Home
Dental, Premier Dental Scaler/Polisher
Contents
1. against dropping or abuse Scaling insert warranty 90 days from date of purchase Prophy angle warranty 6 months from date of purchase 7 Specifications Size H 2 2 X W 8 6 X D 7 9 Weight 7 lbs Output power to tip Operator adjustable from approximately 30 55 watts Power supply to unit 110 125 VAC 50 60 Hz optional 220 230VAC 50 60 Hz Current 0 8 Amperes 110 220 VAC Fuse 3AG 2 0 ampere regular blow style 0 4 Amperes 220 230 VAC Fuse 3AG 2 0 ampere regular blow style Frequency Generated 25 000 Khz CPS Water flow and supply pressure 18 cc 30 cc per minute flow from insert tip Operator adjustable precision pressure regulation Supply pressure to scaler is 25 to 60 PSIG city water input or contained bottle system Poa eee
2. A B C D E F gt Clean outer surface of unit with federally approved non immersion water based cold sterilization solution then dry immediately with clean air or paper towels gt Do not autoclave detachable handpiece assembly This will void manufactures warranty A federally approved water based cold sterilization solution J833 Pink Germicide may be used to wipe down detachable handpiece assembly however DO NOT get sterilization solutions on electrical contacts of the handpiece connector as this will cause oxidation and poor electrical connection Dry all surfaces with clean air or paper towels Description and Function of Components Handpiece Receptacle Accepts male side of handpiece connector Power Control Adjusts the output of power to the insert tip Polisher Speed control Speed control for micromotor Found only in the J1080 combo units Water Control Adjusts flow of water to handpiece and insert tip rotate higher water flow to the right lower water flow to the left On Off Scaler Motor Pack selector switch located on right side of front panel switch has three positions Off when centered ON when switch is moved up or down When scaler switch is moved upward the scaler portion of the unit is activated When switch is moved downward the motor pack is activated and ready for polishing Indicator LED Lights up when toggle switch is set to scaler polisher Handpiece Assembly The handpiece assem
3. Jorgensen Laboratories Inc Premier Dental Scaler Polisher User Manual Dental models not included J1180 Scaler Polisher J1181 Scaler Jorgensen Laboratories Inc 1450 Van Buren Ave Loveland Colorado 80538 Toll free 800 525 5614 Fax 970 663 5042 Jorvet com Contents Hazards Warnings amp Sterilization Description and Functionalities of Components Installation amp Operation of Scaler and Micromotor Codes for Accessories amp Replacement Parts Troubleshooting Warranty Terms Specifications 1 Hazards Warnings amp Sterilization This equipment only to be used by a qualified veterinarian or technician Vv Vv VVWV No one with a pacemaker should operate this unit A grounded AC power cord must be used with this equipment The J1080 J1081 should be powered from a separate wall outlet with a grounding point If you plug into a GFI ground fault interrupt outlet it may trip the GFI socket due to the high sensitivity of the socket Place machine on level stable platform or surface Do not place unit on or near any source of heat Unit should be located where normal air flow will circulate freely around the case when in use this will avoid overheating Water input hose is subject to deterioration by aging chemicals in the water supply excessive flexing and pressure fluctuations As an added precaution water supply should be turned off or pressure on tank relieved at the end of the day Remember to tu
4. bly is used to accept the interchangeable insert tips It is connected to the autoscaler front panel via the handpiece receptacle Be sure to plug and unplug scaler cord carefully grasping plug itself and not the cable attachment Open end of handpiece will Accept inserts J452D1 Universal insert J452D2 Spatula Insert or the J452D1P Periodontal Insert Note Inserts are extremely fragile if one is dropped or bent it may not cavitate or function properly and may operate at a higher than normal temperature and should be replaced IMMEDIATELY 3 Installation amp Operation Guide Installing the Handpiece Assembly I Align the electrical contacts of the male connector with the same on the female panel connector IL Gently insert connector it should slide in with very little effort if the connector does not align DO NOT FORCE IT Turn connector body in either direction until connector correctly aligns and goes in easily Il Once connector has been completely inserted screw outside lock ring to the right clockwise with light finger pressure until it stops Do not over tighten lock ring Be careful not to cross thread the lock ring V To remove connector unscrew lock ring to left counter clockwise and gently pull outward grasping the entire connector body SDa Installation amp Operation of Autoscaler I Il Il VI vil Upon receipt of your unit carefully unpack and make sure that The toggle
