Home

SIEMENS

image

Contents

1. Siemens AG Dk Nr 252441 Edition 11 98 5 SIMADYN D Hardware User Manual ECB instructions Drives and Standard Products Motors and Drives Systems Group Postfach 3269 D 91050 Erlangen System Based Technology Edition 11 98 Siemens AG Dk Nr 252441 SIMADYN D Hardware User Manual
2. installation operation and maintenance Siemens AG Dk Nr 252441 Edition 11 98 1 SIMADYN D Hardware User Manual Warning information Definitions x QUALIFIED PERSONNEL For the purpose of this User Manual and product labels a Qualified person is someone who is familiar with the installation mounting start up and operation of the equipment and the hazards involved He or she must have the following qualifications 1 Trained and authorized to energize de energize clear ground and tag circuits and equipment in accordance with established safety procedures 2 Trained in the proper care and use of protective equipment in accordance with established safety procedures 3 Trained in rendering first aid DANGER For the purpose of this User Manual and product labels Danger indicates death severe personal injury and or substantial property damage will result if proper precautions are not taken WARNING For the purpose of this User Manual and product labels Warning indicates death severe personal injury or property damage can result if proper precautions are not taken CAUTION For the purpose of this User Manual and product labels Caution indicates that minor personal injury or material damage can result if proper precautions are not taken NOTE For the purpose of this User Manual Note indicates information about the product or the respective part of the User Manual which is essential to highlight CA
3. 3 x 54 x 85 6 mm Order No 6DD1610 0AHO 6DD1610 0AKO 6DD1610 0AH5 Weight 0 03 kg 0 03 kg 0 03 kg 5 Others 5 1 Attachments Dimension drawing 4SE 465 610 9007 00 MB 4 Edition 11 98 Siemens AG Dk Nr 252441 SIMADYN D Hardware User Manual ECB instructions 6 ECB instructions Components which can be destroyed by electrostatic discharge ECB Generally electronic boards should only be touched when absolutely necessary The human body must be electrically discharged before touching an electronic board This can be simply done by touching a conductive grounded object directly beforehand e g bare metal cubicle components socket outlet protective conductor contact Boards must not come into contact with highly insulating materials e g plastic foils insulated desktops articles of clothing manufactured from man made fibers Boards must only be placed on conductive surfaces When soldering the soldering iron tip must be grounded Boards and components should only be stored and transported in conductive packaging e g metalized plastic boxes metal containers If the packing material is not conductive the boards must be wrapped with a conductive packing material e g conductive foam rubber or household aluminum foil The necessary ECB protective measures are clearly shown in the following diagram a Conductive floor surface d ECB overall b ECB table e ECB chain c ECB shoes f Cubicle ground connection
4. 441 Edition 11 98 SIMADVN D Hardware User Manual Warning information Edition 11 98 Siemens AG Dk Nr 252441 SIMADYN D Hardware User Manual Warning information NOTEI The information in this Manual does not purport to cover all details or variations in equipment nor to provide for everv possible contingencv to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficientiv for the purchaser s purposes please contact vour local Siemens office Further the contents of this Manual shall not become a part of or modifv anv prior or existing agreement committment or relationship The sales contract contains the entire obligation of Siemens The warrantv contained in the contract between the parties is the sole warrantv of Siemens Anv statements contained herein do not create new warranties nor modifv the existing warrantv Warning information WARNINGI Electrical equipment has components which are at dangerous voltage levels If these instructions are not strictly adhered to severe bodily injury and material damage can result Only appropriately qualified personnel may work on this equipment or in its vicinity This personnel must be completely knowledgeable about all the warnings and service measures according to this User Manual The successful and safe operation of this equipment is dependent on prope handling
