Home

DeCyder 2D Software - GE Healthcare Life Sciences

image

Contents

1. Installation Uninstallation e A Installation Guide E Installation Guide S d L _ DeCyder Database 2 DeCyder 2D Oracle Server a DeCyder 2D 7 0 Database nsta Note Ifthe DeCyder 2D Software Installer dialog is not opened browse to the root of the DVD and double click on setup exe to display the dialog 3 Click Next gt in the InstallShield Wizard dialog i DeCyder 2D Outer 20 Gracin Server Ton iaae Wied ell stall feet ter ED ae Or Ale Compaen Ve cer r 7 4 Destination Folder DeCcyder 2D Click Next to install to this folder or click Change to instal a different folder Er Press Details for disk space information available Details For the currently selected volume EE net _ 12 DeCyder 2D Software Installation Guide 28 9414 48 Edition AA Installation 3 e Tochange destination folder click Change and browse for a new destination folder e Click Details to get information of available disk space on the currently selected volume Click Next gt 5 Click Install to start the installation Ready fn Kastallthe Frage am Thee miaa at aade ba banger area adler Tick etal bo page the mat alanon pratala mapy baba HI manures F puami orraa See yf po Pete seg Sick bri ki iren to ear tha milie d During the installation the status window indicate progress The installation may take 30 minutes 6 If there is a firewall installed in the computer click Unblock or simil
2. package 2 3 2 Regional settings The regional settings must be US English to ensure that the number date and time formats are correct Note You may use other keyboard layouts than the US English keyboard layout 1 Select Start Control Panel Regional and Language Options 2 Inthe Regional Options tab select English United States in the dropdown list and click OK Regional and Language Options Regional Options Languages Advanced Standards and formats This option affects how some programs format numbers currencies dates and time Select an item to match its preferences or click Customizegay your own formats English United States Samples Number 123 456 789 00 Curency 123 456 789 00 Time JASEN Short date i9 725 2008 Long date Thursday September 25 2008 Location To help services provide you with local information such as news and weather select your present location A v DeCyder 2D Software Installation Guide 28 9414 48 Edition AA 9 2 Installation preparation and requirements 2 3 Computer settings 10 2 3 3 System properties and hard drive settings 1 2 5 Select Start Control Panel System Select the General tab in the System Properties dialog Check that the computer has at least e Windows Vista Business x86 Service Pack1 English Language or Windows XP Professional x86 Service Pack 3 English Language or Windo
3. Finish to complete the installation imiaihiii Wiradi Compkrheri DeCyder 2D fhe Fertai vile then atoh Fer abbi aaa Program ieh Preto asi tha eared oo E Bai E a panii pa onary the Deber 20 appbcatiore bi iiitiiary b Brea bl kanit aroi Dni piir uier ceded Lien n rid h bha Liser daima aior Tod 9 Restart the computer when prompted 10 If you have more than one database server continue with section A 1 3 7 Creating new user s for DeCyder 2D Before using DeCyder 2D you have to create a user 1 Click the Start User Administration Tool button in the DeCyder 2D Software Installer dialog 2 Carefully read the license agreement Click Yes to accept the license agreement a Baa agree t m Bog Pgp pepe kay te rod Bee eed si Be eee P L ee Geet em rom LEPE CeCe 1 Baad F NTA PLEA me CARL IL G SSS WIGESEE dommit LUKTEN al YO ALNO MAIERS dele bil dip CSi jF THE thani paa CIH T ea i3 sive Hi Canles renal aw ta zT TETE TOPS Oe PRC UGEN GRET mea komt Te aa a That et CT rata i LEC CEM acRaneEAT Taani CHE HOT TO THH THE RA Note To beable to create users for network installation the database must be installed For network installation If the DEFAULT_ADMIN username or password has been changed from the default settings the updated settings are needed to login 18 DeCyder 2D Software Installation Guide 28 9414 48 Edition AA Installation 3 3 Click Login to login using the defau
4. GB for backup export and raw images Standalone C drive at least 10 GB free space for DeCyder 2D 7 0 computer Software D drive at least 60 GB free space for Oracle database server and data E drive at least 50 GB for backup export and raw images Application terminal C drive at least 10 GB for DeCyder 2D 7 0 Software Note Avoid running other programs with high memory requirements at the same time as DeCyder 2D 2 3 Computer settings 2 3 1 Administrator rights Before installing check that you have full administrator rights on your computer 1 Select Start Control Panel User Accounts User Accounts Users Advanced Fe Use the list below to grant or deny users access to your S computer and to change passwords and other settings Domain SEWOooo2 SEwoOoo2 Administrators SEWOooo2 Users SEwoO002 Guests Password For Administrator C To change the password For Administrator click Reset Password Reset Password 8 DeCyder 2D Software Installation Guide 28 9414 48 Edition AA Installation preparation and requirements 2 2 Check that the account name that you used for log in is marked as Administrators in the Group column Note Omitting this step can have major consequences later when installing DeCyder 2D database If you are not an administrator you will not be able to register essential files properly and installation will fail forcing you to uninstall the complete DeCyder 2D Software
