1. A minimum of one layer of 5 8 inch drywall taped with minimum one coat of approved joint compound The floor ceiling assembly shall be draftstopped per R502 12 2 Installation of an approved automatic fire sprinkler system in R504 Deleted with all subsection in their entirety Pressure Prohibits wood basement floor preseratively construction treated wood floors on 2006 Code Amendments Page 18 2006 CODE AMENDMENTS H OD IRC R506 1 Replaced 3 5 inches with 4 inches and added the following Concrete floors Re establishes current Village sentences Provide a minimum of 6x6x10x10 welded wire fabric on ground of Sugar Grove requirement of embedded in the mid cross section of all slabs subjected to 4 thick slabs and clarifies vehicular loading Fiber reinforcing can be used in place of welded when and what type of wire The contractor shall supply copies of all the load tickets for all reinforcing is required as a the fiber reinforced concrete placed for approval minimum IRC R506 2 1 Added subsection R506 2 1 1 Back Fill under Concrete Floors at Changed requirements to Attached Garages The sub base for poured concrete garage floors Preparation match current Village of Sugar shall be undisturbed inorganic soil All fill material shall be clean Grove code amendments compactable graded sand crushed stones or gravel placed in compacted lifts R506 2 2 Replaced consisting of clean with consisting of co
2. IFC 902 1 Replaced first sentence Furnaces water heaters and boilers Definitions Safety of Inhabitants unless specifically required by the manufacturer shall be connected to the gas piping system by only rigid metallic pipe and fittings Appliances except for furnaces wa 2006 Code Amendments Page 23
3. Adds back in the code Single or combined mechanical exhaust systems from bath toilet Systems requirement for separate urinal locker service sink closets and similar rooms shall be exhaust to toilet rooms that was independent of all other exhaust systems removed from this code version IEC Deleted entire exception i Deletes exception so it now requires submittal of ASHRAE compliance forms even if 2006 Code Amendments Page 3 2006 CODE AMENDMENTS BOOK SECTION RECOMMENDED CODE CHANGE CONTEXT OF REASON FOR CODE CHANGE OD 602 2 1 Added Sentence Nonmetallic ducts shall not be used in a non Materials Clarifies the type of duct combustible plenum Exception 1 is amended by replacing with Exposed within material allowed in plenums Rigid and flexible metallic ducts and connectors shall conform to Plenums Section 603 603 6 2 1 Replaced with Flexible air connectors shall be limited in length to Connector Reduces allowable flexible duct ten feet 8048 mm Length lengths from 14 ft to 10 ft 603 1 Added sentence All duct work or mechanical equipment shall be Supports Requires code required duct supported or fastened directly to the structural supports of the hangers to be attached to building Mechanical equipment and duct work shall not be hung building structure from the roof or floor deck above or other ductwork or piping prevent the operation of the appliance when the power exhauster is power exhauster is not no
4. FEMA requirements Construction may need to be met for construction in a flood hazard 1801 Added subsection Section 1801 3 Continuous Foundations General Requires habitable buildings to Buildings and structures and the walls enclosing habitable or have continuous foundations occupiable rooms shall be provided with a continuous foundation Was a previous amendment for residential now commercial also 1805 4 5 Deleted entirely i Re establishes current Village i of Sugar Grove code amendment that does not allow wood footings and foundations 1805 4 6 Deleted entirely Re establishes current Village i of Sugar Grove code amendment that does not allow wood footings and foundations Pi 11 4 Replaced of preservative treated wood with prohibited i Re establishes current Village contact with of Sugar Grove code the ground amendment that does not allow wood footings and foundations 2006 Code Amendments Page 12 2006 CODE AMENDMENTS H OD code for jurisdiction R202 Replaced the definition for Accessory Structure Definitions Changed definition to match rd a Village of Sugar Grove s Zoning Ordinance Replaced the definition for Manufactured Home State definition pee ee the definition for Modular Home definition R301 2 1 Amended Climatic amp Geographic Design Criteria Table Climatic and To reference our Geographic Geographic location design criteria R301 2 4 Added Applicable Kane Co Stormwater Ordinance
5. at Designated Pick Rubbish and _ Restriction on putting out Up Area Rubbish garbage garbage cans and or recycling Garbage bringing in garbage receptacles containers shall be placed out on the designated pick up area no to keep trash from earlier than 3 00 p m 1500 hours the day before pick up Cans accumulating and remaining in and containers shall be removed from the designated pick up area the right of way especially on no later than 8 00 p m 2000 hours the day of pick up move outs IPMC 404 4 4 Replaced with Kitchens closets and storage rooms utility rooms Prohibited Clarifies sleeping room laundry rooms dens hallways stairs bathrooms and toilet rooms Occupancy occupancy definition garages accessory buildings crawl spaces attics uninhabitable spaces interior public areas and rooms not designed or intended as sleeping rooms or bedrooms shall not be occupied for sleeping DULDOSe IPMC 404 4 5 Replaced with and the fire safety requirements of Chapter 7 Other bedroom Makes rooms meet all Chapter and living room 7 requirements not just limited requirements jones IPMC 602 3 Inserted September 1 and May 1 Heat Supply __ Setting dates for heat supply in dwelling units Work Spaces __ supply in work spaces IPMC 702 3 1 Added sentence Doors providing access to a sleeping roomina Locked doors Added requirements for dwelling unit shall not have any locks padlocks hasps or other sleeping ro
