1. period is also influenced by temperature so in case there is a drop of temperature in order to preserve enzyme integrity the pump will start again for a new cycle This parameter indicates whether the pump is ON or OFF during boil In the case of selecting an external sensor the choice is always disabled This parameter controls the maximum working pump temperature In the selectable range it is equivalent to the Boiling temperature parameter set In the case of selecting an external sensor the choice is always disabled UP parameter increase DOWN parameter decrease START ENTER Confirm selection UP DOWN Exit from System Parameter menu 5 18 1 3 Automation Process Setting Through this menu it s possible to configure all the relevant parameters for the automatic mashing process O WN E QUT The basic principle of this configuration menu is the step mashing process For each step the user can configure target temperature SetPoint as well as step duration Moreover it s always possible to skip some of the steps according to the recipe schedule through the START button Some steps are mandatory Mash In A Amylase 2 Mash Out in order to guarantee the correct mashing work flow The system performs some integrity checks and tries to avoid user mistakes during configuration if some input values are not logical e g a step with lower SetPoint than the previous one the step is au
2. Hop additions This parameter indicates how many hop additions are foreseen during the boil phase Up to 10 are allowed Boil Duration 1 180min This parameter sets the total boil time required and starts timing only after boiling temperature is reached Hop x 0 180min This parameter set the time that the hops will remain on the boil The setting it must to be done from the first hops to the last entered This operation must be repeated for all hops expected Example for the management of hops If you do a boil for 60 minutes and you want to have 4 hops in boiling for 5 10 15 50 minutes you have to set Num of Hops 4 Boil time 60 Hop 1 50 Hop 2 15 Hop 3 10 Hop 4 5 The counting time is a countdown and time indicated for the hops indicates exactly how much remains in boil UP parameter increase DOWN parameter decrease START Next Step ENTER Confirm selection UP DOWN _Exit from Automatic Process Setting Menu 7 18 1 4 Recipe Management and Saving M A I A Ur IHIN START ENTER Ur IHIN START ENTER TT R r QUTI R r In this section it s possible to save up to 10 different settings inside the controller s memory for future use The stored information is related to mashing steps and hop additions a progressive number is assigned to the parameter sets according to first free memory position It s possible to load store and delete the settings whenever required Notice that a EEPROM initialization process ac
3. R J QUTI The automatic process Automation is the real core of the system and the controller executes in sequence all the steps TT previously configured in the Automatic Process Settings menu 3 1 Delayed Start It s also possible to program the brew day through a delayed start so the user can fill the vessel with water and decide to postpone the initial heating phase M QUT A M A R F R J The controller asks if the user wants to postpone the start and if Yes the amount of delay required in minutes should be GUTT entered In the case of the immediate start being selected the controller s normal sequence will be started 12 18 3 2 Recovery of previous brew session If a previous run has for some reason been aborted the system will asks the user if he wants to recover the previous process In an affirmative case the system will restart exactly from the step where the process had been aborted otherwise the system will start from the first mashing step M A I A UI IXNN START ENTER UF IMNN START EN TEE OTT R F HUTI R I 3 3 Water addition The first step is Mash In and the system asks explicitly if the proper amount of water has been added into the vessel M A I A Ur IHIN START ENTER Ur IHIN START LATER TT R I OTIT R r A positive answer to this question allows the process to continue otherwise the user is returned to the initial menu In order to allow
4. T ENTER Ur IHIN START ENTER TT R r OTIT R r 17 18 It s also possible to put the automatic mode in PAUSE by holding down the START button for a few seconds w vn e sy TT ATT R l To resume automatic operation you press and hold down the START button again At the end of the entire process the system defaults back to its initial settings w vn eo TE QUT GUTT R r During the process the push buttons will be used for the following operations UP Parameter Increase DOWN Parameter decrease START Step confirmation START PAUSE START long press ENTER Selection confirmation Step Skip long press UP DOWN Exit Automatic Menu 18 18
