Conforming Meter Framework Itron SENTINEL® Issue 2.0
Contents
1. Alarm Task v Meter Type v Issue 2 0 February 1 2012 Public D 3 Appendix D Sample MIRT File Screen Images for the Itron SENTINEL Meter IESO STD 0066 z Metering Installation Registration Tool File Help Customer Information Recorder Information Recorder Remote Interrogation Meter Channel Information Recorder ID Location Device Type Local Phone No 9051234567 1234H Daisy Chain No Master Slave Remote Phone No 33 ID of Master in Chain Baud Rate 2400 ID of Next Slave in Chain Phone Password 1 Answer Window Time to Phone Password 2 Answer Window Days Portable Reader Password CD345678901234567890 Unit Address I General Help Use this form to enter phone number password and daisy chain information for the meter Include the area code in the local phone number for example 4162123904 In this example both the Phone Password 1 and the Phone Password 2 fields are shown in red The MIRT software expects both the Phone Password 1 and Phone Password 2 fields to be completed before saving the file However MV 90 requires that the SENTINEL meter s Secondary security code as defined in the PC PRO Advanced meter programming software to be stored in the Portable Reader Password field in order to handle its maximum 20 character length in a single string The IESO will use the Secondary security code to obtain read access to the meter with
2. February 1 2012 Program Value IMO SAMPLE FILE 3 EL SENTINEL 3234 None SS4AAL 20A 3EL 120 480V Ks 3 6 x1 MM KYZ 0 05 4Q 2005 01 18 6 00 53 PM 2005 03 17 7 14 31 AM Rolling Demand No No No No No Transformer Rated N SII 3 gt None selected Public C 1 Appendix C Sample Itron PC PRO Advanced Program Listing for the Itron SENTINEL Meter Quantity Selections Energy Registers Energy Register 5 Energy Register 6 Energy Register 7 Energy Register 8 Demand Registers Demand Register 1 Demand Register 2 Demand Register 3 Demand Register 4 Demand Register 5 Demand Register 6 Demand Register 7 Demand Register 8 Demand Register 9 Demand Register 10 Display Configuration Display Options Display Scroll On Time Meter Rating Enable EOI Enable Load Indicator Enable Nominal Voltage Indicator Enable Phase Indicator Missing Phase Indicator Display Tool Box at Power Up Displayable Errors Clock TOU Error Reverse Power Flow Load Profile Error Full Scale Overflow IESO STD 0066 Unassigned Unassigned max Wd var d max W d max W r max var d W d max var d Unassigned Unassigned 7 Seconds Secondary Yes No Yes Blink Public Issue 2 0 February 1 2012 Conforming Meter Framework Appendix C Sample Itron PC PRO Advanced Program Listing for the Itron SENTINEL Meter Item 6 Item 7 Item 8 Item 9 Item 10 Item 11 Item 12 Item 1
3. field for an Itron SENTINEL meter must be unique start with the letter S and consist of an alphanumeric string that is at least seven 7 characters in length and no more than 15 characters in length To prevent duplication within the IESO s MV 90 database many MSPs have successfully created unique Meter IDs by concatenating the letter S with the meter s inspection or badge number For example if AB Hydro s normal meter inspection number is ABH12346 they would create a Meter ID of SABH12346 when programming the Itron SENTINEL meter 4 Public Issue 2 0 February 1 2012 Conforming Meter Framework 3 Meter Specific Issues Similar to the Itron QUANTUM Q1000 meter the Itron SENTINEL meter s internal energy registers record energy accumulation in base units of Wh and VARh These registers can be displayed in base units kilo units or mega units on the meter s six digit LCD display Special consideration must be given to this issue when MSPs are programming the meter and creating MIRT files for interrogating this meter with MV 90 The IESO strongly recommends that the SENTINEL meter s display for the Wh delivered and received and VARh delivered and received registers be programmed to show these register values in kilo units kWh kVARh with a length of 6 digits to maintain consistency with the way this data is reported by MV 90 However unlike the Itron QUANTUM Q1000 meter the Itron SENTINEL meter
4. Issue Reason for Issue Date 1 0 Initial release of Meter Framework document for the Itron SENTINEL meter March 25 2008 2 0 Update to document February 1 2012 Issue 2 0 February 1 2012 Public Table of Contents IESO STD 0066 Document Control Authorities Prepared by Role Signed amp Dated Barry Spencer Assistant Engineer Technical Officer Metering Installation Owned by Role Signed amp Dated Richard Zaworski Section Head Metering Installation Reviewed by Role Signed amp Dated Herb Osborne Technical Officer Metering Installation Approved by Role Signed amp Dated Kim Warren as per Chief Operating Officer Richard Zaworski Public Issue 2 0 February 1 2012 Conforming Meter Framework Table of Contents Table of Contents Table ot Cot nl Ss BEBE u R Ma HEHE N SE REH ERA GA i Li SL O FIQUICS LABAG NAA AA HEKA HEWE AA ii LiSEOfTAD 8 ici NANANA NAN Tank n na Tank n n Tan baw Tank n n Ta buk sk a ak n w ua NANANA iii Ta bl amp f GhAnd Sxy 2x 5ik y er henaka keka reka le keneke Hek nuk E Bek OS He Ka HURE Se EREN ANAN iv Ase eno o3 i 0 E PARADA BRAD rrr 1 2 IESO MV 90 System Configuration ccccccceseeeseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 2 2 1 MV 90 UOM Codes ee 2 3 Meter Specific ISSUCS LanG k ya NE RAY MASE NE H R RE
5. s internal encoded energy registers do not rollover for all practical purposes The internal registers will continue to accumulate energy independent of the rollover condition of the meter s physical display registers The Itron SENTINEL meter s display registers are limited to a maximum display of six digits and will rollover based on the settings that are programmed into the meter using PC PRO Advanced The IESO recommends programming the SENTINEL meter s Normal display to show the Wh delivered VARh delivered Wh received and VARh received registers in kilo units to maintain consistency with the units the IESO s MV 90 system uses for storing the SENTINEL meter s internal encoded energy register readings MV 90 reads the Itron SENTINEL meter s internal encoded energy registers when it interrogates the meter and by default without any Config file statements returns the internal encoded energy register value in kilo units Itron Canada Technical Support confirmed on January 18 2005 that the Itron SENTINEL meter s internal encoded energy registers do not rollover until they accumulate 2 or 1 8 x 10 Wh Thus the meter s internal encoded registers will not rollover in the normal six year seal life of a meter For this reason the IESO requires all MSPs to use a default value of 9 in the Number of Dials field in the MIRT file for Channels 1 to 4 for the Itron SENTINEL meter MV 90 presently requires the value ente
6. Channel Delete Current Channel Channel Copy Meter Serial Number ABH12346 Maximum Total Energy Meter Multiplier 15800 Minimum Total Energy Pulse Multiplier p 42 Maximum Interval Demand Power Flow Direction Received 7 Minimum Interval Demand Pulse Offset Zero Interval Tolerance Unit of Measurement Code o x Load Factor Tolerance Redundant Meter Channel Power Factor Tolerance Ka Redundant Channel Tolerance amp Change Between Interyal General Help Tolerance Check f100 PT CT Ratio Service Type wye Register Type E R Number of Dials Jg Encoder Type 03 KVA Set Number 2 Omit On Upload Use this form to set up and edit information for each channel in the meter The middle column of fields only accepts input when the Meter Type is standalone and is grayed out for other meter types D 8 Public Issue 2 0 February 1 2012 Conforming Meter Framework Appendix D Sample MIRT File Screen Images for the Itron SENTINAL Meter Metering Installation Registration Tool File Help Customer Information Recorder Information Recorder Remote Interrogation Meter Channel Information Recorder ID _f100007891 Customer ID Current Logical Channel Append New Channel Insert New Channel Delete Current Channel Channel Copy Meter Serial Number ABH12346 O Maximum Total Energy Tolerance Check 700 Meter Multiplier hesena tt Minimum Total Energy an PT CT Rati