5. cessories amp Replacement Parts J452D1 J452D2 J452D1P J1180D3 J1180D5 J452D5 J452D6 J452D4 J452D15 Universal Insert Spatula Insert Periodontal Insert Prophy angle U style Contra Angle U style latch type Prophy Polishing paste Rubber cups for polishing Portable water tank Male quick release for water tank 5 Troubleshooting If unit does not function proceed with the following I Il Il IV LED light above on off switch will not come on Solution A Check that power cord is plugged all the way into the receptacle Solution B Check replace fuse 2 amp fast blow style If fuse blows again DO NOT attempt to replace as this indicates a serious condition that must be examined by a service professional Call technical support 1 800 525 5614 Unit not Vibrating a Check power cord ensure plug is all the way into the receptacle b Try another insert If insert is not the correct one for you model it will not oscillate If scaler stops functioning or is intermittent when handpiece cord is moved Stop using immediately as cord needs repaired or replaced e Note Do Not press the foot switch as there is a possibility the internal safety fuse may blow and require replacement by a qualified technician e If handpiece service is needed Turn unit off carefully unscrew the outer lock ring of handpiece assembly and gently unplug from the front panel Call your dealer for assistance 1 800 525 5614 I
6. depress the foot pedal to become familiar with the way the micromotor handpiece operates Slowly rotate the speed control knob from the left to the right to increase speed of the micromotor This provides for a smooth progression of speeds from low of approx 450 RPM s to the high which is approaching 12 000 RPM s Not only does this unit furnish a wide range of speeds but also delivers a high degree of torque throughout the speed range V The micromotor handpiece requires no scheduled maintenance however the following suggestions should help provide optimum performance Prevent fluids water cleaning solutions lubricants etc from gaining access to the motor Keep oils and other lubricants away from the coupling otherwise slippage may occur and the prophy angle will not perform well small amount of Vaseline can be applied to the micromotor o ring to help the prophy angle and contra angle slide easily onto the motor The handpiece does not require lubrication placing oils or liquids into micromotor will cause severe damage to the motor Micromotor is not to be autoclaved Dropping the micromotor handpiece should be avoided The motor is a high speed precision product that can be permanently damaged by dropping This will void the warranty e Do not insert burs or grinding stones directly into the end of the micromotor handpiece All burs and attachments must be inserted into a latch style contra angle J1180D5 4 Codes for Ac
7. f handpiece handle or insert operates hot 10 a Reduce power and increase water flow b Check water flow for sufficient pressure level c Check water quick connector should be fully locked in place d Check water filter for debris e Change scaler insert e If problem does not resolve DO NOT CONTINUE call technical support 1 800 525 5614 V Humming or high pitch sound noted from console during use This is normal circuit resonance which will change as power control knob is adjusted should not affect the performance of your scaler 6 Warranty Information Proof of purchase such as a copy of the original invoice or bill of sale must be submitted to obtain warranty service VARIOUS PARTS HAVE SEPARATE WARRANTY DURATIONS Warranty does not include shipping and handling charges in either direction Warranty is limited to the original purchaser of the unit Warranty will not cover a unit that has been previously altered repaired or serviced by anyone other than an authorized service personnel The serial number must not be altered or removed The unit must not be subject to accident misuse abuse or operate contrary to the operating instructions Six year parts and labor warranty on all internal circuit boards 11 Two year parts and labor warranty on all other components in the device including detachable scaling handpiece and external foot pedal Polishing handpiece warranty 6 months from date of purchase No warranty
