Home
pobierz
Contents
1. transmitters or metal screening may cause interference and reduce operation range l l Receiver s wire antenna should be let loose downwards and not glued to wall Jumpers placed next to output relays on the receiver s pc board are used for selecting standby mode NC normally closed or NO normally opened 8 2 1 S Table operating modes of output S ae JP2 shorted JP2 opened JP1 shorted Two pulses on any output set on one pulse Shorting to ground at low battery warning rar 5 3 2 3 ot output set ott Radio link failure signaling if JP3 also opened t ae 7 JP1 opened Pulses on channel 1 set on off only g j p fo Sp PROGRAMMING PROCEDURES aT tf Programming is made with housing s front panel taken off and the use of PRG switch on the receiver s board 1 Learning transmitter s to receiver s memory maximum 40 a Press receiver s PRG switch for less than 2 seconds The receiver s central LED switches to red and the first Receiver s board channel set on LED illuminates b Shortly pressing the PRG switch select the required channel for programming transmitter to c Press the PRG switch until the receiver s LED switches to green d Depending on type of programmed transmitter proceed as follows for hand transmitters double press the transmitter s switch For multi channel transmitters press switch number respectively to number of channels to program example double pressing the 3 swit
2. EIGHT CHANNELS DYNAMIC CODE RECEIVER CH8Hhet EN This microprocessor controlled eight channels receiver is designed to operate with large number of transmitters in wireless alarms and access control systems using KEELOQ dynamic signal coding offering highest level of security The receiver features eight galvanic separated NO NC relay outputs with front panel LED channel indication and signal control output S It operates with all Elmes Electronic made 433 92MHz band wireless detectors and transmitters including RP501 and features warning signals of radio link failure cabinet opening or tamper and low battery state in learned transmitters Each channel may have learned any number of transmitters with total number not exceeding 40 Learning next transmitter would delete first in memory The need to delete one transmitter requires deleting all in receiver s memory and learning remaining transmitters again The CH8H receiver offers range of applications including wireless detector s interface to any wired control panel monitoring alarm signals from Elmes wireless transmitters such as CTX GBX PTX and RP501 and UMB100H hand transmitter programmed to channel one arming and disarming the system calling and wireless panic button with users having hand transmitters e g AN200H or UMB100H as personal panic button alarm triggers In calling system the use of hand transmitter would set on a call lasting for earlier programmed time period Two channel han
3. as from date of purchase The warranty is limited to the replacement of faulty original parts or repair defects of improper manufacture Damage faulty use or improper handling by the user or installer as well as any changes in product s hardware or software caused by the user or any other unauthorized person violets the warranty and all due repair costs will be charged Elmes Electronic shall not bear any liability for any personal or material damage resulting from its any product direct indirect or partial failure to operate properly KEELOQ is a registered trade mark of Microchip Technology Inc USA ELMES ELECTRONIC phone 4871 7845961 fax 7845963 e mail elmes elmes pl_ www elmes pl Elmes Electronic 03 2007 All rights reserved C Elmes Electronic declares that the product has been manufactured and tested to comply to the following standards
4. ch in four ch transmitter CH4H will program first three channels The fourth channel will not be active in this receiver for the PTX50 detector set the detector internal transmission channel selector to 1 and activate two transmissions by moving hand in front of the detector for the CTX3H CTX4H wireless contacts activate double transmission by double quickly moving magnet in and out of the CTX housing for the RP501 transmitter operation with radio link testing is not allowed set the required mode of operation and activate transmission by opening any of its four inputs respectively to number of channels required example activating input 2 will program input 1 and 2 while 3 and 4 will not be programmed e Slowly blinking LED in the receiver will indicate end of the procedure 2 Setting the outputs set on time in selected channel a Press receiver s PRG switch for more than 2 and less than 8 seconds LED switches to red and next to green The first channel LED illuminates b Pressing the PRG switch select illuminating LED indicates selected ch required channel for programming its output momentary set on time c Press the PRG switch for longer than 2s till the receiver s LED switches to red d Shortly press PRG switch and the LED switches to green counting of set on time is started When desired set on time has lapsed up to 4 hours press the PRG switch again The LED lights red and after next 2s blinking receiver s LED ind
