1. whenever alarm conditions occur For example if you have Box NI2R digital analog inputs as fire gas human activity or other sensors you can configure Box N12R to send you sms whenever the alarm conditions occur Alarms are separately available for analog and digital inputs a Alarms for digital inputs When you are setting up alarms for digital inputs you would need to configure the following 7 parameters Parameter Description Possible values It s the name of alarm and does Text numbers special Name of the not have any effect on operation of characters alarm alarm It s just for easy identification in case you have more than one alarm This is the text message the Text and numbers Alarm message authorized users will receive via sms User manual Teltonika Alarm and Control Configurator User manual if any alarm occurs If Trigger state is selected Either 0 or 1 Galas HIGH then the Value should be 0 and if Trigger state is selected LOW then the Value should be 1 Choose the input which has to be Choice from the pull down monitored for alarm condition menu Digital or Analog Since the Input configuration is being explained for digital inputs select digital from pull down option Selects the level change Choice from the pull down direction which would trigger the menu Trigger alarm For example if you select high or low me
2. 4 7 Load TACC gives you the possibility to load previously stored configuration settings The configuration settings can be loaded either from a previously saved configuration file or directly from Box N12R The configuration settings loading procedure is very similar to the saving procedure To load the configuration settings click on the load icon 1 the choice menu appears displaying Box N12R and File options If you are unable to see your module click the Refresh button Select Box N12R or the File and click OK If you are loading the configuration settings from the module the settings would be directly loaded once you click OK However if you are loading the configuration settings from a File you will have to browse to the file location of previously saved configuration file Note Please note that the configuration settings file can only be loaded if you had previously saved it to Box N12R or File Teltonika Alarm and Control Configurator User manual version 2 0beta Alarm amp Control Configurator QETELTONIKA h inputs Input Input changeto Timeout ms Recipient ACK sms AINI ji 0 Administrator 0 Employee 2 3000 Group 2 0 Employee 1 0 Administrator Refresh DK Add Alarm Delete Alarm Figure 6 Load menu 4 8 Restart Restart button will allow you to restart the BoxN12R connected to your PC When you click Restart a window will p
3. for the first time please follow the mentioned steps for a trouble free configuration a Create user users b Create a group if required c Create alarms box n12r actions d Configure for remote commands Save the configuration to file box n12r f Restart box n12r Teltonika Alarm and Control Configurator User manual 4 Configuration Menus 4 1 User User configuration allows you to enter the details of authorized persons The users entered here would have the privileges to receive alarm alerts or control the actions of Box N12R through sms call In order to set up the users you should press the User s icon 1 on the right side of the TACC refer figure 1 Alarm amp Control Configurator amp rerronmal User Mobile Phone 37098745612 3701 5678 1 37056324789 37922222222 4 country_code mobile phone Figure 1 User menu Press the Add User button 2 to add new user then double click on the line to enter user name 3 and telephone number 4 When you want to delete any user select the respective user users and press Delete Users Note Whenever a user is deleted he will be removed from corresponding groups alarms remote commands to which he belonged However if the groups alarms remote commands belonged only to a single user deletion of this user would also result in deletion of corresponding groups alarms remote commands 4 2 Configuration of the user groups If you have multiple us
4. have the right to execute the commands This can be done by clicking under the column Member s and clicking on the name of desired member group The last step is to decide the actions which would be triggered when the remote command arrives The actions can be selected by clicking under the column Action s 4 Upon clicking a window Add Box N12R action will pop up This window displays the actions which are available to add Select the required actions 5 and press Add 6 You are free to Teltonika Alarm and Control Configurator User manual add as many actions which are available If you want to remove any action select it from Selected box and press Remove This completes the configuration of remote command a Remote command through sms If you had configured the remote command by selecting sms in the Type of command column then you can send the sms and trigger the corresponding actions The sms would only be accepted from members selected under Member s column The text of the sms should exactly contain the command as described in Name of the command b Remote command through call If you had configured the remote command by selecting call in the Type of command column then you can just call the SIM number of Box N12R When the Box N12R receives the call it will drop the call and trigger the corresponding actions 4 6 Save Once you have set alarms remote com