5. HOST COMPUTERNAME PORT 1521 CONNECT_DATA SERVER DEDICATED SERVICE_NAME DECYDER Replace DECYDER with your own alias This alias will be shown in the login dialog when selecting database Replace COMPUTERNAME to the name of the database computer IP address can also be used if the IP address is static Save the file DeCyder 2D Software Installation Guide 28 9414 48 Edition AA 31 ADatabase connecting and customizing A 2Customizing the database A 2 Customizing the database For advanced users it is possible to customize database settings This instruction continue from step 4 in 3 5 page 14 1 Tick Advanced setup type and click Next gt ie DeCyder 2D Database InstallShield Wizard Setup Type Choose the setup type that best suits your needs Please select a setup type Standard Installation uses predefined values for Database identification Advanced ou can define custom Database setup Recommended for dyvanced users 2 Enter a database system identifier SID maximum 8 alphanumerical and click Next gt ie DeCyder 2D Database InstallShield Wizard Database identifier Set database SID Please specify the database system identifier SID IDECYDER max 8 alphanumerics 32 DeCyder 2D Software Installation Guide 28 9414 48 Edition AA 3 4 5 Database connecting and customizing Check that the desired destination folder is selected To change destina
6. THE DOWNLOADING AND OR INSTALLATION OF OR USING THIS SOFTWARE OPENING Y 1 accept the terms in the license agreement J I do not accept the terms in InstallShield e ee Click Next gt to continue DeCyder 2D Software Installation Guide 28 9414 48 Edition AA Installation 3 5 Check that the desired destination folder is selected ie DeCyder 2D Program InstallShield Wizard Destination Folder Click Next to install to this folder or click Change to install to a different Folder Press Details for disk space information available i Details for the currently selected volume METTE TE core e To change destination folder click Change and browse for a new destination folder e Click Details to get information of available disk space on currently selected volume Click Next gt 6 Click Install to start the installation fe Heady tu Baskal the Progr ane Betyder 30 The mina amity Do baban ret alae KA brka Ch Fegi l bea peg thp teat alar F poo ai tp eve on Chee yf pour Phaeton ittri cick Back ki Dreni to out the iad During the installation the status window indicate progress The installation will take some time 7 During installation on a network computer enter the DeCyder 2D server computer name in the dialog below and click Next DeCyder 2D Software Installation Guide 28 9414 48 Edition AA 17 3 Installation 3 7 Creating new user s for DeCyder 2D 8 Click
7. 9414 48 Edition AA Installation 3 8 For users that shall be able to add and remove users etc select application User Administration Tool and check User Administrator JOSH Full name John Smith M Acco is locked Position __p_R r E mail poo Phone number Login pead p_6F Generate password Select application Select Password profile User Administration Tool Default Standard Profile Accert groupe tor User Administration Toot Password expier 30 days Lock account alter 3 bad logon Grace time when 5 days pasword has expred User Administator OF Cancel 9 Copy the password normally including several special characters before continuing to make it easy to login to DeCyder 2D the first time You will have to change password at the first login Note By default the password expires after 90 days the account is locked after 3 login attempts with incorrect password and can only be opened again by a User Administrator 10 Finish by clicking OK and close the dialog TIP Add an extra user with unlimited access and without password expiry Note To have a secure DeCuyder installation change the password for DEFAULT ADMIN DeCyder 2D Software Installation Guide 28 9414 48 Edition AA 2l 3 Installation 3 7 Creating new user s for DeCyder 2D 22 DeCyder 2D Software Installation Guide 28 9414 48 Edition AA eLicense installation and activation 4 4 ekLicense installation and activation De
8. Cyder 2D Software Installation Guide 28 9414 48 Edition AA eLicense installation and activation 4 4 Inthe homepage that opens enter the Access Code and press Login to open the Software Licensing System home page pe r g i al F yy ia Ty rme f FB tere ot tat on Se Pees io hie GE Healthcare Note You can also find the homepage via http www elicensing amershambiosciences com gtlweb login 5 Collect the License file according to the instructions on the web site Paste the Computer Ethernet Address where appropriate Help amp FAQ Click the Help amp FAQ button in the dialogs for more information 6 Place the license file in the license folder normally C Program Files GE Healthcare eLicense server Licenses See Appendix B 3 for details 7 Restart the computer The license is ready to use for DeCyder DeCyder 2D Software Installation Guide 28 9414 48 Edition AA 21 4 eLicense installation and activation 44 Unavailable eLicense 4 4 Unavailable eLicense 1 If the requested eLicense is not available when you open DeCuder 2D 7 0 Program the DeCyder License Manager dialog is displayed l DeCyder License Manager 1 Information about current license status The available license s gives access to DIA and BVA 7 0 No EDA 7 0 No Details 2 Please update your license settings and restart DeCyder License Server Host Name localhost Start DeCyder 2 Enter the License Server Host Name the comp
9. Cyder 2D require an electronic license eLicense A concurrent license also called floating license is used for DeCuder 2D This license can be used by all computers connected via network to a computer running a license server This type of license is useful when many users but not all at the same time need access to DeCyder The number of computers that simultaneously can use DeCuder depends on the license The license s is administered via the license server The license server can be installed on any computer in the network but the license file must be placed on the computer running the license server All computers running a DeCyder 2D program must be connected on the same network as the computer that you install the eLicense server program on To activate DeCyder 2D you must install the eLicense server program receive the access code collect and place the license file on the computer running the license server program and launch DeCuder 2D 4 1 Preparations If you have a fire wall activated on your computer specific ports need to be open to allow for eLicense communication between the eLicense server and the computers running DeCuder 2D For more information see the ReadMe file DeCyder 2D Software Installation Guide 28 9414 48 Edition AA 23 4 eLicense installation and activation 4 2 Installation of GE Healthcare eLicense Server Program 4 2 Installation of GE Healthcare eLicense Server Program e f you previously have inst
