QUANZHOU ELECTRONIC CO LTD B800 Series frequency inverter user manual Category 1 Preface 2 Notes for safe operation 3 Inspection checkpoints 3 1 Check POC CIE us eam preci Ptr 4 3 2 Model EXDISBRAD Ou us eee tici vorrei EY Ote duci pa ips Gt 4 4 Installation TRIERER dig Ede dea Rete Hd ak edt 3 4 2 Operating environment 4 3 Notice 5 Wiring 5 1 Connection diagram 5 2 Notes for operation 6 Keyboard Operation 6 1 LCD and operation key sinin e e a a atis 9 6 2 Utility of operation key 7 Test run operation 7 1 Master some relevant functions which may let you acquire more ideal use effects 7 2 Keyboard operation mode j 7 3 Keyboard operation for FOR REV see 11 7 4 Terminal control mode 7 5 Parameter resume ex work value 7 6 Saving condition after parameter modification 8 The symbol explanation on LCD 9 Parameter and data sheet 9 1 Parameter list 9 2 Parameter explanation 10 Fault diagnosis and corrective actions 10 1 Notes for remedy once fault detects sss 28 10 2 TroubleshoOUBg u ua 10 3 Notes during operation 11 BEDFORD B800 1 200V series standard specification T 12 BEDFORD B800 1 400V series standard s
12. Open Open Close F 25 6 Speed Close Open Close F 26 7 Speed Open Close Close F 27 an Speed Close Close Close F 28 When F 20 3 Contact terminal 1 is for PID control Feedback value input from terminal 6 and terminal 5 Target value is set from the keypad When F 20 4 if F 13 1 2 3 4 Keypad controlling mode FWD REV is controlled by terminal 2 Keypad control Start Stop amp control speed 22 x B800 Series frequency inverter user manual 9 2 Parameter explanation Standard parameter group F 01 max output frequency Maximum frequency limitation Speed refer to F 10 Kouenbaj ndino F 02 min output frequency Minimum frequency limitation F 02 Speed refer to F 10 Frequency reference set 9 F 03 linear Accel time S The required time accelerate from 0 to max speed F 04 linear Decel time S The required time decelerate from max speed to 0 F 05 stop mode select 0 Decelerate and stop according to parameter F 04 2 Decelerate and stop according to parameter F 07 1 Get Stop instruction Drive stop output motor coast to stop inertially F 06 V F characteristic curve select A Relation between voltage and frequency Pls refer to picture 0 curve is constant torque curve is variable torque B Through adjust the parameter F 33 F 34 F 35 F 36 V F curve can be further changed as below picture aTa B800 Series frequency inverter user manual F 36 F 3
13. amp to stop F 39 sets the duration of DC braking applied when the ramp reaches zero F 40 DC injection braking time before start F 41 DC injection function As F 41 1 if drive is on working the DC injection functions enable and will execute according to parameter F 39 amp F 40 F 42 Braking resistor function select Activate interior brake resistor When F 42 1 Brake resistor functions enable When F 4222 Should be overload protection to avoid resistor and drive damaged F 43 Frequency instruction adjustment factor Scales the analog input at control terminal 6 up or down Appear the correspondence analog input value according to parameter F 09 F 44 Communication address Drive address means order invalid F 45 Enter Extended menu access code Define the password for Extended menu access F 15 F 46 Parameter access lock Controls user access to parameters When F 46 0 all parameters can be changed and these changes will be stored automatically When When F 46 1 changes may be made but these will not be stored when 29 B800 Series frequency inverter user manual the drive power cut off When P 46 2 Parameters are locked and cannot be changed thus preventing unauthorized access F 47 Accumulation running time Hours run meter Read only F 48 PID control samples cycle F 49 PID control proportional factor F 50 PID control integral constant When F 20 3 Drive output frequency is decided by PID c
14. as external frequency given signal 25 B800 Series frequency inverter user manual When analog input is current signal pls put the SC socket on left side CPU board Pls refer to Page 8 connection diagram If bipolar signal set as 10 10V frequency inverter run FWD REV is controlled by polarity signal F 18 Carrier wave frequency selection Effective power stage switching frequency inverter Improvements in acoustic noise and output current waveform occur with increasing switching frequency at the expense of increased losses within the drive 0 2 KHz 1 4 KHz 2 8 KHz 3 12 KHz 4 15KHz F 19 Multi function contact output selection Relay contact output function indicate the working status of drive F 20 Multi functions contact input selection Multi functions terminal 1 2 3 and 4 correspondence common terminals to effect ON OFF functions the definition please refer to F 20 multi functions contact input menu F 21 F 28 multi stages speed 1 8 Refer to multi functions contact input F 20 Preset multi speed 1 8 according to actual running requirement F 29 Slip compensation Slip modification factor whose numerical definition is applied as interior calculation for slip compensation percentage 26 B800 Series frequency inverter user manual F 30 Analog output functions The terminal 8 9 is the multi function analog output terminal As F 30 0 output 10V F 01 100 correspondence actual output frequen
