Contents
1. National Fire Protection Association 2 Underwriters Laboratories Inc 3 this standard 4 other reference documents 3 Conventions and Definitions 3 1 Conventions 3 1 1 Units of Measurement In accordance with SIA Policy the units of measurements used throughout this publication are the units of the System International d Unites SI commonly known as metric units Equivalent English Units enclosed in parenthesis are also used in this publication These equivalent English Units are approximate conversions and are provided for easy reference 3 1 2 Tolerances Unless otherwise specified the tolerance for measurements specified within this standard shall be 10 percent 10 3 1 3 Special Capitalization Alarm sequence events alarm system commands and states and digital communication codes transmitted by the control panel to the central station are capitalized within the text of this standard Page 2 O SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 3 1 4 Nomenclature and Identification of Clauses Clauses and subclauses within this standard are identified and referenced by the number preceding each clause Unless otherwise specified references to a clause refer to only that clause and not to subsequent subclauses within the clause 3 1 5 Binding Language This standard uses the term shall to convey binding requirements The term may is used to convey features that a
2. 0 75V 0 120 ohms total loop resistance o loop normal 1 1V 4 1V 190 3000 ohms o loop open 4 6V 5 0V 7800 infinite ohms When a panel has more than one type of zone input a specification may be required for each type SIA 2000 2009 All rights reserved Page 49 1 2 2 4 5 5 5 6 6 9 11 2007 minutes 4 3 4 Revision Items for CP 01 2009 Draft from meeting records since Septebmer 2007 lightning and thunder date document paragraph topic source status details __k 4 2 2008 10 29 2008 minutes 4 3 4 lightning and thunder Frank Clark ac fests once minutes 4 3 4 ADT Bill Mood ADT Bill Moody discussed Frank to draft lightning and thunder meeting results were inconclusive lightning and thunder 9 11 2007 minutes 4 2 7 single button remote 9 11 2007 minutes 4 2 7 single button remote 4 2 2008 3 9 2009 minutes editing 4 2 7 4 2 7 pe ansees single button remote discussed alarm devices finalized at this meeting TN fadded I single button remote single button remote 9 11 2007 minutes 4111 independent partitions ADT discussing _______ 4 2 2008 10 29 2008 minutes 4 1 1 independent partitions 3 9 2009 minutes editing 4 1 1 4 1 1 independent partitions ftorevised _ to working group read to add independent partitions added 2 17 2009 email 4 1 1 independent partitions ADT confirmed email confirming
3. SYSTEM STATE ANNUNCIATOR Armed LOCAL ALARM COMMUNICATION Violation of an instant zone Page 26 Abort Window Alarm Annunciation Sounds until alarm time out 30 Alarm Transmission Transmit Alarm O SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 Annex D informative Recommended Self Validation Procedures The following procedures are intended to ascertain compliance with the requirements of the Security Industry Association s Control Panel Standard Features for False Alarm Reduction These procedures are intended for use by the manufacturer to validate their design and for use by UL or other nationally recognized testing laboratories NRTL to confirm compliance Although a control panel can be validated as a stand alone unit these procedures are written for a system test where various peripherals sensors annunciators etc are used with a control panel They refer to the control panel being tested including its arming stations as the Unit Under Test UUT These procedures are organized by the clauses of their associated requirements in the standard to provide convenient reference but they are not intended to suggest the sequence of testing While all features should be tested it is understood that individual product implementations will dictate optimum sequencing of tests These procedures assume that unless otherwise specified e all programmable options
4. Arm the UUT Verify that the time between the last arming keystroke and a Full Arm Exit Time is 60 seconds Disarm the UUT Program the Exit Time to 44 seconds and verify that the Exit Time is 45 seconds or greater Note If the UUT did not accept programming to 44 seconds proceed to the next test Program the Exit Time to 45 seconds and verify that the Exit Time is 45 seconds Program the Exit Time to 120 seconds and verify that the Exit Time is 120 seconds Program the Exit Time to 256 seconds and verify that the Exit Time is 255 seconds or less Note If the UUT did not accept programming to 256 seconds proceed to the next test Return the UUT to the default Exit Time setting Arm the UUT Trip an entry exit zone Verify that the time between the last arming keystroke and the local alarm is 60 seconds Disarm the UUT If the UUT has a silent exit feature e Arm the UUT with the silent feature and verify that the Exit Time is 120 seconds Arm the UUT normally and verify that the Exit Time is 60 seconds EOT Page 28 SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 VALIDATION PROCEDURE VP 3 Progress Annunciation Arm the UUT Verify that Exit Time is annunciated Verify that the annunciation changes during the last 10 seconds of the Exit Time after 50 seconds of Exit Time If the UUT has a silent exit feature Arm the UUT with the silent feature Verify that
5. Informative Clarifications and Interpretations incorporated into the body of the document with the exception of 4 7 Default settings which was removed New Annex G Informative added for New Central Station Signals New Annex H Informative added for Common Nomenclature New Annex F Informative added for Clarifications for Effectivity New Annex Informative added for System Configuration Identification New Annex J Informative added for Labelling REVISION 3 2 2 add or other types of life safety initiating devices 3 2 9 add manually 3 2 19 add authoritative only authorized and the ability 3 2 24 shortened and clarified 3 2 30 added helps 3 2 31 shortened and revised the definition removed carbon monoxide 3 2 44 shortened and revised the definition 3 2 58 add or remote station 3 2 63 add of the security system 3 2 66 new definition for zone type 4 1 1 added section regarding independent partitions 4 2 2 4 changed E E to entry exit added message to the remote station 4 2 4 1 add helps 4 2 7 excluded single buttons which must be held to initiate alarms Page xii SIA 2000 2009 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 e 4 6 1 clarify documentation requirements throughout section add specific user manual requirements e 4 6 7 1 add audible e Annex D add or other nationally recognized testing laboratories e 4
6. JANUARY 2000 REVISION Substantive Change 4 2 5 1 Abort Window Change the line in the programming range chart from Maximum 30 255 sec to Maximum 45 sec Non Substantive Change 3 2 Definition of Duress Add the following phrase after a facility or commit some other act or action against the individual s will 3 2 Definition of Zone Type Change to zone type a zone or group of zones identified by common function or operating mode 4 2 4 1 Description of Control Buttons add after Remote control device buttons including Duress Holdup and Panic shall be mechanically designed be minimized 4 2 5 1 2 Abort Window Add a note that an abort signal may be sent Page viii SIA 2000 2009 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 4 6 1 Add a note to Quick Reference that user manuals should contain the following statement or one similar There is a communicator delay of 30 seconds in this control panel It can be removed or it can be increased up to 45 seconds at the option of the end user by consulting with the installer Appendix A 4 2 5 1 Changed range from 15 sec 30 sec 255 sec max to 15 sec 45 sec Appendix B 4 2 5 1 Changed from 15 to between 30 and 255 seconds to 15 to 45 seconds Appendix D Test Procedures 4 2 5 1 Changed maximum Abort Window delay from 255 sec to 45 sec Changed verification parameters from time be
7. 4 2 2 4 DS foada MN f dded IOS foad TN fadded audible audible remote station remote station 2 12 2009 email 4 3 2 swinger shutdown ADT jimput 2 12 2009 editing 4 3 2 swinger shutdown TN dadded ___________
8. Procedures may include the entry of a user code without additional keys or the presentation of a credential Systems may implement one or both of these procedures Alternative disarming methods may co exist Also added When systems require entry of a user code alarm annunciation at the keypad shall be silenced upon entry of the first digit of the user code Alarm annunciation shall resume upon entry of an invalid user code or after a manufacturer specified time during the Abort Window e 4 2 5 4 1 Cancel added Some panels may require a special function key after Disarm to send a Cancel signal Also added An option may be provided to delay the Cancel signal and other non alarm signals until after termination of active two way voice sessions in the instance that the end user initiates a cancel sequence while a two way voice session is already in progress Page x SIA 2000 2009 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 e 4 3 1 Cross Zoning last bullet added An option may be provided to delay the Cancel signal and other non alarm signals until after termination of active two way voice sessions in the instance that the end user initiates a cancel sequence while a two way voice session is already in progress e 4 3 2 Swinger Shut Down added Note NOTE Zones disabled by swinger shutdown shall not transmit restoral signals until they are returned to service e 4 4 2 Labelling refined
9. SIA 2000 2009 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 A EE John Murphy Fe Fe Matthew Kenjura A ER Dale Berti Yale Commercial Locks and Hardware enannvnnannvnnonvnnnnrrnarrnnnnrnnnnvnnnnnennnnn Reid Wilson This standard was developed by the SIA Standards Security Control Panels Subcommittee SIA gratefully acknowledges the efforts of the many volunteers listed below from the security industry that helped the Subcommittee to develop this standard SIA Standards Security Control Panels Subcommittee Chair Se TE ean Ted Nesse ERR EE sommes T A sand Larry Dischert FLAT OPA eo John Favia A sai der AE E E E Bernie Worst ILE Vash E E E E E E A E E Bill Moody JE ERR EE E E Jimmy Salinas 2 dasehidyietaetccucietaadeniiycadaiaetceeiive Shane Cleary SP ERE ER EN Rick Sheets IRER EE Sanna cease E cet E T Kevin Harris HERR RER EE TE David Roberts HER NE TE Terry Shelton PP na Mark Mills Ek Produtis Mesa Donald Lamb Ek Froducis NE David Steele Es N dertaatan eda aati oper Materuaiager Frank Clark EE correc ree tere terre ee A per eer tree ra E Bill DeVoe ER NE ES Rich Hinkson EEE aaa Robert Orlando O Scott Simon en anida Tom Connaughton MAS A A George Bish NAPO O soni Michael Carrieri Numerex GOPUPpINk SOU conca rd nie unde salen Richard Ader PICON POCO ONO Tim Stacey RR RE AN Dan O Malley PONG A en UU o A Bob McKee Phoenix Police Departmen cnisnada a knna Patti Rae Phoenix Police Depa cion Rebecca
10. VP 25 Fire Alarms 4 3 3 Verify that Verification may be disabled e Program the UUT to disable Fire Alarm Verification e Trip a sensor on a fire zone e Verify that the UUT transmits an alarm signal With Verification enabled test that a single trip does not cause an alarm e Program the UUT to enable fire alarm verification e Trip a sensor on a fire zone that has been configured for alarm verification e For UUTs with a means for determining that a zone has been reset verify that the UUT resets the zone For self resetting sensors remove the tripping means after 5 seconds e Verify that no alarm is triggered within the time frame designated by the manufacturer Check that multiple trips on a sensor do trigger an alarm e Wait for a period of 3 minutes to allow the confirmation period to time out e Trip a sensor on a fire zone that has been configured for alarm verification e For a UUT with a means for determining that a zone has been reset verify that the UUT resets the zone When the zone is reset trip is again within the time frame designated by the manufacturer For self resetting sensors remove the tripping means 5 seconds after the sensor trips Wait 15 seconds then re apply the tripping means and hold it e Verify that an alarm signal is transmitted after the second trip within the time frame designated by the manufacturer Check that a sustained trip on a sensor does trigger an alarm e Reset the fire alarm system of th
11. a default identification number assigned to a security system for quick Arming of the system 3 2 63 violated a condition at the premises detected by a sensor that causes a trip of the security system Page 8 SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 3 2 64 zone a dedicated input to the control panel containing one or more sensor devices which will trip that input upon activation of any one sensor device 3 2 65 Zone in Error the zone that has produced an erroneous alarm condition 3 2 66 zone type an identifier for a set of attributes that define how a zone will respond to various changes in its inputs An example of an attribute is the response to a short when the system is in a disarmed state Examples of zone types are Fire Interior Burglary Perimeter Burglary etc 4 Requirements 4 1 Partitioned Systems Partitioned systems shall provide the requirements of Clause 4 2 User Caused False Alarms 4 3 Sensor Caused False Alarms and 4 6 Installation and Test for each partition Each partition needs to be able to support the requirements in Clause 4 In testing it will be acceptable to test 2 partitions as indicative of the product s ability to meet the requirements in all partitions When silent exit is used in a partitioned system it shall meet the same requirements as for non partitioned systems 4 1 1 Independent Partitions Option If the system user operates a partitioned syst
