Home

iLED-30 USER MANUAL

image

Contents

1. button to change the DMX 512 address Once the address has been selected press ENTER button to storing the setting To go back to the functions without any change press the MENU button again Please refer to the following diagram to address your DMX 512 channel for the units 4 DMX 512 channels DMX Channels Each iLED 30 has 4 control channels DMX channel value refer to the 5 page 5 APPENDIX DMX Primer There are 512 channels in a DMX 512 connection Channels may be assigned in any manner A fixture capable of receiving DMX 512 will require one or a number of sequential channels The user must assign a starting address on the fixture that indicates the first channel reserved in the controller There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required Choosing a start address should be planned in advance Channels should never overlap If they do this will result in erratic operation of the fixtures whose starting address is set incorrectly You can however control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation In other words the fixtures will be slaved together and all respond exactly the same DMX fixtures are designed to receive data through a serial Daisy Chain A Daisy Chain connection is where the DATA OUT of one fixture connects to the DATA IN of the next fixture
2. The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 is Data positive S 14 ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111 Photometrice WHITE 3 1980 504 230 136 104 LUX 5 1 0 25 1 2 2 4 6 8 10 Distance m 0 88 1 77 2 66 3 30 4 43Diamerer m RED 825 209 94 52 36 LUX 2 1 0 25 1 2 3 2 4 6 8 10 Distance m 0 88 1 77 2 66 3 55 4 43Diamerer m GREEN 1271 410 195 93 LUX 2 1 0 25 4 2 x 1 2 4 10 Distance m 0 88 1 77 2 66 3 55 4 43Diamerer m 3 221 71 33 19 16 LUX 2 1 0 25 1 2 3 2 4 6 8 10 Distance m 0 88 1 7
3. 7 2 66 3 55 4 43Diamerer m 15 ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111 General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently Usage and environment are contributing factors in determining frequency As a general rule fixtures should be cleaned at least twice a month Dust build up reduces light output performance and can cause overheating This can lead to reduced lamp life and increased mechanical wear Be sure to power off fixture before conducting maintenance Unplug fixture from power Use a vacuum or air compressor and a soft brush to remove dust collected on external vents and internal components Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens Gently polish optical surfaces until they are free of haze and lint The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Cl
4. Im 685 fc 7364 lux Beam A E E E 19 3 Field THERMAL Maximum ambient temperature 05 F 35 C CONTROL amp PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 Shield pin 2 pin 3 PYOtOcols ccscscsccccsccscccsescccssescscsscsecsscccsccsssssscesscscsscssscssessscssscsscssscssecssesseesserees 512 USITT DMX Channels cisaisesccessccsessccsencsvensevecnstesesvecsonssesacssoccshacevecessaccessecessusstosveedesesevetssons duicsssecsesesssncseese4t ORDERING INFORMATION ILED 30 Black sccsccosccossoscessesssssscsoscocssossecssossecssenssessecssessenssssssssonssonssesssessossesssesseeseess ILED 30 SUV LLB D 30S TLED 30 WARRANTY INFORMATION WaALTANLY cs
5. ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111 ILED 30 USER MANUAL Snapshot OK on Dimmer Outdoor Sound Activated Option DMX 512 Master Slave 115V 230V Switch Please read these instructions carefully before use ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111 TABLE OF CONTENTS 1 BEFORE YOU BEGIN WHAT IS INCLUDED SAFETY INSTRUCTIONS 2 INTRODUCTION FEATURES DMX CHANNEL SUMMARY PRODUCT OVERVIEW 3 SETUP FIXTURE LINKING Data Cabling DMX Data Cable Cable Connectors 3 Pin to 5 Pin Conversion Chart SETTING UP A DMX SERIAL DATA LINK MASTER SLAVE FIXTURE LINKING MOUNTING Orientation Rigging 4 OPERATING INSTRUCTIONS MAP MENU FUNCTIONS OPERATION 12 Standalone amp Master Slave Operation 12 DMX 512 Mode PHOTOMETRICS 15 GENERAL MAINTENANCE 16 CEAIMS 16 TECHNICAL SPECIFICATIONS ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111 1 BEFORE YOU BEGIN What is included 1xiLED 30 e Users Manual Unpacking Instructions Immediately upon receiving a fixture carefully unpack the carton check the contents to ensure that all parts are present and have been received in go
6. REW 4 OPERATING INSTRUCTIONS is soid separately Navigating the Control Panel Access control panel functions using the four panel buttons located directly underneath the LED Display Button Function lt MENU gt _ To select the programming functions lt ENTER gt confirm the selected functions lt VAL gt To setting DMX value up lt VAL gt To setting DMX value down ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111 Menu Map ADDR 1 511 Shnd 9 SVAL 1 8 LEd On OFF Fadj Fadj test test Fhrs Fhrs 1 9999 rSet rSet iLEd 10 Menu Function ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111 Menu Function Values Display ADDR Set the DMX address of the unit Set between 1 and 511 Each unit is 4 DMX channels Shnd Sound controlled built in AO to 9 programmes SVAL Speed Fade Settings single color 1 to 8 selection for Shnd programs blnd Control on off function of the light ybo Unit is blacked out off nbo Unit is on and pre programs can be used LED Setting for the LED display to be on on LED display is always on or off when not being used OFF The LED display will turn off after 10 seconds Press the MENU button to illuminate the LED display In this mode pressing the ENTER button will change the color and hold Press Enter again the next colo
