Home
Communication Module
Contents
1. 0 C to 55 C free convection 40 C to 70 C 95 at 25 C LonWorks Communication Module User s Manual Safety Protection standard Radio interference suppression Certification Overvoltage protection Fuse Order Data IDEC SmartRelay Expansion Module LonWorkKs Communication Module IP 20 EN 55011 Limit Value Class B CE UL 508 VDE 0631 IEC 61131 2 80 mA slow action fuse FL1B CL1C012 LonWorks Communication Module User s Manual 6 Index Mechanical coding pin 1 3 Power supply c0006 1 3 RUN STOP LED 1 3 Service button 0 1 3 SERVICE LED 1 3 SHEP sii assekelehbessesebatoes 1 3 SNVT_lev_percent 4 3 4 4 Z T _obj_ request 4 4 RNANNNNMN ZZZZZZ 4 LonWorks Communication Module User s Manual
2. Occupancy 0 occupied gt 0 1 not occupied gt 1 2 bypass gt 0 3 standby gt 1 SNVT_tod_event Scheduler program Just current state O occupied 3 standby SNVT_temp_p Room temperature SNVT_lux Brightness lighting level SNVT_lev_percent Position LonWoRrks Communication Module User s Manual Assignment of the SNVT to the inputs and outputs SNVT Name Assignment Digital SNVT_switch nvoSwitchDO051 Q5 outputs nvoSwitchDO061 Q6 nvoSwitchDO071 Q7 nvoSwitchDO081 Q8 nvoSwitchDO091 Q9 nvoSwitchDO101 Q10 nvoSwitchDO111 Q11 nvoSwitchDO121 Q12 SNVT_occupancy nvoOccDO131 Q13 nvoOccDO141 Q14 SNVT_tod_event nvoTodDO151 Q15 nvoTodDO161 Q16 Digital inputs SNVT_switch nviSwitchD1091 19 nviSwitchDI101 110 nviSwitchDI1 114 111 nviSwitchDI121 112 nviSwitchDI131 113 nviSwitchDI141 114 nviSwitchDI151 115 nviSwitchDI161 116 nviSwitchDI171 117 nviSwitchDI181 118 nviSwitchDI191 119 nviSwitchDI201 120 nviSwitchDI211 121 nviSwitchDI221 122 SNVT_occupancy nviOccDI231 123 nviOccDI241 124 Analog inputs SNVT_temp_p nviTempAl081 Al8 SNVT_lux nviLuxAl071 Al7 SNVT_switch nviSwitchAlO11 Al1 nviSwitchAl021 Al2 nviSwitchAl031 Al3 nviSwitchAl041 Al4 nviSwitchAlO51 Ald nviSwitchAl061 Al6 SNVT_lev_percent nviLev_perAl011 Alt nviLev_perAl021 Al2
3. LON E A B LN Protect the LoNWoRks Communication Module with a 80 mA slow action fuse if desired recommended LonWorks Communication Module User s Manual 2 4 2 2 2 Connecting the LON This connection is made using the two screw terminals A B eo RUN STOP fo SERVICE FL1B CL1C12 ae OQOO0O Service QVOOOO A B LON You can start the programming by pressing the Service 4 button NOTE Don t apply force when pressing the Service 4 button When contact has been made the LED will light up in orange LonWoRrks Communication Module User s Manual 2 5 3 Putting the LonWorxs Communication Module into operation A LONMARK certified application was loaded into the LON module at the factory 3 1 Step by step 1 ON Interrupt the voltage to the IDEC SmartRelay The IDEC SmartRelay and its modules do not have power switches Mount the LONWoRKS Communication Module Connect the power supply to the LONWORKS Communication Module Connect the LON bus lines to the LONWoRKS Communication Module Remove the label with the Neuron ID from the LONWoRKS Communication Module and stick it on the network plan at the LONWORKS Communication Module s installed location The Neuron ID is also given as a bar code on the label Apply power to the IDEC SmartRelay and LONWorRks Communication Module If multiple LONWORKS Communication Modules have been ins
