Home

English - Meuniversal

image

Contents

1. Frequency Hz i 50 60 iis Motor power kW 1 1 Absorption A 4 5 S Inlet power supply Volt dc 12 gt 3 Max air volume m h 178 50 Dust container capacity litri 5 72 Safety filter MES E gt Weight kgi 4 4 h e b gt Jf NL J L J i 300 3 5 Description of the control panel Cover IMPORTANT NEVER use the central vacuum unit without its cover because the central vacuum capacity would be missing Always make sure that it is properly installed inserting the cover spigot in the central unit upper perimeter Switch ON the switch led turns on The machine is on tension O OFF the switch led turns off The machine is out of tension Cube 03 07 01 4 INSTALLATION ATTENTION THE FOLLOWING OPERATIONS MUST BE CARRIED OUT BY QUALIFIED STAFF 4 1 Safeguards Here are some main rules to be followed in order to ensure a correct installation inside houses Installation must foresee upstream the central unit a safety bipolar switch 4 2 Area of installation Installation of a central vacuum unit presumes the existence of an aspiration pipe network installed by qualified staff that should also have spotted the best location for the central unit fixation template In case this was not carried out yet following are some suggestions for a correct installation If the central suction system has to
2. Never block the air exhaust pipes and the cooling inlets of the motor Never touch the suction accessories with any part of the body Use only one inlet at a time Do not let the central vacuum unit running if you are not utilising it and put the switch on the OFF position if you are not going to use it for a long period et mettre l interrupteur en position OFF en cas d une longue p 8eriode d arr 90t NEVER use the central unit without the dust bag cover NEVER take the central unit out from its template except for repairing carried out by qualified staff 2 HANDLING AND UNPACKING ATTENTION THE FOLLOWING OPERATIONS MUST BE CARRIED OUT BY QUALIFIED STAFF ALWAYS WEAR PROTECTIVE SHOES AND GLOVES 2 1 Handling and transport GROSS WEIGHT kg 10 PACKING DIMENSION cm 80 x 38 5 x H 31 5 CENTRAL UNIT WEIGHT kg 4 Place the central unit still packed near the location of installation The small dimensions and the light weight do not require any special handling system If necessary use a trolley or ask for somebody s help 3 Cube 03 07 V01 2 2 Unpacking It is suggested not to unpack the central unit until you put it into service in order to keep the central unit in perfect conditions ATTENTION The packing materials delivered with the central unit are inert solid wastes that must be disposed as per the regulations in force To unpack proceed as follows gt gt S gt Open the top and take out t
3. minimize the volume of WEEE entering landfills please reuse and recycle By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natural resources For more detailed information about recycling of this product please contact your local city office your household waste disposal service the shop where you purchased the product your local dealer or distributors 17 Cube 03 07 01 10 1Troubleshooting Problem No air suction in all air inlets 10 TECHNICAL PROBLEMES Cause No power in the main supply line Solution Check for the cause upstream the central unit Central unit main switch is on the OFF position Bring the main switch on to the I ON position The central unit is not correctly connected to the wall template Check the connection between the central unit and the plate The thermal relay of the motor does not work Leave the motor cooling down for a few minutes No air suction in only one inlet The power supply contacts are cut off or the microswitc of the inlet does not work Contact the Assistance Service Weak air suction Several suction inlets are used simultaneously Use only one suction inlet at a time The hose or the cleaning accessories are broken d
4. the whole operating life of the suction unit The main purpose of the user guide is to provide a correct knowledge of the user mode in order to exploit the best performance and to maintain the central suction unit at its best working and security conditions It is absolutely forbidden to duplicate copy or release totally or part of this user guide without previous written authorization by TECNOPLUS Srl owner of the trademark SISTEM AIR The manufacturer reserves the right to improve or modify the user guide and the machine itself at nay moment without prior notice 1 2 Communications to the manufacturer For any communication or request of assistance we strongly suggest to always providing the following details So to correctly identify the central vacuum unit model Central vacuum unit model Item code Serial number Year of manufacturing Purchase date Purchase place Detailed information on the arisen troubles or on the kind of information required All the technical data related to the central vacuum unit are indicated on the IDENTIFICATION PLATE situated on the central vacuum unit 1 3 Identification plate The identification plate is located inside of the unit on the front side It contains the manufacturer name the model serial number year of construction the electrical tension supply V the frequency Hz the electrical absorption A the installed power W Manufacturer name Type ___ peo VR 2 A
