Home
SUNNY BOY 1200 / 1700 - Installation Guide
Contents
1. e Vertical installation or tilted backward by max 45 e The connection area must point downward e Never install the device with a forward tilt Installation Guide SB12_17 IEN104650 15 Mounting the Device SMA Solar Technology AG e Never install the device with a sideways tilt Do not install horizontally e Install at eye level in order to allow operating state to be read at all times e To ensure optimal operation the ambient temperature should be below 40 C e Do not expose the inverter to direct sunlight to avoid a power reduction due to excessive heating e Ina living area do not mount the unit on plasterboard walls or similar in order to avoid audible vibrations The inverter can make noises when in use which may be perceived as a nuisance in a living area e Observe the minimum clearances to walls other inverters or objects as shown in the diagram in order to ensure sufficient heat dissipation and sufficient space for the removal of the Electronic Solar Switch e Multiple inverters installed in areas with high ambient temperatures If necessary increase the clearances and make sure there is enough ventilation to ensure sufficient cooling of the inverters 16 SB12_17 IEN104650 Installation Guide SMA Solar Technology AG Mounting the Device 4 3 Mounting the Inverter with Wall Mounting Bracket CAUTION Risk of injury due to the heavy weight of the inverter e
2. Replacement varistors Set of thermally monitored varistors SB TV3 2 pcs including insertion tool Insertion tool for replacing the Insertion tool for varistor sets SB TVWZ varistors Positive grounding set Upgrade kit for the positive ESHV P NR connection to ground of the DC input Negative grounding set Upgrade kit for the negative ESHV N NR connection to ground of the DC input RS485 upgrade kit RS485 interface 485PB NR Radio upgrade kit Radio Piggy Back for upgrading an BEAMPB NR inverter for communication with Sunny Beam including antenna coaxial cable and PG cable gland metal Bluetooth upgrade kit Bluetooth interface BTPBINV NR SUNCLIX DC plug connector Field plug for conductor cross SUNCLIX FC6 SET sections of 2 5 mm 6 mm 68 B12_17 IEN104650 Installation Guide SMA Solar Technology AG Contact 13 Contact If you have technical problems concerning our products contact the SMA Serviceline We require the following information in order to provide you with the necessary assistance e Inverter type e Inverter serial number e Type and number of PV modules connected e Optional equipment e g communication devices e Blink code or display of inverter SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany www SMA de SMA Serviceline Inverters 49 561 9522 1499 Communication 49 561 9522 2499 Fax 49 561 9522 4699 E mail Serviceline SMA de Installation Guide SB
3. 92 e 90 88 86 i Al Sunny Boy 1200 pi 200 400 600 800 1000 1200 Pac W Peak efficiency Nesey 92 1 European efficiency NEU 90 9 64 B12_17 IEN104650 Installation Guide SMA Solar Technology AG 11 2 Sunny Boy 1700 DC Input Technical Data Maximum DC power at cos 1 Poc 1 850 W Maximum DC voltage VDC max 400 V MPP voltage range at 230 V AC Vpy 147 V 320 V DC nominal voltage VDC nom 180 V Minimum DC voltage at 230 V AC VDC min 139 V Start voltage adjustable VPV Start 180 V Maximum input current IPV max 12 6 A Number of MPP trackers 1 Maximum number of parallel strings 2 Voltage ripple of input voltage Vor lt 10 Internal consumption during operation lt 4W The maximum open circuit voltage which can occur at a cell temperature of 10 C may not exceed the maximum input voltage AC Output AC nominal power at 230 V AC 50 Hz PAC nom 1550W Maximum AC apparent power SAC max 1 700 VA Nominal AC current IAC nom 6 7A Maximum output current IAC max 8 6A Maximum fuse protection 16A Harmonic distortion of output current at Kiac lt 3 AC THD voltage lt 2 AC power gt 0 5 AC nominal power Nominal AC voltage VAC nom 220 V 230 V 240 V AC voltage range Vac 180V 265 V AC grid frequency FAC nom 50 Hz 60 Hz Operating range at AC grid frequency fac 50 Hz 45 5 Hz 54 5 Hz 60 Hz 55 5 Hz 64 5 Hz Power fac
4. e Ground yourself before touching a component 5 1 Overview of the Connection Area 5 1 1 Exterior View The following figure shows the assignment of the individual connection areas on the bottom of the inverter Object Description A DC connectors for connecting the PV strings Socket for connecting the Electronic Solar Switch ESS DC load disconnection unit Enclosure opening with sealing plugs for communication oja Socket for AC Connection Installation Guide SB12_17 IEN104650 19 Electrical Connection 5 1 2 Interior View The following illustration shows the various components and connection areas of the open inverter A B C D ll F Object Description A Varistors B Connection area and sockets for optional communication via RS485 or radio 0 Display D PE connection cable for the lid E Operating status LEDs F Socket for AC Connection G Tab for grounding the cable shield with RS485 communication H DC plug connectors I Electronic Solar Switch ESS socket 20 B12_17 IEN104650 Installation Guide SMA So
5. 1 Turn off the line circuit breaker 2 Remove the Electronic Solar Switch 3 Disconnect all the DC plug connectors 4 Check DC voltage Ifthe DC voltage exceeds the maximum input voltage check the plant design or contact the person who installed the PV generator Ifthe DC voltage is under the maximum input voltage reconnect the inverter to the PV generator as described in section 5 4 PV generator connection DC page 28 If the message occurs again disconnect the inverter again and contact the SMA Serviceline see section 13 Contact page 69 Watchdog Watchdog Srr Internal program run fault Corrective measures Ifthis fault occurs often contact the SMA Serviceline 9 3 Red LED is Glowing Continuously If the red LED of the status display is continuously on during operation there is either a ground fault in the PV generator or at least one of the varistors for the overvoltage protection is defective Procedure 1 Check for ground faults in the PV generator as described in section 9 3 1 Checking the PV Generator for a Ground Fault page 56 2 Ifthe red LED continues to glow check the varistors as described in section 9 3 2 Checking the Functioning of the Varistors page 58 Installation Guide B12_17 IEN104650 55 Failure Search SMA Solar Technology AG 9 3 1 Checking the PV Generator for a Ground Fault 1 Disconnect the inverter from both the DC
6. PV Inverter SUNNY BOY 1200 1700 Installation Guide SB12_17 IEN104650 IMEN SB11_17 Version 5 0 Cn SMA Solar Technology AG Table of Contents Table of Contents 1 1 1 1 2 1 3 1 4 2 2 1 2 2 2 3 2 3 1 2 3 2 3 1 3 2 4 1 4 2 4 3 5 1 5 1 1 5 1 2 5 2 5 2 1 5 2 2 5 2 3 Notes on this Manual 000 7 Scope sof Validifica been EL ao 7 TOIgeRGrovpia eo lee LN tha og oe ga cp oneness hats 7 Additional Ihfofmationi 3 spread od irta 7 Symbols Used setea ni ht aE E AEA ui 8 Solta lilla ea 9 Appropriate Usage sirazoanianizzparnani sole sni toria 9 Safety Precautions irreali aaa 11 Explanation of Symbols zare fai 12 Symbols on the Inverteri ccr taria et 12 Symbols on th e TypetLab el siest sritim eaer dee tun rioni aa aaa 13 Unpacking si aaa ai 14 Scopesol Delivery aiuti ri elia 14 Identifying the Inverter 14 Mounting the Device cece eee eee eens 15 Saleh is Ware elia are 15 Selecting the Mounting Location 15 Mounting the Inverter with Wall Mounting Bracket 17 Electrical Connection L LL 19 Overview of the Connection Area 19 Exterior View Loi a ei elia 19 Inte riot VieW 2 450 2a chele Bs BG heh ial Be e 20 Connection to the Public Grid AC 21 Conditions for the AC Connection 21 Connecting the Inverter to the Public Grid AC 23 Connecting additional grounding o asasena aeaaeae 26 Installation Guide
7. The capacitors in the inverter require 15 minutes to discharge e Wait 15 minutes before opening the inverter 7 Ensure that there is no voltage at the DC plugs at the inverter MI If there is a voltage present check the installation 8 Remove all screws from the enclosure lid and pull the lid forward smoothly 9 Remove the protective conductor PE connection from the lid by loosening the locking device of the PE connection on the lid M The inverter is now open and is not live 46 B12_17 IEN104650 Installation Guide SMA Solar Technology AG Opening and Closing 7 3 Closing the Inverter 1 Reconnectthe protective conductor PE connection to the enclosure lid 2 Secure the enclosure lid of the inverter by evenly tightening the 4 lid screws 3 Check the DC plug connector for correct polarity and connect it To release the plug connectors see section 7 2 Opening the Inverter page 44 4 Close all unnecessary DC inputs as described in section 5 4 4 Connecting the PV Generator DC page 32 to seal the inverter 5 Pull out the AC plug Installation Guide SB12_17 IEN104650 47 Opening and Closing SMA Solar Technology AG 6 Check the Electronic Solar Switch for wear as described in section 8 1 Checking the Electronic Solar Switch for Wear page 49 and reattach it firmly i a Cc O NOTICE 5 Manipulating the connector
