Home

BFC SERIES - ARPI Industrial Equipment

image

Contents

1. 6 TX Send Red LED RX Receive Green LED Turns on when communicates and inputs SW Parameter indication 4digit Red 7segment Indicates parameter and processes of communication instruction execution 3 Setting value indication 4digit Green 7segment Indicates setting value and process of communication instruction execution UP DOWN key To modify setting value MODE key To shift or select parameter when entering parameter setting mode PC loader port In case of PC communication use USB to Serial converter SCM US sold separately Side cover To connect an amplifier unit use a side connector accessory Remove the side cover to connect the amplifier unit 8 Connector cable port The terminal for attaching a connector cable accessory is used for RS485 communication or SW input No ol amp m Installations 1 DIN rail installations 1 Attachment lt Picture 1 gt DHang up the backside holder of the communication converter unit on DIN rail 2 Press the front part of the communication converter unit toward DIN rail 2 Detachment lt Picture 2 gt 1 Slide the back part of the communication converter unit as shown in figure 2 Lift up the communication converter unit as shown in figure 2 Communication converter unit BFC Series and Amplifier unit BF5 Series Connection Remove the side cover at the side of communication converter unit where amplifier unit will be connected commun
2. Autonics Digital Fiber Optic Amplifier Communication Converter BFC SERIES M A U A L 1 N 1 Nn OO A A WO N Thank you very much for selecting Autonics products For your safety please read the following before using Caution for your safety Please keep these instructions and review them before using this unit Please observe the cautions that follow A Warning Serious injury may result if instructions are not followed A Caution Product may be damaged or injury may result if instructions are not followed The following is an explanation of the symbols used in the operation manual A Caution Injury or danger may occur under special conditions In case of using this unit with machinery Nuclear power control medical equipment vehicle train airplane combustion apparatus entertainment or safety device etc it is required to install fail safe device or contact us for information required It may cause a fire human injury or property loss Do not disassemble or modify this unit Please contact us when required It may give an electric shock and cause a fire This unit shall not be used outdoors It might shorten the life cycle of the product or give an electric shock Use this product indoors only Do not use the product outdoors or at locations subject to the temperature or humidity of outdoors Example rain dirty frost sunlight condensation etc Do not use this unit where inf
3. 19200 38400bps w Parameter setting Communication standby key 3 sec UATE er 2 key 3 sec mode Communication parameter Prien Communication mode Coal 455 RS485 communication mode key Communication address Adr l key Communication speed bPS S key x2 Response waiting time mHE re A Parity bit Peed ola Stop bit nanE lashes twice moves to commu Response wating time Po r Standard Start bit Stop bit Parity bit Data bit Protocol nication mode setting QD key QZD key lt gt b at SW input mode QD key Serial communication mode QD key QD key lt Adr Adr D key lt gt ice bPS bPS QD key FZE QD Okey QD okey lt gt es EuEn PeeY QDokey SEaP key Q oke SeEaP ibi E ee EIA RS485 20 99ms 1 bit Fixed 1bit 2bit None Even Odd 8bit Fixed Modbus RTU apping communication address at the
4. same communication line Factory default Communication speed display X 2 Communication response waiting time range is 20 to 99ms Depending on the number of amplifier units connected response time may increase up to 350ms Error Code Description Solution _ _ E A Reading Writing errors occur while processing data inf Check the circuitry around EEPROM inside the EEPROM of amplifier unit product Slave fails to execute Master s group instructions such as Copy Load Save Teaching sent through communication line due to unstable communication line Other communication problems Solution methods for communication problems 1 Communication errors dur ing Serial or RS485 connections Check the connection status between communication unit and amplifier units Check the circuitry around the side connector and hardware condition Check if the communication mode selected in communication converter unit suits installation environment Check and equalize Check and equalize number set in DAQMaster 2 Communication errors dur ing SW signal input the address of communication converter unit and address set in DAQMaster the communication port of communication converter unit and the communication port Check if the communication mode set in communication converter unit is SW input mode SW Bank Check if the connections are made thoroughly depending on NPN or PNP input type w Caution f
