Home

F7_F707_F708

image

Contents

1. 26 F7_F707_F708 Installation Instruction V1 0 Place your finger on the sensor for a full 2 seconds After the F7 scans your fingerprint successfully it will beep and then prompt you briefly with New Enroll 00001 1 Remove Finger ESC Exit Then you ll be prompted New Enroll 00001 1 Second Press ESC Exit s97 F7_F707_F708 Installation Instruction V1 0 Remove your finger and then place your finger on the sensor a ay time Again you ll be prompted briefly New Enroll 00001 1 Remove Finger ESC Exit Remove your finger and then place your finger on the sensor a 3 and final time You ll then be prompted New Enroll 00001 0 ESC OK Save Press the QJ key to accept the newly enrolled finger The F7 will then prompt you with New Enroll Continue ESC OK 28 F7_F707_F708 Installation Instruction V1 0 UserID 0001 has now been successfully enrolled with one fingerprint If you wish to continue enrolling additional users press the key and follow the same procedures If you re finished enrolling additional users press the ESC cancel key repeatedly until you return the Start Up window Welcome Check In HH MM MM DD YY DAY Note The actual current date time will appear Test the newly enrolled fingerprint by having UserID 00001 place his her finger on the sensor If successful the F7 w
2. cccecceccccsccccccccccccceccecceccesccsecsesseees 31 5 0 Trouble shooting ccsccccccscccccccscccccescecccsccesscesces 32 F7_F707_F708 Installation Instruction V1 0 Before Installation Prior to beginning installation cut off all power to prevent personal injury and damage to the F7_F707_F708 and peripheral equipment Connect the ground wire first in order to prevent electro static damage to the F7_F707_F708 Connect 12V DC power supply to the F7_F707_F708 last If the F7_F707_F708 does not operate properly always cut off power to it before examining dismantling Be advised that wiring the F7_F707_F708 while power is on may cause damage to the terminal Possible resulting damage from not powering off the F7_F707_F708 prior to wiring is not covered by manufacturer s warranty Mount the F7_F707_F708 at a comfortable height typically between 4 and 5 feet from the ground After installation remove protective film from the F7 F707 F708 display and fingerprint sensor To prevent being accidentally locked out while testing the exit door button keep a person on the inside of the door Run the auto test function to confirm that installation is successful IE 10 11 12 13 F7_F707_F708 Installation Instruction V1 0 In order to maximize the life of the F7_F707_F708 use the auto sleep and wake up functions ONLY use a 12V DC 1 5Amp power supply for proper functioning of the F7_F707_F708 term
3. 15 GND GND RS232 RxD 12V Power RS232 TxD Lock COM GND Lock NO RS485 A Lock NC RS485 B GND GND Alarm DATAO Alarm DATA1 Button 5V Output GND Door Sensor Bell GND Bell F7_F707_F708 Installation Instruction V1 0 1 8 Connecting network or computer F7_F707_F708 offers RS232 and RS485 interface or Ethernet connectivity to connect with a computer network Ethernet connection Option 1 Direct connection to PC via cross over cable IP 192 168 1 101 Mask 255 255 255 0 Option 2 Indirect connection to PC via network router Switch 16 F7_F707_F708 Installation Instruction V1 0 Door Sensor GND 217 F7_F707_F708 Installation Instruction V1 0 RS485 connection RS 485 systems using a bus structure configuration connect the driver to the receiver The transmission line is made by a group of twisted pair cables Each cable has a pair of conductors consisting of inverted and non inverted signal lines The inverted line is generally designated by the letter A or with the non inverted line designated as B or In order to eliminate or reduce noise traditional RS485 networks require a 12Q terminal resistor to be installed at the end of the bus cables based on the physical layout of the twisted pair cables In the normal condition the resistor is not installed only if the bus is extended over 125 feet th
