CE EMC TEST REPORT (EN 50155 & EN 50121-3-2)
Contents
1. CE EMC TEST REPORT EN 50155 amp EN 50121 3 2 REPORT NO CE141111C02 1 TEST MODEL SPC 2845 SERIES MODEL Vecow SPC Series SPC 2145 SPC 2845 WA SPC 2845X SPC 2845R SPC 2845D SPC XXXXXXXXXX X can be 0 9 A Z or blank for marketing purpose RECEIVED Nov 11 2014 TESTED Nov 20 2014 Jan 07 2015 ISSUED Jan 09 2015 APPLICANT Vecow Co Ltd ADDRESS 12F No 111 Zhongcheng Rd Tucheng Dist New Taipei City 23674 Taiwan R O C ISSUED BY Bureau Veritas Consumer Products Services H K Ltd Taoyuan Branch LAB ADDRESS No 47 2 14th Ling Chia Pau Vil Lin Kou Dist New Taipei City Taiwan R O C TEST LOCATION No 19 Hwa Ya 2nd Rd Wen Hwa Tsuen Kwei Shan Hsiang Taoyuan Hsien 333 Taiwan R O C This report is for your exclusive use Any copying or replication of this report to or for any other person or entity or use of our name or trademark is permitted only with our prior written permission This report sets forth our findings solely with respect to the test samples identified herein The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us You have 60 days from date of issuance of this r
2. Report No CE141111C02 1 24 of 56 Report Format Version 5 0 4 4 2 7 TEST RESULTS Detector Function amp Frequency Range 30MHz 1GHz Bandwidth Quasi Peak QP 120kHz Input Power 230Vac 50Hz Enron 23 C 6496 RH Conditions Tested by Scott Yang Test Date 2014 11 20 Antenna Polarity amp Test Distance Horizontal at 10 m nic Bion Fea Kas naa Era eve ei ngle alue actor tlre N Genin LENG ee i Degree dBuV dB m 1 11284 2649QP 40 00 13 51 400H 132 4354 17 05 _ 4 24826 3049QP 47 00 1651 300H 134 4447 13 98 Cs row feza ao rr eon we m em 16 77000 3846QP 4700 Remarks 1 Emission Level dBuV m Raw Value dBuV Correction Factor dB m 2 Correction Factor dB m Antenna Factor dB m Cable Factor dB Pre Amplifier Factor dB 3 The other emission levels were very low against the limit 4 Margin value Emission level Limit value Level dBuV m 90 a0 70 6 amp 0 50 6 40 3 4 0 I I I I I I I 30 100 200 300 400 500 600 TOO B00 900 1000 Frequency MHz Report No CE141111C02 1 25 of 56 Report Format Version 5 0 4 Detector Function amp Frequency Range 30MHz 1GHz Bandwidth Quasi Peak QP 120kHz Input Power 230Vac 50Hz son ees 23 C 64 RH Conditions Tested by Scott Yang Test Date 2014 11 20 Antenna Polarity amp Test Distance Vertical at 10 m Antenna Polarity amp
3. Air Discharge 2 4 8 kV Direct Contact Discharge 2 4 6 kV Direct Indirect Polarity Positive amp Negative Number of Discharge Minimum 20 times at each test point Discharge Mode Single Discharge Discharge Period 1 second minimum 5 4 2 TEST INSTRUMENTS Description amp Manufacturer Model No Cal Date Electronic Discharge Simulator MZ 151EC 0310225 Jun 09 2014 Jun 08 2015 KeyTek Notes 1 The test was performed in Hwa Ya ESD Room 4 2 The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA Report No CE141111C02 1 29 of 56 Report Format Version 5 0 4 5 4 3 TEST PROCEDURE The discharges shall be applied in two ways a Contact discharges to the conductive surfaces and coupling planes The EUT shall be exposed to at least 200 discharges 100 each at negative and positive polarity at a minimum of four test points One of the test points shall be subjected to at least 50 indirect discharges to the center of the front edge of the horizontal coupling plane The remaining three test points shall each receive at least 50 direct contact discharges If no direct contact test points are available then at least 200 indirect discharges shall be applied in the indirect mode Test shall be performed at a maximum repetition rate of one discharge per second Air discharges at slots and apertures and insulating surfaces On th
4. Date 2015 1 7 Environmental 5 25 C 95 RH Tested by Vincent Yang E Applied Field Test Performance ROEM E V m Distance m gister Criterion 50 1000 0 90 180 270 1 Nat A 800 1000 0 90 180 270 20 175 Noe A 1400 2100 0 90 180 270 2100 2500 0 90 180 270 The EUT was tested with ground cable Note 1 The EUT function was correct during the test Report No CE141111C02 1 38 of 56 Report Format Version 5 0 4 5 6 ELECTRICAL FAST TRANSIENT EFT 5 6 1 TEST SPECIFICATION Basic Standard EN 61000 4 4 Test Voltage Power Line 2 kV oignal line 2 kV Polarity Positive amp Negative Impulse Frequency 5 kHz Impulse Waveshape 5 50 ns Burst Duration 15 ms Burst Period 300 ms Test Duration 1 min 5 6 2 TEST INSTRUMENT Description amp Manufacturer Model No Cal Date VPET EST TRA2000EFT C1 623 May 16 2014 May 15 2015 Generator EM CN EFT1000 May 16 2014 May 15 2015 Capacitive Coupling clamp EFT Adapter WONPRO EF 1Ada 001 Software EMC Partner GENECS NA NA Notes 1 The test was performed in Hwa Ya EFT Room 1 2 The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA 5 6 3 TEST PROCEDURE a Both positive and negative polarity discharges were applied b The distance between any coupling devices and 0 5 0 0 1 m for table top equipment testing and 1 0 0 1
5. EMISSION MEASUREMENT eee 16 4 1 2 TEST INSTRUMENTS eeeet kaiba tette tret 17 4 1 3 TEST PROCEDURE 2221210210 0NA NANA AA 17 4 1 4 DEVIATION FROM TEST STANDARD cccccccscssesecsesessessesssesssseesessesteseesesteseeeseeses 17 4 1 5 TEST SETUP tette ttr tec 18 4 1 6 EUT OPERATING CONDITIONS cccccccccssssssecscssesecsessesessessssessssesessessseesesteseesestesen 18 A 1 7 TEST RESULTS coccccccccccccccsssssscssssessesssssesesssssesessessesesssssesessestssesssstesessesteseeseateseeteseeses 19 42 RADIATED EMISSION MEASUREMENT FOR ENCLOSURE PORT uma 21 4 2 1 LIMITS OF ENCLOSURE PORT rec 21 4 2 2 TEST INSTRUMENTS eeette tette ttc 22 426 TEST PROCEDURE cR REONMUEIUNMESUM EEUU UI AE E 23 4 24 DEVIATION FROM TEST STANDARD cccccccscssssecsesessessesessessssessessestssessesteseeeeeesee 23 4 25 TEST SETUP coccccccccccccsssscsssscssesssssssesssesesesssssesessestesecssaresesseavesesssavesessestesteseevesessestevess 24 4 2 6 EUT OPERATING CONDITIONS cccccccccssssssecscssesecsessesecsessssesscssesesseeesessesteseeseatesen 24 42 7 TEST RESULTS cocccccccccccsccssssssesssscssesssssesessssscsessessesesusecssesssstssesssstesessesteseeseateaeateaeeses 25 5 VONIN tette tette ttt 27 54 GENERAL DESCRIPTION tette tret 27 5 2 GENERAL PERFORMANCE CRITERIA DESCRIPTION eee 28 53 EUT OPERATING CONDITION eerte ted 28 54 ELECTROSTATIC DISCHARGE IMMUNITY TEST ESD eee 29 54 1 TEST SPEC
