Home
Trotec T510 Operating Manual
Contents
1. EN Operating manual Material moisture measuring device T510 DITROTEC Building moisture measurement The electric conductivity of a dry mineral construction material e g cementitious screed is very low When the building material absorbs water the conductivity of the material can quickly increase or the resistance decrease What needs to be considered for the assessment of the measure ment results is that the results are affected by the material com position of the measured goods e The presence of soluble salts can distort the measurement result substantially The more salt is present the higher will be the displayed measurement value e Yet another variable for the evaluation of the results is the connection of the electrodes with the construction material In case of mineral porous building materials slight electrode contact can cause a comparatively high contact resistance This can falsify the result of the measurement The accuracy of the measurement results is thus lower for min eral construction materials than for wood Building moisture measurements allow only qualitative conclu sions about the moisture dry damp wet Quantitative conclusions about the moisture content of the min eral material to be measured can only be drawn by applying the Darr procedure or the CM method Notes regarding the building moisture measurement e Make sure you have set the correct type of measurement build e For
2. Always measure the material moisture at three different positions in order to achieve a sufficient accuracy by means of the arithmetic average Do not measure the face because there are mainly dry ar eas Preferably do not measure at cracks branches or resin pockets either Oily and or aqueous timber preservatives affect the measure ment result If possible do not measure wood with a temperature below 5 C Too low wood temperatures distort the result of the measurement Avoid static charge of the material to be measured due to friction Static charge distorts the measurement result With a wood moisture of less than 10 electrostatic forces can appear at the good to be measured This can falsify the result of the measurement Experience has shown that this occurs at the outlet of veneer drying plants Remove the stat ic charge by use of suitable grounding measures The temperature value set within the device must be identical to the wood temperature Example With a set temperature value of 20 C and a wood tempera ture of 30 C the measurement result would be distorted up wards by approx 1 5 The measurement s accuracy depends on the contact pres sure of the measuring tips The measuring tips must be con nected to the wood in a way that the contact resistance is small as compared to the measuring resistance The measurement results ought to be checked on a sample basis by means of the Darr test
3. fully are void of any warranty and warranty claims Cleaning the device 1 Use a soft lint free cloth for cleaning 2 Dampen the cloth with clean water Do not use sprays sol vents alcohol based or abrasive cleaners to dampen the cloth 3 Clear dirt from the housing the connections and the colour display Battery change Change the batteries when the message Batt lo is displayed upon switch on or the device can no longer be switched on See Insert ing the batteries on page 5 Exchanging measuring tips Exchange the measuring tips when these exhibit signs of wear e g oxidation heavy contamination See Installing the measur ing tips on page 4 Note The device s measuring tips are bordered by use of special cap nuts and screwed in place A slight clearance within the nuts is intended To avoid peak load it is possible that the tips loosen somewhat after a few measurements Hence regularly check the cap nuts for tight fit and if required retighten them by hand In order to avoid damage to the threads please do not use any tools such as pliers when doing so Operating manual Material moisture measuring device T510 DITROTEC Disposal In the European Union electronic equipment must not be treated as domestic waste but must be disposed of professionally in accordance with Directive 2002 96 EC of the European Parliament and Council of 2 th January 2003 concerning old electrical and electronic
4. 80 the moisture content skyrock ets Operating manual Material moisture measuring device T510 gt TROTEC Sorption isotherm of plaster 1 5 water content uy in io 0 5 0 0 02 04 06 08 1 0 relative humidity 4 This was also confirmed by the calibration measurements of the Institute of Building Materials Research IBAC Therefore one can conclude that a direct correlation between measured value and mass related moisture content is not possible As sufficient criterion for the classification of the measured values it can however be stated that plaster can be considered dry when the measured resistance value is smaller than 30 digits When evaluating the measured values it is imperative to observe that different marginal conditions prevail for every measurement Important variables influencing the worth of the measured value are the connection of the electrodes to the material to be meas ured the material temperature the construction material s com position salt loading and aggregates For construction materials not listed usually sufficient conclu sions can be drawn owing to local reference values As a conse quence the affected damp area can be narrowed down to such an extent that a comparative measurement is carried out at an evidently dry wall or floor area as basis of valuation By use of the higher measured values of the area to be assessed the spreading of the damp area can well be