4. 08 Installation Instruction V1 0 1 0 Installation 1 1 Attach Mounting Plate 1 Take out the F7_F707_F708 fingerprint terminal and remove the screw screwdriver supplied which secures the F7_ F707 F708 to its mounting plate pri 3 gt Bi i 2 Remove mounting plate by grasping the bottom edge and lifting it inward and upward 3 Determine the position of mounting plate on the wall We recommend about 4 5 feet from the ground so it is comfortably within reach of most of your users F7_F707_F708 Installation Instruction V1 0 After its position is determined cut out square openings in the walls which correspond to the cut outs in the F7_F707_F708 s mounting plate for wires to pass through Door Sensor ONO Use 3 mounting screws supplied to affix the F7_F707_F708 mounting plate on the wall Then secure the F7_F707_F708 to the mounting plate F7_F707_F708 Installation Instruction V1 0 1 2 Connecting Power Supply F7_F707_F708 operates on 12V DC Power supply and connect the positive and GND as shown below If you are connecting a magnetic lock or an electric strike to F7_F707_F708 than we recommend it should draw maximum current of 1A If you need more power than please use an external power supply of higher current capacity GND GND RS232 RXD 12V Power RS232 TXD Lock COM GND Lock NO RS485 A Lock NC RS485 B GND GN
5. 707_F708 Installation Instruction V1 0 Press the QJ key Scroll with the A V keys and place the cursor alongside Enroll User User Manage y gt Enroll User Enroll Admin Press the key Scroll with the A V keys and place the cursor alongside Enroll FP Enroll User y gt Enroll FP Enroll Pwd FP amp Pwd 93 F7_F707_F708 Installation Instruction V1 0 Press the key The F7 will prompt you Enroll FP New Enroll ESC OK Press 0 lt Enroll FP New Enroll ESC OK Since we are enrolling a New User press The F7 will then prompt you with the next available User ID New Enroll UserID UO ESC OK In this example no user has yet been enrolled on the F7 So the next available User ID is 00001 24 F7_F707_F708 Installation Instruction V1 0 Press the OK key to accept 00001 or manually key in a different number if desired The F7 will then prompt New Enroll 00001 0 Place Finger ESC Exit 25 F7_F707_F708 Installation Instruction V1 0 Remember the rules for proper finger placement The user s finger should completely cover the sensor The finger should be placed flat and in the center of the sensor The finger should cover at least 80 of the sensor as shown below The finger should NOT be placed in the following positions Not flat Not centered Not flat Not centered
6. D Alarm DATAO Alarm DATA Button 5V Output GND Door Sensor Bell GND Bell 12V DC Power sunnlv adanter F7_F707_F708 Installation Instruction V1 0 1 3 Selecting door lock For glass doors which swing both in and out we recommend the use of electro magnetic door strikes aka mag locks For 1 way opening non glass doors we recommend the use of electric door strikes instead While both locks are equally secure the mag lock is considered safer than the electric strike especially during power interruptions During a power failure caused by fire or other safety threats the mag lock will fail open and allow people to exit a room building unhampered Conversely the electric strike fails closed With loss of power you can still exit a door secured by an electric door strike But you ll need a mechanical device i e door handle or exit bar to free the door during power interruptions ZK Software is not responsible for any personal injury or damage caused by power failure 10 F7_F707_F708 Installation Instruction V1 0 1 4 Connecting an electric strike or magnetic lock F7_F707_F708 has NO and NC closed contacts for controlling the locks Since there are many different type s of locks available we recommend to connect these locks as per the recommendation of the manufacturers Ensure that proper voltages are applied to the lock terminals and check on the current ratings of the lock
