Home

User Manual UWMS-01 Version 2.0

image

Contents

1. ddd dddddd e g W 94 532306 To effectuate the change click Apply li Heartbeat Interval Set the heartbeat interval from 1 to 60 minutes using the drop down box The default interval is 20 minutes To effectuate the change click Apply iii Heartbeat On Off You can turn off the heartbeat However it is advised that you always turn on the heartbeat when the UWMS 01 is in operation To effectuate the change click Apply 2008 2009 SYM All rights reserved Page 15 sym User Manual UWMS 01 Version 2 0 3 UWMS 01 IP Address i IP Address The UWMS 01 s default IP address is 192 168 1 100 If you change the default IP address the following dialogue box will appear to confirm In case where you assigned your laptop s IP address manually as opposed to Obtain an IP automatically you must change your laptop s Local Area Connection accordingly to connect to the UWMS 01 In order to open the UWMS 01 s GUI program you will need to login again and type in the new IP address http 192 168 1 100 8888 device_setup asp Default http New IP Address 8888 device_setup asp New Windows Internet Explorer x Are you sure you want to change the IP Address If you dick OK you will need to login with the new IP Address cms Picture 10 UWMS 01 IP Address Change Dialogue Box The Member is not allowed to change the UWMS 01 s IP address Only the Administrator can change the IP
2. sym User Manual UWMS 01 Version 2 0 D UWMS 01 Set up sym T User Manual gt Model Name UWMS 01 Modem Status On Line a fa 1 Site ID amp Manager IP Provides Innovative Wireless Management Solutions gt Site ID Cascade Code SYMTEST SNMP Manager IP fio ez fas fis 4 Wi f i Network Status Heartbeat Control 2 Network Connection PCT Latitude N 001 100000 gt Longitude E 001 100000 Dry Contact Setup Heartbeat Interval 20 min y Heartbeat On Off ON r oh UWMS 01 IP Address 3 X Fa Firmware Update IP Address 192 163 fi fico Subnet Mask fas 7 ss 7 ss 7 T Administrator Tn raS DHCP Control 4 5 UWMS 01 Information a i EE a k A Bo E Pla I I i I Logout 6 2 T 8 l 9 i 10 i X N Bunar A A Rage X 7 Se Picture 9 UWMS 01 Set up Menu Screenshot 1 Site ID amp Manager IP Type in the Site ID assigned by Sprint SNMP Manager IP is the target IP to which the UWMS 01 s data is directed Use 10 22 25 15 default value as the SNMP Manager IP unless you are told otherwise Click the orange Apply button to effectuate the change 2 Heartbeat Control i Latitude and Longitude Type in the GPS information of the site where the UWMS 01 is installed Without the location information heartbeats will not be generated The latitude format is N S ddd dddddd e g N 39 006957 The longitude format is E W
3. QuickstertGuide uwmsoras UWMS01 UWMSOLET UWMSO1SC UWMSOLAT a g HH UWMSO01NS AN gt gt gt 0 UWMS010DC UWMSOLAC UWMSO01DR UWMS0106 2008 2009 SYM All rights reserved Page 3 sym User Manual UWMS 01 Version 2 0 C UWMS 01 at a Glance Power LED PPP LED a q Mounting Hole Port Number LED e atn nh a a a Ethernet Ports Alarm LED for Dry Contact Dry Contact Port Debug Port Power Switch 12VDC Power Port Antenna Port 2008 2009 SYM All rights reserved Page 4 sym User Manual UWMS 01 Version 2 0 Il Installation Overview Drawing 1 shows a typical installation when the UWMS 01 is set up with its supplied dipole antenna Make sure the received signal strength is greater than 85 dBm at the installation site Remote Unit A y y Donor Antenna a 7 E SS e O Expansion HUB Unit A j a E aac lt A Main HUB Unit he Ethemet Cable EA a 1 M if Server Antenna i UWhMS 0 1 X SS ACIDO Adaptor Drawing 1 Connecting the UWMS 01 to a DAS using a dipole antenna If sufficient signal is not present at the installation site you have a few options 1 You can couple the stronger signal from the Device s donor port using an RF coupler See Drawing 2 d Donor Antenna RF Coaxial Cable Optional RF Coupler Optional RF Splitter Server Antenna Ethernet Cable