5. Danger amp When handling the device there is a risk of injury due to the exposed measuring tips Always put on the protective cap when not in use Danger Do not leave the packaging lying around Children may use it as a dangerous toy ZN Danger The device is not a toy and does not belong in the hands of children Danger Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way Observe the personnel gualifications Caution Exclusively use the original measuring tips included in the scope of delivery Other measuring tips might bend or damage the holder at the measuring device P Caution Never force the measuring device into the material to be measured or yank it out Applying force can lead to bending or breaking of the measuring tips gt Caution To prevent damages to the device do not expose it to extreme temperatures extreme humidity or moisture Transport and storage Transport Use a suitable bag to transport the device safely Storage When the device is not being used observe the following storage conditions e dry e protected from dust and direct sunlight e with a plastic cover to protect it from invasive dust if neces sary e The storage temperature is the same as the range given in the chapter Technical data e When storing the device for a long time remove the batteries Accessories Optionally the following accessories are
6. available for transport and storage e TROTEC Holster 3 For further information please contact your TROTEC customer service Operation Installing the measuring tips e Mount the measuring tips before first use A Caution Exclusively use the original measuring tips included in the scope of delivery Other measuring tips might bend or damage the holder at the measuring device 21 Remove the protective cap 21 Detach the nuts 19 Insert the measuring tips 20 in the nuts 19 Remount the nuts 19 on the device ONS Operating manual Material moisture measuring device T510 DITROTEC Inserting the batteries e Insert the supplied batteries before first use ji Caution ZN Make certain that the surface of the device is dry and the device is switched off 1 Open the cover of the battery compartment 3 2 Insert the batteries in the compartment as indicated in the figure 3 Close the cover of the battery compartment 3 The device can now be switched on Switching on Note The cross control is very sensitive Therefore avoid dirt on the control panel because it could be misinterpreted by the device as keystroke Before use make sure that the touchscreen control panel is dirt free If required clean the touchscreen control panel according to chapter Cleaning the device on page 14 1 Press the On Off key 4 until a beep is emitted 2 The device performs a short se
7. determined Reference values for the assessment of areas damaged by water In case of water damage a resistance measurement can be car ried out to enable an evaluation of the area to be dried Based on the factual moisture content and the changeable marginal condi tions the following table can be used to assess the necessity for drying by use of technical means Here one has to observe that the measurement results constitute only one component of a comprehensive damage diagnosis The experience of the evaluator and local circumstances play just as vital a role as the documentation of the measurement results The documentation further allows to demonstrate the success of a technical drying procedure Digit scale values l j Ta Insulation layers packed bed polystyrene particle foam lt 36 36 to 50 gt 50 polystyrene hard foam extruded lt 36 36 to 50 gt 50 polyurethane hard foam lt 36 36 to 50 gt 50 glass fibre lt 36 36 to 45 gt 45 rock wool or slag wool lt 36 36 to 45 gt 45 silicate foam glass lt 36 36 to 50 gt 50 cork expanded volcanic rock lt 31 31 to 40 gt 40 wood wool slabs lt 41 41 to 50 gt 50 clay fill lt 41 41 to 55 gt 55 coir lt 36 36 to 40 gt 40 Construction materials anhydrite screed lt 36 36 to 50 gt 50 cementitious screed lt 36 36 to 50 gt 50 wood cement screed lt 36 36 to 50 gt 50 xylolith lt 4 4
8. measuring the temperature of the building material ought to be in the range of 20 C e Observe disruptive influences due to electrically conducting Salts in the material Building related moisture issues often occur in liaison with water soluble salts Salts further the conductivity of con struction materials During the measurement the building material has a lower resistance value Which means that a too high measured value is displayed e Observe disruptive influences due to electrically conducting substances If a construction material contains electrically conducting substances it also has a lower resistance value which then simulates high moisture values Which means that a too high measured value is displayed From visual inspection it is usually not apparent whether there are any electrically conducting substances inside the construction material Some of the main error sources here are in particular reinforcements metal laminations and con ducting insulation such as slag in timber beam ceiling con structions Especially in case of insulation materials with metal lamination measured values are often misinterpreted during the resistance measurement Measured value assessment building moisture measure ment For the measured value assessment of building material the measurement results of the resistance measuring method can only be used as reference for a rough orientation Conclusions with respect to absolute humidity i
