1. A TEMPEST lighting inc Tempest Product Support Step 1 Step 2 First contact your local Dealer for support Your dealer is best placed to respond quickly to your needs If your dealer is unable to answer your questions please contact our Sales Office Tempest Lighting Inc 13110 Saticoy Street North Hollywood CA 91605 USA Tel 1 818 787 8984 Fax 1 818 982 5582 support tempestlighting com Visit our web site for current information and specifications www tempestlighting com Blizzard Enclosure User Manual page 35 x TEMPEST lighting inc 9 Registration Filling out the registration form on the next page and sending it to the Tempest Lighting factory within 30 days of installation entitles you to the warranty cover specified in this manual It also enables us to notify you in case of important news or post sale information regarding the Blizzard Lighting Enclosure Blizzard Enclosure User Manual page 36 A TEMPEST lighting inc Blizzard Enclosure Registration Form Detach and mail fax to Tempest Lighting Inc 13110 Saticoy St N Hollywood CA 91605 Fax 1 818 982 5582 If a Tempest Representative has not inspected the installation please send photos showing installation Model NUMO Rien SrL NUM DON criniera ire edi ian PaO Kr ey NUMO T ill T E A RES Dealer Sold By EOCAUONT in Iena Date Purchased Contractor Installed By Date INStalleO iucienli ninni L
2. Do not routinely operate projector in full sun in hot weather The enclosure has not been designed to protect the projector in this condition Blizzard Enclosure User Manual page 30 6 amp TEMPEST lighting inc Routine Maintenance It is very important to perform routine maintenance on both the enclosure and the projector inside it Failure to do so may reduce lifetime for both the enclosure and the projector Note Maintenance schedules depend on location and environment The intervals given here are general minimum guidelines It is up to the user to judge whether maintenance should be carried out more frequently We recommend doing these tasks no less often than mentioned here Safety ahd As the enclosure is a powered unit with moving parts it is necessary to keep safety in mind while performing routine maintenance Although maintenance can be performed while the enclosure is powered it is safer to carry it out with the power disconnected with proper lockout and tag out procedures followed Be aware that once the enclosure has had power applied to it the fan will start to turn Make sure that your hands are clear of the fan before applying power to the enclosure Only authorized personnel should perform maintenance on the enclosure or projector Do not service the unit in the rain or other adverse weather conditions snow sleet high winds etc Inspection Checklist Every Three 3 Months IIo
3. 2 Data 3 Data DMX THRU there are two DMX pass through terminals one for a fixture inside the enclosure the other to run to the next DMX device in the network Pinout 1 Ground 2 Data 3 Data Blizzard Enclosure User Manual page 39 x TEMPEST lighting inc DEC3 Control Introduction Tempest Lighting and Projector Enclosures have been in daily use around the world for almost a decade Tempest enclosures protect expensive and delicate equipment in all climates maintaining a comfortable operating temperature and preventing condensation the real outdoor enemy DEC3 that s Digital Enclosure Control third Generation is the brain of your Tempest enclosure It will maintain the internal environment in a comfortable temperature and humidity range and prevent condensation the real equipment killer DEC3 monitors internal temperature humidity and lamp current at all times and uses this information to control its lamp relay fan s and heater s It can report back over the DMX cable using the RDM protocol Remote Device Management if desired Unless otherwise specified this version of the user guide refers to DEC3 units fitted with software version 2 1 or later So what does DEC3 actually DO This schematic DEC3 is the brains of the operation here s a layout shows the relationship between DEC3 s functional DMX RDM red dedi x elements Passthrough asstnroug Th vi to Projector o
4. Power In Ground No Connection p 110 Live Power In Ground SOIS I O O O 5 D O Ground Ground REMOVE LINKS Note terminals shown with gray text descriptors are factory wired and should not be changed Only terminals shown with descriptors in black bold font are for installer use Blizzard Enclosure User Manual page 38 x TEMPEST lighting inc DEC3 normally ships from the factory with power terminal links inserted for a common electrical supply to feed the enclosure and the projector fixture inside it If you prefer to feed the enclosure and projector separately remove the terminal links as indicated before connecting to mains power Use a small flat bladed screwdriver to remove the link snap off the unneeded section and replace carefully When splitting the feeders we strongly recommend feeding both supplies from the same phase and at the same supply voltage 3 1 DMX Connections DMX refers to USITT DMX512 a commonly used control protocol in the entertainment industry running over RS485 Consult USITT DMX installation guidelines when laying out a system or consult a qualified DMX system integrator Note that DMX is optional in many applications it is not required and need not be connected For more information see DEC3 Operating Modes in the next section DMX IN Connect incoming DMX to the 2 part 3 pin terminal on the DEC3 control circuit board so labeled Pinout 1 Ground
5. Summary Standalone 1 6 OFF Standalone no DMX RDM DMX RDM 2 ON 1 3 6 OFF DMX RDM Modes 1 3 support for remote monitoring DMX Connections DMX refers to USITT DMX512 a commonly used control protocol in the entertainment industry running over RS485 Consult USITT DMX installation guidelines when laying out a system or employ a qualified DMX system integrator Note that DMX is optional in many applications it is not required and need not be connected DMX IN Connect incoming DMX to the 2 part 3 pin terminal on the DEC3 control circuit board so labeled Pinout 1 Ground 2 Data 3 Data DMX THRU there are two DMX pass through terminals one for a fixture inside the enclosure the other to run to the next DMX device in the network Pinout same as DMX IN DMX Line Terminations DMX cable runs must be terminated at the far end of the cable run with a termination resistor as detailed in the DMX standard This is particularly important for satisfactory operation of DMX RDM installations The individual fixtures installed inside the Tempest enclosures must NOT be terminated It is recommended that any line termination is done using the 3 pin terminal connector fitted to the DEC3 control circuit board 1 Make sure that any DMX termination provided by the fixture inside your enclosure s is disabled 2 The LAST enclosure in the installed DMX daisy chain should have a DMX Termination fitted to one of the pass through DMX conne
6. allows system integrators to set up remote control and status monitoring of all attributes and sensors including e Temperature e Humidity e Lamp Current e Elapsed Lamp Hours e Lamp Relay Status e Fan Relay Status e Heater Relay Status e DMX Status e DMX Start Address e DMX Personality RDM Mode e Device Type e Device Label e Software Version Tempest Lighting warrants that its RDM products are compliant to the RDM standard but does not directly support RDM system integration Tempest Lighting will however provide introductions to qualified RDM system integrators for customers requiring assistance in this area Links are provided on the Tempest Lighting web site www tempestlighting com Blizzard Enclosure User Manual page 46 Control Interface Heater Fan On Relay Temp DMX E Lamp k UN LLI O LLJ H OROROORO Y A TEMPEST lighting inc The control interface features a 2 line display LED indicators and 4 cap sense control buttons LED Indicators Heater SHORT PULSE RED Indicates lamp is off and the heater is pulsing to prevent condensation inside the enclosure and projector light fixture This is normal operation when the lamp is off and the temperature range is above the bottom set limit ON RED Indicates heater is on due to temperature being below bottom temperature setting when lamp is off OFF indicates lamp is on and maintaining temperature above bottom l
7. significantly warmer than ambient HUMIDITY SET The humidity level above which the heater kicks in to remove humidity from incoming air default 80 permissible range 50 90 This setting should not normally be changed TEMP SET Set three temperature trigger points for Top Cutoff and Bottom temperatures TOP TEMP The desired upper temperature limit for normal operation default 40 C permissible range 35 45 C Blizzard Enclosure User Manual page 48 amp TEMPEST ad lighting inc When the DEC3 sees air above this temperature but below the additional Cutoff temperature see below it indicates a temperature error This is not dangerous but may reduce lamp life CUTOFF TEMP The desired upper temperature ABOVE the TOP TEMP setting at which the lamp relay is forced to open isolating the fixture projector power default 15 C permissible range 0 15 C To avoid nuisance tripping set this variable to the maximum and monitor actual temperatures in your normal operating conditions If your actual temperatures are running lower then you may reduce the cutoff temperature margin In hot climates it may be advisable to set both TOP TEMP and CUTOFF TEMP as high as possible BOTTOM TEMP The desired lower temperature limit for normal operation default 10 C permissible range 0 10 C Note that a higher BOTTOM TEMP may provide additional protection against condensation in some conditions but will consume more energy Therefore a lower se