5. TART ENTER Ur IMF WN START ENTIER TT R r QUTI R r While waiting for the confirmation the heating element is continuously controlled by the PID algorithm so the temperature stays stable Once the user confirms to proceed the system enters another loop phase in order to allow the grain to be loaded into the malt pipe M A I A Ur IMF WN START ENTER Ur IMF WN START ENTER TT R l QUTI R r The pump is stopped while the temperature is maintained constant The system then asks if the grain has been loaded into the malt pipe After confirming that the malt loading is complete the system goes to the next step From this point on no manual intervention is needed and the controller will execute the complete work flow step by step 15 18 automatically maintaining the mashing temperature for the configured time duration The pump cycle will also be controlled accordingly during this period One note related to the pump rest In some cases a programmed rest will be skipped or last more than the configured value This is due to the programming logic where the pump starts working at the set point for the specific step and enters its rest time accordingly to the value set in its initial setting menu however this rest time is also linked to the heating process If the temperature drops below a configurable threshold both the heating element and the pump will be started again M A M A R F R J An alarm buzzer sounds and an in
6. User Manual Version 2 6 62 The objective of the project described in this manual is the mashing schedule and process automation for all grain beer production with a single vessel BIAB RIMS system Open Ardbir is largely inspired by the original project formerly Braudino by Stephen Mathison and then further upgraded and modified by Mike Wilson under the Mike s Brewery appellation The micro controller Arduino Uno is like in the original project at the core of the automation process and can be used in both a fully automatic or manual mode The controller automates all the phases from mashing in the grain to boiling the wort this includes any required hop additions The controller delivers all these capabilities in a simple easy to follow and logical manner for beginner and advanced home brewers alike The system interacts and can be programmed via 4 Push Buttons and an LCD feeds back all the relevant information the user needs in all the phases whether used while setting or running the system The Original Braudino shield was developed in order to connect a Temperature Probe SSR relay for controlling a heating element Pump Relay Signal Buzzer along with the LCD display and 4 Push Buttons This original shield is what has been referred to above as having been modified and upgraded by Mike Wilson From a HW perspective the code should be adapted in order to support the correct LCD display 16x2 or 20x4 This op
7. cessed through the dedicated menu below Is required before using the controller for the first time M A I A Ur IMF WN START ENTER Ur IMF WN START ENTER TT R r QUTI R r Once the EPPROM initialization has been performed it s possible to start saving the settings operations M A I A Ur IHIN START ENTER Ur IMF WN START ENTER TT R r MTT R r 8 18 The user can enter a name in order to identify the specific recipe using alphanumeric string with max 10 chars a z 0 9 w vn oe mw vn QUT QUTI space With the UP DOWN push button it s possible to scroll through the char list and ENTER is used for selection It s possible to correct the name of the recipe while entering characters press the START button This will allow us to move back one position and make the change By repeatedly pressing the START button you can return to the initial character It also provided a shortcut to facilitate the placing of the missing spaces to complete the name by simultaneously pressing the UP DOWN At the end the full name composed must be confirmed using the START button w vn oe wm vn QUT QUIT In order to load or delete a specific recipe the ENTER push button is used for selection while the confirmation is done through the START push button 9 18 Below are the details of a recipe loading screenshot TT And a recipe deletion screenshot QUIT R y a R T UP Parameter Increase DOWN Paramet
8. dication of the pump status is reported on the LCD display when the rest period starts QUT HUTI For each step a countdown timer is started when temperature reaches its set point A beep will sound to advise the user 5 seconds before the step ends Before the Mash Out step the process will stop with a prompt in order for the user to check for full starch conversion w wn van ENTER D d R F R J QUTI This next step is called the Iodine Test and the temperature settings are maintained the same as the previous QUT step The phase will be completed by pressing START 16 18 Once the mash out has been completed the pump is stopped and the system waits until the user confirms the malt pipe removal operation is complete M A M A Ur IHIN START ENTER Ur IMF WN START ENTER TT R r QUTI R r Once confirmed to continue the process the system notifies the user to remove the malt pipe If the user confirms the system enters the boiling phase In this final phase the system will provide sound and visual LCD indications of hop addition requests No explicit confirmation is needed in this case M A M A Ur IHIN START ENTER Ur IHIN START ENTER TT R r QUTI R r During all steps after Mash IN it s possible to skip one step and force the system to go to the next one This can be done by long pressing the ENTER button A confirmation is always requested in order to avoid mistakes M A M A Ur IMF WN STAR
