User Manual, Anybus-Communicator Ethernet-USS

image

Contents

1. i e Siemens USS Gateway Mozilla Firefox JE Destination address Ele Edt vew History Bookmarks Tools Heb y Gs LJ http 10 10 20 240 httpd Profinet Emz y gt Gl p gt Getting Started Q Latest Headlines Sender Hrs USS Master Configuration 11 Address of the sender Setup E Mail Notification functions ba Subject Email Address lt receive host domain gt Subject for the message aan e Message Actual message body Email Notification Setup Optionally additional keywords can be in ae MAN eee Caen P 2 a 10 18 26 d cluded in the message as follows 7 Ca Go E Se Keyword Action E 3 Se E TT TT k g io w o milo lt Slave gt Includes the number of the slave A ee ee ee lt Status gt Includes the status of the slave e Email Notification Setup Specifies which slaves that shall trigger email status notifications to enable notification for a par ticular slave check the corresponding checkbox To disable notification for a slave uncheck the checkbox Click Store to save any changes Example Recipient cliff barnes com Sender bobby ewing com Subject Oops Message Slave no lt Slave gt has changed status to lt Status gt Note This features requires a valid SMTP server account The SMTP account settings can be accessed via the built in web serve
2. Green Initialized Green 1 flash Diagnostic data available Green 2 flashes Blink Used by engineering tools for identification Red 1 flash Configuration Error I O Size or Configuration Mismatch Red 3 flashes No Station Name or invalid TCP IP configuration Red 4 flashes 3 Link Activity Off Internal error Ethernet link established Green Transmitting receiving data on ethernet interface Green flashing 4 not used Ethernet link not established 5 Gateway Status Off no power Red short period Red flashing 1Hz Accessing new configuration No configuration present Red flashing 2Hz Configuration error Red flashing 4Hz Green Initialization error Operational Green flashing 1Hz Green flashing 4Hz 6 USS Status Off Configuration in progress Initialization in progress Idle or no power Green Green flickering Red Communication detected Transmitting data Communication timeout Chapter 2 Data Exchange Overview The mapping of USS data to PROFINET is based on the mapping scheme defined by the PNO working group for PROFINET IO Proxy Devices In short this means that on PROFINET each USS slave is represented through a dedicated slot Slot 0 is reserved for the gateway itself while slot 1 31 is as sociated with the slaves on the USS network Each slot uses one subslot for the mapping of its
3. 35 17 29 09 Online www anybus com HMS America E mail us suppott hms networks com Phone 1 773 404 2271 Toll Free 888 8 Anybus Pax 1 773 404 1797 Online www anybus com HMS Germany E mail ge suppott hms networks com Phone 49 721 96472 0 Pax 49 721 964 7210 Online www anybus com HMS Japan E mail jp support hms networks com Phone 81 45 478 5340 Fax 81 45 476 0315 Online www anybus com Introduction General Information Chapter 1 The Anybus Communicator Ethernet USS Gateway functions as a gateway between the Universal Serial Interface Protocol from now on referred to as USS and PROFINET IO Acting as a slave with Real Time capabilities on the PROFINET side and as a master on the USS network it controls up to 31 USS slaves The gateway can be configured solely via the PROFINET configuration tool i e no proprietary config uration utilities are required The built in web server allows monitoration of data through an easy to use web based user interface Additionally a built in email client can issue email messages as the status of the slaves on the USS net work changes Features USS Anybus Communicator CI E e PROFINET IO slave Real Time operation e USS master controls up to 31 USS slaves e Up to 16 words of Process Data PZD per slave e Up to 4 words of Parameter Data PKW per slave e Configuration via PROFINET e Web based monitoration of data e Statu
