Home

manual de instalación installation manual manuel d

image

Contents

1. SPA DE USO PRIVADO SPA FOR PRIVATE USE SPA POUR UN USAGE PRIVE SPA FUR PRIVATE NUTZUNG SPA PER USO PRIVATO SPA PARA USO PRIVADO SPA VOOR PRIVE GEBRUIK f i j e IS eem dh a MANUAL DE INSTALACION INSTALLATION MANUAL MANUEL D INSTALLATION MONTAGENHANDBUCH MANUALE D INSTRUZIONI MANUAL DE INSTALACAO INSTALLATIEHANDLEIDING RELEASE 01 01 2011 ES FR DE IT PT 19 35 51 67 83 99 CONTENTS 1 General details 20 2 Safety warnings 21 2 1 General 21 2 2 Warnings in installation and assembly work 21 2 3 Warnings in maintenance work 21 3 Installation and assembly 22 3 1 Positioning and location of the Spa 22 3 2 Drainage of the Spa 23 3 3 Electrical connection 24 4 Start up 31 4 1 Filling the Spa 31 5 Troubleshooting 33 6 Declaration of Conformity 34 IMPORTANT This instructions manual contains fundamental information on the safety measures to be adopted when installing and starting up the spa It is therefore essential that both the Fitter and the User read these instructions before assembly and start up 1 GENERAL DETAILS This manual contains all the information needed to fully enjoy your SPA We recommend that you take some time to go over the points detailed below If you have any question or doubt on the operation or maintenance of this product please contact your fitter or local dealer They are specialists and their professional knowle
2. P a 57 Balboa E om Ih e O Zr gt h Three phase line wam 190 eG RUND woes OU 8 8 Fa Tha 250W AN ATTENTION Correct earthing is essential The earthing circuit of the building should always be in perfect condition to guarantee the safety of Spa users If you have any doubts on this ensure that the earthing circuit is checked by a duly qualified person The manufacturer will not be held responsible for possible damage caused by incorrect maintenance of the earthing circuit Fasten the earth cable yellow and green to the terminal on the outside of the control cabinet as shown in the following diagram wn ATTENTION 4 START UP ATTENTION Before start up read the following points carefully 4 1 FILLING THE SPA The Spa does not have a specific filling system It is recommended to use a manual filling system with a garden hose or similar Proceed as follows e Before starting filling the Spa locate the drain valve see Locating the drain valve and ensure that it is in the CLOSED position e Fill the Spa through the top with clean water to the level indicated on the label placed in the skimmer area water should cover the filter by at least 3 cm 4 1 1 FILLING PRIVATE OVERFLOW SPAS It is recommended to fill the spa manually using a garden hose or a similar system Proceed as follows Before filling the spa find the drainage valves and ensure they
3. Spa ensure that the packaging of the Spa is in perfect condition Contact your distributor immediately if the packaging is damaged 3 1 POSITIONING AND LOCATION OF THE SPA Position the Spa horizontally placing the whole base of the unit on a smooth flat and level surface capable of supporting the weight when used full of water plus the weight of the bathers The Spa cannot be placed on a curved surface or on blocks TIIIIIIIIIIIIIIIII EEEIEE 3 1 1 PORTABLE ADJUSTABLE SPAS Some spas come with a metal structure to facilitate their installation This structure has several points of support Before filling the spa these points of support should be adjusted to ensure they are all in contact with the ground Bat omma im m a ER nn s m u s s S Sessea s won m s a a WW e AV a m m m a m m m r m a Gs S s h q ici m s brn ma a b w bo P F 77 s m Pr EF ae E AE FFF 7 i DIG FIR Tb 7 Fi a E at F Fa Fa A Avoid placing the Spa where water could leak into the electrical equipment compartment and also protect the unit from direct contact with very damp areas ZZZZZZZZZZZZZ The side where the motors are located should be fully accessible In order to carry out maintenance tasks the location of the Spa should enable it to be moved so that all its sides can be easily accessed Outdoor installation If an outdoor location