9. ture measuring 1 Select MAT 18 whilst in configuration mode 2 Press the OK button 10 for approx 2 seconds Code be indicated in the upper measurement value display The current material code see chapter Table of wood types is indicated in the lower measurement value display 3 Press the keys Right back 8 or Left menu 11 to select a digit The selected digit flashes 4 Press the Up 7 or Down 9 key to change the value of the selected digit 5 Repeat the steps 3 and 4 until the value is set as desired 6 Press the OK button 10 for approx 2 seconds The desired material is set The device switches to measuring mode Setting the wood temperature Please note that this function can only be selected for wood mois ture measuring Via this function you can determine the wood temperature in degrees Celsius C or Fahrenheit F The wood temperature is required by the device in order to determine the exact material moisture Note Determine the wood temperature prior to the measurement e g using a pyrometer 1 Select TEMP 18 whilst in configuration mode 2 Press the OK button 10 for approx 2 seconds The currently set wood temperature is indicated in the low er measurement value display 3 Use the keys Left or Right to select a digit The selected digit flashes 4 Press the Up 7 or Down 9 key to change the value of the selected digit 5 Repeat the st
10. use the Standard software functions please proceed to step 3 2 In order to enable the Professional functions connect the TROTEC USB dongle to a free USB port on your PC The TROTEC USB dongle Professional is automatically detected by the operating system If you only connect the TROTEC USB dongle Professional to your PC after starting the PC software click the Parameters menu item in the PC software Afterwards click the USB symbol dongle check to read the connected TROTEC USB dongle Professional 3 Switch on the device see chapter Switching on on page 5 4 Start the MultiMeasure Studio software Information regarding the use of the MultiMeasure Studio soft ware is provided in the help text of the software Errors and faults The accurate functionality of the device was tested during pro duction a number of times However if functionality faults do occur then check the device according to the following list The device does not switch on e Check the charging status of the batteries Change the bat teries when the message Batt lo is displayed upon switch on e Check that the batteries are properly positioned Check the polarity is correct e Never carry out an electrical check yourself instead contact your TROTEC customer service Maintenance For maintenance or repair work which requires the A housing to be opened contact TROTEC customer service Devices which have been opened unlaw
11. using the 19 red ironwood professional version of the PC software 20 oak holm 91 ash white American Installing the PC software 22 cocus wood granadillo 1 Download the current PC software from the Internet To do 23 bamboo dark melamine faced chipboard so visit the website www trotec de First click on Service 24 doussie Afzelia followed by Downloads and then Software Select the 25 iroko African teak kambala MultiMeasure Studio Standard software from the list If you 26 ebony African black want to use the optionally available professional version of al Cork cnipooard phendlic resin _ _ the PC software MultiMeasure Studio Professional dongle one wooo es aed aa then get in touch with your TROTEC customer service 30 see table of wood types printed version 2 Double click on the downloaded file to start the installation 31 see table of wood types printed version 3 Follow the instructions of the installation wizard 32 see table of wood types printed version 33 see table of wood types printed version 34 see table of wood types printed version 35 see table of wood types printed version 13 Operating manual Material moisture measuring device T510 DITROTEC Starting the PC software 1 Connect the device to your PC via the USB connection cable provided in the scope of delivery s Za Note Step 2 only needs to be performed when using the Professional software functions If you only
12. 1 to 55 gt 55 plaster lt 31 31 to 40 gt 40 j dry no drying required k threshold drying may be reguired after evaluation of the damage characteristics s thorough moisture penetration drying by use of technical means required All values are approximations and without warranty Operating manual Material moisture measuring device T510 DITROTEC Table of wood types The tables of wood types included in the scope of delivery con tains approx 200 types of wood with their corresponding material codes The following tables contains all the material codes stored within the device incl typical examples of wood types Material code Wood type H examples 1 pine pitch pine control code 2 Cembra pine 3 Meranti dark red 4 poplar silver white poplar 5 birch yellow silver sweet black wood fibre insulating boards cherry 6 spruce Norway 7 chipboard urea wenge maple sycamore Scottish maple acer sugar maple aca cia yew alder ash spruce Central Europe chestnut sweet 8 buckeye mahogany sapele Philippines Meranti light red walnut plum pine red robinia locust elm Kauramin chip board cypress 9 larch limba 10 Gaboon mahogany genuine big leaf Okoum walnut American black Padauk plane 11 woodfibre hardboard lime basswood 12 Douglas fir oak red oak northern red English oak dur mast oak Oregon pine 13 r