4. A A NAO 3 4 SD Ie Ser Up Gig Add the Gateway tothe COn onrat OM raini AA 3 4 SIDA DECI INC BAME OR UET S S INANON a A A AAA 3 5 Step 3 Add Data from the USS Network to the Configuration a a 3 6 E DOW UD E COMM ATION AAA AE E A 3 6 Chapter 4 Appendix A Appendix B Appendix C Web Interface Genri TAO ao easy nent earn eR Eo RE INSTT oR SE PATE E EAE 4 1 Ms raton AS ta E E E E E T 4 2 Exa LE AS AN E ute caus asa teesisas 4 2 ER A A NO 4 2 VAIS COREA NS TUTE cic EEEE EE T EEE AE T ava omnactie 4 3 E CIAT A SAN 4 3 VALE IN OD GAO DO ans 4 4 Save ATO SNCS ca se E alo da batsk aaa ats dausastatosieisidaastes 4 5 SLE LOO OCC NTE eT OCR Ra E EUR eCER Te oer sR nr emer TT 4 5 E IT air xed TEE 4 5 SUC NAS PEETA A ic 4 6 PPro s AD O AA waa NAARAAT 4 6 Anybus IPconfig HICP o A O A 1 A A O A 1 Connector Pin Assignments PROF INE Trac RA AA AAA AAA B 1 Pon r COn Ko eee does os cladatas B 1 US ida B 1 Technical Specification Mechanical Properties oi C 1 Te NEC al CAPAC TO EIS O ON Ci Piviromimental Cacen eena a eo a Gel Resulaton Compliance calorias C 2 Preface About This Document How To Use This Document This document contains a general introduction as well as a description of the technical features pro vided by the Anybus Communicator PROFINET USS Gateway The reader of this document is expected to be familiar with USS and PROFINET network technology as well as communication systems in general The reader i
5. products The network can be rescanned at any time by clicking Scan In the list of detected devices the gateway will by default appear as ABC PR T USS ES To alter the network settings of the gateway double Ethernet configuration A IP address wo w 2 DHCP click on its entry in the list A window will appear C On wo i Subnetmask 255 255 255 0 ie containing the actual IP settings Default gateway oO 0 oO 0 Validate any changes by clicking Set or click Cancel to cancel Primary DNS oO oO 0 0 Secondary DNS i BM o 8 0 Optionally the configuration can be protected from unauthorized access by a password To enter a pass word click on the Change password checkbox and enter the password under New password See also e 3 1 TCP IP Settings e 4 2 IP Address Settings Appendix B Connector Pin Assignments PROFINET Interface RJ45 Pin Signal Notes 1 TD 2 TD 3 RD 4 Normally left unused to ensure signal integrity these pins are tied 5 together and terminated to PE via a filter circuit 1 8 6 RD 7 Normally left unused to ensure signal integrity these pins are tied 8 together and terminated to PE via a filter circuit Power Connector Pin Signal Notes 1 24VDC 2 GND Notes e Use good quality 60 75 or 75XC copper CU wire only e Terminal tightening torq
6. BUS PA EH PROFINET I0 H Q Additional Field Devices EH Gateway 2 1 Anybus C a ABC USS PRT J Other modules USS_Configura E Gateway C General E 120 E SIMATIC 300 ca E SIMATIC 400 E SIMATIC PC Based Control 300 40 a 1 ABC USS PRT f SIMATIC PC Station Slot a Module l Order Number lAddress Q address Diagnostic address Comment a ABOUSE SET O JAUSS ART ETER o co juju nybus C USS PROFInet GSDML 1 0 Hms ABC USS PRT x 10 Press F1 to get Help Chg 3 Select the Parameter tab C 4 Specify the baudrate for the USS network D gt Properties ABC USS PRT E xj Addresses Paramete O 3 Parameter EH Parameter El Baudrate 38400 kbits Afp 9600 kbits 19200 kbits 5 Click OK when done E Network Configuration 3 6 Step 3 Add Data from the USS Network to the Configuration Each slave on the USS network is represented trough a dedicated slot The slot number correlates 1 1 to the USS slave number i e slot 23 on PROFINET represents USS slave 23 To add data from the USS network to the configuration perform the following steps 1 Right click on a slot corresponding to the USS slave for which data shall be added Select the Insert Object entry Insert Object Add Master System Disconnect Master System Select an object which matche
7. Config SIMATIC 300 Station Configuration 57_Pro3 E 8 xj Edit Catalog Profile Dl Station Edit Insert PLC view Options Window Help l x polele 6 eje dji 5 28 re Update Catalog Install Hw Updates Install GSD File RE PROFIBUS PA 5 PROFINET I0 Additional Field Devices EU Gateway Find in Service amp Support EU Anybus C ga ABC USS PRT J Other modules J USS_Configura H E Gateway H General RM simaric 300 mp 1 ABC USS PRT SIMATIC PC Station Slot J Module Ord Address Q address Diagnostic address Comment a la ARCUSSART ARCUESART 8188 a Ll ABC USS PRT HMS Industrial Networks 17 Anybus C USS PROFInet En GSDML41 OHms ABC USS PRT y Press F1 to get Help Chg Network Configuration 3 5 Step 2 Specify the Baudrate for the USS Network To specify the baudrate for the USS communication perform the following steps 1 Highlight the gateway in the network configuration HW Config window A 2 Right click on slot 0 B and select Object Properties HW Config SIMATIC 300 Station Configuration 57_Pro3 E ll xj hy Station Edit Insert PLC Yiew Options Window Help 18 xj Dj2 5 8 8 Sl solo ED E 2 ne al xj Find nt mil Profile Standard Dd E PROFIBUS DP 82 PROFI