6. buildings inspection Before permit issuance a statement of special inspections prepared by the registered design professional shall be submitted detailing the individuals and approved agencies intended to be retained for conducting these inspections This report and signed certification shall be submitted to the Village before any occupancy will be granted R802 3 1 Added Where ceiling joists are not connected to the rafter at the Ceiling joint Adds back in the code the top wall plate rafters shall be connected to wall plates by use of and rafter requirement for connectors at approved connectors having a resistance to uplift of no less than connections _ tray and cathedral ceiliings that 175 pounds and shall be installed in accordance with the was removed from this code manufacturer s specifications edition R802 10 1 Added to item number 4 1 including snow load and added a new Wood trusses Requires truss placement plans item 13 Truss placement diagram layout design along with the individual truss certs R903 Added subsection R903 6 Gutters and Downspouts All one and Gutters and Requires gutters and two family dwellings shall be provided with gutter and downspouts Downspouts downspouts to convey water unless omission is specifically permitted by the Code Official away from the foundation wall Grove code amendments N1101 2 Deleted the first sentence and replaced with Compliance shall be Energy Clarif
7. of any material required to allow inspection Replaced board of appeals with Village Board of the Village of Administration jclarification establishing Board Sugar Grove of Appeals Added subsection Section 407 2 1 Structural Attachment All fuel Structural Clarifies where the code gas piping shall be supported or fastened directly to the structural Support required hangers brackets etc supports of the building Fuel gas piping shall not be hung from the can be attached to the building roof or floor deck above or other ductwork or piping 2006 Code Amendments Page 1 2006 CODE AMENDMENTS BOOK SECTION RECOMMENDED CODE CHANGE CONTEXT OF REASON FOR CODE CHANGE OD IFGC 411 1 Replaced Except as required by Section 411 1 1 appliances shall Connecting Requires rigid connections to be connected to the piping system by one of the following with Appliances equipment that is permanently Furnaces water heaters and boilers unless specifically required installed and would not need to by the manufacturer shall be connected to the gas piping system by be moved Allows flex at only rigid metallic pipe and fittings Appliances except for furnaces stoves dryers etc only water heaters boilers and as required by section 411 1 1 shall be connected to the gas piping system by one of the following IFGC Appendice Adopted amp Inserted Appendices These appendices are s A B C amp regarding gas inf
8. requirements Floodplain Lists other requirements that FEMA or Village flood plain ordinance Construction may need to be met for construction in a flood hazard Grove code amendments R309 1 Added Provide surface mounted closer or self closing hinges Opening Changed requirements to Glass is not permitted in the doors Protection match current Village of Sugar R309 2 Replaced all references to 1 2 inch gypsum board with 5 8 inch Separation Changed requirements to Type X gypsum board and added All code required 5 8 inch Type Required match current Village of Sugar X gypsum at garage interior shall be taped with a minimum of one Grove code amendments coat of approved joint compound Replaced 3 feet with 10 feet Grove code amendments R309 3 Added garage gas curb and stairwell in garage Floor Surface Changed requirements to match current Village of Sugar IBC RC RC RC RC IRC IRC IRC IRC IRC basement Escape and match current Village of Sugar Rescue Grove code amendments R310 Added sill height maximum above floor for egress windows in Emergency Changed requirements to 2006 Code Amendments Page 13 2006 CODE AMENDMENTS H OD IRC R310 2 1 Replaced 44 inches with 36 inches for the minimum height Ladder and Changed requirements to requirement for a ladder or stps inside a window well Steps match current Village of Sugar Grove code amendments IRC R311 2 2 Added 5 8 type X gypsu
9. to buildings without footings foundations down below frost line Deleted entirely Pier and Changed requirements to curtain wall match current Village of Sugar foundations Grove code amendments Added Subsection R404 1 9 Foundations at Additions All Foundations at Adds to or alters language of foundations at additions shall be anchored to existing foundation iti code to match standard local walls with imbedded grouted dowels or other approved methods construction procedures and current Village of Sugar Grove policies Deleted all subsections and related tables in their entirety Wood Re establishes the current foundations shall be prohibited i Village of Sugar Grove code amendment that does not allow wood footings or foundations Deleted all subsections and related tables in their entirety Wood Re establishes the current foundations shall be prohibited Foundations Village of Sugar Grove code amendment that does not allow wood footings or foundations Deleted all subsections and related tables in their entirety Wood Damp proofing Re establishes the current foundations shall be prohibited for wood Village of Sugar Grove code foundations amendment that does not allow wood footings or foundations 2006 Code Amendments Page 17 2006 CODE AMENDMENTS BOOK SECTION RECOMMENDED CODE CHANGE CONTEXT OF REASON FOR CODE CHANGE A OD Replaced with Posts poles and columns supporting structures Wood column Requires structural