10. GE Healthcare DeCyder 2D Software Version 7 0 Installation Guide Contents Introduction 1 1 About DeCyder 2D Software oe ccsccscssssstcessecsscsnsessessseseeeaes 5 1 2 Documentation files ee eescscstccsscstscsecssscsecessessscsecesscsseeecenes 6 1 3 Upgrade of Decyder 2D 6 5 to DeCyder 2D 7 0 cee ceeceeeees 6 14 UNINStGUGUON ssie ile eas 6 Installation preparation and requirements 2 1 Computer requirements cscstis sec el ecrtaiie iene ala aes 7 2 2 Recommendations for free space on the computer 8 2S Computer SCULING S oreren N A AN 8 Zl AOUS OOTO aaa E ET T Orcat eaten aati 8 Zae Redona SCUNAGS arne eE TOENE 9 2 3 3 System properties and hard drive settings ceccecscseecssssseesseesseeen 10 Installation 3 1 Before starting installation eseoseesesossesosseesossesossessesorsossessesos 11 3 2 Network installation ccsccssscssstccsscessesscssssssesssescsssseesesseees 11 3 3 Standalone installation 00eooesoososoesossesseseesessesossessessesorsesessessos 11 3 4 Oracle server installation cccssccsccssessssscssessecscssscsseesseees 12 3 5 DeCyder 2D 7 0 Database installation cc sescesesteeseeeeeees 14 3 6 DeCyder 2D Program installation csccsessesscsscesseerecseeees 15 3 7 Creating new user s for DeCyder 2D ssesessessssesesossesessesosssseses 18 eLicense installation and activation 41 Preparatio
11. Shield Wizard dialog Welcome to the iretaltshiald Winard lor nll DeCyder 2D necyier 20 Databarn ae ry ai rg Thon Daish D i r l Pahal Di ie E a i fehep Tepe Ohops Pa at Cpe Pak Geet a ha reie Pipes sabkt p petap Cypr Pipari ia Taldeen un pede ed va for Database dent era D dkdbyarenedd a You fan fre odia Dist ated iip Pech bee fear Lie For advanced users it is possible to customize database settings see section A 2 for a description 14 DeCyder 2D Software Installation Guide 28 9414 48 Edition AA Installation 3 5 Click Install to start the installation Read tn baiak the Prag ami The eater amity bo beg ret alam ch retell to bagn the inetiistion batalhon may hake 3 marche 2 pow snl fe eee oo eee ey of pour Peale etingi cick Back ki Caren to bur the milad During the installation the status window indicate progress The installation may take 30 minutes 6 Click Finish to complete the installation DeCyder 2D am Pe reset erate end el 3 6 DeCyder 2D Program installation Install DeCyder 2D 7 0 Program on the computer s During installation Microsoft NET Framework v 1 1 will be installed if not already installed When installing DeCyder 2D Program on a computer that will work as a network application terminal an Oracle client installation will automatically be done 1 If not already inserted insert the DeCyder 2D Software Installation DVD DeCyder 2D Softw
12. The DeCyder Uninstaller can uninstall Oracle DeCyder 2D database DeCyder 2D program and License Server for version 6 0 6 5 and 7 0 Uninstall DeCyder 2D Program To complete the uninstallation the computer must be restarted To restart the computer now select OK else select Cancel to perform the reboot manually later Systems Inc Any use of this s Healthcare Stand License Agreem dlavase VETOES UTI Stoning Software Products Uninstall Oracle Server GE Healthcare Life Sciences AB a ee cae g General Electric Company Warning Uninstall of Oracle Server will also remove the DeCyder 2D Database and all DeCyder 2D data will be deleted 2008 General Electric Company All rights reserved Uninstall selected software 30 DeCyder 2D Software Installation Guide 28 9414 48 Edition AA Database connecting and customizing Appendix A Database connecting and customizing A 1 Connect the application terminal to the database If you have more than one database server each application terminal must be connected to the correct network computer with the DeCyder database 1 To connect the application terminal client to the database find the file tnsnamnes ora on the application terminal The default location is D oracle product 10 2 0 db_1 NETWORK ADMIN tnsnames ora Add the following rows to the file for each new database that the application terminal will use DECYDER DESCRIPTION ADDRESS PROTOCOL TCP
13. alled a GE Healthcare Software Licensing Server on a computer on your network continue from Section 4 3 1 e Ifthe licensing server is not installed follow the instructions below 1 Insert the DeCyder 2D Software installation DVD 2 Click Install Software License Server in the DeCyder 2D Installer dialog m DeCydear 20 Softerare Installar Tne Urensiallation ral Ss cstalation Guide a Jena ae D Uetyder tebase i Delyder 20 Oreck Server mal Detyder 20 70 Database malh Delyder Program Detayder 20 70 Progra matalo 36 dar ags k License Server and License Acthaidon Decyder is a trecemaric of G Software Licance Server heta Heathosre Ce Adobe and Adobe Reader d inicemarke ai Adobe Lenin Ae alien Horne Dyrene Comput a Ethan Auddrisies Note Ifthe DeCyder 2D Software Installer dialog is not opened browse to the root of the DVD and double click on setup exe to display the dialog 3 Click Next in the Installation Wizard dialog fe Welooren bo ihe Invtalhiede Wigan for GI bieallhrare Solleere Linerning Server Thai a heki i Watered oul tell GE Heathen aa Leeruing Taree arma a Taea chick hit WEA The pray a poistel be cogent Lee are wder kesimi 4 Cee rat in ider ich Raped ho pr ip chee Pokies oe chek Changa on matal po a deara Poi uy F GE Hearn Se et Lice Serer hk CoP ya Py Heahea hand re a 24 DeCyder 2D Software Installation Guide 28 9414 48 Edition AA eLicense installation an
