1. Motor 115V COM 015 Motor 230V Symbols and Conventions The following chart is an illustrated glossary of the symbols that may be used in this manual or on the product The electrical warning indicates the presence of a potential hazard which could result in electrical shock CAUTION This symbol refers you to important operating and maintenance servicing instructions within the product Instruction Manual Failure to heed this information may present a risk of damage or injury to persons or equipment This symbol identifies a Protective Earth PE terminal which is provided for connection of the supply system s protective earth green or green yellow conductor EQUIPMENT DISPOSAL This equipment is marked with the crossed out wheeled bin symbol to indicate that this equipment must not be disposed of with unsorted waste Instead it s your responsibility to correctly dispose of your equipment at lifecycle end by handing it over to an authorized facility for separate collection and recycling It s also you responsibility to decontaminate the equipment in case of biological chemical and or radiological contamination so as to protect from health hazards the persons involved in the ae disposal and recycling of the equipment For more information about where you can drop off your waste equipment please contact your local dealer from whom you originally purchased this equipment By doing so you will help to conserve
2. natural and environmental resources and you will ensure that your equipment is recycled in a manner that protects human health Thank you Labnet International Inc 31 Mayfield Ave Edison NJ 08837 732 417 0700 F 732 417 1750 Labnet Email labnetinfo corning com www labnetinternational com Labnet International Inc Declaration of Conformity Number CE 00401 Labnet International Inc 31 Mayfield Ave Edison NJ 08837 USA Labnet International declares that the devices described below are in conformity with the EC directives listed In the event of unauthorized modification of any of the devices listed below this declaration becomes invalid Device Name Prism Mini Centrifuge Device Models Numbers C1801 C1801 230V EU C1801 230V UK Relevant EC Directives Low Voltage Directive 2006 95 EC Directive 2004 108 EC RoHS 2002 95 EC WEEE 2002 96 EC Harmonized Standards 61010 1 Issued 2001 EN 61010 2 020 2006 EN 61326 1 2006 Date May 1 2012 j pi 7 ot Labnet Product Line Manager Labnet International Inc LIMITED WARRANTY Labnet International Inc warrants that this product will be free from defects in material and workmanship for a period of two 2 years from date of purchase This warranty is valid only if the product is used for its intended purpose and within the guidelines specified in the supplied instruction manual Sh
3. the lid of the centrifuge No other controls are required To stop rotation press and release the tab on the front of the lid This will release the lid lock allowing the lid to self open and the rotor to come to a gradual stop Caution Do not attempt to open the lid or remove samples until the unit has come to a complete stop Once the lid has fully opened and the rotor has stopped samples may be removed from the rotor Safe operation of the centrifuge requires that the rotor be loaded in a balanced fashion Failure to load the rotor properly presents a hazardous condition and may damage the centrifuge Individual tubes strip tubes and or adapters must always be loaded symmetrically to ensure proper balance Never run the centrifuge with only one strip tube in place Equipment maintenance 1 Instructions specify inspection of any means of fixing the equipment to the mounting surface and the condition of the mounting surface itself 2 Instructions specify safeguards for the operator during cleaning 3 Inspection of the protective casing 4 Frequency of inspection and the method of replacement of BIOSEALS and other bio containment components 5 The instructions for use state the precautions when the materials to be used with a laboratory centrifuge are known to be toxic radioactive or contaminated with pathogenic micro organisms Rotors The centrifuge is supplied with two interchangeable quick release rotors No tools are required to excha
4. Prism Mini Centrifuge User Manual 96 ae 1801 C1801 230V EU C1801 230V UK Labnet International Inc Rev 1 April 2012 Intertek CE GFE M00401 General Information The Labnet Prism Mini Centrifuge is supplied with two rotors one for microtubes one for 0 2ml PCR strip tubes The 8 place rotor is designed to centrifuge up to eight individual 1 5 2 0ml plastic microcentrifuge tubes It will also accept 0 5ml and 0 4ml tubes with the adapters supplied with the unit Adapters are available separately for 0 2ml tubes The strip tube rotor is designed to centrifuge four 8 0 2ml strip tubes It will also accept up 32 individual 0 2ml tubes Both rotors are designed for applications requiring relatively low g forces such as microfiltration cell separation and quick spin downs from the walls of tubes Please read this manual thoroughly before attempting to operate the centrifuge Intended use of the equipment For Quick Spin down from Walls or Caps of Centrifuge Tubes Complete Set with Circular Fixed Angle Rotor and Strip Rotor Installation 1 Bench top area required for the clearance envelope for the intended use 2 Methods for leveling of the centrifuge 3 Instructions for site preparation Operation Before operating the centrifuge be sure that the power switch on the back of the unit is in the on position To begin a run simply close