6. EN 61000 4 3 2006 A1 2008 A2 2010 EN 61000 4 4 2012 EN 61000 4 5 2006 EN 61000 4 6 2014 Note The above EN basic standards are applied with latest version if manufacturer has no special requirement All tests have been performed and recorded as per the above standards Report No CE141111C02 1 8 of 56 Report Format Version 5 0 4 3 4 DESCRIPTION OF SUPPORT UNITS The EUT has been tested as an independent unit together with other necessary accessories or support units The following support units or accessories were used to form a representative test configuration during the tests Emission tests X Model No FCCID CN082WXD 72872 24 LCD MONITOR DELL 2410 FCC DoC Approved OCR 06DL CN 05V23T 71581 1 Keyboard DELL KB4021 FCC DoC Approved AK 01Q2 A01 CN 011D3V 71581 C MOUSE DELL MS111 P FCC DoC Approved 1CJ 0195 D EARPHONE PHILIPS HL145 NA NA PRINTER EPSON MEEZO70220 FCC DoC Approved o o lt WDBACY5000AB F External Hard Disk WD L01 WX51C12T6215 NA G MODEM ACEEX 1414V 0401008278 IFAXDMidMd oO H MODEM ACEEX 1414V 3 0401008252 IFAxDM1414_ f ooo i MODEM ACEEX 1414V 8 0401008241 IFaxom1a1a f ooo J MODEM ACEEX 1414V 3 0401008279 IFAXDMidMMd fe K Notebook DELL Latitude E6420 HPFCSQ FCC DoC Approve WATYK9CQCJSKS3K Notebook DELL PP02X QDS BRCM1005 D CBRXTRFWYRB Note 1 All power
7. H patterns to monitor and monitor displayed them EUT sent H patterns to printer and printer printed them EUT sent H patterns to modems EUT performed R W function with HDD EUT sent audio signal to earphone EUT linked with notebooks through LAN nm D OO O Q9 Report No CE141111C02 1 18 of 56 Report Format Version 5 0 4 4 1 7 TEST RESULTS S Detector Function Quasi Peak QP Frequency Range 150kHz 30MHz amp Bandwidth Average AV 9kHz Input Power 230Vac gt 50Hz DULL 23 C 644RH Conditions Tested by Scott Yang TestDate Date TestDate 2014 11 24 Phase Of Power Line L Frequency Correction Reading Value Emission Level Limit Margin Factor a EE ED MA RE ME NN MHz E 0 15000 e a a 99 00 47 ETE 0 23203 41 44 41 72 99 00 57 28 ES 0 45859 31 22 31 52 99 00 67 48 Ka 4 51953 27 71 28 15 93 00 64 85 6 22 74609 37 15 37 71 93 00 55 29 Remarks 1 Q P and AV are abbreviations of quasi peak and average individually 2 The emission levels of other frequencies were very low against the limit 3 Margin value Emission level Limit value 4 Correction factor Insertion loss Cable loss 5 Emission Level Correction Factor Reading Value LLLA dr wl H 4 ol Ith EN wl ll RN 2 11 HE wl ll MEM ot Bd te ERE Zo Ball AL EH Ir UM ot tt LIE Report No CE141111C02 1 19 of 56 Report Form
8. Report Format Version 5 0 4 4 2 2 TEST INSTRUMENTS Description amp Model No Serial No Cal Date Cal Due Manufacturer Test Receiver ROHDE amp SCHWARZ ESR 7 101240 Sep 29 2014 Sep 28 2015 V Test Receiver ROHDE amp SCHWARZ ESR 7 101264 Nov 29 2013 Nov 28 2014 H BILOG Antenna SCHARZBEC INA VULB9168 9168 148 Feb 25 2014 Feb 24 2015 BILOG Antenna SCHWARZBEC MIR VULB9168 9168 149 Feb 25 2014 Feb 24 2015 Arie 8447D 2944A10636 Oct 18 2014 Oct 17 2015 Agilent V rear 8447D 2944A10637 Oct 18 2014 Oct 17 2015 Agilent H Preemie 8449B 3008A01959 Oct 18 2014 Oct 17 2015 Agilent RF signal cable 8D FB Cable CH H 01 Oct 25 2014 Oct 24 2015 Woken V RF pa m 8D FB Cable CH V Oct 25 2014 Oct 24 2015 Woken EE BV ADT Radiated BV ADT V 8 7 07 Antenna Tower V MFA 440 9707 m Antenna Tower H DS430 50303 NA M Controle V MF7802 074 NA MNM Controller H MF7802 08093 Notes 1 The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA 2 The test was performed in HwaYa Chamber 1 3 The FCC Site Registration No is 477732 4 The IC Site Registration No is IC 7450F 1 5 The VCCI Site Registration No is R 1893 Report No CE141111C02 1 22 of 56 Report Format Version 5 0 4 4 2 3 TEST PROCEDURE a The EUT was placed on the top of a rotati
9. Series SPC 2145 SPC 2845 WA SPC 2845X SPC 2845R SPC 2845D BERESIMODEE SPC XXXXXXXXXX X can be 0 9 A Z or blank for marketing purpose NOTE 1 The EUT uses following adapter 2 All models are electrically identical different model names are for marketing purpose Model SPC 2845 is the representative for final test Vecow SPC Series SPC 2845 SPC 2145 S V ecow S PC 2845 W4 SPC 2845R SPC 2845D SPC XXXXXXXXXX X can be 0 9 A Z or blank for marketing purpose 3 The above EUT information is declared by manufacturer and for more detailed feature description please refer to the manufacturer s specifications or user s manual PC 2845X Report No CE141111C02 1 7 of 56 Report Format Version 5 0 4 3 2 DESCRIPTION OF TEST MODES Test modes are presented in the report as below Test Condition Conducted emission test DVI 1920 1200 60Hz LAN 1 1Gbps LAN 2 1Gbps Radiated emission test DVI 1920 1200 60Hz LAN 1 1Gbps LAN 2 1Gbps Immunity tests DVI 1920 1200 060Hz LAN 1 1Gbps LAN 2 1Gbps 3 3 GENERAL DESCRIPTION OF THE APPLIED STANDARD The EUT is a kind of railway application equipments and according to the specification of the EUT declared by manufacturer it must comply with the requirements of the following standards EN 50155 2007 AC 2010 AC 2012 Clause 12 2 7 amp 12 2 8 EN 50121 3 2 2006 AC 2008 EN 55011 2009 A1 2010 EN 61000 4 2 2009