4. s modem connection status On Line Off Line On Line ay Off Line ES 4 Network Device Status The Network Device Status displays the information of the Devices connected to the UWMS 01 A total of 32 Devices can be displayed in the table When the UWMS 01 receives heartbeats from the Devices periodically the Device information is in black If more than 24 hours pass without receiving a single heartbeat from a Device the Device is indicated in red indicating inactivity This will turn black again when the UWMS 01 starts receiving heartbeats from the previously dormant Device 2008 2009 SYM All rights reserved Page 9 sym User Manual UWMS 01 Version 2 0 B Network Connection You can add or delete Devices manually sym 2 User Manual gt Model Name UWMS 01 Modem Status On Line a Pl An f 1 Add New Device Provides Innovative Wireless ne ES E NT E AAA bb II 19 2 O Network Device Status A EEN Network Status EC 1 REPEATER1 192 168 1 11 RPT1 RF REPEATER QO 2 REPEATER2 192 168 1 12 RPT2 RF REPEATER x UWMS 01 Setup 3 DAS1 192 168 1 13 DAS1 INDOOR DAS QO Firmware Update 4 DAS2 192 168 1 14 DAS2 INDOOR DAS x Administrator UWMS 01 Information Logout Picture 2 Network Connection Menu Screenshot You can add Devices to the UWMS 01 either automatically or manually When you connect a Device simply wait until the Device starts sending out a heartbeat to the UWMS 01 If t
5. Due to its universality any HTTP based devices with standard Ethernet interface can be connected to the UWMS 01 Using the UWMS 01 Sprint will be able to access the Devices connected to the UWMS 01 to monitor them or change their parameters without visiting the physical site This wireless monitoring and control capability enables Sprint to proactively diagnose and troubleshoot problems remotely even before a customer complaint is received This translates into less network management costs and increased customer satisfaction This means anytime anywhere access to Sprint s Devices from everywhere Higher data throughput using 1xEV DO Rev A wireless module Managing multiple devices up to 8 repeaters or 32 DAS remote nodes simultaneously Built in 10 100 Mbps switching HUB Eight Ethernet ports Conversion of dry contact alarms to SNMP alarms Tested compatibility with the following Devices ADRF Repeaters Andrew ION B Dekolink Repeaters GS Teletech Repeaters LGC Fusion MobileAccess 410 SK Telesys Repeaters and R tron Repeaters The UWMS 01 works seamlessly with multiple Devices from the different manufacturers listed above For the most recent list of compatible Devices please visit www symtechnology com 2008 2009 SYM All rights reserved Page 2 sym User Manual UWMS 01 Version 2 0 B What is in the Box UWMS 01 Main Body UWMSO1 Ethernet Cable UWMSO1ET 8 DEAS maleto male Cable UWMSOIDR 9
6. a Class B digital device pursuant to the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This system generates uses and can radiate RF energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this unit does cause harmful interference to radio or television reception which can be determined by turning the unit off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the unit and receiver Connect the unit to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician E Manufacturer s Limited Warranty SYM Technology Inc SYM offers a limited warranty that the enclosed unit Product will be free from defects in material or workmanship as follows FIVE 5 YEAR LIMITED WARRANTY For a period of five 5 years from the date of original purchase SYM will at its option either repair or replace a defective Product with new or rebuilt parts replacement LIMITED WARRANTY ON REPAIRED REPLACED PRODUCTS After SYM repairs or replaces the Product the repaired or replaced