8. User Manual Anybus Communicator PROFINET USS Gateway Rev 1 01 HMS Industrial Networks AB a lt Germany 49 721 96472 0 ge sales hms networks com y y Japan 81 45 478 5340 jp sales hms networks com Sweden 46 35 17 2920 sales hms networks com FITTTIS U S A 1 773 404 3486 us sales hms networks com f y Table of Contents Table of Contents Preface About This Document HowTo Use Ls DOCENA a P 1 portant User Miro rman A AAA AAA AAA P 1 We ated DOCCT did O P 2 Document Esto dido P 2 CON entons S eno O orion P 3 SU pocos O A E SE E T TE A P 3 Chapter 1 Introduction General Mormon ds E au meena tele itett 1 1 E KRE E eases co E T EE E EE E E TE E E E E E E EE cade 1 1 O O 1 2 aS A LO 1 3 Chapter 2 Data Exchange OIE A AAA AAA AA do 2 1 SS Masterpiece doin 2 2 GORRA LONA RAE AA AA AA AS 2 2 COUT UI AA E sis oe ecient vests O TENO S ad eaten 2 2 ODE IENE E oli 2 2 SIA VS VATA SO O NO 2 3 CONT al TUOU OU ois Sees Seat A A RS 2 3 AUS LATS TROT CT iat oneal aoe lo so dades 2 3 GCOS ATE TID EET E A TS EN 2 3 PATRIO A Seo Baan aco A A aaa Masse 2 3 Chapter 3 Network Configuration General Into rid OM A A II 3 1 TER dt a ld dd 3 1 OTA Ld Bl Eden Col of 01 nn oi ici 3 1 ACO IN ATS a 3 2 GAMA OU sneered teas bes Baad oes st tts dette tad iaa 3 2 SINEAVTE PIII CTU TOOL AAA AAN A Ad dd 3 2 SLATI Manager E a EIN INA cl idad 3 3 USS X PROFINET Contiouration SIMATIC Manso it ias 3 4 COMTI I OVI AIO REA
9. ages Note Administration See also 4 2 Administration Pages Slave Diagnostics See also 4 5 Slave Diagnostics User defined pages Expert Users Only Optionally advanced users may create custom web pages Contact HMS for further information Certain features requires a JAVA capable browser Administration Pages General Information Web Interface 4 2 The main administration page features the following sub pages e IP address settings See also 4 2 IP Address Settings e Master Communication Settings See also 4 3 Master Communication Settings e Master Configuration See also 4 3 Master Configuration e E Mail Notification Settings See also 4 4 E Mail Notification Settings IP Address Settings Y Siemens USS Gateway Mozilla Firefox File Edit View History Bookmarks Tools Help SY mi gt 7 1 O http 10 10 20 240 httpd SIMOadmir y gt Gl Pe Getting Started D Latest Headlines mins USS Master Communication 11 Anybus S Profinet IO IP address settings USS Master communication parameter USS Master Configuration Setup E Mail Notification functions This page provides access to basic network settings 1 e IP address subnet mask etc By default the gateway retrieves these settings from a DHCP server If using manually specified settings make sure to uncheck th
10. assigned data to PROFINET In addition to the Process Data PZD and Parameter Data PKW the Slave Data Set also features a Slave Status Register which reflects the overall status of the slave Note that all data is exchanged transparently This means that in order to be able to access Parameter Data PKW the parameter access protocol used to access PKW data must be implemented entirely on the PLC side USS Slaves Anybus Communicator Gateway IO Controller Save 1 PKW Slave 1 PKW Slave 1 PZD Slave 1 PZD Slave 1 Status Register reserved set to zero Slave 1 PKW Slave 1 PKW Slave 2 Status Register Slave 1 PZD Slave 1 PZD Slave 2 PKW Save 2 PKW e Save 2P2D Slave 3 PKW FRO INET Interface reserved zero Slave 3 PZD Slave 1 PKW Slave 3 Status Register reserved set to zero Slave 1 PZD Slave 3 PKW Slave 3 PKW Slave 3 PZD Slave 3 PZD reserved zero Slave 2 PKW o Slave 2 PZD e Slave N PKW reserved zero Slave N Status Register reserved set to zero Slave N PKW Slave N PKW Slave N PKW Slave N PZD Slave N PZD Slave N PZD Slave N PZD See also e 2 2 USS Master Implementation e 2 3 Slave Data Set e 3 4 USS amp PROFINET Configuration SIMATIC Manager e 4 1 Web Interface 4 3 Master Configuration Data Exchange 2 2 USS Master Implementation General Information The USS protocol Universal Serial Interface Protocol defines an access technique accordi
