Home

Ultracom hxi - Online Boilers

image

Contents

1. Ultracom hx High Efficiency Condensing Boilers Instructions for Use Tobeleftwiththe user ee S o www glow worm co uk GAS LEAK OR FAULT Turn off the gas emergency control valve immediately Eliminate all sources of ignition i e smoking blowlamps hot air guns etc Do not operate electrical lights or switches either on or off Open all doors and windows ventilate the area METAL PARTS This boiler contains metal parts components and care should be taken when handling and cleaning with particular regard to edges SEALED COMPONENTS Under no circumstances must the user interfere with or adjust sealed parts Glow worm service call 01773 828100 Technical helpline 01773 828300 General and Sales enguiries Tel 01773 824639 Fax 01773 820569 EN Benchmark The code of practice for the installation commissioning amp servicing of gas central heating 2 www glow worm co uk M Glow worm Ultracom 12hxi G C No 41 019 01 a gt Glow worm U Ultracom 15hxi G C No 41 019 02 a N Glow worm Ultracom 18hxi G C No 41 019 03 Glow worm U Ultracom 24hxi G C No 41 019 04 C N Glow worm U Ultracom 30hxi G C No 41 019 05 gt Glow worm U Ultracom 38hxi G C No 41 019 06 www glow worm co uk 13204
2. P Contents Page Important Information Boiler Design and Clearances Boiler Safety Devices Servicing Maintenance and Spare Parts O N O A User Control Panel o Lighting the Boiler Adjusting Temperature 11 Fault Finding 11 These instructions are an integral part of the boiler and must to comply with the current issue of the Gas Safety Installation and Use Regulations be left with the user Please read these instructions and follow them carefully for the safe and economical use of your boiler www glow worm co uk m HEM Important Information Gas Safety Installation and Use Regulations In your own interests and that of safety itis the Law that ALL gas appliances have been installed by a competent person in accordance with the current issue of these regulations Gas Category This boiler is for use only on G20 natural gas but can be converted for use on G31 propane Electrical Connection The boiler MUST be earthed The boiler MUST be connected to a permanent 230V ac 50Hz supply fused at 3A Connection of the whole electrical system of the boiler including any heating controls to the electrical supply must be through one common isolator The colours of three core flexible cable are blue neutral brown live green and yellow earth Testing and Certification This boiler is certificated to the current issue of EN 483 for performance and safety It is importan
3. ady reached 359C The burner will only activate if the boiler temperature does not reach 10 C after 30 minutes or at any time if the temperature drops to 5 C The burner will switch off when the temperature reaches 35 C NOTE Any other exposed areas of the system should be protected by a separate frost thermostat Condensate Drain Blockage Asasafety feature the boiler will stop working if the condensate drain becomes blocked During freezing conditions this may be due to the forming of ice in the condense drain external to the house Release anice blockage by the use of warmcloths on the pipe The boiler should then restart Contact your Installation Servicing company or Glow worm service if the fault persists www glow worm co uk 7 Servicing Maintenance and Spare Parts General Note Servicing maintenance should be carried outby a competent person in accordance with the rules in force in the countries of destination If this boiler is installed in a rented property in the UK there is a duty of care imposed on the owner of the property by the current issue of the Gas Safety Installation and Use Regulations Section 35 Servicing To ensure the continued efficient and safe operation of the boiler it is recommended that it is checked and serviced at regular intervals The frequency of servicing will depend upon the site conditions and usage but in general once a year should be enough To obtain service p
4. lease call your installer or Glow worm s own service organisation using the telephone number on the inside front cover of this booklet Cleaning The boiler casing can be cleaned using a mild liquid detergent with a damp cloth then a dry cloth to polish Do notuse any form of abrasive or solvent cleaner as you may damage the paintwork Frost Protection If the mains electricity and gas services are to be turned off for any long periods during severe weather it is recommended that the whole system including the boiler should be drained to avoid the risk of freezing Spare Parts REMEMBER When replacing a part on this boiler use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Glow worm If replacement parts are required contact Glow worm s own service organisation using the telephone number on the inside front cover of this booklet Please quote the name and model of the boiler The name and model badge is on the front case If in doubt seek advice from the local gas company or Glow worm s own service organisation using the telephone number on the inside front cover of this booklet 8 www glow worm co uk mm EES oe EME User Control Panel General Description The User Control panel consists of three toggle buttons a reset button and display which will i
