Home
Setting of the Control Board
Contents
1. 1 Start with gate in closed position 2 There are four sections of steel rack which is one meter length each section for standard package you can order extra rack from dealer if necessary 2 Put one end of rack section on the gear of opener as a temporary support Make rack level and mark the rack s mounting holes three holes on the gate 3 Weld the rack nut on the gate as mark and connect the rack to the gate using the bolt provided Before weld please keep 1 0mm space between the rack and the gear to avoid the weight of the gate leaf effect on the opener d Lower Magnet Component Base Plate Concrete Pad Important Check that the rack teeth must engage the gear teeth throughout their full thickness If not adjust the position of the opener or and place a few shims between the rack and gate 4 Manually slide the gate leaf to ensure the rack is proper on the gear of opener weld the second nut 5 Repeat same steps of first rack section to install the rest rack sections until proper length is reached 6 Cut away any excess of the rack Note rack length must be longer than actual travel of the gate to accommodate limit switch brackets on each gate side 7 Thoroughly fasten the four nuts as well as spring washers onto expansion bolt tightly enabling the opener is firmly secured on the concrete pad during the whole gate travel Installation of the magnets for the Limit Switches Before install limit switch make
2. E For gate openers utilizing Type D protection 1 The gate opener controls must be placed so that the user has full view of the gate area when the gate is moving 2 The placard provided marked in letters at least 1 4 in 6 4 mm high with the word WARNING and the following statement or the equivalent Moving Gate Has the Potential of Inflicting Injury or Death Do Not Start Gate Unless Path is Clear shall be placed adjacent to the controls 3 An automatic closing device such as a timer loop sensor or similar device shall not be employed 4 No other activation device shall be connected F Controls intended for user activation must be located at least ten feet 10 away from any moving part of the gate and where the user is prevented from reaching over under around or through the gate to operate the controls Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use Be sure to mount ALL operating devices clearly out of reach of through gate py M G The Stop and or Reset button must be located in the line of sight of the gate Activation of the reset control shall not cause the opener to start H A minimum of two 2 WARNING SIGNS shall be installed one on each side of the gate where easily visible Moving Gate Can Cause Injury Or Death 1 Keep Clear Gate may move at any time For a gate opener utiliz
3. after power off How to learn or erase the remote Learn the remote Press and release the learn button the REM LED light will be on then press the key in the s LEARN remote twice in 2 seconds the REM LED light will flash for 4 seconds Now the PWR LED le remote has been learnt successfully PWR ad E 2 2 Learn Button Erase all the remote codes E Press and hold the learn button until the REM LED light is off Now all remote codes have been erased Key A REMOTE Key B How to use the remote to control the operator Key A is used to operate the operator to work alternately open stop close stop open When the Midway Mode function is enabled Key B is used to achieve the Midway Mode function open the gate for the pre setting time When the Midway Mode function is disabled the operator works alternately open stop close stop open by pressing Key B Troubleshooting Have a multimeter to check voltage and continuity Use caution when checking high voltage terminals 1 Motor only runs toward one direction a The limit switch is failed Disconnect the limit switches and try it again b The start capacitor of the motor is failed Replace the capacitor c The electric component on the control board may be damaged Replace the electric component or replace the control board 2 The gate does not open or close a The power switch is OFF Make sure the power switch is ON b The limit switches are fai