13. OTEC Technical data Parameter Value Model T510 Dimensions L x W x H 174 mm x 63 mm x 35 mm Weight approx 300 g Measuring range for building moisture Measuring range 0 to 100 digits Resolution 1 digits Measuring range for wood moisture Wood moisture 0 to 100 M Tolerance based on the measuring princi ple 0 to 5 M 0 8 M 5 to 30 M 0 2 M 30 to 100 M 0 1 M Resolution 0 1 M Operating temperature 0 C to 50 C with lt 90 or lt 20 g m non condensing Storage temperature 20 C to 60 C with lt 90 or lt 20 g m non condensing Battery 4 x Alkaline LR6 AA batteries 1 5V or NiMH rechargeable batteries gt 2500 mAh Optional power supply 5 V USB Current consumption active Approx 80 mA Current consumption passive Approx 70 pA Battery lifespan active gt 30h Scope of delivery The scope of delivery includes e 1 x Material moisture measuring device T510 e 4x Alkaline LR6 AA 1 5 V batteries e 1xUSB cable e 1x Protective cap for measuring tips e 10 x Measuring tips e 1 x Table of wood types printout e 1 x Display protection film e 1 x Getting started guide e 1 x Factory test certificate Safety Carefully read the operating manual before using the device and keep it within reach e Do not use the device in atmospheres containing oil sulphur chlo
14. TRT BA T510 TC 001 EN OPERATING MANUAL MATERIAL MOISTURE MEASURING DEVICE T510 Pian T510 o o J a MADE IN GERMANY gt TROTEC AT WORK DITROTEC Table of contents Notes regarding the operating Manual ccceseseeeeeees 1 Information about the CeVICE csccccessssesssssssessseeteeeees 2 Technical data cccccsscesessssssssesseessesssssescerseessesensesseeaees 3 OATELY cee ged g stol aka tn ada na u nku shee Va tm a Ba a k ua n n 3 Transport and storage cccscscccssssessessessessesssesesersessessrsenees 4 UO OF AU OM sczce SPR E E E P P O 4 Measuring principle c csccscesessessscescessssessessrssessssersenseaes 9 Table of wood tyP S ccccescecssscsesssssescssssessseeseessessserseteeseees 13 PC SO WATE ee 13 Errors and faults ccccccecsssssssssscsssssesssessesessessessessesssesseseeees 14 MalilG NANCE ec sscecheesesexceccizedtcsstees otec eo eaea vue edk nk k 14 DISPOSAl 565525 ozn aa ast ee ee eee ee 15 Declaration Of conformity e e eeeeeeeeeeeee eee rene 15 Notes regarding the operating manual Symbols A Danger Warns of a hazard which can lead to personal injury Caution Warns of a hazard which can lead to damage to prop erty The current version of the operating manual can be found at www trotec de Legal notice This release replaces all previous versions No par
15. ate from the actual moisture contents It is however not possible to put a pre cise number on these deviations even though the princi ple related accuracies with 0 1 M suggest a higher accuracy than for the medium measuring range from 6 to 30 M When looking at both error sources one can conclude that the resistance measurement method is particularly well suited for the determination of the moisture content between 6 and 30 M Notes regarding the wood moisture measurement e Make sure you have set the correct type of measurement wood e Make sure that the correct material code was selected e Prior to the actual measurement process check the temperature conditions To do so for instance a pyrometer is to be used for measuring the surface temperature of the wood type which should then be compared with the wood temperature set in the device If both temperatures are identical measuring can be started If the wood temperature is higher than the value set in the measuring device a higher wood moisture than really there will be displayed as a result e When measuring sawn timber observe the instructions of DIN EN 13183 2 e Always insert the measuring tips transverse to the wood fibre direction The conductivity transverse to the wood fibre direction is low er than that in line with it Depending on the type of wood it varies by the factor 2 3 to 8 When selecting the measuring positions observe the follow ing
16. e the indication CAL 14 continues to be displayed Exiting configuration mode Configuration mode will automatically be terminated after 8 sec onds without entry You can quit configuration mode yourself anytime Please note that in such an event no changes made to the settings will be adopted 1 Press the Right back key 8 for approx 2 seconds Configuration mode will be terminated Setting the measuring mode 1 Press the keys Right back 8 or Left menu 11 until the de sired measuring mode is displayed The selected measuring mode 13 will be indicated on the display 1 CFG HOLD MAX MIN AVG ACT 13 oF C The device comes with the following measuring modes Measuring Description mode ACT Measured value in real time AVG Average value of measurements since switch on MIN Minimum measured value MAX Maximum measured value HOLD Measured value will be held Holding the measured value 1 Setthe measuring mode to HOLD The current measured value will be held and displayed The device will hold this value until the measured values are set back or the device is switched off Resetting the measured values 1 Press the OK button 10 for approx 2 seconds All previously stored measured values of the measuring modes AVG MIN MAX and HOLD will be set back All measured values are then determined anew based on the measurement proceeding in the backgr