5. low worm co uk Adjusting Temperature Central Heating The temperature is factory preset to the minimum 389C but can be adjusted to a maximum of 829C as reguired refer to diagram 5 Central Heating ADVANCE m Press the or once the current temperature will be displayed flashing W Sone n ADVANCE Press or to increase or decrease the temperature The temperature setting will automatically save after 5 seconds Diagram 5 m HEM Fault Finding Appliance fails to light The LCD will display a flashing F and code number press the reset button on the control panel see diagram 2 If any fault persists contact your installer service provider or Glow worm Service using the telephone number on the inside front cover of this booklet Electrical Supply Failure The boiler will not work without an electrical supply and normal operation of the boiler should resume when the electrical supply is restored If the boiler does not resume normal operation check the external controls it may be necessary to reset the boiler refer to the section Boiler Safety Devices www glow worm co uk 11 0020020824 02 11 06 0020020824 Because of our constant endeavour for improvement details may vary slightly from those shown in these instructions Glow worm Nottingham Road Belper Derbyshire DE56 1JT
6. m flue terminal Like all condensing boilers it will produce a plume of condensation from the flue terminal in cool weather This is due to the high efficiency and hence low flue gas temperature of the boiler It is normal and not a fault indication Compartment or Cupboard Installations Ventilation is not reguired for compartment or cupboard installations Do not use the compartment or cupboard for storage CLEARANCES from casing panels 200 A removable compartment door can be placed a minimum 5mm in front of the appliance A clearance of 600mm is required from a fixed surface A 5mm to a non permanent surface 20mm to a permanent surface Diagram 1 6 www glow worm co uk m HEM Boiler Safety Devices Boiler Shutdown The boiler software is designed to recognise the potential for an overheat lockout and will shutdown before this happens To restart the boiler press the reset button see diagram 2 If the boiler fails to resume normal operation and all external controls are calling for heat then call your Installation Servicing company or Glow worm service Frost Protection With the gas and electric supplies ON and irrespective of any room thermostat setting the integral frost protection device will operate the pump when the temperature of the boiler water falls below 89C The pump will stop after 10 minutes if the temperature is higher than 109C or has alre
7. ndicate with symbols the status of the boiler refer to diagram 2 ADVANCE EHE Poo TOGGLE BUTTON LCD RESET NOT CH TEMPERATURE MODE and PROG DISPLAY BUTTON USED ADJUSTMENT SYMBOLS DISPLAYED ON THE LCD AND DESCRIPTIONS Central Heating Function Min burner display Appliance OFF Temperature Max burner display Glow worm control Optional Control Panel Diagram 2 www glow worm co uk 9 NT Ts Lighting the Boiler Initial Lighting 2 Select your required function refer to diagram 2 press MODE repeatedly to scroll through your options and select one of the following Central heating Wi Boiler functions ALL switched off FF Remove the cover plate see diagram 3 Check that the gas service cock on the appliance is open Note If you are in any doubt about the boiler being filled with water contact your installer or Glow worm s own service organisation using the telephone number on the inside front cover of this booklet Do not operate the boiler without water 3 Turn ON your external controls and select the room temperature required 1 With no demand from any external controls switch on the electrical supply to the boiler The boiler will operate automatically Note The display will indicate the Heating system water temperature or a fault code see section Fault Finding P GAS SERVICE COCK A shown open Diagram 3 Diagram 4 COVER PLATE 10 www g
8. t that no alteration is made to the boiler unless approved in writing by Glow worm Any alteration not approved by Glow worm could invalidate the certification boiler warranty and may also infringe the current issue of the statutory reguirements CE Mark This boiler meets the requirements of Statutory Instrument No 3083 of the Boiler Efficiency Regulations and therefore is deemed to meet the requirements of Directive 92 42 EEC on the efficiency requirements for new hot water boilers fired with liquid or gaseous fuels Type test for purposes of Regulation 5 certified by Notified body 0087 Product production certified by Notified body 0086 The CE mark on this appliance shows compliance with 1 Directive 90 396 EEC on the approximation of the laws of the Member States relating to appliances burning gaseous fuels 2 Directive 73 23 EEC on the harmonisation of the Laws of the Member States relating to electrical equipment designed for use within certain voltage limits 3 Directive 89 336 EEC on the approximation of the Laws of the Member States relating to electromagnetic compatibility www glow worm co uk 5 1 O 8 mm EES Boiler Design and Clearances Description These boilers are designed to provide central heating from a fully pumped open vented or sealed water system and domestic hot water using a fully indirect cylinder Once the controls are set the boiler operates automatically Pluming fro