1. B2000 received enough length data from COM port KB2000 will transmit the data to the network KB2000 will transmit the data to network when it satisfies Max MEM Time and Max MEM Bytes in one of two conditions 3 5 Configuration DTU Parameters Firstly user is advised to connect KB2000 C with the same subnet through network cable by Switch or HUB and power on it User can set KB2000 C User can Manage KB2000 C with the program NetConvertor exe NetConvertor can manage all KB2000 C in current subnet It can search KB2000 C view KB2000 C parameters set KB2000 C and so on The interface of the program as follow E al xi mr KBZ000 Data Convertor 1 13 ABO MEH Boe AEH 2 m rr X EE E E ate E SET TEL T perse da iE th SEHR EH RSS I IP E Search KB2000 User can find all KB2000 C through Search in the subnet Please chose File menu then Search Or you can click Search button on the toolbar View parameters Please double click the icon of KB2000 C that searched or after you searched KB2000 C you can click Parameters button on the toolbar Just as below picture KingBird CT Shenzhen Kingbird Network Technology CO LTD KB3030 N GPRS DTU Parameters Setting IF 192 168 1 9 MAC Do 08 3C 01 0E E4 FWD fo General i Het COM Scott amp Type P sl ID Target III Zone valid n Bi Lone HU noni Heartbeat Efa Click Read button in this dialog read the parameters again S
2. KingBird 4 Shenzhen Kingbird Network Technology CO LTD KB3030 N GPRS DTU KB2000 C Web photograph Terminal User Manual Shenzhen Kingbird Network Technology CO LTD Add 12C 12D Tower B Haiwang Building NanHai Road Nanshan District Shenzhen Guangdong China TEL 86 755 82556825 83239613 Fax 86 755 83239613 EXT 8012 Web hittp www kingbirdnet com EMAIL sales kingbirdnet com KingBird eT Shenzhen Kingbird Network Technology CO LTD KB3030 N GPRS DTU 1 System overview Thanks for you to use our products KB2000 C is one of our new developed Web photograph terminal based on our KB2000 KB2000 C can send the photo back to server through the internet user connect to the web server on the internet through the mobile or computer then control the camera and check the photos Mean while KB2000 C also can connect with infrared sensor and Trigger photograph Due to the data communication is used the B S architecture this let the manage of the whole system no limited with time and region can manage it by the terminal connected with the internet any time 2 Camera technical parameters and performance characteristics Resolution 640x480 Output format JPEG Minimum illumination 1 lux WB automatic Lens 6MM IR Exposure automatic Visual angle 60 degree Night vision open illumination 5Lux Figure night vision image black and white Night vision distance 3 5 meters Environment conditions Outdoor monitoring Output R
3. S232 Baud rate 115200bps oize 125mm long 60mm diameter Working environment 30 C 80 C Humidity 20 80 Work voltage DC 5V 2A 3 Interface and installation 3 1 LED Indicator light KB2000 C has two LED Indicator light LED1 Network Double color Often bright red means network link OK green flicker means data from net LED2 Com Double color red flicker means data transmitting from COM green flicker 2 KingBird A 8 Shenzhen Kingbird Network Technology CO LTD KB3030 N GPRS DTU means data to COM 3 2 Network interface RJ45 KB2000 C connect with network 3 3 Camera an power interface KB2000 C use green 10pin interface detailed definition as follow From left to right UTXD1 A URXD1 B Output 1 Input 1 Output 2 IR DATA KB2000 C Interface detailed definition vec PowrDON OOOO o 2 enn eom Output NO 1 oO BEEN Ground COM 8 Oum Output No 2 of 10 i 9 Status On line is high level off line or signal weak is low level 3 4 Parameter Specification Name Named current KB2000 C the Max length is 16bytes ASCII code a ni Shenzhen Kingbird Network Technology CO LTD KB3030 N GPRS DTU Password When you set the parameters of KB2000 C you must input password password is 6bytes ASCII code Type Include A and B two types Type A is mainly used in Main station Type B is mainly used in slave station ID Current KB2000 C s ID Target ID If the type of KB2000 C is type A this ite
4. e platform Trough the web account and pass word user can log in the manage platform log in succeed will like below picture 20134F4 9H 12 02 21 ROMP Hop RE sei Gilet p RS 1 mA K on pamm Cip Xd BRAS WEFR 1013 2 1 17 00 18 PRAH 12 6 2 Check the Teminal Click the user product go to the user and user s product checking page as below picture KingBird a Ghenzhen Kingbird Network Technology CO LTD KB3030 N GPRS DTU 2013464 H9 H 12 08 04 RPA gate am wie gare a mg orso P emm an 1 00000006 tong tee Su Omie weak Mee O ea 2 6000000006100 tong lee rl Offime Wo NT o ga x 3 00000007222 tonglee T Offine IMR Ol gamma 4 00000007225 ongying Offine SIB aus o 5 00000009761 ingie EE Diu ee Me o 6 00000009759 dongying La Offpe Mek Ol 7 60000002000 tonglee EI Of ne Miki O a 6000000200 tongiee ETT Of xia O rea HASH 15mm mi FH vA 6 3 Check photos Click the photo checking check the pictures like below picture ul anm oun nl eege 0013224 epresd 8E act Alfa 2013 1 25 17 400 Biet 2013 1 25 1734 290 AHA 2013 1 25 17 4400 7 RA Ge FT ED FOS MA rim BM E N