7. Images for the Itron SENTINAL Meter The IESO has experienced meter registration difficulties when MSPs create MIRT files using their own MV 90 system and include a config file name in the TIM Config File field located on the More tab of the Recorder data record For any MSP that chooses to create a MIRT file using their own MV 90 system to export a MIRT file rather than composing the MIRT file using the MIRT software it is imperative that the TIM Config File field be blank within the MIRT file submitted to the IESO Failure to do this will result in the MSP being assessed with a Meter Registration Error The IESO is presently modifying its internal MIRT file review process to verify this field is blank and will not accept any MIRT file that contains a non blank TIM Config File field When incoming MIRT files are discovered with characters in the TIM Config File field the IESO will not process the MIRT file and will request the MSP to submit a replacement MIRT file amp Master File Maintenance x File Edit Navigate Search Help tol Elma 417 3 1000078911 ABH12346 Recorder More Comm Plugging Route Inputs Relays f Suppl TIM Number 30 G3 Daisy Chain NG Master Slave x Device Follows DST Master ID LOP Option w a Time Zone Adjust ao Auto Timeset 7 Battery Install 0000 00 00 T Memory Size Kb 55 Days On Batey TIM Config File Min On Battery
8. No field Issue 2 0 February 1 2012 Public D 5 Appendix D Sample MIRT File Screen Images for the Itron SENTINEL Meter IESO STD 0066 Metering Installation Registration Tool File Help Customer Information Recorder Information Recorder Remote Interrogation Meter Channel Information Recorder ID Customer ID Current Logical Channel 1of4 Append New Channel Insert New Channel Delete Current Channel Channel Copy Meter Serial Number ABH12346 Maximum Total Energy Tolerance Check 100 Meter Multiplier 168800 oO Minimum Total Energy Ce PT CT Ratio Ez Pulse Multiplier jna2 oo Service Type wye gt Power Flow Direction Delivered gt Minimum Interval Demand T77 Register Type E Pulse Offset 0 T7 Zero Interval Tolerance Number of Dials g Unit of Measurement Code n x Load Factor Tolerance Encoder Type jor Redundant Meter Channel EE Power Factor Tolerance KYA Set Number AA o Change Between Intervals Omit On Upload General Help Use this form to set up and edit information for each channel in the meter The middle column of fields only accepts input when the Meter Type is standalone and is grayed out for other meter types The Number of Dials field for Channels 1 to 4 should always be 9 This field represents the maximum number of digits that the Itron SENTINEL meter s internal encoded register readings will be stored in by MV 90 before MV 90 interprets
9. the MIRT file Table 2 Itron SENTINEL Meter Load Profile Configuration 1 Settings 3 Phase 4 Wire 3 Element Meter or 3 Phase 3 Wire 2 Element Meter Parameter Value Storage Capacity Minimum value set to 2 880 intervals 10 days of 5 minute intervals Interval Length 5 Minutes 12 intervals hr Load MV 90 Default Channel Parameters Profile Recorded Ke UOM Register Encoder Meter Pulse Channel Value Value Code Type Type Multiplier Multiplier 1 kWh delivered 0 025 01 E 01 PT CT PT CT Ke 1000 2 kVARh delivered 0 025 03 E 02 PT CT PT CT Ke 1000 3 kWh received 0 025 01 E 03 PT CT PT CT Ke 1000 4 kVARh received 0 025 03 E 04 PT CT PT CT Ke 1000 5 Unconnected Unused 42 6 Unconnected Unused 42 7 Unconnected Unused 42 8 Unconnected Unused 42 The minimum IESO REQUIREMENT for both 3 element meters and 2 element meters for channels 1 4 is as indicated above For additional details please refer to the sample 3 element PC PRO Advanced program listing provided in Appendix C Issue 2 0 February 1 2012 Public 3 Meter Specific Issues 10 3 3 IESO STD 0066 Itron SENTINEL Meter Security Code Setup The Itron SENTINEL meter must be programmed to use passwords in accordance with the requirements specified in section 5 4 2 of the Wholesale Revenue Metering Standard Hardware This functionality is referred to as Security C
10. 12 Public 13 3 Meter Specific Issues IESO STD 0066 This page intentionally left blank End of Section 14 Public Issue 2 0 February 1 2012 Conforming Meter Framework Appendix A Calculation of the Practical MV 90 Energy Register Rollover Value for the Itron SENTINEL Meter Appendix A Calculation of the Practical MV 90 Energy Register Rollover Value for the Itron SENTINEL Meter Unlike the Itron QUANTUM Q1000 meter the Itron SENTINEL meter s internal encoded energy registers do not rollover for all practical purposes The internal encoded energy registers will continue to accumulate energy independent of the rollover condition of the meter s physical display registers The Itron SENTINEL meter s display register s are limited to a maximum display of six digits on the meter s LCD display and these registers will rollover based on the settings that are programmed into the meter using PC PRO Advanced MV 90 reads the Itron SENTINEL meter s internal encoded energy registers when it interrogates the meter and by default returns the register value in kilo units Notional register rollover values for this meter were investigated as shown below during the development of this document Based on this review the IESO has determined that the default value to be used in the Number of Dials field in MIRT files for channels 1 to 4 for all SENTINEL meters is 9 Projected Maximum Energy Register Accumulation O
11. 3 Item 14 Item 15 Item 16 Item 17 Item 18 Item 19 Item 20 Item 21 Item 22 Item 23 Item 24 Item 25 Item 26 Item 27 Item 28 Item 29 Item 30 Item 31 Item 32 Alternate Display Item 1 Item 2 Item 3 Item 4 Item 5 Item 6 Item 7 Item 8 Item 9 Item 10 Item 11 Item 12 Item 13 Item 14 Item 15 Item 16 Item 17 Item 18 Item 19 Item 20 Issue 2 0 February 1 2012 max W d max var d max W r max var r Current Date Current Time Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Segment Test ins W ins var ins VA Vec ins PF Minutes on Battery Firmware Revision Software Revision Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Public Appendix C Sample Itron PC PRO Advanced Program Listing for the Itron SENTINEL Meter C4 Item 21 Item 2 ID Item 3 ID k Item 4 ID ltem 5 ID Item 6 ID Item 6 Format Item 7 ID Item 7 Format Item 8 ID Item 8 Format Item 9 ID Item 9 Format Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned Unassigned max var r Unassigned Unassigned Unassigned Unassigned Unassigned Unassign
12. Document Issue 2 0 February 1 2012 Public References 1