5. 10 10 1 INDEX General information The user guide Communications to the manufacturer Identification plate Technical Support Safety and security precautions Handling and unpacking Handling and transport Unpacking Control of accessories Description of the Central Vacuum Unit Operating principles and application field Allowed and improper use Basic Components Technical features Control panel description Installation Precautions Area of installation Installation spaces Installation applications Installation template Installation on walls Installation on wooden or plaster walls Electrical connection Fixing the central vacuum unit to the installation template Removing the central vacuum unit from the installation template Use of the central vacuum unit Starting of the central vacuum unit Use of the central vacuum unit Maintenance Programmed maintenance Replacement of the dust container Replacement of the filter cartridge Cleaning of the filter cartridge Servicing Servicing criteria Spare parts Spare parts list Dismantling General provisions Trouble shooting Trouble shooting mo Io Io 03 07 01 1 GENERAL INFORMATIONS 1 1 Utilising the user guide The user guide is a fundamental document written by the builder to be considered an integral part of the central suction unit We recommend storing and keeping the user guide throughout
6. N Mtr Bi Fen IP Serial number 1 4 Technical Support In case of need exclusively call the Manufacturer Technical Service or an authorized centre always specifying the technical data indicated on the identification plate and the serial number of the central vacuum unit Manufacturer Assistance Service Authorized Assistance Centre Cube 03 07 V01 2 1 5 Safety and security precautions Read carefully any information written in this user guide regarding installation use and maintenance of the central vacuum unit Never use inappropriately the central vacuum unit Never let the children get near the central vacuum unit when it is working and never let the children play with the suction inlets or with the vacuum unit Unplug the central vacuum unit when The power supply cable is worn out or damaged The central vacuum unit has been exposed to the inclemency of the weather or to excessive moisture The central vacuum unit has been damaged by an impact or the external container has been damaged The central vacuum unit requires any repairing or overhauling Always wear protection gloves and mask when carrying out any maintenance operation and when unloading the dust container or replacing cleaning the filter Use only original spare parts Never use the vacuum unit to remove textile stuff big size bits and pieces of any material burning coals or ashes Never vacuum liquids
7. amaged Check the integrity of the flexible hose and accessories and replace them if necessary The filter cartridge is dirty Clean or replace the filter cartridge Top cover damaged or out of place Check the cover integrity and correct placing Dust bag out of place or full Check the correct positioning of the dust bag If full replace it The pipes of the suction system are obstructed Contact the Assistance Service Air exhaust piepes are obstructed Contact the Assistance Service The central vacuum unit keeps running even when the suction inlets are closed The micro switch of a single inlet does not work Turn off the central unit and contact the Assistance Service Cube 03 07 01 18
8. be installed in multi storey buildings the suction unit must be located at the lowest level of the building The central vacuum unit has to be installed in a service room for example in a garage or in a storage room sheltered from atmospheric agents and protected from moisture and temperature changes Chose a space far from heat sources burners or radiators Provide spaces for the unit air flow entry and exit Foresee the air exhausting point outside the house in a position that would not cause damage or nuisance to other buildings 4 3 Installation spaces Leave all around the central unit approx 200 mm each side free and well lit space to allow trouble free maintenance operations repairing dust bag replacement and at the same time allow the air recycling and the motor cooling For any question do not hesitate to contact the Manufacturer Technical Assistance Service 4 4 Installation applications The central vacuum unit is fixed to an installation template that is usually prearranged during the laying of the pipe network It allows the application on walls wooden walls plaster walls The wall on which the template will be installed must have the following characteristics must be solid must be perfectly vertical must not be exposed to vibrations must be perfectly flat or the central unit will result instable 4 5 Installation template The installation template is the central connecting suppo