12. a zone or circuit equipped with sensors designed to detect a fire condition e g smoke heat etc 3 2 32 follower zone a non entry exit zone typically an interior zone located on an entry exit path that is treated as an entry exit zone during an Entry Delay or Exit Time 3 2 33 Full Arm an armed state of a security system where all zones and sensors are activated 3 2 34 Holdup the presence of one or more criminals attempting to take goods or funds with implied or actual threat of force 3 2 35 Home see Stay Arm 3 2 36 instant zone a non 24 hour zone that causes an alarm immediately upon being tripped 3 2 37 key fob a type of remote control device 3 2 38 keypad see arming station 3 2 39 local alarm an alarm indication given at the protected premises by activation of a sounder 3 2 40 manual reset the act of clearing an alarm condition in a security system by human intervention either at an arming station or by remote control Page 6 SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 3 2 41 Open the act of Disarming a security system 3 2 42 operating code a numeric sequence used to control the alarm system usually entered manually at a keypad 3 2 43 option a functional or performance feature that is required by this standard but may be implemented as a selectable part of a product s performance capability 3 2 44 Panic a general type of alarm initiated
13. added If multiple keypads are annunciating the entry delay one or more keypads may be momentarily silenced e 4 2 4 1 Control Buttons added The requirements applied for all control buttons are not the same those as for manual alarms see section 4 2 4 2 Control buttons only need to implement the mechanical design features to prevent inadvertant activation not the dual action requirements of section 4 2 4 2 For testing the manufacturer may need to provide in their product literature or otherwise rationale on their mechanical design and how it minimizes inadvertent activation e 4 2 4 2 Manual Alarms added Testing to comply with Manufacturers specification e 4 2 4 3 System Acknowledgement added Acknowledgment of Arm and Disarm may or may not be unique A manufacturer may use the same acknowledgement for both functions if separate buttons are used for Arming and Disarming e 4 2 4 4 refinements for Remote Control Device e 4 2 4 5 Remote Disarming added e 4 2 5 1 Abort Window clarified to The abort window may be disabled for each zone or zone type individually for the entire system The default setting for the Abort Window shall be that it is enabled for all non fire zones and zone types It shall not be possible to globally disable the abort window using a single system wide option e 4 2 5 1 1 Disarm added When the system is in an alarm condition the system shall Disarm by a single step procedure
14. an Entry Exit Zone is not violated prior to disarming the system the progress annunciation described in clause 4 2 3 1 through 4 2 3 3 will not start 4 2 5 Alarm Transmission Sequence To reduce the incidence of false alarms during alarm transmissions the following sequence of events shall be required Page 12 SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 4 2 5 1 Abort Window A programmable Abort Window shall be included for all non fire zones During an Abort Window the local alarm shall sound and the annunciator shall annunciate an alarm The minimum time given is an absolute minimum and panels shall not allow an Abort Window of less than 15 seconds NFPA requirements shall be met when the Abort Window is applied to any fire zone The abort window may be disabled for each zone or zone type individually for the entire system The default setting for the Abort Window shall be that it is enabled for all non fire zones and zone types It shall not be possible to globally disable the abort window using a single system wide option The programming for the Abort Window for all non fire zones shall be as follows SIA 2000 2009 All rights reserved Page 13 ANSI SIA CP 01 2007 Table 1 Programming for the Abort Window for all Non Fire Zones Programming Range Default Time NOTE In accordance with UL standards this standard intends that the aggregate of the Entry Delay and Abort Win
15. control devices i e key fobs can also give the user a means of remotely initiating manual alarms SIA 2000 2009 All rights reserved Page 7 ANSI SIA CP 01 2007 3 2 52 secondary power power provided from a secondary source such as a battery or generator upon the loss of primary power 3 2 53 silent exit a user initiated feature that silences the audible progress annunciation of the exit delay 3 2 54 siren a type of sounder 3 2 55 sounder a high level audio device whose purpose is to alert person s at the protected premises of an alarm condition 3 2 56 Stay Arm an armed state of a security system where some zones or sensors are active while other zones or sensors are made inactive allowing occupants to be inside the protected premises without causing an alarm 3 2 57 swinger shutdown an operating mode in which the control panel when a sensor or zone is repeatedly tripping ignores the trips on that zone after a limited number of them 3 2 58 transmission an electronic message sent from the control panel to the central station or remote station 3 2 59 trip an alarm state of the security system produced as a result of detection by a sensor 3 2 60 user code the numeric sequence of digits that correlates to a valid user number 3 2 61 user interface see arming station 3 2 62 user number an identification number assigned to a person who operates or has access to the security system or
16. see section 4 2 4 2 Control buttons arm disarm etc only need to implement the mechanical design features to prevent inadvertent activation not the dual action requirements of section 4 2 4 2 For testing the manufacturer may need to provide in their product literature or otherwise rationale on their mechanical design and how it helps minimize inadvertent activation 4 2 4 2 Manual Alarms The requirements of clause 4 2 7 Initiation of Manual Alarms shall be met when activating manual alarms by remote control devices Testing to comply with Manufacturers specification 4 2 4 3 System Acknowledgment The control panel shall provide acknowledgment of Arm and Disarm commands from the remote control device such that the acknowledgment can be discerned from the exterior of the premises Acknowledgment of Arm and Disarm may or may not be unique A manufacturer may use the same acknowledgement for both functions if separate buttons are used for Arming and Disarming 4 2 4 4 Remote Arming When the system is Armed using a remote control device the control panel may be programmed to Arm the system without an Exit Time and the associated progress annunciation as described in clause 4 2 2 1 Exit Time through 4 2 2 6 Recent Closing The default configuration for the control panel shall be to Arm the system using the Exit Time and progress annunciation 4 2 4 5 Remote Disarming When the system is Disarmed using a remote control device such that
17. the requirements of clause 4 6 4 2 Initiation Report A feature may be provided to transmit test signals The default setting for this feature if provided shall be disabled 4 6 6 Test in Progress During a test the control panel shall give a clear prominent and continuous indication that the system is being tested This indication shall be made at all wired system arming stations 4 6 7 Termination of Test 4 6 7 1 Automatic Termination When a panel automatically terminates a test the panel shall annunciate an audible warning different from the annunciation specified in clause 4 6 6 Test in Progress beginning five 5 minutes prior to the termination of the test SIA 2000 2009 All rights reserved Page 19 ANSI SIA CP 01 2007 4 6 7 2 State at Termination Termination of a test shall leave the security system in a disarmed state 24 hour alarm zones are exempt from this requirement Should a point in a 24 hour alarm zone be in violation at the termination of a test the panel shall suppress the alarm and treat the zone as a trouble condition The standard does not prohibit the annunciation and or the reporting of fire alarm trouble during a test mode 4 6 7 3 Termination Report When a test is terminated the control panel shall send a message to the central station that the test is over 4 7 Default Settings All features of this standard implemented as selectable options shall be selected as the factory default ex
18. verify that the UUT does not enter the test mode e Disarm the UUT e Start a test sequence and verify that the UUT sends a transmission that a test is in progress When the user number is available verify that it is included in the message EOT VP 33 Communications e Ifthe UUT can be programmed to transmit information regarding system tests verify that the setting for this feature is defaulted to disable test communications e Start a test sequence e Trip a zone and verify that the UUT does not send any transmission EOT VP 34 Test in Progress e Start a test sequence e Verify that indication of a test in progress is present at all wired system arming stations EOT TERMINATION OF TEST VP 35 Automatic Termination If the UUT supports automatic termination of test e Start a test sequence e Cause the UUT to automatically terminate the test Refer to manufacturer s instructions e Verify that the UUT provides annunciation of an impending test termination at all wired arming stations beginning 5 minutes prior to the termination of the test e Verify that the annunciation is different than that given during the test in progress EOT SIA 2000 2009 All rights reserved ANSI SIA CP 01 2009 rca 4 6 1 4 6 2 amp 4 6 3 4 6 4 1 amp 4 6 4 2 4 6 5 4 6 6 4 6 7 1 Page 41 ANSI SIA CP 01 2007 VALIDATION PROCEDURE REFERENCE VP 36 State at Termination 4 6 7 2 e Start a t
19. 009 9 11 2007 minutes 3 2 30 fire alarm verification 4 2 2008 3 9 2009 minutes editing minutes editing 3 2 24 3 2 24 3 2 30 3 2 30 IDS foadd MN faded i IOS foad ON faded duress duress fire alarm verification fire alarm verification 9 11 2007 minutes 3 2 31 fire zone mS A 4 2 2008 3 9 2009 minutes editing 3 2 31 3 2 31 ja applied additional edits beyond added committee reviewed issue TN fire zone fire zone 9 11 2007 minutes 3 2 44 panic 4 2 2008 3 9 2009 9 11 2007 minutes 13 2 58 transmission 4 2 2008 3 9 2009 minutes editing minutes editing 3 2 44 3 2 44 3 2 58 3 2 58 panic panic OS 2 TN f dded i IDS foadd ON fea transmission transmission 9 11 2007 minutes 3 263 violated IDS kfagreed 4 2 2008 3 9 2009 4 2 2008 3 9 2009 minutes editing minutes editing 3 2 63 3 2 63 4 2 2 4 4 2 2 4 DS foadd 4 MN f dded i IDS todd 4 violated violated entry exit TN fadded i entry exit 19 19 19 20 20 20 21 21 22 22 9 11 2007 minutes 4241 activation Is fagreed 4 2 2008 3 9 2009 minutes editing 4 2 4 1 4 2 4 1 IDS toad TN faded i activation activation 9 11 2007 minutes 46 71 audible IDS agreed 4 2 2008 3 9 2009 9 11 2007 3 9 2009 minutes editing minutes editing 4 6 7 1 4 6 7 1 4 2 2 4
20. 1 2007 The default setting for the cross zone option shall be that it is disabled NOTE When the time period elapses without the trip of the second zone it is recommended that an error transmission be sent that reports a trip in a cross zone was not verified 4 3 2 Swinger Shutdown A programmable swinger shutdown shall be required for each non fire zone such that a programmable one to six trip s shall shut down the zone The zone shall be restored by a manual reset or may be reset automatically after eight 8 hours with no further trips on the zone The default setting for this option shall be one trip for swinger shutdown NOTE Zones disabled by swinger shutdown shall not transmit restoral signals until they are returned to service NOTE A Swinger Trouble code may be transmitted upon the occurrence of additional trips on the zone NOTE Swinger shutdown may be disabled on any non fire zone that does not require police response 4 3 3 Fire Alarms Fire alarm verification shall be an available option on fire zones When used the system shall begin an Alarm Transmission Sequence once the conditions for fire alarm verification are met The default setting for the fire alarm verification option shall be that it is disabled 4 4 Power caused false alarms To reduce the incidence of false alarms caused by power problems the following shall be required 4 4 1 Power Variations The control panel shall prevent false alarms due to
21. 2 2 5 indicate when option is required e 4 3 2 1 6 trips for swinger shutdown SIA 2000 2009 All rights reserved Page xiii DRAFT 13 March 2009 ANSI SIA CP 01 2009 Control Panel Standard Features for False Alarm Reduction 1 Scope This standard details recommended design features for security system control panels and their associated arming and disarming devices to reduce the incidence of false alarms These features are applicable to both residential and commercial properties protected by an electronic security system This standard is intended for use by manufacturers in the design of control panels and alarm signal receivers It is also intended for reference by all affected parties including security system installers specifiers and users central station owners and operators manufacturers of central station products such as receivers and automation software and local authorities This standard assumes that communications to the central station will be conducted by a robust contemporary communication protocol such as the SIA Digital Communication Standard SIA Format Protocol for Alarm System Communications This standard is voluntary 2 Normative references 2 1 Related Documents Additional guidance on areas relating to this standard as noted and otherwise can be obtained from the sources below Features within this standard are in part based on data and recommendations from the following publicat