13. ERA W W SURE K k V WEHE RA S R VER YA 4 3 1 Meter Manufacturer s Programming Software EEE 4 3 2 Meter Programming Requiremen S Eke 4 3 2 1 Power Outage Length Definition E EEE 8 3 3 Itron SENTINEL Meter Security Code Setup EEE U UUU 10 3 4 MV 90 OpekaliOfiSi AA ease eee le sakes 11 3 5 Interval Data and Channel Data Status Codes EEE EU 12 3 6 Meter Event C OQd eS dik ceed hotels hate hits Cove det AA tee denied le 13 Appendix A Calculation of the Practical MV 90 Energy Register Rollover Value for the Itron SENTINEL Meter A 1 Appendix B Minimum Pulse Weight Calculations for Load Profile Channels of the Itron SENTINEL Metel cccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeees B 1 Appendix C Sample Itron PC PRO Advanced Program Listing for the ltron SENTINEL Meter AA C 1 Appendix D Sample MIRT File Screen Images for the Itron SENTINEL M L BABA AE AA D 1 Referentes inmsin eaaa nal mun k Kal H n E n l sun b nal kund V uns nad ada d dad 1 Issue 2 0 February 1 2012 Public i List of Figures IESO STD 0066 List of Figures Figure 1 Typical Socket Meter for the Itron SENTINEL Melter EEEEEEEEEEUE U EEE 1 ii Public Issue 2 0 February 1 2012 Conforming Meter Framework List of Tables List of Tables Table 1 IESO Items of Interest within PC PRO Advanced Progr
14. PUBLIC a CC lt a 2 lt Y Conforming Meter Framework Itron SENTINEL Issue 2 0 Public Disclaimer The information on the Itron SENTINEL meter configuration parameters are provided as is without any warranties of any kind and the Independent Electricity System Operator IESO makes no representation and disclaims all express and implied warranties and conditions of any kind including without limitation representations warranties or conditions regarding accuracy timeliness completeness non infringement merchantability or fitness of that information for any particular purpose The IESO assumes no responsibility to you or any third party for the consequences of any errors or omissions in that information The IESO is not liable to the user of this information for any revisions to this information or to any third party for any damages of any kind arising out of or relating to the use of this information including but not limited to any lost profits lost opportunities special incidental indirect consequential or punitive damages even if the IESO is advised of such possibility These are conditions of delivery of this information Document ID IESO_STD_0066 Document Name Conforming Meter Framework Meter Type Itron SENTINEL Issue Issue 2 0 Reason for Issue Revised document to update content Effective Date February 1 2012 Conforming Meter Framework Document Change History Table of Contents
15. a register rollover By default MV 90 returns the encoded energy register readings for all Itron SENTINEL meters in kilo units The Register Type field should always be set to E for Encoder for Channels 1 to 4 of a MIRT file for the Itron SENTINEL meter Also the Encoder Type field MUST be set to 01 for Channel 1 02 for Channel 2 03 for Channel 3 and 04 for Channel 4 The Redundant Channel Tolerance field is now set to 0 by default for all channels in the MIRT tool MSPs creating MIRT files using MV 90 should set this value to 0 as well for all channels The IESO is now using MV STAR to complete an hourly validation of the interval data in the Conforming Main vs Alternate meters For additional details please refer to Appendix B 3 of Market Manual 5 2 Meter Data Processing The MIRT tool also sets a default a value of 900 000 into the Maximum Interval Demand field for all channels After a meter has been registered and the IESO has a reasonable period of actual interval data to review IESO process includes adjusting the Maximum Interval Demand values for channels to 4 of the Main and Alternate meters based on validation principles The next three screenshots show the meter information for channels 2 3 and 4 D 6 Public Issue 2 0 February 1 2012 Conforming Meter Framework Appendix D Sample MIRT File Screen Images for the Itron SENTINAL Meter Metering Inst
16. a status codes MV 90 properly returns and identifies the following types of standard interval data and channel data status codes from this meter Table 4 Standard MV 90 Interval Data and Channel Data Status Codes Returned from the Itron SENTINEL Meter and Corresponding PC PRO Advanced Standard Load Profile Status Codes Interval MV 90 Status Code Definition Power Outage IESO MTR Automatically Generated When Detected Itron SENTINEL Meter Standard Load Profile Status Code Displayed within PC PRO Advanced PC PRO Advanced Standard Load Profile Status Code Definition Outage Interval Short Interval Short Interval Interval Long Interval Long Interval Interval Time Reset Time Adjust Interval Clock Error Clock Error Interval RAM Checksum Error Checksum Error Channel Pulse Overflow Overflow Interval Test Mode Test Mode All interval data and channel data status codes that do not result in automatic MTRs are reviewed daily by IESO staff to determine whether a manual MTR should be issued The IESO s procedure for checking interval status codes with MV 90 is summarized in detail in Market Manual 5 2 Meter Data Processing Appendix B Validation Tests for Metering Installations section B 3 Tests Required Please refer to this document for additional details The standard load profile interval data status codes
17. allation Registration Tool File Help Customer Information Recorder Information Recorder Remote Interrogation Meter Channel Information Recorder ID 17291 Customer ID Current Logical Channel Append New Channel Insert New Channel Delete Current Channel Channel Copy Meter Serial Number ABH12346 Maximum Total Energy um MA Meter Multiplier fiss00 o Minimum Total Energy essa Pulse Multiplier 042 Maximum Interval Demand Power Flow Direction Delivered Minimum Interval Demand 7 Pulse Offset 7 Zero Interval Tolerance Unit of Measurement Code 03 Load Factor Tolerance Redundant Meter Channel EN Power Factor Tolerance Redundant Channel Tolerance fo Eep enlie General Help Tolerance Check fioo PT CT Ratio Service Type wye Register Type E B Number of Dials Jg Encoder Type o2 KVA Set Number f Omit On Upload f Use this form to set up and edit information for each channel in the meter The middle column of fields only accepts input when the Meter Type is standalone and is grayed out for other meter types Issue 2 0 February 1 2012 Public Appendix D Sample MIRT File Screen Images for the Itron SENTINEL Meter Metering Installation Registration Tool File Help IESO STD 0066 Customer Information Recorder Information Recorder Remote Interrogation Meter Channel Information Recorder ID Customer ID Current Logical Channel Append New Channel Insert New
18. ams for the Itron SENTINELO M l f ma k dalan IA NN AGA AN 6 Table 2 Itron SENTINEL Meter Load Profile Configuration 1 Settings 3 Phase 4 Wire 3 Element Meter or 3 Phase 3 Wire 2 Element Meter 9 Table 3 Itron SENTINEL Security Code Definitions anaanananananwwwaaaaannnnsanann 10 Table 4 Standard MV 90 Interval Data and Channel Data Status Codes Returned from the Itron SENTINEL Meter and Corresponding PC PRO Advanced Standard Load Profile Status Codes eenn a e EA Aa a AA e A E EAA EE AELA I 12 Issue 2 0 February 1 2012 Public iii Table of Changes IESO STD 0066 Table of Changes Reference Section and Paragraph Description of Change Version 2 0 document revised to update content Public Issue 2 0 February 1 2012 Conforming Meter Framework 1 Introduction 1 Introduction The Independent Electricity System Operator IESO has prepared this document to assist Meter Service Providers MSP and Metered Market Participants MMP with the configuration of new conforming meters in a manner that enables efficient registration of the meter into the IESO s MV 90 system supplied by Itron A secondary purpose is to improve the reliability of daily communication with each registered wholesale meter RWM by sharing the IESO s experience with different types of meters modems their configuration and ongoing performance reliabili