9. chine remove the flexible hose from the suction inlet The central unit will stop automatically NOTE allow the central vacuum unit a few minutes to stop Cube 03 07 01 12 6 MAINTENANCE ATTENTION ALWAYS UNPLUG THE POWER SUPPLY CABLE FROM THE POWER SUPPLY SOCKET AND ALWAYS WEAR PROTECTION GLOVES AND GOGGLES BEFORE CARRYING OUT ANY TECHNICAL OR MAINTENANCE OPERATION 6 1 Programmed maintenance According to the accumulated operating time of the central vacuum system it is necessary to carry out maintenance operations in order to keep the central unit always well performing and to avoid serious mechanical problems It is suggested to carry out the following maintenance operations Frequency Intervention Carried out by Dust bag full Replacement of the dust bag User Each bag replacement Cleaning of the filetr cartidge User Once a year Check the air exhaust obstruction Assistanzce service The casing of the suction unit needs periodically cleaning Use a smooth and damp cloth with some neutral Soap Attention Be sure to use only water or water with neutral soap Alcohol or other solvents may damage the unit Wait until the unit is perfectly dry prior to start it 6 2 Replacement of the dust bag ATTENTION NEVER USE THE CENTRAL UNIT WITHOUT THE DUST BAG Lift and remove cover gt Cube 03 07 V01 Gently remove the bag from the central unit Place the new bag ATTENTION gently move back and f
10. during central unit installation to foresee upstream the central unit itself a safety bipolar switch The manufacturer declines any responsibility for damages to persons or objects resulting from connecting to an electric system not in compliance with the regulations in force Vdc 12V Micro line Vac 220 240 1 Wire the panel connectors to the wires on the template box Screw drive the panel on the template paying attention to the centring notch 220 240 Suction inlets O Vac 220 240 L N Cube 03 07 V01 10 49 Fixing the central unit to the installation template 00 4 10 Disassembling the central nit from the installation template NOTE This operation must be carried put ONLY in case of real need e g for extraordinary repairing 11 Cube 03 07 01 5 HOW TO USE THE CENTRAL VACUUM UNIT 5 1 Starting the central vacuum unit Put the main switch located on the front of the central unit to the position I ON The led on the switch will light to indicate the central unit is powered on 5 2 Use of the central vacuum unit Fit the appropriate cleaning accessory on the flexible hose Starting To start the machine open a suction inlet 1 Open a suction inlet and insert the flexible hose The vacuum unit starts and the vacuuming begins USO USE USAGE USO BENUTZUNG D Turning off 1 To stop the ma
11. emoved separately and then mixed up in the dust container It is strictly forbidden to use the central suction unit in explosion hazard places or in places where temperature pressure and moisture are out of range Any different use is strictly forbidden The manufacturer must approve by means of written authorization any alteration or modification of the suction unit to remove a specific material Any use different from the original is to be considered improper and health risk for the user and damage to the suction unit cannot be excluded Cube 03 07 01 6 9 3 Basic components Wall template Z3 lt s c Y LE 9 2 ci i 3 Air exhaust Centering pins DNE Electrical box Micro line connections __ gt o o 5 a Ei Centering pins Dust entrance Cover oO xi Q 3 __ supply Air exhaust Micro line connection Main body LLL ON OFF switch Safety Filter EI Safety thermal probe Motor cover f Electronic card Cube 03 07 01 3 4 Technical features Technical features users Max Pogo d 4 4 Surface max m 150 8 Pipes mm 40 1 Power supply Volt ac 220 240
12. he packing material and the accessories placed inside the central unit Dispose of the packing as per the regulations in force Take out all the accessories inside the accessories box Cube 03 07 01 4 2 3 Check of the accessories 1 x a A CG E d 1 x o N 1 x Cube 03 07 V01 3 DESCRIPTION OF THE CENTRAL VACUUM UNIT 3 1 Operating principles The central suction system suitable for any kind of residential building house office hotels service building consists of a of PVC pipes network under the floors inside the walls or the false ceiling spreading in the various rooms and with the suction inlets placed at the end of each sector The central vacuum unit located in utility rooms garages or similar places is connected to the piping network The user starts the central vacuum unit by simply inserting the fitting of the suction hose into the suction pipe inlet 3 2 Allowed and improper use The central vacuum unit has been designed to remove the dust small size solid bits and pieces and dry materials It is forbidden to use the vacuum system to remove textile stuff big size bits and pieces burning and hot materials NEVER vacuum liquids Do not vacuum organic material that may ferment It is strictly forbidden to remove highly explosive materials gun powder or inert materials which can trigger dangerous chemical reactions if r