14. ar if another dialog is opened to allow installation Windows Security Alert x ike Ta olp probet yoan Ceeepeybor Window Fios har blocked AD rome jesinrer of the popam Do pou want to keep blocking thie piagam Home jaie Publisher Unknown ee tse J saree Winders Fraval hae hacked the popen bom cipro onneen hom the interme c reirei rE a E a a a aa unblock i when houk unblock 9 mogga 7 Click Finish to complete the installation fi i DeCyder 2D Software Installation Guide 28 9414 48 Edition AA 13 3 Installation 3 5 DeCuder 2D 7 0 Database installation 3 5 DeCyder 2D 7 0 Database installation Install the DeCyder 2D 7 0 Database on the computer that will work as a network database server or on the computer for standalone use This installation package will create a DeCyder 2D 7 0 Database and install the Database Administration Tool 1 If not already inserted insert the DeCyder 2D 7 0 Software Installation DVD 2 Click Install DeCyder 2D 7 0 Database in the DeCyder 2D Installer dialog W DeCyder 2D Software Installer n Installation Uninstallation y in E Installation Guide Installation Guide S d y p KA 3 DeCyder Database DeCyder 2D Oracle Server Installed 3 DeCyder 2D 7 0 Database Note Ifthe DeCyder 2D Software Installer dialog is not opened browse to the root of the DVD and double click on setup exe to display the dialog 3 Click Next gt in the Install
15. are Installation Guide 28 9414 48 Edition AA 15 3 Installation 3 6 DeCyder 2D Program installation 2 16 Click Install DeCyder 2D 7 0 Program in the DeCyder 2D Software Installer dialog i DeCyder 2D Software Installer Installation Uninstallation yt ms E Installation Guide i Installation Guide lt S r wl 3 DeCyder Database DeCyder 2D Oracle Server Installed DeCyder 2D 7 0 Database Installed DeCyder Program DeCyder 2D 7 0 Program 36 imagination at work Note Ifthe DeCyder 2D Installer dialog is not opened browse to the root of the DVD and double click on setup exe to display the dialog Click Next gt in the InstallShield Wizard dialog fix DeCyder 2D ben WARRE That praya i pentecbed bp anne wierre k Carefully read the License Agreement Accept the stated license terms by ticking I accept the terms in the license agreement i DeCyder 2D Program InstallShield Wizard License Agreement Please read the Following license agreement carefully GE HEALTHCARE STANDARD SOFTWARE END USER LICENSE AGREEMENT FOR LIFE SCIENCES SOFTWARE PRODUCTS IMPORTANT PLEASE READ CAREFULLY THIS IS THE LICENSE AGREEMENT THAT END USER IS REQUIRED TO ACCEPT BEFORE INSTALLING AND USING GE HEALTHCARE SOFTWARE CAREFULLY READ ALL OF THE TERMS AND CONDITIONS OF THIS LICENSE AGREEMENT BEFORE EITHER A OPENING THE SEALED PACKAGE CONTAINING THIS SOFTWARE AND OR B PROCEEDING WITH
16. d activation 4 5 Click Install to start the installation Ready iin beatak kha Pree a Th anar a aa ba bagan ment alang Tekita bege ih inetalation F pow el iere Gee ay pour badaio itgi dek Bad i Doei to bur ha mila d 6 ihitai Wiper Competed That EretadiSheetd banard hae muccneuly abebed Ce Peaki boas Lire Gece Ci Prah jp aout the i i 4 3 Activation of GE Healthcare eLicense Server Program 4 3 1 Receiving the access code After ordering the DeCyder 2D 7 0 Software a letter including an access code will be sent by courier to the orderer s shipment address Store the access code in a safe place The access code is necessary for collecting the eLicense files Note Ifthe access code has not been delivered within 7 days of the order contact technical support to get the access code via telephone DeCyder 2D Software Installation Guide 28 9414 48 Edition AA 25 4 eLicense installation and activation 4 3 Activation of GE Healthcare eLicense Server Program Collecting and saving an eLicense file Note You can use any computer with contact to the internet to collect the eLicense file and then transfer the file to the correct computer Insert the DeCyder 2D Software installation DVD To simplify in later steps mark the Computer Ethernet Address in the DeCyder 2D Installer dialog right click and select Copy DeCyder 2D Software Installer eee Se b4 r E p Miti Mi 36 imagination at work DeCyd
17. e e license server ait To confirm that the new set of licenses has been accepted and are available as expected select the Server Status tab and press the Perform Status Enquiry button Then scroll to the bottom of the text box The information given here will confirm that the License has been accepted and the License Server is operable see the screen dump in step 1 Select File Exit DeCyder 2D Software Installation Guide 28 9414 48 Edition AA For contact information for your local office please visit www gelifesciences com contact GE Healthcare Bio Sciences AB Bj rkgatan 30 751 84 Uppsala Sweden www gelifesciences com decyder imagination at work GE imagination at work and GE monogram are trademarks of General Electric Company CyDye DeCyder and Ettan are trademarks of GE Healthcare companies All third party trademarks are the property of their respecive owners DeCyder includes an Oracle 10g database Copyright 1995 2007 Oracle Corporation All rights reserved Third Party Credit statements Oracle is a registered trademark of Oracle Corporation and or its affiliates This product includes the Xerces XML parser Copyright 2000 The Apache Software Foundation http www apache org All rights reserved This product includes parts developed using ITK Copyright 1999 2003 Insight Software Consortium for licensing information see http www itk org Parts of this product implement the libTi