11. ay name Profinet Gateway for Siemens Drives with USS Protocol a Gateway Version 1 02 Fieldbus interface firmware revision AnyBus Type 132 ProfiNet 1 0 Module AnyBus Version 2 02 Gateway Status Operational USS Master Status Running e Gateway Status Profinet Interface Operational Overall gateway status e USS Master Status Status of USS master e PROFINET Interface Fieldbus interface status Web Interface 4 6 Slave Status This page shows status information for each slave device on the USS network e Dev 3 Y Siemens USS Gateway Mozilla Firefox Jog D evice addres S File Edit View History Bookmarks Tools Help a y GS http 10 10 20 240 httpd Profinet uss gt Gl p gt Getting Started Q Latest Headlines rational o Ope j Hims USS Master Communication A 11 las Device status e g Operational Non Opera tional Not Present etc USS Slave Status Dev Operational PKW Size PZD Size A 1 Not Present Gi 2 e PKW Size OO ATI ET 3 Not Configured ESO 4 Not Configured Size in words of Parameter Data PKW as E o 6 notconfigures o __ ___ sociated with the slave device pies a i om A aT e PZD Size TREPA 13 Not Configured 14 Not Configured Size in words of Process Data PZD associ Sa gt 2 ae not Configwed_ _ z E 17 ___ Not Configu
12. bits fixed to 1 e Parity fixed to even Master Configuration Y Siemens USS Gateway Mozilla Firefox Jay File Edit View History Bookmarks Tools Help Gt E http 10 10 20 240 httpd Profinetjuss y gt G gt Getting Started D Latest Headlines ii i ams USS Master Communication dl USS Master communication parameter Baudrate 38400 Data bits 8 Start bits 1 Stop bits 1 Parity Even This page presents an overview of the communication with the slaves on the USS network The leftmost column contains the USS device address followed by the data sizes specified in words for that device The remaining columns reflects how the data is mapped internally in the gateway Y Siemens USS Gateway Mozilla Firefox Jak File Edit View History Bookmarks Tools Help a gt E f C http 10 10 20 240 httpd Profinet uss G gt Getting Started Ey Latest Headlines HS USS Master Communication 1 Anybus S Profinet IO USS Master Configuration Web Interface 4 4 E Mail Notification Settings The gateway continuously monitors the status of OP USSF and FNF in the Slave Status Registers Op tionally an email notification can be issued when the status of a slave changes e Recipient
13. ct contains ESD Electrostatic Discharge sensitive parts that may be damaged if ESD control procedures are not followed Static control precautions are required when handling the product Failure to observe this may cause damage to the product Related Documents Document About This Document P 2 Author Document History Summary of Recent Changes 1 00 1 01 Change Page s Removed redundant section Gateway Status Register Misc minor corrections and adjustments Revision List Revision 1 00 1 01 Date Author 2006 09 05 PeP 2007 08 27 PeP Chapter s Description All Initial revision Misc minor corrections About This Document P 3 Conventions amp Terminology The following terms and conventions are used throughout this document Numbered lists provide sequential steps Bulleted lists provide information not procedural steps The terms gateway and ABC refers to the Anybus Communicator gateway The term USS refers to the Universal Serial Interface networking system PRT refers to the PROFINET networking system Slave Data Set refers to all data associated with a slave Hexadecimal values are written in the format Ox NNNN where NNNN is the hexadecimal value Support HMS Sweden Head Office E mail support hms networks com Phone 46 0 35 17 29 20 Pax 46 0
14. dd the Gateway to the Configuration To configure the gateway perform the following steps Options 1 Open the SIMATIC Manager and start a new project praia allie Text Libraries gt 2 Select Set PG PC Interface entry in the Options menu Display Language Manage Multilingual Texts 3 Change the PG PC Interface to TCP IP Auto eTR Run Time Properties Reference Data gt Define Global Data Configure Network Access Path Access Point of the Application Simulate Modules SFONLINE STEP TCPIP uto D Link DFE 530 Standard for STEP 7 Configure Process Diagnostics Set PG PC Interface Interface Parameter Assignment Used TCP AP Auto gt D Link DFE 530T FCI F TCPYIP gt D Link DFE 530T PCI RS TCP IP gt Ndiswanlp Diagnostics EN TCPAP Auto gt D Link DFE 530T gt Copy HA TCPAP Suto gt D Link DFE 530TX gt Dele Assigning Parameters to Your NDIS CPs with TCP IP Protocol RFE 1006 Interfaces Add Remove Select 4 Highlight the station and double click on Hardware Options 5 Inthe HW Config window import the GSD file by selecting Customize Ctri Alt E the Install GSD file entry in the Options menu Specify Module Configure Network 6 Drag amp Drop the ABC USS PRT into the network silage ies e ia Report System Error E HW