10. Test Distance Verticalat10m Frequency Emission Limit Margin Antenna Table Raw Correction MHz Level dBuV m dB P Angle Value Factor dBuV m mo dBuV dB m 3844 3179QP 4000 8 21 _ KTA 14 81 LIE ME BE AK AN IMME RC E 6 770 00 4193QP 4700 507 2 307 Remarks 1 Emission Level dBuV m Raw Value dBuV Correction Factor dB m 2 Correction Factor dB m Antenna Factor dB m Cable Factor dB Pre Amplifier Factor dB 3 The other emission levels were very low against the limit 4 Margin value Emission level Limit value Level dBuV im 90 a0 T0 60 50 40 ib 3 4 EN TIE UL LLL LL BELL HE LH LH LT 10 0 7 I I I I I I I I I I 30 100 300 400 500 600 TOO 900 1000 Frequency MHz Report No CE141111C02 1 26 of 56 Report Format Version 5 0 4 5 IMMUNITY TEST 5 1 GENERAL DESCRIPTION Product standard EN 61000 4 2 EN 61000 4 3 Basic standard Specification requirement and EN 61000 4 4 Performance criteria EN 61000 4 5 EN 61000 4 6 Electrostatic Discharge ESD 8 kV air discharge 6 kV contact discharge Performance Criterion B Radio Frequency Electromagnetic Field Susceptibility Test RS 80 1000 MHz 20 V m 80 AM 1 kHz 800 1000 MHz 20 V m 80 AM 1 kHz 1400 2100 MHz 10 V m 80 AM 1 kHz 2100 2500 MHz 5 V m 80 AM 1 kHz Performance Criterion A Electrical Fast Transient Burst EFT Power lin
11. above support units are non shielded 1 8m 2 Items K L acted as communication partners to transfer data Shielding x Ka Cores Remarks Yes No 3 2 Provided Provided by manufacturer manufacturer Hn RN USB USB Earphone USB Ew 2 3 4 5 6 USB o 7 RS 232 8 RJ45 Catse 2 wo n o jnyferESD sSurge tests NO 9 RJ45 Catse 2 1 y 0 JonyforRS EFT CS tests 10 Ground 1 18 Y o JOnyforRS EFT tests Note The core s is are originally attached to the cable s NO Report No CE141111C02 1 10 of 56 Report Format Version 5 0 4 3 5 CONFIGURATION OF SYSTEM UNDER TEST Conducted emission test 1 Console s Monitor A 2 USB 6 Printer E 7 Earphone D a A En Modem J Adapter EUT Remote site Notebook K L Report No CE141111C02 1 11 of 56 Report Format Version 5 0 4 Radiated emission test 1 Console ay Monitor A 5 2 USB Printer E Keyboard B a 6 HDD F Mouse C 7 0 7 Modem G H 1 8 Modem J Adapter EUT 9 Notebook K L Report No CE141111C02 1 12 of 56 Report Format Version 5 0 4 ESD Surge tests Monitor A Keyboard B Mouse C 3 Earphone D Adapter EUT HDD E 6 HDD F RS 232 x4 L Modem G H 1 J 8 Remote site Notebook K L Report No CE141111C
12. repeated until all discharges were complete At least ten single discharges in the most sensitive polarity were applied to the Horizontal Coupling Plane at points on each side of the EUT The ESD generator was positioned horizontally at a distance of 0 1 meters from the EUT with the discharge electrode touching the HCP At least ten single discharges in the most sensitive polarity were applied to the center of one vertical edge of the Vertical Coupling Plane in sufficiently different positions that the four faces of the EUT were completely illuminated The VCP dimensions 0 5m x 0 5m was placed vertically to and 0 1 meters from the EUT Report No CE141111C02 1 30 of 56 Report Format Version 5 0 4 5 4 4 DEVIATION FROM TEST STANDARD No deviation 5 4 5 TEST SETUP Vertical coupling plane 0 5mm Isolation Support ESD Generator Nearest Ad Wall Horizontal coupling plane Ground Reference Plane For the actual test configuration please refer to the related item Photographs of the Test Configuration NOTE TABLE TOP EQUIPMENT The configuration consisted of a wooden table 0 8 meters high standing on the Ground Reference Plane The GRP consisted of a sheet of aluminum at least 0 25mm thick and 2 5 meters square connected to the protective grounding system A Horizontal Coupling Plane 1 6m x 0 8m was placed on the table and attached to the GRP by means of a cable with 9
13. 014 Jul 09 2015 BV ADT Cond Notes 1 The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA 2 The test was performed in HwaYa Shielded Room 2 3 The VCCI Site Registration No is C 2047 4 1 3 TEST PROCEDURE a The EUT was placed 0 4 meters from the conducting wall of the shielded room with EUT being connected to the power mains through a line impedance stabilization network LISN Other support units were connected to the power mains through another LISN The two LISNs provide 50 Ohm 50uH of coupling impedance for the measuring instrument b Both lines of the power mains connected to the EUT were checked for maximum conducted interference c The frequency range from 150 kHz to 30 MHz was searched Emission levels under Limit 20dB was not recorded 4 1 4 DEVIATION FROM TEST STANDARD No deviation Report No CE141111C02 1 17 of 56 Report Format Version 5 0 4 4 1 5 TEST SETUP Vertical Ground Reference Plane Test Receiver pang CREER EUT O OO o 40cm go e 80cm LISN d Ni Horizontal Ground Reference Plane Note 1 Support units were connected to second LISN 2 Both of LISNs AMN are 80 cm from EUT and at least 80 cm from other units and other metal planes For the actual test configuration please refer to the related item Photographs of the Test Configuration 4 1 6 EUT OPERATING CONDITIONS EUT sent
14. 02 1 13 of 56 Report Format Version 5 0 4 RS EFT tests Monitor A a Keyboard B e Mouse C 3 4 Earphone D Adapter EUT Notebook K L HDD E HDD F Modem G H 1 J Remote site Report No CE141111C02 1 14 of 56 Report Format Version 5 0 4 CS test Monitor A Keyboard B Mouse C 3 Earphone D Adapter EUT HDD E 6 HDD F RS 232 x4 L Modem G H 1 J 9 Remote site Notebook K L Report No CE141111C02 1 15 of 56 Report Format Version 5 0 4 4 EMISSION TEST 4 1 CONDUCTED EMISSION MEASUREMENT 4 1 1 LIMITS OF CONDUCTED EMISSION MEASUREMENT TEST STANDARD EN50121 3 2 0 009 0 15 See note 1 amp 2 01505 99 Seenote3 4 amp 5 0 5 30 See note 3 4 amp 5 NOTE 1 At present there are no limits for conducted emissions from 9 kHz to 150 kHz Limiting conducted emissions from an apparatus will prevent excessive radiated emissions Experience in this technique and the relationship between conducted and radiated emissions is necessary in order to progress this standard in the future 2 230 V AC power outlet ports for public use shall offer a power quality which is sufficient for the use of intended equipment like PC and mobile telephone chargers The harmonic distortion in differential and common mode shall be limited by a sine filter to 5 Yo The burst and surge emissions of the outlet have to