22. 4 2 5 4 1 4 2 6 1 amp 4 2 6 2 Page 35 ANSI SIA CP 01 2007 SECTION 2 SENSOR CAUSED FALSE ALARMS io be performed on each partition of the UUT VALIDATION PROCEDURE REFERENCE VP 23 Cross Zoning 4 3 1 e Verify that no zones are defaulted in a cross zoned arrangement e Program two zones in a cross zoned arrangement e Arm the UUT and wait until the Exit Time is expired e Trip one of the zones that are programmed as a cross zone e At the expiration of the cross zone time verify that there is no local alarm and that no alarm has been transmitted e Ifthe feature is available verify that an error is transmitted that reports that a trip in a cross zone was not verified e Disarm and rearm the UUT e Program two zones in a cross zoned arrangement e Arm the UUT and wait until the Exit Time is expired e Trip the other zone in the cross zoned pair e At the expiration of the cross zone time verify that there is no local alarm and that no alarm has been transmitted e Ifthe feature is available verify that an error is transmitted that reports that a trip in a cross zone was not verified e Disarm and rearm the UUT e Program two zones in a cross zoned arrangement e Arm the UUT and wait until the Exit Time is expired e Trip one of the zones that are programmed as a cross zone e After the cross zone time has expired trip the other zone in the cross zoned pair e Atthe end of the second cross zone time verif
23. Kovaciss RE E Rick Sheets GUI Fr en de needed Tom Harris SE EE Richard McKeown Tee aa Lou Fiore ERR ERE Ralph Sevinor SE A Pat Devereaux Eee EE Kevin McCarthy PAGO SE ETER Gary Klinefelter E A saus Frank Clark HE PU Ad ut al ta rol tkd Chuck Christiansen HE POSEA Messi Brian Moses ln o ii o be Aes Bill DeVoe PID Ir E E o O E Mark Peterson ala EEE EEE RE EE Rob Zivney EET EE Gordon Hope EEE ERE OE EN Isaac Papier IDS Research and Development INC nrnrnnnnrnnannvnnnnnvnnnnrennrvnnnrnnnnnvnnnnnenennne Jeffrey Zwirn Integrated Command SOW Ale iss sccisscccassisctecstaastnnsiatecedsgsbiadigaetaaniesneasiagenadic R Hunter Knight Integrated Command SO Was dis Sherrie Knight EEE ET George Bish en RR eure eneae a eet acetate Dale Eller Le NE leone eeepc Rick Simpson FSA Dave Smith eee Pol iAs Per Hanssen sandia National Laboratories a ias George Wagner CUE an coa Bill Newill UNA a a A AN Scott Baker EEE Larry Kern O Chris Hernandez Security Actes Design LL Richard Kelley Seguel Tc sd Ted Nesse Siemens Building Technologie S isse aaas Noelle Britton siemens Building Technol gis vu vs nntvh viten Bill Gorski ER NE EE Hunter Knight SJ ERE ERE A A A terete te Mark Visbal State De EE ER EE Joe Miskulin RE ET O Lou Chavez EE EE y 3nA An Derek Mathews U S Department of Commerce NIST mrnrnnnnrnnannvnnnnnvnnnrrnnnvnnnrrnnnnvnnnnnnnnnnr Ron Martin US Department of Commerce NS Tirant ets Jim Dray A NE Pam Petrow Page vi
24. Not required for Fire alarms Table B 2 Entry and System Disarming Sequence Clause 4 2 3 30 seconds to gt 4 minutes Default 30 seconds During Entry Delay Prior to Expiration of the Entry Delay I rights reserved Initiates Annunciation Progress Audible Annunciation Disarms the Alarm System kem me faen feommeme Entry Delay Clause 4 2 3 1 System shall Disarm by at a minimum entry of the user code only Page 23 ANSI SIA CP 01 2007 Abort Window Clause 4 2 5 1 Disarm Clause 4 2 5 1 1 8 4 2 5 1 2 Cancel Window Clause 4 2 5 4 Disarm or Disarm Function Key Clause 4 2 5 4 1 Disarm Clause 4 2 5 3 Page 24 Table B 3 Alarm Transmission Sequence Clause 4 2 5 Non Fire 15 to 45 seconds During Abort Window Starts at the end of the Abort Window gt 5 minutes During the Cancel Window After an alarm report Sounds the Local Alarm Annunciator Sounds Alarm Condition Aborts the Alarm Transmission Sequence Transmit Alarm End of the Abort Window Transmits Alarm Signal Clause 4 2 5 2 Transmit a Cancel Signal Disarms the Alarm System May disable by zone zone type Default time Non Fire 30 sec System shall Disarm by entry of the user code only Option Annunciate that no Alarm Transmission was made Applies to all alarms that have been subject to the Abort Window Cancel Signal is transmi
25. OO WOM A AN v 1 A E E E A stead E E ste eect anaes 1 2 Normativ references viss aaa aaan r vi di aaa Aaaa aaaea aa Aaaa Gage aeaa aAa a a aa aaaea dadaa deiade iadi 1 2 1 Related Documents cciccsissiecicccwdsscsessneavubeccceastacevnaxserecennsn sounder idad adan 1 2 2 Supporting DOCUMENTS iii anidan 2 2 3 Precedente eaei naeun tocino cine inclinacion insano naaa 2 3 Conventions and Definitions ccscccceseseseseecssscececececececececececececesseeeeeeeeeeeeeeeeseeeeeseeeseesansnsnsaeseseess 2 3 1 CONVentions umuuum usmmisiisdmdddssvdmmuee iii 2 7 0 O SAA A te casecsseuzes caeacacedescacaaeanecsuccustucsusGunscavecace map bean bousecsoatece buen senscauecassadaaeey 2 3 1 2 Tol ra OS ii ainia 2 3 1 3 Special CapitaliZation s i isori ii ii ende 2 3 1 4 Nomenclature and Identification of Clauses a asasanananananannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnenennenennnensnenenenennn 3 3 1 5 Binding Language ssie ic aa iaia aaa a a 3 3 2 Terms and detinitions i ia ssh da wave da aaa doo eaaa e aae Aan da deen a aAA a hidak desidia add dodne 3 4 ReguirementS iseia ereraa nae aE a 9 4 1 PATONES re inie einne ani 9 4 2 User Gaused False AAS a r aaa 9 42 1 O E TE EET 9 4 22 Arming and Eli 9 A23 JEhtry and Disarmingu reisien cines 11 4 2 4 Remote Control DO OS iii dia Ia ai Da 12 4 2 5 Alarm Transmission Sequence cmo nnn mannen nna 12 4 2 6 gt Ina dvertent Duress uni n ia tai dctusunntngunvosaceuadsceutususedinese
26. Roe Phoenix Police Department Lua rmnnsernanesm enste masennnudvtnd Rebecca Buckhannon SEG PRA saveacedecesanadtaeetduc eam icivaanmeddaentedecnddasedaneess Dr Jimmy Salinas Secun RECESS Design Gr up uuseamnsenmmmebsenngsnin masse enste Jack Sigler Security Sales Integration Magazine oi Bob Dolph see Ted Nesse A ae Rick Muller O Stan Martin HA A A A elects Ron Walters esse A Frank Clark A E NENN Ted Nesse RR E A E E E E E Al Gengler Vee Derrick Mathews JRR RE EV Jim Lesniak Re NT NR err reer err et Karen Fine A o sdvanteradesssenaceeiuelednenacuensee Lou Chavez ve Wes Schroeppel O SIA 2000 2009 All rights reserved Page vii ANSI SIA CP 01 2009 DRAFT 13 March 2008 REVISION HISTORY The following are changes made to this document listed by revision FEBRUARY 1994 BASELINE Original Publication AUGUST 1997 REVISION Added Appendix Recommended Self Validation Test Procedures APRIL 1999 REVISION Numerous and extensive changes including Conventions used in the document Ranges and default settings of time sensitive features Terms used to describe certain timing features Specific treatment of features that are allowed though not required Additional requirements for arming stations especially for remote arming and manual alarms Additional requirements for power caused false alarms Minor clarifying language throughout Reference to programming at installation Reference to UL product listing to this standard
27. SIA Standards Committee Security Control Panels Working Group Committee Meeting ISC West Las Vegas NV Wednesday April 1 2009 1 00 3 30 p m Room 507 Venetian DRAFT AGENDA 1 Calo Order noo EAR 27 ROIC all NTT a 3 SIA Antitrust PON sali 4 Approval of Draft Agenda ccccccccccccccccnccononononnncnnnnnononnnnnnnnnnnnnnnonnnnnnnnnnnnnoncnonnnnnnnnnnnos 5 Approval of the Draft Minutes of the 2008 10 29 Meeting ccceecceeeeeeeeeeeeeeeeeeeeees 6 Grarmers Remarks cups eee 7 Security Industry Alarm Coalition www siacinc org Update ocoocccnnccnncnnccccncccncccnnnns 8 Requests for CP 01 Interpretations ooocociconiciniccncccnccnncconncnnnnnnncnnnnnnnnnoncnnnnnnnnnnnnnnnnnn 9 Revision of CP 01 2007 DISCUSSION NOMS iis sicccicticcsttlinetcnccccnsdissseaccdeomenenssseradenlioncceed a Review comments from delta document included with Agenda b Review status of changes for lightning and thunder 4 3 4 c Schedule final draft and review process 10 Brief Update on Glossary Project cc ccccccceeeee eee eesesececenseeeeeenesseneaneneeeeneenenseaneees http spreadsheets google com ccc key pqqV5kS TN3Dzlj7LfdsdpCg amp hl en 11 Next Meeting and Adjournment oooconicccccconnnononannononnnnnnn cnn M Rigano T Nesse T Nesse Agenda Item 9 a Control Panel Standard Features for False Alarm Reduction ANSI SIA CP 01 2009 Revision of ANSI SIA CP 01 2007 Discussion D
28. VP 14 clarified for Remote Control Device e VP 21 deleted Attempt to program the duress code as a user code but with the last digit incremented by 1 Verify that the UUT will not accept it either in programming or in use e VP 25 Fire Alarms reworked e VP 29 Call Waiting added Note The dial sequence for call waiting cancel is typically lt 70 gt lt pause gt on a DTMF line but may vary depending on the region of the country To test this feature a DTMF test set may be used to confirm that the control can dial lt gt and all the digits on a standard DTMF phone e VP 38 Default Settings added e Annex A Informative Programmable Features added 4 2 5 4 e Annex D Informative Recommended Self Validation Procedures added text These procedures are intended for use by the manufacturer to validate their design and for use by UL to confirm compliance SIA 2000 2009 All rights reserved Page xi ANSI SIA CP 01 2009 DRAFT 13 March 2008 2009 Annex E Informative added text UL Listing Since the standard requires both a local alarm and off premise transmission UL is requiring that products they test to it be UL listed for both a local and off premises reporting Any hardware device added to a system to meet the requirements of this standard needs to be UL listed or UL will test to verify that a failure of this device does not compromise the existing UL requirements of the system Previous Annex F
29. alarm Disarm the UUT or Disarm and depress the appropriate function key to cancel the alarm Verify that the UUT annunciates that a Cancel has been transmitted Verify that the UUT transmits a Cancel signal and annunciates that a Cancel was transmitted OTHER USER CAUSED FALSE ALARMS VP 21 Unique Duress Code f duress is supported Verify that the UUT duress feature is disabled as a default Arm the UUT Attempt to initiate a Duress alarm Verify that no Duress alarm was initiated Disarm the UUT Reprogram the duress feature to enable it Arm the UUT Initiate a Duress alarm Verify that a duress alarm is transmitted Disarm the UUT Attempt to program the duress code to match each of the other codes accepted by the UUT Verify that the UUT will not accept it either in programming or in use Program the UUT with a valid duress code Attempt to program a user code to match the duress code Verify that the UUT will not accept it either in programming or in use VP 22 Initiation of Manual Alarms Arm the UUT Activate a manual alarm Verify that a double action trigger was used to activate the alarm Acceptable double action trigger activation is typified by the examples given in Clause 4 2 7 of the standard This should be done for all types of manual alarm activations supported by the remote control device EOT SIA 2000 2009 All rights reserved ANSI SIA CP 01 2009 REFERENCE 4 2 5 4 amp
30. am the Entry Delay to 29 seconds and verify that the time between the trip and the local alarm is 30 seconds or greater Note If the UUT did not accept programming to 29 seconds proceed to the next test Reprogram the Entry Delay to 240 seconds and verify that the time between the trip and the local alarm is 240 seconds Disarm the UUT VP 9 Progress Annunciation Arm the UUT and wait for the Exit Time to expire Trip an entry exit zone Verify that the UUT annunciates during the Entry Delay and that the annunciation is different than an alarm VP 10 Disarm Arm the UUT and wait for the Exit Time to expire Trip an entry exit zone During the Entry Delay enter a user code Verify that Progress Annunciation is silenced on the first keystroke of the user code Verify that the system Disarms Arm the UUT and wait for the Exit Time to expire Trip an entry exit zone During the Entry Delay enter an invalid user code Verify that Progress Annunciation is silenced on the first keystroke of the invalid user code Verify that Progress Annunciation resumes after the last digit of the invalid user code or after the time specified by the manufacturer Verify that the Entry Delay is still 30 seconds REMOTE CONTROL DEVICES SIA 2000 2009 All rights reserved Page 31 ANSI SIA CP 01 2007 VALIDATION PROCEDURE VP 11 Control Buttons e Verify that the remote control device buttons are mechanically designe
31. annunciation shall be produced upon entry to warn person s entering the premises that the Entry Delay has begun This annunciation shall be distinct from the annunciation produced when the system is in alarm The progress annunciation of an entry delay needs to be audible at a minimum 4 2 3 3 Disarm When the system is in an Entry Delay the system shall Disarm by a single step procedure Procedures may include the entry of a user code without additional keys or the presentation of a credential Systems may implement one or both of these procedures Alternative disarming methods may co exist SIA 2000 2009 All rights reserved Page 11 ANSI SIA CP 01 2007 Progress annunciation shall be silenced upon entry of the first digit of the user code Progress annunciation shall resume upon entry of an invalid user code or after a manufacturer specified time during the Entry Delay If multiple keypads are annunciating the entry delay one or more keypads may be momentarily silenced 4 2 4 Remote Control Devices Devices that remotely control the functions of the alarm system if used shall have the following features 4 2 4 1 Control Buttons Remote control device buttons including Duress Holdup and Panic shall be mechanically designed in such a way so that inadvertent activation of remote commands shall be minimized The requirements applied for system control buttons are not the same those as for buttons to initiate manual alarms