10. wood posts shall not be embedded in concrete that is in direct contact with the protection to be elevated on concrete earth or exposed to the weather helps with rotting makes replacement easier R408 Added Subsection R408 8 Crawl Space Floor Slab In all crawl Crawl space Changed requirements to space areas a minimum of two 2 inch thick slush coat of poured _ floor slab match current Village of Sugar concrete shall be installed over a minimum of a six 6 mil thick Grove code amendments polyethylene film moisture barrier with all joints lapped a minimum of six 6 inches over a minimum of four 4 inch stone inch supports increases minimum size of DHOOM O IRC R502 11 4 Added to item number 4 1 including snow load and added a new Truss Design Requires truss placment plans item number 13 Truss placement diagram layout design Drawings along with the individual truss certs R502 7 Deleted exceeding a nominal 2 inches by 12 inches 51mm by Lateral Requires bridging at all floor 305mm and replaced 1 inch by 3 inch with nominal 2 inch by 4 _ Restraints at joists not just over 2x12 s and R502 Added subsection R502 14 Protection of Wood I Joists and Protection of Changed requirements to Trusses All prefabricated wood I joists and or wood trusses used wood I joists match current Village of Sugar in a floor ceiling assembly shall be protected by one of the and trusses Grove code amendments following 1
11. 2006 CODE AMENDMENTS BOOK SECTION RECOMMENDED CODE CHANGE CONTEXT OF REASON FOR CODE CHANGE A OD Replaced with The Code Official is authorized to conduct such Evaluation and Amends the code to allow for inspections as are deemed necessary to determine compliance with follow up concealment of wiring and the provisions of this code Construction or work for which a permit jinspection piping in state approved is required shall be subject to inspection by the code official The services prefabricated construction only approval of a prefabricated construction assembly in modular and requires all other wiring housing and mobile structures having concealed electrical work and piping to remain exposed shall comply with applicable State of Illinois regulations All other to allow for proper inspections construction or work shall remain accessible and exposed for inspection purposes until approved Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of this code or of other ordinances of the jurisdiction Inspections presuming to give authority to violate or cancel the provisions of this code or of other ordinances of the jurisdiction shall not be valid It shall be the duty of the permit applicant to cause the work to remain accessible and exposed for inspection purposes Neither the Code Official nor the jurisdiction shall be liable for expenses entailed in the removal or replacement
12. cable provisions of Chapters 26 thru 32 inclusive the International Plumbing Code State of Illinois Plumbing Code and all Village of Sugar Grove amendments to the International Plumbing Code and State of Illinois Plumbing Code P2603 6 1 Replaced with Building sewers that connect to private sewage disposal systems shall be under the jurisdiction of Kane County Health Department All other building sewers shall be as specified in Village of Sugar Grove ordinance Inserted twelve 12 inches E3301 1 Replaced with The installation of all electrical appliances equipment and systems in one and two family dwellings and swimming pools shall comply with the applicable provisions of Chapters 33 thru 41 inclusive the International Code Council Electrical Code National Electrical Code and all Village of Sugar Grove amendments to the International Code Council Electrical Code Appendice Adopted and inserted Plumbing Compliance Sewer Depth Clarifies all requirements to be met for residential plumbing installations Village doesn t have jurisdiction over septic systems Roof Extension Clarifies the minimum height Electrical Compliance Appendices above roofs that open pipe vents must extend to match Illinois Plumbing Code PO emne Clarifies all requirements to be met for residential electrical installations A B C D N and Q are informative only E is the requirements for manufactured mobile homes and F
13. ced the Internations Building Code with the International Requires a light to be on the Building Code or International Residential Code same circuit as the smoke detectors in residential and commercial so problems with the circuit dropped breaker etc are detected by the ICCEC 1202 Added subsection Section 1202 17 Unused Wiring All wiring Unused wiring Requires removal of fittings and electrical materials not in use shall be removed eee 2006 Code Amendments Page 8 2006 CODE AMENDMENTS BOOK SECTION RECOMMENDED CODE CHANGE CONTEXT OF REASON FOR CODE CHANGE OD ICCEC 1202 Added subsection Section 1202 18 Ground Fault Circuit Extends GFCI protection in Interrupter Protection for Personnel in Other Than Dwelling Units commercial buildings to the In addition to the locations required by 2005 National Electric Code same areas that require it in all 125 volt single phase 15 and 20 ampere receptacles installed residential uses in the locations specified below in other than dwelling units shall have ground fault circuit interruption protection for personnel ICCEC 1202 Added subsection Section 1202 19 Island Counter Spaces At Island counter Adds the requirement for an least one receptacle outlet shall be installed at each end of an spaces additional receptacle beyond island counter space the one currently required in ICCEC 1202 Added subsection 1202 20 Receptacles for Garage Door Receptacles Requires th