15. 40kQ total impedance The equipment under test was installed in a representative system as described in section 7 of EN 61000 4 2 and its cables were placed on the HCP and isolated by an insulating support of 0 5mm thickness A distance of 1 meter minimum was provided between the EUT and the walls of the laboratory and any other metallic structure Report No CE141111C02 1 31 of 56 Report Format Version 5 0 4 5 4 6 TEST RESULTS Input Power 230 Vac 50 Hz Test Date 2014 11 27 22 C 53 RH Environmental Conditions 988 mbar Tested by Test Results of Direct Application pee prn Contact Performance mE MN LE Net NA CH A Note NR 46 8 PNoe3 NA B 248 9 NA Note A 24 10 1 NA Noted Co AD L8 nm m nte B Note 1 Nt 8B Description of test points of direct application Please refer to following page for representative mark only Test Results of Indirect Application Discharge Polarity Test Point Horizontal Vertical Coupling Performance Level kV Coupling Plane Plane Criterion ae Se a Description of test points of indirect application 1 Front side 2 Rear side 3 Right side 4 Left side Note 1 The EUT function was correct during the test 2 The EUT USB HDD R W function held during the test but could self recover after the test 3 The LAN PING had request time out message during the test but could self recover a
16. 41111C02 1 41 of 56 Report Format Version 5 0 4 5 7 SURGE IMMUNITY 5 7 1 TEST SPECIFICATION Basic Standard EN 61000 4 5 Wave Shape Combination Wave 1 2 50 us Open Circuit Voltage 8 20 us Short Circuit Current 1 2 50 us Wave for signal lines 8 20 us Short Circuit Current Test Voltage Power Line 0 5 1 2 kV Signal Line NA Polarity Positive Negative Phase Angle 0 90 180 270 Pulse Repetition Rate 1 time 60 sec Number of Tests 5 positive and 5 negative at selected points 5 7 2 TEST INSTRUMENT Description amp Manufacturer Model No Cal Date Modular Impulse Generator EMC Partner MIGO603IN3 Sep 02 2014 Sep 01 2015 Universal Surge Coupling De Coupling Network CDN UTP8 011 Sep 02 2014 Sep 01 2015 EMC Partner Surge Adapter WONPRO SU1 Ada 001 Coupling and Decoupling Network CDN2000 06 32 093 NA NA EMC PARTNER Notes 1 The test was performed in Hwa Ya Surge Room 2 2 The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA Report No CE141111C02 1 42 of 56 Report Format Version 5 0 4 5 7 3 TEST PROCEDURE a For EUT power supply The surge is to be applied to the EUT power supply terminals via the capacitive coupling network Decoupling networks are required in order to avoid possible adverse effects on equipment not under test that may be powered by the same lines and to provide suffici
17. 9 A Z or blank for marketing purpose Vecow Co Ltd Nov 20 2014 Jan 07 2015 ENGINEERING SAMPLE EN 50155 2007 AC 2010 AC 2012 Clause 12 2 7 amp 12 2 8 EN 50121 3 2 2006 AC 2008 EN 55011 2009 A1 2010 EN 61000 4 2 2009 EN 61000 4 3 2006 A1 2008 A2 2010 EN 61000 4 4 2012 EN 61000 4 5 2006 EN 61000 4 6 2014 The above equipment model SPC 2845 has been tested by Bureau Veritas Consumer Products Services H K Ltd Taoyuan Branch and found compliance with the requirement of the above standards The test record data evaluation amp Equipment Under Test EUT configurations represented herein are true and accurate accounts of the measurements of the sample s EMC characteristics under the conditions specified in this report PREPARED BY yz j DATE Jan 09 2015 Suntee Liu Specialist APPROVED BY KA DATE Jan 09 2015 Ken Liu Senior Manager Report No CE141111C02 1 5 of 56 Report Format Version 5 0 4 2 SUMMARY OF TEST RESULTS The EUT has been tested according to the following specifications Test Type Result Remarks Meet the requirement of limit Auxiliary a c or d c power port Minimum passing margin is EN 55011 2009 47 05dB at 0 15000MHz A1 2010 Meet the requirement of limit Enclosure port Minimum passing margin is 5 07dB at 770 00MHz IMMUNITY Test Type Result Remarks El ic disch M h f EN 61000 4 2 2009 Eee discharge P
18. ASS eets the FEQ Mrenents O immunity test Performance Criterion B Radiated radio frequency electromagnetic field immunity test EN 61000 4 3 2006 A1 2008 A2 2010 Meets the requirements of Performance Criterion A Electrical fast transient burst Meets the requirements of EN 61000 4 4 2012 PASS Performance Criterion A ity test pany Judged by manufacturer Meets the requirements of EN 61 4 5 2 61000 4 5 2006 Surge immunity test PASS ere mance Uis Immunity to conducted EN 61000 4 6 2014 disturbances induced by radio frequency fields Meets the requirements of Performance Criterion A 2 1 MEASUREMENT UNCERTAINTY Where relevant the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16 4 2 This uncertainty represents an expanded uncertainty expressed at approximately the 95 confidence level using a coverage factor of k 2 Uncertainty Conducted emission 150kHz 30MHz 2 44dB Radiated emission 30MHz 1GHz 4 70dB The listed uncertainties are the worst case uncertainty for the entire range of measurement Please note that the uncertainty values are provided for informational purposes only and are not used in determining the PASS FAIL results Report No CE141111C02 1 6 of 56 Report Format Version 5 0 4 3 GENERAL INFORMATION 3 1 GENERAL DESCRIPTION OF EUT PRODUCT Ultra Compact Embedded System TEST MODEL SPC 2845 Vecow SPC