5. SIEMENS SIMADVN D User Manual Digital Control Svstem Program memorv submodule MS5 51 55 Edition 11 98 DK Nr 252441 User Manual Program memorv submodule MS5 51 55 Program memorv submodule MS5 51 55 01 94 Program memorv submodule MS5 51 55 09 94 Program memorv submodule MS5 51 55 05 95 Program memorv submodule MS5 51 55 11 98 Copving of this document and giving it to others and the use or communication of the contents thereof is forbidden without express authority Offenders are liable to the payment of damages All rights are reserved in the event of the grant of a patent or the registration of a utility model or design We have checked the contents of this Manual to ensure that they coincide with the described hardware and software However deviations cannot be completely ruled out so we cannot guarantee complete conformance However the information in this document is regularly checked and the necessary corrections included in subsequent editions We are thankful for any recommendations or suggestions Contents Contents Warningiinformatio ni i id aa fe 1 il Orderin intormatio i sier aa eto A aa 3 2 FUNCION descriptiomii i sisien da bid da a da b d A d a 3 3 Application Informal rial dada 3 3 1 MS55 SRAM Memory Card diee cnnanncnnnnnnnnc nn nanna anna anne cnn 3 4 technical data it ted ha tu i 4 A al el Ee en a cet te ta 4 O slaten 4 6 EGB InStrUGCtO MS A ta a a da e o a fa A 5 Siemens AG Dk Nr 252
6. UTION This board contains components which can be destroyed by electrostati discharge Prior to touching any electronics board your body must be electrically discharged This can be simply done by touching a conductive grounded object immediately beforehand e g bare metal cabinet components socket protective conductor contact WARNING Hazardous voltages are present in this electrical equipment during operation Non observance of the safety instructions can result in severe personal injury or property damage It is especially important that the warning information in all of the relevant Operating Instructions are strictly observed 2 Edition 11 98 Siemens AG Dk Nr 252441 SIMADVN D Hardware User Manual Ordering information 1 Ordering information MS5 6DD 1610 OAHO MS51 6DD 1610 OAKO MS55 6DD 1610 OAH5 2 Function description Program memory sub modules MS5 51 and MS55 are used to store the processor program The program memory sub modules are inserted at slot X50 of the PM3 PT31 PT32 PM4 PM5 and PM6 processor modules in the front panel recess The MS5 51 memory sub module has a 2 4 Mbyte flash memory to store the engineering information and 8 kbyte EEPROM for operating parameters which can be modified The flash memory is a non volatile flash memory which can be erased and programmed electrically The MS55 memory sub module has a 2 Mbyte SRAM for storing the engineering information and 8 kbyte EEPROM for op
7. erating parameters which can be changed The SRAM contents are buffered when the voltage fails via a battery inserted in the module The battery can be replaced without data loss The MS5 51 and MS55 memory sub modules are based on the JEIDA PCMCIA industrial standard for memory cards with a 68 pin connection Write PCMCIA and JEIDA protect industry standard switch 68 pin memory card 3 Application information 3 1 MS55 SRAM memory card The MS55 memory card has a lithium battery CR2325 3 0V 200mAh 23mm 2 5mm Supplier e g VARTA Batterie AG Hannover To change the battery a pointed object is inserted in the hole at the upper end of the memory card The battery holder can then be withdrawn and the battery changed Please observe the correct polarity when replacing the battery The battery must be replaced within 30 minutes to prevent data loss The battery should be changed every 13 months Siemens AG Dk Nr 252441 Edition 11 98 3 SIMADYN D Hardware User Manual Technical data 4 Technical data MS5 MS51 MS55 Connection acc to 68 pin 68 pin 68 pin JEIDA PCMCIA Storage temperature 20 to 60 C 20 to 60 C 20 to 60 C Memory 2 Mbyte flash memory 4 Mbyte flash memory 2 Mbyte SRAM 8 kbyte EEPROM 8 kbyte EEPROM 8 kbyte EEPROM Access time 200 ns 200 ns 200 ns Current drain 5V 100 mA 5V 100 mA 5V 190 mA Dimensions wxHxD 3 3 x 54 x 85 6 mm 3 3 x 54 x 85 6 mm 3

Download Pdf Manuals

image

Related Search

SIEMENS siemens siemens nx siemens healthineers siemens energy siemens careers siemens gpt siemens mobility siemens industry mall siemens logo siemens eda siemens ceo siemens industry inc siemens ind mall siemens support center siemens mall siemens plc siemens imall siemens webshop siemens support siemens breakers siemens xcelerator academy siemens gamesa siemens login siemens document library siemens healthineers careers

Related Contents

Lettre Recherche février 2014 (format PDF, 2.7 Mo)  Aspire Digital GU342G0ALEPR692C6CE User's Manual    Pan  Trevi Go 2000 WiFi  2755-2.55, Interfacing DS/DD Bare Code Decoder to PLC  Blomberg GSN 9582 XB7 dishwasher  Profinaut - Automatic Spraying Systems  歴史学専攻 シラバス  User Manual Oracle FLEXCUBE Direct Banking Corporate Inquiries  

Copyright © All rights reserved.
Failed to retrieve file