Home

Sonic Irrigator DIGITAL

image

Contents

1. y eect 1005 2768viz Specification subject to amendment and correct at time of going to print
2. Compatible with Complex Instruments Cannulated Lumened Instruments General Instruments and devices Laparoscopic Instruments sonic irrigator DIGITAL Cannulated Instrument Cleaner Reliable cannulated instrument cleaning at the touch of a button Sonic Irrigation Cannulated Pulse Flush System prENISO15883 HTM2030 compliant E Zee Load Tray System compatibility Process Interlock 12 cannulated instrument connections How will Sonic Irrigation help me Cleaning is the removal of all foreign material e g soil organic material from objects It is normally accomplished with water mechanical action and detergents Cleaning must precede disinfection and sterilisation procedures AP C journal Conventional methods only clean the outside What about the inside Take bipolar forceps thin lumens laparoscopic instruments E N T orthopaedic instrumentation etc all hard to clean instruments No other equipment actually ensures that the insides are scrubbed and flushed as well as the outside By connecting the instrument to the Irrigation Flush port the sonically charged jet of fluid is directed along the inside of the instrument thus providing an efficient cleaning process M Pulsed jets of fluid Sonic Irrigation The sonically charged jet of fluid passes from the Sonic Irrigator into the instrument ensuring that both ultrasonic activity and detergent solution are delivered preci
3. E ZVYME Use quick connect distal connectors to clean inside your non ported instruments thoroughly Sizes 1 thru 18mm Red Blue Yellow and Green Assorted Box Part MED1226 4 Simple push over fitting makes quick connection to non ported or non luer instruments Choose Blue for Medium Part MED1226 2 Connect fine or delicate hard to clean instruments by using the Small Red distal connector Part MED1226 1 Use large yellow or green type distal connectors to force clean through large devices such as orthopaedic reamers and dental hand pieces Yellow Part MED1226 3 Green Part MED1226 5 The Sonic Irrigator also uses luer connectors for cleaning inside ported instruments Part MED3084 1 Instrument parts screws Caps springs etc are all contained safely by using Small Accessory Basket Part BASOIO Clean it right consistently every time Let the machine take care of cleaning ALL your cannulated or lumen instruments for Complex Instruments for Cannulated Instruments for Lumened Instruments for Ultra Fine Lumened Instruments amp Devices Metisate World Leaders in Advanced Surgical Instrument Reprocessing Technology Sonic irrigator DIGITAL 52000 series 240 VAC 50Hz Part MEDTI30 SI 2000 series 110 VAC 60Hz Part MED1130 1 SI 2000 series 240 VAC 60Hz Pa
4. a Tests your machines Construction E Actual Ambient temp set lumen cleaning Outer Casing High grade corrosion resistant E Up and Down een performance PNS M Temperature maintenance Part MED1000 3 stainless steel with brushed finish py ee Control fascia Wipe clean polycarbonate E Standby Small Accessory Basket Sound Attenuating Lid Stainless steel E Process start Instruments parts screws caps springs etc are all E Quick Drain System contained safely for processing Please note Quality Part BASO10 Sonic irrigator Digital comes complete with 1 off 2 4 metre Cold Water Hose 1 off 2 4 metre Drain Hose 1 off 2 0 metre Power Cord connected User Manual E Manufactured in the UK under Medisafe s SO9001 13485 quality programme Dealer Validated Performance Guaranteed Products E Zee load basket Part MED1018 3E Zyme 4 litres Part MED8035 Distal Quick connect connectors assorted Part MED1226 4 Ex Large Green Distal connector Part MED1226 5 Large Yellow Distal connector Part MED1226 3 Medium Blue Distal connector Part MED1226 2 Small Red Distal connector Part MED122611 Small Accessory Basket Part BASOIO Medisafe International Twyford Road Bishops Stortford Hertfordshire CM23 3LJ U K Telephone 44 0 1279 461641 Facsimile 44 0 1279 461643 Website www medisafe uk com a Email info medisafe uk com SO 9001 ISO 13485 1996 Reg no 0473 INVESTOR IN PEOPLE Mectisate lt lt