4. nviLev_perAl031 Al3 nviLev_perAl041 Al4 nviLev_perAl051 Al5 nviLev_perAl061 Al6 Immediately after powered up LONWORKS communication modules send digital output network variable 0 to destinations LonWorks Communication Module User s Manual 4 4 Relationships between analog input values and SmartRelay internal values are listed in the table below SNVT SNVT_lev_percent Analog input value Internal value of FL1B CL1C12 from network 0 0 10 100 50 500 SNVT SNVT_switch Analog input value Internal value of FL1B CL1C12 from network Value state 0 0 0 0 Value state 0 0 1 256 Value state 100 0 0 200 Value state 100 0 1 456 SNVT SNVT_temp_p Analog input value Internal value of FL1B CL1C12 from network 273 1 C 2731 oC 0 100 0 C 1000 327 6 C 3276 SNVT SNVT_lux Analog input value Internal value of FL1B CL1C12 from network Olux 0 10000lux 200 50000lux 1000 65500lux 1310 LonWorks Communication Module User s Manual 4 5 4 3 LON configuration parameters All of the digital outputs are configured with a Send Heartbeat The LON application is configured using the Config Network Variables The following SCPT are available SCPT Description Name Assignment Default SCPTmaxSendTime Sen
5. possibility of deviations and therefore we cannot guarantee that there are no errors in this document The information in this document is checked regularly and any necessary corrections are then made in the next release issued We are of course thankful for any suggestions for improvements LonWorks Communication Module User s Manual ii Table of Contents 1 Getting to know LONWORKS Communication Module 1 1 1 1 What is LONWORKS Communication Module 05 1 1 1 2 The construction of the LONWORKS Communication Module 1 2 2 Mounting and wiring the LONWORKS Communication Module 2 1 2 1 General QuidelineS 2 4 cc eetseyiseieenasdhenin cater ae 2 1 2 2 Wiring the LONWORKS Communication Module 2 3 2 2 1 Connecting the power supply Sas 2 2 2 Connecting the LONE y isdn nae as elects aa 3 Putting the LONWORKS Communication Module into operation3 1 3 1 Step by Step i vec sesecdyeteseeiis tas tree erties ieee aed 3 1 3 2 The LONWORKS Communication Module operational status3 2 3 3 Behavior in case Of a fault ee eee cece eee eeeeeteeetseeeeteeeees 3 3 4 Supported functions ccccceecceeeeseeeeeeeeeeeeeeeeeeeeeeenseeeeeeseeeeeeseeeenes 4 1 4 1 Virtual inputs OUTPUTS ssania a e aain 4 1 4 2 Available network variables eseseeseeseeeeereerreerrerrerrrerrerreeree 4 3 4 3 LON configuration parameters cccceeeeceeeeeeeeeeeteeeteneeeeeaee 4 6 4 4 Inputs Outp
6. with free virtual BUS inputs To map the IDEC SmartRelay inputs 11 18 as outputs on the BUS these must be joined with free virtual BUS outputs in the IDEC SmartRelay application Feedback value Feedback variables are required for status displays for a variety of applications primarily lighting applications These are not directly supported by the LONWoRKS Communication Module However an internal operation using IDEC SmartRelay inputs outputs is enough to display the status information on the IDEC SmartRelay Alias table entries The LONWoRKS Communication Module supports 8 alias table entries LonWoRrks Communication Module User s Manual 4 7 5 LonWorks Communication Module Specifications Electrical Data Supply voltage Permissible range Current consumption Data transmission rate LON Physical Construction Dimensions W x H x D Weight Mounting options Connections IDEC SmartRelay connection LON connection TP FT 10 Max torque Power supply Max torque Standard bus lines to use Environmental Conditions Permissible operating temperature Storage and transport temperatures Humidity 24 V AC 24 V DC 15 10 15 20 max 33 mA 78 kBaud 36 x 90 x 55 mm approx 85g 35 mm rail wall mounting Standard expansion interface For IDEC SmartRelay 12 24 V and 100 240 V 2 screw terminals 0 5 2 5 mm 0 5 Nm 2 screw terminals 0 5 2 5 mm 0 5 Nm 2 x 2 x 0 8 mm