13. orward the bag so to fit the bag membrane into its slot Reassemble the cover checking that the central body profile is perfectly fitted into the cover indent Cube 03 07 V01 6 3 Replacement of the filter cartidge ATTENZIONE NEVER USE THE CENTRAL UNIT WITHOUT THE FILTER CARTIDGE Lift and remove cover see previous paragraph Remove dust bag see previous paragraph Lift the filter cartridge from its seat gt 4 Reassemble dust bag and cover 15 Cube 03 07 V01 6 4 Cleaning the filter cartridge ATTENTION NEVER USE THE VACUUM UNIT WITHOUT THE FILTER CARTRIDGE BEFORE CARRYING OUT THE OPERATION DESCRIBED HEREUNDER ALWAYS ASSEMBLE A NEW CARTRIDGE The filter cartridge can be washed with gt water ATTENTION before reassembling the filter make sure that it is completely N dry Check if the surface of the cartridge is torn in this case the filter cartridge cannot be used any longer Cube 03 07 V01 16 7 SERVICING 7 1 Servicing criteria It is strictly forbidden to operate on the central suction unit to carry out any maintenance or servicing not mentioned and therefore not allowed in the user manual Only qualified providers of the technical assistance service can carry out any maintenance or repair operations The guarantee will not apply in case of interventions carried out by non authorized staff and the manufacturer cannot be considered responsible for possible injurie
14. rt to the wall It usually prearranged during the laying of the pipe network The installation template is connected to the vacuum and exhausting pipe network and NG electrical connections to the micro line and to the power supply line NOTE In case the template and the pipe network are already installed verify the electric box installation If also the electric box is already installed go to the section Fixing of the central unit to the installation template In case the template has yet to be installed carefully read the two following points Accordingly to the kind of wall on which it will be installed carefully follow the instructions hereafter 4 6 Installation on walls See illustrating sheet annexed to the instruction manual 4 7 Installation on plaster or wooden walls See illustrating sheet annexed to the instruction manual 9 Cube 03 07 01 48 Electrical connection IMPORTANT BEFORE CARRYING OUT ANY CONNECTION TURN OFF MAIN POWER SUPPLY ATTENTION INSTALLATION MUST BE CARRIED OUT EXCLUSIVELY BY QUALIFIED STAFF Before connecting to the power supply verify that voltage corresponds to the one required by the central vacuum unit Power supply line must have cables with section diameter not less than 1 5 mm Do not connect the machine to a power line with excessive tension rush ideal tension local voltage 10 Power the low voltage inlet signal with safe very low tension It is suggested
15. s to persons and damages to things resulting from this kind of intervention 8 RECOMMENDED SPARE PARTS 8 1 Spare parts list It is advisable to stock the spare parts more subject to wear In order to guarantee the best performance of the central vacuum system we suggest using only original spare parts Please find below a list of spare parts Description Quantity Spare Part Code Filter cartridge 1 See commercial brochure Dust bag Packing See commercial 10 Pieces brochure 9 DISMANTLING 9 1 General instructions When dismantling the central suction system dispose appropriately of used parts or material which could endanger human health or well being as well as the environment if handled improperly You must be acquainted with sites companies authorized to collect and dispose of used parts and materials The disposal and or recycling of any part of the suction system must be carried out in compliance with the legal regulations in force Disposal of Old Electrical amp Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This symbol on the product or on its packaging indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment reduce the environmental impact of WEEE Waste electrical and Electronic Equipment and

Download Pdf Manuals

image

Related Search

Related Contents

Système de stockage distribué à faible coût  Sanyo UR18650V User's Manual  Philips FR999/17 User's Manual  SERVICE MANUAL - 北京天勤安捷技术发展有限公司  Boss Audio Systems Chaos Exxstreme  QUICK START GUIDE - Timex.com assets  manual de utilização do prototyping board manager  Philips AT895/41 Data Sheet  Toshiba 32HL834 LED TV  ビアフ  