7. address ii Subnet Mask The default Subnet Mask is 255 255 255 0 4 DHCP Control If you cannot assign a Static IP address to the Device and the Device has a DHCP client the DHCP server of the UWMS 01 will automatically assign an IP address to the Device connected The IP addresses assigned by the UWMS are within the range from 192 168 1 110 to 192 168 1 199 The default DHCP mode is on 5 Apply To effectuate changes you make in 1 through 4 click Apply then the page will refresh 6 Modem Reset You can manually force the modem to re register on the network by clicking Modem Reset When you are connected remotely you need to login again after you reset the modem Windows Internet Explorer l Windows Internet Explorer Remote link will be disconnected dd e to res F dare E Are you sure to reset the modem Please login again Picture 11 Modem Reset Confirmation Dialogue Box The UWMS 01 automatically terminates the PPP session and re registers every hour automatically 2008 2009 SYM All rights reserved Page 16 sym User Manual UWMS 01 Version 2 0 7 Reboot You can restart the UWMS 01 by clicking Reboot If you click OK your current Web browser will be closed and after 2 3 minutes you can login again Windows Internet Explorer i ll Windows Internet Explorer R System will reboot Are you sure to reboot the UWMS5 01 Please login again cana Picture 1
8. this document could void your warranty B Radio Frequency RF Energy The UWMS 01 is a radio transmitter and receiver just like your mobile phone When it is turned on it receives and transmits radio frequency RF signals The RF power level can range from 0 006 watt to 0 25 watt Please avoid working in close proximity within 20 cm to the UWMS 01 For more information about RF exposure visit the FCC Web site at www fcc gov C Specific Absorption Rates SAR The SAR is a value that corresponds to the relative amount of RF energy absorbed in the head of a user of a wireless device SAR values at or below the federal standard of 1 6 W kg are considered safe for use by the public Although the UWMS 01 is to be mounted or placed at a specific location take caution not to have prolonged exposure to the UWMS 01 in close proximity D FCC Notice This system complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this system may not cause harmful interference and 2 this system must accept any interference received including interference that may cause undesirable operation Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment 2008 2009 SYM All rights reserved Page 23 sym User Manual UWMS 01 Version 2 0 Note This system has been tested and found to comply with the limits for
9. 2 Reboot Dialogue Box The UWMS 01 automatically reboots itself every 12 hour to protect itself from an unexpected interruption of operation and memory shortage 8 View Log By clicking View Log you can see some vitals of the UWMS 01 in text format 9 Load Configuration By clicking Load Configuration you can download the configurations that you had previously saved It is especially convenient when you have to replace an UWMS 01 with a new unit You do not need to set up the UWMS 01 again By simply downloading the saved configuration you can restore the configuration that you had previously saved 10 Save Configuration You can save the current UWMS 01 configurations to your laptop for future reference 2008 2009 SYM All rights reserved Page 17 sym User Manual UWMS 01 Version 2 0 E Firmware Update You can update the UWMS 01 s firmware sym 2 User Manual Model Name UWMS 01 Modem Status On Line a Provides Innovative Wireless Management Solutions O Firmware Update Hetwork Status Network Connection F File Name Browse Dry Contact Setup Click Browse to locate new firmware Click Update to update firmware UWMS 01 Setup A i 2 A UDOaate Firmware Update A N a Administrator UWMS 01 Information Logout Picture 13 Firmware Update Menu Screenshot 1 File Name Click Browse and locate the firmware on your laptop Then click the Update button 2 Update When the
10. A Use different Site ID Picture 5 Identical Site ID Exists Dialogue Box Static IP address Device s fixed IP address assigned by installer The Static IP must follow the proper format and the IP address must be within the range specified e g 192 168 1 XX XX can be any number from 2 to 99 See also Il Installation Overview 1 a Change Device s IP address and Site ID on Page 6 When the Static IP is either in the wrong format or out of the range the following dialogue box will appear Windows Internet Explorer l x Input correct Static IF 192 168 1 XX XX can be any number from 2 to 99 Picture 6 Input Correct Static IP Address Dialogue Box 2008 2009 SYM All rights reserved Page 11 sym User Manual UWMS 01 Version 2 0 Model and Type information