15. ds to be assigned a Station Name This can either be done using the SIMATIC Manager or using the SIMATIC Primary Setup Tool Both cases are described in this document SIMATIC Primary Setup Tool Note The following example uses the SIMATIC Primary Setup Tool This tool is sometimes not in cluded in a typical Step 7 installation In such case it is also possible to use a built in function called Edit Ethernet node see 3 3 SIMATIC Manager Edit Ethernet Node To specify the Station Name using the Primary Setup Tool perform the following steps 1 Open the SIMATIC Primary Setup Tool 2 Select the Network Adapter entry in the Settings menu 3 Highlight the ethernet interface used for the gateway and select the Browse entry in the Net work menu 4 When prompted enter the station name e g ABC USS PRT Primary Setup Tool Sieme 15 Network Module Settings gt ala E Ethernet interface EY ABC USS PAT 00 30 11 02 45 F1 10 10 21 11 E S Ind Ethernet interface MAC address mi eh A A e fh S PC 08 00 06 6F DF F4 10 10 21 54 Obtain IP address from DHCP server Identified by MAC address f Device name Client ID O Assing IP narameters Station name JAB C LISS PRT cence 10 T Enable DHS Configure DHS See also e 3 3 SIMATIC Manager Edit Ethernet Node Network Configuration 3 3 SIMATIC Manager Edit Ethernet Node N
16. e DHCP ena bled checkbox See also e 3 1 TCP IP Settings Note Generally any changes made to the settings on this page requires a reset to have effect 8 Siemens USS Gateway Mozilla Firefox File Edit View History Bookmarks Tools Help fa E gh http 10 10 20 240 nttpd Profinetjue y B Glr gt Getting Started Latest Headlines Hms USS Master Communication 1 Anybus S Profinet IO General information Fieldbus configuration Device name Station type Vendor ID Firmware version 2 02 Boot loader version 1 14 Serial number A003AF70 MAC address 00 30 11 02 2F CB ABC USS PRT ABC USS PRT 268 SMTP user name SMTP password DECP enabled Device ID 5 Ethernet configuration IP address 10 10 20 240 Subnet mask 255 255 255 0 Gateway address 10 10 21 1 DNSi address 10 10 20 6 DNS2 address 10 10 12 12 Host name Domain name hms se SMTP server 0 0 0 0 STORE CONFIGURATION REBOOT GATEWAY Master Communication Settings Web Interface 4 3 This page presents the communication settings for the USS interface e Baudrate The following baudrates are supported 9600bps 19200bps 38400bps Note that the baudrate is specified in the PROFINET configuration tool see 3 5 Step 2 Specify the Baudrate for the USS Network e Data bits fixed to 8 e Start bits fixed to 1 e Stop
17. meter Data PKW size is device dependent Process Data PZD Process Data PZD Slave Status Register This register reflects the current status of the slave Isb Isb b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 bO RES FNF USSF OP RES CFG RES Slave No e RES Reserved Reserved for future use mask off and ignore e FNF Fieldbus Network Fault This bit indicates if the fieldbus has gone on set or off cleared line USSF USS Fault This bit is set if a USS master slave communication fault has been detected e OP Operational This bit is set if the gateway has detected the slave and found it operational CFG Configured This bit is set 1 if the node is configured in the master or cleared 0 if not configured e Slave No USS slave address 0 31 Process Data PZD This 1s the actual Process Data PZD image Parameter Data PKW The gateway does not process the Parameter Data PKW data in any way This means that the param eter access protocol used to access PKW data 1f required must be implemented entirely on the PLC side Exactly how this is done is beyond the scope of this document Chapter 3 Network Configuration General Information As mentioned previously the gateway can be configured solely via the PROFINET configuration tool e g Step 7 No local configuration utilities or settings are required The configura