32. any operation code including Duress codes 4 2 7 Initiation of Manual Alarms Alarms that are manually initiated at an arming station shall require a double action trigger A single button which must be held to initiate the manual alarm does not comply with this requirement NOTE Implementation of this feature may include but is not limited to any of the following e Simultaneous depression of two buttons where if either of the buttons have multiple functions the two buttons are non adjacent i e can t be pressed with one finger e Depression of a single button after lifting the cover that normally protects it if the cover protects only emergency function buttons 4 3 Sensor Caused False Alarms To reduce the incidence of false alarms caused by sensors the following shall be required 4 3 1 Cross Zoning A cross zoning option shall be included with the following features e The cross zone option shall be programmable by zone e The cross zone option shall require a trip on two zones within a given time period to start an Alarm Transmission Sequence as described in Clause 4 2 5 Alarm Transmission Sequence and its subclauses e The time period shall be initiated by the trip of the first zone e The time period shall be programmable or specified by the manufacturer and shall be consistent with the requirements of any UL standards for which the panel is listed SIA 2000 2009 All rights reserved Page 15 ANSI SIA CP 0
33. are initially programmed to the default settings specified in the standard e the UUT is Disarmed and returned to its default configuration after each test noted as End of Test EOT These procedures are generic and highlight various implementation details specific to an individual UUT in italics print where the standard allows certain freedom of design These procedures are non binding and are not intended to add to or supplant the requirements of the standard When the requirements of the standard and these procedures appear to be in conflict the requirements of the standard have precedence VALIDATION PROCEDURE Pre test Appendix A Verify that all selectable options of the UUT are defaulted as listed by the table in Appendix A of the standard Refer to the UUT s quick reference chart or card 4 6 1 SIA 2000 2009 All rights reserved Page 27 ANSI SIA CP 01 2007 SECTION 1 USER CAUSED FALSE ALARMS to be performed on each partition of the UUT VALIDATION PROCEDURE VP 1 Panel Annunciation Verify that the UUT has an output for an auxiliary annunciation device that will sound all annunciations required by the standard Verify that the UUT has an output for remote annunciation devices that will sound progress annunciation during Entry Delay and Exit Time EXIT TIME VP 2 Exit Time Verify that the UUT s Exit Time is defaulted for all entry exit zones that have a unique default settings to 60 seconds
34. ative Programmable Features rrrnnanavvrvnnnnnnnnnnnnvn nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnn 21 Annex B informative Arming Disarming and Transmission Sequences nrssrrnnvnnnnnvnnnnnnnnnnnnnnnnnnnnnnnner 23 Annex C informative Event Timing Diagrams mnnsvrnnnvnnnnnvnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 25 Annex D informative Recommended Self Validation Procedures rrrsnsrrrannnnvnnnnnnnvennnnnnnnnnnnennnnnnennnnnnenn 27 Annex E informative Product Marking amp Listing rrannvnnnnnnnvnnnnnnnvnnnnnvnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnennnnnnnnnnnnnnnn 43 Annex F informative Clarifications on Effectivity rrsrerrnnnnvornnnnnver nnnvnnnnnnnvnnennnnvnnennnnvnnnnennennnnvnnennnnvenennn 44 Annex G informative New Central Station Signals rrnnnvnrnnnnnvnnnnnnnennnnvevnnnnnnernnnnnnernnnnnnensnnnernnnnnennnnnnenn 45 I New Signals Required by CP 01 2000 rrrrnnnvnnnnnvnnnnvnnnnvnnnnnnnnvnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnen e 45 ll New Signals Allowed or Recommended by CP 01 2000 rrnnavnnnnvvnnnvnnnnnvnnnnnnnnnnnnnnnnnnnvennnnnnnnnnnnnnnnnnnnnnnnnnn 46 Annex H informative Common Nomenclature s rrxsnnvnrnnnnnvnnnnnnnnnnnnnevnnnnnnernnnnnnernnnnnnernnnnnnnnnnnennnnnnnennnnnnenn 47 Annex I informative System Configuration Identification Ref 4 6 1 1 rrrnnnnrnrrnnnnvvvrnnnnvnennnvnnennnnnnvennnnr 48 Annex J in
35. ature disabled at the time of installation If the control panel supports a silent exit feature and it has been invoked the audible progress annunciation shall remain silenced during the additional Exit Time and the duration of the additional Exit Time shall be doubled for that additional exit period only but shall not exceed two hundred and fifty five 255 seconds 4 2 2 4 Exit Error An Exit Error sequence shall be initiated if an exit entry zone is in a violated state or condition at the instant of exit time expiration This section applies to entry exit zones only All non entry exit type zones will adhere to the manufacturers specifications relative to Exit Error An Exit Error shall be processed as follows e The local alarm shall immediately sound e The annunciator shall sound an Entry Delay or an alarm condition e An Entry Delay shall be initiated Page 10 SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 e lf the alarm system is not Disarmed at the end of the Entry Delay the Alarm Transmission Sequence shall be initiated e The Alarm Transmission shall include the alarm and an Exit Error message to the remote station 4 2 2 5 Unvacated Premises An option shall be provided which allows the security system to Arm in the Stay Arm mode if the Exit Time expires and no exit has been made The default setting for this option shall be that it is enabled This option if enabled is required to b
36. by a person in response to a threat 3 2 45 partition a defined area within the security system that can be Armed and Disarmed independent of the other area s but operated under a single system control Dedicated or shared user interfaces may be used to operate a partition 3 2 46 point an electronically addressable sensor sometimes used interchangeably with the term sensor The term is usually used in multiplex alarm systems or for RF wireless sensors 3 2 47 premises the facility being protected by a security system 3 2 48 primary power power provided by a commercial source that is normally available at the premises 3 2 49 Recent Closing a transmission indicating that the security system has recently been Armed 3 2 50 report an electronic transmission sent by the control panel to the central station containing detailed information about an event detected by or status of the security system 3 2 51 remote control device any device that can be used at a location remote from the control panel to control the functions of the control panel This includes portable wireless devices dead bolt sensors located in the entry door assembly or any other device intended to arm or disarm the control panel when activated One of the purposes of a remote control device is to eliminate the need for arming and disarming delays by giving the user a means of arming or disarming before or simultaneous with entry or exit Some remote
37. cecssduvobusnccesdendes 15 4 2 7 Initiation of Manual Alarms seennnrnnnnnnnnnnnnnnnn ovnnnnnnnnunnnnnnnnnnnnnnnunennnsvennnnnnnnnnnnunnnnnnnnnnnnnnnunnnnunennnnnnnnn 15 4 3 Sensor Caused False Alarm iii ica airada diana 15 AE O OY A O dues s4ccutecustaccedtanee 15 43 2 Swinger Shutdown ocio illa 16 4 3 3 RN A dscn acd vesnsncadeunde sngdadsddcuuquadesedadeSadadenegascaas susnazencgundegdebeadacadace 16 4 4 Power caused false alarms ssnsunnnrnornnnnnnnnun unnnvnnvnnnnnnnnennnennnnnnnnnunnnnnnennnennnnnnnnnunnennnnnnnnnnnnnnnnnsnevenen 16 4 41 Power SA A 16 4 42 A taken aA EEE 16 4 4 3 REStOration Of POWER a isi cccieces sscwsvacacencdnscsenoncensstansanctnsesderkodesuecbecuecusersvsccucsensansaacsuucesuadadaucsasssceesaeease 16 4 5 Call Waiting sense eee damene tsarens 16 4 6 Install tion and O A Cece boas cu E as ghaasoeaccdags 17 46 1 QUICK ReTerence cional S 17 4 6 1 1 System Configuration Identification rrssrnnnnvnnnnvnnnnnvnnnnnnnnvnnnnnnnnnvnnnnnnnnnnnnnnnnnnnnnnnnnvnnnnnnnnnnnnnnnnnnnnnennn 19 4 6 2 Partitioned Syste M Sa rr aer dais 19 AS A E E E E E E E T 19 460 4 Initiation of Testi cine illa adi add 19 4 6 5 A EEE T E A EA rd he ha hire E dd dueaduadccdaceae 19 4 6 6 Testin Progressui hunnene een id 19 46 7 gt Termination Of O A 19 4 7 Default Settings seas ere 20 SIA 2000 2009 All rights reserved Page iii ANSI SIA CP 01 2009 DRAFT 13 March 2008 Annex A inform
38. cept where otherwise indicated Default settings are listed in Annex A Page 20 O SIA 2007 All rights reserved PARAGRAPH 4 2 2 1 4 2 2 2 4 2 2 3 4 2 2 5 4 2 4 4 4 2 3 1 4 2 5 1 4 2 5 1 4 2 5 1 2 4 2 5 4 4 2 5 4 1 4 2 6 1 SIA 2000 2009 All rights reserved DRAFT 13 March 2009 Annex A informative Programmable Features ANSI SIA CP 01 2009 Table A 1 Shipping Defaults and Recommended Programming FEATURE Exit Time Progress Annunciation Disable for Silent Exit Exit Time Restart Auto Stay Arm on Unvacated Premises Exit Time and Progress Annunciation Disable for Remote Arm Entry Delay s Abort Window for Non Fire Zones Abort Window Time for Non Fire Zones Abort annunciation Cancel Window Cancel Annunciation Duress Feature REQUIREMENT Required programmable Allowed Required Option Required Option except for remote arm Allowed Option for remote arm Required programmable Required Option Required programmable Required Option Required Required Option Allowed Option SHIPPING DEFAULT For full or auto arming 60 Seconds 45 sec 2 min 255 sec max Individual keypads All may be disabled annunciators enabled For re entry during exit Enabled time If no exit after full arm Enabled May be disabled for Enabled remote arming mi May be disabl
39. cess F 5 2 To continue labeling compliant products would have to be submitted for a file review completed before the effective date of the edition Page 44 SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 Annex G informative New Central Station Signals This annex describes the new signals alarm panels will send in compliance with the SIA CP 01 false alarm reduction standard It is divided into two categories required and optional signals Note The DC 03 and DC 05 references provided below are for information only Please refer to the appropriate SIA Standard for the latest information I New Signals Required by CP 01 2000 Exit Error This signal is sent if an entry exit zone is violated at the expiration of an exit delay In accordance with SIA DC 03 this signal can be one of 2 signals 1 EA zone ID 2 EE User Number When SIA DC 05 is used this signal is sent as 1 374 Zone ID In addition the following signal may also be sent 1 457 User Number Recent Closing This signal is sent if an alarm occurs within two minutes of the expiration of an exit delay In accordance with SIA DC 03 this signal is sent as CR User Number When SIA DC 05 is used this signal is sent as 1 459 User Number Cancel This signal is sent when an alarm is canceled Cancel is not a new signal but it is mentioned for inclusion in the Central Station Standards In accordance with SIA DC 03 t
40. clude additional product features or functions nor to act as a maximum performance limit Any product the specifications of which meet the minimum requirements of a SIA standard shall be considered in compliance with that standard Any product the specifications of which exceed the minimum requirements of a SIA standard shall also be considered in compliance with the standard provided that such product specifications do not exceed any maximum requirements set by the standard SIA standards are not intended to supersede any recommended procedures set by a manufacturer for its products SIA reserves the right to revise this document at any time Because SIA policy requires that every standard be reviewed periodically and be revised reaffirmed or withdrawn users of this document are cautioned to obtain and use the most recent edition of this standard Current information regarding the revision level or status of this or any other SIA standard may be obtained by contacting SIA Requests to modify this document are welcome at any time from any party regardless of membership affiliation with SIA Such requests which must be in writing and sent to the address set forth below must clearly identify the document and text subject to the proposed modification and should include a draft of proposed changes with supporting comments Such requests will be considered in accordance with SIA s standards development policies and procedures Written requests for int
41. d so that inadvertent activation is minimized Reference the manufacturer s product literature if necessary VP 12 Manual Alarms Arm the UUT Activate a manual alarm Verify that a double action trigger was used to activate the alarm Acceptable double action trigger activation is typified by the examples given in clause 4 2 7 of the standard This test should be repeated for all types of manual alarm activations supported by the remote control device VP 13 System Acknowledgment Arm the UUT from the remote control device Verify that the UUT acknowledged the command in a manner that would normally be discernible from the exterior of the premises Disarm the UUT from the remote control device Verify that the UUT acknowledged the command in a manner that would normally be discernible from the exterior of the premises VP 14 Remote Arming e Arm the UUT from the remote control device e Verify that the Exit Time is 60 seconds and that Progress Annunciation occurs If the remote control device has a silent exit feature Arm the UUT from the remote control device with the silent feature invoked Verify that the Exit Time is 120 seconds Arm the UUT normally from the remote control device Verify that the Exit Time is 60 seconds ALARM TRANSMISSION Page 32 SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 VALIDATION PROCEDURE VP 15 Abort Window Verify that the UUT s Abort Windo