5. HIGH alarm will be triggered when corresponding input goes high The time interval after which the Time in seconds Any interval en alarm will be sent to the recipient if you need the alarm conditions still exist Noise cancellation Choose the users or groups of Choice from the pull down Recipient users who would receive the alarm menu users and groups you setup before Alarm Message which would be sent Text and numbers release sms when alarm condition is gone Teltonika Alarm and Control Configurator User manual version 2 0 1 Alarm amp Control Configurator 1 SETELTONIKA Hysteresis Value Input Trigger state Timeout ms Recipient Alarm release sms 2200 AINI high Administrator Fire extinguished 1 DING low Employee 1 Garden watered 0 2400 AINZ low Administrator Gas leakage stopped 00 Group 2 Temperature normal Water level High water level 0 DIN high 0 0 DING high 0 3 0 Employee 2 Water level normal 3 Double click and configure settings of alarms Add Alarm Delete Alarm mm Figure 3 Alarms menu b Alarms for analog inputs When you are setting up alarms for analog inputs you would need to configure the following 10 parameters the 3 additional parameters are shown in bold Parameter Description Possible values Name of the alarm It s the name of alarm and does not hav
6. RETELTONIKA E TACC Add Alarm Delete Alarm j Teltonika Alarm amp Control Configurator TACC Version 2 0 1 User manual Teltonika Alarm and Control Configurator User manual Legal notice All rights reserved Reproduction transfer distribution or storage of part or all of the contents in this document in any form without the prior written permission of Teltonika is prohibited Other product and company names mentioned herein may be trademarks or trade names of their respective owners Copyright 2006 UAB Teltonika Disclaimer The use of Teltonika Alarm and Control Configurator or Box N12R is at sole discretion of the user Teltonika cannot be held responsible for any damages arising due to use of Teltonika Alarm and Control Configurator or Box NI2R Therefore any liability claims would be discarded Teltonika Alarm and Control Configurator User manual Contents 1 Dilraduction ira ee 4 PD AUR E RRBERERE N ITIAREEER A DEREK Stace en E A 4 3 Confis rati n SEID ee re Renee 5 4 ol 2 rallon Mens ae aiie 6 4 MUSEE Siis csie RUREEHEA FREIEREDETURE UEREDBFREUNGEHE E a a R aa aas 6 4 2 Configuration of the user See 6 L Alis eee ee E a a e E E merry 7 a Alarms Tor digital Inpuls u uneselene vesncgacssautdadssanacardasmonadas 7 b Alarms Tor analog TUS nen ee 9 2 4 Box NI2R ACUI nen eek 10 4 5 Remote command een een 12 a Remote command through sms ee ee 13 b Remote command through A
7. e any effect on operation of alarm It s just for easy identification in case you have more than one alarm Text numbers special characters Alarm message This is the text message the authorized users will receive via sms if any alarm occurs Text and numbers The width of the deviance where Numerical Hysteresis the alarm will not occur noise cancellation for analog signal Please refer to the note at the end Numerical in mV Value of this table maximum acceptable value is 2500mV Choose the input which has to be Choice from the pull down Input monitored for alarm condition menu Digital or Analog Since the configuration is being Teltonika Alarm and Control Configurator User manual explained for digital select digital from pull down option Selects the level change direction Choice from the pull down which would trigger the alarm For menu high or low Trigger state example if you select HIGH alarm will be triggered when corresponding input goes high The time interval after which the Time in seconds Any a alarm will be send to recipient if the interval you need alarm conditions still exist Noise cancellation Choose the users or groups of Choice from the pull down Recipient users who would receive the alarm menu all the users and groups you setup before Alarm release Message which would be sent Text and numbers sms when alarm conditio
