Home
User`s Manual - Dias Geophysical
Contents
1. ADIA EOPHYSICAL DIAS CL Current Lockout System USER s MANUAL 7 O We highly recommend that the DIAS CL technology be integrated into a field safety system that addresses all aspects of the dangers of working with electrical equipment The DIAS CL technology is designed to be nested with a standard power ON power OFF protocol using conventional radio communication In this way the DIAS CL system provides an added layer of protection for the crew against electrocution and there will be less risk of injury as crews transition from the old transmitter protocols to the new system involving the DIAS CL technology 1 3 Interface and Indicators DIAS CL Controller The DIAS CL controller is a small rugged self contained device that can be easily and quickly deployed with minimal training The external features of the DIAS CL controller are shown in the following image of the top surface of the handheld Figure 1 DIAS CL interface layout Status Screen Screen to display the status of the system System Status the status of all units is given on the left hand side up to 10 units can be displayed The status of each is indicated as follows e S safe indicates that the user is safe to be working with the wires e C clear indicates that the user is clear of the wires and current transmission can proceed e O offline indicates that the user is offline and may not be clear this status may be d
2. as both a reference and a teaching tool and it is recommended that you read the entire document If you experience operational problems with your system please call technical support at 1 306 249 4422 1 1 Unpacking Your System Thank you for purchasing a DIAS CL system A packing list is included with your shipment that identifies all of the items that are in your order You should check your shipment against the packing list upon receipt of your shipment If you find that an item is missing or was damaged during the shipment please call Dias immediately so that we can correct the problem Following is a list of items that are included with your shipment e DIAS CL current lockout units complete with internal battery e Lanyards for each DIAS CL handheld e DIAS CM L current monitor equipped with DIAS CL lockout technology 1 2 General Description The DIAS CL is a lightweight portable technology that is designed to mitigate the risk of electrocution from the high voltage wires and electrical equipment during the course of geophysical surveying Many ground geophysical surveys involve the transmission of current at high voltage through wires that extend through the survey area and through ground electrodes Direct current resistivity and chargeability DCRC surveys often involve the laying of extensive amounts of conductive wire through the survey area Current is transmitted through this wire repeatedly through a production survey day and be
3. DIAS CL Current Lockout System USER s MANUAL GEOPHYSICAL User s Manual DIAS CL Current Lockout System Dias Geophysical Limited Cambridge Ontario N3C 3Y4 Canada Ph R N Dias Geophysical Limited N 54 Alona Avenue VIN Phone 416 795 1263 www diasgeo com sales diasgeo com innovation intellect and commitment of our team DIAS CL v 201412 All rights reserved including the right of reproduction in whole or in part in any form Dias Geophysical Limited 54 Alona Avenue Cambridge ON Canada Printed in Canada O gt DIAS CL Current Lockout System USER s MANUAL 9 m O v I lt n im gt m User s Manual Table of Contents Limited Warranty Limitations of Liability and R StrictiONns ccccccccccccessssessceceeecesseseceseeeesceseessneaeeeeeens 2 1 0 Intr ducti onein E ees eee SE cence 3 1 1 Unpacking Your SySt m ccccsssccccecessesesseaecececessesesaeseceeecesseeaaeaeceeecessesesaeseceescussuseaaeseeeeecsssessaeaeeseeess 3 12 General D scriptio Masiste congesta aenar code aeea ea e ePheeeanaddeetseacdenPanddacevel ocd ssuanacdearsenebers 3 173 Interfac and INGICATOMS azenon iea irata ea i ia a A EEEa R a AEE iea O EAR aAA 4 1 4 Field Procedur s irssi nana a some dev e E pe ee Eai 5 TS SUPDOME Aa E E T E E E AE E A E 7 Limited Warranty Limitations of Liability and Restrictions Dias Geophysical Limited hereinafter referred to as Dias warrants that for a period of 12 m
4. R s MANUAL 7 oO that become unserviceable during the course of surveys can have significant production consequences e Ensure that each crew member that will be working with the current transmission lines or that will be exposed to the current transmission wires is assigned a DIAS CL controller Job Steps IMPORTANT Each step much be satisfied before proceeding to the next step of the procedure Note Clear communications must be maintained at all times between all members of the survey crew to ensure all crew members clearly understand when power is ON and when power is OFF 1 Initialization Procedure each DIAS CL controller that will be used for the survey must be paired with the DIAS CL receiver prior to surveying This handshake process can be carried out at any location within the network but is perhaps best done at the DIAS CL receiver location With both the receiver and the controller powered on press and hold the SAFE button on the controller then press select on the receiver A successful handshake will be indicated on the left hand side of the controller at which point the SAFE button on the controller can be released 2 Each crew member must ensure they are at least 3 meters 5 m in some jurisdictions from any potentially high voltage source Once this condition is met each crew member is to push CLEAR on the DIAS CL controller The status of each crew member can be confirmed by all other crew members by