19. de 10 must be in units of Ph pulse Some conforming meters offer load profile programming options that specify pulse weights for UOM codes 01 and 03 in base units per pulse i e Wh pulse and VARh pulse The MSP preparing the MIRT file submission must ensure that all pulse weight units are properly converted into the format required by the IESO s MV 90 system at the time they create the MIRT file If the units for the pulse weight as submitted are not dimensionally correct with the UOM codes MV 90 will not properly convert the pulse data into engineering units Metering Installation Registration Tool File Help Customer Information Recorder Information Recceder Remote Interrogahon Mater Charnel Information Recorder ID Customer ID Curerk Local Channel J ias o Append New Charnel Insert New Channel Delete Current Channel Channel Copy Meter SerialNumber agH12346 Madum TotalEnegp O Toletance Check 4 100 Meter Mukipbee iga 7C Minimum Teta Energy SCAT Ratio Maximum rerval Demand yyy TT Serce T pe we v Power Flow Directon Devered v Minimum Irterval Demand RegiterType E gt Puze Offset jT Zero Interval Tolerance Number of Disks 5 Una of Measurement Code n Load Factot Tolerance EX Encode Type for Redundant Meter Channel Power Factor Tolerance KVA Set Number i Redundant Chanel Toleance X E Change Between Intervals Ont On Upload General Helo ee The middie cokan of fields only accepts i
20. easurement Device Multipliers Register Multiplier 1 0 CT Ratio 1 0 The Itron SENTINEL meter must be programmed to record true secondary values No loss adjustments or correction calculations are allowed to be calculated in the meter VT Ratio 1 0 The Itron SENTINEL meter must be programmed to record true secondary values No loss adjustments or correction calculations are allowed to be calculated in the meter Display Date Format YY MM DD Recommended to maintain consistency with IESO s Configuration MV 90 system parameters Normal Display kWh del kVARh del kWh rec kV ARh rec The meter s display should be programmed to show the current contents of each of these energy registers in kilo units with a display of 6 digits This will maintain consistency with the default format MV 90 uses to store energy register readings taken from the Itron SENTINEL meter The Itron SENTINEL meter s internal encoded energy registers store values in base units Wh VARh etc Program Section Item IESO Setting Comments Public Issue 2 0 February 1 2012 Conforming Meter Framework 3 Meter Specific Issues Load Profile Interval Length 5 Minutes Configuration Storage Capacity Must be gt 10 days Meter must be configured to store at least 10 days of 2 880 intervals 5 minute interval data Meter can be ordered with either 48 kB or 96 kB of RAM L
21. ed Unassigned Unassigned IESO_STD_0066 k _ oo para 32 15 xxxx xx Units Annunciator No Leading Zero 35 xxxx xx Units Annunciator No Leading Zero 16 xxxx xx Units Annunciator No Leading Zero 36 xxxx xx Units Annunciator No Leading Zero Public Issue 2 0 February 1 2012 Conforming Meter Framework Appendix C Sample Itron PC PRO Advanced Program Listing for the Itron SENTINEL Meter Item 10 ID 90 Item 10 Format Text Field Item 11 ID 91 Item 11 Format Text Field Item 12 ID 0 Item 12 Format Text Field Item 13 ID 0 Item 13 Format Text Field Item 14 ID 0 Item 14 Format Text Field Item 15 ID 0 Item 15 Format Text Field Item 16 ID 0 Item 16 Format Text Field Item 17 ID 0 Item 17 Format Text Field Item 18 ID 0 Item 18 Format Text Field Item 19 ID 0 Item 19 Format Text Field Item 20 ID 0 Item 20 Format Text Field Item 21 ID 0 Item 21 Format Text Field Item 22 ID 0 Item 22 Format Text Field Item 23 ID 0 Item 23 Format Text Field Item 24 ID 0 Item 24 Format Text Field Item 25 ID 0 Item 25 Format Text Field Item 26 ID 0 Item 26 Format Text Field Item 27 ID 0 Item 27 Format Text Field Item 28 ID 0 Item 28 Format Text Field Item 29 ID 0 Item 29 Format Text Field Item 30 ID 0 Item 30 Format Text Field Item 31 ID 0 Item 31 Format Text Field Item 32 ID 0 Item 32 Format Text Field Alternate Display Format Item 1 ID 888 Item 1 Format Text Field Ite
22. er Load profile channel pulse weights K used for the Itron SENTINEL meter must be selected from a range of PC PRO Advanced supported values for this meter between 0 025 and 800 000 unit hours per pulse in increments of 0 025 The channel pulse weights must also be selected in a manner that limits the allowable maximum number of pulses per 5 minute interval to 32 766 to comply with an MV 90 limitation The IESO has adopted 0 025 unit hours per pulse as its standard pulse weight for the Itron SENTINEL meter for UOM codes 01 and 03 Alternate Meters The following calculations demonstrate that a pulse overflow condition within MV 90 is highly unlikely for a SENTINEL meter when it is used in a typical IESO wholesale metering installation Calculations of Minimum Internal Pulse Weights for Programming Itron SENTINEL Meters Case 1 Watthours 3 Element Meter 3 Phase 4 Wire Load with CT current of 7 5 A 150 of Nominal Limit MV 90 Restricted Meter Pulse IESO Power Ho of Interval Energy per Limit per Calculated STANDARD aag barya Factor Phases Length eng Interval W min Pulse Weight min i A Projected maximum number of pulses per interval base on IESO STANDARD pulse weight 10 500 Case 2 Watthours 2 Element Meter 3 Phase 3 Wire Load with CT Current of 7 5 A 150 of Nominal Limit MV 90 Restricted Meter Pulse IESO Power Ho of Interval Energy per Limit per Calculated STANDARD Voltage Current Factor Phas
23. es rey pong Interval Ke Bili Pulse Weight Vv A h Projected maximum number of pulses per interval base on IESO STANDARD pulse weight 7 000 NOTE Unlike the Itron QUANTUM Q1000 meter the smallest available pulse weight supported by the SENTINEL meter is 0 025 Wh pulse Note The units of measure WITHIN the Itron SENTINEL meter for UOM 01 and 03 are base units not kilo units of Watthours Wh and VARhours V ARh Issue 2 0 February 1 2012 Public B 1 Appendix B Minimum Pulse Weight Calculations for Load Profile Channels of the Itron SENTINEL Meter IESO STD 0066 This page intentionally left blank End of Section B 2 Public Issue 2 0 February 1 2012 Conforming Meter Framework Appendix C Sample Itron PC PRO Advanced Program Listing for the Itron SENTINEL Meter Appendix C Sample Itron PC PRO Advanced Program Listing for the Itron SENTINEL Meter The following sample program listing was produced using Itron PC Pro Advanced for with IESO recommended settings for a 3 Element Alternate meter 4 Channel with internal modem PC PRO Advanced ltem Description Program Name Program ID Measurement Sublevel Description Date Created Date Modified Device Operation Demand Calculation Demand Only Meter Enable Voltage and Current Enabled Totalized Registers Device Multipliers Multiplier Type Register Full Scale Time of Use Selection TOU Schedule ID Issue 2 0