8. guidelines 9 The inverter has a transformer Direct Current DC Alternating current AC Protection rating IP65 SA A The inverter is protected against penetration by dust particles and water jets from any angle RAL quality mark for solar products COrezEcHEN The inverter complies with the requirements of the German Institute for Quality Assurance and Labeling Solar Installation Guide SB12_17 IEN104650 13 Unpacking SMA Solar Technology AG 3 Unpacking 3 1 Scope of Delivery Check the delivery for completeness and for any visible external damage Contact your dealer if anything is damaged or missing G H K L M N Object Quantity Description A Sunny Boy B Wall mounting bracket C 1 Electronic Solar Switch ESS D 4 DC plug connectors 2 x positive 2 x negative E 4 Sealing plugs for DC plug connectors F 1 Protective cap for AC socket on inverter G 1 AC connection socket socket unit threaded sleeve pressure screw PG13 5 sealing ring PG13 5 fastening case PG13 5 cable gland PG16 M6x12 cylinder head screw and locking washer Jumper Installation guide User manual Set of documents with explanations and certificates Z z Al z Supplementary sheet with inverter factory settings 3 2 Identifying the Inverter You can identify the inverter by the type label The type label is
9. surroundings of the inverter The DC current flow may not be interrupted via adaptors e Observe the procedure for disconnecting the inverter as described in section 7 2 Opening the Inverter page 44 e Requirements for the PV modules of the connected strings Same type Same number Identical alignment Identical tilt e The connecting cables from the PV modules must be fitted with plug connectors You will find the necessary DC plug connector for DC connection in the delivery e The following limiting values at the DC input of the inverter may not be exceeded Inverter Maximum input voltage Maximum input current SB 1200 400 V DC 12 6 A DC SB 1700 400 V DC 12 6 A DC DANGER Risk of lethal electric shock or fire The maximum possible input current per string is limited by the plug connectors used If the plug connector is overloaded an electric arc may occur and there is a fire risk e Ensure that the input current for each string does not exceed the maximum flow current of the plug connectors used 28 SB12_17 IEN104650 Installation Guide SMA Solar Technology AG Electrical Connection 5 4 2 Assembling the DC Plug Connector In order to connect to the inverter all connecting cables of the PV modules must be equipped with the DC plug connectors provided To assemble the DC plug connectors proceed as detailed below Ensure the plug connectors have the correct polarity The D
10. Glowing Continuously oaoa anana 55 Checking the PV Generator for a Ground Fault 56 Checking the Functioning of the Varistors LL 58 DecOMMISSIONING 5 siii sai erba 60 Dismantling the Inverter p terra 60 Packing the Inverter onon ananunua naaa 61 Sioring tie vertere laine 61 Disposing of the Inverter pura sini pdl ii ola 61 Technical Deto ssusis elisa 62 Sunny Boy 1200 sierra ea 62 Sunny Boy 1700 A ins rAirsrioniolpA Ne Gwe eh sky hs 65 Accessories n ina ONY SDE RG ee 68 Contact carrara 69 Installation Guide SB12_17 IEN104650 5 Table of Contents SMA Solar Technology AG 6 SB12_17 IEN104650 Installation Guide SMA Solar Technology AG Notes on this Manual 1 Noteson this Manual 1 1 Scope of Validity This manual describes the assembly installation commissioning and maintenance of the following SMA inverters e Sunny Boy 1200 SB 1200 e Sunny Boy 1700 SB 1700 Store this manual where it can be accessed at all times 1 2 Target Group This manual is for qualified personnel The tasks described in this manual may only be performed by qualified personnel 1 3 Additional Information You will find further information on special topics such as designing a line circuit breaker or the description of the operating parameters in the download area at www SMA de en Refer to the user manual for detailed information on operating the inverter Installation Guide SB12_17 IEN104650 T N
11. M You have found no ground fault It is likely that one of the thermally monitored varistors is defective e Check the varistors as described in section 9 3 2 Checking the Functioning of the Varistors page 58 Location of the ground fault The approximate position of the ground fault can be determined from the ratio of the measured voltages between the plus pole against ground potential and the minus pole against ground potential PE Example V 200 V V 300V 7 O 100V 100V 7 100 V 100 V 100 V I O a In this case the ground fault is between the second and third PV module M The ground fault check is finished Installation Guide SB12_17 IEN104650 57 Failure Search SMA Solar Technology AG 9 3 2 Checking the Functioning of the Varistors Varistors are wear parts Their functional efficiency diminishes with age or following repeated responses as a result of overvoltages It is therefore possible that one of the thermally monitored varistors has lost its protective function and thus the red LED is lit r i i Position of Varistors You can determine the position of the varistors using the illustration below Observe the following allocation of the terminals Terminal A outer terminal varistor connection with loop crimp e Terminal B middle terminal e Terminal C outer terminal varistor connection without loop crimp Check the func
12. Take the inverter s weight of approx 25 kg into account for mounting e When mounting the bracket use fastening material suitable for the material 1 Use the wall mounting bracket as a drilling template and mark the positions of the drill holes 440 mm i 180 mm 167 mm 2 Attach the wall mounting bracket to the wall using appropriate screws and washers Installation Guide SB12_17 IEN104650 Mounting the Device Use the upper mounting clips to fit the inverter in the wall mounting bracket so that it cannot be pushed out of the wall mounting bracket from the side If a second grounding conductor is required in the country of installation you need to ground the inverter and secure it against being lifted out of place as described in section 5 2 3 Connecting additional grounding page 26 If a second grounding conductor is not required secure the inverter against being lifted out of place using the enclosed M6x12 screw 6 Check to ensure the inverter is firmly fastened MI The inverter is now mounted to the wall B12_17 IEN104650 SMA Solar Technology AG Installation Guide SMA Solar Technology AG Electrical Connection 5 Electrical Connection NOTICE E Electrostatic discharges can damage the inverter Internal components of the inverter can be irreparably damaged by static discharge
13. and AC connections as described in section 7 2 Opening the Inverter page 44 DANGER A Risk of lethal electric shock e Only touch the cables of the PV generator on their insulation e Do not connect strings with ground faults to the inverter i NOTICE o Excessive voltages can destroy the measuring device e Only use measuring devices with a DC input voltage range up to at least 1 000 V 2 Measure the voltages between the positive pole of the strings and the ground potential PE PE le T 3 Measure the voltages between the minus pole of the strings and the ground potential PE n 4 Measure the voltages between the plus pole and the minus pole of each string 4 ey If the voltages measured are stable and the total of the voltages from the plus pole against ground potential and the minus pole against ground potential of a string roughly corresponds to the voltage between the plus pole and minus pole then there is a ground fault 56 B12_17 IEN104650 Installation Guide SMA Solar Technology AG Failure Search Result Action M You have found a ground fault e The installer of the PV generator must remedy the ground fault in the affected string You can determine the location of the ground fault as described below Do not reconnect the faulty string e Close the inverter and commission it as described in section 6 1 Commissioning the Inverter page 37
14. discuss the changes to these parameters with your utility operator A detailed description of the operating parameter for the inverter is available in the download area at www SMA de en in the category Technical Description of the respective inverter 5 6 1 Setting the Installation Country Using the Default parameter you can set the installation country and or the grid connection standard valid for the country via a communication device e g Sunny WebBox or a PC with appropriate software e g Sunny Data Control or Sunny Explorer This however is only required if the inverter was originally ordered for another country You can see the standard to which the inverter was set upon delivery from the type label and the supplementary document provided with the factory settings Installation Guide SB12_17 IEN104650 35 Electrical Connection SMA Solar Technology AG 5 6 2 Setting Stand alone Grid Operation To operate the inverter in a Sunny Island system you must set the inverter via the Default parameter to off grid OFF Grid operation You have several possibilities to set the inverter to stand alone grid operation Setting via Sunny WebBox or e Setting via Sunny Data Control or Sunny Explorer DANGER Danger to life due to high voltages in the event of outage of the power distribution grid If you set the inverter to stand alone grid operation it does not fulfill any country specific standards and regulations Therefore
