Home

Model 6380 User guide - Fitch Security Integration

image

Contents

1. 22 24 OPTIONS EER EG EG De 20 21 REMOVING USER IDS 19 SET DATE TIME eis sn RD ge 13 SET TIME COMMANDS 15 SETTING USER IDS Codes 16 18 SETTING USER NAMES 22 24 SETTING USER NAMES TEMPLATE 30 SETTING USER OPTIONS 20 21 SLOW ENTRY ALARM 3 4 SYSTEM LOG ade ene 27 TIME asa nde na ean Ge 13 USER SET OWN ID 26 WARNING MESSAGES 29 Page 32
2. 1 ENTER NEW MONTH VALUE JAN 1 FEB 2 AND PRESS THE RETURN BUTTON DISPLAY SHOWS SET DAY 1 ENTER NEW DAY VALUE 01 TO 31 AND PRESS THE RETURN BUTTON DISPLAY SHOWS SET HOUR 16 ENTER NEW HOUR VALUE 01 TO 23 AND PRESS THE RETURN BUTTON DISPLAY SHOWS SET MINUTE 15 ENTER NEW MINUTE VALUE 01 TO 59 AND PRESS THE RETURN BUTTON DISPLAY SHOWS SET SECOND 21 SET DATE TIME cont Page 13 ENTER NEW SECOND VALUE 01 TO 59 AND PRESS THE RETURN BUTTON Effective April 2002 automatic Daylight Saving Change was introduced into all panel firmware If DISPLAY SHOWS AUTO HOUR CHANGE YES and you wish the time change to occur automatically then PRESS THE RETURN BUTTON to accept this feature and the panel will return to normal operation If however you live in a region of the country that does not use Daylight Saving Time Change then PRESS THE NO BUTTON DISPLAY SHOWS AUTO HOUR CHANGE NO PRESS THE RETURN BUTTON to accept this feature and the panel will return to normal operation If you have a panel with firmware produced before April 2000 the panel requires a semi automatic change which is described in the next section Page 14 DAYLIGHT SAVING TIME CHANGE Hour Change This function is used to prepare the panel to automatically adjust forward or backward for the daylight saving time change If you have a panel with firmware produced befo
3. BUTTON DISPLAY SHOWS USER SET OWN ID THEN ENTER CODE 1 The system requires you to enter two codes one of which it will choose for you to keep ENTER A CODE AND DISPLAY SHOWS ENTER CODE 2 DISPLAY BRIEFLY SHOWS SELECTED CODE X where X is choice 1 or choice 2 The system then returns to the DISARM mode The new user code supercedes the old temporary code and the latter will no longer be valid Page 27 SYSTEM LOG This function allows authorized users the ability to either print or view the historical log for the Security zones or for the Door Access zones ENTER USER CODE AND THEN PRESS THE YES BUTTON DISPLAY SHOWS ALARM ACCESS DISARM HELP PRESS THE DISARM BUTTON TO SELECT ALARM THE DISPLAY SHOWS SYSTEM LOG AND THEN PRINT LOG A yes or no answer is required PRESS YES BUTTON if a serial input printer has been connected to the panel the log contains the previous 1000 historical events or PRESS NO BUTTON if no printer connected and the log will be sequentially displayed in reverse order most recent event first Note that date and time are always displayed on the first line and are now separated with an asterisk indicating that the panel is displaying the log You may fast forward through the log by repeatedly pressing the DISARM button or rewind the log by pressing the PART ARM VEVENING ARM button Note also that one to three dashes appear in the first
4. each keypad can be programmed to control selected areas ARMING AN AREA PARTITION Close all zones that are monitored within the desired partition Press the button on your keypad to view the Area status followed by the Zone status If all zones assigned to the area partition are closed not displaying then you may begin arming that partition ENTER USER CODE THEN PRESS THE ARM AREA PART ARM 2 BUTTON THE KEYPAD WILL DIS PLAY THE FIRST AVAILABLE AREA TO BE ARMED DISPLAY SHOWS ARM AREA X Area Number X IF THIS IS THE AREA YOU DESIRE PRESS THE YES BUTTON OTHERWISE PRESS THE NO BUTTON UNTIL THE DESIRED AREA APPEARS PRESS THE YES BUTTON TO SELECT THE