7. al Features Durable and weather resistant IP65 rated e LED display with lock out feature e Low power consumption DMX Channel Summary Channel Function Value Level 1 Red 0 gt 100 000 255 2 Green 0 gt 100 000 255 3 Blue 0 gt 100 000 255 4 Dimmer 0 gt 100 000 127 Strobe Slow gt Fast 128 199 Color Scroll Fast gt Slow 200 255 ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111 Product Overview Powerin Connector DMXIn Connector DMX Out Connector ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111 3 SETUP Fixture Linking You will need a serial data link to run light shows of one or more fixtures using a DMX 512 controller or to run synchronized shows on two or more fixtures set to a master slave operating mode The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support Important Fixtures on a serial data link must be daisy chained in one single line To comply with the EIA 485 standard no more than 32 devices should be connected on one data link Connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Maximum recommended serial data link distance 500 meters 1640 ft Maximum recommended number of fixtures on a serial
8. atically Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other 3 PIN TO 5 PIN CONVERSION CHART Note If you use a controller with a 5 pin DMX output connector you will need to use a 5 pin to 3 pin adapter The chart below details a proper cable conversion 3 PIN TO 5 PIN CONVERSION CHART Conductor 3 Pin Female output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Do not use Do not use Do not use Do not use Setting up a DMX Serial Data Link 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector Controller Universal DMX DMX IN DMX OUT Continue the link DMX IN DMX OUT ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111 Master Slave Fixture Linking 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first fixture which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector Then pro
9. c 4 4sec 5 5 6 6sec 7 8sec 8 10sec 12 ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111 A4 iLED 30 reacts to sound only 1 8 Option changing color with the music When the music sound stops the LED PARCan stays on the last color A5 iLED 30 reacts to sound only 1 8 Option changing color with the music When the music sound stops the LED PARCan turns off after 10 seconds A6 iLED 30 reacts to sound only 1 8 Option changing color with the music When the music sound stops the LED PARCan will be change color once after 3 seconds A7 iLED 30 reacts to sound only 1 8 Option Strobing quickly and changing color with the music When the music sound stops LED light will turn off after 1 2 seconds 8 iLED 30 reacts to sound only 1 8 Option Glittering and changing color with the music When the music sound stops LED light will turn off after 2 4 seconds 9 iLED 30 single color selection 1 8 1 Red 2 Orange 3 Yellow 4 Green 5 Cyan 6 Blue 7 Magenta 8 White 13 ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111 DMX 512 Mode If you use a universal DMX controller to control the units you have to set DMX address from 1 to 511 channel so that the units can receive DMX signal Press the MENU button up to when the Addr is showing on the display Pressing ENTER button and the display will light on Use VAL VAL
10. ccscsrcssecccesessscsscenssscssscsssscssscsssessessessessersesssssessessssssssesssseeneees L Vear limited warranty 17 SIZE
11. ceed to connect from the output as stated above to the input of the following fixture and so on 3 If the client requests the AC power cable with the plug we may configure it TO DMX CONTROLLE R TO AC POWER SUPPLY GND GREEN YELLOW CABLE NEUTRAL WHTE BLUE CABLE LIVE BLACK BROWN CABLE 1 GND 2 DATA 3 DATA often the setup for Master Slave and Standalone operation requires that the first fixture in the chain be initialized for this purpose via either settings in the control panel or DIPswitches Secondarily the fixtures that follow may also require a slave setting Please consult the Operating Instructions section in this manual for complete instructions for this type of setup and configuration Mounting ORIENTATION This fixture may be mounted in any position provided there is adequate room for ventilation RIGGING Hanging Clamp It is important never to obstruct the fan or vents pathway Mount The fixture using four 8mm screws Adjust the angle of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs e When selecting installation location take into consideration lamp replacement access and routine maintenance Safety cables must always be used e Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation M8 SC