15. cy As F 30 1 output 5V F 08 100 Correspondence motor currents As F 30 2 Give a 10V digital output As F 3023 output 10V F 01 100 correspondence set frequency 100 Hz A 400 F 30 0 3 0 10 5V Output F 30 2 oV F 31 Skip frequency speed Skip frequency center controlling points are defined by F 31 when the frequency is negative F 32 appear to 0 HZ andino F 31 1 Frequency reference 7 B800 Series frequency inverter user manual F 32 skip frequency speed band The center is defined by F 31 F 33 V F Characteristic Curve Mid Frequency 1 Pls refer to V F curve picture F 34 V F Characteristic Curve Mid Frequency 1 Correspondence output voltage Pls refer to V F curve picture F 35 V F Characteristic Curve Mid Frequency 2 Pls refer to V F curve picture F 36 V F Characteristic Curve Mid Frequency 2 Correspondence output voltage Pls refer to V F curve picture F 37 Starting mode A When F 37 1 If terminal 1 amp 5 is ON before electrify drive can not be started Pls put the terminal 1 amp 5 OFF first and then put terminal 1 amp 5 ON the motor start B When F 37 0 Drive will run when terminal 1 amp 5 ON F 38 DC injection voltage If F 05 selection is ramp to stop F 38 sets the level of DC braking applied when the ramp reach zero F 39 DC injection braking time 28 B800 Series frequency inverter user manual If F 05 selection is r
16. he motor rotary When Start Off switcher OFF or turn potentiometer to 0 Inverter stop work When F 20 1 means three wire initialization controlling Terminal 1 stand for Start Switcher Terminal 2 stand for For Rev switcher Terminal 4 stand for Stop switcher 7 5 Parameters resume default Parameters reset When inverter stop and appear Stop on LCD simultaneity press OF Y and Enter Key 1 second LCD appears P SET which means all parameters have resumed to default ex work value Press Enter Key again LCD appears Stop Parameter F 45 would restore to 10 but F 47 and F 14 not be effected x3 B800 Series frequency inverter user manual 7 6 The saving condition after parameter modification As F 46 0 Default value all parameters could be modified and they would be saved in EEPROM when AC main power is cut off As F 46 1 all parameters could be modified but they would not be saved in when AC main power is cut off As F 46 2 all parameters couldn t be modified read only Notice To prevent other persons modify parameters causally please select any number among 0 to 3999 for parameters F 45 enter into Extended menu access password Under status of Extended menu access monitor LCD would return to initial status if without any operation within 20 seconds when enter into the status of monitor LCD
17. l O to 4 F 20 input selection 0 F 21 Multi stage speed 1 F 01 reverse to F Ol Forward 50Hz F 22 Multi stage speed 2 F 01 reverse to F Ol Forward OHz F 23 Multi stage speed 3 F 01 reverse to F Ol Forward OHz F 24 Multi stage speed 4 F 01 reverse to F Ol Forward OHz F 25 Multi stage speed 5 F 01 reverse to F Ol Forward OHz F 26 Multi stage speed 6 F 01 reverse to F Ol Forward OHz F 27 Multi stage speed 7 F 01 reverse to F Ol Forward OHz F 28 Multi stage speed 8 F 01 reverse to F Ol Forward OHz F 29 Slip compensation 096 to 11096 of rated Slip 096 0 Motor Speed F 30 Analog output function 0 2 Drive enabled 3 Set speed F 31 Skip freq speed 0 to F 01 max 0Hz F 32 Skip freq speed band 0 100 F 09 0Hz V F characteristic curve 0 to F 09 pom Mid Frequency 1 0Hz disable nm 17 B800 Series frequency inverter user manual V F characteristic curve F 34 Mid Frequency 1 0 100 29 correspondent voltage V F characteristic curve 0 to F 09 En Mid Frequency 2 0Hz disable SB V F characteristic curve F 36 Mid Frequency 2 0 100 42 correspondent voltage 0 Start when terminal ON 1 If termnal is under ON status F 37 Drive start mode before electrify inverter can not 1 be started Pls put the terminal OFF first and then ON the motor start F 38 DC injection voltage 0 1 to 2296 of max voltage 16