AREA Alternatively you may enter the area number and press the RETURN button IF THERE ARE MORE AREAS AVAILABLE FOR ARMING DISPLAY WILL SHOW ARM AREA Y Area Number Y IF THERE ARE NO MORE AREAS TO ARM PRESS THE BUTTON TO EXIT If the area you have Page 1 ARM DISARM AREAS 1 TO 32 cont selected is the last area in the list the keypad will auto exit Leave the area immediately through the entry exit door ZONES OPEN AT ARMING If some AREA X zones are still open thereby preventing the arming the keypad will beep and DISPLAY SHOWS NOT ACCEPTED followed by the next area available for arming Press the button to return to date and time or if the area chosen is the last area available the keypad will auto exi
5. the Master user to record the names of the 248 general users This is useful when examining the log ENTER MASTER USER CODE THEN PRESS THE SHIFT BUTTON AND THEN PRESS THE DISARM BUTTON DISPLAY SHOWS USER SETUP AND IN A MOMENT IDS OPTIONS NAMES DISARM PART2 HELP PRESS HELP BUTTON DISPLAY SHOWS ENTER USER NO 2 ENTER USER NUMBER AND PRESS RETURN BUTTON DISPLAY SHOWS The cursor will be flashing at the far left of the display The letters of the alphabet are associated with the 19 buttons and the cursor is used to select the required characters Refer to the template chart at the back of this booklet for the letter assignments When the cursor is pointing UP the number buttons for example are as marked Press the SHIFT button once and the cursor will point to the LEFT The number buttons now have a new set of alphabetic designations Press the SHIFT button again and the cursor will point to the RIGHT The number buttons now have an Page 23 SETTING USER NAMES cont other set of alphabetic and symbol designations Press the SHIFT button again and it will return to the UP position The direction of the cursor always indicates the character to be chosen The remaining buttons also have letters assoc iated with them For example to enter a space character position the cursor pointing to the left and press the RETURN button To save a name entry position the cursor UP
6. three column positions on the upper line of the display Each Page 28 SYSTEM LOG cont new complete log display increments the dash To terminate either the printing or displaying of the log PRESS THE NO BUTTON DISPLAY SHOWS ABORTED AND THEN ALARM ACCESS DISARM HELP PRESS THE NO BUTTON TO EXIT The system then returns to the DISARM mode Page 29 WARNING MESSAGES If any of the following messages appear silence the beeping tone by following the ACKNOWLEDGE function see page 8 The message below indicates that the AC power has been removed from the system DISPLAY SHOWS AC POWER FAIL The message below indicates that the standby battery is faulty or disconnected DISPLAY SHOWS BATTERY PROBLEM The message below indicates that a TAMPER condition exists on one of the zones DISPLAY SHOWS ZONE TAMPER ALARM The message below indicates that a panel fuse has blown DISPLAY SHOWS F2 F3 FUSE BLOWN Should any of the above messages be displayed CALL FOR SERVICE IMMEDIATELY Page 30 SETTING USER NAMES TEMPLATE CHART The drawing below shows the various letters of the alphabet and characters that are available for describing zones and user names When the cursor is shifted left lt by pressing the SHIFT DELETE button the left character is selected D E F etc When the cursor 15 shifted right gt by again pressing the SHIFT DELETE button the right character is selec
