CFM-10 Installation Guide - Solid State Organ Systems

image

Contents

1. e The return for the piston lamps should connect to T R positive Blind Pistons and Lamps Blind Pistons are those which are reversible i e they turn on when the piston is first pressed and they turn off when it is pressed a second time They will normally have an indicator lamp to show whether they are on or off MultiSystem makes no differentiation between Inclusive Tutti or Sforzando pistons Exclusive Tutti pistons and Ventil pistons These are all referred to as Blind Pistons Their function will be set during commissioning The MultiSystem console plane documentation will list the pistons as blind piston 1 blind piston 2 etc e Wire each blind piston to one of the blind piston inputs as listed in the MultiSystem console plane documentation e The feed to the piston contacts should connect to T R positive e One side of each lamp should be connected to the Piston Lamp output on the MultiSystem console plane which corresponds to the piston e The return for the piston lamps should connect to T R positive CFM 10 Installation Guide Revision 8 May 2013 Page 8 Blind Switches Blind Switches are those which have an on and an off position MultiSystem makes no differentiation between Inclusive Tutti switches Exclusive Tutti switches and Ventil switches These are all referred to as Blind switches Their function will be set during commissioning The MultiSystem console plane documentation will list the switches as blind s
2. intended to be read in conjunction with the MultiSystem Installation Guide which was delivered with the MultiSystem If you are upgrading a system and the information has been lost please contact us and we will gladly supply a fresh copy from our archives Connections to the MultiSystem Network It is necessary to connect the CFM 10 system to the MultiSystem Network There are two ways to do this 1 Normally the CFM 10 system can be fitted less than 0 5 metres 18 inches from another MultiSystem processor In this case the two coloured ribbon cables can be connected directly using an NP linker 2 When greater distances are required the cable entry to the system must be taken through a link protection board at each end This is identical to a MultiSystem installation Unless this has been specified at the time of ordering you will require two more Link Protection boards which are available ex stock from your local SSOS office part number 62310260 CFM 10 Installation Guide Revision 8 May 2013 Page 5 Direct Connection The system will be supplied with a multicoloured ribbon cable for each black box The cable plugs into the 25 way D type connector in the box at one end and has 3 small 10 way connectors at the other end of the cable These connectors are labelled NEXT PREVIOUS and SPARE For more details on how these connectors relate to the MultiSystem please refer to the MultiSystem Installation Guide The CFM 10 system is sup
3. Exact values are not necessary but larger values are safer than lower ones Suitable resistors for a variety of T R voltages are shown below 1K0 10009 5 0 25W min 1K3 13009 5 0 25W min 1K6 1600Q 5 0 25W min 2K2 22009 5 0 25W min All of the above assume LED s rated at a current of 10mA These values are safe for use with any LED Some LED s are recommended to have a higher current of 20mA In this case the value of the resistor will need to be reduced The resistance should be halved and the power should be doubled Some LED s are available with built in resistors These will usually be labelled as 12V or 24V and do not require a resistor when used at their rated voltage CFM 10 Installation Guide Revision 8 May 2013 Page 11 Commissioning Having wired all of the above the system can now be commissioned The first stage is to check the connection of the on and off coils e Connect a positive lead to the pin marked test input in the connector list for the console plane e Press General Cancel e In test mode each stop s on and then off coil are fired in sequence e If correctly wired each stop will move on and then off In this way wiring errors can be easily identified and corrected before proceeding A stop not moving on may also not move off Try putting stops on and checking to see if they go off during test It is not necessary to stop the test to do this A stop not going on but going off has a
4. OLID TATE CFM 10 Installation Guide North American Office 5600 General Washington Drive Suite B211 Alexandria VA 22312 USA Toll Free 800 272 4775 T 703 933 0024 F 703 933 0025 www ssosystems com European Office Twickenham Avenue Brandon Suffolk IP27 OPD United Kingdom T 44 0 1842 814814 F 44 0 1842 813802 Contents TRO MU CHOM PAE EE passes ssccucsastbssssvedecassusbessosseseenspaashavessetecucbastbeneaactesasyas iesveseseanstacieciss 3 A TWO Miartech aaa cena cca lates tases E R eeseaoas tae fuses useob testes 4 Assembly differences 4 Full Installation Guid tecacscsccicrieatawessieschesiueietesnavasbanssestessescstunbsodetesescs R E 5 Connections to the MultiSystem Network cccccscesssssseescsseeeceeeeeneeseseseseseenensnesessseececeeeeenenenens 5 Direct Connection 6 POWER WAPI Ss ienie nssra o in eaa EE E E A SE AEE EOE EE E adie ean 7 Drawstops and TabstOps scssscssssnescesrseaessnteessvoeassecensnesanesehonseseansenenesd sousesebevesevebesseoestonsesesd sseeveades 7 LUMINOUS SHOPS sscerscsrensssesseresesternenenesceenecnenssssencsescecseenenensesesnenenessneneneneneeensensscssseseseenensnensecesnee 7 Set Piston anid General CaniCel scvesercseotsronssossvessesovonsstesd