4. its packing and inspect it for damage Should it be damaged contact your dealer Remember to dispose of its components cardboard polystyrene nylon etc according to the current prescriptions Refer to the following Figures for gate installation Using the post or wall as a stop either directly or indirectly is not recommended so as to protect the post or wall against damaging shock from the sliding gate Incorrect Positive Stop in fully closed position It is suggestion that there is a 4 10cm distance at least between the gate edge and the gate wall when the gate is fully open 4 minimum Positive Stop in fully opening position Parts List a e LO tr Expansion Bolt 4 pcs Remote Control 2 pcs Hex Bolt M8x30 Spring Washer Galvanized Steel Rack 1005mmxN pcs Optional Key 2 pcs Release Key 1 pc Magnet Assembly 2 pcs Plain Washer Pan Head Screw 4 pcs M5x10 8 pcs we coU fa Plastic Rack Reinforced with Steel 1005mmxN pcs Optional Technical Specifications amp Features Specifications Power supply 120V 60HZ or 230V 50HZ Motor 120VAC or 230VAC Absorbed power SFG18 370W SFG21 550W Gate moving speed 7 9 second 20 cm second Max gate weight SFG18 800KGS SFG21 1200KGS Max torque SFG18 24Nm SFG21 35Nm Environmental conditions from 15 C to 40 C Protection class 1 44 Dimen
5. the two brackets position b Please try to exchange the limit switch wires CL close and OP open There are two reed switches inside the magnetic limit switch one is upper and another is lower Maybe the magnet position was installed in the middle so it inducts both switches Adjust the magnet upper or lower 6 The gate can open but fails to close a Photocell is obstructed Remove obstruction b The limit switch is failed Disconnect the limit switches and try it again c The start capacitor of the motor is failed Replace the capacitor d The electric component on the control board has been damaged Replace the electric component or replace the control board 7 The motor runs but the gate doesn t move The clutch for emergency release is adjusted properly and is not slipping Maintenance Every six months check the following items for proper operation of the unit Lubricate shafts and sprockets Keep operator clean at all times Check and tighten anchors bolts Check for loose or corroded wire Ensure the operator is well earthed and correctly terminated Always check the Stop Reverse in case of obstruction function when performing any maintenance If this function can t be made operable remove this operator from service until the cause of the malfunction is identified and corrected www WholesaleGateOpener com 7106 S 220th St Kent WA 98032 USA sales WholesaleGateOpener com 2010 2012 LockMaster All R
6. LockMaster Sliding Gate Operator User s Manual SFG 18H 21H Please read and follow all warnings precautions and instructions before installation and use Periodic checks of the opener are required to ensure safe operation For residential use only Save this manual www WholesaleGateOpener com Rev 11a Table of Contents General Safety ah Sle del aud en ia eae La eed ae Dade 2 Important cece ee eee cece Na e e ne eese ris 3 Preparation for Installation omiiia bie ERG eru endo ERE RER SER datioun redes 5 EISU 1x sies Ere Dux dau EUR NR M I Eie d VM 6 Technical Specifications amp Feature sse ese ehe ee eee enirn 7 Installation OVeErnvView D eed ade aka cen se ads Tek ete edad en eee 8 Installation of the Opener 8 Manual Operation surera rear 9 Fit The 9 Installation of the Limit Switch ssssssssssssssssesmImmmememene 11 Connecting of the Control Board eee eee tesa e eet eterne nnne 11 Setting of the Control Board sss 13 Test the reversing sensitivity 0 ccc ene ee eee eee eene menses nnn esent enne 14 How to learn or
7. ardware 7 The entrance is for vehicles only Pedestrians must use separate entrance 8 SAVE THESE INSTRUCTIONS Safety Instructions for Installation A Install the gate opener only when 1 The opener is appropriate for the construction of the gate and the usage Class of the gate 2 All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet 1 22 m above the ground to prevent a 2 1 4 inch 57 2 mm diameter sphere from passing through the openings anywhere in the gate and in that portion of the adjacent fence that the gate covers in the open position 3 All exposed pinch points are eliminated or guarded 4 Guarding is supplied for exposed rollers B The opener is intended for installation only on gates used for vehicles Pedestrians must be supplied with a separate access opening The pedestrian access opening shall be designed to promote pedestrian usage Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate C The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment D The gate must be properly installed and work freely in both directions prior to the installation of the gate opener Do not over tighten the opener clutch or pressure relief valve to compensate for a damaged gate