5. d transmitters e g DW200H or DWB100H used as wireless panic buttons may have one button used for quiet alarm function while the other used for a loud panic alarm OPERATION Activating transmitter programmed to CH8H receiver sets on respective channel relay output and illuminates the channel s LED Depending on programmed operation mode see programming procedures p 2 the receiver s relay outputs are set on amp off in one of two following modes 1 Momentary pulse mode lasting from 0 5 second up to 4 hours 2 Latching on off mode setting relay output on and off by consecutive signals received from transmitter Output S generates two pulses on any channel relay set and one pulse on reset Also it signals low battery and radio link failure warnings according to settings made with jumpers JP1 JP2 amp JP3 see table below Multichannel transmitters and RP501 transmitter always set on off adjacent relay outputs Elmes PTX GBX and CTX wireless detectors signal alarms in two channels motion detection in any of the eight channels and tamper alarm in channel eight automatically assigned at learning the detector to receiver procedure The channel number eight signals also receiver s power cut off cabinet opening and wiring cut off Operating with RP501 transmitter in radio relay mode or with CTX3H and CTX4H detectors operating in open close monitoring mode the receiver s outputs state correspond to the transmitter s inputs meaning that t
6. he outputs are set on for as long as the transmitter s inputs are opened In case of CTX4H for as long as the magnet stays away The receiver monitors battery state in Elmes transmitters type PTX50 GBX CTX and RP Detected low battery in one of the transmitters is signaled by blinking of the front panel main LED and if the JP2 is opened see table by output S shorted to receiver s ground The number of LED pulses in a series correspond to channel number with low battery detected The signaling sets off automatically after battery is replaced and transmission activated Identically the CH8H receiver signals failure of radio link in operation with transmitters PTX GBX and CTX4H CTX4H serial number gt 610000 The transmitters send identification signal every 10 hours If any signal is not received by receiver within 24 hours time period e g for reason of its failure this will be warned by blinking receiver s main LED and if JP2 is opened output S shorted to ground To activate this function jumper JP3 should be set open INSTALLATION amp OUTPUTS SETTING CH8H wiring diagram Receiver CH8H is designed for indoor operation only within temperature range of 0 to 40 C Operating range Relay s outputs Buzzer with wireless detectors and transmitters highly depends on place of installation High humidity electromagnetic A he eee lt power lines nearby radio
7. icates end of the procedure NOTE To program latching on off output mode of selected channel press the PRG switch three times at subcl 2d with less than 2s intervals 3 Deleting all transmitters from the receiver s memory Press receiver s PRG switch for more than 8 seconds the receiver s LED switches to red and next to green until the receiver LED starts blinking and then release the switch Memory of the receiver is cleared but the channels programmed modes of operation remain unchanged To learn new transmitter s to the receiver s memory follow procedure above Note programming errors are indicated by fast blinking LED The receiver sets off programming mode automatically if activity is not detected within 30 seconds SPECIFICATION eight channels with NO NC galvanic isolated relay outputs rating 1A 24VDC or 0 5A 125VAC and LED indication in each channel superheterodyne 433 92MHz band receiver with front panel LED indication output S for external siren 40 hopping code transmitters memory power supply 11 to 1SVDC nominal 12VDC with 180mA max current on all relay outputs set on relay output EN 60950 1 2001 electric safety EN 301 489 1 V1 4 1 2002 08 EMC for radio equipment EN 301 489 3 V1 2 1 2002 08 EMC for Short Range Devices EN 300 220 3 V1 1 1 2000 09 EMC and Radio Spectrum Matters Manufacturer s limited warranty Elmes Electronic products carry manufacturer s one year limited warranty
Download Pdf Manuals
Related Search
pobierz pobierz chrome pobierz pobierz upo pobierz krs pobierz z yt pobierz google pobierz windows 11 pobierz mp3 pobierz windows 10 pobierz program symfonia pobierz z youtube pobierz muzyke pobierz symfonia pobierz film z yt pobierz mp3 z yt pobierz firefox pobierz brave pobierz z youtube mp3 pobierzgrepc pobierz film pobierz opera gx pobierz netflix pobierz mozilla pobierz sklep play pobierz film z youtube