8. the locknut provided Remove the projector clamp bars 4 Place the projector on the projector tray If hanging the projector upside down one person must hold the projector in position while another person secures the projector clamp bars in place 5 Replace the projector clamp bars with the rubber pads pressing firmly onto the projector cover and tighet the nuts above and below each end of each projector clamp 6 Ensure that the projector is securely held before proceeding further Note You can still adjust the projector pan and tilt by loosening the projector clamp adjusting the projector feet then re tightening the projector clamp to hold the projector firmly in place Note BABY BLIZZARD is equipped with a load strap to secure the projector in place Projector L fast Clamp ae Ly Rubber Pad Threaded Rod i Lock Nut Projector Tray 7 Connectthe projector power cable to the projector and plug into the receptacle provided inside the enclosure International Versions IN part suffix are equipped with CE17 16amp 2P E receptacles US Versions US part suffix are equipped with NEMA L6 20 receptacles 8 Connect projector signal cables 9 Tie down any cables away from the exhaust fan 10 Power up the projector check functions and adjust focus 11 Replace the enclosure cover 12 Make sure that all latches are securely fastened The latches are adjustable and should be ch
9. to control the projector power over DMX DMX Terminations Pinout 1 Ground 2 Data 3 Data The picture shows the 4 DMX connections on the controller The incoming DMX feed should always be wired to DMX IN are j 1 If the enclosed projector shares the DMX signal the projector s DMX IN should be wired from connection 2 and its DMX OUT wired to connection 3 Connection 4 will then be the DMX OUT for the enclosure If the enclosed DMX OUT to DMX IN from next DMX device outside world projector does not use the DMX connection then DMX connection 2 on the controller becomes the DMX OUT for the enclosure DMX cable runs must be terminated at the far end of the cable run with a termination resistor as detailed in the DMX512 standard The individual projectors installed inside the Tempest enclosures must NOT be terminated It is recommended that any line termination is done using the 3 pin terminal connector fitted to the DEC3 2 control circuit board Blizzard Enclosure User Manual page 21 x A TEMPEST lighting inc RDM Connections RDM refers to ANSI E1 20 a control protocol in the entertainment industry gaining popularity and essentially an extension of DMX51 2 The use of RDM is optional and uses the same RS485 cable connection as DMX51 2 so no additional wiring is required It is the responsibility of the user to ensure that any DMX splitters or other routing devices use
10. to crimp the fan cable 6 Feed the hose through the wall or ceiling to a suitable location and screw in place This will normally be either in a large ceiling void or in a remote location with access to outside air 7 DO NOT EXTEND the hose beyond its 25 7 6m length It has been tested at this length and extending it further may reduce cooling efficacy inside the enclosure Blizzard Enclosure User Manual page 12 g amp TEMPEST Wiring Electrical Preparation All electrical work must be carried out by a properly licensed electrician Failure to observe this point will void the factory warranty for the Tempest Enclosure and possibly the projector projector Before starting work switch off power to the branch circuit carefully following lockout and tag out procedures Failure to do so could cause serious injury or death Two or three electrical junction boxes will be required within a short distance of the Blizzard enclosure for e AC Supply wiring Projector e AC Supply Wiring Enclosure Fan may be combined with projector power feed if desired e Projector picture signal wiring Your Blizzard enclosure is supplied fitted with two cable entry points suitable for flexible conduit fittings US size international 20mm Note the locations of the cable entry fittings Power Cable Signal Cable Entry on the rear panel Entry All junction boxes must be installed in accordance with local electrical codes and
11. 2 runs the fans to cool it down In cold conditions DEC3 2 will run the heater as required to maintain the bottom set temperature Thus DEC3 2 maintains a comfortable operating temperature inside the enclosure and prevents damage from condensation Users all over the world have found that Tempest enclosures provide an optimal environment for expensive and delicate equipment in every climate type And while doing all of this DEC3 2 can tell you what s happening over your RDM network a real boon in larger installations You may also use RDM to configure your Tempest installation remotely using an appropriate RDM front end Default Operation In most lighting and in almost all projector enclosure applications DEC3 2 will work just fine with its factory default settings You do not need to do anything other than connect power and switch on We call this Basic mode and it will apply to most installations If your needs are more complex read on If not you can skip to the Power Connections section below Operating Modes DEC3 2 may be run in one of three basic operating configurations with a fourth configuration for test and service use by trained personnel only In the RDM context these configurations are the Blizzard Enclosure User Manual page 17 TEMPEST lighting inc device s DMX PERSONALITY The DEC3 2 mode or personality may be configured form the Front Panel or by using an RDM control In all configurati
12. 8 electrical and UL 50 environmental as NEMA 3R enclosures for use in the United States and Canada This declaration is made by the manufacturer Tempest Lighting Inc 13110 Saticoy Street Unit C North Hollywood CA 91605 USA This declaration is based on tests that were conducted on the submitted samples of the above mentioned products Listing Report No 3198609LAX 001a refers Dated Decelntfer f 2th 2010 Signature HENGI Lu Tempest Lighting Inc Tempest Lighting Inc 13110 Saticoy Street North Hollywood CA 91605 USA f TEMPEST www tempestlighting com info tempestlighting com lighting in t 1 818 787 8984 f 1 818 982 5582 Blizzard Enclosure User Manual page 3 x A TEMPEST lighting inc Table of Contents Topic Section 111 010 0 6 0 BRR RR EI Enclosure DIMENSIONS sassari 1 1 Maximum Projector Dimensions and PoWer 1 2 INSTALLATION E E elena coniare rit 2 Safety and Warnings 2 1 TOONS and EqUIPMEN ssiri cinnin E aa RANEE NANESENE EK NENE 2 2 MOUNTING the ENCIOSUF siria 2 3 Base up or Base down OperatioN ei 2 4 MOUNTING the Projector wax cadstevnnccdincceuadatareandonsnonbaoubautsmeubcorsie init 2 5 MIO iii ideare 3 Wiring for Fan Only VersSionS 3 2 DEC3 2 Versions Wiring and Control 3 3 Operation Fan Only VersSionS 5 Routine MACHAN osiensa E E OE 6 Troubleshooting sis
13. CULAR PURPOSE ARE HEREBY EXCLUDED AND DISCLAIMED C Seller will accept the return of Goods properly rejected under paragraph A above or as to which Notice of an alleged breach of Warranty has been timely given and such Goods may be returned to Seller freight prepaid but only upon Customer s receipt of Seller s written return material authorization RMA and shipping instructions The RMA shall be void if the Goods are not received within 45 days after issuance of the RMA No deduction or credit in respect of any rejected or returned Goods shall be taken until Customer has received Seller s further written deduction or credit authorization following Seller s inspection to confirm nonconformity or defect Seller will charge to Customer any and all costs incurred by Seller in connection with the handling shipping inspection and disposition of any returned Goods that are determined by Seller not to have been nonconforming upon Delivery or as to which the warranty hereunder is not applicable D UPON ANY PROPER RETURN PURSUANT TO PARAGRAPH C ABOVE WHETHER IN CONNECTION WITH A REJECTION OF GOODS OR AN ALLEGED BREACH OF WARRANTY AND BASED UPON THE CONDITIONS SET FORTH IN THIS PARAGRAPH 7 SELLER AGREES THAT IT WILL AS THE SOLE AND EXCLUSIVE REMEDY UNDER THE CONTRACT OR OTHERWISE FOR ANY NONCONFORMITY OR BREACH OF WARRANTY AND AT SELLER S SOLE ELECTION i REPAIR SUCH GOODS OR ii REPLACE SUCH GOODS Blizzard Enclosure User Manual page 34