24. hould be used to document this information to ensure the incoming MIRT file review process can be completed efficiently and accurately For Alternate Meters where the MIRT file does not contain the connected CT and PT ratios the MSP should confirm the connected CT and PT ratio in the body of the e mail message as well The example shown in this appendix is for a 3 element Itron SENTINEL meter that has been programmed for use as an Alternate meter 4 channel in the IESO markets The instrument transformer ratios used for developing the screen images in this example are PT ratio of 16800 120 140 and CT ratio of 600 5 120 Metering Installation Registration Tool ii Recorder Information Recorder Remote Interrogation Meter Channel Information CustomerID 1000078911 Total Number of Logical Channels 4 Group Iz o Biling Cycle 5 T7 Interrogation Cycle Address1 Street 123 SPECIFICST O Address2 CITY ON General Help Use this form to enter the IMO Meter Point ID the facility address and contact information for the metering installation Place your cursor over a field box to display a short description of the field Click Help for more detailed information about the fields and using MIRT The Customer Name Field must be populated with the meter point s circuit description as shown in the example above Issue 2 0 February 1 2012 Public D 1 Appendix D Sample MIRT File Screen Image
25. m 2 ID 10 Issue 2 0 February 1 2012 Public C 5 Appendix C Sample Itron PC PRO Advanced Program Listing for the Itron SENTINEL Meter Item 2 Format Item 3 ID Item 3 Format Item 4 ID Item 4 Format Item 5 ID Item 5 Format Item 6 ID Item 6 Format Item 7 ID Item 7 Format Item 8 ID Item 8 Format Item 9 ID Item 9 Format Item 10 ID Item 10 Format Item 11 ID Item 11 Format Item 12 ID Item 12 Format Item 13 ID Item 13 Format Item 14 ID Item 14 Format Item 15 ID Item 15 Format Item 16 ID Item 16 Format Item 17 ID Item 17 Format Item 18 ID Item 18 Format Item 19 ID Item 19 Format Item 20 ID Item 20 Format Item 21 ID Item 21 Format Item 22 ID Item 22 Format Item 23 ID Item 23 Format Item 24 ID Item 24 Format Item 25 ID Item 25 Format Item 26 ID Item 26 Format Item 27 ID IESO STD 0066 xxxx xx Units Annunciator No Leading Zero 30 xxxx xx Units Annunciator No Leading Zero 40 xxxx xx Units Annunciator No Leading Zero 50 xxxx xx Units Annunciator No Leading Zero 92 Text Field 93 Text Field 94 Text Field 0 Text Field 0 Text Field 0 Text Field 0 Text Field 0 Text Field 0 Text Field 0 Text Field 0 Text Field 0 Text Field 0 Text Field 0 Text Field 0 Text Field 0 Text Field 0 Text Field 0 Text Field 0 Text Field 0 Text Field 0 Text Field 0 Public Issue 2 0 February 1 2012 Conforming Meter Framework Appe
26. nce MTRs resulting from momentary power outages caused by distribution system circuit breaker autoreclosures This can be achieved by defining a time period of between 3 and 15 seconds before a valid Power Outage Status will be assigned by the meter to a load profile interval IESO staff will review meter programming selections during metering installation audits The IESO will not allow MSPs to program any conforming meter in a manner that unreasonably masks power outage events that exceed 15 seconds This ensures that any interval for which voltage supply to the meter is interrupted for more than 5 of its 5 minute duration is properly flagged with a power outage status in MV 90 Where the IESO becomes aware that an MSP has programmed a meter to unreasonably mask short term power outage events the IESO will require the MSP to replace the meter with one that has been properly programmed 8 Public Issue 2 0 February 1 2012 Conforming Meter Framework 3 Meter Specific Issues The Itron SENTINEL has a single Load Profile section that can each be programmed to record up to 8 quantities Due to the fact that the Itron SENTINEL meter is approved for use in the IESO Markets as an ALTERNATE meter only the IESO will only support reading information from channels 1 to 4 If channels 5 to 8 are configured to measure other quantities the IESO considers these channels aa UNCONNECTED and the MSP must assign UOM 42 to each of these channels in
27. ndix C Sample Itron PC PRO Advanced Program Listing for the Itron SENTINEL Meter Item 27 Format Text Field Item 28 ID 0 Item 28 Format Text Field Item 29 ID 0 Item 29 Format Text Field Item 30 ID 0 Item 30 Format Text Field Item 31 ID 0 Item 31 Format Text Field Item 32 ID 0 Item 32 Format Text Field Test Display Format Item 1 ID 11 Item 1 Format xxxxxx Kilo Annunciator Leading Zero Item 2 ID 12 Item 2 Format xxxxxx Kilo Annunciator Leading Zero Item 3 ID 31 Item 3 Format xxxxxx Kilo Annunciator Leading Zero Item 4 ID 32 Item 4 Format xxxxxx Kilo Annunciator Leading Zero Item 5 ID 15 Item 5 Format xxxx xx Units Annunciator No Leading Zero Item 6 ID 16 Item 6 Format xxxx xx Units Annunciator No Leading Zero Item 7 ID 35 Item 7 Format xxxx xx Units Annunciator No Leading Zero Item 8 ID 36 Item 8 Format xxxx xx Units Annunciator No Leading Zero Item 9 ID 0 Item 9 Format Text Field Item 10 ID 0 Item 10 Format Text Field Item 11 ID 0 Item 11 Format Text Field Item 12 ID 0 Item 12 Format Text Field Item 13 ID 0 Item 13 Format Text Field Item 14 ID 0 Item 14 Format Text Field Item 15 ID 0 Item 15 Format Text Field Item 16 ID 0 Item 16 Format Text Field Demand Thresholds Demand Threshold 1 Quantity Unassigned Threshold 1 000 Demand Threshold 2 Issue 2 0 February 1 2012 Public C 7 Appendix C Sample Itron PC PRO Advanced Program Listing for the It
28. nput when the Meter Type it standalone and is grayed oul fes other meter types UOM is the Unit of Measure code assigned to define the channel data of the recorder This code must be the same as in the Meter Channel Master record for each channel The UOM code is important because it is the link to the proper heading as well as the proper calculation to convert pulse data to engineering units z End of Section Issue 2 0 February 1 2012 Public 3 3 Meter Specific Issues IESO STD 0066 3 Meter Specific Issues 3 1 Meter Manufacturer s Programming Software The Itron SENTINEL meter is programmed using the Itron PC PRO Advanced software application program This software was formerly known as PC Pro 98 Advanced oe Program Editor Untitled Communications Options Hep PC PRO Advanced Programming A portiag and Mba surement Analysis Additional information on this software and the Itron SENTINEL meter is available at www itron com 3 2 Meter Programming Requirements Conforming Meters used in the IESO Markets must be approved and must be programmed to comply with the requirements of section 5 of the current issue of the Wholesale Revenue Metering Standard Hardware The Meter ID field in the PC PRO Advanced meter programming software is mapped to the Device ID field in MV 90 As detailed in section 5 8 of the Wholesale Revenue Meter Standard Hardware the Meter ID
29. o JEN Pulse Multiplier 0 42 Maximum Interval Demand Service Type we gt Power Flow Direction Received Minimum Interval Demand aaa Register Type E z Pulse Offset gt Zero Interval Tolerance Taz Number of Dials ja Unit of Measurement Code 03 Load Factor Tolerance eg Encoder Type TS Redundant Meter Channel Power Factor Tolerance KYA Set Number 2 ana Bi Change Between Intervals Omit On Upload 7 General Help Use this form to set up and edit information for each channel in the meter The middle column of fields only accepts input when the Meter Type is standalone and is grayed out for other meter types End of Section Issue 2 0 February 1 2012 Public D 9 Conforming Meter Framework References References Document Name Document ID IESO Wholesale Revenue Metering Standard Hardware MDP STD 0004 IESO Market Manual 5 Settlements MDP_PRO_0032 Part 5 2 Meter Data Processing IESO Market Rules Chapter 9 MDP_RUL_0002_09A Settlements and Billing Appendices IESO Market Rules Chapter 6 MDP_RUL_0002_06 Wholesale Metering IESO Conforming Meter Framework IESO STD 0064 Itron QUANTUM Q1000 Itron SENTINEL Meter Technical Reference Guide Effective October 2004 Itron PC PRO Advanced SENTINEL Device User s Manual also known as the SENTINEL Online Manual Edison Electric Institute Handbook for Electricity Metering 10 Edition End of