42. dow will not be programmed to exceed one minute 4 2 5 1 1 Disarm When the system is in an alarm condition the system shall Disarm by a single step procedure Procedures may include the entry of a user code without additional keys or the presentation of a credential Systems may implement one or both of these procedures Alternative disarming methods may co exist When systems require entry of a user code alarm annunciation at the keypad shall be silenced upon entry of the first digit of the user code Alarm annunciation shall resume upon entry of an invalid user code or after a manufacturer specified time during the Abort Window 4 2 5 1 2 Abort If the alarm system is Disarmed within the Abort Window no alarm transmission shall occur An option shall be provided that the alarm system will annunciate that no alarm signal was transmitted The default setting for this option shall be that it is enabled NOTE A transmission may be sent indicating that an alarm has been aborted 4 2 5 2 Alarm Transmission The Alarm Transmission shall occur at the end of the Abort Window 4 2 5 3 Disarm Upon disarming the system after any alarm has been reported except for a Duress alarm the panel shall indicate that an alarm had occurred and shall at a minimum indicate which zone s had been violated during the armed period 4 2 5 4 Cancel Window A period of time shall be provided starting at the end of the Abort Window during which a us
43. e ANNUNCIATOR Exit Annunciation unique LOCAL ALARM COMMUNICATION User Arms the Alarm System SIA 2000 2009 All rights reserved Page 25 ANSI SIA CP 01 2007 Exit Error System Arm with entry exit zone in violation at the end of the Exit Time Clause 4 2 2 1 4 2 2 2 4 2 2 4 and 4 2 5 TIME MIN SEC 00 SYSTEM STATE ANNUNCIATOR Unarmed Exit Time Exit Annunciatio LOCAL ALARM COMMUNICATIO N User Arms the Alarm System gt System Entry and Disarm Clause 4 2 3 TIME MIN SEC 00 SYSTEM STATE ANNUNCIATOR LOCAL ALARM COMMUNICATION Violation of an entry exit delayed zone 2 1 30 50 1 00 2 00 Entry Delay Abort Window Alarm Transmission Alarm Annunciation n Unique Entry or Alarm Annunciation Sounds until alarm time out TX Alarm Exit Error amp Entry exit zone violated between times 00 and 1 00 and remains violated at the end of the Exit Time lt 30 Armed Entry Delay Entry Annunciation Disarmed amp Entry of Valid Disarm code Trip of entry exit zones Clause 4 2 3 and 4 2 5 TIME MIN SEC 00 SYSTEM STATE ANNUNCIATOR LOCAL ALARM COMMUNICATION Violation of a delayed zone gt Entry Delay Abort Window Entry Annunciation Alarm Annunciation 30 1 00 Alarm Transmission Sounds until alarm time out Transmit Alarm Trip of non entry exit and non Fire zones Clause 4 2 5 TIME MIN SEC 00
44. e UUT e Trip a sensor on a fire zone that has been configured for alarm verification Hold the tripping means in place e Verify that an alarm signal is transmitted within the time frame designated by the manufacturer EOT Page 38 O SIA 2007 All rights reserved DRAFT 13 March 2009 SECTION 3 POWER CAUSED FALSE ALARMS VALIDATION PROCEDURE VP 26 Power Variations Arm the UUT and wait until the Exit Time is expired Vary the primary and secondary power supplied to the UUT between the maximum manufacturers specifications and 0 zero Verify that no alarms are transmitted VP 27 Labelling e Verify that labelling is present on the UUT interconnect label that indicates the voltage under the full rated load at which the UUT ceases to process sensor trips VP 28 Restoration of Power Arm the UUT and wait until the Exit Time is expired Reduce the primary and secondary power to 0 zero Restore the primary power Verify that the UUT resumes the same state of arming and bypassed zones as when power was removed Trip any sensor within 60 seconds of restoral of primary power Verify that the UUT disregards input from the sensor SECTION 4 CALL WAITING VALIDATION PROCEDURE SIA 2000 2009 All rights reserved ANSI SIA CP 01 2009 REFERENCE Page 39 ANSI SIA CP 01 2007 VALIDATION PROCEDURE VP 29 Call Waiting e Program a CALL WAITING CANCEL dialing sequence Note The dial
45. e invoked when the system is Armed Away by the user from within the protected area and when areas of the system have Stay and Away arming states This option is not required when arming occurs by time schedule or is performed with a remote control device 4 2 2 6 Recent Closing A Recent Closing transmission shall be sent if an alarm occurs within two 2 minutes after the expiration of the Exit Time If the user number is available it shall be included in the Recent Closing transmission Recent Closing transmissions are not required for Fire alarms A Recent Closing transmission is allowed but not required if an alarm condition occurs between Arming and the end of the Exit Time The Recent Closing signal is separate from the closing signal 4 2 3 Entry and Disarming To reduce the incidence of false alarms during Entry and Disarming the following shall be required for all armed states 4 2 3 1 Entry Delay Programmable Entry Delays shall be included The programmable range for all Entry Delays shall be from thirty 30 seconds to at least four 4 minutes The control panel default setting for all Entry Delays shall be thirty 30 seconds If the system is not disarmed during the Entry Delay the Alarm Transmission Sequence shall begin when the Entry Delay expires The minimum time given is an absolute minimum and panels are not to allow Entry Delay s of less than 30 seconds 4 2 3 2 Progress Annunciation A distinct
46. ed by Enabled zone or zone type 15 sec 45 sec 30 Seconds Annunciate that no Enabled alarm was transmitted Minimum duration of the window shall be five 5 minutes Annunciate that a Enabled Cancel was transmitted No 1 derivative of Disabled another user code No duplicates with RECOMMENDED PROGRAMMING 60 Seconds All annunciators enabled Enabled Enabled Enabled Enabled all zones At least 30 Seconds At least 15 seconds Enabled Not required to be programmable Enabled Disabled Page 21 ANSI SIA CP 01 2007 PARAGRAPH 4 2 6 2 a Programmable Cross Zoning Time FEATURE Swinger Shutdown Fire Alarm Verification Call Waiting Cancel 4 3 2 Swinger Shutdown Disable REQUIREMENT Required Option Allowed Required programmable Allowed Required Option Required Option RANGE other user codes Programming needed May Program For all non ire zones shut down at 1 or 2 trips For non response zones police Depends on and sensors panel Depends on phone line user SHIPPING DEFAULT Disabled Per manufacturer One trip Enabled Disabled Disabled RECOMMENDED PROGRAMMING Enabled and two or more zones programmed Per walk path in protected premises Enabled all zones Enabled unless sensors can self verify Enabled if user has call waiting Programming at in
47. em with each partition being operated independent of each other there shall be a system option indicating this manner of behavior When enabled each partition shall behave as if there were no other partitions incorporating all of the features of this standard If not enabled then when a partition is armed and or disarmed all partitions take on the state of said partition 4 2 User Caused False Alarms 4 2 1 Annunciation The control panel shall support an output to activate an auxiliary annunciation device for all sounds required by this standard The control panel shall support annunciation of exit and entry time in multiple locations within the premises 4 2 2 Arming and Exit To reduce the incidence of false alarms during Full Arming or automatic Arming the following shall be required except as noted in clause 4 2 4 4 Remote Arming An Auto arming option may exist and when enabled must meet all of the requirements of clause 4 SIA 2000 2009 All rights reserved Page 9 ANSI SIA CP 01 2007 4 2 2 1 Exit Time A programmable Exit Time shall be included The programmable range for all Exit Times shall be from forty five 45 seconds to at least two 2 minutes but shall not exceed two hundred and fifty five 255 seconds The control panel default setting for all Exit Times shall be sixty 60 seconds The minimum time given is an absolute minimum and panels are not to allow Exit Time s of less than 45 seconds If the c
48. em Acknowledgment must document if programmable must document 4 2 4 4 Remote Arming must document if programmable must document 4 2 4 5 Remote Disarming not required in quick reference not required in user manual 4 2 5 1 Abort Window must document see 4 2 5 1 1 4 2 5 1 2 4 2 5 1 1 Disarm Abort must document if programmable must document 4 2 5 1 2 Abort must document if programmable must document 4 2 5 2 Alarm Transmission not required in quick reference not required in user manual 4 2 5 3 Disarm not required in quick reference must document 4 2 5 4 Cancel Window must document if programmable must document 4 2 6 1 Use of Duress Feature must document see 4 2 6 2 4 2 6 2 Duress Code must document must document 4 2 7 Initiation of Manual Alarms not required in quick reference must document 4 3 1 Cross Zoning must document must document 4 3 2 Swinger Shutdown must document must document 4 3 3 Fire Alarms must document must document 4 5 Call Waiting must document must document 4 6 3 System Test must document must document 4 6 4 Initiation of Test not required in quick reference not required in user manual 4 6 5 Communications must document not required in user manual 4 6 6 Test in Progress not required in quick reference must document 4 6 7 Automatic Termination of not required in quick reference must document Test Page 18 SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 4 6 1 1 System Configuration Ident
49. er can Cancel the alarm The minimum duration of the window shall be five 5 minutes The Cancel Window shall apply to all alarms that have been subjected to the Abort Window 4 2 5 4 1 Cancel If an alarm has previously been transmitted a Cancel signal shall be transmitted if either the alarm system is Disarmed or both a Disarm and function key are depressed during the Cancel Window Some panels may require a special function key after Disarm to send a Cancel signal Page 14 SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 An option shall be provided that the alarm system will annunciate that a Cancel was transmitted The default setting for this option shall be that it is enabled An option may be provided to delay the Cancel signal and other non alarm signals until after termination of active two way voice sessions in the instance that the end user initiates a cancel sequence while a two way voice session is already in progress 4 2 6 Inadvertent Duress To reduce the incidence of inadvertent Duress signals the following shall be required 4 2 6 1 Use of Duress Feature If a Duress feature is provided its default setting shall be that it is disabled 4 2 6 2 Duress Code A Duress signal shall be sent by a unique Duress code only The control panel shall not derive the Duress code from an existing operating code such as a user code plus Duress digit sequence The panel shall not allow duplication of
50. ere one is arm normal with progress annunciation and one is arm silent no annunciation 4 2 2 3 Exit Time Restart added Panels may have this feature disabled at the time of installation SIA 2000 2009 All rights reserved Page ix ANSI SIA CP 01 2009 DRAFT 13 March 2008 e 4 2 2 4 Exit Error added An Exit Error sequence shall be initiated if an exit entry zone is in a violated state or condition at the instant of exit time expiration This section applies to entry exit zones only All non E E type zones will adhere to the manufacturers specifications relative to Exit Error e 4 2 2 6 Recent Closing added A Recent Closing transmission is allowed but not required if an alarm condition occurs between Arming and the end of the Exit Time The Recent Closing signal is separate from the closing signal e 4 2 3 1 Entry Delay added The minimum time given is an absolute minimum and panels are not to allow Entry Delay s of less than 30 seconds e 4 2 3 2 Progress Annunciation added The early progress annunciation of an entry delay needs to be audible at a minimum e 4 2 3 3 Disarm changed When the system is in an Entry Delay the system shall Disarm by a single step procedure Procedures may include the entry of a user code without additional keys or the presentation of a credential Systems may implement one or both of these procedures Alternative disarming methods may co exist Also
51. erpretations of a SIA standard will be considered in accordance with SIA s standards development policies and procedures While it is the practice of SIA staff to process an interpretation request quickly immediate responses may not be possible since it is often necessary for the appropriate standards subcommittee to review the request and develop an appropriate interpretation Requests to modify a standard requests for interpretations of a standard or any other comments are welcome and may be sent to The Security Industry Association 635 Slaters Lane Suite 110 Alexandria VA 22314 P 703 683 2075 F 703 683 2469 email standards siaonline org This document is owned by the Security Industry Association and may not be reproduced in whole or part without the prior written permission from SIA SIA 2000 2009 All rights reserved Page v ANSI SIA CP 01 2009 DRAFT 13 March 2008 ACKNOWLEDGEMENTS This standard was approved as an American National Standard by the Security Industry Standards Council SISC The voting members are listed below Acaquient Security Consul ria da Jack Sigler Acquient Security CONSUMING ninia Terry France MON NA A ia Dr Jimmy Salinas NT erect ree errr ree Tim Jeffries Re RE EEE Larry Dischert American Protective Services mmmmenssmissueresmis srariiggennensgnnesasnekdanene Dan Jacquish ERT tite mara wate ed tae Susan Melnicove Ear Fa A SG Ree Shane Clary Basch acu SINE Gant pb Stephen