14. ch 1 diameter drain line that discharges into a floor drain or the nearest convenient drain A pan shall not be required when the washing machine and or water heater is located on the basement floor or concrete slab and there is a floor drain located in the immediate vicinity Table deleted and replaced with attached Added sentence Water service pipe shall be of such diameter as specified in Village of Sugar Grove ordinance and in accordance with AWWA publication M 22 entitled Water Service Lines and Meters Service line diameter is dependent upon peak water demand and meter distance from main Minimum service diameter shall be one inch 1 Table replaced with the attached 2006 Code Amendments Drain Pans can be attached to the building Addition of requirement for drain pans located under clothes washers located upstairs to keep spills from damaging wood floor structures similar to those already required by code at water heaters and water storage Eliminate other options for types of water supply pipes to match only those allowed by other Village of Sugar Grove OTOINANCE Matches the language in other Village of Sugar Grove ordinances regarding water service pipe requirements Modifies the table to only allow metallic water piping to continue current Village amendments not allowing Page 6 2006 CODE AMENDMENTS BOOK SECTION RECOMMENDED CODE CHANGE CONTEXT OF REASON FOR CODE CHANGE OD 605 5 Tab
15. e installation of a Openers A minimum of one overhead receptacle shall be installed for garage door receptacle in the garage ceiling for each garage door in any residential dwelling unit in addition to openers where homeowners are likely to the code required convenience receptacle add garage door openers ICCEC 1202 Added subsection Section 1202 21 Light at Sump When a sump Light atsump Provides light at pumps in pump or ejector pump is installed in an area not illuminated a light basement that may need shall be provided service ICCEC 1202 Added subsection Section 1202 22 Ceiling Box Support All Ceiling box Requires the installation of ceiling mounted lighting outlet boxes installed more than three feet support boxes capable of supporting from all walls of any room in a dwelling unit shall be listed and shall fans in the center of rooms be marked by the manufacturer as suitable for sole support of a where homeowers are likely to ceiling suspended paddle fan and shall be secured according to install them the listing directions The marking shall include the maximum weight to be supported Dwelling garages basements closets and bathrooms are excluded 2006 Code Amendments Page 9 2006 CODE AMENDMENTS BOOK SECTION RECOMMENDED CODE CHANGE CONTEXT OF REASON FOR CODE CHANGE A OD ICCEC 1202 Added subsection Section 1202 23 Tenant Access Each tenant Tenant Access Clarifies the code requirements shall have direc
16. eath the center line of the foundation wall for the entire code to match standard local length of the wall When reinforcing steel is a structural component construction procedures and of the intersection of the footings and foundation the keyway may current Village of Sugar Grove O R403 1 4 1 Exception number 3 is entirely deleted and replaced with Decks not Adds language to the code for supported by a dwelling and or not serving as a portion of the what has been Village of Sugar be omitted policies construction procedures and current Village of Sugar Grove R403 1 6 Added Gaps between sill plates and foundations shall be sealed Foundation Adds to or alters language of with mortar sill sealer or similar approved material Anchorage code to match standard local policies walls up to 24 inches in length R403 1 6 Deleted exception numbers 2 and 3 Foundation Eliminates two exceptions that Anchorage would allow no anchor bolts in 2006 Code Amendments Page 16 2006 CODE AMENDMENTS BOOK SECTION RECOMMENDED CODE CHANGE CONTEXT OF REASON FOR CODE CHANGE OD Deleted Wood foundations shall be prohibited Footings for Re establishes the current wood Village of Sugar Grove code foundations amendment that does not allow wood footings or foundations Added Frost protected shallow foundations shall be allowed only Frost protected Requires code official approval with specific permission of the Code Official shallow