15. if there is an outage of the power distribution grid there is a danger of back feed e Never operate the inverter directly on the power distribution grid when set to stand alone grid operation 36 B12_17 IEN104650 Installation Guide SMA Solar Technology AG Commissioning 6 Commissioning 6 1 Commissioning the Inverter 1 Check the following requirements before commissioning The inverter is firmly fastened Correct connection of the AC cable grid Full connection of the DC cables PV strings DC inputs that are not needed are closed with the corresponding DC plug connectors and sealing plugs The enclosure lid is securely screwed in place The Electronic Solar Switch ESS is securely plugged The line circuit breaker is laid out correctly 2 Switch on the line circuit breaker M or M or M Green LED glows commissioning has been successful Green LED flashes when there is insufficient irradiation network connection conditions have not yet been reached Wait for sufficient irradiation The red or yellow LED is glowing or flashing there has been an error Proceed to step 3 gt Green LED Operation w Red LED Ground fault or varistor defective Yellow LED Disturbance Self test in accordance with DK 5940 Ed 2 2 for initial commissioning applies to Italy only The Italian DK 5940 standard requires that an inverter can first operate on the power distribut
16. o o on the inverter Remove the protective cap beforehand as required 17 Turn the threaded ring of the AC connection socket tightly onto the AC socket on the inverter The a threaded ring serves to seal and relieve strain on the AC connection socket MI The AC cable is now connected to the inverter DANGER Danger to life due to high voltages in the inverter e Do not switch on the line circuit breaker until the PV generator has been connected and the inverter is securely closed Installation Guide B12_17 IEN104650 25 Electrical Connection SMA Solar Technology AG 5 2 3 Connecting additional grounding If a second grounding conductor additional grounding or potential equalization is required you may also ground the inverter on the enclosure Additional grounding overview A F Object Description A M6x12 cylinder head screw included in the scope of delivery B Washer C Terminal lug M6 with grounding conductor D Locking washer included in scope of delivery E Metal shackle on the underside of the enclosure F Wall bracket of the inverter Procedure 1 Fit the washer terminal lug with grounding conductor and locking washer onto the cylinder head screw The toothing of the locking washer must face toward the metal shackle ML 2 Insert the cylinder head screw into the metal shackle on the underside of the enclosure and screw into the wall bracket Tight
17. on the plastic shape B Result Action MI The metal tongues in the Electronic Solar 1 Securely attach the Electronic Solar Switch Switch are undamaged and not discolored handle A 2 Commission the inverter as described in or section 6 Commissioning page 37 MI The plastic in the Electronic Solar Switch is undamaged B Installation Guide SB12_17 IEN104650 49 Maintenance and Cleaning SMA Solar Technology AG Result MI The metal tongues in the Electronic Solar Switch have a brown discoloration or are burned through A or MI The plastic in the Electronic Solar Switch shows thermal deformation B Action The Electronic Solar Switch can no longer reliably disconnect the DC side 1 Replace the Electronic Solar Switch handle before attaching it again for the order number see section 12 Accessories page 68 2 Commission the inverter as described in section 6 Commissioning page 37 50 B12_17 IEN104650 Installation Guide SMA Solar Technology AG 9 Failure Search Failure Search If the inverter displays blink codes or error messages other than those described in the following section contact the SMA Serviceline In the user manual provided you will also find a description of the display messages during operation the status messages and measuring channels Do not try to carry out repairs other than those described here Instead use the
18. 12_17 IEN104650 69 SMA Solar Technology AG Legal Restrictions The information contained in this document is the property of SMA Solar Technology AG Publishing its content either partially or in full requires the written permission of SMA Solar Technology AG Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission Exclusion of liability The general terms and conditions of delivery of SMA Solar Technology AG shall apply The content of these documents is continually checked and amended where necessary However discrepancies cannot be excluded No guarantee is made for the completeness of these documents The latest version is available online at www SMA de or from the usual sales channels Guarantee or liability claims for damages of any kind are excluded if they are caused by one or more of the following e Damages during transportation Improper or inappropriate use of the product e Operating the product in an unintended environment e Operating the product whilst ignoring relevant statutory safety regulations in the deployment location e Ignoring safety warnings and instructions contained in all documents relevant to the product e Operating the product under incorrect safety or protection conditions Altering the product or supplied software without authority The product malfunctions due to operating attached or neighboring d
19. 3 5 e Push the sealing ring into the fastening case e Lead the pressure screw PG13 5 and the fastening case including the sealing ring over the AC cable e Lead threaded sleeve over the AC cable PG16 e Pass the cable gland PG16 over the AC cable e Lead threaded sleeve over the AC cable Insert the protective earth PE green yellow in the screw terminal with the earth sign on the socket element and tighten the screw Insert the neutral conductor N blue in the screw terminal 1 on the socket and tighten the screw Place phase L brown or black into screw terminal 2 on the socket insert and tighten the screw Terminal 3 on the socket element remains unused Make sure the wires are securely connected SB12_17 IEN104650 Installation Guide SMA Solar Technology AG Electrical Connection 13 Screw the threaded sleeve onto the socket element 14 Tighten the pressure screw or cable gland tightly onto the threaded sleeve Size used Procedure PG13 5 The fastening case along with the sealing ring is pressed into the threaded sleeve and can no longer be seen PG16 e Retighten the lock nut of the cable gland MI The AC connection socket has been screwed together 15 If the AC connection socket is not immediately connected to the inverter close the AC socket on the inverter with the protective cap provided 16 Insert the AC connection socket into the AC socket
20. 50178 1998 04 transport type E class 2K3 Features Topology LF transformer General data Protection rating according to DIN EN 60529 IP65 Protection class Noise emission typical lt 41 dB A Protective equipment All pole DC switch disconnector Electronic Solar Switch DC plug system SUNCLIX DC overvoltage protection Thermally monitored varistors Personal protection R gt 1MQ Insulation monitoring Pole confusion protection Short circuit diode AC short circuit protection Current control All pole AC disconnection unit Automatic disconnection device SMA Grid Guard 2 1 double design Communication Interfaces Bluetooth Wireless Technology Optional Radio Optional RS485 galvanically isolated Optional Installation Guide B12_17 IEN104650 63 Technical Data Electronic Solar Switch SMA Solar Technology AG Electrical service life in the event of a short circuit A minimum of 50 switching operations with a nominal current of 35 A Maximum switching current 35 A Maximum switching voltage 800 V Maximum PV power 12 kw Protection rating when plugged IP65 Protection rating when unplugged IP21 Efficiency 98 92 Vpy 110 VDC 5 Vpy 200 V DC 96 sega Vpy 320 V DC e 88 94 se