7. Fi DEC F L 1 D series ipec SmartRelay LONWORKS Communication Module User s Manual iy a a j i J uJ Q z IDEC CORPORATION Safety Notices A DANGER A WARNING A CAUTION CAUTION WARNING Indicates that death severe bodily injury or substantial material damage will occur if the corresponding safety measures are not taken Indicates that death or severe bodily injury may occur if the corresponding safety measures are not taken With the warning triangle this indicates that minor bodily injury may occur if the corresponding safety measures are not taken Without the warning triangle this indicates that material damage may occur if the corresponding safety measures are not taken This indicates that an undesirable result or condition may occur if the corresponding instructions are not observed LonWorks Communication Module User s Manual Copyright IDEC CORPORATION All rights reserved You may not transfer or duplicate this document or utilize or reveal its contents unless expressly authorized in writing In the case of a violation you will be obliged to pay damages All rights reserved in particular in the event that a patent is granted or that a utility model is registered Disclaimer of liability We have checked that the contents of this document correctly describe the associated hardware and software Nonetheless it is impossible to exclude the
8. RKS Communication Module To wire the LONWORKS Communication Module use a screwdriver with 3 mm wide blade You do not need to use wire end ferrules when clamping the wires NOTE After the installation the terminals must be covered To protect personnel against unintentional contact with the portions of the LONWoRKS Communication Module that are conducting electricity the appropriate national and local standards must be observed The LONWoRKS Communication Module is a double insulated switching device A protective grounding conductor is not necessary LonWorks Communication Module User s Manual 2 3 2 2 1 Connecting the power supply The LONWoRKS Communication Module has been designed to serve as a Slave module for the IDEC SmartRelay controller It must be connected to a 24 V AC DC supply voltage Please observe the relevant instructions that are found in the product information that was included with your equipment as well as the technical data regarding the permissible voltage tolerances main frequency and current consumption Connecting How to connect the LONWoRKS Communication Module to the power DC supply AC supply i AC24V tT L M L M QVKOOOO QVOOCOCO 24VAC DC E 2c o IDEC iDec e RUN STOP eo RUN STOP SERVICE SERVICE FLIB CLICI2 ae FLIB CLICI2 at goH OOO0O0OQO Service Service GQGKOOOCO QHKOOCO A B
9. controller functionality for the LON with the capability of setting or changing parameters or operations quickly simply and without a programming device LonWorks Communication Module User s Manual 1 1 1 2 Communication Module 36 5 08 53 The construction of the LONWORKS 000 Si mm z ay m IDEC 3 RUN STOP 2 SERVICE FL1B CL1C12 z 7 84 5 08 7 84 be S000 Service 90 OOO LON ap 5 3 5 08 5 3 k 58 LonWorks Communication Module User s Manual 1 L M S 60000 E 24vAC DC dh I E Dec T RUN stop 4 m SERVICE FLIB CL1C12 kd 5 QOOCO0O Service SSHOOSOO A B LON op T1 1 Power supply 2 Bus lock slider interface to the IDEC SmartRelay The RUN STOP LED for IDEC SmartRelay communication The SERVICE LED Input LON connection Expansion interface to the IDEC SmartRelay Mechanical coding pin Service button Version number example x represents Version 1 oO OONDOOSA LonWorks Communication Module User s Manual 1 3 2 1 Mounting and wiring the LonWorks Communication Module General g