14. D DMX Fail ON GREEN Good DMX or RDM data packet received Note that in Monitor Mode the DMX indicator will only be green when RDM packets are being received In this case a RED LED is not indicating DMX failure just that no data is being received from the RDM monitor Control Interface Operation The Control Interface is normally LOCKED To UNLOCK hold ESC and OK together for 5 seconds You are now in the CONTROL MENU y Mo LL A 2 LU ls A Use the arrow keys to scroll up and down the menu Press OK to enter a menu item then the arrow keys to set the item parameter or to scroll to the next menu level Use ESC to back up a level and OK to confirm settings To LOCK hold ESC for 5 seconds Menu will time out after ten minutes CONTROL MENU SET DMX ADDRESS in Monitor DMX or Service modes Select a DMX starting address in the range 001 to 510 1 Lamp Relay In Service Mode an addition two slots are available 2 Fan Relay 3 Heater Relay Note that the DMX control is designed using a SAFETY pile on Logic So the DMX input can only override automatic settings in a safe manner For example if the enclosure has switched off the lamp relay due to an over temperature condition the DMX input cannot switch it on if the fans are running because of Overtemp the DMX input cannot turn them off and so on SET DMX MODE From the Front Panel this menu item allows the user to check and if necessary change the R
15. DM mode BASIC Standalone operation no DMX RDM factory default MONITOR Standalone plus support for RDM remote configuration and monitoring CONTROL Monitor plus use of a single DMX address to control Lamp relay SERVICE Monitor plus use of three DMX slots to control Lamp heater and fan Important Please ensure that the DEC3 2 is NOT left in Service Mode Blizzard Enclosure User Manual page 26 a amp j TEMPEST lighting inc STATUS DISPLAY View current status information using the arrow keys to scroll through a Humidity relative humidity in b Firmware version c Lamp Hours elapsed d Current being drawn by projector light fixture in amps e PCB temperature f Air temperature in degrees C or F note that sensor is placed in the exhaust airflow in Tornado enclosures and may be higher than the temperature being seen by the fixture body or electronics RESET LAMP HOURS The lamp hour counter needs to be reset each time you change the lamp in the fixture projector Make this a part of your maintenance instructions HUMIDITY SET The humidity level above which the heater kicks in to remove humidity from incoming air default 80 permissible range 50 90 SET FAN OVERRUN The fan will continue to run for a time after the internal fixture has gone to standby This facility allows the heat built up in the fixture to dissipate before the DEC3 2 resumes normal maintenance of the enclosure default 5 minutes per
16. Enclosure User Manual page 32 x A TEMPEST lighting inc 7 Troubleshooting This is a guide to the general symptoms problems and solutions that may occur during the usage of your enclosure However it is important to remember that problems may occur within the projector itself and these must also be considered Projector does not have power Check power supply wiring and voltage Fan is not spinning Fan cords may have become disconnected Check connections between fan and cord Fan may be obstructed Shut off power to enclosure and check for obstructions Turn power back on to see if fan will start spinning If fan does not turn then enclosure is not receiving power Turn off all power and check wiring If the wiring is correct contact technical support Projector does not have power Check projector power switch If switch is on check wiring and supply switch circuit breaker Projector turns on and off repeatedly over short span of time Check that vent areas and airways are clear If so ambient temperature may be too high or projector may have internal problem Excessive water in enclosure Glass seal leak Repair with silicone sealant Door gaskets leak caused by separation Silicone piece back into place or replace section Blizzard Enclosure User Manual page 33 amp TEMPEST lighting inc 8 Limited Warranty INSPECTION WARRANTY RETURNS A Customer at its sole expense shall inspect all Goods promptly upo
17. Inc assumes no responsibility for damages or injury incurred by misuse or mishandling of product akd N 2 2 Do not attempt to install or operate the enclosure before fully reading and understanding this manual Never allow anyone who has not read this manual to open the enclosure or perform maintenance on the projector within Never leave the enclosure unattended when open Always make sure all bolts and latches are tight and safety locks are in place after performing any form of maintenance on the unit Do not open any electrical boxes until power has been shut off to all supply lines to the enclosure including the one powering the projector Do not open the enclosure in wet weather Tools and Equipment To install the enclosure you will need the following items O 2 Crescent wrench Phillips screwdriver Terminal screwdriver Proper wiring installation equipment for line power and signal wiring Any equipment listed in the projector manufacturer s projector specific installation directions Mounting the Blizzard Enclosure The Blizzard enclosure must be mounted on or under a solid structure rated for the weight of the enclosure the projector inside it and at least one person Snow if installed outside in cold regions the bottom of the Blizzard enclosure must be at least 2 60cm above maximum height of any snowfall or drifting snow subject to local conditions If snow is not a co
18. Lamp Relay has the useful attribute of enabling the user to remotely force a hard reset of the fixture by controlling power to it This mode is recommended for show control applications where it is desirable to have power control of the internal fixture and accidental loss of the DMX data is very unlikely to OCCUr To force a hard fixture reset take the enclosure s DMX channel to zero or any level below 25 allow time for the fixture s power supplies to fully discharge then restore the enclosure s DMX channel to full or a level above 75 This mode is intended for test and service use only giving the user direct control of the Lamp Relay fan and heater controls over three DMX slots Users may NOT override any of the controls in an unsafe direction for example if the DEC3 2 has determined the enclosure is over temperature and has switched off the power to the fixture the Lamp Relay may not be controlled by DMX In this sense DMX Blizzard Enclosure User Manual page 18 TEMPEST lighting inc piles on to DEC3 2 operation within defined safety limits However until such time as the temperature reaches the TOP limit the heater may be enabled and the fan disabled which is why the mode should only be used for Test and Service use by a trained technician DEC 3 2 Control Parameters DEC3 2 will run out of the box with its default parameter settings which equate to the fixed settings of its predec
19. Single Feed lt a gt N CS DA a T TS Q_ 230V Dual Feed PROJECTOR FAN PROJECTOR lighting inc Blizzard Enclosure User Manual page 14 A TEMPEST lighting inc 3 2 Wiring for DEC Versions These instructions are for the installation of Projector Enclosures featuring Tempest s DEC3 Digital Enclosure Control System DEC3 Your enclosure has DEC3 control if you see a control panel on the rear surface like this b Ww Lu OL lt gt rai Lid a IMPORTANT Blizzard enclosures manufactured from September 2011 ship with DEC3 2 control described in the following section For Blizzard enclosures manufactured before September 2011 with DEC3 control see the appendix at the end of this manual Blizzard Enclosure User Manual page 15 A TEMPEST lighting inc DEC 3 2 Control Introduction Tempest Lighting and Projector Enclosures have been in daily use around the world for almost a decade Tempest enclosures protect expensive and delicate equipment in all climates maintaining a comfortable operating temperature and preventing condensation the real outdoor enemy DEC3 2 that s Digital Enclosure Control third Generation revision 2 is the brain of your Tempest enclosure It will maintain the internal environment in a comfortable temperature and humidity range and prevent condensation the real equipment ki
20. TEMPEST lighting inc a User Manual and Installation Guide EMPEST ed September 2011 Blizzard Series Projector Enclosures DEC3 2 You can download a copy of this manual at Covers http www tempestlighting com products html blizzard e all Blizzard models with DEC 3 2 control system manufactured after Tempest Lighting Inc September 1 2011 13110 Saticoy Street AI E Iv Bl d Encl North Hollywood CA 91605 USA i RR EER E e Includes supplement covering DEC3 Tel 1 818 787 8984 Fax 1 818 982 5582 control enclosures manufactured info tempestlighting com prior to September 2011 In the interest of continuous product improvement the information in this document is subject to change without notice Neither Tempest Lighting Inc nor its representatives or agents may be held liable for expense or injury arising from it Tempest Lighting Inc All Rights Reserved Declaration of Conformity This is to certify that the following products 6500 IN 6505 IN 6510 IN 6515 IN 6550 IN 6555 IN 6556 IN 6560 IN 6565 IN 6566 IN Baby Blizzard force cooled 230V Baby Blizzard force cooled 230V Baby Blizzard DEC3 Enclosure Control 230V Baby Blizzard DEC3 Enclosure Control 230V Blizzard DEC3 Enclosure Control 230V Blizzard Stretch DEC3 Enclosure Control 230V Blizzard X Stretch DEC3 Enclosure Control 230V Blizzard Force cooled 230V Blizzard Stretch Force cooled 230V Blizzard X St