9. er decrease START Confirm Operation Loading Saving Deleting Recipe Name ENTER Selection Confirmation UP DOWN _ Exit from recipe automation menu 10 18 2 0 Manual Process w vn oe mm vn QUTI UT The Manual Process allows the user the full control of the entire mashing process by allowing the manual selection of temperature settings and the switching ON OFF of both pump and the heating element at will Temperature control will be performed automatically through the PID control that will try to reach the manual set point The LCD display will report the manual SetPoint temperature and current temperature An automatic timer is started when the measured temperature reaches the set point Any set point change will reset the timer if the set point temperature is 2 C greater than measured temperature The 2 C hysteresis has been added in order to avoid the timer resetting due to small temperature changes During the boil phase that starts when temperature reaches the values configured in the system settings menu only the current temperature is reported on the LCD and it s possible to regulate the heating element power with UP DOWN button the of power used is shown on the LCD w vn eo Mw eh nm QUTI QUTI R r UP Temperature Power Increase DOWN Temperature Power Decrease START Heating Element ON OFF ENTER Pump ON OFF UP DOWN _ Exit from Manual Process 11 18 3 0 Automatic Process M A M A R F E
10. ough this menu the relevant constant that influences the PID controlling algorithm and so the heating element control is set It is also possible to configure output power of the heating element during the boil phase and temperature probe calibration The details Constant P 100 100 Proportional part of the PID control algorithm Constant I 100 100 Integral part of the PID control algorithm Constant D 100 100 Derivative part of the PID control algorithm Window ms 1000 7500 PID control time window in millisecond PWM 0 100 Heating power percentage applied to heating element during boil Calibration 5 00 5 00 Temperature probe offset calibration 0 10 step UP parameter increase DOWN parameter decrease START ENTER Confirm selection UP DOWN _ Exit from PID menu Note that fine tuning of the PID parameter is out of the scope of this user manual and many factors related to the brewing system can influence the optimal setting For a more detailed explanation of PID control algorithm please refer to Wikipedia http en wikipedia org wiki PID_controller A simple method to get an easy calibration of the PID algorithm suggests to set to 0 the value Ki and Kd and try to fine tune only the Kp that allows the PID to get as close as possible to set point trying to minimize the difference between actual temperature and set point Subsequently it is possible to tune the kI and kD considering that e Incase the measured tem
11. perature overshot the set point reduce Kp and Increase kD e Incase to much time is needed to get the controller to the set point increase kI e Incase of a permanent error below the set point increase kI 4 18 TT 1 2 Unit Parameters OUN Through this section the user can configure the overall system parameters and global variables that will affect the end to end system behavior Typically this set up is specific for the brewery and should be performed once There are dependencies in some of the choices and so not all reported values are allowed some consistency and validation rules are applied automatically Temperature Unit C F Sensor Internal External Boiling 90 105 C 194 221 F Pump Cycle 5 15 minutes Pump Rest 1 5 minutes During Boil ON OFF Pump Stop 80 105 C 176 221 F It s possible to select either Celsius of Fahrenheit This parameter should be set according to the sensor s physical placement Internal means that the temperature probe is inside the Vessel while External means that the sensor is external in the recirculation circuit near the pump This choice will influence pump behavior This parameter sets the boiling point It is automatically set in both measurement units This parameter sets the pump cycle duration once the temperature has been reached during the automatic mashing cycle This parameter sets the rest pump time between one cycle and another This rest
12. proper wort recirculation the pump is initialized and primed with a few short ON OFF cycles M A A Ur IMF WN START ENTER Ur IMF WN START ENTER GUTT R I MET R r 13 18 This operation is useful to expel air bubbles from around pump circuits and impellers At the end of this phase the pump is started and the water recirculated After this operation the automatic process starts operating and the heating element is switched on in order to heat the water up to the set strike temperature In the case of a delayed start having been programmed the user is requested to enter the value of the delay in minutes M A M A Ur IHIN START ENTER Ur IHIN START LATER TT R I MET R r Once the delay has been programmed and confirmed the system enters into a standby mode M A M A Ur IHIN START ENTER Ur IHIN START LATER TT R r OTIT R r A countdown will be displayed on the LCD M A M A Ur IMF WN START ENTER Ur IHIN START ENTER TT R I MET R r At the end of the standby period an alarm sounds and notifies the user that the process has started and the heating element is switched ON From this point on all the operations follow the same common processes regardless of the initial choice 14 18 M A A Ur IMF WN START ENTER Ur IMF WN START ENTER MTT R I QUTI R r The system starts heating and recirculating the water and when the strike temperature is reached the system enters into a paused loop status M A A Ur IHIN S