5. ex Suction Grasper Baron Suction Tubes Bower Sphenoid and Antrum Cannula Cannulated Drills Cannulated Headed Reamer Cannulated Trapezoidal Tunnel Shaper Cohen Cannula Coupland Suction Tube Coring Reamer Day Attic Cannula Duke Trocar Ear Suction Tubes Endoscopic Forceps E N T Instruments Fine Lumen Instruments Flexible Inflow Cannula System Frazier Ferguson Suction Tubes Guide Hook Hartman Eustachian Catheters Hi Flow Irrigation Sheath House Suction Irrigation Tubes Injection and Punction Needle Insufflation Needles Irrigation Suction Tube Jackson Trachea Tube Krause Nasal Snare Laparoscopic Forceps Lefort Catheters Menghini Biopsy Needles Miltex Yankauer Suction Tube Mixter Irrigating Dilaprobe Non Sheathed Interference Screws Novak Endometrial Biopsy Curette Ochsner Trocars Parallel Guide Sleeve Poole Suction Tubes Pynchon Suction Tube Reamers Orthopaedic Retractor Reverdin Needles Rotating Single Double Arthroscope Suckers Suction Backbiter Suction Downbiter Suction and Irrigation Tubes Suction Punch Suction Regulator Tibial Tunnel Cannula Veress Needles Valve Sheaths Van Alyea Antrum Cannula Van Alyea Frontal Cannula Yankauer Suction Tube Y Stopcock to list just a few How do I use Sonic Irrigation Clean up residues and deposits with 3E Zyme Medisafe s High Performance Triple Enzyme Cleaning Solution Part MED8035 T
6. range of consumables and accessories Using various Medisafe Sonic Irrigator accessories even the most delicate and expensive instruments can be cleaned with minimal handling and less risk of accidental damage One touch safety and simplicity With the single touch of a an Medisate Medisafe button Sonic Irrigator Digital f E sa DVGrTAL goes to work thoroughly S Z N 1 cleaning your instruments outperforming ALL other 4 cleaning processes inside and out 2nd Set Up Use two E Zee load baskets to improve your instrument processing time and get more from your Sonic Irrigator WORLD LEADERS IN INSTRUMENT REPROC cannulated instrument cleaner NS on gt as well e of rther Compatible with ICTMIMS Instrument Care Systems The unique ICTMIMS design provides an efficient yet easy to use instrument care containment system that will allow safe instrument reprocessing and protection for delicate instruments throughout the entire decontamination process inclusive of washing and cleaning The ICTMIMS design also incorporates an innovative flushing accessory that allows plug in connection to narrow lumen devices and Phaco hand pieces alike Simply place the instruments in the multi millipede system close the frame and place in the washer ADVANCED SURGICAL ESSING TECHNOLOGY Take a look inside Andrews Pynchon Suction Tube Anthony Suction Tube Arthr
7. rt MED1130 2 Specification Safety Using Medisafe s M Electronic thermostatic eoncumablecancd protection to prevent over accessories ensures the Dimensions temperature operation smooth operation of External Front to Back 445mm M Thermal switch off to protect your Sonic Irrigator l Width 715mm drain 40mm heater Height AS M Low fluid level protection to REAN on post prevent heat burnout and over pror EOE TE Part MED8035 E Ultrasonic overcurrent Capacity 25 litres approx 6 5 US galls approx pane Distal Conner ebie 12 cannulated instruments max a dL amp N the user to connect a wide AKIS ee M men D range of instrumentation E Fused Ultrasonic Generator e E a retro flush functions Equipment amp Performance Part MED1226 4 Compatible with E Zee Load Irrigation Plumbing Kit Basket during Sonic Irrigation iMlenwsronthe E Medisafe Horn Transducers compatibility of a wide E Cannulated Pulse Enhancement range A E i pre and post luer loc Supply Manual supply not automatic L a ie pressure 1 Bar development nominal 2 Bar max Part MED1013 3 E Variable pulse flow 0 01 11 litres per minute Enzyme Foam Spray E Cavitation 700 Bar 10 000psi let Eara eeu Spray pre soak for surgical instruments Controls amp Features Prevents post op residual E Target time set 1 30 mins soil from building up E Target temperature set ambient Part MED8050 to 60 C E Actual Remaining time set Ua ala aa
8. sely to the blockage or residue removing debris and flushing clean away E Unequalled performance The unique synergetic combination of enzymatic cleaning variable pulse eel 07 NEE FNS flushing and ultrasonic cleaning action is not found in any other ka A DEBRIS equipment or process WE Validated process One touch of a button and the Sonic Irrigator is launched into a validated cleaning process giving faithful reproduction of your known or proven process time after time each and every cycle M Less handling of delicate instruments Minimal handling means less risk of accidental damage to expensive and delicate instruments The Medisafe Sonic Irrigator even tackles hard dried on residues and debris extending instrument life therefore cutting replacement and repair bills E Ifits not clean it can t be sterilised Cleaning requires both mechanical action ultrasonic scrubbing and dilution fluid If fluid is not present at any part of the cycle cleaning will not be achieved sonic irrigator DIGITAL The Sonic irrigator DIGITAL will clean up to twelve cannulated instruments in a single 8 minute process If you haven t seen the performance call us for f the insidi information or a demonstration Interlocking lid prevents mis use Medisafe s interlocking lid system interrupts the cleaning process ensuring process ae continuity protecting both healthcare staff and patients Full