10. d Heartbeat cpMaxSendTDOO5 Q5 0 min SCPTmaxSendTime Send Heartbeat cpMaxSendTDOO6 Q6 0 min SCPTmaxSendTime Send Heartbeat cpMaxSendTDOO7 Q7 0 min SCPTmaxSendTime Send Heartbeat cpMaxSendTDOO8 Q8 0 min SCPTmaxSendTime Send Heartbeat cpMaxSendTDOOY Q9 O min SCPTmaxSendTime Send Heartbeat cpMaxSendTDO10 Q10 O min SCPTmaxSendTime Send Heartbeat cpMaxSendTDO11 Q11 O min SCPTmaxSendTime Send Heartbeat cpMaxSendTDO12 Q12 O min SCPTmaxSendTime Send Heartbeat cpMaxSendTDO13 Q13 O min SCPTmaxSendTime Send Heartbeat cpMaxSendTDO14 Q14 O min SCPTmaxSendTime Send Heartbeat cpMaxSendTDO15 Q15 O min SCPTmaxSendTime Send Heartbeat cpMaxSendTDO16 Q16 O min After changing configuration parameters shut down and power up again When power is restored the new configuration parameters take effect LonWorks Communication Module User s Manual 4 4 4 5 Inputs Outputs special considerations Allocating the IDEC SmartRelay inputs outputs All of the inputs outputs which are physically allocated on the IDEC SmartRelay or an expansion module are not available for allocation as virtual inputs outputs Only the outputs on additional I O modules can be issued in parallel to the LON Using the IDEC SmartRelay inputs outputs on the LONWORKS Communication Module To access the IDEC SmartRelay outputs Q1 to Q4 directly via the bus communications these must be joined in the IDEC SmartRelay application
11. e of a fault IDEC SmartRelay Power failure If the power to the IDEC SmartRelay fails or the communications with the IDEC SmartRelay Master or the communications partner to the left is interrupted the outputs will be set to 0 The RUN STOP LED will light in RED after one second IDEC SmartRelay Power returns The IDEC SmartRelay will startup and the LONWoRKsS Communication Module will send the parameterized status LONWoRKS Communication Module Power failure All of the inputs of the LONWOoRKS Communication Module will be set by the IDEC SmartRelay Master to 0 LONWoRKS Communication Module Power returns All of the IDEC SmartRelay Master outputs will be updated LonWorks Communication Module User s Manual 3 3 4 1 Supported functions The LONWOoRKS Communication Module handles the communications between The IDEC SmartRelay and LON Supports virtual inputs and outputs for the communication via the LON Virtual inputs outputs The standard LONWoRKS Communication Module application fills the complete IDEC SmartRelay process image A1 A2 11 12 13 14 I5 16 1718 oooo0oo0oo0oo0 g FL1B H12RCE FL1B CL1C12 OO OO OO OO A3 A8 Qi Q2 Q3 Q4 19 124 Q5 Q16 LON 11 12 13 14 I5 16 1718 19 110111 112 OOO00000 FL1B H12RCE FL1B M08B2R2 FL1B M08B2R2 FL1B CL1C12 OO OO OO OO Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 A1 A2 Q9 Q16 EON LonWorks Communicat
12. ion Module User s Manual 4 1 FL1B M08B2R2 FL1B CL1C12 11 12 13 14 15 16 I7 18 19110111112 113 124 Q9 Q16 1 To map the IDEC SmartRelay inputs 11 to 18 112 as outputs on the BUS these must be joined with free virtual BUS outputs Q5 Q9 to Q12 in the IDEC SmartRelay application 2 Operations basic functions BF special functions SF useable within the IDEC SmartRelay application feedback value 3 To access the IDEC SmartRelay application Q1 to Q4 Q8 directly via the bus communications these must be joined with free virtual BUS inputs 113 to 124 in the IDEC SmartRelay application LonWorks Communication Module User s Manual 4 2 4 2 Available network variables The LONWoRKS Communication Module s standard LON application contains the network variables described below Relationships between version number and XIF file Verion number XIF file 3 F0233100 5 F0233102 See page 1 3 for more details LonMark Node Object Quantity Name Type Description 1 nviRequestO SNVT_obj_request Request object mode 1 nvoStatusO SNVT_obj_status Output object status LonMark Controller Object SNVT Description SNVT_switch Switch light alarm window contact free inputs outputs value 0 state 0 inactive value gt 0 state 1_ active SNVT_occupancy