are optional You will be able to register the Device without inputting the Model and Type information However the Site ID and Static IP address must be provided Model Alpha numeric up to 25 characters showing Device model name Type Alpha numeric up to 20 characters indicating Device type e g RF Repeater DAS Router UPS etc 2 Network Device Status The table displays all the Devices connected to the UWMS 01 A maximum of 32 Devices can be displayed in the table If you want to remove a Device simply click the red button in the Delete column The following dialogue box will appear to confirm Windows Internet Explorer Picture 7 D
11. ANY INCIDENTAL OR CONESQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS LOSS OF SALES OR LOSS OF USE OF THE PRODUCT SYM MAKES NO OTHER EXPRESS WARRANTY EITHER WRITTEN OR 2008 2009 SYM All rights reserved Page 24 sym User Manual UWMS 01 Version 2 0 ORAL WITH RESPECT TO THE PRODUCTS THE DURATION OF IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IS LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY SYM Technology Inc Attention Customer Service Phone 626 394 6630 Email support symtehcnology com Vil Glossary DAS istribated Antenna system OOOO O EN SS dRlectronic SerialNumber ops tal Positioning system O O O OOOO CA nt to Point Protocol O O O OOS O O 2008 2009 SYM All rights reserved Page 25
12. Consumption 12 W Max Ethernet m Standard Compatibility IEEE802 3 CSMA CD m Ethernet Link MDI MDI X auto crossover m Data Rate 10 100MBps Auto Negotiation half full duplex m Address Database Size 1024 MAC addresses m Switching Capacity 1Gbps B Environmental Specifications m Operating Temperature 14 158 F m Operating Humidity O 90 C Mechanical Specifications m Dimension inches W 10 55 D 6 22 H 1 77 m Weight Ibs 3 2 2008 2009 SYM All rights reserved Page 22 sym User Manual UWMS 01 Version 2 0 VI Safety and Warranty Information A General Precaution There are several simple guidelines to operating the UWMS 01 properly and safely Avoid exposing the UWMS 01 to extreme temperatures either hot or cold The UWMS 01 is for indoor use only Keep the unit in a clean well ventilated and dust free place Avoid exposing the UWMS 01 to rain or liquid spills If the UWMS 01 gets wet immediately turn off the power and dry the unit completely Use only the power supply adapter that comes with the unit Replacement power supply adapters may be ordered from SYM Technology Treat the UWMS 01 with care Avoid dropping throwing or sitting on it Rough treatment may damage the unit and void the warranty Do not attempt to disassemble your unit If the warranty seal has been broken the warranty is no longer valid Any changes or modifications to your unit not expressly approved in
13. Product shall be covered by warranty for the remaining time of the original warranty period or for ninety 90 days from the date of repair whichever is longer Repair or replacement may include the use of functionally equivalent reconditioned units Replaced faulty parts or components will become the property of SYM Technology This limited warranty does not cover and is void with respect to the following i Products which have been improperly installed maintained modified or repaired ii Products which have been subject to outdoor use misuse physical damage abnormal use or operation improper handling or storage exposure to fire water excessive moisture or extreme temperature iii Products operated outside published maximum ratings iv Products on which warranty seals or Product serial numbers have been removed broken or altered v cost of installation set up removal or reinstallation vi signal reception problems or network problems unless caused by defect in material or workmanship vii damage as a result of fire flood power surge lightening acts of God or other acts which are not the fault of SYM and which the Product is not specified to tolerate viii any Products which have been opened modified or repaired by anyone other than SYM or a SYM authorized service center REPAIR OR REPLACEMENT AS HEREINABOVE PROVIDED IS YOUR SOLE AND EXCLUSIVE REMEDY FOR BREACH OF THE LIMITED WARRANTY SYM SHALL HAVE NO LIABLITY FOR