4. are all closed except for the safety outlet which should always be open Fill the spa from above using clean water until the spa starts to overflow Fill the three pumps with at least 15 cm of water so that the filter pump does not take in air when working normally Connect the water supply to one of the tanks inlets Before opening the filter lid ensure that the 3 valves that regulate the filtration circuit are closed If they are open the spa would be emptied through the filter lt WATER SUPPLY SAFETY OUTLET The spa has a filling system that works using a ball cock The outlet of the ball cock must be connected to the mains supply at a constant water pressure When the spa loses water as a result of evaporation the system automatically fills the tanks The compensation tanks have a safety outlet for removing water WARNING THE COMPENSATION TANKS OF PRIVATE OVERFLOW SPAS HAVE A LIMITED CAPACITY THEY CAN HOLD 280 LITRES OF WATER EQUIVALENT TO 4 PARTIALLY SUBMERGED PEOPLE USERS SHOULD ENTER THE SPA ONE BY ONE AND SLOWLY TO ENABLE THE TANKS TO ABSORB THE DISPLACED WATER AND PREVENT WATER FROM FLOWING OUT OF THE SPA N WARNING During the filling process water should be prevented from entering electrical parts If seawater is used in the Spa the circuit components will quickly deteriorate Do not fill the Spa with hot water as this could trigger off the safety thermostat and damage equi
5. is chosen to place the Spa e Do not expose the Spa to sunlight when it is empty and without a protection cover Remember that prolonged exposure to sunlight may damage the surface of the Spa and its accessories Acrylic rapidly absorbs heat from the sunrays reaching very high temperatures which will damage the Spa Maximum absorption temperature is 60 C e It is recommended to place the Spa away from trees as falling leaves may block the filter e If the Spa is placed inside glass structures prevent sunrays shining directly on the Spa through the glass as the temperature could be excessively hot Indoor installation It is recommended to ensure drainage in the area of the Spa to prevent water from accumulating around it and to avoid dangerous access areas for bathers Remember that the operation of the Spa causes increased damp and therefore there must be a ventilation system to prevent damp from accumulating which could cause damage in the room where the Spa is located The use of a cover reduces heat loss and damp in the room The Spa should not be left empty and uncovered at room temperatures over 20 C or below 4 C 3 2 DRAINAGE OF THE SPA The Spa has a manual emptying system by gravity through a drainage valve of 3 4 The drainage valve should always be closed It should only be open when the Spa is emptied If necessary a drainage system can be installed to connect the Spa to the general drains of the house
6. 95 EN 60335 2 60 1991 A52 1994 FORSAKRAM OM OVERENSSTAMMELSE Ovans ende produkter 4 i verenst mmelse med Direktiv 89 336 CEE Elektromagnestik kompatibilitet Direktiv 73 23 CEE L gsp nning och med Europeisk Standard EN 60335 1 1995 EN 60335 2 60 1991 A52 1994 OVERENSSTEMMELESESERKL ERING Ovenstaende produkter oppfyller betingelsene elektromagnetiskdirektiv 89 336 EU lavpenningsdirektiv EU73 23 og Europeisk Standard EN 60335 1 1995 EN 60335 2 60 1991 A52 1994 OVERENSSTEMMELSESERK RING De ovenn vnte varer er i overensstemmelse med Direktiv 89 336 EU Elektromagnetisk forenelighed Direktiv 73 23 EU Lavsp nding og i overensstemmelse med den europ iske standard EN 60335 1 1995 EN 60335 2 60 1991 A52 1994 VAKUUTUS YHDENMUKAISUUDESTA Yll mainiut tuotteet ovat yhdenmukaisia direktiivin EU 89 336 Elektromagneettinen yhdenmuskaisuus direktiivin EU 73 23 Matalaj nnite sek eurooppalaisen standarinEN 60335 1 1995 EN 60335 2 60 1991 A52 1994 AHAQZH ZYMBATOTHTAZ Ta napana vo npot vta sivau gvugova us tnv Odnyia 89 336 EE H Azktpouayvnuknl Evu atotnta tnv Odnyia 73 23 EE Gounan Toon kov wetov Evponatk Kavoviou EN60335 1 1995 EN 60335 2 60 1991 A52 1994
7. EE Low Voltage and with the European Standard EN 60335 1 1995 EN 60335 2 60 1991 A52 1994 KONFORMIT TSERKL RUNG Die oben angef hrten Produkte entsprechen den Sicherheitsebestimmungen der Richtlinien der Elektromagnetischen Vertr glich 89 336 EG der Niederspannungs Richtlinien 73 23 EG un der europ ischen Vorrschrift EN60335 1 1995 EN60335 2 60 991 A52 1994 DECLARATION CONFORMITE Les produits mentionnes ci dessus sont conformes aux Directive Compatibilit Electromagnetique 89 336 CEE Directive Basse Tension 73 23 CEE et a la Norme Europ enne EN 60335 1 1995 EN 60335 2 60 1991 A52 1994 DICHIARAZIONE DI CONFOMITA prodotti su elencati sono conformi alle seguenti Directtiva 89 336 CEE Compatibilita elettromagnetica Directtiva 73 23 CEE Bassa Tensione e alla Norma Europea EN 60335 1 1995 EN 60335 2 60 1991 A52 1994 DECLARACAO DE CONFORMIDADE Os produtos acima mencionado estao conforme a Directiva 89 336 CEE Compatibilidade Electromagn tica Directiva 73 23 CEE Baixa tensao e a Norma Europeia EN 60335 1 1995 EN 60335 2 60 1991 A52 1994 NL PRODUKTEN SPAS CON MUEBLE S PRODUKTER SPAS IN WOOD N PRODUKTER CLADDING DK PRODUKTER SF TOUTTEET GR IIPIONTA CONFOMITEITSVERKLARING Bovenstaande produkten voldoen aan de veiligheidsvoorschriften van de Richtliin Electromagnetische compatibiliteit 89 336 EEG laagspannings richtlijn 73 23 EEG en aan de Europese norm EN 60335 1 19