21. C plug connectors are marked with and Cable requirements e Use a PVI cable Procedure 1 Insert stripped cable into the plug up to the limit 2 Press the clamping clip downward until you hear an audible click lt 3 Ensure the cable is correctly in place Result Action M If the conductors are visible in the hollow e Proceed to step 4 cavity of the clamp the cable is in the correct position Installation Guide SB12_17 IEN104650 29 Electrical Connection SMA Solar Technology AG Result M If the conductors are not visible in the hollow cavity of the clamp the cable is not in the correct position Action Declamp the clamping clip Use a screwdriver with a width of 3 5 mm e Remove cable and start again from step 1 4 Push the threaded joint to the thread and screw into place with a torque of 2 Nm M The DC plug connectors are now assembled and can be connected to the inverters as described in section 5 4 4 Connecting the PV Generator DC page 32 30 B12_17 IEN104650 Installation Guide SMA Solar Technology AG Electrical Connection 5 4 3 Opening the DC Plug Connector 1 Screw the threaded joint off To release the plug connector slot a screw driver into the side catch mechanism and lever out Use a lt screwdriver with a width of 3 5 mm Sy Vp uno JA PEL Carefully pull the DC plug connector a
22. Failure Search page 51 You can operate the display by tapping it e 1 tap the backlight is switched on or the display switches to the next screen e 2 taps in quick succession the inverter shows the display messages from the initialization phase again see section 6 2 Display Messages during Initialization page 38 Electronic Solar Switch ESS DC load disconnection unit When the Electronic Solar Switch is plugged in the DC circuit is closed e To interrupt the DC circuit and disconnect the inverter securely under load you have to first pull out the Electronic Solar Switch and then remove all DC plug connectors as described in section 7 2 Opening the Inverter page 44 12 SB12_17 IEN104650 Installation Guide SMA Solar Technology AG Safety 2 3 2 Symbols on the Type Label Symbol Explanation Beware of dangerous electrical voltage The inverter operates at high voltages All work on the inverter must be A carried out by qualified personnel only Beware of hot surface The inverter can become hot during operation Avoid contact during operation Observe all documentation that accompanies the inverter The inverter must not be disposed of with the household waste For more X information on disposal see section 10 4 Disposing of the Inverter Rina page 61 CE mark The inverter complies with the requirements of the applicable EC
23. SB12_17 IEN104650 3 Table of Contents SMA Solar Technology AG 5 3 5 4 5 4 1 5 4 2 5 4 3 5 4 4 5 5 5 6 5 6 1 5 6 2 6 1 6 2 6 3 6 3 1 6 3 2 7 1 7 2 7 3 8 1 9 1 9 2 Setting the Display Language nonan nnana onana 27 PV generator connection DC 28 Conditions for the DC Connection 28 Assembling the DC Plug Connector LL 29 Opening the DC Plug Connector 31 Connecting the PV Generator DC LL 32 Communication Aa lita fiala 35 Setting the Grid and Country Parameters 35 Setting the Installation Country LL 35 Setting Stand alone Grid Operation 36 Commissioningi nea 37 Commissioning the Inverter 0000000 eee eee eee 37 Display Messages during Initialization 38 Self Test in accordance with DK 5940 Ed 2 2 lappliestollalyiony usgoostenppaacen ita 39 Starting the Self Test by Tapping 39 Completion of the Self Test LL 39 Opening and Closing 0000 44 SCOPARE SENO EE NEO 44 Opening the Iiyerte rsa resterete 44 Closing the Inverter n on nananana 47 Maintenance and Cleaning 49 Checking the Electronic Solar Switch for Wear 49 Eailure S arch israele peau vas ements 51 LED Codes asini 51 Error Messages ilaele aaa 52 SB12_17 IEN104650 Installation Guide SMA Solar Technology AG Table of Contents 9 3 9 3 1 9 3 2 10 10 1 10 2 10 3 10 4 11 11 1 11 2 12 13 Red LED is
24. SMA Solar Technology AG 24 hour replacement service the inverter will be ready for dispatch within 24 hours and sent to a forwarding agency and repair service 9 1 LED Codes Green Glows continuously Red Is not glowing Yellow Is not glowing Status OK feeding operation Glows continuously Is not glowing Ground fault or varistor defective Glows continuously OK initialization Flashes quickly 3 x per second Is not glowing Is not glowing OK stop Glows continuously Is not glowing Ground fault or varistor defective Flashes slowly 1 x per second Is not glowing Is not glowing OK waiting grid monitoring Glows continuously Is not glowing Ground fault or varistor defective Briefly goes out Approx 1x per second Is not glowing Is not glowing OK derating Glows continuously Is not glowing Ground fault or varistor defective Is not glowing Is not glowing Is not glowing OK nighttime deactivation Glowing flashing Disturbance Glows continuously Is not glowing Ground fault or varistor defective Glowing flashing Ground fault or varistor defective and disturbance Installation Guide B12_17 IEN104650 51 Failure Search SMA Solar Technology AG 9 2 Error Messages When a disturbance occurs the inverter generates a message which depends on the operating mode
25. an mini i the display of the inverter Hi ii of po erat a EEE int The voltage limit is increased successively until the shut down threshold is achieved and the inverter disconnects from the grid Once the inverter has disconnected from the grid the display successively shows the following values one after the other Disconnection value Uslore di soglia Corie e Calibration value e Reaction time Tempo lrrberweria e Present grid voltage Installation Guide SB12_17 IEN104650 41 Commissioning SMA Solar Technology AG Maximum Frequency In the third step the inverter tests the maximum frequency During the test sequence the frequency limit applied is Autotest shown in the display of the inverter Fac mami aa SGHs The frequency limit is reduced successively until the shut down threshold is achieved and the inverter disconnects from the grid Once the inverter has disconnected from the grid the display successively shows the following values one after the other e Disconnection value Valore di soglia On 49 95H e Calibration value Ual taratura GE 9HE e Reaction time Teneo intervento ke mt i FE n 3 e Present grid frequency Fresusngza pela Ual eff aes AHE 42 SB12_17 IEN104650 Installation Guide SMA Solar Technology AG Commissioning Minimum Frequency In the last step the inverter tests the minimum frequency During the test sequence the frequency limit app
26. and the type of the detected disturbance Message IPV Overvoltage IDISCONNECT DC Description and corrective measure Overvoltage at DC input Overvoltage can destroy the inverter Corrective measures Disconnect the inverter from the grid immediately 1 Turn off the line circuit breaker 2 Remove the Electronic Solar Switch 3 Disconnect all the DC plug connectors 4 Check DC voltage Ifthe DC voltage exceeds the maximum input voltage check the plant design or contact the person who installed the PV generator Ifthe DC voltage is under the maximum input voltage reconnect the inverter to the PV generator as described in section 5 4 PV generator connection DC page 28 If the message occurs again disconnect the inverter again and contact the SMA Serviceline see section 13 Contact page 69 ACVtgRPro The 10 minute average grid voltage is no longer within the permissible range This can have the following causes e The grid voltage at the connection point is too high e The grid impedance at the connection point is too high The inverter disconnects to assure compliance with the voltage quality of the grid Corrective measures Check the grid voltage at the connection point of the inverter If due to the local grid conditions the grid voltage is 253 V or more ask the utility operator whether the voltage at the feed in point can be adjusted or whether it would agree to an a
27. come void e Do not connect strings with an open circuit voltage greater than the maximum input voltage of the inverter e Check the system design 32 B12_17 IEN104650 Installation Guide SMA Solar Technology AG Electrical Connection 4 Check the strings for ground faults as described in section 9 3 1 Checking the PV Generator for a Ground Fault page 56 DANGER Risk of lethal electric shock Do not connect strings with ground faults e First rectify the ground fault in the respective string g P g 5 Check the DC plug connector for correct polarity and connect it To release the plug connectors see section 7 2 Opening the Inverter page 44 6 To create the sealing on the inverter all the DC inputs that are not needed must be closed as follows Insert the sealing plugs provided into the DC a plug connectors that are not required Do not insert the sealing plus into the DC inputs Pd Pd on the inverter Insert the DC plug connectors with sealing plugs into the corresponding DC inputs on the inverter Installation Guide SB12_17 IEN104650 33 SMA Solar Technology AG Electrical Connection 7 Check the Electronic Solar Switch for wear as described in section 8 1 Checking the Electronic Solar Switch for Wear page 49 and reattach it firmly gt Manipulating the connector in the handle can damage t