5. ed warranties or the exclusion or limitation of incidental or consequential damages This warranty gives you specific legal rights You may have other rights which vary from state to state No individual may accept for or on behalf of Labnet International Inc any other obligation of liability or extend the period of this warranty Mail Warranty Registration to Register online at Labnet International Inc www labnetinternational com 31 Mayfield Ave Edison NJ 08837 3 lt cut along the dotted line To validate the warranty complete and return this card within 10 days Model Serial No Date Tested Date Rec d PO Name Title Phone Institution Address City State _____ Zip Postal Code Country Purchased from distributor How would you rate the quality of this product Excellent O Fair J Poor What feature s on this product made you purchase it What feature s would you change to improve the performance of this product Labnet 31 Mayfield Avenue Edison NJ 08837 732 417 0700 f 732 417 1750 Labnet International Inc
6. nge the rotors or attach them to the motor shaft The rotors can be easily exchanged with one hand by way of the quick release system Removal of the rotors is done by placing your thumb on top of the motor shaft and lifting up with two fingers under the rotor Place the other rotor into position on the motor shaft and snap in 8 place tube rotor and 4 place strip rotor Safety Precautions NEVER use the centrifuge in any manner not specified in these instructions NEVER operate the centrifuge without a rotor properly attached to the shaft NEVER fill tubes while they are in the rotor Liquid spillage may harm unit NEVER put hands in the rotor area unless the rotor is completely stopped NEVER move the centrifuge while the rotor is spinning NEVER use solvents or flammables near this or other electrical equipment NEVER centrifuge flammable explosive or corrosive materials NEVER centrifuge hazardous materials outside of a hood or proper containment facility ALWAYS load the rotor symmetrically Each tube should be counterbalanced by another tube Weight of individual tubes may not exceed of 3 0g ALWAYS locate the centrifuge within easy access to an electrical outlet ALWAYS use only microcentrifuge tubes made from plastic and designed to withstand centrifugal forces of at least 2 000 xg Cleaning Before using any cleaning or decontamination methods except those recommended by the manufacturer check with the manufacturer that the propo
7. ould this product require service contact Labnet International Inc s Service department at 732 417 0700 to receive a return authorization number and shipping instructions Products received without proper authorization will be returned All items returned for service should be sent postage prepaid in the original packaging or other suitable carton padded to avoid damage Labnet International Inc will not be responsible for damage incurred by improper packaging Labnet International Inc may elect for onsite service for larger equipment This warranty does not cover damage caused by accident neglect misuse improper service natural forces or other causes not arising from defects in original material or workmanship This warranty does not cover motor brushes fuses light bulbs batteries or damage to paint or finish Claims for transit damage should be filed with the transportation carrier ALL WARRANTIES INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION OF 24 MONTHS FROM THE ORIGINAL DATE OF PURCHASE LABNET INTERNATIONAL INC S SOLE OBLIGATION UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT AT LABNET INTERNATIONAL INC DISCRETION OF A DEFECTIVE PRODUCT LABNET INTERNATIONAL INC IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGE COMMERCIAL LOSS OR ANY OTHER DAMAGES RESULTING FROM THE USE OF THIS PRODUCT Some states do not allow limitation on the length of impli
8. sed method will not damage the equipment To clean the centrifuge use a damp cloth and a mild noncorrosive detergent ph lt 8 After cleaning ensure all parts are dried thoroughly before attempting to operate the unit Do not immerse the centrifuge in liquid or pour liquids over it Questions and Service should you have a question about the centrifuge or require service for the unit please use the contact numbers listed below Do not send in a unit for service without first calling to obtain a repair authorization number and a decontamination form Should the centrifuge require service be sure to decontaminate it and enclose the decontamination form The unit should be properly packed to avoid damage Any damage resulting from improper packaging shall be the responsibility of the user Specifications Dimensions 5 2 x 5 2 x 4 4 inches 13 2 x 13 2 x 11 2 cm Weight 6 1 2 Ibs 0 55 Kg Electrical AC 230V 50 60Hz 65mA 115V 50 60Hz 130 FUSE 0 5A 250V F 6000 ROI aomen 2000 xg Environmental conditions Indoor use only Altitude up to 2000m Temperature 5 C to 40 C Maximum relative humidity 80 for temperature up to 30 C decreasing linearly to 50 relative humidity at 40 C Pollution degree 2 Spare Parts 10588W005 Lid Handle 10588W015 Rotor Spin Strip 10588W016 Rotor 8 Places COM 014 1