12. data link 32 fixtures Data Cabling To link fixtures together you must obtain data cables You can purchase certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DMX DATA CABLE Use Belden 9841 or equivalent cable which meets the specifications for EIA RS 485 applications Standard microphone cables cannot transmit DMX data reliably over long distances The cable will have the following characteristics 2 conductor twisted pair plus a shield Maximum capacitance between conductors 30 pF ft Maximum capacitance between conductor and shield 55 pF ft Maximum resistance of 20 ohms 1000 ft Nominal impedance 100 140 ohms ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111 OUTPUT CABLE CONNECTORS Cabling must have a male XLR connector on one end and a female XLR connector on the other end COMMON INPUT DMX Termination reduces signal errors and to avoid signal transmission problems and interference It is always advisable to connect a DMX terminal Resistance 120 ohm 1 4W between pin2 DMX and pin3 DMX of the last fixture CAUTION Do not allow contact between the common and the fixture s chassis ground Grounding the common can cause a ground loop and your fixture may perform err
13. ean the internal optics at least every 30 60 days Claims Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchandise It is the customer s responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping Any other claim for items such as missing component part damage not related to shipping and concealed damage must be made within seven 7 days of receiving merchandise 16 ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111 Technical Specifications WEIGHT amp DIMENSIONS LG Sth eiscscessciessecsssssescsiedccsscevsvensscsseseossoisevsssosstersscondesssdsesccescacosssteassescessosescsosssvee 10 9 418 mm Width 3 6 in 92 mm i AAEE Si E A 1s im 191 mnn AEE ia E EES A 75 IDS 2 POWER Operating Voltage 100V 240V 50 60 Hz Power Consumption 47W 0 47 Inrush Current 1 0A at 120V Power Factor At 1203 LIGHT SOURCE LED 30 X 1W 10 Red 10 Green 10 Blue PHOTO OPTIC at
14. f the fixture e Make sure there are no flammable materials close to the unit while operating Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain e Maximum ambient temperature is 95 F 35 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts Don t connect the device to a dimmer pack e Make sure the power cord is never crimped or damaged Never disconnect the power cord by pulling or tugging on the cord Avoid direct eye exposure to the light source while it is on Do not daisy chain power to more than 20 units at 120V or 40 units at 230V Caution There are no user serviceable parts inside the unit Do not open the housing or attempt any repairs yourself In the unlikely event your unit may require service please contact your vendor ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111 2 INTRODUCTION Features 4 channel DMX 512 LED LIGHT with ID addressing e Blackout static dimmer strobe pulse e RGB color mixing with or without DMX controller Addition
15. od condition Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling Save the carton and all packing materials In the event that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing AC Power This fixture has an auto switching power supply that can accommodate a wide range of input voltages The only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is within the range of accepted voltages This fixture will accommodate between 100V and 240V All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch ORDER DIRECTLY TODAY www BulbAmerica com or CALL TOLL FREE 888 505 2111 Safety Instructions Please read these instructions carefully this includes important information about the installation usage and maintenance of this product Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet e Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel o
16. r will output test In this mode a range of colors will cycle through when ENTER is pressed Fhrs Display the number of operational hours of the unit by pressing ENTER rSet Reset the unit by pressing ENTER 11 ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111 Operation Standalone amp Master Slave Operation When multiple units are linked together via 3pin XLR cables sold separately the first unit in the chain will act as the Master and will send data DMX 512 to the other units Slaves By linking the units in master slave connection the first unit will control the other units to give an automatic synchronized light show The uint is normally without sound activated function If the client request the unit with sound activated function and it is only used in the indoor case we may configure the function iLED 30 has built in programs that are accessed via Shnd Menu Shnd Pre Programmes SVAL Settings AO The LEDs fade continuously between 1 8 Select one fade time from to 8 the preset 12 colors in loop mode 1 sec 2 2sec 3 3sec 4 4sec 5 5 6 7 8 8 10 1 The preset 12 colors step continuously 1 8 Select one color hold time from 1 to 8 in loop mode 1 lsec 2 2sec 3 3sec 4 4sec 5 55 6 6sec 7 8 8 10sec A3 Glittering the color changes constantly 1 8 Select one color hold time from 1 to 8 in loop mode 1 lsec 2 2sec 3 3se

Download Pdf Manuals

image

Related Search

Related Contents

  Berlin Heart  Low Air Loss Mattress Replacement System - PHC    T3 Classic connected to IP Office  Compact, high-performance WUXGA installation  1042 - Jims  Les jeux dangereux  Haier HLP140E tumble dryer  Quer SLU0049 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file