19. IFICATION cccccccsssscsecsessesesssssesecssssesesssesesessearesessessesessessestsatsveseseseeseeees 29 54 2 TEST INSTRUMENTS 122225201210000 AALALA kba kababasa mamana 29 54 3 TEST PROCEDURE 22121121000 M ASA NAAALALA kasb 30 5 4 4 DEVIATION FROM TEST STANDARD cccccsccsssecsessesessessesecsessesessessestsseessesseesseeees 31 54 5 TEST SETUP cocccccccccccscsccscssssessessssesscssesessesvesecsesseseacsresessessssessessestesesssatesessesteseeseaeeees 31 54 6 TEST RESULTS o cccccccccccscsssscsssssssessessesessessesecsesseseeseasesessessesessessesessessestssestssesseeteseeees 32 5 5 RADIATED RADIO FREQUENCY ELECTROMAGNETIC FIELD IMMNITY TEST EG E E E E E A A 36 Report No CE141111C02 1 2 of 56 Report Format Version 5 0 4 5 5 1 5 5 2 5 5 3 5 5 4 5 5 5 5 5 6 5 6 5 6 1 5 6 2 5 6 3 5 6 4 5 6 5 5 6 6 5 7 5 7 1 5 1 2 5 7 3 5 7 4 Suid 5 7 6 5 8 5 8 1 5 8 2 5 8 3 5 8 4 5 8 5 5 8 6 ES SPECIPICAT TO 36 TESTIN S TREME NT S 36 BES PROCEDURE orrn a AA AA NA AA AA 37 DEVIATION FROM TEST STANDARD seeseseeeeeeenmem enne 37 NEST cas pen AINA AA AA ANA 37 ES RE UCI O a E E T E es 38 ELECTRICAL FAST TRANSIENT EFT seeeeeeeemmen 39 TEST SPECIFIC AHO 39 TES Iibmaqee c S 39 MSN OC 25 0 E X 39 DEVIATION FROM TEST STANDARD sseseseeee
20. a ie Nov 13 2015 Notes 1 The test was performed in Hwa Ya CS Room 1 2 The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA Report No CE141111C02 1 46 of 56 Report Format Version 5 0 4 5 8 3 TEST PROCEDURE a The EUT shall be tested within its intended operating and climatic conditions b An artificial hand was placed on the hand held accessory and connected to the ground reference plane c One of the CDNs not used for injection was terminated with 50 Q providing only one return path All other CDNs were coupled as decoupling networks d The frequency range is swept from 150 kHz to 80 MHz using the signal level established during the setting process and with a disturbance signal of 80 Yo amplitude The signal is modulated with a 1 kHz sine wave pausing to adjust the RF signal level or the switch coupling devices as necessary Where the frequency is swept incrementally the step size shall not exceed 196 of the preceding frequency value e The dwell time of the amplitude modulated carrier at each frequency shall not be less than the time necessary for the EUT to be exercised and to respond but shall in no case be less than 0 5 s The sensitive frequencies e g clock frequencies shall be analyzed separately f Attempts should be made to fully exercise the EUT during testing and to fully interrogate all exercise modes selected f
21. at Version 5 0 4 S Detector Function Quasi Peak QP Frequency Range 150kHz 30MHz amp Bandwidth Average AV 9kHz Input Power 230Vac gt 50Hz LLL LL 64 RH Conditions Tested by Scott Yang Test Date 2014 11 21 Du d ur EM WEN UN No Factor dBuV dBuV dBuV dB MHz B QP QP QP QP 4 70313 31 57 32 02 93 00 60 98 6 22 33203 35 93 36 54 93 00 56 46 Remarks 1 Q P and AV are abbreviations of quasi peak and average individually 2 The emission levels of other frequencies were very low against the limit 3 Margin value Emission level Limit value 4 Correction factor Insertion loss Cable loss 5 Emission Level Correction Factor Reading Value BE EE TRASNITE KIT pq gy 3 LX LI LP gg lah Report No CE141111C02 1 20 of 56 Report Format Version 5 0 4 4 2 RADIATED EMISSION MEASUREMENT FOR ENCLOSURE PORT 4 2 1 LIMITS OF ENCLOSURE PORT TEST STANDARD EN 50121 3 2 Test Specification Standard Test set up 30 MHz 230 MHz 40 dByV m quasi peak Note 1 amp 2 Enclosure EN 55011 230 MHz 1 GHz 47 ABuV m quasi peak Note 1 amp 2 NOTE 1 Measurement distance is 10 m A measurement distance of 3 m may be used with the limit increased by 10 dB 2 Traction converters and auxiliary converters over 50 kVA need not be tested individually but when the vehicle is tested as a whole in accordance with EN 50121 3 1 Report No CE141111C02 1 21 of 56
22. be limited to the levels of residential equipment according to EN 61000 6 1 AM radio receivers are not intended to be supplied by these power outlets 3 Wherever applicable the method defined by EN 55011 is to be used At present the existing method of measuring conducted emissions EN 55011 has limitations in terms of voltage and current rating of coupling networks In addition the method of measuring voltage has safety implications for testing high power systems Limiting conducted emissions from apparatus connected to external cable systems will prevent excessive radiated emissions 4 This requirement refers to the industrial limit values but considering they have been defined to protect radio and TV sets and as the objective is not the same here the applicable limit for railway applications have been relaxed by 20 dB to be more representative of potential problems 9 his requirement is not applicable to power ports which are connected to other dedicated compatible ports Report No CE141111C02 1 16 of 56 Report Format Version 5 0 4 4 1 2 TEST INSTRUMENTS Description amp Manufacturer ROHDE amp SCHWARZ RF signal cable Woken LISN ROHDE amp SCHWARZ EUT LISN ROHDE amp SCHWARZ Peripheral ooftware ADT Model No Serial No Cal Date ESCS30 100288 Apr 24 2014 Apr 23 2015 5D FB Cable HYCO2 01 Dec 27 2013 Dec 26 2014 ESH2 Z5 100100 Dec 23 2013 Dec 22 2014 ESH3 Z5 100312 Jul 10 2
23. cords of the above support units are non shielded 1 8m 2 Items K L acted as communication partners to transfer data m Shielding Descriptions Qty Length m Cores Qty Remarks Yes No t pv 3 418 Y 2 Provided by manufacturer Earphone USB 6 USB RS 232 8 RS 232 9 RJ45 Cat5e NO 2 o n o l0nlyforRaciated emission test 10 RS 232 o1 2 Y 0 pr 0 Jg RJ45 Cat5e 2 w Y 20 JOnyforConducted emission test Note The core s is are originally attached to the cable s Report No CE141111C02 1 9 of 56 Report Format Version 5 0 4 Immunity tests e Lom Model No FCCID CN 0YY528 46633 24 LCD Monitor DELL 2407WFPb FCC DoC Approved 76I 1E7S CN 05V23T 71581 1 Keyboard DELL KB4021 FCC DoC Approved AK 01KZ A01 CN 011D3V 71581 MOUSE DELL MS111 P FCC DoC Approved 1CJ 093U LUE E CIN a ON OO E HardDisk ADATA HV620 1E3620122277 NA O F Harddisk ADATA HV620 1E3620122207 NA G MODEM ACEEX 1414V 3 0401008252 IFAxDM1414 f o ooo H MODEM ACEEX 1414V 3 0401008253 IFaxom1a14 f o ooo i MODEM ACEEX 1414V 8 0401008270 IFAXDMidMMd fe J MODEM ACEEX 1414V 3 0401008208 IFAxDM1414 f o ooo K Notebook Del E540 S5cbsS FCC Doc Approve L Notebook Del E5420 55CF4S1 j FCCDoCAppoved Note 1 All power cords of the
