Contents
1. O Figure 18 2 5 Stabilizer Detail AC Tonnage Stabilizer KVA 1 0 3 1 5 4 2 5 3 Maintenance 3 1 Cleaning air filter Clogged air filter decreases cooling efficiency Clean filter at interval of two weeks K J Lift Front panel up to an angle keeping it attached until it makes a clicking sound Disconnect power supply before cleaning indoor unit Clean units with soft dry or moist cloth with water or cleanser Use support pole to hold the front panel at its place after lifting it 18 48663967 Rev 1 Contents Gei TRANE Hold the air filter handle and lift slightly to release it from holder pull downwards to remove air filter from indoor unit e Clean air filter with a vacuum cleaner or water dry in cool place Remove air freshening filters from its supporting frame Clean air freshening filter monthly and replace at an interval of 4 5 months e Install air freshening filter into its original position Insert upper part of air filter and place filter into position make sure left and right edges align correctly 3 2 Maintenance Unit not in use for long duration If you do not plan to use unit for a
2. If the trouble has not been corrected please contact a local dealer or the nearest customer service centre Be sure to inform them of the detailed malfunctions and unit model number Do not attempt to repair the unit yourself Always consult an authorized service provider 21 48663967 Rev 1 Contents Gei TRANE 4 1 Error Messages and Actions Error Error Description Error Displayed on Unit Response Action to be codes Remote Taken by user 0x01 EEPROM Error 01 EEPROM communication error communication error Please Contact Customer Condit ontac Care Unit Stops Working Customer Care 0x02 Compressor Failure Error 02 OutDoor Unit error or refrigerant Error Please Contact leakage Customer Care 0x03 Filter choke Error Error 03 Filter choke error Unit Operates as per Clean Filters Clean the filter user settings 0x04 Indoor Room Error 04 Room temp Cool mode or Dry Contact temperature sensor sensor failure Please mode Unit operate Customer Care error Contact Customer Care with Compressor OFF Fan mode Operates as per user setting 0x06 Indoor coil Error 06 Indoor temp Cool mode or Dry Contact temperature sensor sensor failure Please mode Unit operate Customer Care error Contact Customer Care with Compressor OFF Fan mode Operates as per user setting 0x08 Communication error Error 08 Communication Stop indoor unit and Contact error Please Contact
3. Company will put in reasonable efforts to promptly attend to any breakdown complaint lodged by the customer at company s authorized sales and service dealer or branch office or at the centralized customer care centre Compressor Warranty Clause The 5 year compressor warranty will continue even after the expiry of 1 year period from the date of purchase This warranty covers the compressor only Gas charging is included only when the compressor is defective amp inoperative During the additional warranty period it does not cover parts or any part such as Condenser Coil Evaporator Coil Capillary Suction Line Electronic Parts Other terms 1 This warranty is confined to the first Purchaser of the Product only amp is non transferable 2 The warranty for both machine and compressor will terminate upon expiry of the warranty period irrespective of whether or not the Product has been in use for any reason whatsoever 3 The warranty for both Product and the compressor will automatically be terminated on the date of expiry of the warranty period No notice of expiry of warranty will be given at any time 4 Compressor warranty will be applicable only if the Product is maintained by authorized dealers of the company 5 For Products installed beyond the municipal limits of the jurisdiction of the authorized service centre company s service centre authorized dealer s service centre all expenses incurred in collection of the
4. Contents Gei TRANE In high humidity conditions user can select dry mode 2 4 2 4 Fan Mode 1 Press MODE Col to select fan mode see FAN shown on display Set point temperature cannot be adjustable Fan speed can be adjustable 2 4 2 5 Sleep Mode Display Figure 11 1 Press to activate sleep mode operation The set temperature will automatically increase by 1 C for each hour for four hours After 4 hours unit will stay at latest temperature E g if the set temperature is 24 C and sleep mode is started After first hour set temperature will increase to 25 C and at the end of fourth hour set temperature will be at 28 C The unit will stay at 28 C Press again to disable sleep mode Set point temperature and fan speed can be adjustable 2 4 2 6 Turbo Mode 1 Press to activate turbo mode See TURBO on remote display Display Figure 12 Enables instant cooling by automatically adjusting fan speed to turbo level Fan speed cannot be changed while unit is in turbo mode The display will not show the fan speed bar Refer Figure 13 Display Figure 13 User can set this mode for fast cooling Press again to disable turbo mode 2 4 2 7 Fan speed 1 Press fan speed to change fan speed Fan speed can be changed as below Low gt Medium F _ High gt amp Auto Ze Display t s s Figure 14 Fa