21. UO Oo Uo 0 Glass should be clean and free of cracks Enclosure should be free of debris both inside and out Bolts and tie down straps should be tight Door seals should be in good condition Check seals inside and out for gaps Fan should be functioning and not making excessive noise Intake filter should be clean Air Filter Every Three 3 Months Blizzard Enclosure User Manual The air filter from the intake vent on front of enclosure back on 6550 6560 should be removed and cleaned ona regular basis To remove filter pull pull it directly out of the intake vent The filter can be cleaned by running water from a hose and do not require any special solution To reinstall push filter back into Velcro on the bottom of the intake vent Filter should be flush with bottom of vent x A TEMPEST lighting inc Case As Needed The outside of the case should be cleaned as needed The case should be cleaned with a wet cloth and mild detergent if necessary Do not use a direct spray from a hose to clean the case Window As Needed Clean using a proprietary glass cleaning solution or a mild detergent and wipe dry Use only soft lint free cloths for glass cleaning Never use an abrasive cleaner Projector Review the manufacturer s instructions for proper maintenance of your projector projector Remember the enclosure simply protects the equipment inside it and is not a substitute for regular maintenance Blizzard
22. actory default Tempest Enclosures are normally supplied wired for common electrical supply for the enclosure DEC3 2 and the projector light fixture to be enclosed Connect incoming power to the terminals labeled MAINS E Earth Ground L Live N Neutral Split Feed Operation Split Feed allows you to run the projector light fixture independently of the enclosure The enclosure must be powered 24 7 DEC3 2 normally ships from the factory with circuit card power links in place for a common electrical supply to feed the enclosure and the projector fixture inside it x To feed the enclosure and projector separately you will need to remove the bridging links on the controller circuit board as shown in the illustration before connecting to mains power Use a pair of small side cutters to cut the bridging links from the circuit board taking care to not damage any tracks on the card When splitting the feeders we strongly recommend feeding both supplies from the same phase and at the OOS OBOE i a same supply voltage Feeds must be adequately dimensioned and fused for the loads used Connect incoming enclosure power to the terminals labeled MAINS This supply MUST be maintained 24 7 E Earth Ground L Live N Neutral Connect incoming projector power to the terminals labeled SPLIT E Earth Ground L Live N Neutral Blizzard Enclosure User Manual page 23 J TEMPEST lighting inc Important RDM a
23. ce it as desired but should establish before doing so the actual operating temperatures experienced in hot weather before doing so to avoid nuisance tripping Bottom Set Range 0 10 C Default 10 C The temperature maintained by the heater in cold conditions Most equipment manufacturers recommend a minimum Blizzard Enclosure User Manual page 43 Humidity DMX Set Lamp Hours x A TEMPEST lighting inc operating temperature of 0 C and users may set it lower than the default if desired Range 50 90 Default 80 The threshold at which incoming air is more aggressively heated to remove moisture This parameter will not normally require adjustment Range 001 510 Default 001 Sets the DMX address for the lamp relay control In the DMX RDM service mode the subsequent two DMX slots control fan and heater respectively Default 0000 DEC3 counts the hours your projector fixture lamp is on and can report it both on the user interface display and over RDM Remember to reset to 0 when changing lamps This is provided to allow lamp hours monitoring on devices such as Video Projectors and certain moving lights that have no native RDM or DMX support Blizzard Enclosure User Manual page 44 x A TEMPEST lighting inc Setup and Connections Operating Mode Setup Your DEC3 will normally be factory set to the operating mode you specified in your order Operating Mode DIP Switch Settings Mode DIPswitch Settings Mode
24. cm 10 25cm 24 61cm 26 66cm 77 b 35kg 6555 US Blizzard Stretch DEC3 Enclosure Control 120V 41 104cm 45 114cm 16 41cm 12 30cm 35 89cm 26 66cm 971b 44kg 6555 IN Blizzard Stretch DEC3 Enclosure Control 230V 41 104cm 45 114cm 16 41cm 12 30cm 35 89cm 26 66cm 971b 44kg 6556 US Blizzard X Stretch DEC3 Enclosure Control 120V 49 124cm 51 130cm 16 41cm 12 30cm 42 107cm 26 66cm 1061b 48kg 6556 IN Blizzard X Stretch DEC3 Enclosure Control 230V 49 124cm 51 130cm 16 41cm 12 30cm 42 107cm 26 66cm 1061b 48kg 6560 US Blizzard Force cooled 120V 31 79cm 33 84cm 14 36cm 10 25cm 24 61cm 26 66cm 671b 30kg 6560 IN Blizzard Force cooled 230V 31 79cm 33 84cm 14 36cm 10 25cm 24 61cm 26 66cm 671b 30kg 6565 US Blizzard Stretch Force cooled 120V 41 104cm 45 114cm 16 41cm 12 30cm 35 89cm 26 66cm 871b 40kg 6565 IN Blizzard Stretch Force cooled 230V 41 104cm 45 114cm 16 41cm 12 30cm 35 89cm 26 66cm 871b 40kg 6566 US Blizzard X Stretch Force cooled 120V 49 124cm 51 130cm 16 41cm 12 30cm 42 107cm 26 66cm 961b 47kg 6566 IN Blizzard X Stretch Force cooled 230V 49 124cm 51 130cm 16 41cm 12 30cm 42 107cm 26 66cm 961b 47kg Maximum Projector Lamp Power 1 300 Watts Blizzard Enclosure User Manual page 7 2 2 1 amp TEMPEST lighting inc Installation Safety and Warnings These warnings are for your protection Failure to comply may result in serious injury or death Tempest Lighting
25. ctors Per the ANSI E1 11 standard the Terminator shall be 120 ohm 5 10 impedance placed between Data and Data We recommend minimum power rating of 0 6W for the resistor We recommend that the installer fit a label externally to say DMX Termination fitted internally Test 3 Switch mains power OFF to all enclosures 4 Before connecting the DMX line to your controller measure the impedance between Pin 2 Data and Pin 3 Data at the controller end Reading should be around 100 130 ohms Blizzard Enclosure User Manual page 45 x A TEMPEST lighting inc This test shows that you have a terminator in place and also that you have continuity of Data and Data between installed devices If the measured resistance is significantly less than 100 ohms say 40 80 ohms it suggests you may have multiple terminations in place Check that any terminator switches on light fixtures are OFF If impedance is very low check for wiring shorts RDM Connections RDM refers to ANSI E1 20 a control protocol in the entertainment industry gaining popularity and essentially an extension of DMX51 2 The use of RDM is optional but it does require a DMX512 cable connection Important RDM and RDM Integration RDM Remote Device Management is an ANSI standard that adds bidirectional discovery and status monitoring to a standard DMX network connection No additional wiring is required for RDM operation DEC3 s RDM implementation
26. d are rated for RDM as well as DMX use Power Connections IMPORTANT Tempest enclosures are supplied for either 120VAC 50 60Hz or 208 240VAC 50 60Hz operation Tempest Lighting is not liable for damage or failure to operate correctly due to connection to an inappropriate electrical supply ALL ELECTRICAL CONNECTIONS MUST BE UNDERTAKEN BY A QUALIFIED ELECTRICIAN IN COMPLIANCE WITH LOCAL NORMS AND STANDARDS Cut here for split supply operation i SOSSOOSCOGOOCODOOES T Fan 1 Bira rojector Fan2 receptacle Heater s Projector Supply Enclosure Supply split mode 100 250VAC 50 60Hz Note wire colors may differ depending on applicable electrical standards European wire colors are shown here MAKE SURE THAT TERMINAL SCREWS ARE FULLY BACKED OUT BEFORE INSERTING WIRES Blizzard Enclosure User Manual page 22 x TEMPEST lighting inc Split or Common Supply Wiring IMPORTANT Tempest enclosures with any generation of DEC control MUST be powered 24 7 in order to protect equipment from condensation and temperature extremes The AC power feed must be adequate and appropriately fused protected for the greater of the projector load see manufacturer s instructions and the Tempest enclosure see enclosure manual Since the enclosure heater s never operate when the projector lamp is on it is NOT necessary to rate the power service for the SUM of the enclosure and the projector Common Feed operation f
27. e lamp is off and the temperature range is above the bottom set limit Timing intervals may vary this is normal ON Green Indicates heater is on due to temperature being below bottom temperature setting when lamp is off OFF indicates lamp is on and maintaining temperature above bottom limit Fan SHORT PULSE Green The fan is moving a little air through the enclosure as part of the condensation prevention strategy The fan comes on for a few seconds approximately every 30 seconds ON Green Fan is running due to lamp being on or internal temperature exceeding top limit Lamp On ON Green Indicates current sensed on the lamp circuit greater than 0 5 amp this allows some current to be drawn for such things as fans and control electronics without the Lamp On indicator lighting When the Lamp On indicator is on the lamp counter is counting lamp life Lamp Relay ON Green Indicates lamp relay closed and power is available to the internal fixture OFF Indicates lamp relay open and power is removed from the internal fixture Temp ON Green The temperature is between Bottom and Top temperature settings ON Red The temperature is either a Below Bottom Setting b Above Top setting but below the Cutoff level FLASHING Red Temperature is above Cutoff level or below Bottom level Blizzard Enclosure User Manual page 25 TEMPEST lighting inc DMX Not used in BASIC Mode OFF No DMX received Basic Mode ON RE