14. RF Repeater Drawing 2 Connecting the UWMS 01 to a repeater of which donor signal is coupled to the UWMS 01 s antenna port 2008 2009 SYM All rights reserved Page 5 sym User Manual UWMS 01 Version 2 0 2 You can place the UWMS 01 where there is a Sprint signal greater than 85 dBm But make sure the distance between the UWMS 01 and the Device does not exceed approximately 328 feet 100 meters or 3 You can place the UWMS 01 near the Device but place the supplied dipole antenna where there is a Sprint signal greater than 85 dBm using an extension coaxial cable 1 In order to set up the UWMS 01 you have to change the Device s network configuration first Device is the Sprint approved network equipment e g repeaters and DAS that you want to monitor using the UWMS 01 We assume that all Devices have HTTP based local GUI Please contact the Device manufacturer if you do not know how to access the local GUI of the Device and how to change its settings a Change the Device s IP address and Site ID Cascade code to the following IP address 192 168 1 XX XX can be any number from 2 to 99 Subnet mask 255 255 255 0 Default gateway 192 168 1 100 Manager IP 10 22 25 15 Site ID Cascade code Unique Site ID assigned by Sprint When you connect multiple Devices to the UWMS 01 assign different IP addresses to the Devices e g 192 168 1 2 192 168 1 3 and 192 168 1 99 Also each Site ID Cascade
15. cally when in normal operation PPP LED is lit in solid green when PPP session is on Data LED blinks in green only when data is being transmitted Corresponding CH LED s to which Devices are connected are lit in green f Congratulations The Devices can be monitored and controlled through Sprint networks wirelessly and remotely 2008 2009 SYM All rights reserved Page 8 User Manual UWMS 01 Version 2 0 sym lll Setting up the UWMS 01 Using Graphic User Interface The UWMS 01 s GUI consists of eight 8 intuitive easy to follow menus When you logged in as a Member you will see seven 7 menus Only the Administrator can see the Administrator menu A Network Status i ie a 2 1 Y User Manual Model Name UWMS 01 gt Modem Status On Line a 3 S pm A y e s PS 4 Network Device Status Pi Provides Innovative Wireless Mea Management Solutions 1 REPEATER1 192 168 1 11 RPT1 RF REPEATER 1 Network Status 2 REPEATER2 192 168 1 12 RPT2 RF REPEATER S ye Eli DAS1 192 168 1 13 DAS1 INDOOR DAS Network Connection 4 DAS2 192 168 1 14 DAS2 INDOOR DAS Dry Contact Setup UWMS 01 Setup Firmware Update Administrator UWMS 01 Information Logout Picture 1 Network Status Menu Screenshot 1 Network Status gives you at a glance overview of the Devices connected to the UWMS 01 2 You can open save print the UWMS 01 s User Manual 3 The Modem Status displays the UWMS 01
16. code must be unique for each Device Alternative Set up IP address Subnet mask Default gateway If the Device does not allow you to change its static IP address and has the DHCP client feature the UWMS 01 will assign the IP address automatically Manager IP 10 22 25 15 Site ID Cascade code Unique Site ID assigned by Sprint b Make sure the Device s heartbeat mode is on and set heartbeat period to 20 minutes For testing purposes you may want to set a shorter heartbeat period e g 1 minute Make sure to change it back to 20 minutes before you leave the installation site c Make sure the Device has GPS latitude longitude of the site information stored If GPS information is missing Sprint NOC will not accept heartbeats from the site d Make sure the Device is working properly 2 Connect the UWMS 01 to the Device as shown above in Drawing 1 or Drawing 2 a Using the supplied Ethernet cable connect Device to the UWMS 01 s Ethernet port 2008 2009 SYM All rights reserved Page 6 sym User Manual UWMS 01 Version 2 0 b The UWMS 01 can be powered by the supplied AC adapter UWMSO1AC or by DC power cord UWMSO1DC if Device has a 12VDC outlet Using AC power is recommended c Using the supplied Ethernet cable connect your laptop to the UWMS 01 s Ethernet port d Turn on the UWMS 01 3 Change your laptop s Local Area Connection setting a Go to Network Connections gt Local Area Co