8. ers and you want to manage classify them you have the possibility of creating groups Only the users defined in Users menu can be added in the groups To start creating groups click the Groups icon 1 Click the Add Group 2 button to add new group then double click on the line 3 to enter the name of the group To add members to this group double click same line 4 under the column Members of group A dialog box will pop up showing the users which can be added refer fig 2 Select the users 5 and click Add 6 To remove any member from the group click on the members a dialog box will pop up Select the user to be removed from the right Teltonika Alarm and Control Configurator column and click Remove If you want to delete the entire group select the corresponding group and press Delete group version 2 0beta Alarm amp Control Configurator GETELTANIKA Qada cr lete Gro N roup Delete up Figure 2 Groups menu Note Authorized group is the default group and should not be renamed If this group will be renamed you won t be able to create new groups Deletion of the group will result in deletion of all the alarms remote commands which solely belonged to this group 4 3 Alarms One of the main functions of TACC is to alert you whenever digital analog inputs to the Box NI2R cross their predefined value You may setup the alarms in order to receive sms
9. ll 13 A O SIVE neenetsi aaa E a A a E E E a e NE 13 4 il nenne 14 5 portant THES een 15 Teltonika Alarm and Control Configurator User manual 1 Introduction Teltonika Alarm and Control Configurator TACC is software which has been specially designed for Teltonika Box N12R The software allows easy configuration of alarms and control of Box N12R from remote location through sms or call The software has a simplified and user friendly interface TACC forms a part of our M2M products 2 Features e Simple user friendly and intuitively perspicuous interface e Create alarms for analog or digital inputs e More than 10 users can subscribe for one input alarm e Simple user and group management e Availability to save settings as a parameter file to the PC to use them later for other modules or as backup e Control multiple outputs by sending a single command through sms e Trigger various outputs in desired sequence and desired intervals e Create authorized users and groups e Possibility to edit change and save configuration of Box N12R directly version 2 0 1 Alarm amp Control Configurator QO TELTONIKA Alarm name Alarm sms txt Hysteresis Value Input Trigger state Timeout ms Recipient Alarm release sms Add Alarm Delete Alarm Teltonika Alarm and Control Configurator User manual 3 Configuration setup 1 Unplug the power supply 2 Insert the SIM card in Box N12R it is recommended to remove the PIN code
10. mands actions and such other parameters you can save the settings in a file on your PC or directly to Box N12R In order to save the settings you should press on the USB pen drive icon 1 of the program refer figure 6 A window will pop up and display the connected devices and file option If you don t see your connected device click Refresh Near the File and the Module could be 3 different pictograms refer figure Select the file option to save the file on PC If you want to save the settings directly to Box N12R select the corresponding Box N12R from the list and click OK Once you save the configuration settings directly to Box N12R it will restart automatically Possible pictograms Icon Description When there is no SIM card inserted sometimes reboot is required to see newly inserted SIM EN When the SIM card is PIN code protected to enter it just double click on icon W SIMis OK Teltonika Alarm and Control Configurator User manual E Tace version 2 0beta Alarm amp Control Configurator QETELTONIKA Save to File Box N12R with IMEI 352540003016424 b inputs Input Input change to Timeout ms Recipient ACK sms AINI high 0 Administrator high 0 Employee 2 low 3000 Group 2 low 0 Employee 1 high 0 Administrator a Select file or module Refresh J g Add Alarm Delete Alarm Figure 6 Save menu
11. n is gone Note Box NI2R can accept analog signals in the range of 0 10V However the input voltage is scaled down by 4 Thus 0 10V output of your sensor would correspond to 0 2 5V So for example if you want to trigger the alarm at 6 volts you should divide it by 4 and enter this value in Value column 4 4 Box N12R actions Box N12R actions is a newly added feature to TAC As its name says this feature will allow you to configure the actions of the outputs of Tbox However these actions can only be triggered by Remote commands Therefore it is necessary to configure the Box N12R actions before configuring Remote commands Teltonika Alarm and Control Configurator User manual version 2 0 1 Alarm amp Control Configurator i QETELTONIKA Box N12R actions E Name Output Status upheld ms Close gas valve DOUTS 0 OFF Turn ON Fire extinguisher 0 ON Turn ON heater S00 ION Valve 200 TOGGLE 3 Double click and configure a Figure 4 Box NI2R actions menu Click on Box N12R actions 1 and then click on Add action 2 a blank row will appear Double click 3 under the column Name of action and enter the name The name of action does not have any role in execution of the action It s just used as identification so you are free to give any independent name In the next column Output you can select the output which you wish to c