5. are provided by a rotary generator as the interference level is far too high Drawstops and Tabstops Drawstops and tabstops require three connections to the MultiSystem as well as one power connection per stop e The switch contact of the stop unit connects to the stop or coupler input on the console plane e The on coil of the stop unit connects to the on coil output on the console plane e The off coil of the stop unit connects to the off coil output on the console plane e The switch feed and the on and off coil returns all connect to T R positive The switch inputs are suitable for use with mechanical switches reed switches or electronic switches The on and off coil outputs are equipped with back EMF or spark suppression Luminous Stops Luminous stops require two connections to the MultiSystem as well as one power connection per stop e The switch contact connects to the stop or coupler input on the console plane e The stop lamp connects to the stop lamp output on the console plane e The switch feed and the lamp return both connect to T R positive The switch inputs are suitable for use with mechanical switches reed switches or electronic switches Set Piston and General Cancel e The set piston should be wired to the set input on the MultiSystem console plane e The general cancel piston should be wired to the general cancel input on the MultiSystem console plane e The feed to both set and general cancel should con
6. ate installation manuals for each system This manual is for CFM 10 only Copyright 1602 Group Ltd 1995 All rights reserved SSOS Stock Number 82S6PC10 CFM 10 capture for multisystem and scope are trademarks of 1602 Group Ltd A Two Minute Guide Even if you are not familiar with our MultiSystems and MultiLevel Capture Systems it is possible to adapt very easily to the CFM system The two minute guide should get you up and running with the minimum of fuss CFM is a supplementary product to the MultiSystem In addition to the MultiSystem the CFM 10 adds e An extra processor box containing the CFM processor unit A small a c power supply that must be connected to a source that remains on after the main power is turned off e Outputs on the console plane to drive the drawstops on and off coils Inputs on the console plane for the level change switch and Piston Inputs Set General Cancel etc Assembly differences The CFM 10 processor box must be added to the MultiSystem Network It can be added anywhere in the network that is suitable using link protection boards and a coloured ribbon cable Normally next to the console processor An NP linker see below for details may be used to simplify this connection The console will require a cut out for the level change switch and capture functions as ordered CFM 10 Installation Guide Revision 8 May 2013 Page 4 Full Installation Guide The following instructions are
7. eieveseveedongisessentusncdevesncaseodevengsensuedgeedese osm 7 SCOPE EM ET o A ss 0ssutcsensatvdseusssesesesededeocesasestenseseaens tedetsensisusituseonscinsesonene E 8 Ordinary Pistons amp Piston Lamp cccceseseeseseeseseseenenssescsceseceeeeeseneseseseseseasnanesescsesceceeeeensnenees 8 Blind PIstOMs BiG Lamp Sensini E E dees ratiae E ER 8 Binid Swi tahes oessa E EE E 9 10 Way Level Selector i100 tsssisaesarscaadecierarste asta avarsccsasvissasievatanstarssinetsnnseaas sdadersbatnreta aianeansieeiees 9 Blind Check Clear and Copy Switches ccccscccsesesessssssssesssessecseesenenessesesessensnsnsscassceseceeeeeeseenees 9 Lock switch and Indicator Lamp cccceseesesesetesesesssnssesesesssceseceeeuesenesesesesesnsnsnessscsseeesseeeesieness 10 Using LEDS oc oenssenats devsessuevesess tensa stv ssenbs eseina AE EEEE ESEE EAEE TEENER EE REEERE EAS 11 COMMISSIONING 5 cc ces a E EE E E E E 12 Introduction This MultiSystem is fitted with an integrated Capture System we call it Capture For MultiSystem or CFM for short In the package you will find an operating guide for the organist Please leave this in the console when you have completed the installation We are always happy to supply extra copies should you require them This document is concerned only with the installation of the system CFM systems are available in three models CFM10 CFM25 and CFM300 Each system is quite different and to avoid confusion we have provided separ
8. faultly off coil A stop not moving at all may have the on and off coils swapped A stop not going off but does go on may have a faulty stop switch not giving a positive to the CFM 10 stop input Try testing each as follows Stop switch With a test lamp connected to negative and all stops on test mode not selected Check each stop switch has a positve voltage the lamp will light Off coils After checking stop switches Connect test lamp to positive Switch first stop on connect test lamp to first stop push General Cancel lamp should flash briefly repeat for next stop until complete Referring to the User Manual carry out the following steps e Select Level one e Set the Scope of every ordinary piston e Set the Scope of all blind pistons e Set all the blind pistons Within the system momentarily connect a positive lead to the default level input This will cause the current scopes and blind functions which have just been set on level one to be stored for later use Referring to the User Manual now carry out the following steps e Select Level two Set any piston with any selection of stops on level two It is not possible to clear a level if it is empty e Clear Level two e Clear Level two a second time e Repeat the above operations for the remaining levels 3 8 This will set the default scopes and blind functions on each of the levels It will leave all of the pistons blank ready for use It is also possib