5. et KB2000 C If you want to amend parameters of KB2000 C you can set them in the parameters setting dialog Chose a KB2000 C in the list then click parameters button in the toolbar you will go to the parameters setting dialog the interface as follow T Shenzhen Kingbird Network Technology CO LTD KB3030 N GPRS DTU IF E 16 1 9 MAC o0 08 30 01 0E E4 PUT ton IP ise 1681 9 Lat ew av HERE Mask 255 255 255 0 fret IP from automatice T Frotacal TLF m Target IF rte Target TCP por dece Target UDP por thier Parameters Setting IF E 16 1 9 MAC o0 08 3C 01 0E E4 FHI e General Net 9 Baud rate 36400 Data bits Verify Stop bits Max Mem time pn MS Max Mem bytes 720 Bytes If you need to amend some parameters Please click Set button after amendment then the parameters will be set Note 1 When you set KB2000 you must input password the default password is 000000 2 If you forget your password please connect the PE pin to the GND pin when you set parameters thus the password can not be required 3 Some parameters must not be changed the software have forbid them 4 If you want to use IO function please ask for IO control protocol from our company KingBird Lee a Shenzhen Kingbird Network Technology CO LTD KB3030 N GPRS DTU 4 Safe Use After the correct configuration and installation user can mange KB2000 C terminal by the Web platform 6 1 Log in the mang
6. m just is used When type A wants to communicate with type B this item value is set to the ID of type B Zone valid If you want to use Zone you must set it to ON Zone The current KB2000 C s Zone number of the Network if type A wants to communicate with a quantity of type B you must set type A and type B the same Zone number and the Zone valid all be set ON Heart beat The interval of KB2000 connection or communicate with remote server IP IP address of KB2000 when it join into one subnet its IP must be distributed depend on the network section Gateway The gateway of subnet which KB2000 accessed Subnet Mask It depends on the subnet Get IP from The type of getting IP include Manually and Automatic In Manually IP address can be set KB2000 will use the IP address which user set If in Automatic KB2000 can get the IP address by DHCP protocol DHCP server must be in the subnet if you can not get IP through automatic please use manually Protocol Network protocol support UDP and TCP Target IP KB2000 is client side working way it must have server IP The default value is Kingbird s if user don t have server can use Kingbird s server for free if quantity is less or hire Kingbird s server if quantity is more then this value no need to reset Target TCP port The TCP port for specified KB2000 communicate with Target Main machine The default value is the TCP port of Kingbird s if user don t have server can use Kingbird
7. s server for free if quantity is less or hire Kingbird s server if quantity is more then this value no need to reset Target UDP port The UDP port for specified KB2000 communicate with Target Main machine The default value is the UDP port of Kingbird s if user don t have server can use Kingbird s server for free if quantity is less or hire Kingbird s server if quantity is more then this value no need to reset Baud rate The data transmit speed User must set it same as PC or terminal device which connected The bard rate of KB2000 support from 300pbs to 115200pbs Data bits In COM port asynchronous transmission a group data real include data digit KB2000 support 5 8Bits data bits Data bits must be set the same as the PC or terminal device which connected In general it is 8bits Verify KB2000 s COM verify have three types None Even Odd User must set it same as PC or terminal device which connected Stop bits In COM port asynchronous transmission a data digit to indicate the end of this group data KB2000 support one and two stop bits User must set it same as PC or terminal device which connected In general the stop bits is 1bit Max MEM Time When KB2000 received data from COM port it will go into the buffer if over Max MEM Time and there are not next data come in KB2000 will transmit the data to 4 KingBird Ech Shenzhen Kingbird Network Technology CO LTD KB3030 N GPRS DTU the network Max MEM Bytes When K