24. e 2kV Signal line 2kV Performance Criterion A Surge Immunity Test 1 2 50 us Open Circuit Voltage Power Line line to line 1 kV line to ground 2 kV Performance Criterion B Conducted Radio Frequency Disturbances Test CS 0 15 80 MHz 10Vrms 80 AM 1kHz Performance Criterion A NOTE 1 This limit applies to equipment mounted in the passenger compartments drivers cab or external to the rolling stock roof underframe For equipment mounted in all other areas a severity level of 10 V m may be used Report No CE141111C02 1 27 of 56 Report Format Version 5 0 4 5 2 GENERAL According to EN criteria PERFORMANCE CRITERIA DESCRIPTION 50121 1 standard the following describes the general performance A functional description and a definition of performance criteria during or as a consequence of the EMC testing shall be provided by the manufacturer and noted in the test report CRITERION A CRITERION B based on the following criteria The apparatus shall continue to operate as intended during and after the test No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer when the apparatus is used as intended The performance level may be replaced by a permissible loss of performance If the minimum performance level or the permissible performance loss is not specified by the manufacturer either of these may be derived from the product d
25. enme eene 40 Racy SETOR 2 ee 40 TE STRE p 41 rcasuhuB gp e 42 ES SPECIFIC AH O P E 42 TES TINS TRUME NT e 42 NEST PROCEDURE srne E E NGANGA 43 DEVIATION FROM TEST STANDARD seeriaga n SE EE E E 43 TEST ETUR AA AA AA AA AP 44 ESP RES UEP NAP ANAN DANAO ALA AA 44 CONDUCTED RADIO FREQUENCY DISTURBANCES CS eeeeeeeseee 45 TEST SPECIFICA TO 45 TESTIN STROME NAA ANAND NAUNA AA 46 ES PROCEDURE aa NAA AA AA 47 DEVIATION FROM TEST STANDARD 0 00cccccceeeeee ee eeee cece eater ee aaeeeeeeeaaeeeeeeeeeeeeeeas 47 NEST ETOF 48 ES RE UET O GAPAN PA AA AA AA 49 PHOTOGRAPHS OF THE TEST CONFIGURATION 1100210000000 aa nananana naana a aksann anna 50 INFORMATION ON THE TESTING LABORATORIES eee 56 Report No CE141111C02 1 3 of 56 Report Format Version 5 0 4 RELEASE CONTROL RECORD ISSUENO REASON FOR CHANGE DATE ISSUED CE141111C02 1 Original release Jan 09 2015 Report No CE141111C02 1 4 of 56 Report Format Version 5 0 4 1 CERTIFICATION PRODUCT BRAND TEST MODEL SERIES MODEL APPLICANT TESTED TEST SAMPLE STANDARD Ultra Compact Embedded System Vecow SPC 2845 Vecow SPC Series SPC 2145 SPC 2845 W4 SPC 2845X SPC 2845R SPC 2845D SPC XXXXXXXXXX X can be 0
26. ent decoupling impedance to the surge wave The power cord between the EUT and the coupling decoupling networks shall be 2 meters in length or shorter For double insulated products without PE or external earth connections the test shall be done in a similar way as for grounded products but without adding any additional external grounded connections If there are no other possible connections to earth line to ground tests may be omitted b For test applied to unshielded unsymmetrically operated interconnection lines of EUT The surge is applied to the lines via the capacitive coupling The coupling decoupling networks shall not influence the specified functional conditions of the EUT The interconnection line between the EUT and the coupling decoupling networks shall be 2 meters in length or shorter c For test applied to unshielded symmetrically operated interconnection telecommunication lines of EUT The surge is applied to the lines via gas arrestors coupling Test levels below the ignition point of the coupling arrestor cannot be specified The interconnection line between the EUT and the coupling decoupling networks shall be 2 meters in length or shorter 5 7 4 DEVIATION FROM TEST STANDARD No deviation Report No CE141111C02 1 43 of 56 Report Format Version 5 0 4 5 7 5 TEST SETUP Combination Wave Generator Coupling amp Dec ouplin eN etw ork For the actual test configuration please ref
27. eport to notify us of any material error or omission caused by our negligence provided however that such notice shall be in writing and shall specifically address the issue you wish to raise A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report the tests conducted and the correctness of the report contents Unless specific mention the uncertainty of measurement has been explicitly taken into account to declare the compliance or non compliance to the specification The report must not be used by the client to claim product certification approval or endorsement by any government agencies Report No CE141111C02 1 1 of 56 Report Format Version 5 0 4 Table of Contents RELEASE CONTROL RECORD ettet tette 4 1 CERTIFICATION D 5 2 SUMMARY OF TEST RESULTS cccccssssssessssessesssscssessesessessssesessesesessestesesseatesesseaeeees 6 2 1 MEASUREMENT UNCERTAINTY eee tette 6 3 GENERAL INFORMATION basbas tette tette 7 31 GENERAL DESCRIPTION OF EUT ete tette 7 32 DESCRIPTION OF TEST MODES eetee teet 8 33 GENERAL DESCRIPTION OF THE APPLIED STANDARD 8 34 DESCRIPTION OF SUPPORT UNITS eetee tete 9 35 CONFIGURATION OF SYSTEM UNDER TEST ul ankas 11 4 ISON tette tet ttt ted 16 441 CONDUCTED EMISSION MEASUREMENT ccccccssssssessesessecsesseseesessessesesseseeseeee 16 4 1 1 LIMITS OF CONDUCTED