7. F7_F707_F708 Installation Instruction V1 0 F7 F707 F708 Access Control Terminal Installation Instructions L About this Guide Revised May 2008 This guide provides installation instructions only For information regarding actual operation and configuration of the F7_F707_F708 Time amp Attendance and Access Control Terminal refer to the user manual F7_F707_F708 Installation Instruction V1 0 Table of Contents Before Installation rrsrrrsrrserere rece zece rece zece cere cere ceca cesececn cere cecezenenene 1 Front and Read Panel views sssecsccsscccccccccccccccsccsccecees 5 Optional 3 Party Equipment sssssssssssseessesesesesseeceess 6 1 0 Installation nnua 7 1 1 Attaching Mounting Plate 0 0 7 1 2 Connecting Power Supply 0 9 1 3 Selecting Door Lock cece ec ee cence cnet ene enneenes 10 1 4 Connecting an electric strike or magnetic lock 11 1 5 Powering Door Lock Li 13 1 6 Connecting switches door sensor doorbell etc 14 1 7 Connecting 3 party door controller panel 16 1 8 Connecting network or computer 17 ZO Testino Leo his aaa ia 20 2 1 Run Auto Test 20 2 2 Test Fingerprint EnrolIment i 23 3 0 Fastening to mounting plate and wall ccseesesseceeees 30 4 0 Miscellameous
8. connections are secure Also make sure network firewall settings are not blocking communication to the F7_F707_F708 Cause The F7_F707_F708 s fingerprint sensor may have accumulated excess dirt or scratches over a period of time This message indicates the sensor is unable to obtain a clear image of the fingerprint Other possible cause may be fingerprint sensor cable has loosened from circuit board Fix Try using cellophane tape to remove dirt Sensor may also need to be repaired replaced F7_F707_F708 starts up but cannot enter menu system Cause Fingerprint sensor cable is loose Fingerprint sensor is broken Circuit board is broken Fix Remove and plug back in Fingerprint sensor cable 239 2 F7_F707_F708 Installation Instruction V1 0 Time continually displays 00 00 after restarting Cause The clock battery is drained Fix Replace battery The fingerprint sensor light is off Cause Fingerprint sensor or flat connection cable is loose or broken Fix Unplug the cable from the fingerprint sensor and plug it back in again Pressing buttons no longer makes sound Cause Trouble in the buzzer loudspeaker or circuit Fix Need to replace the buzzer and loudspeaker Some users finger prints sometimes can t be verified Cause The fingerprint quality is poor Fix If repeated attempts with the same finger fail try using a different finger when e
9. e power to the door 13 F7_F707_F708 Installation Instruction V1 0 1 6 Connecting switches door sensor doorbell etc You can connect the exit switch as shown below This is mainly used for receptionists to open the door for the visitors The door sensor switch is used to trigger the alarm if the door is kept open for more than specified time Furthermore F7_F707_F708 will also send an alert signal if the door is not closed within the specified time You can connect a doorbell to the F7_F707_F708 as shown below Visitors can hit this button which will trigger the door bell inside the door GND GND RS232 RxD 12V Power RS232 TxD GND RS485 A RS485 B GND DATAO DATAI 5V Output Doorbell Door Sensor GND 14 F7_F707_F708 Installation Instruction V1 0 1 7 Connecting 3 party door controller panel The F7_F707_F708 provides standard Wiegand 26 bit output which can be connected to most 3 party access control panels The F7_F707_F708 connects to the panel just like any card reader or keypad The distance from the controller to the F7_F707_F708 cannot be more than 200 feet If the Wiegand signal must be transferred much further or if electro magnetic interference exists utilize a Wiegand signal amplifier Use the following connections Access Controller GND DATAO DATAI 12V
10. e termination must be connected with a terminal resistor 18 F7_F707_F708 Installation Instruction V1 0 2 0 Test and examine after installation With power on test for the following v The green LED lights up after power up v 2 1 Run Auto test Press the MI Menu key on the F7 F7_F707_F708 Installation Instruction V1 0 Scroll with the A V keys and place the cursor alongside Options Menu y User Manage gt Options Press the QM key The Options Menu will appear Options A y Log Opt Access Options gt Auto Test Scroll with the A V keys and place the cursor gt alongside Auto Test 20 F7_F707_F708 Installation Instruction V1 0 Press the OK key The following screen appears AutoTest y gt Run ALL Test LCD Test Voice Test FR Reader Key test RTC Test Scroll with the A V keys and place the cursor alongside the feature yov d like to test and press the OK key When finished testing continue pressing the Cancel ESC key repeatedly until you return to the Start Up window Welcome Check In HH MM MM DD YY DAY Note The actual current date time will appear 21 F7_F707_F708 Installation Instruction V1 0 VY 2 2 Test Fingerprint Enrollment Press the MI Menu key on the F7 Scroll with the A V keys and place the cursor alongside User Manage Menu y gt User Manage Options DI F7_F