18. er is a trademark of GE Healthcare Companies Adobe and Adobe Reader are trademarks of Adobe Systems Inc Any use of this software is subject to GE Healthcare Standard Software End User License Agreement for Life Sciences Coafhware Drachicto Installation Uninstallation Installation Guide Installation Guide DeCyder Database DeCyder 2D Oracle Server Installed DeCyder 2D 7 0 Database Installed DeCyder Program DeCyder 2D 7 0 Program Installed License Server and License Activation Software License Server icanee Arti Computer Ethernet Address 00142224365D Note Ifthe DeCyder 2D Software Installer dialog is not opened browse to the root of the DVD and double click on setup exe to display the dialog 3 Click License Activation Homepage in the DeCyder 2D Installer dialog D DeCyder 2D Software Installer aia rs 36 imagination at work DeCyder is a trademark of GE Healthcare Companies Adobe and Adobe Reader are trademarks of Adobe Systems Inc Any use of this software is subject to GE Haaskhaara Ctancdeara Cathwara Enel lear 26 Installation Uninstallation Installation Guide Installation Guide DeCyder Database DeCyder 2D Oracle Server Installed DeCyder 2D 7 0 Database Installed DeCyder Program DeCyder 2D 7 0 Program Installed License Server and License Activation Software License Server License Activation Homepage Computer Ethernet Address 0014222A365D De
19. ff library Copyright 1988 1997 Sam Leffler Copyright 1991 1997 Silicon Graphics Inc http www libtiff org Parts of this product include NMath components from CenterSpace Software LLC Copyright 2002 2008 All rights reserved http www centerspace net Parts of this product include components from Farpoint Technologies Inc Copyright 1991 2007 All rights reserved http www fpoint com Parts of this product include the TeeChart component from Steema Software SL Copyright 1995 2008 All rights reserved http www teechart com Parts of this product include the open source MD5 implementation by L Deutsch Copyright 1999 2000 2002 Aladdin Enterprises All rights reserved Parts of this product include Cool Scrollbar Library Copyright 2001 J Brown CyDuye 2 D Fluorescence Difference Gel Electrophoresis 2 D DIGE technology is covered by US patent numbers US6 043 025 US6 048 982 US6 127 134 and US6 426 190 and foreign equivalents and exclusively licensed from Carnegie Mellon University CyDuye This product or portions thereof is manufactured under license from Carnegie Mellon University under US patent number US5 268 846 and other patents pending The purchase of CyDye fluors includes a limited license to use the CyDye fluors for internal research and development but not for any commercial purposes A license to use the CyDye fluors for commercial purposes is subject to a separate license agreement
20. log LMTOOLS by Macrovision Corporation http Awww macrovision com File Edit Mode Help Service License File System Settings Utilities Start Stop Reread erver Status Server Diags Config Services Borrowing FLEXnet license services installed on this computer Start Server Stop Server ReRead License File i Force Server Shutdown Seber alei eit NOTE This box must be checked to shut down a license server when licenses are borrowed Using License File C Program Files GE Healthcare eLicense server Licenses 36 DeCyder 2D Software Installation Guide 28 9414 48 Edition AA Licensing Server administration for advanced users 5 Click the Reread License File button to update the license file information Then it displays Reread Server License File Completed LMTOOLS by Macrovision Corporation http Avww macrovision com File Edit Mode Help Service License File System Settings Utilities Start Stop Reread Server Status Server Diags Config Services Borrowing FLEXnet license services installed on this computer Start Server Stop Server ReRead License File y Force Server Shutdown ne vee NOTE This box must be checked to shut down a license server when licenses are borrowed Reread Server License File Completed 6 To confirm that the License Server is operating with the selected license select the Server Status tab and press the Perform Status Enquiry button Then scroll to the bot
21. lt admin user Username Maase Password pee Database DECYDER nore gt gt C o 4 Click New Lees darai Foii baama T 5 Enter login name full name and if desired additional information and click OK Create user account Please enter user account information Mote the Login name must be unique Login name Josh Full name John Smith Positions E mail Fhone number Cancel DeCyder 2D Software Installation Guide 28 9414 48 Edition AA 19 3 Installation 3 7 Creating new user s for DeCyder 2D 6 Click Generate password to get a temporary password Lier Adminttiration Tool Select Paaawod puie Dera baread Prete Pasereord epeen W d Lock eccound ater 3 bad logons Grace he when 5 i pasmi has capre Dk Cancel 7 Select application DeCyder 2D and check the appropriate Access groups e Scientist access to the DeCyder application only e Administrator access to the Database administration tool only e Scientist and Administrator access to both the DeCyder application and the Database administration tool JOSH R Full name John Smith Account is locked Position es E mail e Login pwd pP Generate password Select Password prolia Default Standard Profile Password expires 30 days Lock account after Eg bad logons Grace ume when 5 days password has expaed OF Cancel 20 DeCyder 2D Software Installation Guide 28
22. ngs B 3 View configuration settings 1 Click the Config Services tab to display the configuration of the eLicense server 2 The configuration displayed below should be used for DeCyder 2D Software LMTOOLS by Macrovision Corporation http Avww macrovision com File Edit Mode Help Service License File System Settings Utilities Start Stop Reread Server Status Server Dia Config Services Borrowing Configure Service Save Service Service Name GE healthcare eLicense server v Remove Service Path to the Imgrd exe file C Program Files GE Healthcare eLicense serve __ Browse Path to the license file 1 Files GE Healthcare eLicense server Licenses __ Browse Path to the debug log file C Program Files GE Healthcare eLicense serve Browse View Log M Start Server at Power Up The field Path to the license file is the directory where the floating license file should be placed The default directory for floating license files is C Program Files GE Healthcare eLicense Server Licenses Do not change the default path By default Use Services is selected to run the license server as a Windows Service By default Start Service at Power Up is also selected to automatically start the license server when the machine boots 3 Click Save Service even if you made no changes in step 2 4 Select the Start Stop Reread tab to control the license manager Information about the license file is displayed at the bottom of the dia