17. eletion Confirmation Dialogue Box 2008 2009 SYM All rights reserved Page 12 7 User Manual UWMS 01 Version 2 0 sym C Dry Contact Set up Some legacy Sprint Devices do not have Ethernet interface e g MA 410 Devices which have dry contact alarms can still be connected to the UWMS 01 through the UWMS 01 s dry contact port The UWMS 01 can receive up to four 4 dry contact alarms and convert these to one of the five 5 SNMP alarms defined in the Sprint MIB There are four 4 LEDs on the bottom of the UWMS 01 matching the four 4 dry contact alarms When an alarm event occurs the corresponding dry contact LED will be lit in solid green When the alarm clears the LED will be off sym T User Manual Model Name UWMS 01 gt Modem Status On Line a a Je Add New Dry Contact Alarm Provides Innovative Wireless A AA 3 i RF POWER z 0 2 0 Dry Contact Alarm Status SSS 2S ee a Dry Contact Setup MA410TEST RF POWER MA 410 Indoor DAS Network Status 2 MA410TEST UNDER CURRENT MA 410 Indoor DAS E UWMS 01 Setup r Firmware Update 4 Administrator Dry Contact Connector Pinout Un 01 iedomaton ES ee SS ae Port 3 Normal Open Port 4 Common Port 1 Common ES rae ES 5 4 4 i 3 2 Port 3 Normal Close 7 Port 2 Normal Open 12 Port 2 Common L A Vinsa i sal N gaad e h Basco 3 Port 3 Common 8 Port 1 Normal Close 13 Port 2 Normal Close 15 11 4 Port 4 Normal Open 9 Not Connected 14 Not Connected DE 15 Fema
18. firmware is downloaded and updated successfully the following dialogue box will appear When you click OK the UWMS 01 will restart TT cons Picture 14 Update Successful Dialogue Box 2008 2009 SYM All rights reserved Page 18 sym User Manual UWMS 01 Version 2 0 F Administrator You can manage user accounts that can access the UWMS 01 by assigning different levels of access rights sym T User Manual Model Name UWMS 01 Modem Status On Line a nt Management New account Administrator Provides Innovative Wireless PR po ens f 1 1 Management Solutions i 2 i 3 y J e J E J Account Management Network Status po OE ee ee 1 Network Connection admin admin administrator Dry Contact Setup 2 sym sym member x UWMS 01 Setup Firmware Update rta UWMS 01 Information Logout Picture 15 Administrator Menu Screenshot The Administrator Menu is only available when you are logged in as the Administrator Super User When a Member logs in the Member cannot access the Administrator Menu 1 Account Management Displays the User Name and Password of all the registered accounts To delete an account click the red button under the Edit column 2 New Account To create a new account click New Account type in new User Name and Password then click Apply User Name and Password can be up to 15 alpha numeric characters They are case sensitive Do not use any spaces or
19. he Device s Site ID and Static IP are set up correctly and the Device is sending out a heartbeat the UWMS 01 will receive the Device s heartbeat information and register the Device automatically Alternatively you can manually input the Device s information Site ID Static IP Model and Type in the Add New Device table 1 Add New Device Type in the necessary information Site ID and Static IP address and then click the plus sign You will see the information added in the Network Device Status table If the Site ID or Static IP information is missing the following dialogue box will appear Windows Internet Explorer A Site ID is required Windows Internet Explorer xj A IP Address is required Picture 3 Information Missing Dialogue Box 2008 2009 SYM All rights reserved Page 10 sym User Manual UWMS 01 Version 2 0 You can add up to 32 different Devices to the UWMS 01 If you attempt to add more than 32 Devices the following dialogue box will appear Windows Internet Explorer x A No more Device can be added Picture 4 Devices Maxed Out Dialogue Box Site ID Device s unique Cascade code provided by Sprint The Site ID can be up to 35 alpha numeric characters upper and lower cases Do not use spaces or special characters All Site IDs must be unique When you input a Site ID that is already registered the following dialogue box will appear Windows Internet Explorer Ed