17. ed The wood temperature is to be determined before moisture measure ment and set accordingly The measuring device comes equipped with an internal temper ature compensation The resistance curves of the selected wood type are automatically adapted depending on the set wood tem perature Error sources During resistance measurement the accuracy of the measure ment method needs to be examined Two fundamental types of error sources become apparent within the measuring range from 0 to 100 M e There is one error stemming from the measuring principle of the resistance measurement This is particularly noticeable in case of high resistance values low conductivity at less than 5 M Due to the low measuring currents the measurement value display is i a increasingly falsified by molecular attrac tion Listed below are the principle related measurement er rors Measured value Error 0 5M 0 8 M 6 30 M 0 2 M 31 100 M 0 1 M Operating manual Material moisture measuring device T510 DITROTEC e The other typical error source to be considered is material characteristics This is particularly noticeable in case of high moisture contents above the fibre saturation point high con ductivity above 30 M Owing to the irregular cellular struc ture of various wood types and the i a resulting irregular water retention within and outside of the cells these meas ured values in part substantially devi
18. eps 3 and 4 until the value is set as desired 6 Press the OK button 10 for approx 2 seconds The wood temperature is set The device switches to measuring mode Operating manual Material moisture measuring device T510 DITROTEC Setting the offset By use of CAL a single point calibration can be carried out for the selected sensor indications All sensors are already factory cali brated and have a corresponding characteristic calibration curve By stating a calibration value offset a global shift of the calibra tion curve which has an effect on the entire measuring range is performed for the single point calibration The offset value to be entered is that value by which the calibration curve will be shifted Example The displayed value is always 5 too high gt change the offset value for this measurement channel to 5 The offset value s default setting is 0 0 Please note that changing the offset value brings about an auto matic reset of the measured values 1 Select CAL 14 whilst in configuration mode 2 Press the OK button 10 3 Use the keys Left or Right to select a digit The selected digit flashes 4 Press the Up 7 or Down 9 key to change the value of the selected digit 5 Repeat the steps 3 and 4 until the value is set as desired 6 Press the OK button 10 for approx 2 seconds The offset is set The device switches to measuring mode With set offset valu
19. equipment After the end of its use please dispose of this device in a manner appropriate to the relevant legal requirements In the European Union batteries must not be treated as domestic waste but must be disposed of professionally in accordance with Directive 2006 66 EC of the European Parliament and Council of 6th September 2006 concerning batteries and accumulators Please dispose of batteries in a manner appropriate to the rele vant legal requirements Declaration of conformity in accordance with the EC Low Voltage Directive 2006 95 EC and the EC Directive 2004 108 EC about electromagnetic compatibility Herewith we declare that the T510 material moisture measuring device was developed constructed and produced in compliance with the named EC directives The c marking is found on the rear of the device Manufacturer Trotec GmbH amp Co KG Grebbener StraBe 7 D 52525 Heinsberg Phone 49 2452 962 400 Fax 49 2452 962 200 E mail info trotec de Heinsberg 31 03 2014 Managing Director Detlef von der Lieck Operating manual Material moisture measuring device T510
20. for wood moisture on the one hand and for building moisture on the other Different wood types or materials can be set for these measuring modes The device can be operated via a Capacitive touchscreen control panel When not in use an automatic switch off saves the battery Optionally different electrodes can be connected via a separately available adapter set You can connect the device to a computer by using the USB cable included in the scope of delivery Then you can extract and ana lyse your measured results with the optional MultiMeasure Studio software Device depiction No Operating element Display Cross control Battery compartment with battery cover On Off key USB interface OD or B IN Connections for measuring tips with protective cap Cross control No Operating element CTL 7 Up key 8 Right back key 9 Down key 10 OK button 11 Left menu key Display cem 12 HOLD MAX MIN AVG ACT 13 Ji 14 15 JS 16 C F 17 xo CAL 18 MAT TEMP Alarm No Display element 12 Configuration mode display 13 Measuring mode 14 Measurement value display top 15 Percentage 16 Measurement value display bottom 17 Temperature unit 18 Configuration mode Operating manual Material moisture measuring device T510 DITR