7. ING WITH INTRUDER ALARM AND ZONE DESCRIPTION Page 3 DISARM Disarm mode is used to simultaneously turn off all areas of the system after entering the premises ENTER USER CODE THEN PRESS DISARM BUTTON DISPLAY SHOWS WAIT THEN AREA DISARMED AND THEN DAY DATE TIME ALARM ON ENTRY If too much time is taken to disarm the system then a full alarm will occur When the panel is finally disarmed DISPLAY SHOWS DAY DATE TIME AND FLASHES SLOW ENTRY ALARM ALTERNATING WITH INTRUDER ALARM AND ZONE DESCRIPTION Page 4 FULL ARM AWAY ARM FULL ARM AWAY mode is used to simultaneously turn on all areas of the system when you are leaving the premises Close all zones Press the button to display Armed status followed by Zone status If no zones are displayed this means that the panel may be fully armed Note EXIT zones and FOLLOWER zones that are open on the exit route are allowed and will not prevent the FULL ARM mode from occurring ENTER USER CODE THEN PRESS FULL ARM AWAY BUTTON DISPLAY SHOWS WAIT THEN AREA ARMED AND IN A MOMENT THE DISPLAY MAY GO BLANK If any zones other than EXIT or FOLLOWER zones are open when FULL ARM mode is chosen the keypad beeps and DISPLAY SHOWS NOT ACCEPTED THEN DAY DATE TIME When the system is successfully armed the exit buzzer will start to pulse for the duration of the exit time Exit the premises promptly The system is fully armed when the buzzer no longer s
8. MODEL 6200 3GS USER MANUAL For 32 Partition Residential and Commercial Control Panels VERSION 5 INTRAMERICA SECURITY TECHNOLOGIES C 2002 Issued Jan 2002 Order Code 6380A CONTENTS ARMIDISARM AREA 1 32 1 GROUP ARM DISARM GROUP ARM DISARM INTERIOR OFF DISARM 4 EAN 5 EN AM 7 AUDIBLE SILENCE 7 ACKNOWLEDGE ALARMS 8 DOOR CHIME 8 BERDE R 9 SHUNT N sedate 10 CLEAR sees 11 SET DATE TIME usta 13 DAYLIGHT SAVING TIME CHANGE 14 SET TIME COMMANDS 0000 15 SETTING USER IDS 16 REMOVING USER IDS Codes 19 SETTING USER OPTIONS 20 SETTING USER NAMES 22 EDITING USERNAMES 25 USER SET OWN ID 26 SYSTEM LOG SR N EE 27 WARNING MESSAGES 29 SETTING USER NAMES TEMPLATE 30 INDEE ode OE be 31 ARM DISARM AREAS 1 32 In a partitioning system the protection is divided into a maximum of 32 areas or partitions Each user is given the authority to arm disarm one or more areas Additionally
9. ONS NAMES DISARM PART2 HELP PRESS THE DISARM BUTTON DISPLAY SHOWS SET ID REMOVE ID DISARM HELP PRESS DISARM TO SELECT SET ID DISPLAY SHOWS ENTER USER NO 2 MASTER or User No 2 ENTER USER NUMBER OR PRESS DISARM PART ARM 1 BUTTON TO SCROLL THROUGH LIST PRESS RETURN BUTTON TO SELECT A USER Page 17 SETTING USER IDS Codes cont DISPLAY SHOWS USER CODE ____ 2 sq DISPLAY SHOWS ENTER USER NO X NAME or User No X where X is one higher than the previous user number ENTER USER NUMBER OR PRESS DISARM PART ARM 1 BUTTON TO SCROLL THROUGH LIST PRESS RETURN BUTTON TO SELECT A USER DISPLAY SHOWS USER CODE ____ ENTER 6 6 DISPLAY SHOWS ENTER USER NO Y NAME or User No Y At this point you may continue to enter the codes for the rest of the users or you may PRESS NO BUTTON to exit from this option DISPLAY SHOWS SET ID REMOVE ID DISARM HELP PRESS NO AGAIN AND Page 18 SETTING USER IDS Codes cont DISPLAY SHOWS IDS OPTIONS NAMES DISARM PART2 HELP PRESS THE NO BUTTON TWICE to return to date and time NOTES i If you enter a duplicate code the keypad will re display USER CODE _ _ _ _ Re enter a different value or press the RETURN key to leave the old value unchanged ii A higher user number cannot assign codes to a lower user number e g user 45 cannot assign codes to