8. In this case the steps 5 and 6 are not necessary Operation of the valve is 3 3 ELECTRICAL CONNECTION ATTENTION VERY IMPORTANT This equipment cannot be connected to a normal plug This equipment requires suitable electrical installation This should be done by a specialised fitter following local electrical safety regulations of each country The electrical input of the Spa should always be protected by a highly sensitive differential A30 mA differential is recommended Earthing connection is essential Use a suitable section cable bearing in mind the power of the Spa and distance to the control panel Always follow instructions given in the Safety Warnings chapter of this manual ATTENTION RISK OF ELECTRIC DISCHARGE The electrical supply should be switched off differential in the OFF position or disconnect the cable from the mains before carrying out any work Never try to access an electrical component unless you are qualified or are the Head of Maintenance Always use suitable personal protection equipment and tools when handling electrical equipment Never access electrical elements if you are wet particularly if you have wet feet Do not connect the electrical equipment differential in the ON position if the Spa is empty of water Follow these steps to connect the Spa 3 3 1 Locate the electrical panel of the Spa Locate the electrical control panel to do this open the side panel to access
9. as disconnected owing to overheating Water leaks out through the Jets are closed Venturi Jets are not properly installed The outer trim of the jet turns a Remove the jet Pull the outer trim about 2 cm Unscrew the jet turning anti clockwise Once it has been dismantled replace quarter to open and close the water flow If this trim makes a complete turn it is not properly the jet by screwing in a installed and the jet will have clockwise direction Press the to be removed and then placed louter trim back into place correctly Limited airflow in the Jets Venturis are closed Open the Venturis Reduced airflow Starter brushes of the motor are Change the pump worn The water does not reach the Probe is damaged Replace the temperature probe required temperature Check programmed temperature Programme the temperature Note In the section Diagnosis message of the control panel User Manual the diagnosis messages to solve possible breakdowns are indicated Pol Ind Cervera Avda Pla d Urgell 2 8 25200 Cervera Spain DECLARACION DE CONFORMIDAD Los productos arriba mencionados se hallan conformes a Directiva 89 336 CEE Compatibilidad Electromagn tica Directiva 73 23 CEE Baja Tensi n y la Norma Europea EN 60335 1 1995 EN 60335 2 60 1991 A52 1994 EVIDENCE OF CONFORMITY The products listed above are in compliance with Directive 89 336 CEE Electromagnetic Compatibility Directive 73 23 C
10. dge will help you to enjoy this product IMPORTANT The manufacturer reserves the right to change the design or specifications without prior notice and without entering into any obligation ATTENTION IMPORTANT Before carrying out any work on the Spa it should be switched off from the electrical supply differential in the OFF position or disconnect the mains cable This equipment cannot be connected to a normal plug This equipment requires suitable electrical installation This should be performed by a qualified person following the electrical safety standards of each country The electrical supply of the Spa should always be protected by a highly sensitive differential A 30 mA differential is recommended Earth connection is essential The earthing circuit of the building should always be in perfect condition to guarantee the safety of the Spa user If you have any doubts on this ensure that the earth circuit is checked by a qualified person The manufacturer is not responsible for possible damage caused by unsuitable maintenance of the earth circuit Do not connect the electrical equipment differential in the ON position if the Spa is empty of water Use a cable of a section suitable to the power of the Spa and the distance to the panel Always observe the instructions included in Safety Warnings chapter of this manual Never try to access an electrical component unless you are qualified or are the Head of Maintena