28. en the cylinder head screw using a torque of 6 Nm 3 Check that the contact between the grounding conductor and the enclosure is in accordance with the regulations valid for the country of installation 26 SB12_17 IEN104650 Installation Guide SMA Solar Technology AG 5 3 Setting the Display Language Electrical Connection You can set the language of the display using the switches on the underside of the display assembly inside the inverter Procedure 1 Open the inverter as described in section 7 2 Opening the Inverter page 44 2 Set the switches for the required language as shown below 2 Language Switch 2 Switch S1 German B B aos English B A I French A B em Spanish A A B_ A B For type SB 1200 IT 1700 IT inverters the following switch settings apply for firmware version 3 06 and higher Language Switch 2 Switch S1 German B B Italian B A French A B English A A 3 Close the inverter as described in section 7 3 Closing the Inverter page 47 M The display language has now been set Installation Guide B12_17 IEN104650 27 Electrical Connection SMA Solar Technology AG 5 4 PV generator connection DC 5 4 1 Conditions for the DC Connection z Use of Adaptors I Adaptors branch connectors must not be visible or freely accessible in the immediate
29. evices beyond statutory limit values In case of unforeseen calamity or force majeure The use of supplied software produced by SMA Solar Technology AG is subject to the following conditions SMA Solar Technology AG rejects any liability for direct or indirect damages arising from the use of software developed by SMA Solar Technology AG This also applies to the provision or non provision of support activities Supplied software not developed by SMA Solar Technology AG is subject to the respective licensing and liability agreements of the manufacturer SMA Factory Warranty The current guarantee conditions come enclosed with your device These are also available online at www SMA de and can be downloaded or are available on paper from the usual sales channels if required Trademarks All trademarks are recognized even if these are not marked separately Missing designations do not mean that a product or brand is not a registered trademark The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of such marks by SMA Solar Technology AG is under license SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Tel 49 561 9522 0 Fax 49 561 9522 100 www SMA de E Mail info SMA de 2004 to 2010 SMA Solar Technology AG All rights reserved Installation Guide SB12_17 IEN104650 71 SMA Solar Technology AG
30. g operation NOTICE A N Dust and water in the Sunny Boy can damage the inverter A Once the Electronic Solar Switch has been pulled out the inverter only provides protection rating IP21 The inverter is then no longer protected against water and dust In order that the protection rating IP65 is also provided during a temporary decommissioning proceed as follows Release and disconnect all DC connectors Open all DC connectors and remove the cables e Close all DC inputs with the corresponding DC connectors and the sealing plug provided e Securely attach the Electronic Solar Switch again Grounding the PV Generator Comply with the local requirements for grounding the modules and the PV generator SMA Solar Technology AG recommends connecting the generator frame and other electricity conducting surfaces so that there is continuous conduction and to ground them in order to achieve maximum protection of the system and personnel Installation Guide B12_17 IEN104650 11 Safety SMA Solar Technology AG 2 3 Explanation of Symbols This chapter contains an explanation of all symbols found on the inverter and type label 2 3 1 Symbols on the Inverter Symbol Explanation Operation display Indicates the operation condition of the inverter Ground fault or varistor defective Read section 9 3 Red LED is Glowing Continuously page 55 Disturbance or fault Read section 9
31. g the PV Generator for a Ground Fault page 56 ROM The inverter s firmware is faulty Corrective measures Ifthis fault occurs often contact the SMA Serviceline Shutdown Temporary inverter fault Corrective measures e Contact the SMA Serviceline Vac Bfr The grid voltage is no longer within the permissible range Bfr or Srr is Vacsir an internal message of no relevance for the user This code can be caused by any of the following conditions e Grid disconnected line circuit breaker fuse e AC cable is broken or e AC cable is highly resistive For safety reasons the inverter disconnects itself from the grid Corrective measures e Check the grid current and grid connection on the inverter e Ifthe grid voltage lies outside the acceptable range because of local grid conditions ask the utility provider if the voltage can be adjusted at the feed in point or if it would agree to changes in the values of the monitored operational limits operating parameters Uac Min and Uac Max e If the grid frequency is within the tolerable range yet Vac Bfr or Vac Srr faults are still being displayed please contact the SMA Serviceline 54 SB12_17 IEN104650 Installation Guide SMA Solar Technology AG Failure Search Message VpvMax Vpv Max Description and corrective measure Overvoltage at DC input The inverter may be damaged Corrective measures Immediately disconnect the inverter from the grid
32. he Electronic Solar Switch The connector within the handle must remain movable in order to ensure proper contact Tightening the screw voids all warranty claims and creates a fire risk A NOTICE e Do not tighten the connector screw in the Electronic Solar Switch handle J N NOTICE The Electronic Solar Switch can be damaged if it is inserted incorrectly If not plugged correctly the Electronic Solar Switch can be damaged by high voltages e Connect the holder firmly on to the socket of the Electronic Solar Switch e Check that the handle is securely in place MI The PV generator is now connected 34 SB12_17 IEN104650 Installation Guide SMA Solar Technology AG Electrical Connection 5 5 Communication The inverter is equipped with a slot for communication interfaces in order to communicate with special data acquisition devices e g Sunny WebBox or a PC with corresponding software e g Sunny Data Control or Sunny Explorer Refer to the communication interface manual for a detailed wiring diagram and a description of the mounting 5 6 Setting the Grid and Country Parameters Changing Grid Relevant and Country Parameters e 1 To change grid relevant parameters you need a personal access code the so called SMA Grid Guard Code The application form for the personal access code is located in the download area at www SMA de en in the Certificate category for each inverter Ensure that you
33. in the handle can damage the Electronic Solar Switch The connector within the handle must remain movable in order to ensure proper contact Tightening the screw voids all warranty claims and creates a fire risk e Do not tighten the connector screw in the Electronic Solar Switch handle NOTICE The Electronic Solar Switch can be damaged if it is inserted incorrectly If not plugged correctly the Electronic Solar Switch can be damaged by high voltages e Connect the holder firmly on to the socket of the Electronic Solar Switch e Check that the handle is securely in place 7 Switch on the line circuit breaker 8 Check whether the display and the LEDs indicate normal operating mode see section 6 Commissioning page 37 M The inverter is now closed and in operation 48 SB12_17 IEN104650 Installation Guide SMA Solar Technology AG Maintenance and Cleaning 8 Maintenance and Cleaning Check for proper inverter operation at regular intervals Impurities such as dust or pollen can cause heat accumulation that can lead to yield losses Also check the inverters and the cables for visible external damage Undertake repairs if necessary 8 1 Checking the Electronic Solar Switch for Wear Check the Electronic Solar Switch for wear before plugging it in Depending on the shape of the Electronic Solar Switch you can estimate the wear on either the metal tongues shape A or
34. inal packaging If it is no longer available you can also use an equivalent box The box must be capable of being closed completely and made to support both the weight and the size of the inverter 10 3 Storing the Inverter Store the inverter in a dry place where ambient temperatures are always between 25 C and 60 C 10 4 Disposing of the Inverter Dispose of the inverter at the end of its service life in accordance with the disposal regulations for electronic waste which apply at the installation site at that time Alternatively send it back to SMA Solar Technology AG with shipping paid by sender and labeled ZUR ENTSORGUNG for disposal see section 13 Contact page 69 Installation Guide SB12_17 IEN104650 61 Technical Data SMA Solar Technology AG 11 Technical Data 11 1 Sunny Boy 1200 DC Input Maximum DC power at cos 1 Poc 1320 W Maximum DC voltage VDC max 400 V MPP voltage range at 230 V AC Vpy 100 V 320 V DC nominal voltage VDC nom 120 V Minimum DC voltage at 230 V AC VDC min 100 V Start voltage adjustable VPV Start 120 V Maximum input current Ipy max 12 6 A Number of MPP trackers 1 Maximum number of parallel strings 2 Voltage ripple of input voltage Vor lt 10 Internal consumption during operation lt 4W The maximum open circuit voltage which can occur at a cell temperature of 10 C