10. Y DATE TIME IF YOU SELECT THIS FUNCTION AND SOME ZONES HAVE BEEN PREVIOUSLY SHUNTED THEN THE DISPLAY WILL SHOW CLEAR SHUNTS TO REMOVE SOME OR ALL OF THE SHUNTS PRESS THE YES BUTTON DISPLAY SHOWS ALL ZONES a TO REMOVE ALL SHUNTS PRESS THE YES BUTTON DISPLAY SHOWS SHUNT FROM 1 TO SHUNT NEW ZONES ENTER ZONE NUMBER AND PROCEED AS ABOVE TO QUIT PRESS THE NO BUTTON AND THEN TO EXIT TO DATE AND TIME PRESS THE NO BUTTON AGAIN Page 11 ZONE SHUNT cont b TO SELECTIVELY REMOVE SOME SHUNTS PRESS THE NO BUTTON DISPLAY SHOWS FROM ZONE 1 1 ZONE DESCRIPTION ENTER THE VALUE OF THE ZONE TO BE CLEARED FOR EXAMPLE 5 DISPLAY SHOWS FROM ZONE 5 5 ZONE DESCRIPTION IF A RANGE OF ZONES IS TO BE CLEARED ENTER THE UPPER LIMIT OR IF ONLY ZONE 5 IS TO BE CLEARED PRESS THE RETURN BUTTON DISPLAY SHOWS TO ZONE 5 5 ZONE DESCRIPTION PRESS THE RETURN BUTTON AND THE DISPLAY SHOWS CLEARED AND IN A MOMENT SHUNT FROM 1 TO SHUNT NEW ZONES ENTER ZONE NUMBER AND PROCEED AS ABOVE TO QUIT PRESS THE NO BUTTON AND THEN TO EXIT TO DATE AND TIME PRESS THE NO BUTTON AGAIN Page 12 SET DATE TIME This function is used to change the date and time ENTER USER CODE THEN PRESS SHIFT BUTTON AND THEN PRESS THE 9 BUTTON DISPLAY SHOWS SET DATE TIME THEN SET YEAR 1998 ENTER NEW YEAR VALUE AND PRESS THE RETURN BUTTON DISPLAY SHOWS SET MONTH
11. and press the RETURN BUTTON As an example we shall enter the name WENDY MILLER PRESS SHIFT SHIFT AND THEN 9 You should now see a W and the cursor should be pointing to the right DISPLAY SHOWS w gt PRESS SHIFT SHIFT AND PART ARM 2 NIGHT DISPLAY SHOWS WE lt PRESS 4 PART ARMI EVENING AND OT DISPLAY SHOWS WENDY lt PRESS RETURN BUTTON AND THEN 3 2 2 PART ARM 2 NIGHT 7 AND THEN PRESS SHIFT SHIFT to return the cursor to the up position If a mistake is made see EDITING USER NAMES on page 25 Page 24 SETTING USER NAMES cont DISPLAY SHOWS WENDY MILLER PRESS RETURN BUTTON DISPLAY SHOWS ENTER USER NO X where X is one higher than the previous user number At this point you may continue to enter the names for the rest of the users or you may PRESS NO BUTTON to exit from this option DISPLAY SHOWS IDS OPTIONS NAMES DISARM PART2 HELP PRESS NO BUTTON to exit to DISARM mode Note When you exit from the options or names you will be prompted to Print Users If a printer is connected to the control panel you may like to make a record of your data Press YES and the display will print a header and then ask if you wish a record of the users If this is required press the YES button and you will be asked for a User ID The only valid entry is the code for the Master user user number 2 Enter this
12. anel will execute an arming of the system If the premises are unattended then the timer will expire and the arming will occur Note that if the panel has been previously armed then no action will occur when this task executes ENTER USER CODE PRESS SHIFT BUTTON AND THEN PRESS THE BACKSPACE BUTTON DISPLAY SHOWS SET TIME COMMANDS THEN MAY SHOW 02 00 DAYLIGHT SAVING PRESS RETURN BUTTON UNTIL DISPLAY SHOWS 24 00 AREA 1 AUTO ARM A value of 24 00 means that the task will not operate Enter a 4 digit time value military time to indicate when you wish to be alerted about the impending arming and press the RETURN to complete the entry Note that this time will apply to every day of the week The next area will be displayed and again enter the appropriate time or leave as 24 00 In a similar manner examine all time commands and the display will return to date and time Page 16 SETTING USER IDS Codes This function allows a Master user to assign unique 4 8 digit ID codes to each of the 248 general users If 4 digit code operation has been chosen the valid codes are 0001 to 9999 If 5 digit code operation has been chosen the valid codes are 00001 to 99999 etc In this section we shall assign to two users the four digit codes 1234 and 5678 ENTER MASTER USER CODE THEN PRESS THE SHIFT BUTTON AND THEN PRESS THE DISARM BUTTON DISPLAY SHOWS USER SETUP AND IN A MOMENT IDS OPTI