11. nce Never handle electrical elements with wet feet 2 SAFETY WARNINGS 2 1 GENERAL Avoid contact with electrical voltage Carefully follow current regulations regarding accident prevention Any modification on the equipment requires prior authorisation from the manufacturer Original spare parts and accessories authorised by the manufacturer guarantee greater safety The manufacturer of the equipment is exempt from all liability for damages caused by using non authorised spare parts or accessories During operation some parts of the equipment are at dangerous electrical voltage levels Work on each element or equipment can only be performed once it has been disconnected from the mains and having disconnected the start up devices The user should ensure that assembly and maintenance works are carried out by qualified and authorised persons and that they have carefully read the installation and service instructions Safety in the operation of the machine can only be guaranteed if installation and service instructions are followed The limits indicated in the electrical control panel cannot be exceeded under any circumstances Contact the Technical Service of the manufacturer or the local dealer of the manufacturer in the event of malfunction or a breakdown The Spa should be installed following current regulations applicable in each country particularly those referring to electrical safety e There is risk of flooding with thi
12. nstallation Manual Remember that the installation and any changes in the electric configuration must be carried out by qualified personnel following the current regulations in each country The manufacturer shall not be responsible for any damage caused by an improper installation or an installation performed by non qualified personnel Pay attention to the position of the maximum consumption switch The Spa will not operate properly if a cable not corresponding to the distance and power of the Spa is used and the electrical circuits may overheat which may cause an electrical accident Always use cable with the suitable section of maximum consumption In the event of doubt between two values always use the cable with the greater section To connect the supply to the electrical panel of the Spa locate the packing gland positioned at one end of the electrical panel Make sure that there is no electric current in the connection cable differential switch in the OFF position Take the cable to the Spa electrical panel Open the cover of the electrical cabinet insert the feed cable through the free side Attention the indicated blue cable is neutral and the brown cable indicates the line or phase Fasten the terminals as indicated in the following diagrams and the type of electrical supply Single line 1x16A or 1x32A Double line 2x16A s menne m Toes 5 3 D D F4 TOZA Z50V L2 N2 s m L1 M TT
13. pment and connections Once the Spa has been filled with water connect the electrical equipment by placing the differential switch in the On position See Electrical Connection Do not use the Spa without first carefully reading all the information detailed in the following points e Adjust water pH between 7 2 and 7 4 see Water maintenance e Add all required chemical products recommended in Water maintenance Maintenance Manual e Select the required temperature see Control Keyboard of the Spa Remember that if the water is cold it may take 24 hours to reach a temperature of 38 C e Before using the Spa check the pH values once again in case they have changed with the treatments indicated above 5 TROUBLESHOOTING Insufficient flow of filtered Filter is blocked by dirt Wash the filter water The massage pump of the Jets The cable of the digital control Connect the cable to the board does not work panel is disconnected from the Check that the pump is connected to the electric control panel Spa does not work board No electrical supply Differential is disconnected Connect the differential Connect the cable to the board The massage pump of the air The cable of the digital control Blower does not work panel is disconnected from the board Check that the pump is connected to the electric control No electrical supply panel Let it cool for about 3 hours and then start up the pump The pump h