5. Product or part s thereof from the company s service centre authorized service centre authorized dealer s service centre as well as expenses incurred in connection with deputing of service personnel technicians towards to and fro travel conveyance and other incidentals etc together referred to as Transportation and Handling Expenses shall be borne by the Purchaser 6 The company or the authorized sales and service dealer will advise the Purchaser whether to effect repairs replacement at the site of installation or at the company or authorized sales and service dealer s premises and the decision of the representative shall be final 7 The company reserves the right to replace the defective part with a substitute equivalent part without affecting the performance of the Product 8 In case of any transit damage the Product shall be repaired by the concerned service centre on charges and warranty for the unexpired period will continue 9 In the event of repairs replacement of any part s of the Product this warranty will thereafter continue and remain in force only for the unexpired period of the warranty Moreover the time taken for repair replacement and in transit whether under the warranty or otherwise shall not be excluded from the warranty period 10 The warranty extended herein is in lieu of implied conditions and warrants under the law amp is confined to the repair or replacement of defective parts and does not cover any c
6. any of the following set point fan speed mode sleep and also if button is pressed 6 Unit will not exit TRANE mode if user changes any of the following swing button multi room or night latch button 7 The indication of TRANE mode is D button with red back light and the remaining buttons with light OFF The back light will go OFF after 20 seconds from last operation of remote controller 2 4 2 2 Cool Mode 1 DRY 4 FAN a o om ES Figure 8 1 Press MODE Gei to select cool mode see COOL shown on display Refer Figure 8 2 Press to set fan speed if required 3 Press O or to increase or decrease set temp Set temperature range is 17 C 30 C This is normal mode of cooling User can set room temperature and AC will run to attain the set temperature Temperature can be set based on energy consumption Refer below table Zone 1 Red Uneconomical O 8 4 Zone 2 Yellow Higher energy consumption He j ky Zone 3 Light green Economical Zone 4 Dark green Lower energy consumption 2 4 2 3 Dry Mode 1 Press MODE 7 to select dry mode see DRY shown on display Refer Figure 10 In dry mode default set temperature is 25 C Set temperature and fan speed cannot be changed Unit will operate at low fan speed for maximum moisture removal Display Figure 10 15 48663967 Rev 1
7. outdoor unit Customer Care Customer Care 0x09 Low battery Error 09 Low battery Operates indoor unit Change battery please change the and outdoor unit as battery per user setting Wa Input Power Error Error 10 IDU Input Check the power Power Problem Please cord Contact Contact Customer Care Customer Care Unit stops working 0x0B IDU Error Fan failure Error 11 IDU Error Fan Contact Failure Please Contact Customer Care Customer Care 0x0D Communication error Error 13 Communication Cool mode or Dry Contact IDU to ODU error IDU to ODU mode Customer Care Please Contact Customer Unit will run with Care Compressor OFF Fan mode Run IDU as per user settings 22 48663967 Rev 1 Contents Gei TRANE Error Error Description Error Displayed on Unit Response Action to be codes Remote Taken by user Ox0E Outdoor discharge Error 14 Outdoor Cool mode or Dry Contact temperature sensor discharge temperature mode Customer Care error sensor error Please Unit will run with Contact Customer Care Compressor OFF Fan mode Run IDU as per user settings Ox0F Outdoor EEPROM Error 15 Outdoor Cool mode or Dry Contact parameter reading EEPROM parameter mode Customer Care error reading error Please Unit will run with Contact Customer Care Compressor OFF Fan mode Run IDU as per user settings 0x13 IPM module failure Error 19 IPM module Cool mode or Dry Contact failure Plea