8. ation Do not install the product in explosive atmosphere The factory declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when constructing closing structures door gates etc as well as from any deformation which might occur during use Disconnect the electrical power supply before carrying out any work on the installation Also disconnect any buffer batteries if fitted Fit an omnipolar or magnetothermal switch on the mains power supply having a contact opening distance equal to or greater than 3 5 mm Check that a differential switch with a 0 03A threshold is fitted just before the power supply mains Check that earthing is carried out correctly connect all metal parts for closure doors gates etc and all system components provided with an earth terminal Fit all the safety devices photocells electric edges etc which are needed to protect the area from any danger caused by squashing conveying and shearing Position at least one luminous signal indication device blinker where it can be easily seen and fix a Warning sign to the structure The factory declines all responsibility with respect to the automation safety and correct operation when other supplier s components are used Only use original parts for any maintenance or repair operation Do not modify the automation components unless explicitly authorized by the factory Instruct the product
9. erase the remote ete eene esee nens 15 How to use the remote to control the operator ssssssssssssss Immer 15 Tro bl Shooting oor exert est peak 15 Maintenance c D RN 16 Thank you for purchasing SFG18 21H sliding gate opener We are sure that the products will be greatly satisfying as soon as you start to use it The product is supplied with a user s manual which encloses installation and safety precautions These should be read carefully before installation and operation as they provide important information about safety installation operation and maintenance This product complies with the recognized technical standards and safety regulations General Safety A WARNING An incorrect installation or improper use of the product can cause damage to persons animals or properties Scrap packing materials plastic cardboard polystyrene etc according to the provisions set out by current standards Keep nylon or polystyrene bags out of children s reach This product was exclusively designed and manufactured for the use specified in the present documentation Any other use not specified in this documentation could damage the product and be dangerous The factory declines all responsibility for any consequences resulting from improper use of the product or use which is different from that expected and specified in the present document
10. ights Reserved
11. ing a non contact sensor in accordance Usage Class 1 See instructions on the placement of non contact sensors for each Type of application 2 Care shall be exercised to reduce the risk of nuisance tripping such as when a vehicle trips the sensor while the gate is still moving and in the opening direction 3 One or more non contact sensors shall be located where the risk of entrapment or obstruction exists such as the perimeter reachable by a moving gate or barrier J For a gate opener utilizing a contact sensor in accordance with Usage Class 1 One or more contact sensors shall be located where the risk of entrapment or obstruction exists such as at the leading edge trailing edge and post mounted both inside and outside of a vehicular horizontal slide gate 2 One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate 3 One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate 4 A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate opener is not subjected to mechanical damage 5 A wireless contact sensor such as one that transmits radio frequency RF signals to the gate opener for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures natural landscaping or similar obstruction A wireless contact sen
12. itch The process is as follows 1 Insert and turn the key clockwise 45 to slide the lock cover Now the key slot appears 2 Insert the T handle Key provided to the key slot and turn it in counter clockwise 135 to disengage the clutch between the gear shaft and power output Now the opener is in the manual operation Release Fit the Rack There are two kinds of rack available as per buyer s option which are steel reinforced plastic rack and galvanized steel rack The galvanized steel rack is usually used for the heavy duty gate A Fit the plastic rack reinforced with steel 1 Start with gate in closed position 2 There are four sections of plastic rack which is one meter length each section for standard package you can order extra rack from dealer if necessary 2 Put one end of rack section on the gear of opener as a temporary support Make rack level and mark the rack s mounting holes four holes on the gate 3 Fit the rack by self threading screws This kind of plastic rack is quieter and allows height adjustments to be made even after it has been fixed Please keep 1 0mm space between the rack and the gear to avoid the weight of the gate leaf effect on the opener Plastic rack Pan head Screw reinforced with steel for Magnet Bracket Higher Magnet Component Y Lower Magnet Component Operator Self threading Screw Base Plate amp plate Concrete Pad B Fit the galvanized steel rack