28. ecked periodically since the rubber seal may compress slightly over time 13 For additional security use a bolt or padlock to lock one or more of the latches using the security ring provided Blizzard Enclosure User Manual page 11 TEMPEST lighting inc The latch tension is Insert a padlock in adjusted by turning the one or more m screw clockwise to security rings for tension anti clockwise to additional security loosen Installing the Blizzard Blimp Accessory If you ordered a Blimp kit with your Blizzard the installation is exactly the same except that the fan is remote from the enclosure and needs to be installed separately The Blimp kit provided with your enclosure comprises additional sound insulation inside the enclosure plus a remote fan kit Hose Ada ee mem eee eee eee eee oti Sound Insulation 25 7 6m Insulated Flexible Duct 1 Attach a Hose adapter plate to the exhaust air location on the right side of the rear panel using the four 8 32 screws provided Thread the fan cable through the padded hose provided using a fish tape Pass the fan cable through the hose adapter and connect to the FAN terminals inside the enclosure passing the fan cable through the rubber grommet in the side of the electrical cover 4 Attach one end of the hose to the hose adapter plate using one of the clamps provided Attach the other end to the Fan assembly in the same way taking care not
29. er a menu item then the arrow keys to set _ gI LLI gt LLI _ the item parameter or to scroll to the next menu level OROROORO Depending on the Operating Mode 9 Use ESC to back up a level and OK to confirm settings CONTROL MENU DMX SET if DMX RDM mode 2 or 3 is selected selected and present status DEC3 s 1 display shows you temperature Select a DMX starting address in the range 001 to 510 humidity DMX address and a 1 Lamp Relay selection of error and status ee messages In RDM Mode 3 an addition two slots are required 2 Fan Relay 3 Heater Relay Note that the DMX control is designed using a SAFETY pile on Logic In other words the DMxX input can only override automatic settings in a safe manner For example if the enclosure has switched off the lamp relay due to an over temperature condition the DMX input cannot switch it on if the fans are running because of Overtemp the DMX input cannot turn them off and so on The DMX SET menu can be ignored if the DEC3 is in Standalone or DMX RDM Mode 1 RDM Monitor mode SET LAMP HOURS TO 0 The lamp hour counter needs to be reset each time you change the lamp in the fixture projector Make this a part of your maintenance instructions STATUS DISPLAY View Temperature in Celsius and Relative Humidity in inside the enclosure Note that in Tornado moving light enclosures the temp humidity sensor is located in the exhaust airflow which may be
30. essor DECS 1 and 2 Temperature Humidity DMX Address Fan Overrun Blizzard Enclosure User Manual Top Set Cutoff Temp Bottom Set Range 35 45 C Default 40 C Most manufacturers recommend a max temperature for their equipment of 40 C though this does vary When DEC3 2 senses a temperature higher than Top Set it indicates an overtemp condition as a warning NOTE in moving light enclosures the thermal sensor is necessarily placed in the exhaust air path which will be higher sometimes a lot higher than the actual fixture ambient This needs to be kept in mind when adjusting temperature settings Range 0 15 C Default 15 C This is a setting above the Top Set temperature that determines the temperature at which the lamp relay is opened cutting off power from the fixture projector User may reduce it as desired but should establish before doing so the actual operating temperatures experienced in hot weather before doing so to avoid nuisance tripping Range 0 10 C Default 10 C The temperature maintained by the heater in cold conditions Most equipment manufacturers recommend a minimum operating temperature of 0 C and users may set it lower than the default if desired Range 50 90 Default 80 The threshold at which incoming air is more aggressively heated to remove moisture Range 001 510 Default 001 Sets the DMX address for the lamp relay control In the DMX RDM service mode the subseq
31. g inc DEC3 2 s mission is to maintain temperature and humidity inside the enclosure within determined bounds and to prevent condensation particularly overnight dew formation inside the equipment housed Condensation is fatal to electronic equipment particularly in polluted areas or saline environments where it brings not only rust and short circuits but also a steady buildup of mineral and or salt deposits Incidentally condensation is very hard to control with air conditioning type systems which is why we don t use them Broadly speaking DEC3 2 s function depends on whether the fixture projector lamp is on or off Lamp ON When the projector fixture is running the heat from the lamp takes care of humidity and DEC3 2 runs the enclosure s fan s to change its air every couple of seconds ensuring high velocity forced air cooling while the lamp is on Lamp OFF When the lamp is off DEC3 2 senses temperature and humidity and controls its fan s and heater s accordingly When conditions are within normal bounds between top and bottom temperature settings and below the humidity threshold see below DEC3 2 pulses the heater at a low level to dry the air and eliminate condensation and runs the fans to change the enclosure air every 30 seconds or so We call this pulse mode and it is the key to preventing damaging condensation inside your equipment If the temperature rises above the top set limit see below DEC3
32. i 7 VEE E A E E E A E 0 8 Redis TA Oee rA e EE E E 9 DEC3 Control for enclosures manufactured before September 201 1 Appendix Blizzard Enclosure User Manual page 4 TEMPEST lighting inc 1 Introduction The Blizzard Projector Enclosure Family Thank you for purchasing the Blizzard digital projector enclosure It will serve you for many years protecting your 5 15 000 ANSI Lumen projectors from the elements Although primarily intended for outdoor environments the design of the Blizzard is such that it can satisfy many other needs Not only will it protect against hostile outdoor conditions but also against particulate smoke and other indoor conditions that can shorten the life of your digital projector In addition you may specify a Blimp option with soundproofing and a remote fan for silent operation in theatres and classrooms Products Covered by this Manual 6500 Baby Blizzard Force cooled 6505 Baby Blizzard Force cooled Low noise 6510 Baby Blizzard DEC 3 2 6515 Baby Blizzard DEC3 2 Low noise 6550 Blizzard DEC3 2 Enclosure Control 6555 Blizzard Stretch DEC3 2 Enclosure Control 6556 Blizzard X Stretch DEC3 Enclosure Control 6560 Blizzard Force cooled 6565 Blizzard Stretch Force cooled 6566 Blizzard X Stretch Force cooled 6590 BK Blizzard Remote Fan Soundproofing Kit 6590 BK2 Stretch Blizzard Remote Fan Soundproofing Kit Notes Part suffix US for North American electrical system
33. imit Fan SHORT PULSE RED The fan is moving a little air through the enclosure as part of the condensation prevention strategy The fan comes on for a few seconds approximately every 30 seconds ON RED Indicates fan is running due to lamp being on or internal temperature exceeding top limit Lamp Relay ON RED Indicates lamp relay closed and power is available to the internal fixture projector OFF Indicates lamp relay open and power is removed from the internal fixture Lamp On ON RED Indicates current sensed on the lamp circuit greater than 1 amp this allows some current to be drawn for such things as fans and control electronics without the Lamp On indicator lighting When the Lamp On indicator is on the lamp counter is counting lamp life Temp ON GREEN The temperature is between Bottom and Top temperature settings FLASHING RED The temperature is above Top setting but has not yet reached the Cutoff level ON RED Temperature is above Cutoff level or below Bottom level DMX only used when DMX RDM setting is in effect ON RED DMX error Blizzard Enclosure User Manual page 47 A TEMPEST lighting inc ON GREEN Good DMX or RDM data packet received Control Interface Operation The Control Interface is normally LOCKED To UNLOCK touch ESC and OK together for 5 seconds ee a tee You are now in the CONTROL MENU Use the arrow keys to scroll up and down the menu Lamp Use OK to ent