5. e and has already moved greater than 3 m away from the wire 5 m in some jurisdictions The transmitter current can be turned on only when all units have their status set to clear Tx Depress when all units have Clear status This button must be depressed to close the relay in the DIAS CM L unit to allow for transmission of current through the current trasnmission wires Normally this button is depressed by either the transmitter operator or the local current electrode operator DIAS CL Receiver The DIAS CL receiver comprises a high voltage relay a mesh network card a controller a high gain antenna and indicator lights This receiver is currently integrated with the DIAS CM current monitor system DIAS CM units that have been retrofitted to contain the DIAS CL receiver are named DIAS DM L with the L extension on the name indicating that the unit has Lockout functionality The only component that must be installed is the antenna which must be screwed into the antenna receptacle Two status LED lights indicate the status of the DIAS CL receiver If the red light is on the status is Tx and if the green light is on the status is Safe These lights are provided for the benefit of the current operator to indicate what state the DIAS CL receiver is in 1 4 Field Procedures Following is a step by step description of the procedure for use of the DIAS CL current lockout technology Definition of Terms e C
6. information in this procedure does not take precedence over legislation regarding the use of electrical systems in the jurisdiction s in which the survey is taking place DIAS CL v 201412 All rights reserved including the right of reproduction in whole or in part in any form Dias Geophysical Limited 54 Alona Avenue Cambridge ON Canada Printed in Canada ADIA PHYSICAL MND Q m O DIAS CL Current Lockout System USER s MANUAL 1 5 Support Dias Geophysical provides full support for the DIAS CL technology Technical support is available by calling 1 306 249 4422 and asking for Dias Technical Support Services Unserviceable units can be packed and shipped to the following address Dias Geophysical Limited 147 Robin Crescent Saskatoon Saskatchewan S7L 6M3 Canada Please visit our website at www diasgeo com for further contact information PHYSICAL N N G m O DIAS CL v 201412 All rights reserved including the right of reproduction in whole or in part in any form Dias Geophysical Limited 54 Alona Avenue Cambridge ON Canada Printed in Canada
7. onths from the delivery date to the original purchaser Dias products will be free from defects in materials and workmanship EXCEPT FOR THE FOREGOING LIMITED WARRANTY DIAS DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Dias obligation is limited to repairing or replacing parts or equipment which are returned to DIAS transportation and insurance pre paid without alteration or further damage and which in Dias judgment were defective or became defective during normal use Dias ASSUMES NO LIABILITY FOR ANY DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES OR INJURIES CAUSED BY PROPER OR IMPROPER OPERATION OF ITS EQUIPMENT WHETHER OR NOT DEFECTIVE DIAS CL v 201412 All rights reserved including the right of reproduction in whole or in part in any form Dias Geophysical Limited 54 Alona Avenue Cambridge ON Canada Printed in Canada DIA DIAS CL Current Lockout System USER s MANUAL SEOPHYSICAL e O 1 0 Introduction This manual is designed to provide instruction for the use and maintenance of the DIAS CL current lockout system The DIAS CL system is designed to be integrated with the DIAS 32 DCRC Direct Current Resistivity and Chargeability system The DIAS CL system is intended to augment and integrate with a well designed set of field safety practices and procedures for operation of electrical surveys This manual is intended