12. ontrol The outputs can be selected by clicking under Output column and selecting the desired output from drop down selection box You can decide the time for which the desired output should be held high low This can be achieved by entering the time in the Status upheld column For example if you enter the value of Status upheld 5000 it would mean the corresponding output say digital output 4 should be high would be upheld only for 5 seconds After this time has passed the action will be terminated and the output will return to its original state The value is in milliseconds and the maximum acceptable value is 2147483648 approx 24days If 0 is entered it would mean a permanent change in status of corresponding output The last setting is the State here you can select the desired state of the output when the action would be performed Click under the column State and select from the available three states This completes the configuration of Box N12R actions To add more actions repeat the above procedure again Note Only digital outputs are supported by Box NI2R There are no analog outputs available on Box NI2R So you can only have actions for digital outputs Teltonika Alarm and Control Configurator User manual 4 5 Remote commands Remote commands are also a newly added feature to the previous Alarm configurator With the help of remote commands you have more control over your module and
13. op up and display the BoxN12R connected to your PC If there are more than one BoxN12Rs you can select the desired BoxN12R and press Ok This will restart the corresponding BoxN12R If you don t see any device make sure you have connected the BoxN12R properly and press Refresh 5 Important notes JAVA runtime environment version 5 update 11 or higher should be installed on the PC reference is http www java com en download windows_xpi jsp 6 Support Before contacting for support make sure that you went through the above manual thoroughly If you are still facing problems feel free to contact our technical support team at support teltonika lt we would be glad to help you
14. security On the front panel of Box N12R is a switch which allows selection of I O or AT mode Select the I O mode and power up the module 3 Make sure that you have TACC imlet running in the Box N12R a You can check this by connecting Box N12R s port 2 to the computers serial port Then launch Nokia Configurator click on Imlet loading gt cable A window will appear under the dialog box Module should appear TACCImlet x x x version of the imlet may vary accordingly b When you will click on this imlet an imlet will appear in IMlet list Click on this imlet and wait if the start button will appear deactivated it means the imlet is running and you can simply press OK exit the window and close Nokia configurator c However if start button is active click on it so as to start the imlet and then press OK to exit the window d Please note that you only have to run the imlet once Thereafter whenever you would power up Box N12R the imlet would start automatically This can be confirmed by blinking of output LED 9 If this LED is blinking it means the imlet is running properly 4 Make sure that you have JAVA runtime environment version 5 update 11 or higher installed on the PC reference is http www java com en download windows_xpi jsp 5 Using the cable for port 3 provided in the package of Box N12R connect port 3 of Box N12R to the serial port of your computer 6 Launch TACC 7 If you are using TACC
15. that too from a remote location These commands are executable through your mobile phone either by sms or a call The user friendly interface of TACC gives you complete freedom to define the commands and the liberty to decide the corresponding actions for them Before you start configuring remote commands make sure that you have configured Box N12r actions version 2 0beta Alarm amp Control Configurator 1 Z TELTONIKA Remote Commands Name of command Type of command Member s Action s Change valve sms Group 2 ive FE ON sms Group 1 Turn ON fire extinguisher Close gas gas leak sms Admini Close gas valve 4 Add Bo actio 3 Available Selected lose gas valve ead Valve Turn ON Fit tinguishi gt gt T 2 dd commang Delete command Figure 5 Remote commands menu Click on the Remote commands icon 1 the first step is to create a command and give it a name Click on Add command 2 a blank row will appear under the column Name of command double click 3 and type the name of the command you wish to create The next option is Type of command here you decide the medium of your command The command can be executed either by sending a sms or by giving a call Note When you would wish to send a remote command through sms the text of the sms should be the same as the Name of the command You can assign the authorized member group who would