35. ion grid when the disconnection times for overvoltage undervoltage minimum frequency and maximum frequency have been checked Restart the self test as described in the following section 6 3 Self Test in accordance with DK 5940 Ed 2 2 applies to Italy only page 39 The test takes approx 8 minutes 3 Read section 9 Failure Search page 51 and if necessary eliminate the fault or disturbance Installation Guide SB12_17 IEN104650 37 Commissioning 6 2 Display Messages during Initialization After startup of the inverter the display shows the inverter type After 5 seconds or when you tap again on the enclosure cover the firmware version of the internal processors is displayed After a further 5 seconds or when you tap again the configured country standard is displayed example GER VDE0126 1 1 f i Show display messages again operation tap twice on the enclosure cover 38 B12_17 IEN104650 SMA Solar Technology AG keps ior Hamm PERTE In order to show the display messages from the initialization phase again during SMA Solar Technology AG Commissioning 6 3 Self Test in accordance with DK 5940 Ed 2 2 applies to Italy only 6 3 1 Starting the Self Test by Tapping You can start testing the disconnection times by tapping on the enclosure lid Prerequisite here is that the country configuration of the inverter has been set to Italy IT DK5940 or trimmed Proceed as f
36. ity operator if necessary e If the grid frequency is within the tolerance range yet Fac Bfr Fac Srr or FacFast faults are still being displayed contact the SMA Serviceline Imax Overcurrent on the AC side This fault code is displayed if the current in avercurrent the AC grid is larger than specified Corrective measures e Check the system design and grid conditions K1 Close Fault during relay test K1 Open Corrective measures e Contact the SMA Serviceline if this problem occurs often or several times in succession MSD FAC Internal measurement comparison fault or hardware defect MSD VAC Corrective measures MSD Timeout Ifthis fault occurs often contact the SMA Serviceline Offset The Offset operating condition is a normal operating condition that occurs prior to grid monitoring If Offset is displayed as an error then there is a disturbance in the data logging Corrective measures Ifthis fault occurs often contact the SMA Serviceline Installation Guide B12_17 IEN104650 53 Failure Search SMA Solar Technology AG Message Description and corrective measure Riso The electrical insulation between the PV plant and ground is faulty The resistance between the DC plus and or DC minus connection and ground is outside the defined limit range Corrective measures e Check the plant insulation e Check the plant for ground faults as described in section 9 3 1 Checkin
37. l All pole AC disconnection unit Automatic disconnection device SMA Grid Guard 2 1 double design Communication Interfaces Bluetooth Optional Radio Optional RS485 galvanically isolated Optional 66 SB12_17 IEN104650 Installation Guide SMA Solar Technology AG Technical Data Electronic Solar Switch Electrical service life in the event of a short circuit A minimum of 50 switching operations with a nominal current of 35 A Maximum switching current 35 A Maximum switching voltage 800 V Maximum PV power 12 kw Protection rating when plugged IP65 Protection rating when unplugged IP21 Efficiency 98 Vpy 180 V DC 92 Vpy 250V DC z 91 gel Vpy 300 V DC gt 90 89 94 3 92 ce 90 88 86 a Sunny Boy 1700 I 500 1000 1500 1700 Pic W Peak efficiency Nesey 93 5 European efficiency NEU 91 8 Installation Guide B12_17 IEN104650 67 Accessories 12 Accessories SMA Solar Technology AG You will find the corresponding accessories and replacement parts for your product In the following overview If required you can order these from SMA Solar Technology AG or your dealer Description Electronic Solar Switch Brief description ESS handle replacement part SMA order number ESS HANDLE 01 Also enter the inverter s serial number
38. lar Technology AG SMA Solar Technology AG Electrical Connection 5 2 Connection to the Public Grid AC 5 2 1 Conditions for the AC Connection le Connection requirements of the utility operator l Comply with the connection requirements of your utility operator Cable Sizing The conductor cross sectional area should be dimensioned so output losses do not exceed 1 at nominal power The maximum wire lengths relative to the conductor cross section are shown in the following table Conductor cross section Maximum wire length SB 1200 SB 1700 1 5 mm 18m 15m 2 5 mm 30m 22 5 m The conductor cross sectional area required in individual cases depends on the following factors among others e Ambient temperature e Routing method e UV resistance e Conduction losses e Valid installation guidelines of the respective country of the installation location Cable Requirements Position Description Value A External diameter 9 mm 17 mm B Conductor cross section max 2 5 mm C Strip insulation 4mm 5 mm Installation Guide SB12_17 IEN104650 21 Electrical Connection SMA Solar Technology AG Load Disconnection Unit You must install a separate line circuit breaker for each inverter in order to ensure that the inverter can be securely disconnected under load The maximum permissible rating is located in section 11 Technical Data page 62 Detailed infor
39. lied is Aubotest shown in the display of the inverter Fac mini da Hi ini aft j EEE us H The frequency limit is increased successively until the shut down threshold is achieved and the inverter disconnects from the grid Once the inverter has disconnected from the grid the display successively shows the following values one after the other Disconnection value Uslore di soglia e Calibration value Hal Laratura 45 iHz e Reaction time Tempo inLeruernto e Present grid frequency When the inverter has carried out the 4 tests it switches to MPP operation mode MPP The original calibration values are then re set and the inverter automatically connects to the grid If you would like to carry out the test again you have to disconnect the inverter in other words you have to disconnect it on the AC and DC sides and then later re activate it You can then restart the self test as described in the following section 6 3 1 Starting the Self Test by Tapping page 39 The inverter begins the test sequence again as described in section 6 3 2 Completion of the Self Test page 39 Installation Guide SB12_17 IEN104650 43 Opening and Closing SMA Solar Technology AG 7 Opening and Closing 7 1 Safety DANGER A Risk of lethal electric shock Observe the following before opening the inverter e Ensure the AC side is not live e Ensure the DC side is not live J NOTICE e Electrostatic discharge
40. ltages 3 Insert an insertion tool into the openings of the terminal contacts 1 The terminal clamps loosen If you do not receive an insertion tool for operating the terminal clamps with your replacement varistors contact SMA Solar Technology AG As an alternative the individual terminal contacts can be operated using a 3 5 mm wide screwdriver Remove the varistor 2 5 Insert new varistor 3 The pole with the small loop crimp must be fitted to terminal A when remounting 6 Close the inverter as described in section 7 3 Closing the Inverter page 47 MI The check and replacement of the varistors is completed Installation Guide SB12_17 IEN104650 59 Decommissioning SMA Solar Technology AG 10 Decommissioning 10 1 Dismantling the Inverter CAUTION Risk of injury due to the heavy weight of the inverter e Remember that the inverter weighs approx 25 kg 1 Open the inverter as described in section 7 2 Opening the Inverter page 44 2 Remove all cables from the inverter Close the inverter with the 4 screws 4 Loosen the lower screw between the inverter und wall mounting bracket 5 Remove the inverter upward from the wall mounting bracket MI The inverter is dismantled 60 B12_17 IEN104650 Installation Guide SMA Solar Technology AG Decommissioning 10 2 Packing the Inverter If possible always pack the inverter in its orig
