1. AND ACCESSORIES Pi On iN on 8 Cut bands and slide the complete carton off the pallet Remove the top of the carton and packing pads from top of Koo Kare DiagnosTech system Slide large box off the KoolKare DiagnosTech system Remove packaging material from all sides of the Koo Kare DiagnosTech system Remove the plastic wrap from the KoolKare DiagnosTech system Remove accessory box from rear of the Koo Kare DiagnosTech system and set aside Break the back side of the lower carton to allow the KoolKare DiagnosTech system to roll out Carefully slide the KoolKare DiagnosTech system off the lower carton Tipping the Koo Kare DiagnosTech system on the back wheels will assist in removing from lower carton Remove shipping pad from underneath the KoolKare DiagnosTech system PARTS amp ACCESSORIES SETUP w on oon gt INSTA Remove all parts and accessories from box Verify against list above Locate the 2 Boom assemblies EAA0248L50A amp EAA0248L51A Locate the screws 4 Mount the 2 Boom assemblies to the back of the Koo Kare DiagnosTech system using the supplied screws Locate the Blue Pod Hose Assembly EAA0248L07A Remove the packing material Drape the Pod Hose Assembly over the boom for storage Locate the Red Pod Hose Assembly EAA0248L06A Remove the packing material Drape the Pod Hose Assembly over the boom for storage Locate the 2 Temperature Probes 2 7642 15 amp 2 7742 25 Connect t
2. EEAC315A KoolKare DiagnosTech System 1of3 Installation Instructions INSTALLATION MUST BE PERFORMED BY QUALIFIED PERSONNEL ONLY INSTALLATION OVERVIEW The Installation Procedures listed is for the KoolKare DiagnosTech system The unit is shipped as a fully assembled unit with the exception of the items listed in the Parts amp Accessories List PLEASE READ THESE INSTRUCTIONS COMPLETELY BEFORE SETTING UP UNIT A CAUTION THIS UNIT MUST BE PLUGGED INTO A PROPER AC OUTLET FOR UNIT TO OPERATE CORRECTLY REFER TO THE UNIT ID PLATE LOCATED ON BACK OF UNIT EXTENSION CORDS ARE NOT RECOMMENDED BUT IF AN EXTENSION CORD MUST BE USED USE A CORD THAT IS LESS THAN 50 FEET WITH A 14 AWG OR ABOVE 50 FEET AND LESS THAN 100 FEET WITH A 12 AWG A WARNING USE STANDARD REFRIGERANT HANDLING SAFETY PROCEDURES WHEN PERFORMING INSTALLATION ALWAYS WEAR SAFETY GOGGLES DON T SPILL OR TOUCH LIQUID REFRIGERANT AVOID FLAMES AND EXCESSIVE HEAT USE ONLY IN WELL VENTILATED AREA TEEAC315A0 06 30 2000 REV A Page 2 of 3 PARTS amp ACCESSORIES PART NUMBER DESCRIPTION QTY 1 2405 Screw 4 1 15080 Low Side Adapter Fitting 1 1 6181 Filter Conical 2 2 7642 Temperature Probe 15 1 2 7742 Temperature Probe 25 1 EAK0027CO00AS O Ring Kit for Service Couplers 1 EAA0248L50A Boom Hanger High Side 1 EAA0248L51A Boom Hanger Low Side 1 TEEAC315A0 Installation Instructions 1 ZEEAC315A User s Manual 1 UNPACKING UNIT
3. he 2 7642 to the Temp 1 and the 2 7742 to Temp 2 near the top left side of the rear of Koo Kare DiagnosTech system LLING VIRGIN TANK Locate a new R 134a Virgin Tank Connect the yellow tank hose located in the back of the KoolKare DiagnosTech system from underneath the cabinet to the R 134a Virgin Tank Turn tank upside down and set on top of the virgin tank holder Secure using the Velcro strap Turn virgin tank valve on TEEAC315A0 06 30 2000 REV A Page 3 of 3 INITIAL STARTUP SEQUENCE i a fF oO DN Plug the KoolKare DiagnosTech system into a standard 115Volt AC outlet Turn the KoolKare DiagnosTech system on using the front panel power switch Wait for the 1 minute warm up to complete Press the NEXT button to go to the next menu Press the SETUP button Press the Elevation button to set the elevation level and to calibrate the internal transducers Follow the screen instructions for proper procedure Press the Time Date to adjust if incorrect Press CANCEL bution to return to the main menu Wait 5 minutes and the KoolKare DiagnosTech system will automatically fill the internal recovery tank to 15 pounds You may elect to perform the manual fill by selecting NEXT on the main menu then select OPTIONS INSTALLATION COMPLETE SETUP COMPLETE FINAL REVIEW Review the User s Manual for full operation of the KoolKare DiagnosTech system Fill out the warranty registration form and mail back to EquiServ O
4. r go online at www EquiServ com and fill out the online warranty registration form Be sure to turn off the R 134a Virgin tank when not in use After reviewing the User s Manual place it in the holder on front of unit for future use For Technical Support please call EquiServ at 1 800 225 5786 REPLACEMENT PARTS High Side Service Coupler 1 27180 Low Side Adapter Fitting 1 15080 Low Side Service Coupler 1 27280 Master Filter Dryer 1 9881 Printer Ink Cartridge 2 20466 Paper Roll 5 8126 Refrigerant Identifier Filter EEAC300A1 Service Coupler O Ring Kit EAK0027CO0AS TEEAC315A0 06 30 2000 REV A

Download Pdf Manuals

image

Related Search

Related Contents

Aides d`Etat et services sociaux  Sanyo PLV-HD10 User's Manual  PM4C-05A Manual  Instalação electrostática de revestimento de cabos ECC 701  Moxa AWK-3131 User Manual  De Dietrich DFF1310J freezer  Massive Wall light 17102/47/10  Paradyne 8620 Security Camera User Manual  Cub Cadet 221 HP Snow Blower User Manual  CosmoAIR Klimageräte Split  

Copyright © All rights reserved.
Failed to retrieve file