8. 5 C to clean it can deform or discolour front panel Do not dry filters near fire It can ignite or deform them Do not drop or throw remote control It can cause malfunctioning or breakage Do not use remote under direct sun light It can create display issues 9 48663967 Rev 1 Contents Run in the Green Zone Set the unit at TRANE mode for efficient performance It will save energy It is suggested to use TRANE recommended stabilizer For stabilizers check with local TRANE distributor 1 2 Product Overview Indoor unit Indoor unit Front panel Air inlet Air filter Air outlet Horizontal air flow grille LED display Remote control NOORWN Outdoor unit 8 Connecting pipe 9 Connecting cable 10 Stop valve Outdoor unit CUT Figure 1 10 48663967 Rev 1 Contents 2 Operation 2 1 Remote Operation Make sure power is ON Select the room which needs to be controlled e Refer section 2 4 2 for different functions of remote 2 2 Manual and Auto Restart Operation Manual operation can be used temporarily in case remote controller is not available Lift Front panel up to an angle it stays attached with a clicking sound Refer Figure 2 Do not lift front panel at an angle above 60 degrees Do not apply too much force Figure 2 When you press manual control
9. ANE mode Power ON OFF NA ON OFF Night A latch mode Pe WN CSE SEAS Shows night latch mode a ge night latch mode on TRANE 8 LS activation selection GES lock deactivation Multi room Sg Selects the split air Shows room selection as Room A MASTER BEDROOM j conditioner to control for each room AC settings Configuration NA ERROR MESSAGE Indicates error am Shows different efficiency NA f s zone Refer section 2 4 2 2 NA 7 DUT Shows current outdoor ambient temperature NA Roam Shows current room temperature NA Not Applicable 2 4 1 Range of Operation 2 4 1 1 Lock and Indoor Unit range Range Indoor Range Outdoor without any obstacles 15 meter 1000 meter 48663967 Rev 1 Contents S TRANE 2 4 1 2 Remote and Indoor Unit range Range Indoor Range Outdoor without any obstacles 14 meter 160 to 175 meter 2 4 2 Functions 2 4 2 1 TRANE Mode 1 Press to start or stop TRANE mode Refer Figure 7 2 The unit when powered ON by remote control starts with TRANE mode by default 3 TheTRANE mode will set room temperature and fan speed automatically to provide an energy efficient and comfortable environment hence the energy efficiency meter always shows dark green Refer Figure 5 4 It will set room temperature automatically based on outdoor temperature 5 Unit shall exit TRANE mode if user changes
10. S TRANE IMVERTER gt A SPLIT AC WITH e T 2 INTERACTIVE Ee REMOTE Applicable Series IN 1 Inverter Models R410a TRANE SPLIT AC Pictures of the actual product may differ as per the product purchased ID ingerson Rand Inspiring Progress Gei TRANE Dear Customer We are TRANE a global leader in heating ventilation and air conditioning equipment We come from the house of Ingersoll Rand a 14 billion company with around hundred manufacturing facilities worldwide Our 1500 patents for heating air conditioning and ventilation products are testimony to our spirit of innovation Today we bring innovation to your home At TRANE we create products that are intuitive and easy to operate They are simple yet technologically evolved for modern living TRANE Interactive AC is one such product The TRANE Interactive AC assesses manages and gives feedback on your in home climate The ultra slim design brings together simplicity and elegance that complements your home Once it s in your home a whole new world of evolved living experiences will open up to you The Trane mode optimizes comfort and efficiency Efficiency meter on the remote keeps you updated on energy consumption and therefore keeps bills in check The intelligent cooling sets the most suitable temperature for your home by analyzing the temperature outside TRANE AC creates home environment that promises new levels of comfort efficie
11. T TO NETWORK E S previous settings technician on the remote S SET POINT TEMP Switch ON main EE INFRARED ACTIVATED power check the P NO NETWORK FOUND plug Lock with AC Lock not installed NIGHT LATCH FAILED LOCK NOT INSTALLED Lock is not in network Night latch not NIGHT LATCH FAILED Change Battery of Lock or Check Lock is PLEASE CHECK YOUR operating in Network by LOCK doing Home Away Operations NIGHT LATCH FAILED Door Open DOOR OPEN Close door Refer Section 2 3 1 for LED indications 24 48663967 Rev 1 Contents Warranty Terms amp Conditions Ingersoll Rand hereinafter referred to as the company warrants to the purchaser that this TRANE split air conditioner Product carries a warranty for the period mentioned above commencing from the date of purchase The company will repair or replace free of charge any part or parts of the Product if the defect is due to the defective material or workmanship Warranty involves repairing of defective product parts and does not entitle the purchaser for the replacement for a new product Preventive Maintenance Maintenance check up will be carried out 2 times in a period of 12 months from the date of invoice on request from the customer and will include General cleaning and brushing up of dirt and muck Cleaning of air filter Checking of electronic parts and its contacts Breakdown Complaints