17. ies all requirements to be demonstrated by meeting the requirements of the International Efficiency met for residential energy R1003 9 Added All wood or solid fuel burning appliances and stoves shall be Chimney Changed requirements to equipped with an approved labeled spark arrestor inati match current Village of Sugar Energy Conservation Code all Village of Sugar Grove amendments efficiency to the International Energy Conservation Code and the requirements of this chapter 2006 Code Amendments Page 20 2006 CODE AMENDMENTS BOOK SECTION RECOMMENDED CODE CHANGE CONTEXT OF REASON FOR CODE CHANGE OD M1 201 Added subsection M1201 3 Compliance The installation of all Mechanical Clarifies all requirements to be mechanical appliances systems and equipment in one andtwo Compliance met for residential mechanical family dwellings shall comply with the applicable provisions of installations Chapters 12 thru Chapter 23 inclusive the International Mechanical Code and all Village of Sugar Grove amendments to the International Mechanical Code M1305 1 Added subsection M1305 1 5 Prohibited locations Appliances Prohibited Prohibits furnaces and boilers designed to condition habitable spaces of a one or two family Locations in garages of one and two dwelling shall not be located in a garage except if elevated in family dwellings accordance with Section M1307 3 and installed in a dedicated enclosure in which all combustion ai
18. illage of Sugar Grove code amendments 2006 CODE AMENDMENTS BOOK SECTION RECOMMENDED CODE CHANGE CONTEXT OF REASON FOR CODE CHANGE H OD Added Site addresses shall comply with all Village of Sugar Grove Premises Refers to Village of Sugar ordinances Identification Grove code for specific requirements in addition to DULOING COAC Added and any applicable Kane County storm water ordinance Flood Lists other requirement that FEMA or Village of Sugar Grove flood plain ordinance Resistant may need to be met for requirements Construction construction in a flood hazard i Entirely deleted all references to wood foundations including any Application of Re establishes the current exceptions Wood foundations shall be prohibited Provisions Village of Sugar Grove code amendment that does not allow wood footings or foundations wood footings or foundations R403 Entirely deleted all references to wood foundations including Figures Footings Re establishes the current R403 1 2 and R403 1 3 Wood foundations shall be prohibited Village of Sugar Grove code amendment that does not allow wood footings or foundations footings are acceptable The accessory structure shall be Grove policy anchored to the foundation system IRC R402 1 Entirely deleted section Wood foundations shall be prohibited Wood Re establishes the current Foundations Village of Sugar Grove code amendment that does not allow R403 1 Added A
19. is radon control IRC Apendix G Added to section AG103 1 A four foot wide unobstructed area shall Swimming Requires room aound a pool to be provided around a minimum of three sides of the pool pools spas allow for proper rescue and hot tubs 2006 Code Amendments Page 22 2006 CODE AMENDMENTS BOOK SECTION RECOMMENDED CODE CHANGE CONTEXT OF REASON FOR CODE CHANGE A OD IFC 507 4 Inserted Lightweight Construction Buildings erected using Hazards to Fire Safety of Fire Fighters lightweight construction systems to include wooden I beams wood Fighters trusses metal trusses or any combination thereof shall identify the structural system used on the exterior of the building Signage shall be as listed in Section 507 4 1 of this code IFC 504 4 1 Inserted Emblem required An all weather emblem identifying Hazards to Fire Safety of Fire Fighters lightweight construction shall be provided located and designed as Fighters follows 1 Emblem shall be provided by the property owner 2 Emblem shall be located within 6 of the fire department key box not to exceed 6 feet above the ground 3 The emblem shall be of a bright and reflective color or made or reflective material The shape of the emblem shall be the shape of a triangle measuring 8 inches vertically by 8 inches horizontally 4 The following letters of a size and color to make them conspicuous shall be printed on the emblem as shown in the diagram attached
20. le replaced with the attached Pipe Fittings Modifies the table to only allow metallic water piping to continue current Village amendments not allowing plastic ninina 709 1 Table added to with the attached Made the required trap size in the chart match Illinois Plumbing Code requirements 904 1 Inserted twelve 12 inches Roof Extension Clarifies the minimum height above roofs that open pipe vents must extend to match Illinois Plumbing Code J ed emenn Deleted all subsections in their entirety Air Admittance Illinois Plumbing Code does not allow the use of air admittance valves erases sentence All sump pump discharge lines shall be bedded in minimum two inches Piping bedding of buried pipe T Adopted and inserted Appendices Appendix B clarifies the rainfall rates shown in map figure 1106 1 for certain cities Appendix D lists degreee days and design temperatures for cities Appendix F reiterates the limits on notching and boring holes for piping required in other volumes of the code construction the other code books language documents and our actual procedure ICCEC 502 2 Replaced Reviewed for Code Compliance with APPROVED Approval of Changed to be consistent with 2006 Code Amendments Page 7 2006 CODE AMENDMENTS BOOK SECTION RECOMMENDED CODE CHANGE CONTEXT OF REASON FOR CODE CHANGE A OD ICCEC 801 Subsection added Section 801 4 Electrical Service Attachments Service utilities Clarifie