23. ns ssccsicersnecseseoxsecsssaccasvessaenssensevestesseteacsieea TA 23 4 2 Installation of GE Healthcare eLicense Server Program 24 4 3 Activation of GE Healthcare eLicense Server Program 25 43 RCC VING the dcce sS COU eaaa E aii names 25 4 4 Unavailable eLicense neonesesessesesoesesessesossesessesessesesossessesesessese 28 Uninstallation 5 1 Uninstallation procedure seesesoesessesossossessessesossesesorsessesessessos 29 DeCyder 2D Software Installation Guide 28 9414 48 Edition AA 3 Appendix A Database connecting and customizing A 1 Connect the application terminal to the database 31 A 2 Customizing the database cscscssssrcssssscesscesesssceeseeees 32 Appendix B Licensing Server administration for advanced users Bay Open the tool accel eee ae 35 B 2 View the Host ID of the computer ceceseeteceeeseeseeeeeeenes 35 B 3 View configuration settings ccsccssscsescesscscssscseessecesseenes 36 B 4 Change license configuration seseesesossesoeseesossessessesosseseesesses 38 DeCyder 2D 6 5 Software Installation Guide 28 4010 08 AC Introduction 1 1 Introduction 1 1 About DeCyder 2D Software DeCyder 2D Software is an automated image analysis software suite which enables detection quantification matching and analysis of Ettan DIGE system gels The two dimensional 2D electrophoresis gels are used for separating complex p
24. ommendations Section 2 2 Computer settings Section 2 3 2 1 Computer requirements DeCyder 2D Software Installation Guide 28 9414 48 Edition AA Operating System Windows Vista Business x86 Service Pack1 English Language or Windows xP Professional x86 Service Pack 3 English Language or Windows Server 2008 Enterprise Service Pack 1 English Language Note The screen dumps may differ from the appearance with Windows Vista Internet Explorer version 5 5 or higher must be installed to run the XMLToolbox module At least 2 GB RAM The computer must have a dual layer DVD reader Set the virtual memory so that the total amount of available memory including physical RAM is at least 2 5 GB Minimal free space on local hard drive for an Application terminal is 3 GB Minimal free space on local hard drive for Database server and Standalone computer is 30 GB Video card capable of 32 bit color The video card driver needs to support Open GL v 1 2 or later ensure that the latest compatible driver is installed Set the color resolution of the PC to 32 bit color 2 Installation preparation and requirements 2 2 Recommendations for free space on the computer 2 2 Recommendations for free space on the computer Type of computer Recommendations Database Server C drive at least 10 GB free space for DeCyder 2D 7 0 Software D drive at least 60 GB free space for Oracle database server and data E drive at least 50
25. re Life Sciences AB a General Electric Company 2008 General Electric Company All rights reserved wha Installation Uninstallation Installation Guide Installation Guide DeCyder Database DeCyder 2D Oracle Server DeCyder 2D 7 0 Database i DeCyder Program DeCyder 2D 7 0 Program License Server and License Activation Software License Server License Activation Homepage Computer Ethernet Address 0014222A365D Other Documentation DeCyder 2D 7 0 Getting Started Guide Software Change Description Read Me License Agreement Adobe Reader SEL Installed There is also a button for download of Adobe Reader This software enables access to pdf files and can be downloaded free of charge 1 3 Upgrade of Decyder 2D 6 5 to DeCyder 2D 7 0 If DeCyder 2D 6 5 is already installed backup the DeCyder database and then uninstall the complete software package see Section 5 before installing DeCyder 2D 7 0 1 4 Uninstallation To uninstall selected modules or the entire DeCyder 2D 7 0 Software from a computer see Section 5 Make sure to backup the DeCyder database before uninstalling DeCyder 2D Software Installation Guide 28 9414 48 Edition AA Installation preparation and requirements 2 2 Installation preparation and requirements Check that the following requirements are fulfilled before starting the DeCyder 2D installation Computer requirements Section 2 1 Computer free space rec
26. rmation and tools for the e license server program The most useful tabs are System Setting Config Services Start Stop Reread and Server Status Note Using LMTOOLS to control the license server is covered in detail in the Macrovision Licensing End User Manual B 1 Open the tool Open the LMTOOLS utility by locating the folder where the license server installation is stored and double click Imtools exe LMTOOLS opens B 2 View the Host ID of the computer The Host ID also called Ethernet MAC address identifies the computer and is used to activate the eLicense 1 Click the System Settings tab LMTOOLS by Macrovision Corporation http Avww macrovision com File Edit Mode Help Service License ri System Sotnas J tilities Start Stop Reread Server Status Server Diags Config Services Borrowing Hostid Settings Time Settings Computer H ostname DSE1 HHIBS W CC System Time Zone Central Europe Standard Time Include Domain Username cttcile GMT Time Tue Mar 22 10 53 25 2005 iala Difference From UCT 4294967236 IP Address ECET MSDOS Time TES Ethernet Address OOO fSe8c60 Local Time 1111488805 Windows Directory C WINDOWS Numb FLEXID Save HOSTID Info to a File 2 The Host ID is displayed in the Ethernet Address text box Disk Volume Serial 2416fa04 mber DeCyder 2D Software Installation Guide 28 9414 48 Edition AA 55 BLicensing Server administration for advanced users B 3View configuration setti