21. he device emits a short beep The following message appears on the display LoC on Key lock is activated Press the On Off key 4 again The device emits a short beep The following message appears on the display LoC off Key lock is no longer activated Configuration mode 1 Press the Left menu key 11 for approx 2 seconds The device emits a short beep The CFG symbol 12 is displayed in the upper right corner Use the Right back or Left menu key to choose from the available settings Please note that some of the settings can only be selected with a certain measuring mode crer 12 HOLD MAX MIN AVG ACT C F K CAL SENS MAT TEMP Alarm Configuration mode Lamp Description Setting brightness Available are values between 20 and 100 and AL on Switch off after 30 min unless with setting AL on SENS Selecting the sensor mode available settings are Wood and Build MAT Only available in sensor mode Wood Selection of different wood types see table of wood types TEMP Only available in sensor mode Wood Setting the value for wood temperature fixed value only no measurement value range between 20 and 60 C Alarm Setting the alarm value value range 0 to 100 digits or M CAL Setting the offset value Will be added to the measured value value range for the wood moisture measurement 50 to 50 M val
22. ice 3 Plug the two cable ends 25 of the adapter cable 23 into the adapters 22 You can now connect external electrodes example 24 to the device Observe the condition of the external electrodes and pre pare these for the measurement if required For further information on suitable electrodes please contact the TROTEC customer service Measuring principle During moisture measurement according to the resistance princi ple an electric measuring current is generated within the meas uring device which is conducted through the material to be measured by means of electrodes With an increasing water content of the measured material to be examined the resistance drops and conductivity builds up If the material to be measured has a high resistance the moisture content is low If the material to be measured has a low resistance the moisture content is high Thus moisture measurement according to the resistance princi ple is an indirect measurement method since the humidity is deduced from the conductivity of the measured material Wood moisture measurement Every type of wood has a distinct conductivity In order to take this fact into consideration for the measurement every wood type comes with a material code that can be set The wood s conductivity is further influenced by the wood tem perature In order to take this fact into consideration for the meas urement the wood temperature can also be determin
23. lf test The device name and firmware version is shown on the dis play The battery charge is indicated on the display The device is ready for operation The displayed units are based on the settings of the last uti lization Notes Note that moving from a cold area to a warm area can lead to con densation forming on the device s circuit board This physical and unavoidable effect can falsify the measurement In this case the display shows either no measured values or they are incorrect Wait a few minutes until the device has become adjusted to the changed conditions before carrying out a measurement Performing the wood moisture measurement A Danger i When handling the device there is a risk of injury due to the exposed measuring tips Always put on the protective cap when not in use Caution Never force the measuring device into the material to be measured or yank it out Applying force can lead to bending or breaking of the measuring tips A Reguirements e The device is switched on e The measurement type for wood moisture is set e The wood temperature is set e The wood type is set 1 Choose a suitable measuring position The measurement is not to be performed at places with visible deficiencies e g cracks resin pockets branches Further observe the following a 30cm C insertion depth d thickness C d o a LN a R a 2 Insert the measuring tips transve
24. lity occur and cannot be remedied with the measures in the chapter Errors and faults please get in touch with your dealer or distributor When making a warranty claim supply the device number see the rear of the device The invoice acts as warranty certificate When manufacturer s instructions or legal regulations have not been followed or after unauthorised changes to the device are made the manufacturer is not responsible for the resulting damages Changes to the device or unauthorised replacement of individual parts can drastically impact the electrical safety of this product and leads to the forfeit of the warranty Liability does not extend to damages to people or property caused by the device being used other than as described in the instructions in this operating manual Subject to changes to technical design and model changes as part of constant development and product improvement without prior notice No liability is accepted for damages resulting from improper use In such cases entitlements to a warranty are then also forfeited Operating manual Material moisture measuring device T510 DITROTEC Information about the device Description of the device The material moisture measuring device T510 enables the deter mination of the moisture content in wood and other soft building materials e g gypsum plaster according to the resistance measurement method The device comes with two different types of measurement