18. ng Mode Ctrl 1 Clear Reset Set Time of Day To download the finished configuration to the IO Controller select Moritor Modfy the Download entry in the PLC menu Update Firmware Save Device Mame to Memory Card Ethernet gt PROFIBUS gt Saye Service Data Chapter 4 Web Interface General Information The gateway features a web based configuration and monitoration interface used to set up basic com munication properties 1 e IP address network mask etc as well as to monitor the status and data of the individual slaves on the USS network To access the web based configuration interface perform the following steps 1 Open a web browser e g Mozilla Firefox 2 Enter the IP address of the gateway in the address field The gateway will ask for authentication The username is USS Gateway and the password is 1234 Siemens USS Gateway Mozilla Firefox Ja E File Edit View History Bookmarks Tools Help a K 2 E http 10 10 20 240 httpd ndex htmi y gt G A gt Setting Started E Latest Headlines ii a i HIMS USS Master Communication 1 Administration Drive Service Drive Diagnotics Authentication Required User defined pages 9 Enter username and password for USS Ethernet Gateway at htto 10 10 20 242 Le User Mame Password Cone li Cancel The main page contains links to the following sub p
19. ng to the Master Slave principle for communication via a serial RS 485 based communication bus The protocol includes fixed or variable frame length cyclic acyclic and point to point communications The gateway communicates according to a subset of the protocol implementing support for cyclic communication with fixed frame lengths All PKW and PZD data is exchanged transparently This means that the parameter access protocol used to access PKW data if required must be implemented entirely on the PLC side Configuration The gateway can be configured solely using the PROFINET Configuration Tool e g Step 7 No local configuration tools or settings are required See also e 3 1 Network Configuration Operation The gateway will only poll slaves marked as Operational in the internal scanlist Each time a bus cycle is completed the gateway checks the status of slaves previously marked as Non Operational and up dates the scanlist for the next cycle as necessary The status of each individual USS slave can be read in its corresponding Slave Status Register See also e 2 3 Slave Status Register e 4 5 Slave Diagnostics 4 5 Slave Diagnostics Data Exchange 2 3 Slave Data Set General Information The data associated with each slave is organized as follows Data from Gateway Data from lO Controller Slave Status Register reserved set to zero 2 bytes Parameter Data PKW Para
20. ote The following example uses the SIMATIC Manager It is also possible to use the SIMATIC Pri mary Setup Tool see 3 2 SIMATIC Primary Setup Tool To specify the Station Name using the SIMATIC Manager perform the following steps 1 Open the SIMATIC Manager Select the Edit Ethernet Node entry in the PLC menu Select the gateway in the list of devices Browse Network and click OK Specify the Station Name in the Assign device name field When done click Close ye de a Edit Ethernet Mode Ethernet node MAC address 157 163 428 192 168 0 1 00 30 11 02 45 EB 08 00 06 66 93 3C ABC USS P 3 300 ABC USS PR PH I0 SetlP configuration C Use IP parameters IP address Subnet mask Obtain IP address from a DHCP ser Identified by f ClientlD MAC address Cancel Help Client ID Assign device name Device name ABC USS PRT Assign Name Reset to factory settings Reset Close Help See also e 3 2 SIMATIC Primary Setup Tool Network Configuration 3 4 USS amp PROFINET Configuration SIMATIC Manager General Information The purpose of this section is to illustrate how to add the gateway and data from the USS slaves to the PROFINET configuration Note that a prerequisite for the following examples is that all TCP IP set tings are properly configured Step 1 Set Up and A
21. r See also e 4 2 IP Address Settings Web Interface 4 5 Slave Diagnostics General The main diagnostic page features the following sub pages e Identification and Status Y Siemens USS Gateway Mozilla Firefox Qu See also f File Edit View History Bookmarks Tools Help 2 UN y GS L http 10 10 20 240 httpd DriveDiaa ht y gt G 4 5 I dentification and Status Getting Started EN Latest Headlines 41 mms USS Master Communication 11 e Slave Status Display identification and status See als O eg Visualisation A Drives 4 6 Slave Status e View Process Data of Operational Slaves See also 4 6 View Process Data of Operational Slaves Identification and Status This page displays information about the gateway as well as the general status of the USS network this information may be useful when contacting HMS support services e Gateway Name Profinet Gateway for Siemens Drives with USS Protocol e Gateway Version General gateway firmware revision Y Siemens USS Gateway Mozilla Firefox QuE File Edit View History Bookmarks Tools Help AN http 10 10 20 240 httpd SIMOstatus gt Gl e Anybus Type E Getting Started G Latest Headlines 11 Higher level network interface type ans USS Master Communication Anybus S Profinet IO A A ybus Version Identification and Status Gatew