27. rotein mixtures labelled with up to three CyDye DIGE Fluor dyes DeCyder 2D 7 0 Software works with an Oracle database where all data is stored DeCyder 2D 7 0 Software can be used in a network or on a standalone computer Network installation Standalone installation AL O gt ES Database server Application terminals The installation includes The installation includes The installation includes Oracle 10g DeCyder 2D 7 0 Program Oracle 10g DeCyder 2D 7 0 Database DeCyder 2D 7 0 Database DeCyder 2D 7 0 Program DeCyder 2D 7 0 Program Figure 1 1 Installation types Installation of XML format descriptions Pick list MS Data is included in the DeCyder 2D 7 0 Program installation Tutorial data is included in the DeCyder 2D 7 0 Database installation DeCyder 2D Software Installation Guide 28 9414 48 Edition AA 5 1 Introduction 1 2 Documentation files 1 22 Documentation files Pdf versions of different documentation are available in the DeCyder 2D Software Installer dialog which opens after inserting the DeCyder 2D 7 0 Software installation DVD in the computer Ul DeCyder 2D Software Installer yt E sr 36 imagination at work DeCyder is a trademark of GE Healthcare Companies Adobe and Adobe Reader are trademarks of Adobe Systems Inc Any use of this software is subject to GE Healthcare Standard Software End User License Agreement for Life Sciences Software Products GE Healthca
28. server computer Section 3 5 3 Install DeCyder 2D 7 0 Program on the Database server computer and on the application terminal computer s Section 3 6 4 Connect the application terminals to the DeCyder 2D 7 0 Database Section A 1 5 Create users to DeCuder 2D via User Administration Tool Section 3 7 Standalone installation For a standalone installation all parts of the software will be installed on a single computer No network is required The installation must be made in the following order If some installation steps have already been done continue to next installation 1 Install Oracle server Section 3 4 2 Install DeCyder 2D 7 0 Database Section 3 5 3 Install DeCyder 2D 7 0 Program Section 3 6 4 Create users to DeCyder 2D via User Administration Tool Section 3 7 DeCyder 2D Software Installation Guide 28 9414 48 Edition AA 11 3 Installation 3 4 Oracle server installation 3 4 Oracle server installation Install the Oracle Server software on the computer that will work as network database server or on the computer for standalone use Note f earlier versions of DeCyder 2D Software have been uninstalled check that the Oracle folder default location D Oracle has been removed before starting the new installation of Oracle 1 Insert the DeCuder 2D 7 0 Software Installation DVD 2 Click Install DeCyder 2D Oracle Server in the DeCyder 2D Software Installer dialog w DeCyder 2D Software Installer
29. tion folder click Change and browse for desired location Click Next gt to continue ie DeCyder 2D Database InstallShield Wizard Choose Export Location Please specify a location where Database Admin Tool will place export files jap Tool will place export files to N ER cal CiiDeCyder Export Note that the selected folder has to reside on a local drive Export files can t be placed on mapped network drives ie DeCyder 2D Database InstallShield Wizard Password security settings Please enter your password seetings Set minimal password length H number between 4 and 10 The password shall include at least one character of each category Letter decimal digit Letter decimal digit special punctuation character Click Install to start the installation i DeCyder 0 Datahaoo Imetallshield Wizard Peevey bo Ter all ee Progr ac The wiradi it reach bo Bein instabat If pou want bo revita or change any of your inetallstion setings kE Deck Chek Cancel to ait the wizard DeCyder 2D Software Installation Guide 28 9414 48 Edition AA 53 ADatabase connecting and customizing A 2Customizing the database 534 DeCyder 2D Software Installation Guide 28 9414 48 Edition AA Licensing Server administration for advanced users Appendix B Licensing Server administration for advanced users GE Healthcare Software Licensing Server tools LMTOOLS is a dialog for the advanced user containing info
30. to perform a backup before continuing To uninstall all or a specific module click the corresponding check box es DeCyder 2D Software Installation Guide 28 9414 48 Edition AA 29 5 Uninstallation 5 1 Uninstallation procedure and click Uninstall selected software By uninstalling the Oracle Server DeCyder 2D Database is automatically uninstalled and all data is removed Uninstallation The DeCyder Uninstaller can uninstall Oracle DeCyder 2D database DeCyder 2D program and License Server for version 6 0 6 5 and 7 0 Uninstall DeCyder 2D Program Installed Uninstall Software License Server Installed Note Remember to store license file s on a safe place Uninstall DeCyder 2D Database Installed Warning All data inthe database will be deleted Make sure a backup has been made on the DeCyder 2D database before un installing Uninstall Oracle Server Installed Warning Uninstall of Oracle Server will also remove the DeCyder 2D Database and all DeCyder 2D data will be deleted Uninstall selected software 5 Ifuninstalling the Oracle server or the DeCyder 2D Database click Yes in the dialog that appear Uninstall DeCyder 2D Make sure that you have a backup of the database i All Oracle and DeCyder 2D data will be lost Do vou want to continue ves No 6 Click OK to finish the uninstallation by restarting the computer i DeCyder 2D Software Installer Installation Uninstallation Uninstallation