13. ition of the gate operator installed 000000 seems LA LB U Ww V DIP Switch 1 2 Running time of the motor in Midway Mode This mode enables user to drive the vehicle through the gate quickly when the gate opens to certain width DIP Switch 1 ON 2 Seconds OFF 0 DIP Switch 2 ON 4 Seconds OFF 0 NOTE The midway function would be disabled if both DIP switches are turned off Factory default setting is disabled ON Es PIE Running time of the operator in midway mode is 2 4 6 seconds 12345 DIP Switch 223 424 Auto close time of the gate operator DIP Switch 3 ON 30 Seconds OFF 0 13 DIP Switch 4 ON 60 Seconds OFF 0 NOTE The auto close function would be disabled if both dip switches are turned to off factory default setting ON E g B Auto close time of the gate operator is 30 60 90 seconds 12345 DIP Switch 5 Left Right open ON Left open factory default setting OFF Right open Turn switch OFF to change the opening direction easy if necessary gt ON Left open factory default setting For gate to open toward left and close toward right OFF Right open For gate to open toward right and close toward left o m m 0 2 Potentiometers The potentiometer A is to adjust the OPEN stall force of the gate operator The Potentiometer B is used to adjust the CLOSE s
14. ld be connected to the 12 and 13 terminals in parallel Use another 2 cable to connect the NO terminal of the receiver to the 14 terminal the terminal to the 15 terminal 6 Push Button Optional The push button should be wired to the 15 and 16 terminals The gate operator works alternately by pushing the button open stop close stop open 7 Loop Detector Optional First insert the LOOP DETECTOR BOARD into the CONTROL BOARD and then connect the twisted pair to the 17 and 18 terminals 8 External Receiver Optional The BROWN wire of the external receiver should be connected into the 16 terminal The BLACK wire of the external receiver should be connected into the 13 terminal The RED wire of the external receiver should be connected into the 12 terminal 9 Wired Keypad 12VDC Optional The RED wire of the wired keypad should be connected into the 12 terminal The BLACK wire of the wired keypad should be connected into the 13 terminal The WHITE wire of the wired keypad should be connected into the 16 terminal The BLUE wire of the wired keypad should be connected into the 15 terminal Setting of the Control Board 1 DIP Switches The DIP switches are used to set Control Board the running time of the motor in midway mode auto close time of the gate operator and fast change the open close direction which is determined by the pos
15. led Disconnect the limit switches and try it again c Connecting wires or terminal blocks are too loose Check the connecting wires and terminal blocks d The motor has been damaged Replace the motor if necessary e The thermal protector is working because the high temperature after long working time Please wait for 20 minutes to let the motor become cold 15 f The electric component on the control board has been damaged Replace the electric component or replace the control board 3 Remote control does not work a The distance you use the remote is too far away from the opener Try it again closer b Remote control is not suitable for receiver After making sure the codes are correct erase remote controls and then re program the codes in the device c Broken receive board Replace receive board d The indicator light of remote control is not on Check the battery in your remote control Replace the battery if necessary 4 When you open or close the gate by pressing key 1 and key 2 which have been programmed gate will stop in mid travel or reverse before reaching the fully limit position a The opening force or closing force is adjusted too small Turn the Potentiometer 1 and 2 to increase the force b Gate is obstructed Remove the obstruction 5 The gate opens but stops and will not return a Please note the two magnet brackets fixed plate are different one is higher and another is lower Please try to exchange