22. red E 2 ated with the slave device udo 2 19 Not Configured l v Done View Process Data of Operational Slaves This page can be used to monitor the Process Data Y Siemens USS Gateway Mozilla Firefox Jog PZD of all operational slaves on the USS network File Edit View History Bookmarks Tools Help gt Gi Y http 10 10 20 240 httpd Profinetvis gt Gl All data 1s represented as an array of words in hexa decimal format DP Getting Started D4 Latest Headlines 11 ams USS Master Communication 11 las uni Visualisation of Process Data of operational Drives Select Device to view Process data lr ES E ER E ES GO E Gs Ge ss az Js ls JLo E Jas J 2 IL 2 129 Io 1831 Process Data Device 1 To USS 0x0000 0x0000 From USS 0x0000 0x0000 Select Device to view Process data OIE ES ES EA E O o As e Es as Caz Jlse Log C20 L2 Je JL L2e Jas L26 1827 JL2e l29 E30 Lz Process Data Device 2 To USS Not Configured AA From USS Not Configured i Applet ShowValue started Appendix A Anybus IPconfig HICP General The gateway supports the HICP protocol used by the Anybus IPconfig utility which can be downloaded free of charge from the HMS web site This utility may be used to access the TCP IP settings of any Anybus product connected to the network via UDP port 3250 Operation Upon starting the program the network is scanned for Anybus
23. s also expected to be familiar with the Mi crosoft Windows operating system Important User Information The data and illustrations found in this document are not binding We HMS Industrial Networks AB reserve the right to modify our products in line with our policy of continuous product development The information in this document is subject to change without notice and should not be considered as a com mitment by HMS Industrial Networks AB HMS Industrial Networks AB assumes no responsibility for any errors that may appear in this document There are many applications of this product Those responsible for the use of this device must ensure that all the necessary steps have been taken to verify that the application meets all performance and safe ty requirements including any applicable laws regulations codes and standards Anybus is a registered trademark of HMS Industrial Networks AB All other trademarks are the prop erty of their respective holders The examples and illustrations in this document are included solely for illustrative purposes Because of the many variables and requirements associated with any particular implementation HMS cannot as sume responsibility or liability for actual use based on these examples and illustrations Warning This is a class A product In a domestic environment this product may cause radio interfer ence in which case the user may be required to take adequate measures ESD Note This produ
24. s notifications via Email e DCP Discovery and Basic Configuration capable e DHCP capable e Supports Anybus IPconfig HICP IO Controller PLC PROFINET node PROFINET PROFINET node Z Remote Administration Introduction 1 2 External View See also B 1 Connector Pin Assignments A PROFINET Interface TA See also La ls QV ES B 1 PROFINET Interface RJ45 B Status LEDs See also 1 3 Status LEDs C Service Port reserved D USS Interface See also B 1 USS Interface DB9F E Power Supply Input See also B 1 Power Connector C 1 Technical Specification F DIN rail Mechanism The DIN rail mechanism works as follows To snap the gateway on first press the 1t downwards 1 to compress the spring in the DIN rail mechanism then push it towards the DIN rail as to make it snap on 2 To snap the gateway off push the it downwards 1 and pull it out from the DIN rail 2 as to make it snap off Status LEDs State 1 Comm Status Off Introduction 1 3 Stat gt o a us lOO Off line vd se O das connection with 1O Controller O O Green On line RUN Connection to IO Controller established 10 Controller is in RUN state Green flashing On line STOP Connection to IO Controller established IO Controller in STOP state 2 Module Status Off No power or not initialized