31. tom of the text box The information given here will confirm that the License has been accepted and the License Server is operable LMTOOLS by Macrovision Corporation http Avww macrovision com File Edit Mode Help Service License File System Settings Utilities Start Stop Reread Server Status Server Diags Config Services Borrowing Helps to monitor the status of network licensing activities Options Individual Daemon Perform Status Enquiry niidud Feature oo Server Name Flexible License Manager status on Wed 37 23 2005 15 58 Detecting lmgrd processes License server status Z7000 SEHC C4081B86 D License file s on SEHC C4081B86 D C Program Files CE Healthcare eLicense Server Licenses DeCyder MS 1 0 DUP_CGROUP SEHC C4081B86 D 5 Expiring 050331 lic Using License File C Program Files GE Healthcare eLicense Server Licenses DeCyder MS 1 0 DUP_GROUP SEHC C4081B86 7 Select File Exit DeCyder 2D Software Installation Guide 28 9414 48 Edition AA 57 BLicensing Server administration for advanced users B 4Change license configuration B 4 38 Change license configuration If the set of licenses needs to be changed on an e license server that is already installed and in operation perform the following steps Make sure that all licenses offered by the e license aes server are checked in All e license server users must have returned their license to the server that is closed their program windo
32. uter name for the eLicense server in your network and click Start DeCyder 3 Once the eLicense file is found the DeCyder 2D 7 0 Program will start displaying the license agreement 28 DeCyder 2D Software Installation Guide 28 9414 48 Edition AA Uninstallation 5 5 Uninstallation It is possible to uninstall the entire or selected parts of DeCyder 2D 7 0 Software Versions 6 0 and 6 5 of DeCyder 2D Software can also be uninstalled using the below procedure Note Ifthe DeCyder 2D Oracle Server or DeCyder 2D 7 0 Database is uninstalled from the Database server computer it will not be possible to use DeCyder 2D Software on the application terminals 5 1 Uninstallation procedure Before starting uninstallation of software it is essential to perform backup of the DeCyder 2D Database See the DeCyder 2D Software version 7 0 User Manual for information on how to perform backups 1 Shut down all programs 2 Insert the DeCyder 2D Software installation DVD 3 Click the Uninstallation tab in the DeCyder 2D Software Installation dialog ul DeCyder 2D Software Installer Installatid Uninstallation ALNI F Database Administration Tool A To backup the DeCyder lt Apo Sg 2D database use the 2 k Database Administration Eig Backup Database Tool a Uninstallation Note Ifthe DeCyder 2D Software Installer dialog is not opened browse to the root of the DVD and double click on setup exe to display the dialog 4 Remember
33. with GE Healthcare 2008 General Electric Company All rights reserved All goods and services are sold subject to the terms and conditions of sale of the company within GE Healthcare which supplies them A copy of these terms and conditions is available on request Contact your local GE Healthcare representative for the most current information GE Healthcare UK Ltd Amersham Place Little Chalfont Buckinghamshire HP7 9NA UK GE Healthcare Bio Sciences Corp 800 Centennial Avenue P O Box 1327 Piscataway NJ 08855 1327 USA GE Healthcare Europe GmbH Munzinger Strasse 5 D 79111 Freiburg Germany GE Healthcare Bio Sciences KK Sanken Bldg 3 25 1 Hyakunincho Shinjuku ku Tokyo 169 0073 Japan 28 9414 48 AA 10 2008
34. ws Control this by opening the Server Status tab Press the Perform Status Enquiry button Then scroll to the bottom of the text box The information given here will confirm that no license is in use LMTOOLS by Macrovision Corporation http Avww macrovision com File Edit Mode Help Service License File System Settings Utilities Start Stop Reread Server Status Server Diags Config Services Borrowing Helps to monitor the status of network licensing activities Options Individual Daemon Perform Status Enquiry areant E Server Name Vendor daemon status on seuppd t2831 gehealth UP vll 5 Feature usage info Cn I Users of DeCyder Classic Total of 40 licenses issued Total of l license in use eee DeCyder Classic v7 0 vendor gehealth Using License File C Program Files GE Healthcare eLicense server Licenses Click the Start Stop Reread tab and stop the e license ane server by pressing the Stop Server button Update the set of licenses that should be used by the e license server for example if a new license shall be added copy it to the folder where the current set of e licenses resides by default C Program Files GE Healthcare eLicense Server Licenses Please observe that all licenses in this folder must be valid and have the same vendor name in our case gehealth DeCyder Classic v7 0 vendor gehealth Inthe LMTOOLS Start Stop Reread tab press the Start server button to restart th
35. ws Server 2008 Enterprise Service Pack 1 English Language e Pentium 4 CPU 1 5 GHz e 26GB 2048 MB of RAM If the computer does not fulfill these criteria use another computer which does or upgrade the computer If desired change the name of the computer before starting the installation Select Computer Name tab change computer name and click Apply DeCyder 2D Software Installation Guide 28 9414 48 Edition AA 5 3 1 3 2 3 3 Installation 3 Installation Before starting installation e Read the Read me file provided in the Documentation folder on the DVD DeCyder 2D version 7 0 It contains late breaking information not added to the installation guide e Make sure that all requirements stated in Section 2 are fulfilled e Exit all programs on the computer Network installation For a network installation different parts of the software will be installed on different computers DeCyder 2D 7 0 database will be installed only on the Database server computer The database includes Tutorial files DeCyder 2D 7 0 Program shall be installed on the Database server itself and can be installed on any computer located in the same network as the Database server computer The installation must be made in the following order If some installation steps have already been done continue to next installation 1 Install Oracle server on the Database server computer Section 3 4 2 Install DeCyder 2D 7 0 Database on the Database