12. button Figure 3 the unit is switched on at the following default conditions MODE COOL FAN SPEED MEDIUM SWING AUTO SET TEMP 24 C Lower the front panel to its initial position TSIXXMSXBSBCX Model Series Manual control button Figure 3 Use object not more than 5mm in diameter to press manual control button To restore remote control operation use remote control directly The Display LED status will not change when unit is operated through manual control button Auto Restart Function Power cut during operation will stop the unit completely Unit starts automatically with all previous settings saved in memory function when the power is restored 11 48663967 Rev 1 Contents Remote will be in sleep condition after 20 second from last key pressed Remote wakes up from sleep condition on first key pressed and does not sends command to AC unit and update just the display settings 2 3 Indicators 2 3 1 Indoor LED 1 LED 2 LoL Figure 4 LED Indication Unit status LED1 LED2 Stand by RED OFF Stand by Error on PCB RED RED Operating without TRANE mode GREEN OFF Operating without TRANE mode and Error on PCB GREEN RED TRANE mode active GREEN GREEN TRANE mode active Error on PCB GREEN GREEN and RED Blinks alternately Button press on remote GREEN blink once No change Sound Indi
13. cation Unit status Buzzer Unit powered ON in stand by state One short beep Mains Power ON Unit powered ON in operating state One short beep Mains Power ON Unit powered OFF stand by ON using remote One long beep Button press on remote One short beep 12 48663967 Rev 1 Contents S TRANE 2 3 2 Remote O umu 2 User Mode Trane Mode Figure 5 2 4 Remote Controls Room Temperature Acvtivated Night Latch Fan Speed Mode Indication Sleep Turbo Mode Set Temperature Outdoor Temperature Energy Efficiency Meter Error Message Display Room Selection Power ON OFF Fan Speed Increase Temperature Louver Direction Decrease Temperature Sleep Turbo Mode Cc T Mode Adjustment TRANE Mode ES mane L Remote Night Latch Multi Room Control Figure 6 48663967 Rev 1 Contents Symbol Button Function Display Description E F fan speed Air flow rate adjustment H Shows fan speed adjustment o Swing Changes the air flow NA Changes the air flow adjustment direction direction o Toggles between SLEEP Ne Shows mode selection nee TURBO and Default TI SLEEP TURBO activation Q Temperature Increase and decrease the ECET Shows temperature UP DOWN set temperature SET selection m Meds So nae coor DRY FAN Shows mode selection Adjustment for DRY and thrice for FAN COOL DRY FAN T TRANE Mode Activates TRANE mode Refer Figure 5 Activates TR
14. e months of purchase Complete warranty card is not presented to authorized personnel at the time of repair Product is not used according to the instructions given in the user manual Original serial number is removed tampered with Modification or alteration of any nature whatsoever is made in the electrical circuit physical construction of to the Product Installation repair work carried out by person agency other than authorized agency Site conditions that do not confirm to the recommended operating conditions of machine For any product related assistance please call on Toll free number 1800 102 9986 26 48663967 Rev 1 Contents
15. ectrical shock or fire Do not operate this unit with wet hands It can cause an electrical shock Do not pull power cord to remove power plug It can cause fire 5 48663967 Rev 1 Contents Do not use longer power cord and or share a same socket with other electrical appliances It can cause electrical shock or fire Do not place flammable spray near this unit It can cause ignition and explosion Do not insert or stick your hands into air intake or outlet vents It is dangerous and can cause injury Do not spray or wash the unit with water It can cause electrical shock and or malfunction of unit Do not splash water on the unit It can cause an electrical shock and or malfunction 6 48663967 Rev 1 Contents S TRANE Do not open windows and or doors for long duration when unit is ON This will decrease the cooling performance Do not splice power cord or use an extension cord It can cause fire or short circuit Do not insert any objects or fingers into the outdoor unit fan It may cause unit failure and or serious injury to the person Do not touch the fins at the back side of outdoor unit It can cause injury Do not step on top of outdoor unit Falling off outdoor unit can cause injury Make sure that all power supply connections are tight Check whether electrical grounding earth is complete If no