20. le i 5 Port 4 Normal Close 10 Not Connected 15 Port 1 Normal Open Picture 8 Dry Contact Set up Screenshot 1 Add New Dry Contact Alarm Assign a proper Port number 1 4 input Site ID provided by Sprint select one of the 5 alarms with which you want to associate the dry contact alarm then click the blue plus sign If you select RF Power when alarm event occurs Sprint NOC will see the event as RF Power alarm Model and Type information are not required 2 Dry Contact Alarm Status The table shows the information of the registered dry contact alarm You can delete the Device by clicking the red button in the Delete column 2008 2009 SYM All rights reserved Page 13 sym User Manual UWMS 01 Version 2 0 3 Connector The UWMS 01 has a 3 row DE 15 female connector same as the VGA RGB connector 5 1 15 11 4 Connector Pin Map Please refer to the pin map information in the table when you connect a Device with dry contact alarm The supplied DE 15 male to male cable only works with the MA 410 You may need a customized cable to have your Device work with the U WMS 01 Please contact our technical support if you need further assistance Pin Function Pin Function Pin Function Port 3 Normal Open LE Port 4 Common Port 1 Common Port 3 Normal Close Port 2 Normal Open Port 2 Common Port 3 Common na Port 1 Normal Close Port 2 Normal Close AA area 2008 2009 SYM All rights reserved Page 14
21. n battery some laptops automatically disable the LAN card Enable the LAN card when operating on battery You should turn off Wi Fi since this may cause the LAN to disable You can also try the following 1 disconnect the LAN cable and connect it again 2 disable Local Area Connection and then enable it again or 3 reboot the UWMS 01 Can t access Device s GUI Make sure the distance between the UWMS 01 and the Device is less than 328 feet 100 meters If the problem persists contact the Device manufacturer Device is not registered Check the device s heartbeat setting Heartbeat must be turned on automatically in Network Turn off the UWMS 01 and turn it back on Turn off the Device and turn Device Status table it back on Check the Device s IP settings Heartbeat is not generated Make sure the Device has latitude and longitude information stored correctly Make sure Device s heartbeat is turned on Make sure PPP LED is lit in solid green Can t change the Device s If the Device won t allow you to change its IP address and has the DHCP Static IP address client feature make sure the UWMS 01 s DHCP is on Contact the Device manufacturer 2008 2009 SYM All rights reserved Page 21 sym User Manual UWMS 01 Version 2 0 V Technical Specifications A Electrical Specifications Power Supply m AC Power Supply Input AC 100 240V 50 60Hz m DC Power Supply Direct DC Supply Input 12V 1V 2A m Power
22. nnection gt Internet Protocol TCP IP Properties Select Obtain an IP address automatically It may take a few minutes to obtain an IP address b Alternatively you can select Use the following IP address and input the following information IP address 192 168 1 200 Subnet mask 255 255 255 0 Default gateway 192 168 1 100 4 Configure the UWMS 01 a Open Microsoft Internet Explorer and type the following URL http 192 168 1 100 8888 b When prompted input the following User Name and Password User Name sym Password sym c Go to UWMS 01 Set up menu and input the following information then click Apply Site ID Cascade code Change SYMTEST to the Site ID provided by Sprint Latitude Input the latitude information N S ddd dddddd Longitude Input the longitude information E W ddd dddddd Heartbeat Interval 20 minutes Heartbeat On Off On For more detailed instructions refer to Chapter III D UWMS 01 Set up on page 15 d Go to Network Device Status menu and check whether the Devices are automatically registered in the Network Device Status table For more detailed instructions refer to Chapter III A Network Status on page 9 e Visual inspection Confirm from the UWMS 01 s front panel that the LEDs show normal operation as follows 2008 2009 SYM All rights reserved Page 7 sym User Manual UWMS 01 Version 2 0 Power LED is lit in solid green Status LED blinks periodi