34. jector fixture is running the heat from the lamp takes care of humidity and DEC3 runs the enclosure s fan s to change its air every few seconds ensuring minimal temperature rise above outside ambient Lamp OFF When the lamp is off DEC3 senses temperature and humidity and controls its fan s and heater s accordingly When conditions are within normal bounds between top and bottom temperature settings and below the humidity threshold see below DEC3 pulses the heater at a low level to dry the air and eliminate condensation and runs the fans to change the enclosure air every 30 seconds or so We call this pulse mode and it is the key to preventing damaging condensation inside your equipment If the temperature rises above the top set limit see below DEC3 runs the fans to cool it down In cold conditions DEC3 will run the heater as required to maintain the bottom set temperature Thus DEC3 maintains a comfortable operating temperature inside the enclosure and prevents damage from condensation Users all over the world have found that Tempest enclosures provide an optimal environment for expensive and delicate equipment in every climate type And while doing all of this DEC3 can tell you what s happening over your RDM network a real boon in larger installations Blizzard Enclosure User Manual page 41 TEMPEST lighting inc Operating Modes DEC3 may be run in one of three basic operating configuration
35. ll configurations RDM is an effective and powerful tool for commissioning and monitoring an installation particularly in large systems For further guidance we recommend you consult a qualified RDM system integrator If you don t have one in your neighborhood go to www tempestlighting com and click on the RDM and RDM Integration bug on the home and RBH Integration page for some useful contacts Tempest Lighting warrants DEC3 to be compliant with the RDM standard but is not an RDM systems integrator and can offer only basic guidance on RDM utilization DEC3 Control Parameters DEC3 will run out of the box with its default parameter settings which equate to the fixed settings of its predecessor DECs 1 and 2 Temperature Top Set Range 35 45 C Default 40 C Most manufacturers recommend a max temperature for their equipment of 40 C though this does vary When DEC3 senses a temperature higher than Top Set it indicates an overtemp condition as a warning NOTE in moving light enclosures the thermal sensor is necessarily placed in the exhaust air path which will be higher sometimes a lot higher than the actual fixture ambient This needs to be kept in mind when adjusting temperature settings Cutoff Temp Range 0 15 C Default 15 C This is a setting above the Top Set temperature that determines the temperature at which the lamp relay is opened cutting off power from the fixture projector The user may redu
36. ller DEC3 2 monitors internal temperature humidity and lamp current at all times and uses this information to control its lamp relay fan s and heater s It can report back over the DMX cable using the RDM protocol Remote Device Management if desired Unless otherwise specified this version of the user guide refers to DEC3 2 units fitted with software version 0 1 xxx or later So what does DEC3 2 actually DO This schematic shows The DEC3 2 Engine is the brains of the operation here s a layout the relationship between DEC3 2 s functional TI elements Er SI The power supply is universal 100 240V but peas bat aire fans and heaters are i o next enciosure DMX RDM Input TOF either 120V or 230VAC and must be so Sensor Block specified High quality high power Electro mechanical relays provide two pole power isolation for the enclosed the fixture projector in the event of an over Gui jajaa mm temperature condition oa 30A Triac 2 Pole 30A Lamp Relay Heaters Heater Switch Fans and heaters are switched using generously overrated Triac devices for maximum reliability 10A Power Feed 4 DMX connections are provided to facilitate field termination of DMX inputs and outputs via the enclosed fixture and the controller User Interface wn Lu Q S Lu is Blizzard Enclosure User Manual page 16 A TEMPEST lightin
37. missible range 0 15 minutes SET TEMP RANGES Set three temperature trigger points for Bottom Top and Cutoff temperatures TEMP BOTTOM The desired lower temperature limit for normal operation default 10 C permissible range 0 10 C TEMP TOP The desired upper temperature limit for normal operation default 40 C permissible range 35 45 C When the DEC3 2 sees air above this temperature but below the additional Cutoff temperature see below it indicates a temperature error This is not dangerous TEMP CUTOFF The desired upper temperature ABOVE the TOP TEMP setting at which the lamp relay is forced to open isolating the fixture projector power default 15 C permissible range 0 15 C To avoid nuisance tripping set this variable to the maximum and monitor actual temperatures in your normal operating conditions If your actual temperatures are Blizzard Enclosure User Manual page 27 TEMPEST lighting inc running lower then you may reduce the cutoff temperature margin In hot climates it may be advisable to set both TOP TEMP and CUTOFF TEMP as high as possible SET TEMP C OR F Choose to display temperature values in Celsius or Fahrenheit default Celsius RDM Monitoring and Configuration All the features accessible over the DEC3 2 control panel are also available over RDM Just how this information is displayed will depend on the RDM interface used The following screen shots were taken running the GetSet prog
38. n receipt and accept all Goods that conform to the specifications or catalog All claims for any alleged defect in or failure of the Goods or Seller s performance to conform to the Contract capable of discovery upon reasonable inspection must be set forth in a written rejection notice detailing the alleged non conformity and be received by Seller within thirty 30 calendar days of Customer s receipt of the Goods Failure by Customer to notify Seller of the alleged non conformity within thirty 30 days will be conclusive proof that the Goods have been received by Customer without defects or damage and in the quantities specified on the bill of lading and shall constitute an irrevocable acceptance of the Goods and a waiver of any such claim in connection with the Goods B Seller warrants to Customer only that the Goods will be free from defects in material and workmanship at the time of delivery and subject to the exceptions and conditions set forth below for the following period the Warranty Period twelve 12 months from the date of shipment by Seller Seller may provide additional years of warranty coverage beyond 12 month at the rate of 2 5 of the net sale price per year up to a total of four additional years coverage beyond the standard 12 month warranty period Seller will remedy a defect as set forth in paragraph 7 D below the Warranty The Warranty is subject to each of the following exceptions and conditions 1 Customer mu
39. nd RDM Integration DEC3 2 s RDM implementation allows system integrators to set up remote control and status monitoring of all attributes and sensors including e Relative Humidity e Air Temperature e PCB Temperature e Lamp Current e Elapsed Lamp Hours e Lamp Relay Status e Fan Relay Status e Heater Relay Status e DMX Status e DMX Start Address e DMX Personality RDM Mode e Device Type e Device Label e Software Version DMX RDM is an effective and powerful tool for commissioning and monitoring an Va installation particularly in large systems For further guidance we have one in your neighborhood go to www tempestlighting com and click on the RDM and RDM recommend you consult a qualified RDM system integrator If you don t Integration bug on the FAQ page for some useful contacts Tempest Lighting warrants DEC3 2 to be compliant with the RDM standard but is not an RDM systems integrator and can offer only basic guidance on RDM utilization Blizzard Enclosure User Manual page 24 amp TEMPEST lighting inc Control Interface The control interface features a 2 line display LED indicators and 4 sealed control buttons Relay Temp DMX Lamp lighting inc U LL oO gt LLI H a ul LED Indicators Heater SHORT PULSES Green Indicates lamp is off and the heater is pulsing to prevent condensation inside the enclosure and projector light fixture This is normal operation when th
40. nsideration then enclosure may sit on the ground as long as proper drainage is provided Blizzard Enclosure User Manual page 8 x A TEMPEST lighting inc LEAVE ADEQUATE CLEARANCE BEHIND ENCLOSURE FOR WIRING AND VENTILATION Tempest Lighting recommends the use of stainless steel mounting hardware The Blizzard enclosure is provided with a pair of Unistrut channels on the enclosure base for mounting to your structure You may use standard Unistrut accessories or purchase mounting kits from Tempest Lighting four kits are required per enclosure _ 4900 MB Stainless Steel Unistrut channel nut bolt and washer Four required per enclosure Mounting holes 0 532 13mm 4 places 4900 MC Stainless Steel Unistrut channel nut bolt and pipe clamp for pipes 1 5 38mm to 2 50mm OD Four required per enclosure 4925 MC Stainless Steel Unistrut channel nut bolt and pipe clamp for pipes 2 50mm to 2 5 64mm OD Four required per enclosure Blizzard and Stretch Blizzard Baby Blizzard Suggested layout for mounting plate using four Suggested layout for mounting plate using four 4900 MB kits 4900 MB kits 10 0 254mm 10 0 254mm Side 12 0 305mm Front Back 15 0 381mm Front Back Blizzard Enclosure User Manual page 9 amp TEMPEST lighting inc 2 4 Mounting Base down and Base up All Blizzard enclosures are designed to be mounted base d