41. lteration of the threshold value of the ACVigRPro parameter to monitor the voltage quality e If the grid voltage is continually within the acceptable range and this error is still displayed contact the SMA Serviceline Bfr Srr Internal measurement comparison fault or hardware defect Corrective measures Ifthis fault occurs often contact the SMA Serviceline 52 SB12_17 IEN104650 Installation Guide SMA Solar Technology AG Failure Search Message Description and corrective measure EEPROM Transition disturbance while data is being written or read from EEPROM The data is not relevant for safe operation The disturbance has no effect on the performance of the inverter EEPROM dBh EEPROM data is defective the device has switched off because the loss of data has disabled important functions of the inverter Corrective measures e Contact the SMA Serviceline EeRestore One of the duplicate data sets in the EEPROM is defective and has been reconstructed without loss of data e The error message only serves to inform you and has no effect on the performance of the inverter Fac Bfr The grid frequency is no longer within the permissible range Bfr or Srr Facs is an internal message of no relevance for the user FacFas For safety reasons the inverter disconnects itself from the grid Corrective measures e Check the grid connection and contact the util
42. mation and examples for the rating of a line circuit breaker can be found in the Technical Information Line Circuit Breaker in the SMA Solar Technology AG download area at www SMA de en DANGER Danger to life due to fire When more than one inverter is connected to the same line circuit breaker the protective function of the line circuit breaker is no longer guaranteed It can result in a cable fire or the destruction of the inverter e Never connect several inverters to a single line circuit breaker e Comply with the maximum permissible fuse protection of the inverter when selecting the circuit breaker DANGER A Danger to life due to fire When a generator inverter and a consumer are connected to the same line circuit breaker the protective function of the line circuit breaker is no longer guaranteed The current from the inverter and the grid can accumulate to overcurrent which is not detected by the line circuit breaker e Never connect loads between the inverter and the line circuit breaker without protection Always protect consumers separately NOTICE e Damage to the inverter by using screw type fuse elements as a load disconnection unit A screw type fuse element e g D system Diazed or DO system Neozed is not a circuit breaker and may not be used as a load disconnection unit A screw type fuse element is only used as cable protection When disco
43. may not exceed the maximum input voltage AC Output AC nominal power at 230 V AC 50 Hz PAC nom 1200W Maximum AC apparent power SAC max 1 200 VA Nominal AC current IAC nom 5 2A Maximum output current IAC max 6 1A Maximum fuse protection 16A Harmonic distortion of output current at Kiac lt 3 AC THD voltage lt 2 AC power gt 0 5 AC nominal power Nominal AC voltage VAC nom 220 V 230 V 240 V AC voltage range Vac 180V 265 V AC grid frequency Fac nom 50 Hz 60 Hz Operating range at AC grid frequency fic 50 Hz 45 5 Hz 54 5 Hz 60 Hz 55 5 Hz 64 5 Hz Power factor at nominal AC power cos Overvoltage category Ill Test voltage at 50 Hz 1 7 kV Surge testing voltage 4 kV Surge testing voltage with serial interface 6 kV Internal consumption in night mode 0 1 W 62 B12_17 IEN104650 Installation Guide SMA Solar Technology AG Mechanical data Technical Data Width x height x depth 440 mm x 339 mm x 214 mm Weight 23 kg Climatic Conditions Extended temperature range 25 C F60 C Extended humidity range 0 100 Extended air pressure range 79 5 kPa 106 kPa Temperature range 25 C we 70 C Operation temperature range 25 C 60 C Maximum operating altitude above mean sea level 2 000 m according to DIN EN 50178 1998 04 installation type C class 4K4H according to DIN EN
44. ng the test sequence the inverter will not react to tapping The self test changes the upper and lower shutdown thresholds for each protective function on a linear basis with a modification of 0 05 Hz s and 0 05 Vn s for the frequency and voltage monitoring As soon as the actual measurement value is outside the permitted range altered shut down threshold the inverter disconnects itself from the grid In this way the inverter determines the reaction time and checks itself Installation Guide SB12_17 IEN104650 39 Commissioning SMA Solar Technology AG Overvoltage Test The inverter begins with the overvoltage test During the test sequence the voltage limit applied is shown in the Autotest display of the inverter llac mami PET AAL The voltage limit is reduced successively until the shut down threshold is achieved and the inverter disconnects from the grid Once the inverter has disconnected from the grid the display successively shows the following values one after the other Disconnection value e Calibration value Ual barabara 262 BEL e Reaction time Tempo imlLeruerto e Present grid voltage Tensione di reke Hal effa i 40 SB12_17 IEN104650 Installation Guide SMA Solar Technology AG Commissioning Undervoltage Test After the overvoltage test the inverter performs the undervoltage test During the test sequence the current Autot calibration value of the voltage limit applied is shown in Li
45. nnecting under load using a screw type fuse element the inverter can be damaged e Use only a load disconnecting switch or a line circuit breaker as a load disconnecting unit 22 B12_17 IEN104650 Installation Guide SMA Solar Technology AG Electrical Connection 5 2 2 Connecting the Inverter to the Public Grid AC Overview AC connection socket Object Description Socket element Threaded sleeve Sealing ring PG13 5 Fastening case PG13 5 Pressure screw for PG 13 5 for a cable diameter between 9 mm 13 5 mm Cable gland PG 16 for a cable diameter between 13 5 and 17 mm Procedure Choose an appropriate screw fitting for the AC cable Check the grid voltage and compare with Vac nom on the type label The exact operating range of the inverter is specified in the operating parameters The corresponding document is located in the download area at www SMA de en in the Technical Description category of the respective inverter Switch off the line circuit breaker secure against reconnection and make sure no voltage is present Strip approx 30 mm from the AC cable 30mm p app Shorten L and N by 5 mm Strip the wires of the cable by 4 to 5 mm Installation Guide SB12_17 IEN104650 23 Electrical Connection SMA Solar Technology AG 11 12 24 Pass the pressure screw and or cable gland and socket tube over the AC cable Size used Procedure PG1
46. ollows for checking the disconnection times 1 Connect the PV generator with the inverter The inverter can only initialize if the PV generator produces enough power It is therefore not possible to test the disconnection times at night 2 Connect the inverter on the AC side For this you have to create the AC connection AC plug or direct connection and or switch on the line circuit breaker of the grid cable fuse or automatic circuit breaker 3 The inverter is now in the initialization phase i e all 3 LEDs are glowing at the same time Start the self test immediately after all 3 LEDS have gone out by tapping once on the display of the inverter 4 The question on whether you would like to start the test sequence appears in the display Tap on the Avvio Autotest display again within 30 seconds in order to confirm the question Once you have started the test sequence the inverter checks the disconnection times for overvoltage undervoltage maximum frequency and minimum frequency one after the other During the tests the inverter shows the values in the display which are described in section 6 3 2 Completion of the Self Test page 39 6 3 2 Completion of the Self Test Note the values which are displayed during the self test These values must be entered into a test protocol The test results of the individual tests are displayed 3 times one after the other The respective display message is displayed for 10 seconds Duri
47. on the right side of the enclosure The serial number Serial No and the type Type Model of the product as well as device specific characteristics are specified on the type label 14 SB12_17 IEN104650 Installation Guide SMA Solar Technology AG Mounting the Device 4 Mounting the Device 4 1 Safety DANGER Danger to life due to fire or explosion Despite careful construction electrical devices can cause fires Do not mount the inverter on flammable construction materials Do not mount the inverter in areas where highly flammable materials are stored e Do not mount the inverter in areas with a risk of explosion CAUTION Danger of burn injuries due to hot enclosure parts e Mount the inverter in such a way that the enclosure cannot be touched inadvertently CAUTION Risk of injury due to the heavy weight of the inverter e Take the inverter s weight of approx 25 kg into account for mounting 4 2 Selecting the Mounting Location Consider the following points when selecting where to install e The installation method and mounting location must be suitable for the inverter s weight and dimensions see section 11 Technical Data page 62 e Mount on a solid surface e The mounting location must at all times be clear and have safe access without the use of additional aids such as scaffolding or lifting platforms Any possible service actions are otherwise limited max 45