16. kes responsibility to supply only the compressor free of cost during warranty period cost of labour transportation and other incidental expenditures shall be borne by the customer after the lapse of first year Product warranty In areas where voltage fluctuates 10 of rated or usable voltage customer is advised to use a branded voltage stabilizer which steps up or down the incoming voltage to give an output of 230V For any fluctuation beyond the reasonable specified limit the company shall not be responsible and this warranty shall immediately stand terminated Earthing provision is necessary for safety Improper domestic wiring leading to hazards such as shock or fire is not covered under this warranty While the Company will make every effort to carry out the repairs at the earliest it however is made expressly clear that the company is under no obligation to do so in a specified period of time Any special indirect or consequential property or commercial damage of any nature whatsoever is not covered under this warranty The warranty is issued at Bangalore and Courts at Bangalore shall have exclusive jurisdiction over matters covered or flowing from this warranty The 1 year warranty is applicable to all parts except for Plastic amp Rubber parts Warranty is null and void in the following cases ili St Oy Sr Ze A he Warranty card is not duly filled and mailed back to the service centre for registering the Product within thre
17. long time perform following actions Clean indoor unit and filters Operate fan for approximately 30 minutes in order to dry inner side of unit Switch OFF the unit The outdoor unit requires periodic maintenance and cleaning The user must not do periodic maintenance of product on their own Contact dealer or service provider 3 3 Checks before operation Make sure wiring is not broken or disconnected Make sure air filter and front panel are installed Make sure air outlet or inlet is not blocked If air filter screen is blocked by dust or dirt the performance of the unit will be affected with higher operation noise and power consumption Air filter screen should be cleaned regularly 19 48663967 Rev 1 Contents Gei TRANE Preparation before season of use 1 Be sure that nothing obstructs air outlet and intake vents Refer Figure 19 2 Examine whether ground earth wire is correctly connected 3 Replace filters if necessary 4 Replace batteries of remote if necessary 5 Examine mounting bracket of outdoor unit if damaged contact servicing agency Figure 19 Ground wiring Connect Ground wire to exclusive device correctly if not employ specialist to install Grounding pole of socket should be grounded and wired reliably breaker and air switch with enough capability should be installed in fixed lines Do not connect grounding cable to gas pipe water pipe sewage pipe or any othe
18. n speed is adjusted automatically according to set point and room temperature when FAN speed is set to AUTO mode 2 4 2 8 Night latch Mode Only for units with TRANE Lock AC Remote Night latch Mode Activation Deactivation Display Figure 15 16 48663967 Rev 1 Contents S TRANE 1 Press on remote to activate or deactivate night latch mode on lock Night latch a will show on remote display after it started approximately 30 seconds for display to update 2 When night latch key pressed on remote displays message ENABLING NIGHT LATCH PLEASE WAIT After night latch mode activated a and the confirmation message NIGHT LATCH ENABLED will be displayed 3 When night latch key pressed on remote to disable the night latch displays message DISABLING NIGHT LATCH PLEASE WAIT After night latch mode deactivated confirmation message NIGHT LATCH DISABLED will be displayed and night latch e will disappear 4 Night latch mode helps user to prevent access to home even with valid credential Night latch mode operates only when Lock and AC are connected on network 5 Refer lock manual for night latch mode features 2 4 2 9 Multi Room 1 Press amp to activate multi room feature Multi room feature allow user to select and control two or more AC s with one remote from one room Press to switch and control AC in network Display Name of selected AC and its current settings shown on remote di