13. c On the top line the system is now asking for an answer That is does the user want to select the option displayed PRESS YES BUTTON if yes and the system will execute the option displayed To view the next choice press the RETURN button To go back to a previous selection press the PART ARM 1 EVENING button The lower line shows the procedure to follow for direct access to a function e g to clear the display without using the Help option enter Code plus 0 zero button To exit from this function press the NO button at any time Page 9 ZONE SHUNT BYPASS This function allows the user to place a zone out of service e g loading door window etc Subsequent disarming of the area will remove only the shunts by passes applied to that area Re entry into this function allows removal of some or all of the shunts bypasses ENTER USER CODE THEN PRESS THE NO BUTTON DISPLAY SHOWS SHUNT MODE THEN ZONES DOORS DISARM HELP PRESS THE DISARM BUTTON TO SELECT ZONES DISPLAY SHOWS SHUNT FROM 1 ENTER THE NUMBER OF THE ZONE TO BE SHUNTED FOR EXAMPLE ZONE 5 DISPLAY SHOWS SHUNT FROM 5 PRESS THE RETURN BUTTON DISPLAY SHOWS SHUNT 5 PRESS THE RETURN BUTTON DISPLAY SHOWS 1 ZONE SHUNTS AND BEEPER SOUNDS Page 10 ZONE SHUNT cont DISPLAY SHOWS ZONES DOORS DISARM HELP TO EXIT FROM THIS MODE PRESS THE NO BUTTON DISPLAY SHOWS DA
14. cedure on page 8 to stop the siren bell and clear the display AUDIBLE SILENCE To stop the siren bell from sounding ENTER YOUR USER CODE AND THEN PRESS THE 9 BUTTON The display will show AUDIBLE SILENCE and then return to date and time Page 7 ACKNOWLEDGE ALARMS This function is used to clear the display of flashing messages stop the beeper and in some systems silence the siren bells ENTER USER CODE AND THEN PRESS THE 0 zero BUTTON DISPLAY SHOWS CLEAR MESSAGES THEN X ACCEPTED where X is the number of alarms accepted and the system returns to the DISARM mode DISPLAY SHOWS DAY DATE TIME DOOR CHIME A chime feature is available on selected zones e g exit entry doors internal doors etc Whenever a door is opened the beeper will sound on the keypad for about 2 3 seconds To turn this feature on PRESS THE PART ARM 2 NIGHT BUTTON TWICE IN 3 SECONDS The display will periodically show the message CHIME IS ON on the lower line To turn this feature off PRESS THE PART ARM 2 NIGHT BUTTON TWICE IN 3 SECONDS and the message will disappear Page 8 HELP This function is used to assist users who know their access code but have forgotten or are unsure of which function button to press ENTER USER CODE AND THEN PRESS THE HELP BUTTON DISPLAY SHOWS SELECT AN OPTION AND THEN THE FIRST OPTION ALLOWED TO THAT USER e g DISARM Code DISARM or CLEAR MESSAGES Code 0 et
15. code and the printer will now provide a complete listing of user options names and id s Page 25 EDITING USER NAMES If you enter the wrong character s you can correct the error as follows PRESS SHIFT BUTTON until the cursor is pointing up DISPLAY SHOWS PRESS YES BUTTON to move cursor forward right or PRESS BACKSPACE BUTTON to move the cursor backward left until it is flashing over the character to be deleted PRESS and hold the SHIFT BUTTON for about one second to delete the unwanted character from the display If you find that you are deleting more than you intended you are holding the SHIFT BUTTON down for too long You may find it easier to delete the entire name and start again ENTER CORRECT CHARACTER S see page 23 and notice that the text to the right of the cursor will move ahead PRESS SHIFT BUTTON IF NECESSARY to return cursor to the up position AND PRESS RETURN BUTTON to store name Page 26 USER SET OWN ID This function allows a general user to select their own code rather than use the code given by the Master user The general user now has an absolutely confidential code The Master user must first authorize the use of this option and assign a temporary code to the general user This function can only be used once otherwise the Master user must reset the option ENTER USER CODE THEN PRESS SHIFT BUTTON AND THEN THE zero