14. s equipment and therefore it should be installed in an area prepared to collect and drain any water that may overflow both under and around the spa owing to its use or possible leaks in any of the circuits See the Guarantee e The equipment should be installed in a place which has been properly prepared and where all components of the Spa can be easily accessed The guarantee does not cover work needed to be carried out to install or replace the product See the Guarantee 2 2 WARNINGS IN INSTALLATION AND ASSEMBLY WORK While connecting the electrical cables to the equipment ensure that the layout inside the connection box is correct check that there are no pieces of cable remaining inside after it is closed and that it is properly earthed Take particular care to ensure that water cannot enter the pumps and live electrical parts 2 3 WARNINGS IN MAINTENANCE WORK e Before carrying out any electrical or mechanical maintenance work make sure that the machine is disconnected from the mains and that the start up devices are blocked e Do not handle the equipment with wet feet e In natural wood panelled Spas never perform maintenance work if the panels are damp because their dimensions might vary due to humidity absorption If this occurs it could be very difficult to assemble the panels Wood panels must be completely dry before performing any work on them 3 INSTALLATION AND ASSEMBLY Before installing and assembling the
15. ted Therefore the type of installation chosen will determine the amount of electricity consumed LOW AMP This setting disconnects the electric heater when any of the massage pumps are working which reduces electricity consumption This is the manufacturer s default configuration HIGH AMP This setting makes it possible for all spa components to work at the same time This type of installation consumes more power Changing from a low amp to a high amp setting is achieved thanks to the switches on the switchboard Table 1 of Hi Speed Pumps Blower Before Heat Disabled AZ MD OFF OFF 0 ON OFF 1 OFF ON 2 ON ON 3 IMPORTANT The Electric Specification Sheet attached to the manual indicates both the Low Amp and the High Amp power To determine the cable section of the electrical installation see the values indicated in this sheet and the following table Table of required sections distance and power kW required e k reguiee O O 2 1 2 5 2 8 3 2 3 5 4 4 5 3 6 2 7 0 7 9 8 8 Nominal section of the cable in mm aE e e ee mee 25 25 4 4 4 6 6 0 es s fs Tele For longer distances increase the cable section accordingly Some configurations may require installing 1 32A line 2 16A lines or even one three phase line 3 x 16A to cover the power required by the Spa The different configuration options of the electrical control panel are explained further on in this I
16. the electrical components The door is anchored by screws The control cabinet is the box that is in front of the electrical heater element To open it the four screws on the front cover must be unscrewed 3 3 2 Installation of the differential e The electrical installation should incorporate a high sensitive 2 pole differential in the general mains input panel the differential is not supplied with the Spa e ATTENTION It is essential that the owner of the Spa tests the differential switch at least once a month to check its good working order Check that the differential is in the OFF position Do not place the differential in the ON position until the Spa is filled with water 3 3 3 Connect the electrical control panel of the Spa to the differential switch Before carrying out any work on the Spa make sure it is disconnected from the mains differential switch in the OFF position or disconnect the cable from the mains Use a Suitable cable from the differential switch to the electric cabinet of the Spa depending on the location and applicable law The cable section will vary depending on the Spa model and the distance of the installation The required kW are indicated in the appendix Technical Specifications of the Spa The maximum power must be considered depending on the High Amp or Low Amp configuration High Amp Low Amp setting Power consumption can vary considerably depending on the spa setting selec