19. ncy and convenience Welcome to the family of TRANE 2 48663967 Rev 1 Contents 1 About this manual 1 1 Safety Information 1 2 Produ uct OV GEV OW encensa nEn N EE EEEa Ea eia Eaa a E AEE EET Ds Ope rea ti One AE i ei i NENA Een 11 2 1 Remote Operaatio Me mereeeegreegeeieddE Ceterum 11 2 2 Manual and Auto Restart Operation 11 2 3 Indicators 2 3 1 Indoor KE e ROMO bOro EEEE EEEE EE EENET eE 2 4 Remote Controls s stungen deen Ae aaea E ESAE 2 4 1 Range of Operation 2 4 1 1 Lock and Indoor Unit range 254 12 Remote anid door Ueleger 15 DA TT 2 4 2 1 TRANE Mode 2 4 2 2 Cool Mode 2 4 2 3 Dry Mode 2 4 2 4 Fan Mode 2 4 2 5 Sleep Mode 2 4 2 6 Turbo Mode 2 4 2 7 Fan speed 2 4 2 8 Night latch Mode Only for units with TRANE Locke 16 GEM ORT R an Eege 2 4 2 10 Swing Control 2 4 2 11 Power ON and OFF 2 4 3 Replacement of Batteries EENEG 17 2 5 Stabilizer Det ilonisirninnina eeneg 18 ER N 3 1 Cleaning air filter 3 2 Maintenance Unit not in use for long duration 3 3 Checks before operation 4 Troubleshooting ccscessossssssssecsssssesssessssesssesssesnseesnsssasesnsesnsestseeseeesastiaessasesaeesaeesaeesneesseetaeeeaeeeastgeesneesneesineesneeeet 21 4 1 Error Messages and Actions issiicicicscssasccscscsissnsssocssssansssinastissntessesiescaaciutucuchebespisbsasosoaunoottistessssseedsbtaiiaessivecesancacecpevoaiooboietendsgiv 22 Warrant
20. onsequential or resulting liability damage or loss arising from such defects Also the warranty in no case shall extend to payment of any monetary consideration whatsoever or replacement or return of the Product as a whole 11 The company s obligation under this warranty shall be limited to repair or providing replacement of part s only The maximum claim s if entertained by the company will be subject to the maximum retail price of the Product purchased or the purchase price whichever is lower 12 Any change of Address of the purchaser will be intimated to the concerned service centre dealer for continuation of warranty 13 The company shall not be liable or deemed to be in default for any delay or failure in performance resulting directly or indirectly from causes beyond its reasonable control including delay in repairing due to non availability of any part component labour problem presence of any foreign object or living creature e g Rat lizard Insects Ants etc inside the unit use of harmful chemicals usage of unit 25 48663967 Rev 1 Contents Gei TRANE 14 15 16 17 18 19 20 in an abnormally corrosive alkaline acidic atmosphere restrictions and regulations of the Govt public movement war and any other unavoidable circumstances vis a vis the import of supplies and raw material or if the company is otherwise prevented from performing its functions under this warranty While the company underta
21. r areas deemed unreliable for this purpose 20 48663967 Rev 1 Contents S TRANE 4 Troubleshooting Before requesting service perform following checks Symptom Remedy Indoor unit does not give cool air immediately when unit starts Compressor restarts after approximately three minutes to protect itself On compressor restarting units starts to give cool air again Unusual odor blowing from outlet when unit is started Open the door or window for 2 minutes and run the AC in Fan mode to allow fresh air inside the room This helps to remove odors from inside the room Sound of water flow during operation Formation of mist while cooling This is caused by refrigerant flowing inside the unit Room air is cooled quickly by cold air flow which looks like fog Creaking noise during start or stop Deformation of plastic because of temperature change Unit does not operate Check electrical system connections cords and fuses Check if power supply is within 10 of rated supply Decreased cooling efficiency Check set temperature Check for obstructions in air inlet and outlet Check air filters for dirt Check indoor fan speed om Check any other openings in the room Dada SW a9 ll gt ka A Check effective distance to indoor unit a Remote control does not be sehen work correctly Check low battery error indication on remote display
