Home

C-Splash 2 User Guide

image

Contents

1. Earth Ground S PDS 60 DMX Ethernet WARNING Ensure that power supply is off before wiring or con necting fixtures to PDS 150e Failure to do so can result in serious injuries or death CAUTION Connect the C Splash 2 ground wire to the power data supply chassis Failure to connect the ground wire can result in property damage and void the warranty AIMING THE FIXTURE Aiming C Splash 2 is simple with the aim and lock feature 1 After installing and energizing the light horizontally pivot the fix ture in the yoke to the desired position 2 Using a 3 16 hex key tighten the pivot bolts to hold the fixture in position See Fig 7 3 Using a 1 8 hex key tighten the locking set screws to lock the fixture in place See Fig 7 Fig 7 3 16 Hex Key Tighten fixture after swiveling into position 5 16 Hex Key Loosen to rotate fixture on the base Tighten after a a 2 Hex Key Lock fixture into position Base Bolt ROTATING THE FIXTURE 1 If after installation it becomes necessary to rotate the fixture use a 5 16 hex key to loosen the base bolt See Figure 7 2 Vertically rotate the yoke then tighten the base bolt NOTE The fixture allows 360 vertical and horizontal rotation CAUTION Do not over tighten set screws CAUTION Do not allow cable to become pinched in housing IMPORTANT INFORMATION Strobe Wa
2. CAUTION C Splash 2 has no serviceable parts Do not attempt to open the fixture Doing so will result in property damage and void the warranty CAUTION Do not use sharp tools near or on the fixture lens Doing so will result in property damage and void the warranty CAUTION Do not hot swap Ensure the power supply is off before connecting or disconnecting fixtures Hot swapping will result in property damage and void the warranty CAUTION Do not remove or loosen sealing bolts Doing so will destroy the water tight seal result in property damage and void the warranty CAUTION Do not remove or loosen cable compression fitting Doing so will destroy the water tight seal result in property damage and void the warranty NOTE The instructions and precautions set forth in this user guide are not necessarily all inclusive all conceivable or relevant to all applications as Color Kinetics cannot anticipate all conceivable or unique situations Owner User Responsibilities It is the responsibility of the contractor installer purchaser owner and user to install maintain and operate C Splash 2 in such a man ner as to comply with all state and local laws ordinances regula tions and the American Standard Institution Safety Code PLANNING THE INSTALLATION The nature of the C Splash 2 installation requires planning to ensure a timely successful installation with minimal complications and down time Planning Suggestio
3. 823mm CSA 4 conductor stranded copper Maximum single run distance from PDS 60 to fixture 150 ft 46 m Color Kinetics Controller Maximum Two C Splash 2 fixtures per PDS 60 power data supply DMX IN CAT5 RJ45 L 2 100 240VAC Power Data Cable 7 18AWG 823mm CSA PDS 60 DMX Ethernet 3 conductor stranded copper C Splash 2 with PDS 60 24V DMX Control bE Roon PDS 60 DMX Ethernet Maximum cable run from DMX OUT _ 60W Power Data Supply to Lights 150 feet 46 m DMX IN DMX CAT5 RJ45 Controller SOS S 24V for Accessory power data cable included with fixture oy a ei Controller as required he Tl er ENE C Splash 2 with PDS 60 24V Ethernet Control H Ethernet IN 8 B D Earth Ground Ethernet V P Switch Light System Engine PDS 60 DMX Ethernet Power Data Cable PC 18AWG 823mm 2 CSA 3 conductor stranded copper Maximum cable run from 60W Power Data Supply PC used for show to Lights 150 feet 46 m authoring and show control 60 foot 18 3 m power data cable included with fixture Ethernet IN TOOT
4. chassis See Fig 4 GROUND Fig 4 A RING SS TERMINAL To C Splash 2 100 240VAC RING TERMINAL l For PDS 60 24V Using wire nuts connect the green ground wire from each C Splash 2 to the earth ground on PDS 60 Fig 5 ToC Splash 2 See Fig 5 Figure 6 shows C Splash 2 fixtures connected to PDS 150e and PDS 60 See Figure 4 for details on proper grounding for PDS 150e Connecting Power Follow the instructions in PDS 150e or PDS 60 Installation Guide to connect power from a 100 to 240 VAC power source Fig 6 Maximum single run distance from PDS 150e 150 ft 46 m 60 foot 18 3 m power data cable 2 e included with fixture o J mam ammm toca to 38 CAT 5 RJ45 Cl qe H _ Data Cable gs PDS 150e Color Kinetiese aeren aca ae Power Data supply Controller T all bs H c AET Ea E ze One per terminal C Splash 2 with PDS 150e Power Data Cable 18AWG 823mm CSA 4 conductor stranded copper From PDS 1 50e Power Data Supply maximum accumulated length of cable run for all fixtures must not exceed 400 feet 122 m 100 240VAC Maximum Six C Splash 2 fixtures per PDS 150e power data supply C Splash 2 with PDS 60 Preprogrammed 60 foot 18 3 m power data cable included with fixture Power Data Cable 18AWG