21. ll accessory structures over 200 square feet shall have a__ Footings Adds language to the code for foundation system piers and or monolithic slabs with integral what has been Village of Sugar 2006 Code Amendments Page 15 2006 CODE AMENDMENTS H OD R403 1 1 Added The footing width W shall be at least twice the width of the Footings Adds to or alters language of foundation wall being supported And replaced Spread footings minimum size code to match standard local shall be at least 6 inches 152 mm thick with Spread footings shall construction procedures and be at least as thick as the width of the foundation wall being current Village of Sugar Grove supported And replaced Footing projections P shall be at least 2 policies inches 51mm with Footing projections P shall be at least one half the width of the foundation wall being supported loads supported and for soil conditions Isolated plain concrete R403 1 1 Added subsection R403 1 1 1 Isolated Footings Isolated concrete lsolated Clarifies minimum requirements footings for columns or pedestals shall be properly sized for all Footings for isolated footings footings shall be a minimum of 12 thick and shall be protected from required egress to grade need not be provided with footings that Grove policy extend below the frost line R403 1 5 Added A keyway shall be provided in the top of the footing Adds to or alters language of undern
22. m board taped with a minimum of one coat Under Stair Increased fire resistance of approved joint compound Protection required at enclosed storage under stairs IRC R311 4 Added requirement for 2nd exit door for egress at grade Changed requirements to match current Village of Sugar Grove code amendments Act 425ILCS60 Detection and R313 Added Carbon Monoxide Alarm Detector requirement per the Illinois Carbon Incorporate State of Illinois Act r Carbon Monoxide Alarm Detector Act Public Act 094 0741 Monoxide en Alarm R317 1 Increased the fire resistance rating from 1 to 2 hours on a two family Two Family Changed requirements to dwelling except where an automatic sprinkler system is installed match current Village of Sugar Also sets requirement for 1 2 inch gypsum board on the ceiling Grove code amendments ground wood footings and foundations R319 1 4 Eliminated the use of wood supports embedded in concrete that Wood Columns Re establishes current code come in contact with the earth amendment that does not allow wood footings and foundations 2006 Code Amendments Page 14 R319 1 2 Eliminated the use of wood construction for supports for permanent Ground Re establishes current code structures for human occupancy that come in contact with the amendment that does not allow IRC R317 2 Added requirement for mold resistant gypsum board to be used in Townhouses_ Changed requirements to fire resistance rated wall assemblies match current V
23. m shall be provided Where Re establishes the threshold throughout all buildings or structures where a fire area of any use or required for fire sprinklers at 5 000 Deleted number 4 in its entirety Exempt Deletes the exemption that Locations would allow non combustible rooms with wholly non combustible contents from being sprinklered Replaced exception 1 with Exit signs are not required in rooms or Requires exit signs in rooms areas where only one exit or exit access are provided and it is i that only require one exit if obviously and clearly identifiable as the exit that exit is not clearly Adding to number 3 when approved by the Fire Code Official Exempt Requires Fire Code Official Locations approval to not sprinkler rooms with generations or 2006 Code Amendments Page 11 2006 CODE AMENDMENTS RECOMMENDED CODE CHANGE REASON FOR CODE CHANGE OD 1608 Added subsection Section 1608 3 Snow Load Minimum All Snow Loads Clarifies which design snow structural designs in the Village of Sugar Grove shall meet or load to use since the Village of exceed a 25 pound ground snow load minimum with no reductions Sugar Grove sits near the border of 2 zones on the map pe ye 2 3 Inserted the Village of Sugar Grove and most recent Establishment Fills in blanks regarding flood of Flood hazard information Hazard Areas Added and any applicable Kane County Storm Water Ordinance or Design and Lists other requirements that
24. mpacted clean pee fee requirement to compact the courses of fill IRC R506 2 4 Replaced reinforcement with wire mesh or woven wire fabric Reinforcement Allows contractors to submit reinforcement and added Exception Contractor shall provide support letters of intent to comply with letter of intent indicating they will ensure proper placement of new code requirement reinforcement regarding placement of reinforcement R602 2 Replaced No 3 standard with No 2 standard Raises minimum grade for framing studs IRC R703 9 Replaced with All Exterior Insulation Finish Systems EIFS EIFS General Changed requirements to installed on any portion of a one and two family dwelling or match current Village of Sugar accessory structure shall be installed only on masonry or metal Grove code amendments substructure components EIFS shall not be installed over next to or in contact with wood materials 2006 Code Amendments Page 19 2006 CODE AMENDMENTS BOOK SECTION RECOMMENDED CODE CHANGE CONTEXT OF REASON FOR CODE CHANGE H OD R703 9 Added subsection R703 9 3 EIFS Special Inspections Any and all EIFS Special Requires special inspections of exterior insulation finish system EIFS installed on any portion ofa inspections EIFS at one and two family one or two family dwelling for an exterior covering requires a dwellings like IBC requires for certification or proper installation be submitted as a special all other