23. special characters 3 Administrator You can change the Administrator s account information only when you are logged in as the Administrator The default User ID and Password are admin for both 2008 2009 SYM All rights reserved Page 19 User Manual UWMS 01 Version 2 0 G UWMS 01 Information sym sym 2 User Manual Model Name UWMS 01 gt Modem Status On Line a Provides Innovative Wireless Management Solutions Fas UWMS 01 Information 1 EVDO Module Information 2 F Network Status Model Novatel E725 Model UWMS 01 Network Connection A MON E Version 1 0 8 ESN 09106017495 S N UMO1010001 Dry Contact Set 2 eit i ae Channel si 50 Tech Support 626 394 6630 UWMS 01 Setup CDMARSSI 85dBm E mail support symtechnology con EVDORSSI 87dBm Firmware Update Administrator UWMS 01 Information Logout Picture 16 UWIMS 01 Information Menu Screenshot 1 UWMS 01 Information Displays the UWMS 01 s system information including its firmware version and serial number Please have the information handy when you contact SYM s technical support 2 EVDO Module Information Model Displays the manufacturer and the model of the module which resides in the UWMS 01 MDN Displays the Modem Directory Number ESN Displays the modem s Electronic Serial Number Channel Displays the channel number which was assigned by the nearest BTS RSSI Displays the received signal strength for
24. sym User Manual UWMS 01 Version 2 0 Table of Contents I Introduction A SA o II 2 B What SIM the BOX sas cccasieicnsssedntesonsscniannecssbaewanswnateceantassabaaadenienes sapeansateneacuecassanscncses 3 E UWWS 0L ata GINCO eera 4 Il Installation OVervieW icouiioiiniana ni doo acia 5 lll Setting up the UWMS 1 Using Graphic User Interface As Network Sea NS senn E EES 9 B Network Connector E E E 10 Ae A E TAE o e 13 D UWIIS 0L SOU U erpen ene AEE EAEE AN EARNE Ee 15 E Firmware Update A o e O OO o N 18 Fe AON GO A A E 19 6G E o ess 20 e LOP OU ciao 20 IV Troubleshooting scanner 21 V Technical Specifications A Electrical SpeciticaON Strait 22 B Environmental SpecificatiONS oocconoccnononanononnnnonnonnnnnnnononnononnnonono non nonnoncnrono nan nnnnnn conocia neos 22 Mechanical SpeciicacOnS ninas 22 VI Safety and Warranty Information A General Preca lO asadas iniciaran 23 B Radio Frequency RE ENT csi rito 23 C Specific Absorption Rates SAR usina aa 23 cr PP e E O E E AEE EA 23 E Manufacturer s Limited Warranty ccoooccncnncncnnonooncnoonanannonnnnconononnnananannono non nonnrnnnnonnnnnononanos 24 VICIOSA a 25 User Manual UWMS 01 Version 2 0 sym I Introduction A What is the UWMS 01 The Universal Wireless Monitoring System UWMS 01 enables Sprint to monitor and control its network devices Devices such as repeaters and DAS remotely and wirelessly
25. voice CDMA and data EVDO separately H Logout When you logout you will see a confirmation pop up window When you hit OK you will be directed to the login page automatically 2008 2009 SYM All rights reserved Page 20 sym User Manual UWMS 01 Version 2 0 IV Troubleshooting Power LED is not lit Make sure the power cord is properly connected to the UWMS 01 Make sure the power adapter is properly connected to a functioning power outlet If the power is supplied by other Devices using the DC power cord make sure the Device is properly powered PPP LED is not lit Make sure the modem s received signal strength is greater than 85 dBm If the signal is not sufficient place the UWMS 01 in a place where it has better signal strength e g by a window If you are using the supplied dipole antenna couple the antenna port with an external donor antenna of the system to which the UWMS 01 is connected Status LED is not blinking Make sure the Power LED is lit Turn off the UWMS 01 and turn it back on Can t access UWMS 01 s GUI Make sure the Ethernet cable is connected securely both to the UWMS 01 and your laptop The small green status light next to the Ethernet port should be lit Make sure you changed your laptop s TCP IP settings to Obtain an IP Address Automatically When you type in the URL do not forget the port number at the end e g http 192 168 1 100 8888 When your laptop is operated o

Download Pdf Manuals