9. le to set different Sopes in different levels Full instructions for this and other functions may be found in the user manual CFM 10 Installation Guide Revision 8 May 2013 Page 12
10. nect to T R positive CFM 10 Installation Guide Revision 8 May 2013 Page 7 SCOPE Piston Scope is a new feature which allows the organ builder and organist to define which stops are affected by which pistons Scope should be mounted as a piston adjacent to the set piston as it needs to be operated by the same hand that presses the set piston If it is not desirable to mount Scope on the console it should be wired to a toggle switch behind the music stand or in the back of the console Important Note Scope is required for commissioning e One side of the Scope piston should be wired to the Scope input on the MultiSystem console plane e The other side of the Scope piston should be wired to T R positive Ordinary Pistons amp Piston Lamps MultiSystem makes no differentiation between General pistons Divisional pistons and reversers These are all referred to as Ordinary Pistons Their function will be set during commissioning The MultiSystem console plane documentation will list the ordinary pistons as piston 1 piston 2 etc e We recommend that General pistons are wired to the first piston inputs followed by divisional pistons and finally reversers e The feed to the piston contacts should connect to T R positive e If luminous pistons are fitted their lamps should be connected as follows e One side of each lamp should be connected to the Piston Lamp output on the MultiSystem console plane which corresponds tohte piston
11. plied with a small circuit board with 2 connectors known as an NP Linker If you wish to connect the CFM 10 system directly plug the NEXT connection of one ribbon cable and the PREVIOUS connection of the other ribbon cable into the board Which NEXT and PREVIOUS you chose will be determined by the existing wiring on the MultiSystem It does not matter to the CFM 10 system either will operate perfectly e e e e e e A IB A Console Organ CFM 10 Processor a 4 Ne Q se ae i a 7 g Se Nery 5 Previous NP Linker Data Cable CFM 10 Installation Guide Revision 8 May 2013 Page 6 Power Wiring The CFM system requires power from a local DC rectifier T R The box is fitted with a pair of terminals to connect to the supply This supply must be reasonably stable and free from electrical noise most commercially available units are suitable Unlike other SSOS products which are limited to a maximum of 24 volts the MultiSystem products will operate over a range between 12 and 32 volts The CFM 10 system also requires an additional a c power source that is normally on As a minimum this supply must remain on for five minutes after the main supply is switched off so it is OK to remove the power for maintenance The system will not operate satisfactorily from DC supplies which
12. sed for the switch wiring Lock switch and Indicator Lamp The lock switch is a momentary action key operated switch used for locking and unlocking levels The lock indicator lights whenever the currently selected level is locked The lock switch is usually supplied by SSOS e Connect Pin 3 to positive e Pin 4 connects to the lock switch input on the MultiSystem console plane The lock indicator lamp should be mounted next to the lock switch It should be wired as follows e One side of the lock indicator lamp connects to positive e The other side of the lamp connects to the lock lamp output on the MultiSystem console plane Lock switch showing connections use only pins 3 and 4 CFM 10 Installation Guide Revision 8 May 2013 Page 10 Using LED s LED s are solid state devices which emit light They may be used in place of lamps if certain conditions are met LED s only work one way round The cathode connects to the negative end of the circuit and is indicated by the shortest lead or by a flat on the body of the LED LED s work at voltages between 2V and 3V To prevent damage they require a resistor in series with them in order to limit the current flowing through them The resistor has two values its resistance measured in ohms and its power measured in watts To calculate these two values use the following formulae resistance T R voltage 2 100 ohms Q power T R voltage 2 100 watts W
13. witch 1 blind switch 2 etc e Wire each blind switch to one of the blind switch inputs as listed in the MultiSystem console plane documentation e The feed to the switch contacts should connect to T R positive 10 Way Level Selector Memory level selection on CFM 10 is by means of an ten way switch e The switch common should be wired to T R positive e The ten contacts should be wired to the ten level select inputs on the MultiSystem console plane d o Connect pins 1 8 to memory level inputs as shown in connector list _ Connect tag marked A to Positive E Blind Check Clear and Copy Switches CFM 10 is supplied with 3 switches one each for Blind Check Clear and Copy Each of these switches has a built in lamp The Blind Check switch is only required on systems fitted with blind functions such as tuttis ventils and sforzandos e One side of each switch should be connected to either the Blind Check input the Clear input or the Copy input on the MultiSystem console plane e One side of each lamp should be connected to either the Blind Check Lamp output the Clear Lamp output or the Copy Lamp output on the MultiSystem console plane e The other side of the switch and the lamp should be connected to T R positive CFM 10 Installation Guide Revision 8 May 2013 Page 9 A rear view of the switch lamp The lamp connects to contacts a and b Contacts marked 3 and 4 are normally open and should be u