18. lerate and decelerate parameter F 03 amp F 04 If linear acceleration time and linear deceleration time too short on some occasions which may cause drive over current and let drive trip which cause motor stop working Stop mode F 05 When F 05 0 inverter would diminish motor s speed according to linear deceleration time we set If F 02720 when inverter start motor would accelerate from mini frequency we set F 02 when inverter stops work the motor linear decelerate to 0 and then stop work If user want the motor stops work automatically inertia stopping please sets F 05 to 1 V F curve select F 06 General loading F 06 0 Such as fan water pump etc which are belonging to variable torque loading Set F 06 1 which will reduce the energy wastage when motor run at low speed Motor rated current rated frequency and rated RPM F 08 F 09 F 10 Parameters should be set according to the nameplate on the motor Low speed voltage compensation F 12 Favorable to start motor smoothly Maximum value of voltage compensation up to 28 Controlling methods select F 13 Terminal controlling method is for long distance control use 11 B800 Series frequency inverter user manual Keyboard controlling method is for trial running or handle manually Extended menu access select F 16 F 51 Extended menu access is designed for inverter application experts engineers or technicians General users don t need to u
19. lose loop controller PID parameter can be set via Up and Down Y key on the keypad Full range value is equal to value of F 01 For example If F 01 50 the full range is 50 00 Unit PID is decided according to physical circumstance If PID set value is for water pressure 10 00 should be regarded as 10 00Mpa The feedback of PID controller input from Terminal 6 Analog input format amp type is decided by F 17 amp F 43 F 51 Analog output gain Output 10V F 51 F 09 100 HZ 30 B800 Series frequency inverter user manual 10 Fault diagnosis and corrective actions 10 1 Notes for remedy once fault detects f want to eliminate abnormity must clean up the abnormity conditions and withdraw controlling terminal order then press 97 STOP key to reset drive would start automatically re start automatically according to parameter F 37 eIf motor stop and inverter appear Stop which mean drive is non abnormity it s under standby 10 2 TROUBLESHOOTING Fault What has happened What to do Code Default parameters Press STOP key t P SET acknowledge and enter loaded parameter values Over current on drive 1 Check motor coil resistance O C output 2 Extend the accel decal time Drive output current 3 Check motor insulation exceed OC level 4 Multi meter check Extend the deceleration time O Volt Over voltage on DC bus 2 Fit braking eg braking resistor 3 Check input
20. nal or keypad Set frequency reference controlling via terminal or keypad When F 1320 both Start Stop and frequency reference come from terminal controlling Pls refer to F 20 When F 13 2 Control speed via UP or DOWN Y Press Run Key to achieve FWD REV functions Press STOP Key and then Press Run Key 1 Drive start to make motor still run as FWD direction 24 B800 Series frequency inverter user manual When F 13 4 Control speed via the potentiometer on the keypad Press Run Key to start motor and achieve FWD REV function When F 13 6 Control speed via the potentiometer on the keypad Control START STOP via terminal controlling If F 20 0 means two wire system controlling If F 20 1 means three wire system controlling If F 20 2 3 4 Parameter disable When F 13 8 Control speed via terminal Control Start Stop via keypad F 14 Trip log record The previous 4 trips records can be stored according time in sequence the earliest appearance record is recent trip record Press or T key 4 records are alternative F 15 Enter extended menu access menu Input default 10 to enter into extended menu access this default can be modified through parameter F 45 Forbid non authorization entering into Expansion Menu access Expansion parameter group F 16 Drive capacity Read only Input analog voltage current signal through terminal 6 which be regarded
21. pecification B800 Series frequency inverter user manual l Preface Thanks for your choose BEDFORD B800 series high functional frequency inverter please read this manual carefully before use 2 Notes for safe operation Frequency inverter is a latest product for electric and electronic To guard your safety there are signals both danger and notice in this manual to remind you some safety precaution notices when movement installation operation and check ANGER Misuse may cause casualty NOTICE Misuse may cause damage to inverter or system O DANGER Please don t take down alter Otherwise it may cause electric shock fire and injure Don t open the cover during electrify Don t put or insert wire stick and filament etc into inverter to avoid short circuit or electric shock Please don t splash water or other liquid onto inverter A NOTICE Please don t perform a withstand voltage testing to the components of inverter Absolutely don t connect output terminal U V W with AC main circuit power supply Components CMOS IC on circuit board are easily affected and damaged by static electricity please don t touch it casually Electromotor and inverter should fit to the matched AC power Otherwise it may cause operate abnormality even burn B800 Series frequency inverter user manual 3 Inspection checkpoints 3 1 Check procedure a