5. control millions of colors with an increasing range of lighting effects and capabilities This User Guide contains important information about proper installation and safe operation of your new C Splash 2 light fixture C Splash 2 is a completely submersible fixture primarily designed for use in fresh or salt water up to fifteen feet deep but can be used in partially submerged or dry locations See Figure 1 Fig 1 BACK VIEW SIDE VIEW EC POWER DATA Lf CABLE C Splash 2 Light Fixture Detail Included in This Box e C Splash 2 with 60 foot cable e User Guide Additional Items Needed e Mounting base hardware 3 each 3 8 16 Silicon Bronze cap screw 3 8 Silicone Bronze round flat washer plus appropriate anchoring hardware e 5 16 3 16 and 1 8 hex key e 18 AWG minimum ground wire e 24VDC power supply PDS 150e Item 109 000008 01 or PDS 60 24V Item 109 000017 00 03 e Controller Color Kinetics DMX Controller or DMX compatible e Color Kinetics Zapi ltem 103 000005 00 US 103 000005 01 EU or Serial Addressing Software SAS Scope of This User Guide The goal of this user guide is to explain the steps necessary to install C Splash 2 and assure peak performance Its intended use is for refer ence only by persons who are fully qualified This document should never be considered a substitute for any provisions of a regulation or state and or local c
6. for SSL lifetime LED lumen depreciation is affected by numerous environmental conditions such as ambient temperature humidity and ventilation Lumen depreciation is also affected by means of control thermal management current levels and a host of other electrical design considerations Color Kinetics systems are expertly engineered to optimize LED life when used under normal operating conditions Lumen depreciation information is based on LED manufacturers source life data as well as other third party testing Low temperatures and controlled effects have a beneficial effect on lumen depreciation Overall system lifetime could vary substantially based on usage and the environment in which the system is installed Temperature and effects will affect lifetime Color Kinetics rates product lifetime using lumen depreciation to 50 of original light output When the fixture is running at room temperature using a color wash effect the range of lifetime is in the range of 80 000 100 000 hours This is LED manufacturers test data High output is defined as any LED device that is 1 2 watt or above For more detailed information on source life please see www colorkinetics com lifetime WARRANTY This product is sold pursuant to CK s Standard Terms and Conditions the T amp Cs which may be found at http colorkinetics com howtobuy buy terms and which contain important provisions including among others Limited Warranty exclusions and
7. limita tions on CK s liability for damages and restrictions on the remedies that are available fo you
8. to remember e Install C Splash 2 fully submerged partially submerged or in dry location e Install C Splash 2 in fresh or salt water CAUTION Install C Splash 2 fixture before wiring it to the power data supply to minimize risk of electric shock e The maximum submersion depth is 15 Fig 2 feet 5 meters e Install C Splash 2 horizontally verti cally or inverted Mounting C Splash 2 1 Using the provided C Splash 2 template or the C Splash 2 base mark the installation locations 2 Attach fixture to mounting surface with three 3 8 16 silicon bronze cap screws and washers using the method best suited for the mounting surface See Fig 2 Making Electrical Connections After installing the power data sup ply and C Splash 2 fixtures you are ready to make the electrical connec tions 3 8 FLAT WASHER SILICONE BRONZE 1 Pull the cable from the fixtures to the power data supply 2 Pull the cable through knock outs in the side of the power data supply 3 Wire the red white and black wires of each fixture to a provid ed connector then snap connectors into the connector terminals located in the power data supply Ensure that the wire colors cor respond to the 3 pin terminal block notations See Fig 3 A For PDS 150e Using wire nuts connect the green ground wire from each C Splash 2 to the earth ground on PDS 150e Secure the ring terminal to the
9. C SPLASH 2 USER GUIDE COLOR KINETICS INCORPORATED 10 MILK STREET SUITE 1100 BOSTON MA 02108 USA TEL 888 FULL RGB TEL 617 423 9999 FAx 617 423 9998 INFO COLORKINETICS COM CHROMACORE BY COLOR KINETICS OPTIBIN BY COLOR KINETICS ITEM 116 00001 1 00 Frosted Lens ITEM 116 000011 01 Clear Lens C This product is protected by one or more of the following U S Patents and their foreign counterparts 6 016 038 6 150 774 6 340 868 6 774 584 6 781 329 6 936 978 6 969 954 and 6 975 079 Other patents WWW COLORKINETICS COM pending 2002 2007 Color Kinetics Incorporated All rights reserved Chromacore c US Chromasic CK the CK logo Color Kinetics the Color Kinetics logo Color Kinetics The Leader in Intelligent Light ColorBlast ColorBlaze ColorBurst LISTED ColorCast ColorPlay ColorScape DIMand Direct Light EssentialWhite eW 88UF iColor iColor Cove IntelliWhite iW iPlayer Light Without Limits Optibin Powercore QuickPlay Sauce the Sauce logo and Smartjuice are either reg istered trademarks or trademarks of Color Kinetics Incorporated in the United States and or other countries PUB 000142 00 Rev 02 Specifications subject to change without notice Refer to www colorkinetics com for the most recent version INTRODUCTION Congratulations on your purchase Welcome to a more colorful world brought to you by Color Kinetics core technologies and products that generate and