5. change without notice m Specifications NPN Solid state input PNP Solid state input BFC P BFC N Power suppy E D BINDO 10 w Communication mode This communication converter unit supports 2 communication modes and SW input mode You can use only 1 mode of 3 modes 1 Serial communication 2 RS485 Connector cable 4 4P 2m AWG 22 Insulator diameter 1 25 side connector Current consumption Max 40mA LOW 0 1V HIGH 5 24V SW1 SWe2 HH Standby HL BANKO SW1 SW2 LL Standby LH BANKO LH BANK1 LL BANK2 HL BANK1 HH BANK2 SW input SW1 SW2 Communication function RS485 Communication Serial Communication SW input Communication speed 1200 2400 4800 9600 19200 38400bps e Parameter Red 4digit 7segment Setting value Green 4 digit 7 segment e Indicator TX indicator Red RX indicator Green e Real time monitoring incident light level on off state e Executes every BF5 feature and sets parameter by external device Master 10 to 50 Storage 20 to 60 C Ambient temperature Ambient humidity Environment 35 to 85 RH Storage 35 to 85 RH 1 5mm amplitude at frequency of 10 to 55Hz for 1 min in each of X Y Z directions for 2 hours 500m s 50G X Y Z directions for 3 times X 1 Powered by supply voltage of the amplifier unit connected by a side connector X Environment resistance is rated at no freezing or condensation w Parts description
6. e Humidity transducers W Switching power supplies E Stepping motors drivers motion controllers E Field network devices e Autonics Corporation http www autonics com Satisfiable Partner For Factory Automation MHEAD QUARTERS 41 5 Yongdang dong Yangsan si Gyeongnam 626 847 Korea MOVERSEAS SALES Bldg 402 3rd FL Bucheon Techno Park 193 Yakdae dong Wonmi gu Bucheon si Gyeonggi do 420 734 Korea TEL 82 32 610 2730 FAX 82 32 329 0728 HE mail sales autonics com The proposal of a product improvement Bank Load tt cHot i Sallis LoAd End 1 LoAd bARG ee acai 1905 4 CHO oHI gt LoAd End TEE 1 tt cH32 E i HEE c500 i000 1 Bank Save tt cHot tf aunt SAwWE End Rir i SAGE OAT gt cno LH ot gt SAuE End PE e500 gud ri glee fi e580 1000 E i Bank Copy lai PHO 5 p i mio 1 c J ie w Pe CoPY ALL H cu z ek tL ot gt CoP YL Eng i i F oc ae i to H tt CH32 i Led oe 4 ETT tT AL End i PCHO tN oe TE LAAL O gt cHo2 gt LJAL End 0 5 sec twice flash 2 L AL E nd choc ob Pte AL End PCHI2 ot Bank Save All icon ROEF E ane i I tot UPL m ity bret oc i SuAL bAED rl cHo2 AT Te SuAL End i 0 5 sec twice flash ASIS nd rt LHuc ob pee SuAL End i CHIE ot Teaching All i cHoi lt are os EH ALL oie ELH ELCHI End in CHO ov ec
7. ication converter 3 After attaching the communication converter unit and the amplifier unit to the DIN rail push gently to have both units fastened into each other Improper connection may cause malfunction Do not supply the power while connecting or disconnecting converter unit BFC Series 3 Connector cable attachment and detachment 1 Attachment lt Picture 3 gt Insert the connector cable into the installed communication converter unit on DIN rail until it clicks 2 Detachment lt Picture 4 gt Pull out the connector cable with pressing the connector cable lever downside 4 USB to Serial converter SCM US attachment and detachment Connect the USB to Serial converter SCM US sold separately to PC loader port 1 Serial communication 2 RS485 communication Following is a screen of DAQMaster properties window of a computer connected communication converter unit a SCM US48I SCM 38I1 Compute Orange A Amplifier unit BF5 Series ACaution g 5 e inc Lo on a 4 fOr T A Vcc A n TN i PNP type T j Connector i cable N f s TTT k 3 SW input l Communication converter unit BFC Series NPN type unit BFC It may cause damage the product Connect the USB to Serial converter SCM US sold separately to the PC loader port for communicating with PC lt is very easy to manage parameters and monitor data of connec
8. lammable or explosive gas exists It may cause a fire or explosion Please observe the rated specifications It may damage or shorten the life cycle of the product Do not use this unit beyond rated power and do not supply AC power to a DC power type product It may cause a damage to the product Please check the polarity of power and wrong wiring It may cause a damage to the product Do not use this unit where there is vibration or a chance of impact It may cause a damage to the product When cleaning the unit do not use water or an oil based detergent It may cause a fire give an electric shock or damage to the product m Proper usage Before using this communication converter unit depending on the usage environment keep following items handy Visit our web site www autonics com to download 1 2 3 4 4 DAQMaster program Integrated device management program User Manual SCM US Driver USB driver Serial port driver Manual SCM US48I Driver USB driver Serial port driver Manual SCM 38I Manual Communication converter unit BFC User Manual For Communication w Dimensions e Accessories lt Connector cable gt 36 5 70 EPR lt RS485 gt Orange Serial Com Phone Jack Phone Jack Side Side Connector b gt O c c o S 12 24VDC 12 24VDC G lt SW Input gt External x The above specifications are subject to