25. n mass M can only be drawn for measurements performed with the exact same marginal conditions and compositions of the building mate rial as indicated for the test set up in the chart below This graph was created in collaboration with the Institute of Build ing Materials Research of the RWTH Aachen IBAC and illustrates the correlation between the measured value and the mass related moisture content of the examined building materi als The presentation of the metrological results in this form now permits a proper comparison of the measured value and the actual moisture content The list is limited to the most commonly used mineral building materials The measured values relate to a reference temperature of 23 C 10 9 8 7 6 5 O 3 2 1 0 0 10 20 30 40 o 70 80 90 100 110 Key 1 Moisture content M 2 _ Measured value digits 3 C 30 37 concrete conversion not possible 4 Cementitious screed conversion CM M 1 5 to 2 5 Gementitious floating screed conversion not possible 6 Anhydrite floating screed conversion M CM Plaster The determination of the moisture content of plaster calls for sep arate examination As can be seen from the following chart the volume based moisture content of plaster changes little at air humidity values between 0 and 0 8 80 5 However when exceeding the level of 0 8
26. osewood shisham 14 beech common 15 pear beech common hornbeam European oak white oak Arizona buckeye American chestnut mecruss Lebombo ironwood olive chipboard isocyanate teak PC software Use the MultiMeasure Studio Standard PC software free standard version or MultiMeasure Studio Professional paid professional version dongle required to carry out a detailed analysis and vis ualisation of your measured results You can only use all config uration visualisation and functional options of the device when using this PC software and a TROTEC USB dongle professional Installation requirements Ensure that the following minimum requirements for installing the MultiMeasure Studio Standard or MultiMeasure Studio Profes sional PC software are fulfilled e Supported operating systems 32 or 64 bit version Windows XP from service pack 3 Windows Vista Windows 7 Windows 8 e Software requirements Microsoft Excel to display stored Excel files Microsoft NET Framework 3 5 SP1 is otherwise automat ically installed during the software installation e Hardware requirements Processor speed min 1 0 GHz USB connection Internet connection 512 MB RAM minimum 16 mahogany Gaboon 1 GB hard disk space minimum 17 Nargusta 18 bamboo light Optional TROTEC USB dongle Professional for
27. ound Measured value storage Please note that measured values cannot be saved on the device itself In order to save measured values the device has to be con nected to a PC via a USB cable using the MultiMeasure Studio software 1 Briefly press the OK button 10 The displayed measured value will be saved in the soft ware Further information can be gathered from the help text of the MultiMeasure Studio software Temperature display configuration Please note that this function can only be selected for wood mois ture measuring 1 Press the Up key 7 to switch between C and F The temperature will be displayed in the selected unit The unit 15 will be indicated on the display 1 Operating manual Material moisture measuring device T510 DITROTEC USB interface The device can be connected to a PC via the USB interface 5 See chapter PC software on page 13 Switch off 1 Press and hold the On Off key 4 for approx 3 seconds until a beep is emitted The device will be switched off Connecting external electrodes An adapter set and adapter cable are required to connect external electrodes For further information please contact the TROTEC customer service Connecting adapter set and adapter cable ut 22 25 1 Detach the nuts and remove the measuring tips if applicable 2 Screw the two adapters 22 onto the dev
28. rine or salt e Never use the device for measurements at live parts e Never perform measurements on a metal surface e Ensure that all connection cables are protected from damages e g from kinks or crushing e Protect the device from permanent direct sunlight e Observe the storage and operating conditions see chapter Transport and storage Intended use Only use the material moisture measuring device T510 to measure the moisture content of wood and other soft building materials e g gypsum plaster Here read and observe the technical data To use the device for its intended use only connect and use accessories and spare parts which have been approved by TROTEC Improper use Do not use the device in potentially explosive atmospheres or for measurements in liquids TROTEC accepts no liability for damages resulting from improper use In such a Case entitlements to a warranty are forfeited Any unauthorised modifications alterations or structural changes to the device are forbidden Personnel qualifications People who use this device must e have read and understood the operating manual especially the Safety chapter For maintenance or repair work which requires the housing to be opened contact TROTEC customer service Devices which have been opened unlawfully are void of any warranty and warranty claims Operating manual Material moisture measuring device T510 DITROTEC Residual risks M