10. ns When planning the C Splash 2 installation Color Kinetics suggests doing the following e Consult an Electrical Inspector to approve all wiring plans e Refer to local and state codes for installation compliance e Create a Mapping Grid Use this grid to record serial numbers for easy reference and addressing e Create a Layout Plan drawing per Lighting Designer or Architect e Employ Color Kinetics Application Engineering Services e Get detailed wiring diagrams and additional support from http support colorkinetics com Installation Considerations When creating your installation plan consider the following e Location of the power data supply in relationship to lights e The maximum accumulated cable length for all C Splash 2 fixtures connected to a single PDS 150e is 400 feet The maximum single cable run between PDS 150e and C Splash 2 is 150 feet e The maximum cable length for a C Splash 2 fixture connected to a PDS 60 is 150 feet Therefore PDS 60 must be located within 150 feet of the furthermost supported fixture e Location of fixture C Splash 2 can be installed fully submerged partially submerged or in dry locations horizontal vertical or inverted e Record the serial numbers and identify lights as you unpack the fixtures e Install and wire power data supply before installing C Splash 2 fixtures Refer to the PDS 150e or PDS 60 24V Installation Guides INSTALLING C SPLASH 2 Steps to a Successful I
11. nstallation 1 Record serial numbers and identify fixtures as you unpack them 2 Address the fixtures 3 Install the power data supplies 4 Install C Splash 2 fixtures 5 Make electrical connections Recording Serial Numbers 1 As you unpack the fixtures record the serial numbers Each C Splash 2 has a unique serial number programmed at the time of manufacture 2 Write the serial numbers onto a Mapping Grid or use a bar code scanner along with Color Kinetics Serial Addressing Software SAS to record each serial number Color Kinetics SAS and instructions are located at www colorkinetics com support downloads 3 Using the Layout Plan assign the fixture to a layout position in the installation 4 Using a weatherproof label identify the fixtures installation posi tion based on the Layout Plan Place the identifying label in an inconspicuous location noting the order or placement in the instal lation This step not only minimizes installation mistakes but aids in postinstallation light show programming Addressing the Lights IMPORTANT Before you begin the installation consider the scope of your lighting application and installation Your C Splash 2 is set to DMX address one 1 at the factory If your application requires other addresses set the DMX addresses before installing C Splash 2 using one of the following addressing tools ZAPI Use Color Kinetics Zapi to set the DMX address for each fixture or set all fix
12. ode Identification and Warnings of Safety Hazards In accordance with ANSI Z535 4 the following system of identifying the severity of the hazards associated with the products is used DANGER I mminently hazardous situation which if not avoided will result in death or serious injury WARNING Potentially hazardous situation that if not avoided could result in death or serious injury CAUTION Potentially hazardous situation that if not avoided may result in minor or moderate injury or property damage DANGER Ensure that the main power supply is off before installing or wiring C Splash 2 and the power data supply Failure to adhere to these instructions will result in death or serious injury WARNING Do not install in human occupied underwater locations such as pools and spas Doing so could result in death or serious injury WARNING C Splash 2 and the power data supply must be installed by a qualified professional in accordance with NEC and relevant local codes Failure to comply can result in death serious injury or property damage WARNING Do not attempt fo install or use C Splash 2 or the power data supply until you read and understand the installation instruc tions and safety labels Failure to adhere to these instructions could result in serious injury or property damage WARNING Do not use C Splash 2 if the power cables are damaged Doing so can result in death serious injury or property damage
