In Vivo Calibration for ManoScan Catheters

image

Contents

1. Repeat the above steps again e It must display Calibrated in green at the top left of the screen 11 Follow the Guided Protocol Instructions and pop up commands e This feature leads you through the in vivo calibration step by step Note DO NOT JUMP AHEAD OF THE GUIDED PROTOCOL INSTRUCTIONS 12 Select Finish when prompted 13 Select OK to close the Utilities window 14 Close the ManoScan Acquisition software 15 Allow the catheter to cool down to room temperature approximately 10 minutes orior to applying a ManoShield sanitary sheath and prior to performing a study 16 To oroceed with oerfor y ing a study open the ManoScan Acquisition GI EN VW IMAGING software select the connected catheter and select Start at the top right side of the toolbar GlyEN asia the scope of GI IMAGING givenimaging com The risks of catheter insertion into the nasal passage associated with ManoScan ESO high resolution manometry include discomfort nasal pain minor bleeding runny nose throat discomfort irregular heartbeat with dizziness and perforation In rare instances the catheter may be misdirected into the trachea causing coughing or choking or the catheter may shift up or down causing false results The risks of ManoScan AR high resolution manometry include perforation or bleeding of the intestinal wall Patients with previous rectal surgery bowel inflammation or bowel obstruction may have a higher risk for iat
2. Quick Reference Guide W _____ ManoScan high resolution manometry In Vivo Calibration for ManoScan Catheter Products In vivo calibration establishes channel compensation for transition from ambient temperature to body temperature and the aqueous in vivo environment In vivo calibration should be performed at least once a week to promote a weekly routine J Turn on all equipment Modules should be turned on before the computer 2 Connect the red and blue catheter connectors to the A100 A120 module or the large white connector if using the A200 module or the larger connectors to the A300 3D module if using 3D catheter Note ManoShield AR 3D must be used when performing in vivo calibration on AR 3D probe 3 Double click on the appropriate ManoScan Acquisition desktop icon 4 Select the catheter serial number connected to the system if prompted 5 Click Calibration on the toolbar 6 Pressure calibrate the catheter by pressing the Start button e The Close button bottom left of Calibration window will change from Cancel to OK after pressure calibration is complete 7 Click the OK button 8 Click Calibration on the toolbar again 9 Click the Utilities button bottom right of Calibration window 10 Select Calibration In vivo from the Utilities window e If the Calibration In vivo button is grayed out and not selectable it means the catheter has not been successfully pressure calibrated
3. rogenic bowel perforation Medical endoscopic or surgical intervention may be necessary to address any of these complications should they occur These systems are not compatible for use in an MRI magnetic field Please refer to the respective product user manual or givenimaging com for detailed information Copyright 2001 2013 Given Imaging Ltd GIVEN GIVEN amp Design PILLCAM PILLCAM amp Logo RAPID RAPID ACCESS BRAVO BRAVO PH SYSTEM DIGITRAPPER MANOSCAN MANOSHIELD MANOVIEW GASTROTRAC GEROFLEX VERSAFLEX ACCUTRAC ACCUVIEW POLYGRAF ID SMARTPILL MOTILIGI SMARTBAR and THE MEASURE OF GI HEALTH are Trademarks and or Registered Trademarks of Given Imaging Ltd its subsidiaries and or affiliates in the United States and or other countries All other company or product names are the trademarks or registered trademarks of their respective holders All rights not expressly granted are reserved 5 001 869

Download Pdf Manuals

image

Related Search

Related Contents

38SD822V OPERATING INSTRUCTIONS MODE D  SaliPen User Manual  Audiovox VOD85 Warranty Card  Global Field Action Reportability Procedure  Milwaukee worklight User's Manual  Covering Sampler component functionality in  USER MANUAL - Telefunken    Manhattan 161633  Brochure technique FK-EU  

Copyright © All rights reserved.
Failed to retrieve file