25. ndent of roof or floor deck piping or ductwork drywall or ceiling tile Lighting fixtures in ceiling grid systems shall be supported in accordance to manufacturer s requirements ICCEC 1202 Added subsection Section 1202 27 Non Metallic Boxes The use Non metallic Continues the existing Village of non metallic boxes is prohibited except for low voltage boxes ordinance prohibiting non applications metallic boxes 2006 Code Amendments Page 10 2006 CODE AMENDMENTS OD ICCEC 1202 Added subsection Section 1202 28 Concealed Knob and Tube Concealed Continues the existing Village Wiring The use of concealed knob and tube wiring is prohibited knob and tube ordinance prohibiting knob and Existing installations shall not require removal alteration or tube wiring abandonment of nor prevent the continued utilization and maintenance of properly maintained knob and tube wiring lawfully in existence at the time of the adoption of this code Such installations may only be repaired and shall not be expanded occupancy classification or combination of uses or occupancy square feet to match current classifications exceeds 5 000 square feet Village of Sugar Grove code amnmenadamen 903 3 1 1 Adding at the end of the paragraph in accordance with NFPA 13 NFPA13 Publishing error code book except as provided in Section 903 1 1 1 Sprinkler sentence is incomplete Systems 903 2 Adding sentence An automatic sprinkler syste
26. oms to have ready locking devices which are not an integral part of the doorknob access to egress with use of assembly keys etc Added sentence When scheduling a rough plumbing inspection a Inspections amp Clarifying that the Village of water test must be provided on the drain waste amp vent system per Test Methods Sugar Grove always requires a section 890 1930b of the Illinois State plumbing Code in winter water test that the code says conditions contact the Village of Sugar Grove first may be required Replaced with Building sewers that connect to private sewage Sewer Depth Village doesn t have jurisdiction disposal systems shall be under the jurisdiction of Kane County over septic systems Health Department All other building sewers shall be as specified in Village of Sugar Grove ordinance 2006 Code Amendments Page 5 2006 CODE AMENDMENTS BOOK SECTION RECOMMENDED CODE CHANGE CONTEXT OF REASON FOR CODE CHANGE OD Added sentence All plumbing piping shall be supported or Structural Clarifies where the code fastened direclty to the structural supports of the building Plumbing Attachment required hangers and anchors piping shall not be hung from the roof or floor deck above or other ductwork or piping Subsection added Section 406 4 Drain Pans When washing machines and or water heaters are located on the first or second floor or higher a drain pan shall be required The pan shall have a minimum one in
27. or minimum values of insulation alternative thermal envelope they must still meet our current minimum insulation requirements Replaced compliance for that section s shall be demonstrated in Commercial Details the type of submittal accordance with the applicable provisions of ASHRAE IESNA 90 1 Energy required to show ASHRAE with compliance for all sections shall be demonstrated by including Efficiency compliance per Illinois Capital the compliance forms published in the ASHRAE 90 1 User Manual Development Board Energy the compliance certificates generated by the U S Department of Conservation Law Energy s COMCheck computer simulation or another comparable energy efficiency model that meets or exceeds the standards of ASHRAE 90 1 or DOE COMCheck building meets all code z ON Inserted A certified test and balance report shall be submitted and Testing Requires all mechanical approved prior to final occupancy The Code Official shall have the systems to be properly authority to waive the requirement at his discretion balanced and a report Inserted All piping shall be supported or fastened directly to the Structural Poaiilies code required pipe structural supports of the building Mechanical piping shall not be Attachment anchors hangers and supports hung from the roof or floor deck above or other ductwork or piping to be attached to building Added Subsection Section 501 5 Independent system required Exhaust
28. ormative and not part of the D pipe sizing code vent system sizing exit terminals and 301 1 Added subsection Section 301 1 1 Sugar Grove Climate Zone Climate Zones Clarify which zone Residential and commercial energy efficiency in the Village of Sugar requirements apply since Sugar Grove shall meet or exceed the requirements for climate zone 5 Grove sits close to the border of 2 zones on the map provide documentation that meets the requirements of section 404 times assembly alternative to achieve thermal envelope requirements A Alternative 402 2 1 deleted entire section ceilings with Deletes section that would attic spaces allow a reduction of required insulation R value in a certain 402 2 2 deleted entire section ceilings without Deletes section that would attic spaces allow a reduction of required insulation R value in a certain 2006 Code Amendments Page 2 402 1 4 Added subsection Section 402 1 4 1 Required Documentation Total UA sum Requires designers to submit Thermal envelopes designed using the total UA alternative shall of U factor calculations if they choose this 2006 CODE AMENDMENTS BOOK SECTION RECOMMENDED CODE CHANGE CONTEXT OF REASON FOR CODE CHANGE OD Added subsection Section 404 2 1 Minimum Insulation Values All Simulated Requires that even if a residences designed using the simulated alternative shall meet the performance designer computer models his following requirements f