13. oup 888 FULL RGB or 617 423 9999 or www colorkinetics com support C SPLASH 2 SPECIFICATIONS COLOR RANGE SOURCE BEAM ANGLE HOUSING CONNECTORS LISTINGS PROTECTION RATING DATA INTERFACE CONTROL VOLTAGE REQUIREMENT POWER CONSUMPTION POWER SUPPLY TEMPERATURE RANGE SUBMERSION DEPTH LED SOURCE LIFE 16 7 million 24bit additive RGB colors continuously variable intensity output range High intensity power LEDs 10 clear lens 22 ground lens Cast brass Unified power and data cable UL cUL CE IP68 Chromacore technology Color Kinetics full line of controllers or other DMX512 RS485 compatible when using Color Kinetics power data supply 2AVDC 25W Maximum 25 Watts at full intensity full RGB PDS 150e Maximum of 6 fixtures per supply PDS 60 24V Maximum of 2 fixtures per supply 40 F to 122 F 40 C to 50 C operating temperature 4 F to 122 F 20 C to 50 C starting temperature Up to 15 feet 5 meters maximum In traditional lamp sources lifetime is defined as the point at which 50 of the lamps fail This is also termed Mean Time Between Failure MTBF LEDs are semiconductor devices and have a much longer MTBF than conventional sources However MTBF is not the only consideration in determining useful life Color Kinetics uses the concept of useful light output for rating source lifetimes Like traditional sources LED output degrades over time lumen depreciation and this is the metric
14. r supplies 1 With power disconnected connect up fo six C Splash 2 fixtures to the power data supply 2 Attach the Zapi to the DMX IN port on the power data supply 3 Connect power to the power data supply 4 Use Zapi to set the light addresses All C Splash 2 fixtures con nected to the power data supply are addressed simultaneously NOTE If you are using SAS you must input each serial number address separately 5 Disconnect the DMX interface Installing the Power Data Supply Following the Layout Plan install the power data supply according to state and local codes Refer to the PDS 150e or PDS 60 24V Installation Guide for complete instructions WARNING Ensure that power is off before wiring the power data supply Failure to do so can result in serious injuries or death Things to remember e C Splash 2 requires 24VDC provided by PDS 150e or PDS 60 e PDS 150e must be located within 150 feet of the C Splash 2 fix tures and the maximum accumulated cable length for all fixtures is 400 feet Each PDS 150e supports up to six C Splash 2 fixtures e PDS 60 must be located within 150 feet of the C Splash 2 fixtures and each PDS 60 supports up fo two C Splash 2 fixtures e Consult an Electrical Inspector to approve all wiring plans Installing C Splash 2 Fixtures This fixture shall be installed by a qualified professional in accor dance with NEC and relevant local codes for Class 2 power sources Things
15. rnin There is some anecdotal Bees that strobe lighting may induce epileptic symptoms in certain susceptible individuals although no associated product warnings have been issued by United States government according to the Food and Drug Administration If strobe lights are used some international regulatory agencies recommend keeping flicker rates at or below four flashes per second as less of the flicker sensitive population will then be at risk of an attack This flicker rate applies only to the overall output of any group of lights in direct view However when more than one strobe light is used the flashes should be synchronized End users should also consider issuing a warning alerting audience or viewers to the presence of strobe lighting 1 Guide to Health Safety and Welfare at Pop Concerts and Similar Events HMSO Publications UK Temperature Monitoring For protection from extreme temperatures C Splash 2 has been designed with a temperature monitoring feature If operating temperatures rise to an unsafe level a compensation circuit is triggered and the C Splash 2 operation is interrupted causing the lights to turn dull red After 30 minutes the lights will auto cycle and return to full intensity To prevent additional power shut downs determine the cause of the overheating and correct the problem If any problems occur during usage unplug the product immediately and call or email Color Kinetics Technical Support Gr
16. tures to the same DMX address Refer to the Zapi User Guide for step by step addressing instructions SAS SERIAL ADDRESSING SOFTWARE Use a PC with iPlayer 2 or a PC with Smart Jack 3 to address the fixtures Download SAS and instructions from www colorkinetics com support downloads NOTE For applications using multiple daisy chained power supplies you can address alll lights in the chain by attaching Zapi to the first power supply in the series NOTE Multi power supply setups are ideal for pre and postinstalla tion For post installation addressing record all serial numbers and layout positions prior to installation Setting Individual Addresses Using the Serial Number mode of Zapi 1 5 or SAS address each fixture attached to a power supply or a series of connected power supplies individually 1 With power disconnected connect up to six C Splash 2 to the power data supply 2 Attach the DMX interface Zapi iPlayer 2 or Smart Jack 3 to the DMX IN port on the power data supply 3 Connect power to the power data supply 4 Use Zapi or SAS to set the light address of each fixture 5 Disconnect power and then disconnect the addressed C Splash 2 fixture s 6 Repeat steps 1 through 5 for all remaining fixtures 7 After all fixtures are addressed disconnect the DMX interface Setting the Same Address to Multiple Lights Using Zapi 1 5 address all fixtures attached to a power supply or multiple daily chained powe

Download Pdf Manuals