52. est sequence e Terminate the test sequence and verify that the UUT resumes operation in a Disarmed state e Start a test sequence e Trip a 24 hour zone e Terminate the system test e Verify that no alarm signal is transmitted but that a trouble condition is indicated VP 37 Termination Report 4 6 7 3 e Start and terminate a test sequence e Verify that an end of test message is transmitted EOT VP 38 Default Settings 4 7 e Using the manufacturers supplied installation manual confirm that each relevant programmable feature has the default value as shown in Annex A e alternative procedure e Obtain a UUT configured for shipment e Using the UUT s builtin programming mode confirm that each relevant programmable feature has the default value as shown in Annex A END OF SELF VALIDATION PROCEDURE Page 42 SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 Annex E informative Product Marking amp Listing The following mark is available from Underwriters Laboratories Inc UL and is issued to compliant products tested and listed in accordance with UL procedures Listed Household Burglary Warning System Control Unit Issue No 999999 UL Design Evaluated by UL In accordance with SIA CP 01 Control Panel Standard Features for False Alarm Reduction UL Listing Since the standard requires both a local alarm and off premise transmission UL is requiring that products the
53. formative Labelling Ref 4 4 2 rrnnnnnnvvrnnnnnnnnnnnnnvnnnnnnnnvnnnnnnnnnnnnnnnnnnnnnnnnnn ecc 49 Page iv SIA 2000 2009 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 Foreword This standards document is published by the Security Industry Association SIA and was developed and adopted by a consensus of industry volunteers in accordance with SIA s standards development policies and procedures It is intended to facilitate product compatibility and interchangeability to reduce misunderstandings between manufacturers and purchasers and to assist purchasers in obtaining the proper products to fulfil their particular needs The existence of this or any SIA standards document shall not prevent any SIA member or non member from manufacturing selling or using products not conforming to this or any SIA standard SIA standards are voluntary SIA encourages the use of this document but will not take any action to ensure compliance with this or any other SIA Standard SIA assumes no responsibility for the use application or misapplication of this document Industry members using this document particularly those having participated in its development and adoption are considered by SIA to have waived any right they might otherwise have had to assert claims against SIA regarding the development process of this standard Although some SIA standards establish minimum performance requirements they are intended neither to pre
54. his signal can be one of 2 signals 1 BC Zone ID 2 OG User Number When SIA DC 05 is used this signal is sent as 1 406 User Number Start Test This signal is sent when the system is put into the test mode In accordance with SIA DC 03 this signal is sent as TS When SIA DC 05 is used this signal is sent as 1 607 User Number SIA 2000 2009 All rights reserved Page 45 ANSI SIA CP 01 2007 End Test This signal is sent when the system is taken out of the test mode In accordance with SIA DC 03 this signal is sent as TE When SIA DC 05 is used this signal is sent as 3 607 User Number ll New Signals Allowed or Recommended by CP 01 2000 Cross Zone Error CP 01 Clause 4 3 1 This optional signal is sent at the then end of a cross trip verification time if the trip was not verified by a second zone trip The purpose is to alert the central station that a possible faulty zone exists In accordance with SIA DC 03 this signal s may be sent as Unverified Events BG FG UG When SIA DC 05 is used this signal is sent as 1 378 Zone ID Swinger Trouble A zone that is shut down because of a swinger has just activated again In accordance with SIA DC 03 this signal is sent as BD Zone ID When SIA DC 05 is used this signal is sent as 1 377 Zone ID Swinger Trouble Restore A zone that is shut down because of a swinger has just restored It is still shutdown but the state of the zone
55. hould a connection not be established on the initial attempt an alternate dialing method that does not transmit the dialing sequence to disable call waiting shall be provided to assure that the connection failure was not due to the use of the call waiting cancel feature on a non call waiting line A caution shall be included with the panel alerting the installer that a call waiting cancel on a non call waiting line will prevent successful connection to the central station 4 6 Installation and Test To assist in both the installation and testing of panels to this standard the following shall be required 4 6 1 Product Documentation 4 6 1 1 Quick Reference A quick reference chart or card for the installer detailing the programming locations and testing procedures associated with the features of this standard shall be included Features that the control panel does not implement are not required to be included in the quick reference The quick reference section may be contained in the installation manual so long as it is a separate section Refer to table 2 for features to be included in the quick reference 4 6 1 2 User Manual Requirements The operation of CP 01 features that interact directly with the user shall be documented in the user manual Features that the control panel does not implement are not required to be included in the user manual Refer to table 2 for features to be included in the user manual Text similar to the following
56. ification For system configurations comprised of interchangeable components e g control equipment arming station annunciator local alarm communicator sub assembly etc a list of components that comprise of the CP 01 compliant system shall be provided The list shall be prominently available as part of the equipment s installation manual and shall include applicable information such as model numbers of the system components so that the complaint minimum system configuration is identified 4 6 2 Partitioned Systems For partitioned systems the requirements of clause 4 6 Installation and Test and its subclauses shall be capable of being implemented independently for each partition 4 6 3 System Test A mode of operation that allows testing of all zones the control all sounders and the communicator shall be included A procedure outlined in the manuals is an acceptable alternative to a special mode of operation 4 6 4 Initiation of Test 4 6 4 1 Panel Status The panel shall ensure that a system test cannot be initiated from an armed state 4 6 4 2 Initiation Report At the initiation of a test the control panel shall send a message to the central station that a test is in progress The message shall include the user number if it is available 4 6 5 Communications Communication with the monitoring station regarding the partition s zones or points and sensors under test shall be inhibited for the duration of the test except for
57. ime allowed after entry to the premises to Disarm the security system before the panel initiates an Alarm Transmission Sequence 3 2 26 entry exit zone a delayed zone on the perimeter of the protected premises 3 2 27 Exit Error a signal produced when an entry exit zone is still violated at the expiration of the Exit Time 3 2 28 Exit Time the period of time allowed after Arming a security system to exit the premises without tripping an alarm 3 2 29 false alarm an alarm transmission sent by the security system indicating the presence of an alarm condition when none exists SIA 2000 2009 All rights reserved Page 5 ANSI SIA CP 01 2007 3 2 30 fire alarm verification an operation that helps ensure that an alarm condition persists by resetting a tripped sensor in a fire zone and confirming that the sensor remained tripped or waiting for the sensor to re trip within a set period of time e g if a low power RF smoke detector is self resetting or auto restoring checking that the sensor trips more than once or remains tripped within a set period of time Fire alarm verification is meant to be a function of either the control panel or the sensor detector When fire alarm verification is a function of the control panel delaying transmission of the fire alarm signal after the initial sensor trip until a second sensor trip occurs within the confirmation period meets the SIA CP 01 requirements 3 2 31 fire zone
58. ions e Standards Committee Report 1994 1995 Central Station Alarm Association e 1994 Study of False Alarms Security Industry Association e Model Cities Executive Summaries Alarm Industry Research and Education Foundation AIREF This standard is intended to allow compliance with the following standards National Fire Protection Association e NFPA 72 National Fire Alarm Code Underwriters Laboratories Inc e UL609 Local Burglar Alarm Units and Systems e UL611 Central Station Burglar Alarm Systems e UL 681 Installation and Classification of Mercantile and Bank Burglar Alarm Systems e UL 864 Control Units for Fire Protective Signaling Systems SIA 2000 2009 All rights reserved Page 1 ANSI SIA CP 01 2007 e UL985 Household Fire Warning System Units e UL 1023 Household Burglar Alarm System Units e UL 1076 Proprietary Burglar Alarm Units and Systems e UL1610 Central Station Burglar Alarm Units e UL 1635 Digital Burglar Alarm Communicator System Units e UL 1641 Installation and Classification of Residential Burglar Alarm Systems 2 2 Supporting Documents The digital communications features detailed in this standard are supported by the Security Industry Association Digital Communication Standard SIA Format Protocol for Alarm System Communications 2 3 Precedence In the event of conflict between this standard and other reference documents mentioned herein the order of precedence shall be
59. is now restored In accordance with SIA DC 03 this signal is sent as BE Zone ID When SIA DC 05 is used this signal is sent as 3 377 Zone ID Page 46 SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 Annex H informative Common Nomenclature This annex describes the common nomenclature for Alarm Panels which manufacturers are encouraged to use Because many operators of alarm panels are required to manage several panels located in multiple locations Home work relatives etc it is desirable that the most common functions be named alike The following are the basic functions that may be named alike Disarm That portion of the system that is designed to detect unauthorized entry into the protected premises is not in use Other forms of protection may or may not be in use Cancel To transmit an additional alarm signal to a central station indicating that a prior signal is to be disregarded Arm That portion of the system that is designed to detect unauthorized entry into the protected premises is in use Other forms of protection may or may not be in use Premises Arm That portion of the system that is designed to detect unauthorized entry into the protected premises when there are inhabitants within and with the exception of the entry portal is in use Other forms of protection may or may not be in use No Entry Arm That portion of the system that is designed to detect una
60. is required to describe the operation of the abort feature 4 2 5 1 2 Consult with your installer to determine if your system is configured with a communicator delay A communicator delay will prevent a report to the central station if the control panel is disarmed within 30 45 seconds after an intrusion alarm is triggered Note that fire type alarms are normally reported without a delay Table 2 Quick Reference and User Manual Requirements Section Feature Quick Reference User Manual Requirements Requirements 4 2 2 1 Exit Time must document must document 4 2 2 2 Progress Annunciation must document if programmable must document 4 2 2 3 Exit Time Restart must document must document 4 2 2 4 Exit Error must document if programmable not required in user manual 4 2 2 5 Unvacated Premises must document must document SIA 2000 2009 All rights reserved Page 17 ANSI SIA CP 01 2007 4 2 2 6 Recent Closing must document if programmable not required in user manual 4 2 3 1 Entry Delay must document must document 4 2 3 2 Progress Annunciation must document if programmable must document 4 2 3 3 Disarm not required in quick reference must document 4 2 4 1 Control Buttons not required in quick reference must document 4 2 4 2 Manual Alarms not required in quick reference must document 4 2 4 3 Syst
61. ly to a central station 3 2 16 communicator delay a period of time which elapses before the control panel sends a transmission to the central station See Abort Window 3 2 17 control the part of the security system that determines the operation and interaction of the system based on programmed logic Page 4 SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 3 2 18 control panel the part of a security system that handles control and communication whether as combined or separate physical units 3 2 19 credential any piece of authoritative information that is related to a specific individual and can be used to identify them A credential is normally used to allow only authorized individuals the ability to gain admission through a portal in a facility 3 2 20 cross zoning a configuring of logic within the control panel such that two or more zones of the security system are interdependent in causing an alarm condition 3 2 21 delayed zone a zone or circuit configured to provide a time delay when tripped before an alarm is generated 3 2 22 Disarm to turn off a security system 3 2 23 double action trigger a manual operation that requires two simultaneous or sequential actions 3 2 24 Duress a duress signal is activated by a user when they feel threatened due to one or more persons trying to force the user to enter or re enter a premises 3 2 25 Entry Delay the period of t