22. r 240V4C 1A FWD STOP REV STOP Multi function EXTERNAL Fault input BM Fault Reset Multi function analog output Master Frequency Reference 0 10V 4 20m amp 2 2K 10KQ Voltage signal input Current signal input Note 1 three phases 380V use R L S N T as AC main power input terminal Single phase 220V only uses R L and S N 2 Braking resistors of single phase 220 1 2 amp three phase 380 1 2hp are all inbuilt 8 B800 Series frequency inverter user manual 3 B800 Series inverter default as keyboard control F 13 1 it will work after AC main power input 4 Default value between terminal 5 amp 6 is analog voltage signal input short circuit socket put on the right side when the analog signal input is current signal Pls put the short circuit socket on the left side 5 2 Notes for operation Parameter F 01 can be set as Max 30000 rpm Min of motor please use this parameter with care If user wants to operate the RPM of motor higher F 09 F 09 parameter than the rated rotate speed of motor please confirm the allowable range between the motor and machinery The cooling fan of inverter would automatically start to work once the temperature reach 40 C and would stop working when its temperature is under indoor Please attention other relevant settings once use braking resistor Please don t check the signal on PCB when inverter is running
23. s solvents etc If few inverters are mounted into cabinet Please kindly put them on ventilated position where the good ventilation is available Further to mount the cooling fan inside the cabinet to make the ambient environment under 45 C Sufficient mounting space within below stipulation 30mm 30mm gt gt Ee es gt 150mm T A Outer temperature p lt 45 C 888888 Inside temperature Hanging type Doe 10 45 C gt 99eooo Front cov r j d Tank closed type 10 40c 150mm Air a Front View b Side View B800 Series frequency inverter user manual 4 3 Notice A Notice Please don t hold the front cover when move the right way is to hold the heatsink of inverter so as to avoid falling down which could injury person or damage inverter itself Please mount inverter onto nonflammable materials like metal and other else please don t mount it nearby nonflammable materials to avoid fire If few inverters are mounted into a controlling cabinet cooling fan must be mounted inside cabinet to ensure temperature of cabinet inside is lower than 45 C to avoid overheat Please cut off AC main power prior to remove keyboard B800 Series frequency inverter user manual 5 Wire 5 1 Connection diagram Braking Resistor Multi function output pu
24. se it 7 2 Keyboard operation mode Press Run Key U LCD appear to H0 0 Press UP Key w frequency output increase Press DOWN Key Y frequency output descends Press STOP Key 9 inverter stop frequency output LCD appears to stop 7 3 Forward Reverse operation on Keyboard Set F 13 2 Press RUN Key LCD appears to H0 0 Press key Speed increase Press RUN Key again Change motor rotary direction Set Parameter F 13 3 Press RUN Key LCD appears to H e Turn the potentiometer as clockwise to increase speed Turn the potentiometer as anti clockwise to descend speed Set Parameter F 13 4 Press RUN Key L LCD appears to H e Turn the potentiometer as clockwise to increase speed Turn the potentiometer as anti clockwise to descend speed B800 Series frequency inverter user manual Press RUN Key again Change motor rotary direction 7 4 Terminal controlling operation mode Parameter F 13 0 Control terminal operation mode Connect the start stop switcher among terminal 1 2 and 5 Connect one potentiometer 2 2KQ 10KQ among terminal 5 6 and 7 When F 20 0 means two wire initialization controlling Terminal 1 2 stand for Forward Start Off switcher and Reverse Start Off switcher respectively When Start Off switcher ON Turn potentiometer to change output frequency HZ to make t
Download Pdf Manuals
Related Search
Related Contents
MANUAL DE INICIAÇÃO RÁPIDA Remote Control DEMO KIT User's Guide 取扱説明書 Grade 3 Teacher Section QuIckcheck Math: uSeR guIde Piano di sicurezza e coordinamento 迪まずはご自分でできる点検を・・・ DORAN INTERNATIONAL Nero Vision - ftp.nero.com CREsTO 1141 CREsTO 1142 CREsTO 1143 CREsTO 1144 Copyright © All rights reserved.