13. rectly manage recipe storing Please read the proper section for the right parameter configuration Let s see the step by step configuration taken through the push button and display menus 1 18 0 0 Startup Display M A M A r R I This is the boot screen of ArdBir In order to enter a desired menu the user should push the selected button for at least TT R QUT two seconds At the end of both the MAUNAL and AUTOMATIC process the user is always returned back to this initial menu The same also applies whenever the user exits from the CONFIGURATION menu UP DOWN MANUAL program START AUTOMATIC program ENTER SYSTEM CONFIGURATION 2 18 1 0 System Configuration M A R I TT TT M A R I A user can access the set up menu by pressing the ENTER push button for 2 seconds This menu allows the user to set up all the basic parameters and configurations that decide the final behavior of the brewing system The set up menu allows the user to access e PID parameters e Unit parameters e Process Automation Set Up e Recipe Management e Credits By selecting the UP and DOWN push buttons the user can scroll through menus and a selection can be confirmed by pressing ENTER UP Sub menu scrolling DOWN Sub menu scrolling START Exits from CONFIGURATION menu ENTER Confirm Selection 3 18 1 1 P I D parameters OUT HUTI The first menu section is related to PID parameter tuning Thr
14. tion is configurable inside the sketch In order to enable one or the other display the user should modify the sketch through the Arduino IDE searching for Ctrl f LCD as the search string and then apply the modifications below in both sections SETTING LCD Select your LCD LANGUAGE ITA include LCD16x2_ITA h include LCD20x4_ITA h LANGUAGE ENG include LCD16x2_ENG h include LCD20x4_ENG h SETTING LCD lcd begin 16 2 Icd begin 20 4 User should remove before the include and Icd begin statement for the correct size LCD and add before the incorrect size LCD Moreover it s possible to select Italian or English language in the same way modifying the first LCD section The same procedure should be repeated in order to select the HW version of the controller Shield The proper section for this type of settings is the following SETTING PCB Select your PCB Version include Pcb_Brauduino_DanielXan h include Pcb_Brauduino_Original h Finally some mandatory additional libraries are needed in order to properly compile the sketch These libraries can be easily downloaded from the Arduino official site http arduino cc Onewire http playground arduino cc Learning OneWire PID_vi1 http playground arduino cc Code PIDLibrar WARNING First step to be performed in order to guarantee the right system operation is the system configuration and reset of EEPROM in order to cor
15. tomatically skipped The only exception is the first step after Mash In where the temperature can be set up to 3 5 C lower Here is the full steps list PHASE Mash In Phytase Glucanase Protease B Amylase A Amylase 1 A Amylase 2 Mash Out TEMPERATURE 20 75 C 68 167 F 25 55 C 77 131 F 35 50 C 95 122 F 45 60 C 113 140 F 50 70 C 122 158 F 60 76 C 140 168 75 F 60 76 C 140 168 75 F 75 80 C 167 176 F DURATION 1 140min 1 140min 1 140min 1 140min 1 140min 1 140min 1 140min DESCRIPTION The strike temperature for the Mash In start phase should be entered No duration is foreseen since unless the grains are added and confirmed the temperature is maintained constant This step can t be skipped First step both temperature and duration should be entered It s possible to skip the step by pressing the START button during the temperature setting Second step configurable as above It s possible to skip by pressing START Third step configurable as above It s possible to skip by pressing START Fourth step configurable as above It s possible to skip by pressing START Fifth step configurable as above It s possible to skip by pressing START Fifth step configurable as above This step is mandatory Sixth step completely configurable Mash out is mandatory step 6 18 PHASE DURATION DESCRIPTION N

Download Pdf Manuals

image

Related Search

Related Contents

Passenger and Light Truck Replacement Tire Limited Warranty  NELLCOR N-3900 Patient Monitor Service Manual  Manual de Instruções (PDF:2809KB)  Lista de chequeo para la revisión de andamios móviles    baas ma me - Schneider Electric  User Manual  PICADORA DE HIELO  présentation des spectacles scolaires  MARSCHALS Level 2 Software User and Reference Manual  