30. oad Profile Configuration Pire Wanghi bel Ooms 0Q 2 fo 025 0025 Un ars gned Uneragred Uneragred Unat sged NOTE Selecting a Net Quantity w l maui in the koce of one b of pecwon for af of you Load Paule values Ok Cancel Hel Option Board Option Board SENTINEL Modem This is the normal selection for an internal modem Configuration Configuration Enabled The meter can be ordered with an optional RS 232 RS 485 board 2 versions This optional board can provide either one or two RS 232 or RS 485 interfaces that can be connected to an external modem For additional details please refer to Chapter 5 Communications in the Itron SENTINEL Meter Technical Reference Guide Event Configuration No specific IESO programming requirements at this time Service Clock Line Sync Configuration Synchronization Service Type Auto Service Sense No specific IESO programming requirements at this time Issue 2 0 February 1 2012 Public 3 Meter Specific Issues IESO STD 0066 3 2 1 Power Outage Length Definition The Itron SENTINEL meter allows the user to define the minimum time period to allow the interruption of voltage to the meter s internal power supply before the meter assigns a Power Outage Status flag to a load profile interval This is defined in PC PRO Advanced using the Outage Length field on the Load Profile Configuration tab MSPs are encouraged to use this functionality to reduce the number of nuisa
31. odes within the PC PRO Advanced meter programming software Each level of security code must be unique and may use an alphanumeric string of up to 20 twenty characters in length The definition and capability of each level of these security codes is provided in the following table Table 3 Itron SENTINEL Security Code Definitions Security Code Description Comments Primary Provides read write access to the meter including all programming options The only function not available to this permission level is the ability to download new firmware to the meter Limited Reconfigure Provides read and limited write access including the ability to reset demand change the time in the device and reconfigure the device Does not allow clearing of billing data change of display modes or change of security codes Secondary The Secondary security code provides read only access to the meter plus the ability to Reset Demand Registers reconfigure communications change the meter s Display Mode to Alternate and set the device clock The IESO will use the Secondary security code to obtain read access to the meter with time reset capability When SENTINEL meter s Event Log is full MV 90 will return Error 22 and time synchronization will not be performed The meter s Event Log will have to be reset using PCPRO Advanced software Tertiary The Tertiary security code provides read only access to
32. or No Logon Successful No Loss of Phase Yes Loss of Phase Restored Yes Low Battery Yes Meter Reprogrammed No Option Board No Power Outage Yes Power Restored Yes Register Self Read Yes Reverse Power Flow Yes Reverse Power Flow Restored Yes Season Change No Security Fail Yes Security Pass No SiteScan Error No Test Mode Entered No Test Mode Exited No Time Changed Yes TOU Schedule Error No Issue 2 0 February 1 2012 Public C 11 Appendix C Sample Itron PC PRO Advanced Program Listing for the Itron SENTINEL Meter C 12 Delay until Service Sense Auto Detect 6S in 9S User Data User Data 1 User Data 2 User Data 3 15 Seconds No End of Section Public IESO_STD_0066 Issue 2 0 February 1 2012 Conforming Meter Framework Appendix D Sample MIRT File Screen Images for the Itron SENTINAL Meter Appendix D Sample MIRT File Screen Images for the Itron SENTINEL Meter The following screen images were developed using the MIRT version 1 05 a software MSPs and MMPs should use the following link to ensure they check for updated versions of the MIRT software prior to creating a new MIRT file submission www ieso ca imoweb metering mirt asp MSPs normally submit completed MIRT files to the IESO via e mail to MV90MasterFiles ieso ca Where the MSP has programmed the meter with any non standard value i e Ke register rollover etc the body of the e mail message to which the MIRT file is attached s
33. red into the Number of Dials field to be an integer between 3 and 9 Appendix B provides a summary of the calculations that were prepared by IESO staff to determine a standard minimum pulse weight K value for Wh pulse and VARh pulse of 0 025 unit hours per pulse for the Itron SENTINEL meter MSPs should revisit these calculations for their specific circumstances prior to programming a new Itron SENTINEL meter if they plan to install a meter on a metering installation that uses an input secondary voltage other than 120 Volts or if they plan to operate the meter with a maximum input secondary current in excess of 7 5 Amps J vm e Issue 2 0 February 1 2012 Public 5 3 Meter Specific Issues IESO STD 0066 The following highlights must be addressed when a PC PRO Advanced program is developed for use with an Itron SENTINEL meter for use in the IESO markets Table 1 IESO Items of Interest within PC PRO Advanced Programs for the Itron SENTINEL Meter Program Section Item IESO Setting Comments Description Measurement Level 2 and Measurement level 2 is the minimum level required Level Bi Directional plus Bi directional measurement capabilities required for IESO conforming alternate meter Device Operation Use DST Dates No All meters in the IESO markets use EST only Enable Bi Yes Bi directional measurement capability is required by Directional the IESO M
34. ron SENTINEL Meter Quantity Threshold Demand Threshold 3 Quantity Threshold Demand Threshold 4 Quantity Threshold Normal Mode Register Operation Demand Interval Length Number of Subintervals Cold Load Pickup Time Outage Length before Cold Load Pickup Demand Reset Lockout Time Test Mode Register Operation Test Interval Length Number of Subintervals LED Normal Mode Kh Normal Kh LED Alternate Mode Quantity LED Alternate Mode Kh Normal Kh 2 LED Test Alt Mode Quantity LED Test Alt Mode Test Kh Switch Operation Mode Timeout Disable Demand Reset Switch Disable Test Mode Switch O kan ji D ko D a IESO STD 0066 Unassigned 1 000 Unassigned 1 000 Unassigned 1 000 15 Minutes ev 5 Minutes 900 Seconds 1 Minutes 3 Minutes eo C nassigned Public Issue 2 0 February 1 2012 Conforming Meter Framework Appendix C Sample Itron PC PRO Advanced Program Listing for the Itron SENTINEL Meter Pulse Weight Channel 6 Pulse Weight Channel 7 Pulse Weight Channel 8 Pulse Weight Self Read Configuration Self Read Schedule Scheduled Day Scheduled Hour Scheduled Minute Reset Demand after Read Billing Schedule Configuratio Billing Schedule SiteScan Configuration 1 Cross Phase Polarity Energy Flow Check Current Lead Lag Tolerance 2 Phase Voltage Deviation Check Percent Tolerance for Phase Voltage Deviation 3 Inactive Phase Current Check 4 Pha