29. r is taken directly from the outdoors in accordance with Section M1703 Access to such enclosures shall be through a solid door weather stripped in accordance with the exterior door leakage requirements in the International Energy Conservation Code and equipped with a self closing device M1602 1 Added Return air vents connected to the heating and cooling Return Air Requires return air in each system shall be located in every habitable room of a dwelling except room to allow HVAC systems to as prohibited by section M1602 2 work well with interior room eal Deleted in its entirety including all subsections Special piping Village of Siigar Grove does and storage not allow fuel oil storage tanks systems for one and two family G2401 1 Replaced with The installation of fuel gas piping systems fuel gas Clarifies all requirements to be utilization equipment and related accessories venting systems and Compliance met for residential fuel gas combustion air configurations in one and two family dwellings shall installations comply with the applicable provisions of Chapter 24 and 25 inclusive the International Fuel Gas Code and all Village of Sugar 2006 Code Amendments Page 21 2006 CODE AMENDMENTS BOOK SECTION RECOMMENDED CODE CHANGE CONTEXT OF REASON FOR CODE CHANGE OD P2601 1 Replaced with The installation of all plumbing appliances equipment and systems in one and two family dwellings shall comply with the appli
30. s that portions of Electrical service attachments shall be installed in accordance with electrical service installations the requirements of the electrical utility company subject to the fall outside the scope of approval of the Code Official Building Codes and are regulated by laws codes and regulations that the utilities A ICCEC 801 Subsection added Section 801 5 Service Conductors in Yards Connection of Requires the utility companies Electrical services for single family homes shall be located on the service utilities to make their service runs in side of the house closest to the electrical source The service may the easements provided rather only be located on the rear of the house if the garage is located on than the shortest route across the side closest to the electrical source All conductors running from the lot which can cause issues the electrical source shall run parallel to the property line to a point and great expense for owners 90 degrees from the electrical service Conductors shall not run wishing to do future through any portion of the rear yard that would prevent the construction in their yards homeowner from constructing an addition or pool without having to relocate the electrical service conductors ICCEC 1201 1 Replaced NFPA amp with NFPA 70 National Elelctrcial Code 2005 Edition ICCEC 1202 2 methods shall be permitted to be used in one and two family dwellings only ICCEC 1202 5 Repla
31. t access to a main service disconnecting mans and for access to disconnecting all panel boards etc that contain breakers or fuses that protect any means Each tenant should be electrical devices in that tenant unit Direct access means a able to drop power to his unit to common area that has no locks or the tenant can get to the panel or allow for repairs and in case of switchboard without going through another tenant space emergency ICCEC 1202 Added subsection Section 1202 24 Exterior Disconnect for Exterior Safety for firemen that normally Services Over 400A All buildings with a main service at 400 amps disconnect for have to break out the meter or more shall provide a means of disconnect at the building services over face to drop the main power exterior 400A from the building exterior ICCEC 1202 Added subsection Section 1202 25 Location of Overcurrent Location of Clarifies the ambiguous term Protection The service overcurrent device shall be connected by no overcurrent immediately adjacent used by protection the NEC to mean no more than ICCEC 1202 Independent Clarifies the NEC requirements Methods All lighting fixtures panel boards switchgear and or supporting for support of lighting fixtures supporting devices for conduit systems installed in buildings or means and parts of the structure not to structures shall be installed and supported by the building structural be used for support components completely indepe
32. t in operation operating pe laren Adopted and Inserted Appendix Diagrams of combustion air openings and chimney connector pass throughs aa 108 3 Replaced with The designation of a structure as unfit for occupancy Uninhabitable Differenciates between or use and the posting of a placard of such unfit structures shall be Structures uninhabitable and condemned carried out in compliance with the following requirements Any and sets up procedure for 801 14 Added subsection Section 801 14 1 Automatic Shutoff Power Connections to Requires systems with power exhausters shall be electrically connected to each appliance to Exhauster exhausters to not function if the structure which is found by the Code Official to have any dealing with uninhabitable structures IPMC 302 3 Added sentence All parking lot striping including accessible i Adding Illinois Accessibility parking spaces and signage shall be maintained and updated in Property Areas Code requirement accordance with the requirements as specified in the Illinois A fe 302 4 Inserted 8 eight inches o ae ee maximum weed height Property Areas anil 304 14 Inserted April 1 and November 1 Insect screens Clarifies dates that insect screens are required on door and window openings 2006 Code Amendments Page 4 2006 CODE AMENDMENTS BOOK SECTION RECOMMENDED CODE CHANGE CONTEXT OF REASON FOR CODE CHANGE A OD IPMC 307 Added Subsection Section 307 4 Placement