62. n is activated the alarm panel emits a sound SIA 2000 2009 All rights reserved Page 47 ANSI SIA CP 01 2007 Annex informative System Configuration Identification Ref 4 6 1 1 Section 4 6 1 1 requires the manufacturer to identify the minimum equipment requirements for a compliant installation It does not imply that each component in the system be must be listed as CP 01 compliant For example consider a manufacturer that offers two types of keypads First they offer a 3100 series of LED keypads that do not support all CP 01 requirements Second they offer a 4100 series of keypads that has been listed and does meet support all CP 01 requirements The manufacturer must identify that a 4100 series keypad must be installed for CP 01 compliance but this does not prevent the additional use of 3100 series keypads in that same system Page 48 SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 Annex J informative Labelling Ref 4 4 2 Sensor and wiring requirements must be described so that sensor compatibility with the zone input characteristics of the panel is assured over the full range of operating conditions Different zone types may require different compatibility specifications but here is a hypothetical example for a supervised input Zone Input Specifications maximum loop current shorted loop 7 4 mA o maximum loop voltage open loop 5 0 VDC o loop shorted OV
63. of this standard CAUTION NOTICE This American National Standard may be revised or withdrawn at any time The procedures of the American National Standards Institute require that action be taken periodically to reaffirm revise or withdraw this standard Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute The developers of this standard have requested that holders of patents that may be required for the implementation of the standard disclose such patents to the publisher However neither the developers nor the publisher have undertaken a patent search in order to identify which if any patents may apply to this standard As of the date of publication of this standard and following calls for the identification of patents that may be required for the implementation of the standard no such claims have been made No further patent search is conducted by the developer or the publisher in respect to any standard it processes No representation is made or implied that licenses are not required to avoid infringement in the use of this standard Printed in the United States of America Published by The Security Industry Association 635 Slaters Lane Suite 110 Alexandria VA 22314 1177 SIA 2000 2009 All rights reserved Page ii SIA 2000 2009 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 Contents Page F
64. ontrol panel supports a silent exit feature and it has been invoked the Exit Time shall be doubled for that exit period only but shall not exceed two hundred and fifty five 255 seconds 4 2 2 2 Progress Annunciation The control panel shall annunciate a distinct pulsating audible sound throughout the duration of the Exit Time to warn person s still within the premises that the exit period is in process An audible annunciation whose pulsating rate is distinctly different shall sound during the last ten 10 seconds of the Exit Time to warn person s that the Exit Time is running out A control panel may meet this requirement by having two separate buttons for arming where one is arm normal with progress annunciation and one is arm silent no annunciation If the control panel supports a silent exit feature and it has been invoked the audible progress annunciation shall be silenced on one or more keypads for that exit period only The control panel shall not allow progress annunciation to be disabled for the entire system but may allow annunciation to be disabled for individual keypads 4 2 2 3 Exit Time Restart An option shall be provided where violation restoral and then a second violation of an entry exit zone prior to the end of the Exit Time shall restart the Exit Time The panel shall not allow the Exit Time to be restarted more than once The default setting for this option shall be that it is enabled Panels may have this fe
65. raft Document 13 March 2009 Shows all proposed changes vs current released standard american Nations S ed SS g Yn Sponsor The Security Industry Association Publication Order Number 14072 ANSI SIA CP 01 2009 DRAFT 13 March 2008 Copyright Notice Approval of an American National Standard requires verification by ANSI that the requirements for due process consensus and other criteria for approval have been met by the standards developer Consensus is established when in the judgment of the ANSI Board of Standards Review substantial agreement has been reached by directly and materially affected interests Substantial agreement means much more than a simple majority but not necessarily unanimity Consensus requires that all views and objections be considered and that effort be made toward their resolution The use of American National Standards is completely voluntary their existence does not in any respect preclude anyone whether he or she has approved the standards or not from manufacturing marketing purchasing or using products processes or procedures not confirming to the standards The American National Standards Institute does not develop standards and will in no circumstances give interpretation on any American National Standard in the name of the American National Standards Institute Requests for interpretations should be addressed to the secretariat or sponsor whose name appears on the title page
66. re allowed but not required o Terms such as is are will and others are used to convey statements of fact for advisory purposes only The annotation NOTE also precedes advisory information Where this standard is silent on a feature the feature is permitted so long as it is not in conflict with the requirements contained herein A requirement is a feature that the control panel must perform under all circumstances A required option is a programmable feature that must be in the control panel An allowed option is a programmable feature that is not required or prohibited by the standard An allowed feature is a non programmable feature that is not required or prohibited by the standard Normative Annexes contain binding information 3 2 Terms and definitions The terms and definitions listed below are for use within this standard in order to provide uniform use and understanding For common industry nomenclature of terms used in describing alarm panels and events please refer to Annex H 3 2 1 24 hour alarm an alarm produced by a trip on a 24 hour zone 3 2 2 24 hour zone a zone that is always active usually used for smoke detectors or other types of life safety initiating devices 3 2 3 abort a manual intervention after a system trip that prevents an alarm from being sent 3 2 4 abort window a period of time after a sensor initiated alarm condition that allows the user additional time to Disarm
67. sequence for call waiting cancel is typically lt 70 gt lt pause gt on a DTMF line but may vary depending on the region of the country To test this feature a DTMF test set may be used to confirm that the control can dial lt gt and all the digits on a standard DTMF phone Arm the UUT and wait till the Exit Time has expired Trip any zone and wait till an alarm transmission is started Verify by use of a standard dial verifier that the call waiting cancel sequence was sent before the dialed phone number When the UUT senses that a connection was not made verify that an alternative dialing method was employed Verify that a warning to installers not to use the call waiting cancel feature inappropriately is provided with the UUT Page 40 SIA 2007 All rights reserved DRAFT 13 March 2009 SECTION 5 INSTALLATION AND TEST to be performed on each partition of the UUT VALIDATION PROCEDURE VP 30 Quick Reference e Verify that a quick reference chart or card is provided with the UUT which details all programming locations for the features in the standard and their associated test procedures EOT VP 31 System Test e Verify that the UUT has a test feature which supports tests VP 32 through VP 37 below e Verify that the test feature may be independently activated for each partition of the UUT EOT VP 32 Initiation of Test e Arm the UUT and wait until the Exit Time is expired e Start a test sequence and
68. stallation may be subordinate to other UL requirements for the intended application Combined Entry Delay and Abort Window should not exceed 1 minute Page 22 SIA 2007 All rights reserved DRAFT 13 March 2009 Annex B informative ANSI SIA CP 01 2009 Arming Disarming and Transmission Sequences Exit Time Clause 4 2 2 1 Progress Annunciation Clause 4 2 2 2 2nd Violation of Entry Exit Zone Violated Entry Exit Zone Progress Annunciation Clause 4 2 3 2 Disarm Clause 4 2 3 3 SIA 2000 2009 Al Table B 1 System Arming and Exit Sequence Clause 4 2 2 45 to between 120 to 255 seconds Default 60 seconds During Exit Time Last 10 seconds of Exit Time During Exit Time Clause 4 2 2 3 End of Exit Time Clause 4 2 2 4 End of Exit Time Within 2 minutes of the end of the Exit Time Clause 4 2 2 6 Initiates Annunciation Progress Audible Annunciation Distinct Audible Annunciation May Restart Exit Time One Time Only Initiates Exit Error Sequence an Arms the Alarm System Transmit Recent Closing Time doubles if the silent exit feature is invoked Disabled if the silent exit feature is invoked Default Annunciate ON 2nd Violation violation restore violation of entry exit zone Option Shall Stay Arm if no exit was made during Exit Time Clause 4 2 2 5 Include user number in transmission if available
69. t no signal is sent Repeat VP 5 without Disarming the UUT Verify that the alarm is transmitted 60 seconds after the local alarm sounds Verify that the transmission includes the appropriate alarm code and an Exit Error VP 6 Unvacated Premises Verify that the UUT is defaulted with automatic Stay Arm unvacated premises enabled Arm the UUT Do not trip any entry exit zones during the Exit Time Verify that the UUT Arms in the Stay Arm mode VP 7 Recent Closing Arm the UUT Wait 107 seconds after the expiration of the Exit Time then trip any non fire non delayed zone Verify that a Recent Closing is transmitted along with the appropriate alarm code Verify that the transmission includes the appropriate user number when available Disarm the UUT Arm the UUT Wait 133 seconds after the expiration of the Exit Time then trip any non fire non delayed zone Verify that the UUT does not send a Recent Closing transmission or a user number along with the alarm code ENTRY DELAY Page 30 O SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 VALIDATION PROCEDURE VP 8 Entry Delay Verify that the UUT Entry Delay is defaulted for all entry exit zones that have a unique default settings to 30 seconds Arm the UUT and wait for the Exit Time to expire Trip an entry exit zone Verify that the time between the trip and the local alarm Entry Delay is 30 seconds Disarm the UUT Reprogr
70. the system before an alarm is transmitted 3 2 5 alarm a condition indicating a state of alert duress perimeter violation or fire at the premises SIA 2000 2009 All rights reserved Page 3 ANSI SIA CP 01 2007 3 2 6 alarm signal a transmission of an alarm condition or alarm report 3 2 7 annunciator a low level audio or visual device such as a speaker or LED whose purpose is to inform the system user the condition or status of the security system or designated part of the security system 3 2 8 Arm to turn on a security system 3 2 9 arming station the part s of a security system from which a human operator can manually Arm and Disarm the system manipulate the system operation or otherwise interact with the system 3 2 10 Away see Full Arm 3 2 11 Bell a specific tyoe of sounder which produces a ringing or gong sound through the striking of its hammer to its metal part 3 2 12 Cancel a transmission indicating that the previous alarm signal or alarm in process is to be disregarded 3 2 13 Close the act of Arming a security system 3 2 14 code a parcel of electronic data usually represented by a short series of letters or numbers corresponding to a specific event or status of the security system which is generated by the control panel and sent as a report or part of a report 3 2 15 communicator the part of the security system that sends electronic data outside the premises typical
71. the changes 9 11 2007 minutes 3 2 66 zone type CI J 4 2 2008 minutes 3 2 66 Rich Hinkson to revise zone type 10 29 2008 minutes 3 2 66 zone type es Er ro to add GE ea 3 9 2009 editing 3 2 66 zone type added _ 2n7n0sjema 4225 junvacated premises ADT Input 3 13 2009 editing 14 2 25 unvacated premises TN added 4 9 11 2007 minutes 46 1 quickreference DS discussed 4 2 2008 minutes 4 6 1 product doc table Sequel discussing Ted N to revise 10 29 2008 minutes 4 6 1 product documentation Sequel ltoadd ready to add AAA 3 9 2009 editing 4 6 1 product documentation 9 11 2007 minutesfannexD NLTL self validation ADT discussed 4 2 2008 3 9 2009 minutes editing annex D annex D ADT ftoada TN faddea NLTL self validation NLTL self validation 9 11 2007 minutes 3 2 2 24 hour alarm eee 4 2 2008 3 9 2009 minutes editing 3 2 2 3 2 2 eel slightly revised from committee added approved version TN 24 hour alarm 24 hour alarm 9 11 2007 minutes 3 2 9 arming station 4 2 2008 3 9 2009 9 11 2007 4 2 2008 3 9 2009 minutes editing minutes minutes editing 3 2 9 3 2 9 3 2 19 3 2 19 3 2 19 pr o ooo TN faded IDS agreed 4 IOS foad ON fadded arming station arming station credential credential credential 9 11 2007 minutes 3 224 duress IDS discussed 4 2 2008 3 9 2