28. er to the related item Photographs of the Test Configuration 5 7 6 TEST RESULTS Input Power 230 Vac 50 Hz Test Date 2014 11 29 Environmental Conditions 23 C 53 RH Tested by Power port Voltage kV Test Point Polarity Performance Criterion L1 L2 pote Noted A 0 5 1 2 L1 PE Noted A 0 5 1 2 L2 PE ae Note 1 The EUT function was correct during the test Report No CE141111C02 1 44 of 56 Report Format Version 5 0 4 5 8 CONDUCTED RADIO FREQUENCY DISTURBANCES CS 5 8 1 TEST SPECIFICATION Basic Standard EN 61000 4 6 Frequency Range 0 15 MHz 80 MHz Voltage Level 10 Vrms Modulation 1kHz Sine Wave 80 AM Modulation Frequency Step 1 9o of preceding frequency value Dwell Time 3 seconds Report No CE141111C02 1 45 of 56 Report Format Version 5 0 4 5 8 2 TEST INSTRUMENT Description amp Manufacturer Model No Cal Date FCC SIGNAL LINE POWER LINE COUPLING DECOUPLING FCC 801 T2 03030 Nov 07 2014 Nov 06 2015 NETWORK FCC SIGNAL LINE POWER LINE COUPLING DECOUPLING FCC 801 T4 Nov 07 2014 Nov 06 2015 NETWORK FCC SIGNAL LINE POWER LINE COUPLING DECOUPLING FCC 801 T8 03032 Nov 07 2014 Nov 06 2015 NETWORK EMI Injection Clamp F2031 23MM US Nov 07 2014 BN 06 2015 Amplifier Research DA 75A250AM2 307804 DON NIMM Power Amplifier BOONTON 4232ARF POWER METER 4232A 01 02 104302 Nov 14 2014 Nov 13 2015 ee
29. escription and documentation and from what the user may reasonably expect from the apparatus if used as intended The apparatus shall continue to operate as intended after the test No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer when the apparatus is used as intended The performance level may be replaced by a permissible loss of performance During the test degradation of performance is however allowed No change of actual operating state or stored data is allowed If the minimum performance level or the permissible performance loss is not specified by the manufacturer either of these may be derived from the product description and documentation and from what the user may reasonably expect from the apparatus if used as intended CRITERION C Temporary loss of function is allowed provided me function is self recoverable or can be restored by the operation of the controls 5 3 EUT OPERATING CONDITION a EUT sent H patterns to monitor and monitor displayed them b EUT sent H patterns to modems c EUT performed R W function with HDDs d EUT sent audio signal to earphone e EUT linked with notebooks through LAN Report No CE141111C02 1 28 of 56 Report Format Version 5 0 4 5 4 ELECTROSTATIC DISCHARGE IMMUNITY TEST ESD 5 4 1 TEST SPECIFICATION Basic Standard EN 61000 4 2 Discharge Impedance 330 ohm 150 pF Discharge Voltage
30. fter the test Report No CE141111C02 1 32 of 56 Report Format Version 5 0 4 Description of Test Points Report No CE141111C02 1 33 of 56 Report Format Version 5 0 4 Pa lt FI i LAAN S bh X Report No CE141111C02 1 34 of 56 Report Format Version 5 0 4 35 of 56 Report Format Version 5 0 4 Report No CE141111C02 1 5 5 RADIATED RADIO FREQUENCY ELECTROMAGNETIC FIELD IMMNITY TEST RS 5 5 1 TEST SPECIFICATION Basic Standard EN 61000 4 3 Frequency Range 80 MHz 1000 MHz 800 MHz 1000 MHz 1400 MHz 2100 MHz 2100 MHz 2500 MHz Field Strength 20 V m 20 V m 10 V m 5 V m Modulation 1 kHz Sine Wave 8096 AM Modulation Frequency Step 1 9o of preceding frequency value Polarity of Antenna Horizontal and Vertical Antenna Height 1 55 m Dwell Time 3 seconds 5 5 2 TEST INSTRUMENTS Description amp Manufacturer Model No Cal Date BBA Power Amp B250C125 101011 NRP Z91 101572 Jan 22 2014 Jan 21 2015 NRP Z91 101573 Jan 22 2014 Jan 21 2015 Signal Generator SMB100A 105801 Jan 16 2014 Jan 15 2015 Stacked Log Per Antenna STLP9149 9149 141 High GAIN LOG Periodic HLOAGE 100114 NA NA Antenna Notes 1 The test was performed in Hwa Ya RS Room 2 2 The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA 3 The transmit antenna was located at a d
31. inko EMC RF Lab Hsin Chu EMC RF Telecom Lab Tel 886 2 26052180 Tel 886 3 5935343 Fax 886 2 26051924 Fax 886 3 5935342 Hwa Ya EMC RF Safety Lab Tel 886 3 3183232 Fax 886 3 3270892 Email service adt tw bureauveritas com Web Site www bureauveritas adt com The address and road map of all our labs can be found in our web site also END Report No CE141111C02 1 56 of 56 Report Format Version 5 0 4
32. istance of 3 meters from the EUT Report No CE141111C02 1 36 of 56 Report Format Version 5 0 4 5 5 3 TEST PROCEDURE The test procedure was in accordance with EN 61000 4 3 a The testing was performed in a modified semi anechoic chamber b The frequency range is swept 80 MHz 1000 MHz 800 MHz 1000 MHz 1400 MHz 2100 MHz 2100 MHz 2500 MHz with the signal 80 amplitude modulated with a 1 kHz sinewave c The dwell time at each frequency shall not be less than the time necessary for the EUT to be exercised and to respond but shall in no case be less than 0 5s d The field strength level was 20V m 20V m 10V m 5V m e The test was performed with the EUT exposed to both vertically and horizontally polarized fields on each of the four sides 5 5 4 DEVIATION FROM TEST STANDARD No deviation 5 5 5 TEST SETUP RF Generator and control system Monitoring system For the actual test configuration please refer to the related item Photographs of the Test Configuration NOTE TABLETOP EQUIPMENT The EUT installed in a representative system as described in section 7 of EN 61000 4 3 was placed on a non conductive table 0 8 meters in height The system under test was connected to the power and signal wire according to relevant installation instructions Report No CE141111C02 1 37 of 56 Report Format Version 5 0 4 5 5 6 TEST RESULTS Input Power O Power 230 Vac 50 Hz Test
33. m for floor standing equipment c The duration time of each test sequential was 1 minute d The transient burst waveform was in accordance with EN 61000 4 4 5 50ns Report No CE141111C02 1 39 of 56 Report Format Version 5 0 4 5 6 4 DEVIATION FROM TEST STANDARD No deviation 5 6 5 TEST SETUP Capacitive coupling EFT B generator A uL HP l Contact to the ground Ea Insulating Coup reference plane a support Coupling o decoupling L deii EFT B Grounding connection according to network A 7 7 PP generator B the manufacturer s specification Length to ba specified in the test plan Grounding cable IEC 845 12 NOTE A location for supply line coupling B location for signal lines coupling For the actual test configuration please refer to the related item Photographs of the Test Configuration Report No CE141111C02 1 40 of 56 Report Format Version 5 0 4 5 6 6 TEST RESULTS Input Power 230 Vac 50 Hz Test Date 2014 12 21 Environmental Conditions 23 C 56 RH Tested by Andy Chang Power port C2 LiM2 ote A Note Qudgedby ep m Noen manufacturer Signal port Voltage kV Test Point Polarity Performance Criterion LAN 1 A 2 LAN 2 Note 1 a item d manufacturer The EUT was tested with ground cable Note 1 The earphone had beep during the test but could self recover after the test Report No CE1