16. options it must be done by a user lower in number than yourself ENTER USER NUMBER AND PRESS RETURN BUTTON DISPLAY SHOWS DISARM NO PRESS NO BUTTON if no and the selected user will not be allowed to disarm the system or PRESS YES BUTTON if yes and the DISPLAY Page 21 SETTING USER OPTIONS cont CHANGES TO DISARM YES The selected user will now be allowed to disarm the system All options available to the Master user will be consec utively listed By pressing YES or NO you can allow or deny access to each item of the list for that selected user The display then increments to the next user Hint You can step ahead to the next choice by pressing the DISARM button or you can step back to the previous choice by pressing the PART ARM 1 EVENING button In a similar manner you can use the DISARM and PART ARM 1 EVENING buttons to increment or decrement the user number instead of entering a numeric value WHEN ALL CHOICES HAVE BEEN MADE PRESS THE RETURN BUTTON DISPLAY SHOWS ENTER USER NO X NAME or User No X where X is one higher than the previous user number At this point you may continue to enter the options for the rest of the users or you may PRESS NO BUTTON to exit from this option DISPLAY SHOWS IDS OPTIONS NAMES DISARM PART2 HELP PRESS NO BUTTON twice to exit to DISARM mode Page 22 SETTING USER NAMES This option allows
17. ounds If by accident an alarm Page 5 FULL ARM cont activation occurs during the arming procedure the keypad may beep and the bell siren may sound If this happens enter your user code and then press the 9 button This may silence the bell siren if you have been given this option Follow the DISARM AN AREA procedure on page 2 to disarm the area and to also shut off the alarm bell siren if the 9 button did not work Details of the accidental alarm condition will then be flashed on the lower line of the display e g DAY DATE TIME INTRUDER ALARM alternating with ZONE DESCRIPTION or DAY DATE TIME IMPROPER CLOSING alternating with ZONE DESCRIPTION Enter your user code and then press the O button This will clear the display Press the button to display open zones and close as necessary Repeat the FULL ARM procedure as above Page 6 ALARMS If an ALARM or ALERT condition occurs during the disarmed period e g a fire door is opened the keypad may beep the siren bell may sound and the display will flash the relevant messages e g DAY DATE TIME FIRE DOOR OPENED or DAY DATE TIME INTRUDER ALARM or DAY DATE TIME ID SECURITY ALERT Ifan ALARM or ALERT condition had occurred during the armed period then when the panel is disarmed the display will be flashing messages similar to those above Follow the AUDIBLE SILENCE procedure below to stop the siren bell or the ACKNOWLEDGE ALARMS pro
18. re April 2000 the panel requires a semi automatic hour change in the spring and fall If you have a panel with firmware produced after April 2000 the panel will automatically spring forward and fall back To determine which firmware you have select this function If nothing happens and you are returned back to date and time you have an automatic hour change panel If the panel displays HOUR CHANGE ON SUNDAY then you have the semi automatic panel On any day of the week prior to the Sunday changeover ENTER USER CODE PRESS SHIFT BUTTON AND THEN PRESS THE HELP BUTTON DISPLAY SHOWS HOUR CHANGE ON SUNDAY On Sunday at 2 00 AM the panel will automatically add or subtract one hour and cancel the message If the hour change is entered by mistake RE ENTER USER CODE PRESS SHIFT BUTTON AND THEN PRESS HELP BUTTON DISPLAY SHOWS CANCEL HOUR CHANGE and then returns to DAY DATE TIME This option has now been cancelled Page 15 SET TIME COMMANDS This function is used to examine and program the auto arm and auto disarm time tasks A number of the time tasks allow for Closing Warning and Auto Arming of the areas in a partitioned system as well as the Full Arming of the system This task will permit a closing warning to sound at a specific time during the day When the warning occurs a 10 minute timer is started the panel will beep and if the warning is not acknowledged within the time period the p