25. s the data sizes PKW and PZD Set me ere ee of the slave which shall be added EA A Specify Module 4 Repeat steps 1 3 for all USS slaves which shall be included in the configuration Go To gt Filter Assigned Modules Monitor Modify Example Edit Symbols Object Properties Alt Return Example with a single USS slave with the following properties Product Support Information Ctrl F2 FOS Chrl F7 Find Manual Ctrl F6 Slave address 1 4words of Parameter Data PKW 16 words of Process Data PZD HW Config SIMATIC 300 1 Station Edit Insert PLC View Options Window Help plels a Bj S e dli Ethemet 1 PROFINET 10 System 100 ml 48C Us Kal 1 ABC USS PRT Slot 4 Module Order Number Address O address Diagnostic address Comment Ela ABCLUSS ABT MEELISS PBT es ee ee 1 Ng words PKW 04 PZD 16 a CCA 3 a words PKW 00 4 words PRW 00 words Pkw 00 ___ ____ _________ J words Prw o0 _ _________ words PR W 00 words PKW 00 words PRW 00 A ececte Er A A i ie Note The ranges shown in the I Address and Q address columns includes space for the Slave Status Register in both Puc directions i Upload Download Module Identification Upload Module Identification to PG Faulty Modules Step 4 Downloading the Configuration Module Information Ctrl D Operati
26. tion is based on the PROFINET GSD file which can be downloaded from the HMS web site www anybus com TCP IP Settings To participate on the PROFINET network the gateway needs a valid TCP IP configuration The gate way fully supports the DCP protocol allowing the IO Controller Supervisor to change the TCP IP set tings of the gateway during runtime In addition the gateway supports DHCP and Anybus IPconfig HICP The TCP IP settings can also be accessed via the web based configuration interface When using DHCP the gateway will attempt to retrieve the TCP IP settings from a DHCP server dur ing startup If no DHCP server is found the gateway falls back to its current settings 1 e any manual settings that may have been specified earlier If no current settings are available 1 e if the previous settings are invalid the gateway will halt and in dicate an error on the on board status LEDs The TCP IP configuration may however still be accessed via Anybus IPconfig HICP See also e 4 2 IP Address Settings e A 1 Anybus Pconfig HICP SMTP Account Setting In addition in order to be able to send notification messages via email the gateway needs a valid SMTP server account These settings can be accessed through the web based configuration interface See also e 4 2 IP Address Settings Network Configuration 3 2 Station Name General Information When used for the first time the gateway nee
27. ts EN 61000 4 2 1995 8kV Air Discharge 4kV Contact discharge EN 61000 4 4 1995 2kV Power port 1kV Other ports EN 61000 4 5 1995 0 5kV Power ports DM CM 1kV Signal ports UL c UL compliance The certification has been documented by UL in file E214107
28. ue must be between 5 7 lbs in 0 5 0 8 Nm USS Interface DB9F Pin Signal Notes 1 5V Output 100mA max 2 do not connect 3 4 5 female 1 5 Signal Ground IMPORTANT This pin should only be connected to the Signal DOS Ground of other nodes if available lt must not be connected to Pro tective Earth PE since doing so may cause serious damage to the serial transceivers in the gateway do not connect RS485 RS485 o CO J O Appendix C Technical Specification Mechanical Properties Housing Plastic housing with snap on connection to DIN rail protection class IP20 Dimensions 120 mm x 75 mm x 27 mm Lx W x H inches 4 72 x 2 95 x 1 06 Lx W x H Electrical Characteristics Power Supply Power 24V 10 Power Consumption Maximum power consumption is 280mA Typically around 100 mA Environmental Characteristics Relative Humidity The product is designed for a relative humidity of 0 to 95 non condensing Temperature Operating 10 C 10 55 C Non Operating 25 C to 85 C Technical Specification C 2 Regulatory Compliance EMC Compliance CE This product is in accordance with the EMC directive 89 336 EEC with amendments 92 31 EEC and 93 68 EEC through conformance with the following standards EN 50082 2 1993 EN 55011 1990 Class A EN 61000 6 2 1999 EN 61000 4 3 1996 10V m EN 61000 4 6 1996 10V m all por