8. rn water back on prior to use the next day Do not remove external cover from the unit There are no serviceable parts inside allow only qualified technicians to service your scaler Handpiece quick connect is very strong but care should be taken not to pull with excessive force on cord It is the responsibility of the dental professional using this device to be fully trained in the proper use of ultrasonic scalers The operator must be observant of possible changes in performance during a procedure and immediately discontinue use of this product and determine the cause of such changes before continuing the dental Performance varies slightly between manufacture or ultrasonic scalers so the operator must become familiar with the operating parameters and adjustments of this particular device Performance varies between ultrasonic inserts due to style model and age of the insert gt Sterilization Manufacture recommends that all operators of this ultrasonic unit wear at least one pair of surgical rubber gloves and for extra prevention wear double pairs of gloves to isolate operator from infection or cross contamination of other patients It is recommended that eye and face protection be used during the use of this unit to prevent saliva spray from being inhaled and from entering the operators eyes Operator should be careful not to puncture the skin with any insert or tip containing saliva from patients 2 o nw m l
9. rt into open end of the handpiece and with a gentle press and turn motion the insert should snap fully into place Do Not Force Insert sani Vill Ix Scaling handpiece O ring moisten Scaling insert with H2o0 when inserting While holding handpiece upright press foot switch and water should Begin to exit the insert Allow the air to escape for about 10 20 seconds Turn power to medium position and the insert should vibrate with a strong mist Turn water knob to right if there is no mist or weak misting The inserts may give a drip and mist combination this is normal and actually preferred by most periodontal professionals The application of the power knob is for controlling the output power to the insert tip The operator can select the exact power needed for cleaning set the power to low medium for cooler handpiece insert temperature Note if your insert will not vibrate the problem could be with your insert Before requesting service try another insert The high power setting is for applications where excessive amount of calculus is built up The power setting can be used for periodontal sub gingival curettage and root planning procedures Most scaling should be done on the low to medium power settings Note DO NOT use excessive pressure with your scaler use gentle rapid motion with small overlapping strokes being certain that the scaler tip remains at a 15 degree angle to the tooth surface Unit is now read
10. switch is in the Off O position The water control knob should be in the high position Note it is normal for the knob to turn past the high position several rotations which will increase water flow substantially Set the power knob all the way to the left in the low position Plug the male water quick connect into the water source IE J452D4 Portable water tank J452D19 Faucet Connector J452D14 Saddle valve with female quick connect for inline water supply Note it is recommended that a line filtration device J452D13 be used to remove larger particles before entering the scaler Plug Power cord into the wall press toggle switch to the ON I position Hold the handpiece in a vertical upright position and step on the foot switch Within 10 15 seconds water should come out of open end of the handpiece If no water turn water control knob clockwise to get water flow and or check waterline connections Note inserts and handpiece will burn out in 45 60 seconds in the absence of water Never touch the vibrating end of the insert tip to any flesh such as cheek tongue or gums as this will cause a friction burn to the patient The tip should touch primarily the calculus on the tooth surface and NOT the enamel of the tooth Important to always keep the insert in motion to avoid heat buildup on the tooth Select insert Moisten rubber O Ring before inserting into handpiece While holding the handpiece upright place inse
11. y for use Shut Down Procedure L Turn water supply off either by releasing pressure from portable water tank J452D4 or by disconnecting quick water connector from water source Remember to turn water back on with the next use T Press toggle switch to the off O position LED light should be off Installation and operation of micromotor polisher I f you have a scaler only skip this part I The power selector switch should be centered to the OFF position Il Place the plug from the micromotor handpiece into the socket located on the right rear side of the console Slip a U style snap on prophy angle J1180D3 onto the steel connector of the micromotor handpiece This is done by aligning the slot on the prophy angle with the pin on the micromotor and applying downward pressure to the prophy angle thus sliding together applying straight pressure is all that is needed DO NOT TWIST while connecting If prophy will not fit ensure it is a U style prophy angle Only U style prophy angles will work with this unit Disposable prophy angles E style prophy angles will not work with this unit and may void warranty if used Alignment Pin Slot on prophy angle II Attach the snap on polishing cup to the prophy angle head cap Move the power selector switch downward to the polisher position the green indicator lamp should be illuminated IV Rotate the speed control knob to the left LOW SPEED until it stops Now