13. talled repeat Steps 1 to 6 for each LONWoRKS Communication Module To log a LONWOoRKS Communication Module in on a LON network you can either press the Service button or enter the Neuron ID directly in the LON using the Installation Tool or by reading the label with a bar code scanner The LONWoRKS Communication Module is then registered in the LON database and ready for operation For further details regarding the LON installation please read the corresponding documentation LoNWoRKS Communication Module User s Manual 3 1 3 2 operational status The LONWoRKS Communication Module is a IDEC SmartRelay expansion module This module has two LED displays RUN STOP LED SERVICE LED SmartRelay Service LED The LONWORKS Communication Module Communication with the IDEC LED RUN STOP Lights In Green RUN Red STOP Orange The LONWORKS Communication Module is communicating with the device on the left The LONWORKS Communication Module is not communicating with the device on the left The LONWORKS Communication Module s initialization phase LED SERVICE Lights In Module s initialization phase Communication Green Red Orange Green Orange Flashing Configure Service The Unconfigure button pressed LONWORKS LonWorks Communication Module User s Manual 3 2 3 3 Behavior in cas
14. uidelines The following guidelines should be observed when mounting wiring your LONWORKS Communication Module When wiring the LONWoRKS Communication Module make certain that you follow all of the applicable and legally binding standards Observe all of the relevant national and regional regulations when installing and operating the device Check with the local authorities regarding the standards and regulations that must be observed in your special case Make certain that the device is de energized Use only approved bus cables Make certain that the specified cable lengths are used and that the correct terminating resistors are installed properly The LONWoRKS Communication Module must always be installed as the last module on the right of the IDEC SmartRelay since you may not install other expansion modules onto the LONWoRKS Communication Module LonWoRrks Communication Module User s Manual 2 1 Please notice The LONWoRKS Communication Module must have its own power supply 24 V AC DC NOTE This module may only be mounted and wired by qualified personnel who know and observe the generally applicable guidelines and applicable regulations and standards Observe the assembly and disassembly instructions in the IDEC SmartRelay manual A WARNING The expansion module may only inserted or removed when the power is off LonWorks Communication Module User s Manual 2 2 2 2 Wiring the LONWO
15. uts special considerations ccceeeeeeeeeee 4 7 4 5 Alias table entries cece eee cee eens eeneeceeeeseeseneseeessaeeeaeeeeaes 4 7 5 LONWORKS Communication Module Specifications 5 1 LoNnWorRKs Communication Module User s Manual 1 1 Getting to know LONWoRKS Communication Module What is LONWORKS Communication Module The Local Operating Network LONWOoRKS Communication Module communications module is an interface for connecting IDEC SmartRelay onto a LON network The IDEC SmartRelay communications module has been implemented as a Slave module for the IDEC SmartRelay control module The module supports communication between the IDEC SmartRelay Master and external LON devices via a LON The LONWoRKS Communication Module is a bus station on the LON and allows the IDEC SmartRelay to communicate with other LON devices What are the capabilities of the LONWORKS Communication Module The LONWoRKS Communication Module presents the current states of the LON stations to the IDEC SmartRelay which is thus able to use its logical functions and timers to join them together In the process the LON signals can also be combined with the signals of the local IDEC SmartRelay inputs and outputs The LONWoRKS Communication Module then transmits every change of the output signal via the LON The combination of IDEC SmartRelay and LONWoRKS Communication Module gives the user a decentralized