16. olt _ build a concrete pad to support the base 4 pes plate of opener in order to maintain proper stability Base Plate 1 pc 0 100 mm The installation proceeds are as follows 1 Dig a hole for a concrete pad which should be approximately 50 x 30 x 35cm 20 x 12 x 14 It may protrude 10 cm 4 above ground and 25 cm 10 in Conduit depth underground Increase the pad height if necessary to protect the system from flooding heavy snow etc 2 Prepare one or more conduits for the electrical cables before pour concrete Remember that cable conduits have to pass through the hole in the base plate Cable Concrete Pad 3 Pour concrete and before it starts to harden check that it is parallel to the gate leaf and perfectly level 4 Mark the position of four expansion anchors according to the position of mounting hole on the base plate as soon as concrete become harden Double check your marking move the base plate and drill the 4 holes using a 10mm 3 8 masonry bit Put the 4 expansion anchors provided into the holes and firmly tighten 5 Place the opener onto base plate Check that it is perfectly parallel to the gate leaf and then screw the four nuts and washers supplied It s only temporary installation Further adjustment will be required when install the rack or chain Manual Operation The opener should be put in the manual emergency release position before fitting the rack installing the opener and limit sw
17. or The BLACK wire of the motor should be connected into the 6 terminal The RED wire of the motor should be connected into the 7 terminal The YELLOW wire of the motor should be connected into the 8 terminal 2 Start Capacitor One pin of the start capacitor should be wired to the 7 terminal another to 8 terminal 3 Limit Switches The RED wire of the limit switches should be connected into the 9 terminal The BLACK wire of the limit switches should be connected into the 10 terminal The YELLOW wire of the limit switches should be connected into the 11 terminal 11 ED 18 7 ow nus PHOTO osie lona SUD es Cs emus n LAJ E nmi EE EE aj sa UP DN cocccoccoc i ill a d Input Loop Detector LM154 AC IN ae Start Capacitor YELLOW I _ 16 LES Push Button LM145 Photocell LM102 Limit Switches Emitter Recaiver 4 Alarm Lamp LM140A Wired Keypad LM106 12 4 Alarm Lamp Optional One wire of the alarm lamp should be connected into the 4 terminal another should be connected into the 5 terminal 12 5 Photocell Normal Open Optional Use a 2 core cable to connect the terminal of the photocell s emitter to the 12 terminal the terminal to the 13 terminal Also the and terminals of the photocell s receiver shou
18. sions 38x28x36 CM Class of gate opener 1 11 Features Easy to install and low maintain Midway mode Quick selection for gate open close direction Reliable rolling code technology Emergency release key in case of power failure Stop Reverse in case of obstruction during gate opening closing Built in adjustable auto close 5 100 seconds Built in max Motor running time MRT adjustable for multiple safety protection 5 100 seconds Reliable electromagnetism limit for easy adjustment Can be equipped with wide range accessories Installation Overview Sliding Gate Alarm Lamp Higher Magnet Concrete Pad Gate Operator Rack Lower Magnet Photocell Installation of the Opener Caution Be sure that the opener is installed in a level and paralleled position and is properly secured Improper installation could result in property damage severe injury and or death Before starting installation ensure that there is no point of friction during the entire movement of the gate and there is no danger of derailment Ensure that the safety side panels are present Necessary Tools The following tools may be necessary to install the Gate Pond cia asi 5 opener You will need screwdrivers an Plain Washer 8 4 pcs electric drill wire cutters and a wire stripper a socket set and possibly access to a welder When install the opener you should Operator Expansion B
19. sor shall function under the intended end use conditions 6 One or more contact sensors shall be located on the inside and outside leading edge of a sliding gate Additionally if the bottom edge of a sliding gate is greater than 6 inches 152 mm above the ground at any point in its arc of travel one or more contact sensors shall be located on the bottom edge 7 One or more contact sensors shall be located at the bottom edge of a vertical barrier arm Preparation for Installation Before proceeding to your opener installation check if your gate structure is in accordance with the current standards especially as follows The gate sliding track is linear and horizontal and the wheels are suitable the gate should be mounted and moving freely Check that the structure is sufficiently strong and rigid and that its dimensions and weights conform to those listed in the specifications table of this document Make sure that the gate is plumb and level The fence posts must be mounted in concrete The gate does not bind or drag on the ground The gate manual operation can be carried out smoothly along its entire run and there is no excessive side slipping The opening and closing gate stops are positioned A WARNING Remember that control devices are intended to facilitate gate operation but can not solve problems due to any defects or deficiency resulting from failure to carry out correct installation or maintenance Take the product out of