22. se Contact mode Customer Care Customer Care Unit will run with Compressor OFF Fan mode Run IDU as per user settings 0x14 High Low Voltage Error 20 High Low Cool mode or Dry Contact protection Voltage protection mode Customer Care Please Contact Customer Unit will run with Care Compressor OFF Fan mode Run IDU as per user settings 0x17 Compressor position Error 23 Compressor Cool mode or Dry Contact protection position protection mode Customer Care Please Contact Customer Unit will run with Care Compressor OFF Fan mode Run IDU as per user settings Ox1A Outdoor Condenser Error 26 Outdoor Cool mode or Dry Contact coil temperature Condenser coil mode Customer Care sensor error temperature error Unit will run with Please Contact Customer Compressor OFF Care Fan mode Run IDU as per user settings 23 48663967 Rev 1 Contents Gei TRANE Error Error Description Error Displayed on Unit Response Action to be codes Remote Taken by user Ox1E Outdoor temperature Error 30 Outdoor Cool mode or Dry Contact sensor error Temperature sensor mode Customer Care error Please Contact Unit will run with Customer Care Compressor OFF Fan mode Run IDU as per user settings Remote not in NETWORK NOT FOUND Unit operates as per Remote must be network range previous settings in network range EE Unit operates as per Contact service user did factory reset CONNEC
23. splay J Figure 16 2 4 2 10 Swing Control Deflector rod Figure 17 1 Use swing to adjust air flow direction The horizontal louver changes direction at defined angle and auto swing Vertical louver can only be adjusted manually Move deflector rod manually to adjust air flow direction 2 Adjust air flow direction properly otherwise it can cause discomfort or uneven room temperatures 2 4 2 11 Power ON and OFF 1 Press ON OFF button to switch ON OFF the unit When power is ON the unit operate in TRANE mode by default 2 Remote back light will glow in red 2 4 3 Replacement of Batteries Do not use combination of old and new batteries Life of battery is more than six months in normal usage To prevent batteries from leakage of electrolyte and damaging controller remove the batteries if not using for long duration Batteries are to be replaced when Low Battery error is shown on display To Replace Batteries Slide back cover and remove old batteries Use two new AAA alkaline batteries Recommended Duracell AAA batteries rated 1 5V Battery Poles must align with installation position Refer Figure 18 Registered trademark of Duracell P amp G Inc 17 48663967 Rev 1 Contents A CAUTION Risk of explosion if batteries are replaced by an incorrect type Dispose of used batteries according to the instructions provided on the batteries
24. t done it can cause electrical shock or fire 48663967 Rev 1 Contents Turn off the power supply and pull out power connection before cleaning If not done it can cause electrical shock e Chemical agents such as Gasoline benzene thinner insecticides etc can damage this unit Make sure installation stand is sufficiently firm An unstable stand can cause physical injury to the person damage or the unit Operate this unit with stable voltage in range of 230 10 single phase If not done compressor can vibrate and damage refrigeration system wire Use only fuse of correct capacity Incorrect wire can cause breakdown or fire Turn off the power supply If you detect burning smell or smoke turn off power supply and contact customer care centre immediately 48663967 Rev 1 Contents A CAUTION Don ts Do not try to repair this unit It can cause damage Do not block air intake or outlet vents of both outdoor and indoor units It can decrease the performance of the unit or cause malfunction Do not keep remote on any metals electronic or heating devices like oven TV etc for a longer period It may decrease the life of remote w Do not expose your body to cold air for a long duration It can cause deterioration in physical condition and health problems Do not use water at a temperature above 4
25. y E 25 3 48663967 Rev 1 Gei TRANE 1 About this manual This manual is given as a guide to good practice for operating and periodic maintenance of TRANE Air Conditioners This does not contain the full servicing procedures necessary for continued or successful operation of this equipment The services of a qualified service personnel must be employed through medium of maintenance contract with a TRANE service company Do not operate before reading manual s supplied with this product Cautions as applicable are shown in this manual Personal safety and proper operation of this unit require that you follow them carefully The manufacturer assumes no liability for installations or servicing performed by unauthorised personnel Always install operate inspect and maintain this product in accordance with all applicable standards and regulations local state country federal etc Keep this user manual carefully for future reference 4 48663967 Rev 1 Contents Gei TRANE 1 1 Safety Information A WARNING Indicates a potentially hazardous situation which if not avoided could result in serious injury A CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury or property damage Obey the following points to prevent electrical shock or fire A WARNING Don ts Do not remove power plug while the unit is in operation It can cause an el