11. ill respond with an audible Thank you and the screen will display Verify Pin Weel Verified 29 F7_F707_F708 Installation Instruction V1 0 3 0 Fasten F7_F707_F708 to mounting plate wall v v Confirm all connecting wires are correct and securely fastened Properly align the rear metal plate of the F7_F707_F708 to the mounting plate and then push up on it Then push the F7_F707_F708 backwards The F7_F707 F708 is now securely affixed to the mounting plate and wall 30 F7_F707_F708 Installation Instruction V1 0 4 0 Miscellaneous 4 1 Reset IMPORTANT NOTE Resetting the F7_F707_F708 does NOT erase any stored data i e templates transactions settings This information will be available as soon as power is restored To reset the F7_F707_F708 use a small tool e g pin or paperclip to push in the reset button labelled reset located on the underside of the F7_F707_F708 see figure below 4 2 Tamper proof button When the F7_F707_F708 detects it is being tampered with it will send an alarm signal 314 Appendix 5 0 Trouble shooting Trouble Cause amp Fix Power LED is off Cause No power or lack of voltage F7_F707_F708 is unable to connect with PC LCD displays Please try again Fix Check and examine power and ground connections Also ensure 12V DC power Cause Connection may be loose Fix Check that the RS232 RS485 or Ethernet
12. inal Ifthe incorrect voltage is used the F7_F707_F708 may keep rebooting or may not operate the electric door lock if attached Improper wiring may cause the F7_F707_F708 s main circuit board and fingerprint sensor to burn out Resulting damage from improper wiring is not covered under manufacturer s warranty Only use supplied transformer and cord Do not attempt extending the cord by cutting and splicing If using RS485 mode of communication use only a ZK Software supplied RS485 converters Using a 3 party RS485 converter may or may not work If the RS485 cable length exceeds 200 feet we recommend using a 120 terminator Refer to the user handbook and operating instructions for further information F7_F707_F708 Installation Instruction V1 0 Front panel view Loudspeaker LCD display Fingerprintsensor Op Mountingholes Ethernet port ci ol 12V Powel Lock ci Loe Loc MM Relaycontacts 2 s 2 5 l AZIZ eae 5 2 Mounting hole F7_F707_F708 Installation Instruction V1 0 Optional 3 party equipment The following equipment is not provided by ZK Software but often compliments a complete Access Control solution Part Image Part Image PC w j Door BA Lock 1 el lt LI O Exit Door sensor gt Button m a RS485 Cowen o Alarm RS232 gt converter Door Network Controller Cable F7_F707_F7
13. nrolling Also reduce fingerprint threshold setting Ifuser s fingerprints completely unreadable assign them a PIN number instead 2334
14. s GND GND RS232 RxD 12V Power RS232 TxD Lock COM GND Lock NO RS485 A Lock NC RS485 B GND GND Alarm DATAO Alarm DATAI Button 5V Output GND Door Sensor Bell GND Bell 12V Power supply adapter ll F7_F707_F708 Installation Instruction V1 0 GND GND RS232 RxD 12V Power RS232 TxD Lock COM GND Lock NO RS485 A Lock NC RS485 B GND GND Alarm DATAO Alarm DATAI Button 5V Output GND Door Sensor Bell GND Bell GND GND RS232 RxD 12V Power RS232 TxD Lock COM GND Lock NO RS485 A Lock NC RS485 B GND GND Alarmt DATAO Alarm DATAI Button 5V Output GND Door Sensor Bell GND Bell 12V Power supply adapter 12V Power supply adapter Lock Power f Lock control relay 2124 F7_F707_F708 Installation Instruction V1 0 1 5 Powering Door Lock The F7_F707_F708 can supply power directly to a door lock However in the following three scenarios it is recommended that the door lock has an independent power source and is NOT powered by the F7_F707_F708 e Ifthe door lock voltage is not 12V DC then provide separate power to the door lock e Ifthe door lock runs on 12V DC but requires more than 1A amp then provide separate power to the door lock If the distance between the F7_F707_F708 and door lock is greater than 15 feet then provide separat