9. m End i ti CHI i ECH End iCHoe Be ees 3 I 1 ECHI see ECA toa CHJ oF i Initialize i font a eae S a aaa CHOI otlane End be eee Mt e500 i000 T eee eer eres CH32 2500 dad Data Bank See Setting value of data bank Bank 0 Bank 1 Bank 2 can be saved and development product autonics com EP KE 7 7 0022 E Laser marking system COz Nd YAG E Laser welding soldering system
10. or using 1 In case power in supplied from a switching power supply ensure that the frame ground F G terminal of the power supply is connected to an actual ground and connect a condenser between OV and F G terminal for noise removal Avoid using the unit where dust exists or corrosion causing environments It may cause product malfunction Do not start operating during initial power supplying time 3 sec In case moving the unit from cold outside to a indoor room start operating after removing moisture Do not wire high voltage power source line and unit together It may cause product damage or malfunction due to noise Do not use the unit outdoor or anywhere exposed to direct extraneous light In case of max sensitivity setting there might exist slight sensing distance difference due to each feature deviation Please note that this unit Installation environment 1 It shall be used indoor 3 Pollution Degree 3 is non isolated 2 Altitude Max 2 000m 4 Installation Category II x It may cause malfunction if above instructions are not followed m Major products E Proximity sensors E Area sensors E Photoelectric sensors E Fiber optic sensors E Door Door side sensors E Sensor controllers E Graphic Logic panels E Temperature controllers E Counters E Timers E Display units E Panel meters E Pressure sensors E Rotary encoders E Power controllers E Tachometer Pulse Rate meters E Temperatur
11. plying signals to SW1 Black and SW2 White of the connector cables which is connected to the communi allows change of banks as shown in chart 1 SW input signal duration shou seconds Chart1 Bank selection table based on SW input allows amplifier unit cation converter unit Id be longer than 3 Ns alte Indications appear on communication converter and amplifier units depending on applied instruction are shown below SW input standby state SEE bAKD At the standby state as shown above display indicates the current bank in use Communication converter unit received SW input signal instructions Amplifier unit executing Communication converter unit after amplifier unit executes instructions x bAHD bAE I I 1 I 1 i i i i 1 i i i I 1 i i 1 i i I i i i I 1 i lt Communication Specification gt Standard Maximum connections Communication method Synchronization metho Effective communication distance Communication speed X It is not allowed to set over Xx Please use a proper twist pair for RS485 communication EIA RS485 31 Address setting 01 99 2 wire half duplex d Asynchronous 1200 2400 4800 9600
12. te YA This indicates the waiting state for instructions while preserving master unit PC PLC and communication converter unit real time data transfer incident light level of the amplifier unit Communication converter unit recived an instruction from DAQMaster Communication converter unit after amplifier unit executes instructions Amplifier unit executing instructions Do not connect a powered BF5 connector cable to a communication converter 3 SW input SW input is a feature which connected with the communication converter unit to load all banks Ap
13. ted amplifier units BF5 Series using the integrated management program DAQMaster free Refer to DAQMaster and amplifier unit manuals e PLC connection Connect directly to a PLC using RS485 communication cable of the communication converter unit Amplifier units BF5 Series can be controlled through PLC Refer to communication converter unit BFC communication manual e PC connection Connect PC using Communication converter SCM 381 or SCM US48l sold separately Refer to Communication converter SCM series manual Same as 1 Serial Communication information line xj Config Indicates the number of amplifier units connected to the communication converter unit BFC Status Indicates the information of the selected amplifier unit Dual Single by channel connected to communication converter unit BFC 3 Program group Setting values of the amplifier unit can be changed When setting values of the amplifier unit changed TX Red and RX Green LEDs on communication converter unit will flash indicating application of setting values to the amplifier unit Property BF5 Series gt gt 1 General Data Bank Group Bank 0 Bank 1 Bank 2 Data Bank Group Data bank and group teaching features of amplifier unit can be set Amplifier unit can be initialized as well xX Indications appear on communication converter and amplifier units depending on applied instruction are shown below Communication waiting sta