8. tween these transmission sessions a portion of the wire is moved by the survey crew members Because of the large areas occupied by this type of survey gt 10 km in most cases it is a challenge to mitigate the risk of electrocution particularly where traditional modes of communication fail The DIAS CL system comprises a network of personal handheld devices that provide each crew member who has one of the devices with overriding control over the electrical connection between the transmitter and the current transmission wire Status information for each crew member is entered in their handheld and transmitted through the DIAS 32 mesh network to the DIAS CM L current monitor and to the other crew members For the DIAS CL system to function as intended a DIAS CM L current monitor and a DIAS 32 system are required The DIAS CM L device is normally installed near the transmitter operator along the current transmission wire and is required to effect the override functionality of the DIAS CL system through the integrated HV relay mesh network module and controller The DIAS 32 system is required for transmission of the status information from each of the DIAS CL devices to the DIAS CM L device This transmission is carried through the DIAS 32 mesh network system DIAS CL v 201412 All rights reserved including the right of reproduction in whole or in part in any form Dias Geophysical Limited 54 Alona Avenue Cambridge ON Canada Printed in Canada
9. ue to a power off condition lack of network access or an unserviceable device e Tx transmit indicates that the current operator has authorised current transmission and the user must assume that current is being transmitted ID supplies the mesh network ID for the device Unit status displays the status of the unit using the same nomenclature as given above S C O Tx Current displays the average on time current in Amperes as recorded at the DIAS CL L unit Four buttons in the lower portion of the device provide the following functionality Power Power on off button Depress to power on Depress and hold to power off Safe To be depressed when the user is about to approach the transmitter wire It should be depressed when the user is still more than 3 m 5 m in some jurisdictions from the transmitter wire and the transmitter current is already off In rare circumstances this button can be depressed to effect shut off of the transmitter current The user should also confirm that the transmitter current is zero prior to approaching the wire and doing any work with the wire DIAS CL v 201412 All rights reserved including the right of reproduction in whole or in part in any form Dias Geophysical Limited 54 Alona Avenue Cambridge ON Canada Printed in Canada DIA PHYSICA DIAS CL Current Lockout System USER s MANUAL a 7 oO Clear Depress when the user has completed all work with the transmitter wir
10. urrent Operator crew member who will carry current wire lay wire embed current electrodes in the earth and make connections between current transmission wire and electrodes e Transmitter Operator crew member in charge of operating the current transmitter e Receiver Operator crew member in charge of operating the DIAS 32 receivers e DIAS CL Receiver Device for disengaging the path of electricity from the Current Operator This will normally be the DIAS CM L unit which embodies both the DIAS CM current monitor and DIAS CL receiver functionality e DIAS CL Controller Handheld device for remotely controlling the DIAS CL Receiver Pre survey Preparation e Prior to mobilization to the survey site determine the number of DIAS CL units that will be required for the survey We recommend 2 to 3 spares for each survey e Test the functionality of the DIAS CM L and DIAS CL controllers Pre operational Checks e Ensure that the DIAS CM L current monitor and all DIAS CL controllers are checked for battery performance on a daily basis to verify that the system is functioning properly for the intended protection of crew and equipment This is also important because controllers DIAS CL v 201412 All rights reserved including the right of reproduction in whole or in part in any form Dias Geophysical Limited 54 Alona Avenue Cambridge ON Canada Printed in Canada L ADIA EOPHYSICAL DIAS CL Current Lockout System USE
11. viewing the left side of the screen on the controller 3 The current operator confirms that all crew members have a CLEAR status 4 The current operator pushes TX and confirms the system is in the TRANSMIT state 5 The current operator radios Power ON Power ON 6 The transmitter operator radios Turning Power ON waits 5 seconds and turns on the transmitter then radios The Transmitter is ON The Transmitter is ON Each DIAS CL controller will begin to display the average on time amplitude of the current waveform 7 The current operator verifies power is on by viewing the cycling red light display from a 3 meter distance or more on the DIAS CM L receiver 8 When the receiver operator confirms that the IP Resistivity measurements are completed the receiver operator radios Power OFF Power OFF 9 The transmitter operator turns off the transmitter then radios Transmitter is OFF Transmitter is OFF 10 The current operator pushes SAFE on the DIAS CL controller before handling any equipment used for the purpose of transmitting electricity 11 Any crew member who needs to approach within 3 meters 5 m in some jurisdictions of a potentially high voltage source must push SAFE on their lockout controller and verify the system is in the SAFE state before approaching the potential high voltage source The above steps described in 2 through 11 are repeated for each transmit sequence The