72. there is no progress annunciation during the Exit Time Disarm and rearm the UUT Verify that Exit Time is annunciated VP 4 Exit Time Restart Arm the UUT During the Exit Time Trip an entry exit zone restore it then trip it again Verify that the time between the second trip of the entry exit zone and the start of the local alarm is 60 seconds Disarm the UUT Arm the UUT During the Exit Time Trip an entry exit zone restore it then trip it again Then restore the entry exit zone and trip it again Verify that the time between the second trip of the entry exit zone and the start of the local alarm is still 60 seconds Disarm the UUT If the UUT has a silent exit feature Arm the UUT with the silent feature During the Exit Time Trip an entry exit zone restore it then trip it again Verify that the time between the second trip of the entry exit zone and the start of the local alarm is 120 seconds SIA 2000 2009 All rights reserved Page 29 ANSI SIA CP 01 2007 VALIDATION PROCEDURE VP 5 Exit Error Arm the UUT Violate an entry exit zone and leave it violated through the entire Exit Time Verify that an Exit Error sequence commences at the end of the Exit Time with the following features The local alarm sounds The annunciator sounds an entry annunciation or an alarm condition An Entry Delay begins Disarm the UUT prior to the expiration of the Entry Delay and verify tha
73. to In order to allow the installer to match the operating ranges of sensors to the operating range of the control panel the panel shall specify on the interconnect label information that allows an installer to confirm compatibility between the panel zone inputs and the sensors selected for the installation An example is provided in Annex Annex J e 4 4 3 Restoration of Power last sentence refined to The panel arming state shall be retained no less than fourteen 14 days during a power loss e 4 5 Call Waiting DTMF test clarified e 4 6 1 Quick Reference Section expanded upon e 4 6 1 1 added section on System Configuration Identification e 4 6 3 System Test added A procedure outlined in the manuals is an acceptable alternative to a special mode of operation e 4 6 7 1 Automatic Termination added The test termination annunciation must be given whenever a test is terminated automatically regardless of the length of the test This would require that an automatic test termination could not take place in less than 5 minutes though the test can be terminated manually in less than 5 minutes Since the person testing the system is probably not going to be at the arming station at all times the annunciation should be audible e 4 6 7 2 State at Termination clarified The standard does not prohibit the annunciation and or the reporting of fire alarm trouble during a test mode e VP 7 added non delayed zone e
74. troke of the user code Verify that the system Disarms Arm the UUT and wait for the Exit Time to expire Trip an entry exit zone During the Abort Window enter an invalid user code Verify that Alarm Annunciation is silenced on the first keystroke of the invalid user code Verify that Alarm Annunciation resumes after the last digit of the invalid user code or after the time specified by the manufacturer Verify that the Abort Window is still 30 seconds VP 17 Abort Verify that the UUT is defaulted to annunciate that no alarm has been transmitted when the alarm is Aborted Arm the UUT and wait for the Exit Time to expire Trip a non fire type zone Disarm the UUT Verify that the UUT does not transmit an alarm Verify that the UUT annunciates that no alarm was transmitted VP 18 Alarm Transmission e Arm the UUT e Trip a non fire type zone e Verify that the UUT transmits the alarm 30 seconds after the local alarm sounds VP 19 Disarm Arm the UUT and wait for the Exit Time to expire Trip a zone and allow the system to report the alarm Disarm the UUT Verify that the UUT indicates an alarm has occurred and which zone was violated Page 34 O SIA 2007 All rights reserved DRAFT 13 March 2009 VALIDATION PROCEDURE VP 20 Cancel Window Arm the UUT and wait for the Exit Time to expire Trip a zone and allow the system to report the alarm Wait 4 minutes and 30 seconds after the transmission of the
75. tted during the Cancel Window if an alarm was previously transmitted Panel will indicate an alarm occurred and which violated zone s caused the alarm SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 Annex C informative Event Timing Diagrams The following event timing diagrams use the default panel settings as prescribed in the text of the standard The diagrams also assume that no commands are made to the panel during the sequence unless otherwise indicated Areas shown in grey are not defined by the standard and may be used as the manufacturer requires System Arm without violations Clause 4 2 2 1 and 4 2 2 2 TIME MIN SEC 00 50 1 00 SYSTEM STATE Unarmed Exit Time Armed ANNUNCIATOR Exit Annunciation LOCAL ALARM COMMUNICATION User Arms the Alarm System gt System Arm with multiple trips of the entry exit zone during Exit Time Clause 4 2 2 1 4 2 2 2 and 4 2 2 3 TIME MIN SEC 00 lt 1 00 00 50 1 00 SYSTEM STATE Unarmed Exit Time Restart Exit Time ANNUNCIATOR Exit Annunciation Exit Annunciation LOCAL ALARM COMMUNICATION User Arms the Alarm System 2 Exit Delay Restart occurs 1 time only at the trip after the 1st restoral of an entry exit zone System Arm with premises unvacated Clause 4 2 2 1 4 2 2 2 and 4 2 2 5 Entry exit zone untripped during Exit Time TIME MIN SEC 00 50 1 00 SYSTEM STATE Unarmed Exit Time Armed in the Stay Arm mod
76. tween the trip and the local alarm to time between the local alarm and the alarm signal correction Added Abort Window verification test for 46 seconds MARCH 2007 REVISION 2 1 Added UL 1076 to listing of Related Documents 3 1 5 Binding language added text clarification of requirements A requirement is a feature that the control panel must perform under all circumstances A required option is a programmable feature that must be in the control panel An allowed option is a programmable feature that is not required or prohibited by the standard An allowed feature is a non programmable feature that is not required or prohibited by the standard 3 2 Terms and definitions added text The terms and definitions listed below are for use within this standard in order to provide uniform use and understanding For common industry nomenclature of terms used in describing alarm panels and events please refer to Annex H 3 2 xx Credential definition added 3 2 xx Fire Alarm Verification definition refined 3 2 xx Fire Zone carbon monoxide added to the definition example 3 2 xx Remote Control Device definition refined 4 1 Partitioned Systems refined further 4 2 2 Arming and Exit further clarification on automatic arming 4 2 2 1 Exit Time minimum time and Silent Exit feature further clarified 4 2 2 2 Progress Annunciation added A control panel may meet this requirement by having two separate buttons for arming wh
77. uthorized entry into the protected premises when there are inhabitants within is in use Other forms of protection may or may not be in use Bypass A point of protection window door etc is temporarily disabled from performing its intended function Quick Bypass Upon exiting and wishing to Arm the system and a Point s is not in its intended position for Arming the panel will allow Arming with the Point s disabled from performing its intended function Duress When about to Disarm the system the user is approached by a would be perpetrator and the user uses a unique function which Disarms the system and transmits a Duress alarm to the monitoring center Police Emergency A user of the alarm system has observed a situation that requires police response and activates a unique function which transmits a Police Emergency alarm to the monitoring center Fire Emergency A user of the alarm system has observed a situation that requires fire department response and activates a unique function which transmits a Fire alarm to the monitoring center Medical Emergency A user of the alarm system has observed a situation that requires emergency medial assistance and activates a unique function which transmits a Medical Emergency alarm to the monitoring center Quick Arming An abbreviated or shorten function that Arms the system See Arm Monitor Mode The system in not Armed and any time a perimeter point of protectio
78. variations of primary and secondary power sources or due to complete loss of primary or secondary power or both 4 4 2 Labelling In order to allow the installer to match the operating ranges of sensors to the operating range of the control panel the panel shall specify on the interconnect label information that allows an installer to confirm compatibility between the panel zone inputs and the sensors selected for the installation An example is provided in Annex Annex J 4 4 3 Restoration of Power Upon the restoration of power after a complete loss of primary and secondary power the control panel shall resume operation in the same Arm state and with the same zones bypassed as when the panel lost primary and secondary power The panel shall disregard input from all sensors for a minimum of sixty 60 seconds from the time of the primary power restoration The panel arming state shall be retained no less than fourteen 14 days during a power loss 4 5 Call Waiting To help prevent a call waiting line from interfering with the alarm verification process causing the indication of a continuous ring when the phone line is actually in use a programmable option for call waiting cancel shall be Page 16 O SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 required on communicators that use media e g PSTN where call waiting may be provisioned The default setting for this option shall be that it is disabled S
79. w is defaulted for all non fire zones that have a unique default settings to 30 seconds Arm the UUT and wait till the Exit Time expires Trip a non fire zone Verify that the time between the local alarm and the alarm signal Abort Window is 30 seconds Disarm the UUT Reprogram the Abort Window to 14 seconds Note If the UUT did not accept programming to 14 seconds proceed to the next test Verify that the time between the local alarm and the alarm signal is 15 seconds or greater Disarm the UUT Reprogram the Abort Window to 15 seconds Verify that the time between the local alarm and the alarm signal is 15 seconds Disarm the UUT Reprogram the Abort Window to 45 seconds and verify that the time between the local alarm and the alarm signal is 45 seconds Disarm the UUT Reprogram the Abort Window to 46 seconds Note If the UUT did not accept programming to 46 seconds proceed to the next test Verify that the time between the local alarm and the alarm signal is 45 seconds or less Disarm the UUT Perform the above sequence for all non fire zones on the UUT EOT SIA 2000 2009 All rights reserved Page 33 ANSI SIA CP 01 2007 VALIDATION PROCEDURE VP 16 Disarm Program the UUT with a User Code Arm the UUT and wait for the Exit Time to expire Trip a non entry exit non fire zone During the Abort Window enter a user code Verify that Alarm Annunciation is silenced on the first keys
80. y test to it be UL listed for both a local and off premises reporting Any hardware device added to a system to meet the requirements of this standard needs to be UL listed or UL will test to verify that a failure of this device does not compromise the existing UL requirements of the system SIA 2000 2009 All rights reserved Page 43 ANSI SIA CP 01 2007 Annex F informative Clarifications on Effectivity The following is being provided as informative clarifications for the effectivity of changes made to ANSI SIA CP 01 F 1 Revisions of CP 01 will not contain changes that significantly affect the false alarm performance of the listed products F 2 Anew edition of CP 01 is required when changes will significantly affect the false alarm performance of the listed products F 3 The Subcommmittee votes on whether or not any planned update of CP 01 would be defined as a revision F 4 Effectivity for revisions F 4 1 Effective on completion of the ANSI process F 4 2 Review of listed products to the latest revision is triggered if a product with modifications potentially affecting CP 01 compliance are submitted for UL for review an example would be introduction of a new style panic buttons otherwise CP 01 re listing is not required F 4 3 New product submittals will be evaluated under the latest published CP 01 standard F 5 Effectivity for new editions F 5 1 Effective one year after completion of the ANSI canvass pro
81. y that there is no local alarm and that no alarm has been transmitted e If the feature is available verify that 2 error transmissions were made that report the unverified trips in a cross zone e Disarm and rearm the UUT e Program two zones in a cross zoned arrangement e Arm the UUT and wait until the Exit Time is expired e Trip one of the zones that are programmed as a cross zone e During the cross zone time trip the other zone in the cross zone pair e Verify that the Alarm Transmission Sequence local alarm starts at the second trip Page 36 SIA 2007 All rights reserved DRAFT 13 March 2009 ANSI SIA CP 01 2009 VALIDATION PROCEDURE REFERENCE VP 24 Swinger Shutdown Not required for fire alarms 4 3 2 e Arm the UUT and allow the Exit Time to expire e Trip a zone and allow the accompanying alarm to be reported e Wait for the local alarm to reset then trip the same zone again e Verify that the system does not go into alarm If the UUT supports two trip Swinger Shutdown e Arm the UUT and allow the Exit Time to expire e Trip a zone and allow the accompanying alarm to be reported e Wait for the local alarm to reset then trip the same zone again e Wait for the local alarm to reset then trip the same zone a third time e Verify that the system does not go into alarm SIA 2000 2009 All rights reserved Page 37 ANSI SIA CP 01 2007 VALIDATION PROCEDURE REFERENCE