19. t to date and time As above press the f button to view the Area armed status followed by the Zone status Close or bypass the zones and repeat the procedure above DISARMING AN AREA PARTITION Enter the area only through the designated exit entry door and proceed directly to the keypad The entry beeper will be beeping to remind you to turn off the system ENTER USER CODE THEN PRESS THE DISARM AREA PART ARM 1 BUTTON THE KEYPAD WILL DISPLAY THE FIRST AVAILABLE AREA TO BE DISARMED DISPLAY SHOWS DISARM AREA X Area Number X IF THIS IS THE AREA YOU DESIRE PRESS THE YES BUTTON OTHERWISE PRESS THE NO Page 2 ARM DISARM AREAS 1 32 cont BUTTON UNTIL THE DESIRED AREA APPEARS PRESS THE YES BUTTON TO SELECT THE AREA Alternatively you may enter the area number and press the RETURN button IF THERE ARE NO MORE AREAS TO DISARM PRESS THE BUTTON TO EXIT DISPLAY SHOWS WAIT THEN AREA DISARMED IF THERE ARE MORE AREAS AVAILABLE FOR DISARMING DISPLAY WILL SHOW ARM AREA Y Area Number Y IF THERE ARE NO MORE AREAS TO DISARM PRESS THE BUTTON TO EXIT If the area you have selected is the last area in the list the keypad will auto exit DISPLAY WILL SHOW DAY DATE TIME ALARM ON ENTRY If too much time is taken to disarm the partition then a full alarm will occur When the partition is finally disarmed DISPLAY SHOWS DAY DATE TIME AND FLASHES SLOW ENTRY ALARM ALTERNAT
20. ted G Q W etc When the cursor is pointing up the number button or symbol below a button is chosen 2 5 ye x D 1 R DISARM y 2 HELP ZEN L NK M amp Cie 2 3 Os OE EA 5 6 B R Fa S S T i 7 8 N 9 J EER 7 SPA SHIFT RETURN Page 31 INDEX ACKNOWLEDGE ALARMS 8 ALARMS el Ph Nd att e as ees la a 7 ARM DISARM AREA 1 32 1 AUDIBLE SILENCE ss ER toe eg sg ee awe 7 BATTERY PROBLEM 9 BLOCK SHUNT SHUNT 10 11 CLEARING ALARMS 8 CLEAR SHUNTS seco ees bata ete 11 CODES 16 19 CORRECTING USER NAMES 25 DATE SV 13 DATE TIME Leaks 13 DAYLIGHT SAVING TIME CHANGE 14 DISARM sade Ging sews so ed 4 DOOR CHIME Se micas 8 EDITING USER NAMES 25 PAULUS Er de SS cee eee chi eine Sea 29 PULL ARM bias woke Se ER eg Phases dd 5 suna 9 HOUR CHANGE 14 RE gears ER 16 19 NAME ME sich ee
21. user 33 If you have turned on the DURESS feature the user code cannot begin with the same number as the duress number e g if DURESS uses 0 code user codes 0001 to 0999 are not allowed Page 19 REMOVING USER IDS If a user code is no longer necessary you may remove the code from the system To do this choose the SETTING USER IDS option see page 16 and select IDS DISPLAY SHOWS SET ID REMOVE ID DISARM HELP PRESS THE HELP BUTTON DISPLAY SHOWS ENTER USER NO X NAME or User No X ENTER USER NUMBER OR PRESS DISARM PART ARM 1 BUTTON TO SCROLL THROUGH LIST PRESS RETURN BUTTON TO SELECT A USER DISPLAY SHOWS AREA YOU SURE NAME or User No X IF THIS IS NOT THE CORRECT USER PRESS NO TO RETURN TO PREVIOUS MENU AND SELECT AGAIN IF THIS IS CORRECT PRESS YES TO REMOVE DISPLAY SHOWS ENTER USER NO X NAME or User No X PRESS NO FOUR TIMES TO EXIT TO DATE AND TIME Page 20 SETTING USER OPTIONS This option allows a Master user to assign operating options to each of the 248 general users ENTER MASTER USER CODE THEN PRESS THE SHIFT BUTTON AND THEN PRESS THE DISARM BUTTON DISPLAY SHOWS USER SETUP AND IN A MOMENT IDS OPTIONS NAMES DISARM PART2 HELP PRESS PART ARM 2 NIGHT BUTTON DISPLAY SHOWS ENTER USER NO 3 NAME or User No 3 Note that this user is one greater than your user number because you are not allowed to give yourself

Download Pdf Manuals