35. rt Holiday Window 1 Stop Holiday Window 2 Start Holiday Window 2 Stop Phone Home Configuration Blind Dialing Enabled Blind Dialing Wait Time Allow Call Outside Call Window Time to Wait for Answer Number of Attempts Limit Retries Dial Type Phone Number 1 Phone Number 1 Baud Rate Phone Number 2 Phone Number 2 Baud Rate Phone Number 3 Phone Number 3 Baud Rate Phone Number 4 Pulse on Event Demand EOI 10 msec None selected None selected No No No 10 4 2400 00 00 23 59 00 00 23 59 00 00 23 59 00 00 23 59 00 00 23 59 00 00 23 59 00 00 23 59 00 00 23 59 No 5 No 60 16 No Tone Dialing None 2400 None 2400 None 2400 None Public IESO_STD_0066 Issue 2 0 February 1 2012 Conforming Meter Framework Appendix C Sample Itron PC PRO Advanced Program Listing for the Itron SENTINEL Meter Phone Number 4 Baud Rate 2400 Initial Phone Home Type No Initial Call Scheduled Phone Home Event Configuration Number of Events 0 Event Configuration Clear Billing Data Yes Configuration Error Yes Demand Reset Yes Demand Threshold Exceeded Yes Demand Threshold Restored Yes Diagnostic 1 Off Yes Diagnostic 1 On Yes Diagnostic 2 Off Yes Diagnostic 2 On Yes Diagnostic 3 Off No Diagnostic 3 On No Diagnostic 4 Off Yes Diagnostic 4 On Yes Diagnostic 5 Off Yes Diagnostic 5 On Yes DST Time Change No Event Log Cleared No Full Scale Overflow Yes Input High No Input Low No Load Profile Err
36. s for the Itron SENTINEL Meter IESO STD 0066 Metering Installation Registration Tool File Help Customer Information iA Recorder Remote Interrogation Meter Channel Information Recorder ID 1000078911 Location SPECIFIC TS M27 PME Battery Install Date is a Wr Recorder Call Mode Jan DST Option On Recorder MM DD Recorder Memory Size in KB 96 Allow Auto Time Set y Date lnitialized TT 1f fc YY MM DD hhmm Check Redundant Meter ID Check Meter Correlation Factor TIM Number 3 Device Type Name Intervals per Hour 12 v Meter Type Redundant Meter Device Type Schlumberger SENTINEL x SENTINEL Device Serial Number ABH12346 Device ID 5ABH12346 Auto Plug Option General Help Use this form to enter basic information about the meter including the meter type brand and serial number If the Meter Type is Main you must enter the Meter Point ID for the check or alternate meter in the Check Redundant Meter ID field The IESO requires the SENTINEL s meter inspection number also referred to as the meter badge number in the Device Serial Number field The Device ID must contain an alphanumeric string that begins with the letter S is at least 7 and not more than 15 characters in length and is unique in the IESO MV 90 database Public Issue 2 0 February 1 2012 Conforming Meter Framework Appendix D Sample MIRT File Screen
37. se Angle Displacement Check Tolerance for Phase Angle Displacement Minimum Current Threshold 5 Current Waveform Distortion Check I O Configuration O Board Type Disable Output in Test Mode Output 1 Output Type Output Quantity Pulse Weight Pulse Width Output 2 Output Type Output Quantity Pulse Weight Pulse Width Output 5 Issue 2 0 February 1 2012 1 000 Unassigned 1 000 Unassigned 1 000 Unassigned 1 000 Self Read on Nth Day of Month 1 0 1 No n None Scheduled Scroll 90 0 Degrees Scroll 1096 Disable Ignore 65 0 Degrees 0 5 Scroll Solid State Contacts with 2 KYZ 1 LC and 2 Pulse State Inputs No Toggle on Energy Whd 0 050 0 msec Toggle on Energy varh d 0 050 0 msec Public C 9 Appendix C Sample Itron PC PRO Advanced Program Listing for the Itron SENTINEL Meter Output Type Output Quantity Pulse Width Input 1 Desired Action Input 2 Desired Action Option Board Configuration Modem Configuration Off Hook Detect Enabled Phone Line Sharing Enabled Answer Outside Call Window Outside Call Window Answer Delay Inside Call Window Answer Delay Answer Baud Rate Weekday Window 1 Start Weekday Window 1 Stop Weekday Window 2 Start Weekday Window 2 Stop Saturday Window 1 Start Saturday Window 1 Stop Saturday Window 2 Start Saturday Window 2 Stop Sunday Window 1 Start Sunday Window 1 Stop Sunday Window 2 Start Sunday Window 2 Stop Holiday Window 1 Sta
38. ta in units of kWh As a result MV 90 was designed to use UOM code 01 in units of kWh When the SENTINEL meter was developed they chose to record accumulated energy in base units such as Watt hours and VAR hours to take advantage of 32 bit software storage capability This created a scaling challenge for MV 90 as it normally receives encoded energy register readings in the same units of measure kWh kVARh as the pulse weights used for measuring load profile interval energy consumption The Itron TIM development team learned from the experience they gathered in working with the Itron QUANTUM Q1000 meter In early 2002 when Itron developed the initial TIM for the Itron SENTINEL meter they designed the TIM module to properly interrogate the SENTINEL meter s encoded energy registers and by default store the energy register readings in kilo units within MV 90 This enabled most MV 90 users to treat the MV 90 Master File set up for the Itron SENTINEL meter in a traditional manner that is used for most multi function electronic meters with load profile capability Specifically in the MV 90 Master File for channel data the pulse weights used for UOM codes 01 kWh and 03 kV ARh are entered in kilo units per pulse and the meter multiplier is entered as the product of PT ratio CT ratio This enables the normal MV 90 validation tolerance of 100 of the meter multiplier to work properly for reliable and consistent automatic validation of to
39. tal load profile pulse accumulation vs difference in encoded register readings for this meter Similar to the Q1000 meter the Itron SENTINEL meter is a 16 bit meter that is capable of storing pulse counts of up to 65 535 2 7 pulses per interval However MV 90 uses a 15 bit algorithm to store interval data in P files and only supports reading interval data to a maximum of 32 766 pulses per interval While the Itron SENTINEL can store up to 65 535 pulses per interval it is not possible to take full advantage of this functionality when using 5 minute intervals The range of load profile channel pulse weights K for the Itron SENTINEL meter available in the PC PRO Advanced software is between 0 025 and 800 000 unit hours per pulse in increments of 0 025 The calculations provided in Appendix B illustrate that when the SENTINEL is programmed to use the smallest available pulse weight of 0 025 unit hours per pulse it is still highly unlikely even with extreme values for secondary meter inputs that MV 90 s interval pulse limit of 32 766 will be exceeded in a 5 minute interval For this reason the IESO has adopted 0 025 unit hours per pulse as its standard pulse weight for the Itron SENTINEL meter for UOM codes 01 and 03 Alternate Meters Issue 2 0 February 1 2012 Public 11 3 Meter Specific Issues 3 5 IESO STD 0066 Interval Data and Channel Data Status Codes The Itron SENTINEL meter provides two types of interval dat
40. the meter No operation that writes to the meter is allowed Firmware Download Access This security code provides unrestricted access to the meter that includes the ability to download new firmware to the meter For meters that have been initialized using the Canadian version of PC PRO Advanced the firmware can only be upgraded if the meter s seal is first cut to allow a 3 button reset to be performed prior to attempting to upgrade the meter s firmware While PC PRO Advanced will allow security codes of up to 20 characters in length to be programmed into the Itron SENTINEL meter MV 90 manages this string by taking the entire 20 character string in the Reader Password field of the Recorder Master File For additional details refer to the sample MIRT file screen images shown in Appendix D Public Issue 2 0 February 1 2012 Conforming Meter Framework 3 Meter Specific Issues 3 4 MV 90 Operations Similar to the Itron QUANTUM Q1000 meter there are two key characteristics of the Itron SENTINEL meter that have challenged MV 90 and its users since the meter s introduction These are the SENTINEL s method of storing its internal encoded energy registers in base units and its ability to store pulse counts with 16 bit resolution Fortunately these two issues were addressed early in the SENTINEL meter s life Traditional energy meters have presented accumulated energy consumption da