48. otes on this Manual SMA Solar Technology AG 1 4 Symbols Used The following types of safety precautions and general information are used in this manual f DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury f CAUTION CAUTION indicates a hazardous situation which if not avoided could result in minor or moderate injury A N NOTICE iS NOTICE indicates a situation that can result in property damage if not avoided e Information Information provides tips that are valuable for the optimal installation and operation of your product t J M This symbol indicates the result of an action 8 SB12_17 IEN104650 Installation Guide SMA Solar Technology AG Safety 2 Safety 2 1 Appropriate Usage The Sunny Boy is a PV inverter which converts the DC current of the PV generator to AC current and feeds it into the public grid Principle of a PV plant with this Sunny Boy Sunny Boy PV modules Distribution Public grid Va The Sunny Boy may only be operated with PV generators modules and cabling of protection class II Do not connect any sources of energy other than PV modules to the Sunny Boy When designing the PV system ensure that the values comply with the permitted operating range of all com
49. part Declamp the clamping clip Use a screwdriver with a width of 3 5 mm Remove the cable Se I The cable is now removed from the DC plug connector Installation Guide SB12_17 IEN104650 31 Electrical Connection SMA Solar Technology AG 5 4 4 Connecting the PV Generator DC AA DANGER Danger to life due to high voltages in the inverter e Before connecting the PV generator ensure that the line circuit breaker is switched off i NOTICE o Excessive voltages can destroy the measuring device e Only use measuring devices with a DC input voltage range up to at least 1 000 V 1 Disconnect the line circuit breaker and secure against re connection 2 Pull the Electronic Solar Switch downward slightly ina toward the wall 3 Check the connection cables of the PV modules for correct polarity and that the maximum input voltage of the inverter is not exceeded At an ambient temperature above 10 C the open circuit voltage of the PV modules must not be more than 90 of the maximum inverter input voltage Otherwise check the system design and the PV module connection If this is not done the maximum inverter input voltage can be exceeded at low temperatures J NOTICE Exceeding the maximum input voltage can destroy the inverter If the voltage of the PV modules exceeds the maximum input voltage of the inverter it can be destroyed by the overvoltage All warranty claims be
50. plies to SB 1200 IT SB 1700 IT does not apply to national standard deviations of EN 50438 Firmware version 3 06 and higher SMA Solar Technology AG can preset special grid parameters for other countries installation locations according to customer request after evaluation by SMA Solar Technology AG You can make later modifications yourself by changing software parameters with respective communication products e g Sunny Data Control or Sunny Explorer see section 5 6 Setting the Grid and Country Parameters page 35 To change grid relevant parameters you need a personal access code the so called SMA Grid Guard Code The application form for the personal access code is located in the download area at www SMA de en in the Certificate category for each inverter 10 SB12_17 IEN104650 Installation Guide SMA Solar Technology AG Safety 2 2 Safety Precautions DANGER Danger to life due to high voltages in the inverter e All work on the inverter may be carried out by qualified personnel only e The appliance is not to be used by children or persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction e Children should be supervised to ensure that they do not play with the appliance DANGER Danger of burn injuries due to hot enclosure parts e Do not touch enclosure during operation e Only touch the lid durin
51. ponents at all times The free design program Sunny Design www SMA de en SunnyDesign will assist you The manufacturer of the PV modules must have approved the modules for use with this Sunny Boy device You must also ensure that all measures recommended by the module manufacturer for long term maintenance of the module properties are taken see also Technical Information Module Technology in the download area of www SMA de en Do not use the Sunny Boy for purposes other than those described here Alternative uses modifications to the Sunny Boy or the installation of components not expressly recommended or sold by SMA Solar Technology AG void the warranty claims and operation permission Installation Guide SB12_17 IEN104650 9 Safety SMA Solar Technology AG Certified Countries The Sunny Boy 1200 1700 with according configuration fulfill the requirements specified in the following standards and directives dated 12 2010 SB 1200 SB 1700 AS4777 2005 AS4777 2005 e C10 C11 05 2009 e C10 C11 05 2009 e CER 06 190 10 2006 e CER 06 190 10 2006 DK 5940 Ed 2 2 02 2006 DK 5940 Ed 2 2 02 2006 e EN 50438 2008 e EN 50438 2008 e G83 1 1 2008 e G83 1 1 2008 e IEEE929 EEE929 PPC 2006 PPC 2006 PPDS 2009 PPDS 2009 e RD 1663 2000 2000 RD 1663 2000 2000 e RD 1663 661 RD 1663 661 e VDE 0126 1 1 02 2006 e VDE 0126 1 1 02 2006 e UTE C15 712 1 e UTECIS712 1 On request only ap
52. s can damage the inverter Internal components of the inverter can be irreparably damaged by electrostatic discharge e Ground yourself before touching a component 7 2 Opening the Inverter 1 Disconnect the line circuit breaker and secure against re connection 2 Pull the Electronic Solar Switch downwards slightly towards the wall 3 Using a current probe ensure that there is no current to all DC cables MI If there is a current present check the installation SI 44 B12_17 IEN104650 Installation Guide SMA Solar Technology AG Opening and Closing 4 Unlock all the DC plug connectors Use a screwdriver with a width of 3 5 mm Insert a screwdriver into one of the side slits 1 Disconnect the DC plug connectors 2 DANGER Danger to life due to unsafe disconnection from the PV generator A secure separation from the PV generator is only guaranteed after pulling off the Electronic Solar Switch and all DC plug connectors Remove all DC plug connectors to completely disconnect the PV generator from the inverter To 5 Pull out the AC plug m 8 Installation Guide B12_17 IEN104650 45 Opening and Closing SMA Solar Technology AG 6 Check whether all LEDs and the display have gone out DANGER Danger to life due to high voltages in the inverter
53. tion of the varistors as described below Open the inverter as described in section 7 2 Opening the Inverter page 44 2 With the aid of a multimeter determine for both varistors in the installed state whether a conductive connection exists between connectors B and C Result MI There is a conducting connection There is probably a different fault in the inverter Action e Contact the SMA Serviceline see section 13 Contact page 69 58 SB12_17 IEN104650 Installation Guide SMA Solar Technology AG Failure Search Result Action M There is no conducting The respective varistor is not working and must be connection replaced Varistor failure is generally due to influences which affect all varistors similarly temperature age induced overvoltage SMA Solar Technology AG recommends that you replace both varistors The varistors are specially manufactured for use in the inverter and are not commercially available They must be ordered directly from SMA Solar Technology AG see section 12 Accessories page 68 e To replace the varistors proceed to step 3 NOTICE Destruction of the inverter due to overvoltage If varistors are missing the inverter is no longer protected against overvoltages e Replacement varistors should be obtained as soon as possible e Do not operate the inverter without varistors in plants with a high risk of overvo
54. tor at nominal AC power cos b Overvoltage category Test voltage at 50 Hz 1 7 kV Surge testing voltage 4 kV Surge testing voltage with serial interface 6 kV Internal consumption in night mode 0 1 W Installation Guide B12_17 IEN104650 65 Technical Data Mechanical data SMA Solar Technology AG Width x height x depth 440 mm x 339 mm x 214 mm Weight 25 kg Climatic Conditions Extended temperature range 25 C F60 C Extended humidity range 0 100 Extended air pressure range 79 5 kPa 106 kPa Temperature range 25 C we 70 C Operation temperature range 25 C 60 C Maximum operating altitude above mean sea level 2 000 m according to DIN EN 50178 1998 04 installation type C class 4K4H according to DIN EN 50178 1998 04 transport type E class 2K3 Features Topology LF transformer General data Protection rating according to DIN EN 60529 IP65 Protection class Noise emission typical lt 46 dB A Protective equipment All pole DC switch disconnector Electronic Solar Switch DC plug system SUNCLIX DC overvoltage protection Thermally monitored varistors Personal protection R gt 1 MQ ISO Insulation monitoring Pole confusion protection Short circuit diode AC short circuit protection Current contro