34. ng table 0 8 meters above the ground at a 10 meter semi anechoic chamber room The table was rotated 360 degrees to determine the position of the highest radiation b The EUT was set 10 meters away from the interference receiving antenna which was mounted on the top of a variable height antenna tower c The height of antenna is varied from 1 meter to 4 meters above the ground to determine the maximum value of the field strength Both horizontal and vertical polarizations of the antenna are set to make the measurement d For each suspected emission the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned from O degrees to 360 degrees to find the maximum reading e The test receiver system was set to quasi peak detect function and specified bandwidth with maximum hold mode when the test frequency is below 1GHz NOTE The resolution bandwidth of test receiver spectrum analyzer is 120kHz for Quasi Peak QP detection at frequency below 1GHz 4 2 4 DEVIATION FROM TEST STANDARD No deviation Report No CE141111C02 1 23 of 56 Report Format Version 5 0 4 4 2 5 TEST SETUP Radio absorbing material amp iclded Case Ground Plane specirum Nga ununi i ood a m CJ Gd Gmm For the actual test configuration please refer to the related item Photographs of the Test Configuration 4 2 6 EUT OPERATING CONDITIONS Same as 4 1 6
35. on Return Performance AEE io CDN M3 EM Clamp Note1 0 15 80 LAN 1 EM Clamp CDN M3 1 3 0 15 80 LAN 2 EM Clamp CDN M3 Note 1 The EUT function was correct during the test Report No CE141111C02 1 49 of 56 Report Format Version 5 0 4 6 PHOTOGRAPHS OF THE TEST CONFIGURATION Conducted Emissions Test We ems Report No CE141111C02 1 50 of 56 Report Format Version 5 0 4 141111C02 Radiated Emissions Test CA MEE ie MERA Report No CE141111C02 1 51 of 56 Report Format Version 5 0 4 ESD Test RS Test Report No CE141111C02 1 52 of 56 Report Format Version 5 0 4 EFT Test Mains ports EFT Test Signal ports Report No CE141111C02 1 53 of 56 Report Format Version 5 0 4 Surge Test Mains ports CS Test Mains ports Report No CE141111C02 1 54 of 56 Report Format Version 5 0 4 CS Test Signal ports Report No CE141111C02 1 55 of 56 Report Format Version 5 0 4 7 INFORMATION ON THE TESTING LABORATORIES We Bureau Veritas Consumer Products Services H K Ltd Taoyuan Branch were founded in 1988 to provide our best service in EMC Radio Telecom and Safety consultation Our laboratories are accredited and approved according to ISO IEC 17025 If you have any comments please feel free to contact us at the following L
36. or susceptibility 5 8 4 DEVIATION FROM TEST STANDARD No deviation Report No CE141111C02 1 47 of 56 Report Format Version 5 0 4 CON M2 r T r777 l sala SA imi OimeL lt 03m l j To AE or i Main M l CDN T2 felecommunication lines Balanced pair fo Fe y if 7 D 5m A Mains o_ P Unscreened 7 EON a a 7 non balanced indicans NEM i cable NG F i T i 4500 D LL Py it hi CDN AF2 L i il AF T2 Insulating Support Artificial hand h 0 1 m Reference ground plane Termination 50 2 T2 Power attenuator 6 dB st generator iEC 1504 03 Note 1 The EUT clearance from any metallic obstacles shall be at least 0 5 m 2 Interconnecting cables 1 m belonging to the EUT shall remain on the insulating support For the actual test configuration please refer to the related item Photographs of the Test Configuration NOTE The equipment to be tested is placed on an insulating support of 0 1 meters height above a ground reference plane All relevant cables shall be provided with the appropriate coupling and decoupling devices at a distance between 0 1 meters and 0 3 meters from the projected geometry of the EUT on the ground reference plane Report No CE141111C02 1 48 of 56 Report Format Version 5 0 4 5 8 6 TEST RESULTS Input Power 230 Vac 50 Hz Test Date 2014 12 1 Environmental Conditions 23 C 58 RH Tested by iod uie Injecti
37. ose parts of the EUT where it is not possible to perform contact discharge testing the equipment should be investigated to identify user accessible points where breakdown may occur Such points are tested using the air discharge method This investigation should be restricted to those area normally handled by the user A minimum of 10 single air discharges shall be applied to the selected test point for each such area The basic test procedure was in accordance with EN 61000 4 2 a b Electrostatic discharges were applied only to those points and surfaces of the EUT that are accessible to users during normal operation The test was performed with at least ten single discharges on the pre selected points in the most sensitive polarity The time interval between two successive single discharges was at least 1 second The ESD generator was held perpendicularly to the surface to which the discharge was applied and the return cable was at least 0 2 meters from the EUT Contact discharges were applied to the non insulating coating with the pointed tip of the generator penetrating the coating and contacting the conducting substrate Air discharges were applied with the round discharge tip of the discharge electrode approaching the EUT as fast as possible without causing mechanical damage to touch the EUT After each discharge the ESD generator was removed from the EUT and re triggered for a new single discharge The test was