20. sure the gate opener is put in manual operation the clutch connected with gear shaft is disengaged and the mains power supply is disconnected Position the two limit stop brackets approximately on the rack and move the gate by hand to fix them in place Fit magnets bracket Push the gate fully closed by hand Locate and install the magnet bracket so that the opener will stop at the desired close position when the close limit switch approaches it Push the gate fully open by hand Locate and install the magnet bracket so that the opener will stop at the desired open position when the open limit switch approaches it The higher magnet bracket must be installed at left side and lower magnet bracket must be installed at right side from the view inside of property Finally adjust the magnet to the proper position by moving the gate with the motor The magnet should be 39 59 away from the magnetic limit switch If it is too far away the switch will fail to work The distance between the magnet and the opener should be 1 2 12mm with the opener cover on Adjust the position of the magnet until the positions of the opening and closing meet the requirement Important Note Please note the two magnet brackets fixed plate are different one is higher and ano the other is lower Connecting of the control board A Warning Before making any electrical wire connection or and setting the control board make sure that the power switch is OFF 1 Mot
21. tall force of the gate operator Turn the potentiometer clockwise to increase the stall force Turn the potentiometer counter clockwise to decrease the stall force Control Board otentiometer A Potentiometer B 2051 Bg ECCETTO mum mm m UP COM DN 12 GND PHO 5 XB2 XB1 Test the reversing sensitivity For the sake of safety it is very important to test the reversing sensitivity as soon as the control board set is finished The reversing sensitivity adjustment is inverse correlation with stall force adjustment in potentiometer A and potentiometer B In other word the stall force level is higher the reversing sensitivity level is lower 14 Put an immobile object along the gate path and then operate the gate to strike it during the open and close cycles The gate must reverse as soon as object is struck with it If the gate doesn t reverse please increase the reversing sensitivity by turning the potentiometer in counter clockwise direction Turning the stall force potentiometer toward to MIN position to increase the reversing sensitivity Note 1 If the sensitivity setting is too higher the gate will stop or reverses very easy by itself while there is little obstruction or resistance such as strong wind or heavy snow sometimes Note 2 Always check the gate reversing function every each time of control board set or restart
22. user about the control systems provided and the manual opening operation in case of emergency Do not allow persons or children to remain in the automation operation area Keep radio control or other control devices out of children s reach in order to avoid unintentional automation activation The user must avoid any attempt to carry out work or repair on the automation system and always request the assistance of qualified personnel Anything which is not expressly provided for in the present instructions is not allowed Installation must be carried out using the safety devices and controls prescribed by the EN 12978 Standard Important Safety Instructions A WARNING To reduce the risk of injury or death 1 READ AND FOLLOW ALL INSTRUCTIONS 2 Never let children operate or play with gate controls Keep the remote control away from children 3 Always keep people and objects away from the gate NO PERSON SHOULD CROSS THE PATH OF THE MOVING GATE 4 Test the gate opener monthly The gate MUST reverse on contact with a rigid object or stop when an object activates the non contact sensors After adjusting the force or the limit of travel retest the gate opener Failure to adjust and retest the gate opener properly can increase the risk of injury or death 5 Use the emergency release only when the gate is not moving 6 KEEP GATES PROPERLY MAINTAINED Read the owner s manual Have a qualified service person make repairs to gate h
Download Pdf Manuals
Related Search
Related Contents
カタログ(PDF:2799KB) Liberté et déterminisme - Institut de pratiques philosophiques Planet Technology WGS3-2620 User's Manual Patton electronic 3054 Network Card User Manual Hairdryer Peavey Deuce User's Manual Manuale istruzioni Manual - EcoTech Marine Single Vacuum Installation Curtis FRW218B User's Manual Copyright © All rights reserved.