1. page 6 6 User manual TEMPERATURE CONTROLLER 6 7 2007
2. firstly have to be set up in trial period regime At the end of this period have to be entered PIN code see ERASE MEMORY to continues working of the controller and system To avoid system stops in future set up the option like that 00 00 00 Confirm the setting by the button M To exit the option use the button 4 5 ALARM CONDITION To use the option SEARCH ALARM for exceeded values you must set up the option ALARM CONDITION in advance gt Tmax 16 60 25 The T max setting for maximum available temperature is good to be set up according the season of the grain storage Tmin 00 15 00 The T min is setting for the minimum available temperature Values below 0 C are not provided The change is performed by the buttons 21 and M Confirm the setting E 4 6 BACKLIGHT gt BACKLIGHT ON BACKLIGHT OFF By this option you may switch off on the backlight of the display Use the buttons Confirm the setting E 4 7 DEFAULT SETTINGS CONFIRM DEFAULT lt The confirmation of this option will restore the original settings of the controller The settings BACKLIGHT and SLEEP are exceptions ERROR MESSAGES CABLE NOT ATTACHED There is no connection between the devices The most probable cause of this damage is a broken connection between the ropes with the sensors and the controller Check carefully for a mechanical damage of the equipment and contact the firm supplier of the system
3. serves for total erasing of the controller s memory In case the controller memory is necessary to be erased enter the PIN code by buttons M Confirm erasing operation by the button After a few seconds on the display will appear the label NO DATA This means that the memory is totally erased To restore the memory please follow the steps SETTINGS gt READ DATA BASE On the display will appear label SEARCH AND SAVE BASE After a few seconds on the display will be shown the result of the search For example FOUND DEVICES 06 NEW DEVICES 06 END OF SEARCH If the controller hasn t registered none or incomplete number of devices the label will be NO DEVICES END OF SEARCH Repeat the operation or contact the provider of the system 3 OPTION SEARCH ALARM By this option SA of the main option settings you may see only these sensors which have too high temepretature values see below SEARCH ALARM SILO 01 CABLE 01 LEVEL 04 49 5 4 6 User manual TEMPERATURE CONTROLLER 6 7 2007 If in the base there is one or more sensors with higher temperature than the set up in the ALARM CONDITION SETTINGS you may see it by this option using the button A After you check the last sensor on the display will appear the label END OF ALARM SEARCH Leave by the button 4 OPTION SETTINGS By this option you can make the follow settings READ DATA BASE TIPE OF READING TIME amp DATE T
4. RIAL TIME ALARM CONDITION BACKLIGHT DEFAULT SETTINGS 4 1 READ DATA BASE Reading the memory of the controller READ DATA BASE as wellas ERASE MAMORY are system options for use only by the firm supplier If itis necessary the option is accessible by entering PIN code see ERASE MEMORY Choose the option READ DATA BASE enter the PIN code and confirm by the button The controller will search the devices installed in the system If everything is correct aftera few seconds onthe display will appear the label FOUND DEVICES 06 NEW DEVICES 00 END OF SEARCH This means that it has found the existing 6 devices and not a single new one Exit with the button 8 4 2 TYPE OF READING Working regime of the controller By this option you can choose one of two working regimes of the controller C CONTINUES automatical regime M MANUAL manual regime Confirm the chosen regime by the button Es 4 3 TIME amp DATE To set up the data and or the time and minutes confirm by the button and on the display you will see TIME amp DATE 08 05 06 18 25 Use the buttons l to choose the couples of figures The couple is chosen when undet it there is the symbol The change is performed by the buttons B n M Confirm set up by the button To exit of the option use the button E User manual TEMPERATURE CONTROLLER 6 7 2007 page 5 6 4 4 TRIAL TIME Each controller
5. USER MANUAL TEMPERATURE CONTROLLER model 6 7 2007 ah ea 6 54 vo a 4 a TEMPERATURE CONT ROLLER SILO Ne ROPE Ne Made by INFOTECH GROUP Ltd I BASIC DETAILS OF THE PANEL TEMPERATURE CONTROLLER Working regime LCD Level of sensors 1 2201 2 and 3 Data transfer PC controller Butto for enter exit ot the menu 4 The controler is switched on The display usually shows the temperature of the sensors ropes siloses 01 04 silo 01 04 C working regime On the left side of the LCD is shown the working regime of the controller C continues or M manual Manual regime the controller is loading the data of the sensors a single time To reload data must select MANUAL from TYPE OF READING from the menu again see below The controller doesn t save data and hour of the last measure That information is available only by the software programme InfoNav Continues regime the controller loads data from the sensors automatically in every 3 minutes During the loading on the LCD is shown READING DATA Hold on a few seconds until the controller reloads new data from the sensors Under the working regime are shown the levels of the sensors 01 first level always on the bottom of the silo WORK WITH THE MENU OF THE CONTROLLER Basic menu is reached by the button To use and or set up any of the four basic options move the
6. arrow on the LCD by the buttons and until the arrow gets in front of the option All options are reached by pushing of the button confirm the made set ups push the button Es If you don t wish to memorize the set ups and or you wish to leave the option please push the button E User manual TEMPERATURE CONTROLLER 6 7 2007 page 3 6 The basic menu contains the following four options 08 05 06 18 25 gt DISPLEY DATA ERASE MEMORY v SEARCH ALARM SETTINGS Only three options can be shown on the display To reach the last or the first one use the buttons 2 and To use one of the four options after it is chosen you must push the button 1 OPTION DISPLAY DATA In initially switching of the controller on the display for a few seconds is shown INFOTECH GROUP VER 6 7 After that this label is replaced automatically by data of the sensors or label READING DATA In case the controller is in automatical regime of work which means that the controller is reloading the data If you enter the basic menu you may go back again to the data of the sensors by choosing DISPLAY DATA by the button E or by pushing several times the button E 2 OPTION ERASE MEMORY This option is for service use only To access this option you need unique 4 digit PIN code Enter PIN 0000 If it is necessary the provider of the system will give you the PIN code ERASE MEMORY
Download Pdf Manuals
Related Search
Related Contents
Fierce Herbicide GLM1 取扱説明書 Mode d`emploi - ESPP Tennis 008532_M_Inst P&S.FH11 Version française SMARTPOOL SMART-KLEEN™ (NC22) ROBOTIC POOL D-DGEP-01A-09 Mathématiques Eureka 7700 Vacuum Cleaner User Manual Global Door Controls TH1103-1-1/8-LH Installation Guide 498 05 00 Rev0 Folheto de Instruções Sec. Profissional PH2100 Copyright © All rights reserved.