41. ocation Installed ciccia i III iii Company Organization Blizzard Enclosure User Manual page 37 x A TEMPEST lighting inc Appendix DEC3 Control Enclosures manufactured before Sept 2011 IMPORTANT Tempest enclosures are supplied for either 120VAC 50 60Hz or 208 240VAC 50 60Hz operation Tempest Lighting is not liable for damage or failure to operate correctly due to connection to an inappropriate electrical supply N N M ALL ELECTRICAL CONNECTIONS MUST BE UNDERTAKEN BY A QUALIFIED ELECTRICIAN IN COMPLIANCE WTH LOCAL NORMS AND STANDARDS Split or Common Supply Wiring NOTE Your enclosure MUST run 24 7 in order to protect equipment from condensation and temperature extremes Tempest Enclosures are supplied wired for common electrical supply for the enclosure DEC3 and the projector light fixture to be enclosed Customers wishing to provide independent electrical feeds to the enclosure and the projector fixture must follow the instructions below Feeder Connections Common Feed Feeder Connections P Feeds es Live role Feed Neutral Projector Feed HE Live ida Feed Neutral Projector Feed Neutral Heater Neutral Heater Neutral Fan Neutral Fan Neutral Fan Neutral Fan Neutral Fan KSTSTSTS Neutral Fan Y Neutral Power In Neutral Enclosure Power In VCKOeNoO VG N No Connection Neutral Projector Power In Ol J KX 10 Live Projector Power In QUE ais LO Live Enclosure
42. ons the fixture inside the Tempest enclosure may also be an RDM enabled device Basic Mode Monitor Mode Control Mode Service Mode This is the way your DEC3 2 controller will normally ship from the factory It will be set up for standalone operation with settings that will be appropriate for most installations In most cases Basic Mode will work fine for you You only need to change it if you will be using DMX or RDM and if these terms are not familiar to you you probably won t or if you have to deal with extreme climate conditions You may set temperature and other parameters while using Basic Mode The enclosure operates independently and automatically requiring no user intervention Users may set parameters such as temperature and humidity thresholds and monitor sensor information and DEC status at the DEC3 2 using the display or remotely using RDM over a DMX512 network In this mode the DEC3 2 does not need to see any DMX to operate This mode has all of the Monitor Mode features plus control of the Lamp Relay using a single DMX slot at the address configured as the DEC3 2 DMX start address A DMX slot value level gt 75 will cause the fixture to be powered and less than 25 will disconnect the power form the fixture On DMX fail the Lamp Relay will default to power the fixture unless it detects a thermal condition that would cause it to isolate power from the fixture projector DMX control of the
43. own on a solid structure using Unistrut mounting hardware They may also be suspended from an overhang ceiling or truss using the same hardware Note that in this event it will be necessary to flip the projector image since the projector itself will be hanging upside down It s important to be sure that the projector to be used supports this feature usually referred to as Ceiling Mount mode before commencing installation Air vents for Base up operation When the Blizzard is used base up remove the front and back air vents invert and replace to prevent rainwater ingress Rear air exhaust vent inverted for base up operation Do the same with the front intake vent Dal IMPORTANT SAFETY NOTICE It is the responsibility of the installer to ensure that all mounting points are secure and conform to local safety regulations Tempest Lighting Inc accepts no responsibility for damage or injury arising from inappropriate or unsafe installation Blizzard Enclosure User Manual page 10 x A TEMPEST lighting inc 2 5 Mounting the Projector in the Blizzard Enclosure s3 If the Blizzard enclosure is suspended from a ceiling or overhang this must be done by two people 1 Find the best location for the two projector clamps avoiding contact with access doors vents and control on the projector top 2 Make sure that all four Projector clamp threaded rods are screwed into the projector tray and locked in place with
44. ptional A to aa DEC3 J op universal 90 260V enclosure Lamp but fans and heaters Current Sensor are either 120V or 230VAC and must be so specified 2 pole 25amp 240V lamp relay e A high quality 25amp 2 pole li electro mechanical 40amp Fan switch triac relay isolates fixture projector J 40amp Heater switch triac H Power Supply power in the event of an over temperature condition Temperature Sensor Fans and heaters are switched using generously overrated DMX RDM Input a 40amp Triac devices Humidity Sensor Or OAU E ene de reliability ro Two DMX outputs connect to the internal fixture if desired and on to A O other enclosures or DMX devices User Interface DEC3 s mission is to maintain temperature and humidity inside the enclosure within determined bounds and to prevent condensation particularly overnight dew formation inside the equipment housed Condensation is fatal to electronic equipment particularly in polluted areas or saline environments where it brings not only rust and short circuits but also a steady buildup of mineral and or salt deposits Incidentally condensation is very hard to control with air conditioning type systems which is why we don t use them Broadly speaking DEC3 s function depends on whether the fixture projector lamp is on or off Blizzard Enclosure User Manual page 40 x A TEMPEST lighting inc Lamp ON When the pro
45. r sources for the enclosure and the luminaire projector since the DMX slot may be used to isolate the projector when not in use without removing power from the enclosure This mode is recommended for show control applications where it is desirable to have power control of the internal fixture and accidental loss of the DMX data is very unlikely to occur In the absence of DMX the Lamp Relay defaults to ON All RDM functions are available for configuration and monitoring of the DEC3 DMX RDM Mode 3 Service Test This mode is intended for test and service use It gives the user direct control of the lamp fan and heater relays over DMX User may NOT override any of the relays in an unsafe direction for example if the DEC3 has determined the enclosure is over temperature and has switched off the lamp relay the relay may not be overridden ON by DMX In this sense DMX piles Blizzard Enclosure User Manual page 42 x A TEMPEST lighting inc on to DEC3 operation within defined safety limits However until such time as the temperature reaches the TOP limit the heater may be enabled and the fan disabled which is why the mode should only be used for Test and Service use If the DEC3 has been purchased with DMX RDM enabled it is possible to select the required mode 1 3 using RDM In the RDM context this is known as selecting the device s DMX PERSONALITY Setup of the DEC3 from the Front Panel is available in a
46. ram in Windows 7 and connecting to a DEC3 2 controller using a RDM TRI MK1 interface both from JESE Ltd jese co uk eto hem _ Unique ID Description w AC 00002748 DECHHAESZ Controller Femote Device Tempest Lighting Inc DECS ME Controller Software Version 00 12 Root and Sub Devices Click an Hem te Activate HEN THIET gwim 0120 0121 pie File Connection Options Tools Help DEC3 2 Test Unit Relative Humidity 40 0 1 Device c discovered in 0 3 seconds Normal Range Min Max 10 0 90 0 gt Sensor Relative Humidity Humidity Porameter Key Required Farannotor Supported Parameter Hanutacturer Parameter ESTA Reserved Parameter Supported Paramaters Parameter QUEUED_ MESSAGE STATUS MESSAGES STATUS IO DESCRIPTION VLE AR STATUS ID PARAME TER_DESCRIFTICOH DEVICE MODEL DESCRIPTION MAMUFALTURER_LADEL DEVICE LABEL OME PERSONALI Ok PERSONALI UE SCRIFTION DMX START_ADDAESS SLOT INFO SLOT DESCRIPTION DEFAULT SLOT WALLIE iii Show 100 Delta Range Min Max 49 6 50 4 Blizzard Enclosure User Manual This view shows a single DEC3 2 test unit that has been correctly discovered and labeled by the GetSet software suite and a log of RDM messages This RDM interface provides a graphic view of the various sensor functions supported by DEC3 2 humidity air temperature pcb temperature There is a grea
47. retch Force cooled 230V are in Compliance with the following standards or specifications according to the EMC Directive 89 336 EEC EN55015 EN61000 3 4 EN61000 3 5 EN61000 4 2 EN61000 4 3 EN61000 4 4 pr EN61000 4 5 EN61000 4 6 EN61000 4 8 EN61000 4 11 and are in compliance with the following standards or specifications according to the Low Voltage Directive 73 23 EEC EN60598 1 This declaration is made by the manufacturer Tempest Lighting Inc 13110 Saticoy Street Unit C North Hollywood CA 91605 USA This declaration is based on tests that were conducted on the submitted samples of the above mentioned products Detailed results can be referred to test repens CET TE200909 and LVT Te200909 Dated RINO 26 2009 Signature JW Salk La Tempest Lighting Inc amp TEMPEST Blizzard Enclosure User Manual page 2 This is to certify that the following products 6500 US Baby Blizzard force cooled 230V 6505 US Baby Blizzard force cooled 230V 6510 US Baby Blizzard DEC3 Enclosure Control 230V 6515 US Baby Blizzard DEC3 Enclosure Control 230V 6550 US Blizzard DEC3 Enclosure Control 230V 6555 US Blizzard Stretch DEC3 Enclosure Control 230V 6556 US Blizzard X Stretch DEC3 Enclosure Control 230V 6560 US Blizzard Force cooled 230V 6565 US Blizzard Stretch Force cooled 230V 6566 US Blizzard X Stretch Force cooled 230V Have been tested and approved to standards UL 50