41. time reset capability The Portable Reader Password field is used to hold the specific address of the meter if a multi drop RS 232 or RS 485 interface bus is used to communicate with multiple meters at the same site Valid addresses are numbers between 1 and 254 The IESO recommends that the MSP only populate this field after they have proven reliable communication with the meter using their own MV 90 system D 4 Public Issue 2 0 February 1 2012 Conforming Meter Framework Appendix D Sample MIRT File Screen Images for the Itron SENTINAL Meter Metering Installation Registration Tool File Help Customer Information Recorder Information Recorder Remote Interrogation Meter Channel Information Recorder ID Location Device Type Local Phone No 9051234567 1234 Daisy Chain No Master Slave v Remote Phone No 33 ID of Master in Chain Baud Rate 2400 ID of Next Slave in Chain Phone Password 1 Answer Window Time to Phone Password 2 Answer Window Days Portable Reader Password CD345678901234567890 Unit Address General Help Use this form to enter phone number password and daisy chain information for the meter Include the area code in the local phone number for example 4162123904 Note When a MIRT file is submitted the first 10 characters in the Local Phone No field must consist of the exact 10 digit telephone number 3 digit area code plus 7 digit local telephone number witho
42. ty Figure 1 Typical Socket Meter for the Itron SENTINEL Meter Issue 2 0 February 1 2012 Public 2 TESO MV 90 System Configuration IESO_STD_0066 2 IESO MV 90 System Configuration 2 1 MV 90 UOM Codes The IESO s MV 90 system has been configured to accept only UOM codes 01 kWh 03 kVARh 07 V h 10 Ph and 42 UNUSED for all incoming MIRT files for new and upgraded meter registrations Once the legacy meters have been deregistered these will be the only UOM codes used in the IESO s MV 90 system Conforming meters that have been programmed to record information on any channels beyond 10 for Main meters or beyond 4 for Alternate meters must be submitted with a Metering Installation Registration Tool MIRT file that has been configured with UOM code 42 UNUSED for all additional channels that are not used by the IESO 2 Public Issue 2 0 February 1 2012 Conforming Meter Framework 2 IESO MV 90 System Configuration All pulse weight values that are entered into the Pulse Multiplier field of every channel record in a MIRT file must be in units that are dimensionally consistent with the IESO s MV 90 system s UOM code definitions as shown on the previous page For example all pulse weight values that are entered for UOM code 01 MUST be in units of kWh pulse Similarly UOM code 03 pulse weights must be in units of kVARh pulse UOM code 07 must be in units of V7h pulse and UOM co
43. used by the SEINTEL meter can be viewed by using the PC PRO Advanced software to view the meter s load profile data in tabular format For additional information please refer to the Itron PC PRO Advanced SENTINEL Device User s Manual 12 Public Issue 2 0 February 1 2012 Conforming Meter Framework 3 Meter Specific Issues 3 6 Meter Event Codes The Itron SENTINEL meter contains a circular event log file that will track the most recent 188 to 412 events The number of events recorded before the log wraps around is dependent on the size of the information recorded with the specific type of event The event log records and event code along with the date and time at which specific meter events and meter diagnostic errors occurred For additional details on this topic please refer to Chapter 3 of the Itron SENTINEL Meter Technical Reference Guide The IESO s MV 90 system has been configured to utilize the MV 90 Event Reference Database functionality for enhancing its meter data validation procedures The IESO is currently utilizing a subset of these event codes within its validation procedures to support the identification of abnormal meter events such as battery failure etc We expect this capability will be expanded in the future as the IESO MSPs and MMPs gather more experience working with MV 90 and the event log functionality of both the Itron SENTINEL meter and other conforming meters Issue 2 0 February 1 20
44. ut any other characters such as commas hyphens etc The Local Phone No field above shows the complete 10 digit phone number for the meter including the leading area code 9051234567 the dialing delay characters a comma is typically a 0 5 to 2 second delay and the tilde symbol is equivalent to 5 commas the internal telephone extension number 1234 and the transfer character some automated telephone attendants require IESO staff will add any leading characters typically 9 if it is a local call for the IESO or 91 if it is a long distance call to the telephone number in this field when they initially attempt to call the meter using the IESO s MV 90 system If the meter has a complicated dial string that exceeds 17 digits in the MIRT file then the MSP must enter a symbol at the 18 character position in the Local Phone No field and then enter the balance of the dial string to a maximum of 20 additional digits in the Remote Phone No field such as additional dialing delay codes and the address of the port that the meter is connected to on the telephone line sharing switch 33 in this example The Local Phone No field will accept up to a 20 character dial string The 17 limit reserves space for two additional characters for the IESO staff to add in a leading 91 and one additional character for the symbol to instruct MV 90 to look for the balance of the dial string in the Remote Phone
45. ver The Normal Seal Life of an Itron SENTINEL Meter Seal Life Years 10 Number of Days 3 650 Number of Hours 87 600 5 Min Intervals 1 051 200 Meter Inputs assume worst case continuous operation at these levels Power Elements Volts Amps Factor 3 7 5 Maximum MIRT File Wh and VARh Registers Number of Number of Dials If offered the Required Digits on Value to be used by Energy 262 50 Wh PC PRO Advanced Meter s Internal MV 90 TIM 30 for per Interval Register Rollover nga Energy Register Channels 1 to 4 Selection would be kWh KVARh igits Energy over 275 940 000 Wh 1 000 000 000 10 Year Period By default the IESO will force MV 90 to use the largest rollover setting possible in MV 90 for the Itron SENTINEL meter 9 Dials Itron Canada Technical Support confirmed on January 18 2005 that the Itron SENTINEL meter s internal encoded energy registers do not rollover until they accumulate 2 or 1 8 x 10 Wh Issue 2 0 February 1 2012 Public A 1 Appendix A Calculation of the Practical MV 90 Energy Register Rollover Value for the Itron SENTINEL Meter IESO STD 0066 This page intentionally left blank End of Section A 2 Public Issue 2 0 February 1 2012 Conforming Meter Framework Appendix B Minimum Pulse Weight Calculations for Load Profile Channels of the Itron SENTINEL Meter Appendix B Minimum Pulse Weight Calculations for Load Profile Channels of the Itron SENTINEL Met