29. rse to the fibre direction with a 30 cm distance to one of the two ends of the sawn timber If the good to be measured is shorter than 60 cm the measuring position is the in the centre 3 If possible prick the measuring tips a few millimetres into the material 4 Read the measured value from the upper measurement value display 5 Carefully pull the device out of the material by gently moving it in turns to the left and to the right Operating manual Material moisture measuring device T510 DITROTEC Performing the building moisture measurement A A Danger When handling the device there is a risk of injury due to the exposed measuring tips Always put on the protective cap when not in use Caution Never force the measuring device into the material to be measured or yank it out Applying force can lead to bending or breaking of the measuring tips Requirements The device is switched on The measurement type for building moisture is set If possible prick the measuring tips a few millimetres into the material Read the measured value from the lower measurement value display For measured values of less than 15 digits the display reads For measured values above 100 digits the display flashes Carefully pull the device out of the material by gently moving it in turns to the left and to the right Key lock 1 Briefly press the On Off key 4 during operation T
30. t of this publication may be reproduced without written permission from TROTEC The same applies for electronically processing duplicating or spreading the publication Subject to technical changes All rights reserved Trademarks are used without guarantee that they may be used freely and primarily following the spelling of the manufacturer Product names are registered Changes to construction in the interests of constant improvements to the product as well as changes to the shape and colour are reserved The scope of delivery may vary from product images This document was created with all due care TROTEC accepts no liability whatsoever for possible mistakes or omissions The only party responsible for determining measured results to be valid drawing conclusions and deriving actions is the user TROTEC accepts no claims of warranty for the correctness of the determined measured values or measured results Further TROTEC accepts no liability whatsoever for possible mistakes or damage which have been caused by utilising the determined measured results TROTEC Warranty The warranty is for 12 months Damages caused by incorrect use by untrained people or start up by unauthorised people are excluded from the warranty The device complies with the fundamental health and safety requirements of the applicable EU regulations and was tested at the factory for perfect functionality multiple times However if faults in the functiona
31. ue range for the building moisture measurement 50 to 50 digits Setting the type of measurement Here you can determine whether you want to measure wood or building moisture You can choose from the settings Wood 120 and Build 100 1 2 Select SENS 18 Press the OK button 10 for approx 2 s to confirm The upper and lower measured value displays are flashing Use the Up or Down key 9 to select the measurement type Press the OK button 10 for approx 2 seconds The type of measurement was set based on your choice The device switches to measuring mode Note How the measured values are indicated changes depending on the type of measurement e Wood moisture Upper measurement value display measured material moisture in Lower measurement value display preset material tem perature in C or F e Building moisture Upper measurement value display no indication Lower measurement value display measured material moisture in digits Operating manual Material moisture measuring device T510 DITROTEC Adjusting the display illumination The display illumination can be adjusted within a range of 20 to 100 Another available setting is AL on AL on features a brightness of 100 and deactivates the automatic switch off function 1 Select the lamp 18 whilst in configuration mode 2 Press the OK button 10 to confirm 3 Select the desired value by
32. use of the Up 7 or Down 9 key 4 Press the OK button 10 for approx 2 seconds The set value will be adopted The device switches to measuring mode Setting the alarm Here you can determine the limit value for the alarm function Upon exceeding this value the device emits an acoustic signal and the indication ALARM 18 flashes The alarm function draws on the current measured value The limit value can be determined within a range of 0 to 100 1 Select ALARM 18 2 Press the OK button 10 to confirm The upper measurement value display 14 flashes 3 Press the Up 7 or Down 9 key to activate or deactivate the alarm Onor Offwill be indicated in the upper measurement value display 14 4 Press the Right key 8 Depending on the selection the alarm is either activated or deactivated The lower measurement value display 16 flashes 5 Press the keys Right back 8 or Left menu 11 to select a digit The selected digit flashes 6 Press the Up 7 or Down 9 key to change the value of the selected digit 7 Repeat the steps 5 and 6 until the value is set as desired 8 Press the OK button 10 for approx 2 seconds The alarm was set based on your choice The device switches to measuring mode With activated alarm function the indication ALARM 18 continues to be displayed Material settings Please note that this function can only be selected for wood mois
Download Pdf Manuals
Related Search
Related Contents
Samsung RM25KGRS Felhasználói kézikönyv VoIPMaster 301 - Atlantis-Land Allgemeine Hinweise zu Hydrauliksystemen und Komponenten USS-200/USS-201 CCD Camera User`s Manual Instrução de Serviço BOSS 1 BOSS 1 T BOSS 2 BOSS 2 T PB-5 ※取扱説明書とあわせてお読みください〟 Padrão de detecção PESPONTADEIRA Copyright © All rights reserved.