48. s A fourth configuration is provided for test and service use Standalone The enclosure operates independently and automatically requiring no user intervention User may set parameters such as temperature and humidity thresholds and monitor sensor information and DEC status at the DEC3 user interface Standalone is the default DEC3 shipping mode unless specified otherwise at time of order DMX is not required or utilized DMX RDM Mode 1 RDM Monitor All of the Standalone features plus the ability to discover and monitor the DEC3 over a DMX512 connection using RDM In this mode the DEC3 does not need to see any DMX to operate The mode allows the use of RDM to set the various temperature thresholds and monitor the conditions inside the enclosure remotely The fixture inside the Tempest enclosure may also be an RDM enabled device DMX RDM Mode 2 DMX Enable All of the Standalone and RDM Monitor features plus the use of a single DMX address slot to control the Lamp Relay This means that the user is responsible for maintaining a DMX input with the slot as selected as the DMX START ADDRESS on the DEC3 high This slot level must be set greater than 50 at all times when the internal fixture is to be powered This has the useful attribute of enabling the user to remotely force a hard reset of the fixture by opening and then closing the Lamp Relay It also means that it is unnecessary to feed the enclosure with two powe
49. s Part suffix IN for European 230V electrical systems North American versions are 208VAV as standard 1 20VAC available to order Using This Manual Please read this manual in its entirety before starting work All the information contained is important and should be read carefully before proceeding Heed all warnings and advisories Icon Key Valuable information MW Electrical Warning aa Safety Information Blizzard Enclosure User Manual page 5 TEMPEST lighting inc 1 1 Dimensions and Weight Baby Blizzard 9 23cm a TE C Do not mount in areas l shaded gray 10 25 4cm Foos 2CM T lt 20 Sicm 15 38 1cm ee 22 55 9cm gt _ gt 26 66cm Enclosure Weight 29Ib 13kg 1 2 Maximum Projector Dimensions and Power 17 43cm 17 43cm Maximum Projector Power Standard Versions 700W Low Noise Versions 350W Blizzard Enclosure User Manual page 6 gt 4 TEMPEST lighting inc 1 1 Dimensions and Weight Blizzard and Stretch Blizzard C No attachment in ET 6 shaded areas 15 38 1cm 12 30 5cm fe 30 51cm 16 41cm B O O Maximum Projector Dimensions E F Model Description A B C D E F Weight 6550 US Blizzard DEC3 Enclosure Control 120V 31 79cm 33 84cm 14 36cm 10 25cm 24 61cm 26 66cm 77 b 35kg 6550 IN Blizzard DEC3 Enclosure Control 230V 31 79cm 33 84cm 14 36
50. should be located near the permanent installation of the enclosure Each junction box requires a length of flexible conduit long enough to reach from junction box to the enclosure conduit fittings Leave slack for positioning of enclosure and enough space behind the enclosure for ventilation The AC supply must be protected by a fuse or circuit breaker of a rating suitable for the projector For the DEC3 versions add max 550W load for the enclosure fan and heater The user may connect the fan and the projector to the same switched supply or run them separately according to need If run separately it is the user s responsibility to ensure that the fan is always running when the projector lamp is on Blizzard Enclosure User Manual page 13 x A TEMPEST 3 1 Fan Only Versions Remove the electrical cover inside the enclosure You will see the fan wires already terminated to the connector block on the rear panel Pass the AC feeder wires through the rear panel and terminate to the connector block using one of the wiring diagrams below Feed the projector power cable through the grommeted hole in the electrical cover and terminate as shown in the wiring diagrams below Replace the electrical cover taking care not to pinch any of the power wires Use the second cable entry to run projector signal and control cables to the projector as specified by the projector manufacturer Wiring Diagrams 120V Dual Feed 120V
51. st promptly and in all events within the Warranty Period notify Seller of any alleged defect in a written notice the Notice which shall set forth the quantity catalog number finish original purchase order number Seller s invoice number on which Goods were originally billed and a statement of the alleged defect along with digital photographs showing such defects where feasible 2 The Warranty shall not apply i to any claimed defect that was capable of discovery upon reasonable inspection and deemed to be waived under paragraph A above ii to any Goods that have been subject to misuse abnormal service or handling or altered or modified in design or construction iii to any Goods repaired or serviced by any person other than Seller s authorized service personnel or to Goods installed other than according to installation instructions or iv with respect to normal wear and tear 3 Seller makes no Warranty with respect to parts or components that are not the product of Seller and specifically makes no warranty whatsoever for equipment housed inside enclosure products manufactured by Seller 4 The Warranty is Seller s exclusive warranty with respect to the Goods Seller makes no warranties guarantees or representations express or implied to Customer except as set forth in this section ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR USE OR FOR A PARTI
52. t deal of variability in the way RDM interfaces handle generic and manufacturer specific information We recommend page 28 TEMPEST lighting inc asking your RDM interface vendor whether he has tested his interface with Tempest enclosures and all other RDM devices you plan to use on the same network Firmware Upgrade over RDM p m DEC3 2 firmware is Connection Options Tools Help d now field upgradeable using RDM A field upgrade requires a Device 544C 0000 2748 E il JESE RDM TRI MKI Firmware Upload interface to be CRE connected to the Manufacturer DMX network on DEC3 MK Controller Software version which the DEC3 2 00 12 is located and the File Select use of JESE GetSet software 0 Select a file to upload 1 Device discovered n 0 3 seconi Blizzard Enclosure User Manual page 29 5 x A TEMPEST lighting inc Operation Fan Only Versions While there are no specific operational actions required for normal use the following points should be kept in mind IFthefan and projector have been powered separately it is the responsibility of the user to ensure that the fan is running at all times when the projector lamp is on Unless the enclosure or projector is undergoing routine maintenance the enclosure should be closed and securely latched at all times Only authorized personnel should open the enclosure see maintenance warnings in the next chapter
53. tting is desirable provided the user is certain that no condensation is occurring RDM MODE SET The RDM Mode is normally set using RDM commands from a remote RDM control device to set the DMX PERSONALITY of the DEC3 From the DEC3 user interface this menu item allows the user to check and if necessary alter the RDM mode Please ensure that the DEC3 is NOT unintentionally left in Mode3 Service Test Blizzard Enclosure User Manual page 49
54. uent two DMX slots control fan and heater respectively Range 1 15 minutes Default 5 minutes This is the time that the enclosure fan s will run after the fixture projector lamp is turned off As a general rule the more powerful the lamp the longer the overrun should be to prevent overheating while the lamp cools down page 19 x A TEMPEST lighting inc Temp C F Default Celsius DEC3 2 displays temperatures in Celsius or Fahrenheit Lamp Hours Default 0000 DEC3 2 counts the hours your projector fixture lamp is on and can report it both on the user interface display and over RDM Remember to reset to 0 when changing lamps This is provided to allow lamp hours monitoring on devices such as Video Projectors that have no native RDM or DMX support Blizzard Enclosure User Manual page 20 TEMPEST lighting inc 4 Setup and Connections DMX Connections Most projector applications will NOT require DMX in which case you may skip this section DMX refers to USITT DMX512 a commonly used control protocol in the entertainment industry running over RS485 Consult USITT DMX installation guidelines when laying out a system or employ a qualified DMX system integrator Note that DMX is optional in many applications it is not required and need not be connected A DMX network will be required if a The projector inside the enclosure requires a DMX control signal b You wish to monitor the enclosure using RDM c You wish