Home
Excalibur® NSF Commercial Food Dehydrator 1 Zone
Contents
1. To delete a profile press the W recycle icon
2. Excalibur NSF Commercial Food Dehydrator 1 Zone User Manual America s Best Dehydrator 6083 Power Inn Road Sacramento CA 95824 916 381 4254 Fax 916 381 2566 www drying123 com Excalibur Leaders in the Field of Commercial Drying Technology IMPORTANT The Excalibur Commercial Dehydrator is an innovative state of the art dehydration unit equipped with a powerful Computer Controller Please take time to read this User Manual before you attempt to set the computer profiles There are several steps to setting the sophisticated controls and operating this unit N CAUTION or WARNING Failure to Follow the instructions EXACTLY as outlined in the User Manual will cause your Unit to not work properly or will cause your unit to not work at all Theory of Operation Unlike an oven which maintains heat at a constant temperature the Excalibur Commercial Dehydrator is a state of the art dehydration unit which utilizes the innovative technology of temperature cycling After you set the time temperature profile on the computer controller and when a profile is started the fans begin to run and the heating elements are switched on The fans will continue to run throughout the whole drying process until the profile is stopped The AIR temperature rises until the set point temperature you entered in the profile is reached When the set point is reached the heating ele
3. bur Digital Controller is backed by a one year warranty to the first purchaser for use providing that the units have not been misapplied This warranty does not apply to damage resulting from transportation alteration misuse or abuse Products sold through online auctions by unauthorized dealers or discount retailers are not eligible for warranty services from Excalibur To obtain warranty service an original or copy of the sales receipt from the original authorized retailer is required THEREFORE YOU SHOULD RETAIN YOUR SALES SLIP OR INVOICE If your commercial Dehydrator needs warranty service please contact our Technical Support Department In most cases technical problems can be corrected over the phone Tech support can be reached at one of the following numbers Tel 916 381 4254 Fax 916 381 4256 Terms and Limitations The company will repair or at its discretion replace the defective parts free of charge if in the judgment of the company it has been proved to be defective as to seller s labor and material within the warranty period New or rebuilt replacements for factory defective parts will be supplied for ninety days from date of purchase This warranty does not cover the cost of installing the parts Replacement parts are warranted for the remaining period of the original warranty Limitations The warranty is void if the product is used for any purpose other than which it is designed and has not been sub
4. jected to abuse negligence accident alteration or failure to follow operating instructions or the product has been exposed to abnormal or extreme conditions The product must not have been previously altered repaired or serviced by anyone other than factory service personnel The serial number must not have been altered or removed The product must not have been subjected to accident in transit or while in the customer s possession misused or operated contrary to the instructions contained in the instructions manual This includes failure caused by neglect of reasonable and necessary maintenance improper line voltage and acts of God This warranty is not transferable Except to the extent prohibited by applicable law no other warranties whether expressed or implied including warranty merchantability and fitness for a particular purpose shall apply to this product Under no circumstances shall Excalibur Products be liable for consequential damaged sustained in connection with said product and Excalibur Products neither assumes nor authorizes any representative or other person to assume for it any obligation or liability other than such as it expressly set forth herein Any applicable implied warranties are also limited to ninety day period of the limited warranty This warranty is subject to the Laws of the State of California and covers only the product and its specific parts not the food or other products processed in it Ope
5. ments will switch off The AIR temperature will continue to rise a few degrees due to residual heat in the unit This is normal and there is minimal effect on the internal food temperature by this rise in AIR temperature The heating elements remain off until the AIR temperature drops several degrees below the set point at which time the heating element will turn back on The temperature will again begin to rise to the set point of the profile This cycling is called Hyperwave and is an important part of the drying process It is important to remember the temperature shown on the controller is the temperature of the air at the back of the unit A temperature sensor can be used to check the internal temperature of the food product being dried if internal temperature is of concern CAUTION or WARNING All meat and poultry products should be heated to a minimum temperature of 160 165 F prior to the dehydration process to kill any bacteria that may be present Warranty Info Commercial Dehydrators 1 Year Limited Warranty Excalibur Products warrants to the ORIGINAL RETAIL PURCHASER of this product that if it is purchased through an AUTHORIZED EXCALIBUR RETAILER or Directly from the Factory and operated in accordance with the printed instruction accompanying it then for a period of 1 year from the date of purchase the product shall be free from defects in material and workmanship The Excali
6. nd Cycle The program is now running a First and Second Cycle time and temperature NOTE When a Second Cycle time and temperature is running a 1 appears in the furthest box to the right The 1 indicates that the program is running in its first cycle When the first cycle is complete the number will change from 1 to 2 When a Single Cycle time and temperature is running the box will display an S If a program is not entered the box will display an Step 5 Stop running or cancel a current cycle example From the Main Menu screen press the temperature icon or time icon Choose the stop icon to cancel the current cycle Note If no choice is made within 5 seconds the screen will revert to the Main Menu with no changes Saving and Naming a Program Step 1 Follow Steps 3 4 in the previous programming procedures After all cycle times and temperatures are set press the diskette icon from the Start Screen Step 2 Type the name of your profile on the keyboard screen Press the th check mark icon when profile is complete ha 0 ee HIJKLMN OPQRS T UVWXYZ 123456789 7 ores the Ml fi Icon The profile named will be saved on the screen as indicated by the arrow Use the arrow icons to select your programmed profile To initiate the selected profile and begin running the program F press the check icon
7. ration of the Unit The unit is equipped with a computer controller Programming Programming the controller is a systematic procedure The illustrated programming procedures on pages 4 7 are designed to direct the programmer to the next screen once a step is completed If at any time the step s listed in the programming instructions do not coincide with the illustrated display screen s return to the Main Menu Screen by pressing the X on the Home Page Screen Or for further assistance call 954 202 7419 ext 417 Note Programming the Controller Step 1 Load product into zone Step 2 Turn Power Switch to the ON Position After several seconds the Main Menu Screen appears step 3 Program the zone by pressing one of the OFF buttons from the Main Menu Screen Press B up or Ba down icon on the Home Page Screen to set time and temperature Press check mark icon when finished Step 4 Running the Program There are two choices Main Menu Screen Home Page Screen Add Start Screen Press the icon to begin running a Single Cycle time and temperature The screen will return to the Main Menu to display the program OR To add a Second Cycle time and temperature Press the J plus icon to program a Second Cycle time and temperature Repeat the programming procedures outlined in Step 3 Press the icon when finished programming the Seco
Download Pdf Manuals
Related Search
Related Contents
FILTRI 01 "ALLARME ROSSO" Pundit PL-200PE Mode d`emploi Semiconductor Test Laboratory Improvements for High Temperature Manual de instalação e do usuário TG-310 TG-610 Denon AVR-789 User's Manual HC-V500M Características del nuevo aire acondicionado SANit User Manual - Accusys : ExaSAN HP Compaq Pro 6300 MT Copyright © All rights reserved.
Failed to retrieve file